Loading...
HomeMy WebLinkAboutCOMAM_IN_8123_131st & Hazel Dell_Exp_Bid Permit Set Signed PROJECT CONTACTS VICINITY PLAN SITE AND OCCUPANCY INDEX OF SHEETS GENERAL NOTES PROJECT DESCRIPTION: PROGRAMKIRBY MEINDL EXPANSION SHEETSHEET TITLE GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING 1. MANAGER:564 W. RANDOLPH ST. SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS SITE 3RD FLOOR BUILDING HEIGHT:1 STORY SURVEYOR AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS GENERAL CHICAGO, IL 60661 PRIOR TO BIDDING OR CONSTRUCTION. (312) 380-3736 G-0001GENERAL INFORMATION 2822 SF BUILDING AREA: KMEINDL@STARBUCKS.COM G-0002LIFE SAFETY PLAN GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION 2. COMMERCIAL BUILDING USE: G-0003ACCESSIBILITY GUIDELINES MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES DESIGNER:LISA MACEDA PRIOR TO BIDDING OR CONSTRUCTION. G-0004SCOPE OF WORK PLAN 564 W. RANDOLPH ST. B-3 ZONING: G-0005LEED EDUCATIONAL 3RD FLOOR R ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, 3. SIGNAGE PLAN CHICAGO, IL 60661 COFFEE SHOP TYPE OF USE: COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. G-0006PERSPECTIVE VIEWS EMACEDA@STARBUCKS.COM C 2017 STARBUCKS COFFEE COMPANY A-2 ASSEMBLY G-0010CONSTRUCTION TYPE OF OCCUPANCY: GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES. 4. CONSTRUCTION EDWARD ABRAM SPECIFICATIONS STARBUCKS COFFEE MANAGER:1402 NORTH CAPITOL LAKE RETAIL: 137 SF / 30 =5 G-0011CONSTRUCTION OCCUPANCY LOAD: GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES 5. SUITE 200 CAFE/SEATING: 1212 SF / 15 =81 SPECIFICATIONS REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER COMPANY INDIANAPOLIS, IN 46202 BEVERAGE/PREP: 408 SF / 200 = 2 OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL G-0012CONSTRUCTION (901) 598-8306 CELL RESTROOM/STORAGE: 792 SF / 300 =3 2401 UTAH AVENUE SOUTH DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED SPECIFICATIONS EABRAM@STARBUCKS.COM TOTAL OCCUPANCY = 91 OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. SEATTLE, WASHINGTON 98134 G-0013CONSTRUCTION DO NOT SCALE DRAWINGS. EXTERIOR SEASONAL SPECIFICATIONS (206) 318-1575 ARCHITECT OF DONALD RETHMAN 18 SEATING: RECORD:DESIGN FORUM ARCHITECTS GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS,FLOORS, 6. THESE DRAWINGS AND SPECIFICATIONS ARE 700 W.PETE ROSE WAY ARCHITECTURAL CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME EXIT CAPACITY: CONFIDENTIAL AND SHALL REMAIN THE SOLE SUITE 460-5TH FLOOR, EXIT 1: 42" WIDE A-1000DEMOLITION SITE PLAN DAMAGED DURING THE COURSE OF THE WORK. PROPERTY OF STARBUCKS CORPORATION, CINCINNATI, OH 45203 EXIT 1: 36" WIDE A-1001ARCHITECTURAL SITE PLAN WHICH IS THE OWNER OF THE COPYRIGHT IN (513) 975-4229 OFFICE EXIT 2: 36" WIDE THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE 7. A-1002ENLARGED EXTERIOR PLAN THIS WORK. THEY SHALL NOT BE DON.RETHMAN@INTERBRAND.COM TOTAL EXIT WIDTH PROVIDED: 114 IN PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS PRIOR TO A-1003DRIVE THRU DETAILS REPRODUCED (IN WHOLE OR IN PART), SHARED 0.2 X 91 OCCUPANTS = 18.2 IN REQUIRED INSTALLATION OF SUCH SYSTEMS. WITH THIRD PARTIES OR USED IN ANY MANNER PROJECT PETER CHEETHAM A-1004SITE DETAILS TRAVEL DISTANCE: ON OTHER PROJECTS OR EXTENSIONS TO THIS MANAGER:DESIGN FORUM ARCHITECTS ALLOWED TRAVEL DISTANCE: 200'-0" A-2001EXTERIOR ELEVATIONS GENERAL CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND 8. PROJECT WITHOUT THE PRIOR WRITTEN 700 W.PETE ROSE WAY ACTUAL TRAVEL DISTANCE: 82'-2" DOCUMENT ALL CHANGES DURING CONSTRUCTION. THIS SET SHALL BE A PART OF CONSENT OF STARBUCKS CORPORATION. SUITE 460-5TH FLOOR, 82'-2" < 200'-0" THEREFORE COMPLIES THE GENERAL CONTRACTORÓS ÐSTORE CLOSE-OUT PACKAGEÑ AS DESCRIBED IN INTERIORS THESE DRAWINGS AND SPECIFICATIONS ARE CINCINNATI, OH 45203 THE CONSTRUCTION MANAGEMENT AGREEMENT. I-1101DEMOLITION FLOOR PLAN INTENDED TO EXPRESS DESIGN INTENT FOR A (513) 975-4225 OFFICE PROTOTYPICAL STARBUCKS STORE (WHICH IS PETER.CHEETHAM@INTERBRAND.COM I-1102DEMOLITION CEILING PLAN MIN. NUMBER OF EXITS REQUIRED:2 NUMBER OF EXITS: GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF 9. SUBJECT TO CHANGE AT ANYTIME) AND DO NUMBER OF EXITS PROVIDED:3 I-1103FLOOR PLAN MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS NOT REFLECT ACTUAL SITE CONDITIONS. MEP CONSULTANT TIM RABERDING . I-1103.1DOOR AND WINDOW DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. REFER TO NEITHER PARTY SHALL HAVE ANY OBLIGATION OF RECORD:DESIGN FORUM ENGINEERING SCHEDULES CONSTRUCTION MANAGEMENT AGREEMENT FOR METHODS AND LEAD TIMES. NOR LIABILITY TO THE OTHER (EXCEPT STATED 700 W.PETE ROSE WAY N I-1104PENETRATION PLAN ABOVE) UNTIL A WRITTEN AGREEMENT IS SUITE 460-5TH FLOOR, RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS 10. I-1105FF AND E PLAN FULLYEXECUTEDBYBOTHPARTIES CINCINNATI, OH 45203 ROOM SCHEDULE SITE IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED I-1105.1FF AND E SCHEDULES (513) 975-4209 "RESPONSIBILITY". TIM.RABERDING@INTERBRAND.COM I-1106CASEWORK PLANSTARBUCKS TEMPLATE VERSION i2017.08.25 NAMEAREA I-1106.1CASEWORK SCHEDULE FOR THE PURPOSE OF THE DOCUMENTS, TO ÐINSTALLÑ, SHALL MEAN TO PROVIDE 11. ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL I-1106.2ENLARGED BAR PLAN - BEVERAGE PREP.408 SF EQUIPMENT CONNECTIONS, PLUMBING CONNECTIONS, AND OTHER ITEMS REQUIRED FOR A Design Forum CAFE/SEATING1212 SF COMPLETE AND OPERATION INSTALLATION, UNLESS OTHERWISE NOTED. I-1106.3ENLARGED BAR PLAN - RETAIL137 SF CABINETS RR/WORKROOM783 SF ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS DESIGN Architects Inc. 12. I-1107REFLECTED CEILING PLAN MANAGER. UNOCCUPIABLE AREA273 SF 700 W. Pete Rose Way, Suite 460Donald J. Rethman I-1107.1DIMENSIONED CEILING AND Cincinnati, OH 45203Architect In Charge GRAND TOTAL2813 SF LIGHTING PLAN Tel: (513) 421-2210License: AR19700147 REFER TO ITEM CUTSHEETS FOR ADDITIONAL INFORMATION. 13. I-1109FLOOR FINISH PLAN I-1111WALL FINISH PLAN Design Forum I-2101INTERIOR ELEVATIONS APPLICABLE BUILDING CODESFIXTURE CALCULATION ABBREVIATIONS I-2102INTERIOR ELEVATIONS 3PLTHIRD PARTY LOGISTICSLEEDLEADERSHIP IN ENERGY AND I-2103INTERIOR ELEVATIONS ARCHITECTURAL SYMBOL LEGEND MIN Number of Plumbing Fixtures: Engineering 2014 INDIANA BUILDING CODE, ENVIRONMENTAL DESIGN I-2104INTERIOR ELEVATIONS 2012 INDIANA PLUMBING CODE, 62 Indoor Seats Occupant Load : 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE A/CAIR CONDITIONINGLLLANDLORD Cincinnati, OH 45203Professional Engineer I-4102ENLARGED RESTROOM2014 INDIANA ELECTRICAL CODE, 18 Outdoor Seasonal Seats ACTACOUSTICAL CEILING TILE License: PE10504904 Tel: (513) 421-2210 PLAN 2014 INDIANA MECHANICAL CODE, 70 Total Seats ADJADJUSTABLEMAXMAXIMUM 2014 INDIANA FIRE CODE, I-4102.1ENLARGED RESTROOM AFFABOVE FINISHED FLOORMEP"MECHANICAL, ELECTRICAL, 2010 INDIANA FIRE CODE, ELEVATIONSMen: 35 Women: 35 NORTH ARROWSWXXXXPAINT TAG Distribution: AMPAMPEREAND PLUMBING" N 2010 INDIANA ENERGY CONSERVATION CODE. I-5001CONSTRUCTION DETAILS ARCHARCHITECTMFRMANUFACTURER 2012 INDIANA PLUMBING CODE: MINMINIMUM I-5002CONSTRUCTION DETAILS XXXXXXDESIGN ID TAG BOHBACK OF HOUSEMTL METAL I-5003RESTROOM AND CODE CLASSIFICATION WORKROOM DETAIL Men Women CABCABINETNICNOT IN CONTRACT A. OCCUPANCY GROUP:A-2 ASSEMBLY EXT ELEVATION 1 Per 75 Occupants 1 Per 75 Occupants Water Closets I-5004FLOOR FINISH DETAILS DXXXXXDOOR TAG CLCENTER LINENLNIGHT LIGHT B. CONSTRUCTION CLASSIFICATION TYPE: II-B, NON SPRINKLERED I-5005WALL FINISH DETAILS CLGCEILINGNTSNOT TO SCALE C. AUTOMATIC FIRE SUPPRESSION 1 Per 200 Occupants 1 Per 200 Occupants Lavatories I-5006CASEWORK DETAILS CMCONSTRUCTION MANAGER SYSTEM INSTALLED:NO CTRCENTEROCON CENTER D. ZONING:B-3 I-5007CASEWORK DETAILS WINDOW TAG WXXXXX 0 N/A Urinals CX COMMISSIONINGODOUTSIDE DIAMETER I-5008CASEWORK DETAILS INT ELEVATION 11/01/17 09/01/17 Women Men CXACOMMISSIONING AGENTOF/CIOWNER FURNISHED/ I-5009CASEWORK DETAILS Fixture REQ'D Provided CONC CONCRETECONTRACTOR INSTALLED REQ'D Provided X'-XX" AFFABOVE FINISHED FLOOR I-5010CASEWORK DETAILS OF/OIOWNER FURNISHED/OWNER HEIGHT TAG (IMPERIAL) Water Closets 1111 I-5011CASEWORK DETAILS DEGDEGREEINSTALLED Urinals 00N/AN/A DETDETAIL I-5012CASEWORK DETAILS L Lavatories 1111 SECTION CALLOUT DIADIAMETERPDPRODUCTION DESIGNER I-5013CASEWORK DETAILS XXXX AFFABOVE FINISHED FLOOR Drinking Fountains L Not RequiredNot Required DIMDIMENSIONPLCPLACE HEIGHT TAG (METRIC) I-5014CONNECTION DETAILS Y DMDESIGN MANAGERPMPROJECT MANAGER E I-6001SCHEDULES DNDOWN W X' XX"I-6002SCHEDULES D RRADIUS DIMENSION LINE FROM K EAEACHRCMRENOVATIONS CONSTRUCTION DETAIL CALLOUT FINISH FACE TO FINISH P L ELELEVATIONMANAGER PLUMBING FACE L EQEQUALREFREFERENCE E P-0001PLUMBING NOTES 3 L EXISTEXISTINGREQÒDREQUIRED 3 P-0002PLUMBING SCHEDULES Z EXTEXTERIORREVREVISION E 0 REVISION CLOUD P-1101PLUMBING SUPPLY PLAN RNDROUND A D6 REVISION TAG X P-1102PLUMBING WASTE PLAN FF&E"FURNITURE, FIXTURE, AND 4 L H EQUIPMENT" FIO FURNISHED SBSTARBUCKS P-1103WASTE SCHEMATIC E N AND INSTALLED BY OWNERSCSOLID CORE P-1104GAS PIPING PLAN I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z FLRFLOORSFSQUARE FEET & , DATUM POINT P-5001PLUMBING DETAILS FOHFRONT OF HOUSESHTSHEET A L FTFOOT/FEETSIMSIMILAR T H E MECHANICAL SPECSPECIFICATION S 0 M GGROUNDSQSQUARE M-0001MECHANICAL NOTES 7 1 GCGENERAL CONTRACTOR R M-1101MECHANICAL PLAN 1 TEMPTEMPORARY 3 A M-5001MECHANICAL DETAILS 3 HCHOLLOW CORETYPTYPICAL 1 1C HDWHARDWARE ELECTRICAL HMHOLLOW METALUONUNLESS OTHERWISE NOTED HORIZHORIZONTAL E-0001ELECTRICAL NOTES STORE #:8123 HRHOUR VDVENDOR DIRECT E-1001ELECTRICAL SITE PLAN PROJECT #:25450-048 HTHEIGHTVERTVERTICAL E-1101ELECTRICAL DESIGN PLAN HVAC"HEATING, VENTILATING, AND VIFVERIFY IN FIELD ISSUE DATE: 11/1/17 E-1102LIGHTING DESIGN PLAN AIR CONDITIONING" DESIGNER: LISA MACEDA E-1103ELECTRICAL LOW VOLTAGE R LEED AP: PLAN IDINSIDE DIAMETER PRODUCTION DESIGNER: PETER CHEETHAM E-5001ELECTRICAL DETAILSINTINTERIOR CHECKED BY: E-6001PANELBOARD SCHEDULES Revision Schedule RevDateByDescription PROJECT SCOPE: C:\\Users\\zach.scholl\\Documents\\Starbucks_131st - NEW DT EQUIPMENT - EXPANSION INTO ADJACNET SPACE SHEET TITLE: - NEW FINISHES, EQUIPMENT, AND FIXTURES GENERAL INFORMATION - NEW PARTITIONS NO SCALE SCALE: - DEMO OF ADAJACENT SPACE SHEET NUMBER: - DEMO OF CURRENT SPACE (EXCEPT FOR SOME EQUIPMENT) G-0001 10/31/2017 6:16:36 PM LEGEND: Travel Distance Exit Light (See Reflected Ceiling Plan) Wall Mounted Emergency Light R (See Reflected Ceiling Plan) C 2017 STARBUCKS COFFEE COMPANY ADA Clear Floor Space for Accessibility STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH FLAME SPREAD RATING: SEATTLE, WASHINGTON 98134 (206) 318-1575 Flame spread rating for all proposed interior finishes shall comply with local building code. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, INTERIOR FINISH NOTES: WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 1.Interior wall and ceiling finish materials shall be REPRODUCED (IN WHOLE OR IN PART), SHARED Class C with a flame spread rating less than 200 WITH THIRD PARTIES OR USED IN ANY MANNER and smoke developed less than 450. ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN 2.Floor Coverings in the exit path of all common areas CONSENT OF STARBUCKS CORPORATION. shall meet Class A requirements. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS (R) EMERGENCY FULLYEXECUTEDBYBOTHPARTIES LIGHT (E) ELECTRICAL STARBUCKS TEMPLATE VERSION i2017.08.25 PANEL Design Forum Architects Inc. MEN 700 W. Pete Rose Way, Suite 460Donald J. Rethman RESTROOM Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 TRAVEL Design Forum TRAVEL DISTANCE: 39'- 8" (N) LIGHTED DISTANCE: 37'- 6" EXIT SIGN Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 HALLWAY (R) EMERGENCY 1' - 5"1' - 5" LIGHT ADAADA (E) LIGHTED EXIT SIGN WOMEN 11/01/1709/01/17 RESTROOM 1' - 5" CAFE/SEATING ADA L L TRAVEL Y (E) LIGHTED RETAIL E DISTANCE: 28'- 11" EXIT SIGN W D K (E) ELECTRICAL P L PANELS L E 3 L 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M BEVERAGE 7 1 R 1 PREP. 3 A 3 ADA (E) LIGHTED (N) LIGHTED 1 1C TRAVEL DISTANCE: 82'- 2" EXIT SIGNEXIT SIGN STORE #:8123 PROJECT #:25450-048 1' - 5" ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R PATIO LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM ADA CHECKED BY: Revision Schedule TRAVEL DISTANCE: 45'- 4" RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st WORKROOM SHEET TITLE: LIFE SAFETY PLAN (R) FIRE EXTINGUISHER(N) EMERGENCY 02'4'8' LIGHT 1/4" = 1'-0" SCALE: Scale: 1/4" = 1'-0" SHEET NUMBER: LIFE SAFETY PLAN 1 N Scale: 1/4" = 1'-0" G-0002 10/31/2017 6:16:56 PM NOTE: 30 30 BOTH HIGH AND LOW FOUNTAINS ARE REQUIRED, NO FEWER THAN 50% WHEELCHAIR ACCESSIBLE: OTHERS ARE S S 1 7 U U I TO BE LOCATED AT A STANDERED HEIGHT I 3 1 D D A A R R CONVENIENT TO THOSE WITH DIFFICULTY 48 48 1/4" (6.5MM) MAX. STOOPING. HIGH-LOW FOUNTAINS ARE REQ. WHEN ONLY ONE FOUNTAIN IS R 9 126 17 APPROVED. 247724 107 7 C 2017 STARBUCKS COFFEE COMPANY 17-19 12 MIN36 MIN12 MIN 48 MIN 30 MIN 30 MIN EQUIPMENT NOT TO PACE PERMITTED IN DIMENSIONS OF ADULT-SIZED DIMENSIONS OF ADULT-SIZED EXCEED 17-19 1/4" TO 1/2"2 STARBUCKS COFFEE SHADED AREA FOUNTAIN DEPTH WHEELCHAIR WHEELCHAIR 1 (6.5 TO 13 MM) 27 MAX. COMPANY 36-60 48 MIN 48 MIN 2401 UTAH AVENUE SOUTH 9 MIN 32 MIN 27 MIN 36 MAX 66 SEATTLE, WASHINGTON 98134 EYE LEVEL (206) 318-1575 8 MIN6 MAX CANE TECHNIQUE HANDLE 24 MAX CANE TECHNIQUE ARMREST LAP THESE DRAWINGS AND SPECIFICATIONS ARE 26 18 SEAT CONFIDENTIAL AND SHALL REMAIN THE SOLE SPOUT HEIGHT AND KNEE FREE-STANDING FOUNTAIN BUILT-IN FOUNTAIN OR 2 36 MIN 3630 1/2" MAX. PROPERTY OF STARBUCKS CORPORATION, 1 CLEAR FLOOR SPACE TOE 27 CLEARANCE OR COOLER 19 COOLER 43-51 426 WHICH IS THE OWNER OF THE COPYRIGHT IN 8 W/ PROTRUDING THIS WORK. THEY SHALL NOT BE CHANGES IN LEVEL OBJECTS RAILS REPRODUCED (IN WHOLE OR IN PART), SHARED T-SHAPED SPACE FOR DIMENSIONS OF ADULT-SIZEDDIMENSIONS OF ADULT-SIZED WITH THIRD PARTIES OR USED IN ANY MANNER 180° TURNS ON OTHER PROJECTS OR EXTENSIONS TO THIS WHEELCHAIRWHEELCHAIR PROJECT WITHOUT THE PRIOR WRITTEN SECTION 4.3 ACCESSIBLE ROUTESECTION 4.15 DRINKING FOUNTAINS 2113 CONSENT OF STARBUCKS CORPORATION. SCALE: NTSSCALE: NTS THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 48 NOT REFLECT ACTUAL SITE CONDITIONS. 30 30 NEITHER PARTY SHALL HAVE ANY OBLIGATION NOTE: X = 36" MIN, IF Y = 60" NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS 48 X 48 PULL SIDEPULL SIDE 30 FULLYEXECUTEDBYBOTHPARTIES 24 MIN PULL SIDE 29 MIN STARBUCKS TEMPLATE VERSION i2017.08.25 CLEAR FLOOR SPACE PARALLEL APPROACHFORWARD APPROACH CLEAR MIN Y Y 60 MIN 18 MIN, B.O. MIRROR X 60MIN 17 19 MAX T.O. LAVATORY 24 @ EXTERIOR DOOR 14 Design Forum MAX 30"X48" CLEAR 48 30"X48" CLEAR 44 MAX FLOOR SPACE FLOOR SPACE 29 MIN APRON CLEARANCE 17 Architects Inc. 9 MIN 27 MIN 40 MAX 34 MAX MAX 700 W. Pete Rose Way, Suite 460Donald J. Rethman FRONT APPROACH -LATCH SIDE APPROACH HINGE SIDE APPROACH - 8 MIN ADA SIGNS Cincinnati, OH 45203Architect In Charge 6 MAX TOE NOTES Tel: (513) 421-2210License: AR19700147 KNEE SWINGING DOOR CLEARANCE ELEVATIONSPLAN SWINGING DOOR SWINGING DOOR DO NOT EXTENDBEYOND RIM SIGNS TO BE A TYPICAL 6. CHARACTERS AND SYMBOLS 1. PLAN CLEARANCE 17 MIN, 19 MAX 6"ONE PIECE INJECTION SHALL CONTRAST WITH THEIR ELEVATIONS MIN. MOLDED FABRICATION BACKGROUND. Design Forum WITH RAISED SECOND IDENTIFICATION SYMBOLS ARE 2. SURFACE GRAPHICS. Engineering 5" TO BE ON WALL ADJACENT URINAL CLEARANCESLAVATORY CLEARANCES GRADE 2 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 7.SIGN TO BE A CUSTOM DOOR 60" ABOVE FLOOR AND Cincinnati, OH 45203Professional Engineer BRAILLE COLOR TO MATCH PMS License: PE10504904 ARE TO BE DISTINCTLY Tel: (513) 421-2210 NOTE: Y = 48" MIN,NOTE: X = 12" MIN,NOTE: Y = 48" MIN, 262C WITH WHITE DIFFERENT FROM DOOR AND IF DOOR HAS BOTH A IF DOOR HAS CLOSERIF DOOR HAS BOTH A SECTION 4.18 URINALSSEC. 4.19 LAVATORIES & MIRRORS GRAPHICS. CLOSER AND LATCHCLOSER AND LATCHWALL IN COLOR AND CONTRAST. 1410 SCALE: NTSSCALE: NTS 3.PROVIDE ROOM IDENTIFICATION BRAILLE SHOWN IS FOR 8. X 24 MIN X SIGN ON LATCH SIDE OF DOOR. PUSH SIDE PLACEMENT ONLY. USE MIN24 PUSH SIDE PUSH SIDE CORRECT BRAILLE FOR LETTERS & NUMBERS ON SIGNS 4. ADA ROOM 36 MIN 36 MIN6 MAX SIGN PRODUCTION. SHALL BE RAISED 1/32" MIN., Y Y IDENTIFICATION 36 MIN 6 MAX 48 MIN SHALL BE A MIN. OF 5/8" HIGH & 44 MIN 44 MIN 3D TACTILE PLAQUES 9. SIGN (1/4" THK.) 12 MIN12 MIN SHALL BE SANS-SERIF CAN BE OBTAINED FROM UPPERCASE CHARACTERS. AMERICRAFT 48" MIN. 33-36 60" MAX A.D.A. SIGNAGE ACCOMPANIED 11/01/1709/01/17 CORPORATION (SIGN BY GRADE 2 BRAILLE. LANGUAGE) 904 4TH 33-36 STREET WEST PALMETTO, REGULATORY SIGNS TO BE 5. BACK WALL OF STANDARD STALL FRONT APPROACH -SIDE APPROACH - LATCH SIDE APPROACH LATCH SIDE (B.O. LOWEST CHARACTERS) FL 34221 PH# (B.O. HIGHEST CHARACTERS)TYPICALLY ADA COMPLIANT L SWINGING DOORSWINGING DOOR SWINGING DOOR BACK WALL OF DOOR 1-800-237-3984 FAX TACTILE 3-D PLAQUES PER L 1-813-723-2452 CODE REQUIREMENTS. Y GRAB BARS AT WATER CLOSETS E W C D L 42 MIN 12 MAX 54" MIN K 36 MAX P C L L 12" MAX3' - 6" MIN L E 3 TOILET PAPER L 24 MIN 54 MIN 3 12 MAX Z 3' - 3" E 0 33 A D6 1' - 6" 4 17-19 19 MIN L H C L 48 MIN 24" MIN 60 MIN 44 MIN E 44 MIN N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt SIDE WALL OF STANDARD STALL Z 24 MIN& , 3' - 5" A 15 MIN L 2' - 9" T H E 60 MIN 17" - 19" * 48 12 LATCH SIDE APPROACH - S FRONT APPROACH -SLIDE SIDE APPROACH -0 30"6 M 7 SLIDING OR FOLDING DOORS SLIDING OR FOLDING DOORSSLIDING OR FOLDING DOORS 1 R 1 MANEUVERING 3 A GRAB BARS AT WATER CLOSETS MANEUVERING 3 WHEELCHAIR TURNING SPACE CLEARANCE FOR ALCOVE 1 1C CLEARANCE FOR ALCOVE 78" MIN STORE #:8123 32 MIN 48" MIN PROJECT #:25450-048 36 MIN3'-0" ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA COUNTERTOP 24 MAX R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 48 MIN 48 MIN 18 CHECKED BY: CABINET X A EMPLOYEE SIDECUSTOMER SIDE M Revision Schedule 60 MIN CLEAR 2 1 FLOOR RevDateByDescription SPACE 2'-10" SERVICE 3' - 1 ESPRESSO 6" 36 MIN 56 MIN W/ WALL MOUNTED W.C. 60 MIN48 MIN C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 59 MIN W/ FLR. MOUNTED W.C. TWO HINGED DOORS IN SERIESTWO HINGED DOORS IN SERIES MINIMUM CLEAR WIDTHMINIMUM CLEAR WIDTH MINIMUM CLEAR WIDTH FOR TWO WHEELCHAIRSFOR ONE WHEELCHAIRS STANDARD STALL (END OF ROW) FOR SINGLE WHEELCHAIR SHEET TITLE: ACCESSIBILITY SECTION 4.13 DOORSSECTION 4.17 TOILET STALLSTYP SECTION @ COUNTERSECTION 4.2 SPACE ALLOWANCES GUIDELINES 2416128 SCALE: NTSSCALE: NTSSCALE: NTSSCALE: NTS NO SCALE SCALE: SHEET NUMBER: G-0003 10/31/2017 6:16:58 PM SHEET NOTES 1.EXISTING BUILDING SHELL. 2.RELOCATE EXISTING ESPRESSO CASEWORK AS INDICATED ON CASEWORK PLAN. 3.INSTALL NEW CASEWORK ITEMS AS INDICATED ON CASEWORK PLAN. 4.INSTALL NEW CONDIMENT CART AS INDICATED ON CASEWORK PLAN. 5.INSTALL NEW PLUMBING ITEMS AS INDICATED ON FF&E PLAN & PLUMBING DRAWINGS. R 6.INSTALL NEW EQUIPMENT AS INDICATED ON FF&E PLAN. C 2017 STARBUCKS COFFEE COMPANY 7.RELOCATE EXISTING MISCELLANEOUS ITEMS AS INDICATED ON FF&E PLAN. STARBUCKS COFFEE 8.INSTALL NEW FURNITURE AS INDICATED ON FF&E PLAN. COMPANY 2401 UTAH AVENUE SOUTH 9.INSTALL NEW ELECTRICAL OUTLETS AS INDICATED ON PENETRATION PLAN AND ELECTRICAL DRAWINGS. SEATTLE, WASHINGTON 98134 (206) 318-1575 10.INSTALL NEW GRAPHICS AS INDICATED ON INTERIOR ELEVATIONS. THESE DRAWINGS AND SPECIFICATIONS ARE 11.CONSTRUCT NEW INTERIOR PARTITION WALLS AS INDICATED ON CONFIDENTIAL AND SHALL REMAIN THE SOLE FLOOR PLAN. PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN 12.INSTALL NEW WALL FINISHES THROUGHOUT AS INDICATED ON THIS WORK. THEY SHALL NOT BE INTERIOR ELEVATIONS AND WALL FINISH PLAN. REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER 13.INSTALL NEW FLOOR FINISHES AS INDICATED ON FLOOR FINISH PLAN. ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN 14.INSTALL NEW LIGHT FIXTURES AS INDICATED ON REFLECTED CEILING CONSENT OF STARBUCKS CORPORATION. AND DIMENSIONED LIGHTING PLAN. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A 15.INSTALL NEW CEILING FINISHES AS INDICATED ON REFLECTED CEILING PROTOTYPICAL STARBUCKS STORE (WHICH IS AND DIMENSIONED CEILING PLAN. SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. 16.PATCH, PRIME AND PAINT WALL, CEILING AND/OR SOFFIT AS NEITHER PARTY SHALL HAVE ANY OBLIGATION INDICATED ON REFLECTED CEILING PLAN AND INTERIOR ELEVATIONS. NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS 17.INSTALL NEW WALK-OFF MAT AS INDICATED ON FLOOR FINISH PLAN. FULLYEXECUTEDBYBOTHPARTIES 111 18.RELOCATE EXISTING EQUIPMENT AS INDICATED ON FF&E PLAN. STARBUCKS TEMPLATE VERSION i2017.08.25 19.EXISTING ELECTRICAL PANELS TO REMAIN. 20.NEW DRIVE-THRU WINDOW AND HAND-OFF SHELF BY GC. Design Forum 21.BIKE RACK BY GC. MEN'S Architects Inc. RESTROOM 22.EXISTING CANOPY ABOVE TO REMAIN. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 1 Cincinnati, OH 45203Architect In Charge 51112 Tel: (513) 421-2210License: AR19700147 23.EXISTING PATIO RAILING TO REMAIN. 131415 24.EXISTING STRUCTURAL COLUMN TO REMAIN. Design Forum NOTE:Engineering HALLWAY 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE REFER TO SHEETS A-1000 AND A-1001 FOR SITE SCOPE OF WORK. 19 Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 111213 141516 WOMEN'S ADAADA RESTROOM 378910 51112 1213141516 131415 11/01/1709/01/17 24 ADA L L Y E 5 W D K P L 17 L E 22 3 CAFE/SEATING L 3 2 Z 19 E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L 4 T H E 21 1 S 0 M BEVERAGE 7 WORKROOM 1 R 1 PREP. 3 ADA A 6111213 3 35691012 1 1C 14151618 1113141518 6 STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 8 DESIGNER: LISA MACEDA PATIO 23 R LEED AP: 8 PRODUCTION DESIGNER: PETER CHEETHAM 1ADA 11 CHECKED BY: Revision Schedule RevDateByDescription 1 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 23 SHEET TITLE: SCOPE OF WORK PLAN 1201 1/4" = 1'-0" SCALE: 02'4'8' SCOPE OF WORK PLAN SHEET NUMBER: 1 N Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" G-0004 10/31/2017 6:17:15 PM R C 2017 STARBUCKS COFFEE COMPANY STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN DESIGN ID # 12688DESIGN ID # 12689DESIGN ID # 12680DESIGN ID # 14298DESIGN ID # 14403 ABDDD THIS WORK. THEY SHALL NOT BE ABCDE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A GRAPHICS AND ARTWORK SCHEDULE - "G" PROTOTYPICAL STARBUCKS STORE (WHICH IS SHEET NOTES SUBJECT TO CHANGE AT ANYTIME) AND DO DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS NOT REFLECT ACTUAL SITE CONDITIONS. GRAPHICS - ARTWORK A.RECYCLING EDUCATION DISK. MOUNT ON NEITHER PARTY SHALL HAVE ANY OBLIGATION CONDIMENT CART AS REQUIRED. X1401117657; FRAMED WITH NO MAT; PAPER TYPE:SB-GCSEE ELEVATION 2/I-2101; BY GFX NOR LIABILITY TO THE OTHER (EXCEPT STATED PAPER 1; FRAME: LARSON-JUHL N11719 ABOVE) UNTIL A WRITTEN AGREEMENT IS FROSTED WALNUT 1/4" SPACER; OVERALL B.ENERGY EDUCATION DISK. REFER TO FULLYEXECUTEDBYBOTHPARTIES SIZE: 45" W X 45" H; METAL FRAME RESTROOM ELEVATIONS FOR PLACEMENT. THICKNESS: 1/4" STARBUCKS TEMPLATE VERSION i2017.08.25 C.MUGS EDUCATION DISK. MOUNT ON X1402117659; FRAMED WITH NO MAT; PAPER TYPE:SB-GCSEE ELEVATION 2/I-2101; BY GFX POS COUNTER AS REQUIRED. PAPER 1; FRAME: LARSON-JUHL N11719 FROSTED WALNUT 1/4" SPACER; OVERALL D.GROUNDS FOR YOUR GARDEN DISK. MOUNT SIZE: 45" W X 45" H; METAL FRAME Design Forum ON TOP OF CONDIMENT CART AS REQUIRED. THICKNESS: 1/4" X1403117681; PRINTED ON DREAMSCAPE CANVASSB-GCSEE ELEVATION: 3/I-2101; BY GFX E.WATER LOW FLOW EDUCATION DISK. REFER Architects Inc. AS WALLCOVERING; BACKGROUND: WHITE; F14403 E TO RESTROOM ELEVATIONS FOR MEN'S ART: BLACK; OVERALL SIZE: 45' -2" W X 9'- 3" 700 W. Pete Rose Way, Suite 460Donald J. Rethman PLACEMENT. Cincinnati, OH 45203Architect In Charge H RESTROOM 12689 F B Tel: (513) 421-2210License: AR19700147 X14041CUSTOM COMMUNITY BOARD; FRAMEDSB-GCSEE ELEVATION: 1/I-2101; BY GFX MAGNETIC COMMUNITY BOARD; FRAME: 413677, NATURAL MAPLE; Design Forum OVERALL SIZE: 3' - 0" W X 4' - 0" H GRAPHICS - INTERIOR MENU Engineering 128375MENU BOARD - 1 FRONT PANEL INSERTSB-GC STYLE 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer 128381MENU BOARD - DAILY OFFERINGSB-GC License: PE10504904 Tel: (513) 421-2210 HALLWAY CHALKBOARD FRONT PANEL RECTANGULAR 128396MENU BOARD - UNIVERSAL MOUNTINGSB-GC HARDWARE FOR FRONT PANELS GRAPHICS - OTHER 107532RESTROOM SIGN SET ACCESSIBLESB-GC 115261BULLETIN BOARD - 36X24IN 915X610MMSB-GC 126801EDUCATION DISK - MUGSSB-GCDUGGAL 126881EDUCATION DISK RECYCLESB-GCDUGGAL 126892EDUCATION DISK - HAND DRYERSB-GCDUGGAL WOMEN'S ADAADA 142981EDUCATION DISK - GROUNDS FOR YOURSB-GCDUGGAL RESTROOM GARDEN G12689 B 144032EDUCATION DISK - WATER LOW FLOWSB-GCDUGGAL 11/01/17 09/01/17 G14403 E L ADA L Y E RESPONSIBILITY LEGEND W D SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR K P L SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS L E 3 L GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY C 3 Z E GENERAL CONTRACTOR 0 CAFE/SEATING G12680 A D6 NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS 4 L 3"H DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION E N 3" I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 6" VIF Z & , 12688 G A 2' - 0" A L T H VIF E S 0 M 3" 7 1 R G14298 D 1 BEVERAGE 3 A WORKROOM 3 PREP. 1 1C ADA 3" STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PATIO PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: ADA Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: LEED EDUCATIONAL SIGNAGE PLAN 1/4" = 1'-0" SCALE: SHEET NUMBER: 02'4'8' LEED EDUCATIONAL SIGNAGE PLAN 1 N Scale: 1/4" = 1'-0" G-0005 Scale: 1/4" = 1'-0" 10/31/2017 6:17:29 PM R C 2017 STARBUCKS COFFEE COMPANY STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 Design Forum Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 Design Forum Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 NOTE: 3D VIEWS ARE FOR REFERENCE ONLY. REFER TO DETAIL SHEETS FOR CONSTRUCTION.NOTE: 3D VIEWS ARE FOR REFERENCE ONLY. REFER TO DETAIL SHEETS FOR CONSTRUCTION. VIEW TO FRONT BARVIEW TO CONDIMENT CART 12 11/01/17 09/01/17 L L Y E W D K P L L E 3 L 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: PERSPECTIVE VIEWS NO SCALE SCALE: 3D VIEWS ARE FOR REFERENCE ONLY. REFER TO DETAIL SHEETS FOR CONSTRUCTION. 3D VIEWS ARE FOR REFERENCE ONLY. REFER TO DETAIL SHEETS FOR CONSTRUCTION. NOTE:NOTE: VIEW TOWARDS HALLWAY VIEW TO CAFE SEATING SHEET NUMBER: 3 G-0006 10/31/2017 6:18:12 PM GENERAL CONDITIONSGENERAL CONDITIONS (CONTINUED)GENERAL CONDITIONS (CONTINUED)GENERAL CONDITIONS (CONTINUED) SECTION 018100 - SUSTAINABLE DESIGN REQUIREMENTS SECTION 014200 - REFERENCESSECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSALSECTION 019113 - GENERAL COMMISSIONING REQUIREMENTS 1.1SUMMARY PART 1 - GENERAL1.1SUMMARY1.1SUMMARY A.THIS SECTION INCLUDES GENERAL REQUIREMENTS AND PROCEDURES 1.1INDUSTRY STANDARDSA.SALVAGING NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE.A.COMMISSIONING TEAM: FOR COMPLIANCE WITH CERTAIN U.S. GREEN BUILDING COUNCIL'S A.APPLICABILITY OF STANDARDS: UNLESS THE CONTRACT DOCUMENTSB.RECYCLING NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE.1.MEMBERS REPRESENTING CONTRACTOR, INCLUDING PROJECT (USGBC) LEED PREREQUISITES AND CREDITS NEEDED FOR THE PROJECT SUPERINTENDENT AND SUBCONTRACTORS, INSTALLERS, SUPPLIERS, INCLUDE MORE STRINGENT REQUIREMENTS, APPLICABLE CONSTRUCTIONC.DISPOSING OF NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE. TO OBTAIN LEED CERTIFICATION BASED ON \[LEED 2009 FOR RETAIL: INDUSTRY STANDARDS HAVE THE SAME FORCE AND EFFECT AS IF BOUND1.2DEFINITIONSAND SPECIALISTS. COMMERCIAL INTERIORS\] \[LEED 2009 FOR RETAIL: NEW CONSTRUCTION\]. OR COPIED DIRECTLY INTO THE CONTRACT DOCUMENTS TO THE EXTENTA.CONSTRUCTION WASTE: BUILDING AND SITE IMPROVEMENT MATERIALS2.MEMBERS REPRESENTING OWNER, INCLUDING COMMISSIONING 1.OTHER LEED PREREQUISITES AND CREDITS NEEDED TO OBTAIN LEED AGENT (CXA), FACILITY USER AND OPERATION AND MAINTENANCE REFERENCED. SUCH STANDARDS ARE MADE A PART OF THE CONTRACTAND OTHER SOLID WASTE RESULTING FROM CONSTRUCTION, REMODELING, CERTIFICATION ARE DEPENDENT ON MATERIAL SELECTIONS DOCUMENTS BY REFERENCE.RENOVATION, OR REPAIR OPERATIONS. CONSTRUCTION WASTE INCLUDESPERSONNEL, AND ARCHITECT AND ENGINEERING DESIGN R AND MAY NOT BE SPECIFICALLY IDENTIFIED AS LEED B.PUBLICATION DATES: COMPLY WITH STANDARDS IN EFFECT AS OF DATE OFPACKAGING.PROFESSIONALS. REQUIREMENTS. COMPLIANCE WITH REQUIREMENTS NEEDED TO THE CONTRACT DOCUMENTS UNLESS OTHERWISE INDICATED.B.DEMOLITION WASTE: BUILDING AND SITE IMPROVEMENT MATERIALSB.CONTRACTOR'S RESPONSIBILITIES: CONTRACTOR SHALL ASSIGN C 2017 STARBUCKS COFFEE COMPANY OBTAIN LEED PREREQUISITES AND CREDITS MAY BE USED AS ONE REPRESENTATIVES WITH EXPERTISE AND AUTHORITY TO ACT ON ITS C.COPIES OF STANDARDS: EACH ENTITY ENGAGED IN CONSTRUCTION ONRESULTING FROM DEMOLITION OR SELECTIVE DEMOLITION OPERATIONS. CRITERION TO EVALUATE SUBSTITUTION REQUESTS. PROJECT SHOULD BE FAMILIAR WITH INDUSTRY STANDARDS APPLICABLE TOC.DISPOSAL: REMOVAL OFF-SITE OF DEMOLITION AND CONSTRUCTIONBEHALF AND SHALL SCHEDULE THEM TO PARTICIPATE IN AND PERFORM 2.ADDITIONAL LEED PREREQUISITES AND CREDITS NEEDED TO ITS CONSTRUCTION ACTIVITY. COPIES OF APPLICABLE STANDARDS ARE NOTWASTE AND SUBSEQUENT SALE, RECYCLING, REUSE, OR DEPOSIT INCOMMISSIONING PROCESS ACTIVITIES INCLUDING, BUT NOT LIMITED TO, STARBUCKS COFFEE OBTAIN THE INDICATED LEED CERTIFICATION ARE DEPENDENT ON THE FOLLOWING: BOUND WITH THE CONTRACT DOCUMENTS.LANDFILL OR INCINERATOR ACCEPTABLE TO AUTHORITIES HAVING THE ARCHITECT'S DESIGN AND OTHER ASPECTS OF THE PROJECT 1.WHERE COPIES OF STANDARDS ARE NEEDED TO PERFORM AJURISDICTION.1.INTEGRATE AND COORDINATE COMMISSIONING PROCESS ACTIVITIES COMPANY THAT ARE NOT PART OF THE WORK OF THE CONTRACT. REQUIRED CONSTRUCTION ACTIVITY, OBTAIN COPIES DIRECTLYD.RECYCLE: RECOVERY OF DEMOLITION OR CONSTRUCTION WASTE FORWITH CONSTRUCTION SCHEDULE. 1.2DEFINITIONS FROM PUBLICATION SOURCE.SUBSEQUENT PROCESSING IN PREPARATION FOR REUSE.2.REVIEW AND ACCEPT COMMISSIONING CHECKLISTS AND PROCESS 2401 UTAH AVENUE SOUTH A.BASE BUILDING MATERIAL: MATERIALS PERMANENTLY ATTACHED TO THE 1.2ABBREVIATIONS AND ACRONYMSE.SALVAGE: RECOVERY OF DEMOLITION OR CONSTRUCTION WASTE ANDTEST PROCEDURES PROVIDED BY THE COMMISSIONING AGENT (CXA). SEATTLE, WASHINGTON 98134 STRUCTURE. INCLUDES FINISHES AND PERMANENT CABINETS AND A.INDUSTRY ORGANIZATIONS: WHERE ABBREVIATIONS AND ACRONYMS ARESUBSEQUENT SALE OR REUSE IN ANOTHER FACILITY.3.SUPPORT COMMISSIONING INSTALLATION REVIEW AND PROCESS (206) 318-1575 CASEWORK. USED IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THEY SHALLF.SALVAGE AND REUSE: RECOVERY OF DEMOLITION OR CONSTRUCTIONTEST PROCEDURES. B.CHAIN-OF-CUSTODY CERTIFICATES: CERTIFICATES SIGNED BY 4.EVALUATE INSTALLATION AND PERFORMANCE DEFICIENCIES MEAN THE RECOGNIZED NAME OF THE ENTITIES IN THE FOLLOWING LIST.WASTE AND SUBSEQUENT INCORPORATION INTO THE WORK. THESE DRAWINGS AND SPECIFICATIONS ARE MANUFACTURERS CERTIFYING THAT WOOD USED TO MAKE PRODUCTS 1.3PERFORMANCE REQUIREMENTSIDENTIFIED IN REPORTS AND, IN COLLABORATION WITH ENTITY CONFIDENTIAL AND SHALL REMAIN THE SOLE WAS OBTAINED FROM FORESTS CERTIFIED BY AN FSC-ACCREDITED ACIAMERICAN CONCRETE INSTITUTE RESPONSIBLE FOR SYSTEM AND EQUIPMENT INSTALLATION, A.END-OF-PROJECT RATES FOR SALVAGE/RECYCLING: \[50\] \[75\] PERCENT. PROPERTY OF STARBUCKS CORPORATION, CERTIFICATION BODY TO COMPLY WITH FSCSTD-01-001, "FSC PRINCIPLES RECOMMEND CORRECTIVE ACTION. AHAAMERICAN HARDBOARD ASSOCIATION 1.4ACTION SUBMITTALS WHICH IS THE OWNER OF THE COPYRIGHT IN AND CRITERIA FOR FOREST STEWARDSHIP." CERTIFICATES SHALL AITCAMERICAN INSTITUTE OF TIMBER CONSTRUCTION 5.COOPERATE WITH THE COMMISSIONING TEAM FOR RESOLUTION OF A.WASTE MANAGEMENT PLAN: SUBMIT PLAN WITHIN 7 DAYS OF DATE THIS WORK. THEY SHALL NOT BE INCLUDE EVIDENCE THAT MANUFACTURER IS CERTIFIED FOR CHAIN OF ANSIAMERICAN NATIONAL STANDARDS INSTITUTE ISSUES RECORDED IN THE ISSUES LOG. ESTABLISHED FOR COMMENCEMENT OF THE WORK. REPRODUCED (IN WHOLE OR IN PART), SHARED CUSTODY BY AN FSC-ACCREDITED CERTIFICATION BODY. APAAPA - THE ENGINEERED WOOD ASSOCIATION C.COMMISSIONING AGENTÓS (CXA'S) RESPONSIBILITIES: 1.TYPES AND QUANTITIES OF DEMOLITION AND CONSTRUCTION WITH THIRD PARTIES OR USED IN ANY MANNER C.REGIONALLY MANUFACTURED MATERIALS: MATERIALS THAT ARE ASHRAEAMERICAN SOCIETY OF HEATING, REFRIGERATING AND1.ORGANIZE AND LEAD COMMISSIONING TEAM. WASTE. ON OTHER PROJECTS OR EXTENSIONS TO THIS MANUFACTURED WITHIN A RADIUS OF 500 MILES (800 KM) FROM PROJECT AIR-CONDITIONING ENGINEERS 2.PROVIDE AND MANAGE COMMISSIONING PLAN. 2.TYPE OF WASTE AND WHETHER IT WILL BE SALVAGED, RECYCLED, PROJECT WITHOUT THE PRIOR WRITTEN SITE. MANUFACTURING REFERS TO THE FINAL ASSEMBLY OF ASTMASTM INTERNATIONAL 3.PROVIDE PROJECT-SPECIFIC CHECKLISTS AND TEST PROCEDURES. OR DISPOSED OF IN LANDFILL OR INCINERATOR. CONSENT OF STARBUCKS CORPORATION. COMPONENTS INTO THE BUILDING PRODUCT THAT IS INSTALLED AT 4.WITNESS, PREPARE AND MAINTAIN COMPLETED INSTALLATION (AMERICAN SOCIETY FOR TESTING AND MATERIALS INTERNATIONAL) 3.NET ADDITIONAL COST OR NET SAVINGS RESULTING FROM WASTE THESE DRAWINGS AND SPECIFICATIONS ARE PROJECT SITE. AWIARCHITECTURAL WOODWORK INSTITUTE VERIFICATION CHECKLISTS. MANAGEMENT PLAN. INTENDED TO EXPRESS DESIGN INTENT FOR A D.REGIONALLY EXTRACTED AND MANUFACTURED MATERIALS: REGIONALLY AWPAAMERICAN WOOD PROTECTION ASSOCIATION 5.WITNESS SYSTEMS, ASSEMBLIES, EQUIPMENT, AND COMPONENT 1.5INFORMATION SUBMITTALS PROTOTYPICAL STARBUCKS STORE (WHICH IS MANUFACTURED MATERIALS MADE FROM RAW MATERIALS THAT ARE STARTUP. (FORMERLY: AMERICAN WOOD PRESERVERS' ASSOCIATION) A.WASTE REDUCTION PROGRESS REPORTS: CONCURRENT WITH EACH SUBJECT TO CHANGE AT ANYTIME) AND DO EXTRACTED, HARVESTED, OR RECOVERED WITHIN A RADIUS OF 500 MILES CRICARPET AND RUG INSTITUTE (THE) 6.WITNESS, PREPARE, AND MAINTAIN COMPLETED FUNCTIONAL APPLICATION FOR PAYMENT, SUBMIT REPORT INDICATING TYPE OF WASTE NOT REFLECT ACTUAL SITE CONDITIONS. (800 KM) FROMPROJECT SITE. CRRCCOOL ROOF RATING COUNCIL TESTING CHECKLISTS. AND WHETHER IT HAS BEEN SALVAGED, RECYCLED, OR DISPOSED OF IN NEITHER PARTY SHALL HAVE ANY OBLIGATION E.RECYCLED CONTENT: MATERIAL THAT HAS BEEN BROKEN DOWN AND CSACANADIAN STANDARDS ASSOCIATION 7.PREPARE AND MAINTAIN THE ISSUES LOG. LANDFILL OR INCINERATOR. NOR LIABILITY TO THE OTHER (EXCEPT STATED RECONSTITUTED INTO NEW MATERIAL. THE RECYCLED CONTENT VALUE CSACSA INTERNATIONAL 8.COMPILE COMMISSIONING DOCUMENTS, RESULTS, AND B.WASTE DISPOSAL RECORDS: INDICATE RECEIPT AND ACCEPTANCE OF ABOVE) UNTIL A WRITTEN AGREEMENT IS OF A MATERIAL ASSEMBLY SHALL BE DETERMINED BY WEIGHT. THE (FORMERLY: IAS - INTERNATIONAL APPROVAL SERVICES) DEFICIENCIES; INCLUDE THEM IN THE SYSTEMS MANUAL AND WASTE MATERIAL BY ACCEPTING AND PROCESSING FACILITIES LICENSED FULLYEXECUTEDBYBOTHPARTIES RECYCLED FRACTION OF THE ASSEMBLY IS THEN MULTIPLIED BY THE CSICONSTRUCTION SPECIFICATIONS INSTITUTE (THE) COMMISSIONING SUMMARY REPORT. TO ACCEPT THEM. INCLUDE MANIFESTS, TYPE OF MATERIAL, WEIGHT OR COST OF ASSEMBLY TO DETERMINE THE RECYCLED CONTENT VALUE. 9.REVIEW COMMISSIONING REPORT WITH COMMISSIONING TEAM AND ETL SEMCOINTERTEK ETL SEMCO VOLUME TICKETS, RECEIPTS, AND INVOICES. 1."POST-CONSUMER" MATERIAL IS DEFINED AS WASTE MATERIAL STARBUCKS TEMPLATE VERSION i2017.08.25 (FORMERLY: ITS - INTERTEK TESTING SERVICE NA) IMPLEMENT PLAN TO RESOLVE DEFICIENCIES. C.LEED SUBMITTAL: CWM REPORTING TEMPLATE, TABULATING TOTAL GENERATED BY HOUSEHOLDS OR BY COMMERCIAL, INDUSTRIAL, FM GLOBALFM GLOBAL END OF SECTION 019113 WASTE MATERIAL, QUANTITIES DIVERTED AND MEANS BY WHICH IT IS AND INSTITUTIONAL FACILITIES IN THEIR ROLE AS END USERS OF (FORMERLY: FMG - FM GLOBAL) DIVERTED, AND STATEMENT THAT REQUIREMENTS FOR THE CREDIT HAVE THE PRODUCT, WHICH CAN NO LONGER BE USED FOR ITS FSCFOREST STEWARDSHIP COUNCIL BEEN MET. Design Forum INTENDED PURPOSE. HPVAHARDWOOD PLYWOOD & VENEER ASSOCIATION 1.6RECYCLING WASTE 2."PRE-CONSUMER" MATERIAL IS DEFINED AS MATERIAL DIVERTED ISOINTERNATIONAL ORGANIZATION FOR STANDARDIZATION A.RECYCLING INCENTIVES: REVENUES AND OTHER INCENTIVES FOR FROM THE WASTE STREAM DURING THE MANUFACTURING ITSINTERTEK TESTING SERVICE NA RECYCLING WILL ACCRUE TO OWNER. Architects Inc. PROCESS. EXCLUDED IS REUTILIZATION OF MATERIALS SUCH AS (NOW ETL SEMCO) END OF SECTION 017419 700 W. Pete Rose Way, Suite 460Donald J. Rethman REWORK, REGRIND, OR SCRAP GENERATED IN A PROCESS AND MFMAMAPLE FLOORING MANUFACTURERS ASSOCIATION, INC. Cincinnati, OH 45203Architect In Charge CAPABLE OF BEING RECLAIMED WITHIN THE SAME PROCESS THAT MPIMASTER PAINTERS INSTITUTE Tel: (513) 421-2210License: AR19700147 GENERATED IT. NFPANFPA F.RESOURCE REUSE: MATERIAL THAT HAS BEEN KEPT INTACT AND (NATIONAL FIRE PROTECTION ASSOCIATION) REPURPOSED TO A NEW USE ON THE SAME PROJECT SITE OR FOR THE NOFMANOFMA: THE WOOD FLOORING MANUFACTURERS ASSOCIATION Design Forum ORIGINAL OR NEW USE ON A DIFFERENT PROJECT SITE. FURNITURE MAY (FORMERLY: NATIONAL OAK FLOORING MANUFACTURERS BE REPURPOSED FOR THE ORIGINAL USE ON THE SAME PROJECT SITE. ASSOCIATION) 1.3SUBMITTALS OPLINTERTAK Engineering A.GENERAL: SUBMIT ADDITIONAL LEED SUBMITTALS REQUIRED BY OTHER SDISTEEL DOOR INSTITUTE 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE SPECIFICATION SECTIONS. SMACNASHEET METAL AND AIR CONDITIONING CONTRACTORS' Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 B.LEED DOCUMENTATION SUBMITTALS: NATIONAL ASSOCIATION 1.CREDITMR2: COMPLY WITH SECTION017419 "CONSTRUCTION ULUNDERWRITERS LABORATORIES INC. WASTE MANAGEMENT AND DISPOSAL." USGBCU.S. GREEN BUILDING COUNCIL 2.CREDITMR3: RECEIPTS FOR SALVAGED AND REFURBISHED MATERIALS WCLIBWEST COAST LUMBER INSPECTION BUREAU USED FOR PROJECT, INDICATING SOURCES AND COSTS FOR SALVAGED WIWOODWORK INSTITUTE (FORMERLY: WIC - WOODWORK INSTITUTE AND REFURBISHED MATERIALS. OF CALIFORNIA) 3.CREDITMR4: PRODUCT DATA AND CERTIFICATION LETTER FROM PRODUCT B.CODE AGENCIES: WHERE ABBREVIATIONS AND ACRONYMS ARE USED IN MANUFACTURERS INDICATING PERCENTAGES BY WEIGHT OF POST-CONSUMER SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THEY SHALL MEAN AND PRE-CONSUMER RECYCLED CONTENT FOR PRODUCTS HAVING RECYCLED THE RECOGNIZED NAME OF THE ENTITIES IN THE FOLLOWING LIST. CONTENT. INCLUDE STATEMENT INDICATING MATERIAL COSTS FOR EACH PRODUCT DINDEUTSCHES INSTITUT FUR NORMUNG E.V. HAVING RECYCLED CONTENT. ICCINTERNATIONAL CODE COUNCIL 4.CREDITMR5: PRODUCT DATA INDICATING LOCATION OF MATERIAL MANUFACTURER ICC-ESICC EVALUATION SERVICE, INC. FOR REGIONALLY MANUFACTURED MATERIALS. INCLUDE STATEMENT INDICATING C.FEDERAL GOVERNMENT AGENCIES: WHERE ABBREVIATIONS AND COST FOR EACH REGIONALLY MANUFACTURED MATERIALAND FOR EACH IONALLY CRONYMS ARE USED IN SPECIFICATIONS OR OTHER CONTRACT 11/01/17 09/01/17 EXTRACTED AND MANUFACTURED MATERIAL. DOCUMENTS, THEY SHALL MEAN THE RECOGNIZED NAME OF THE a.INCLUDE STATEMENT INDICATING DISTANCE FROM MANUFACTURER TO ENTITIES IN THE FOLLOWING LIST. PROJECT FOR EACH REGIONALLY MANUFACTURED MATERIAL. EPAENVIRONMENTAL PROTECTION AGENCY b.INCLUDE STATEMENT INDICATING LOCATION OF AND DISTANCE FROM D.STANDARDS AND REGULATIONS: WHERE ABBREVIATIONS AND ACRONYMS PROJECT TO POINT OF EXTRACTION, HARVEST, OR RECOVERY FOR EACH ARE USED IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THEY L RAW MATERIAL USED IN REGIONALLY EXTRACTED AND MANUFACTURED SHALL MEAN THE RECOGNIZED NAME OF THE STANDARDS AND REGULATIONS L MATERIALS. IN THE FOLLOWING LIST. Y E 5.CREDITMR7: PRODUCT DATA AND CHAIN-OF-CUSTODY CERTIFICATES ADAAGAMERICANS WITH DISABILITIES ACT (ADA) W FOR PRODUCTS CONTAINING CERTIFIED WOOD. INCLUDE STATEMENT ARCHITECTURAL BARRIERS ACT (ABA) D INDICATING COST FOR EACH CERTIFIED WOOD PRODUCT. ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES K 6.CREDIT IEQ3.1: AVAILABLE FROM U.S. ACCESS BOARD P L a.CONSTRUCTION INDOOR-AIR-QUALITY MANAGEMENT PLAN. CFRCODE OF FEDERAL REGULATIONS L b.PRODUCT DATA FOR TEMPORARY FILTRATION MEDIA. E AVAILABLE FROM GOVERNMENT PRINTING OFFICE 3 L c.PRODUCT DATA FOR FILTRATION MEDIA USED DURING E.STATE GOVERNMENT AGENCIES: WHERE ABBREVIATIONS AND ACRONYMS 3 Z E OCCUPANCY. ARE USED IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THEY 0 A d.CONSTRUCTION DOCUMENTATION: SIX PHOTOGRAPHS AT D6 SHALL MEAN THE RECOGNIZED NAME OF THE ENTITIES IN THE FOLLOWING 4 THREE DIFFERENT TIMES DURING THE CONSTRUCTION LIST. L H PERIOD, ALONG WITH A BRIEF DESCRIPTION OF THE CDHSCALIFORNIA DEPARTMENT OF HEALTH SERVICES E N SMACNA APPROACH EMPLOYED, DOCUMENTING CDPHCALIFORNIA DEPARTMENT OF PUBLIC HEALTH, INDOOR AIR QUALITY I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & IMPLEMENTATION OF THE INDOOR-AIR-QUALITY SECTION , A MANAGEMENT MEASURES, SUCH AS PROTECTION OF L END OF SECTION 014200 T DUCTS AND ON-SITE STORED OR INSTALLED ABSORPTIVE H E MATERIALS. S 0 M 7.CREDIT IEQ3.2: 7 1 R a.SIGNED STATEMENT DESCRIBING THE BUILDING AIR FLUSH- 1 3 A OUT PROCEDURES INCLUDING THE DATES WHEN FLUSH- 3 OUT WAS BEGUN AND COMPLETED AND STATEMENT THAT 1 1C FILTRATION MEDIA WAS REPLACED AFTER FLUSH-OUT. b.PRODUCT DATA FOR FILTRATION MEDIA USED DURING STORE #:8123 FLUSH-OUT AND DURING OCCUPANCY. 8.CREDIT IEQ4A: PRODUCT DATA FOR ADHESIVES AND SEALANTS PROJECT #:25450-048 USED INSIDE THE WEATHERPROOFING SYSTEM INDICATING VOC ISSUE DATE: 11/1/17 CONTENT OF EACH PRODUCT USED. DESIGNER: LISA MACEDA 9.CREDIT IEQ4B: PRODUCT DATA FOR PAINTS AND COATINGS USED R LEED AP: INSIDE THE WEATHERPROOFING SYSTEM INDICATING VOC CONTENT PRODUCTION DESIGNER: PETER CHEETHAM OF EACH PRODUCT USED. CHECKED BY: 10.CREDIT IEQ4D: PRODUCT DATA FOR PRODUCTS CONTAINING COMPOSITE WOOD OR AGRIFIBER PRODUCTS OR WOOD GLUES INDICATING THAT THEY DO NOT CONTAIN UREA-FORMALDEHYDE Revision Schedule RESIN. 1.4INFORMATIONAL SUBMITTALS RevDateByDescription A.LEED ACTION PLANS: PROVIDE PRELIMINARY SUBMITTALS WITHIN SEVEN DAYS OF DATE ESTABLISHED FOR COMMENCEMENT OF THE WORK INDICATING HOW THE FOLLOWING REQUIREMENTS WILL BE MET: C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 1.CREDITMR2: WASTE MANAGEMENT PLAN COMPLYING WITH SECTION 017419 "CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL." 2.CREDIT IEQ3.1: CONSTRUCTION INDOOR-AIR-QUALITY MANAGEMENT PLAN. SHEET TITLE: B.LEED PROGRESS REPORTS: CONCURRENT WITH EACH APPLICATION FOR PAYMENT, SUBMIT REPORTS COMPARING ACTUAL CONSTRUCTION AND CONSTRUCTION PURCHASING ACTIVITIES WITH LEED ACTION PLANS FOR THE FOLLOWING: 1.CREDITMR2: WASTE REDUCTION PROGRESS REPORTS COMPLYING SPECIFICATIONS WITH SECTION017419 "CONSTRUCTION WASTE MANAGEMENT AND NO SCALE SCALE: DISPOSAL." END OF SECTION 018100 SHEET NUMBER: G-0010 10/31/2017 6:18:16 PM CONCRETECONCRETE (CONTINUED)WOOD AND PLASTICSWOOD AND PLASTICS (CONTINUED) SECTION 033000 - CAST-IN-PLACE CONCRETESECTION 033500 - CONCRETE FINISHINGSECTION 061053 - MISCELLANEOUS ROUGH CARPENTRYSECTION 064400 - PLASTIC PANELING 1.1SUMMARY1.1SUBMITTALS1.1MATERIALS PART 1 - GENERAL A.CAST-IN-PLACE CONCRETE, INCLUDING FORMWORK, REINFORCEMENT,A.QUALIFICATION DATA: FOR QUALIFIED APPLICATOR.A.WOOD PRODUCTS, GENERAL:1.1SUMMARY CONCRETE MATERIALS, MIXTURE DESIGN, PLACEMENT PROCEDURES,B.MATERIAL CERTIFICATES.1.MAXIMUM MOISTURE CONTENT OF LUMBER:A.SECTION INCLUDES THE FOLLOWING: AND FINISHES, FOR THE FOLLOWING:1.2FLOOR AND SLAB TREATMENTS1.GLASS-FIBER REINFORCED PLASTIC (FRP) WALL PANELING. 19 PERCENT. 1.FOOTINGS.A.VOC CONTENT: FLOOR TREATMENTS SHALL HAVE A VOC CONTENT OF 200G/L2.MOLDING, ADHESIVES, AND JOINT SEALANTS. B.WOOD-PRESERVATIVE-TREATED MATERIALS: 2.FOUNDATION WALLS.OR LESS WHEN CALCULATED ACCORDING TO 40CFR59, SUBPARTD (EPA1.2PLASTIC SHEET PANELING 1.PRESERVATIVE TREATMENT: AWPAU1; USE CATEGORYUC2. 3.SLABS-ON-GRADE.METHOD24).A.GLASS-FIBER-REINFORCED PLASTIC PANELING: GELCOAT-FINISHED, a.PRESERVATIVE CHEMICALS: CONTAINING NO ARSENIC OR R 1.2SUBMITTALSB.UNPIGMENTED MINERAL DRY-SHAKE FLOOR HARDENER: FACTORY-PACKAGEDGLASS-FIBER REINFORCED PLASTIC PANELS COMPLYING WITH ASTMD5319. CHROMIUM. DO NOT USE INORGANIC BORON (SBX) FOR SILL A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.DRY COMBINATION OF PORTLAND CEMENT, GRADED QUARTZ AGGREGATE,1.LOW-EMITTING MATERIALS: PANELING SHALL COMPLY WITH THE PLATES. B.SHOP DRAWINGS:AND PLASTICIZING ADMIXTURE.TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA C 2017 STARBUCKS COFFEE COMPANY 2.APPLICATION: ITEMS INDICATED AND THE FOLLOWING: 1.REINFORCING: PLACING DRAWINGS THAT DETAIL FABRICATION,C.PIGMENTED MINERAL DRY-SHAKE FLOOR HARDENER: FACTORY-PACKAGED,DEPARTMENT OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE a.ITEMS IN CONTACT WITH ROOFING OR WATERPROOFING. BENDING, AND PLACEMENT. INCLUDE BAR SIZES, LENGTHS,DRY COMBINATION OF PORTLAND CEMENT, GRADED QUARTZ AGGREGATE,TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS b.ITEMS IN CONTACT WITH CONCRETE OR MASONRY. STARBUCKS COFFEE MATERIAL, GRADE, BAR SCHEDULES, STIRRUP SPACING, BENTCOLOR PIGMENTS, AND PLASTICIZING ADMIXTURE. USE COLOR PIGMENTSSOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS." c.FRAMING LESS THAN 18 INCHES (460 MM) ABOVE GROUND IN BAR DIAGRAMS, BAR ARRANGEMENT, SPLICES AND LAPS,THAT ARE FINELY GROUND, NONFADING MINERAL OXIDES INTERGROUND WITH2.NOMINAL THICKNESS: NOT LESS THAN 0.09 INCHES. CRAWLSPACES. COMPANY MECHANICAL CONNECTIONS, TIE SPACING, HOOP SPACING, ANDCEMENT.3.COLOR: WHITE. d.FLOOR PLATES INSTALLED OVER CONCRETE SLABS-ON-GRADE. SUPPORTS FOR CONCRETE REINFORCEMENT. 1.3LIQUID FLOOR TREATMENTS4.MOLDING COLOR: WHITE. C.FIRE-RETARDANT-TREATED MATERIALS: 2401 UTAH AVENUE SOUTH 2.SLAB LAYOUTS: DIMENSION LOCATIONS OF CONTROL,A.VOC CONTENT: LIQUID FLOOR TREATMENTS SHALL HAVE A VOC CONTENT OF5.SURFACE FINISH: MOLDED PEBBLE TEXTURE. 1.EXTERIOR TYPE FOR EXTERIOR LOCATIONS AND WHERE INDICATED. SEATTLE, WASHINGTON 98134 EXPANSION, AND CONSTRUCTION JOINTS. RELATE TO BUILDING200G/L OR LESS WHEN CALCULATED ACCORDING TO 40CFR59, SUBPARTDB.UNREINFORCED POLYPROPYLENE PANELING: SOLID POLYPROPYLENE 2.INTERIOR TYPEA UNLESS OTHERWISE INDICATED. (206) 318-1575 GRID LINES.(EPA METHOD24).PANELS MADE FROM NO LESS THAN 80 PERCENT RECYCLED MATERIAL. 3.APPLICATION: ITEMS INDICATED AND THE FOLLOWING: C.DESIGN MIXTURES: FOR EACH CONCRETE MIXTURE. SUBMIT ALTERNATE B.PENETRATING LIQUID FLOOR TREATMENT: CLEAR, CHEMICALLY REACTIVE,1.LOW-EMITTING MATERIALS: PANELING SHALL COMPLY WITH THE a.FRAMING FOR RAISED PLATFORMS. THESE DRAWINGS AND SPECIFICATIONS ARE DESIGN MIXTURES WHEN CHARACTERISTICS OF MATERIALS, PROJECTWATERBORNE SOLUTION OF INORGANIC SILICATE OR SILICONATE MATERIALSTESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA b.CONCEALED BLOCKING. CONFIDENTIAL AND SHALL REMAIN THE SOLE CONDITIONS, WEATHER, TEST RESULTS, OR OTHER CIRCUMSTANCESAND PROPRIETARY COMPONENTS; ODORLESS; THAT PENETRATES, HARDENS,DEPARTMENT OF PUBLIC HEALTH'S (FORMERLY, THE CALIFORNIA c.ROOF FRAMING AND BLOCKING. PROPERTY OF STARBUCKS CORPORATION, WARRANT ADJUSTMENTS.AND DENSIFIES CONCRETE SURFACES.DEPARTMENT OF HEALTH SERVICES') "STANDARD METHOD FOR THE d.ITEMS IN CONTACT WITH ROOFING. WHICH IS THE OWNER OF THE COPYRIGHT IN 1.INDICATE AMOUNTS OF MIXING WATER TO BE WITHHELD FORC.PENETRATING LIQUID FLOOR TREATMENTS FOR POLISHED CONCRETE FINISH:TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL e.PLYWOOD BACKING PANELS. THIS WORK. THEY SHALL NOT BE LATER ADDITION AT PROJECT SITE.CLEAR, WATERBORNE SOLUTION OF INORGANIC SILICATE OR SILICONATEEMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL D.FRAMING: REPRODUCED (IN WHOLE OR IN PART), SHARED D.CERTIFICATIONS: SUBMIT MILL CERTIFICATES FOR CEMENT,MATERIALS AND PROPRIETARY COMPONENTS; ODORLESS; THAT PENETRATES,CHAMBERS." 1.NON-LOAD-BEARING INTERIOR PARTITIONS: CONSTRUCTION OR NO.2 WITH THIRD PARTIES OR USED IN ANY MANNER AGGREGATES, AND REINFORCING.HARDENS, AND IS SUITABLE FOR POLISHED CONCRETE SURFACES.2.NOMINAL THICKNESS: NOT LESS THAN 0.09 INCHES. GRADE. ON OTHER PROJECTS OR EXTENSIONS TO THIS 1.3MATERIALS1.4INSTALLATION3.COLOR: WHITE. E.MISCELLANEOUS LUMBER: PROJECT WITHOUT THE PRIOR WRITTEN A.STEEL REINFORCEMENT:A.DRY-SHAKE FLOOR HARDENER FINISH: AFTER INITIAL FLOATING, APPLY DRY-4.MOLDING COLOR: WHITE. 1.DIMENSION LUMBER: CONSTRUCTION OR NO.2 GRADE. CONSENT OF STARBUCKS CORPORATION. 1.REINFORCING BARS: DEFORMED.SHAKE FLOOR HARDENER TO SURFACES5.SURFACE FINISH: MOLDED PEBBLE TEXTURE. 2.UTILITY SHELVING: 19 PERCENT MAXIMUM MOISTURE CONTENT. THESE DRAWINGS AND SPECIFICATIONS ARE a.MINIMUM RECYCLED CONTENT: 60%B.PENETRATING LIQUID FLOOR TREATMENT: PREPARE, APPLY, AND FINISH1.3ADHESIVES 3.CONCEALED BOARDS: 19 PERCENT MAXIMUM MOISTURE CONTENT. INTENDED TO EXPRESS DESIGN INTENT FOR A 2.PLAIN-STEEL WELDED WIRE REINFORCEMENT: ASTMA185,PENETRATING LIQUID FLOOR TREATMENT ACCORDING TO MANUFACTURER'SA.AS RECOMMENDED BY PLASTIC PANELING MANUFACTURER. F.PLYWOOD BACKING PANELS: EXPOSURE1, C-D PLUGGED FIRE-RETARDANT PROTOTYPICAL STARBUCKS STORE (WHICH IS PLAIN, FABRICATED FROM AS-DRAWN STEEL WIRE INTO FLATWRITTEN INSTRUCTIONS.1.VOC LIMIT: 50 G/L TREATED. SUBJECT TO CHANGE AT ANYTIME) AND DO C.SEALING COAT: UNIFORMLY APPLY A CONTINUOUS SEALING COAT OF CURING1.4ACCESSORIES SHEETS. G.FASTENERS: HOT-DIP GALVANIZED STEEL WHERE EXPOSED TO WEATHER, IN NOT REFLECT ACTUAL SITE CONDITIONS. B.CONCRETE MATERIALS:AND SEALING COMPOUND TO HARDENED CONCRETE BY POWER SPRAY ORA.TRIM ACCESSORIES: MANUFACTURER'S STANDARD ONE-PIECE VINYL GROUND CONTACT, IN CONTACT WITH TREATED WOOD, OR IN AREA OF HIGH NEITHER PARTY SHALL HAVE ANY OBLIGATION 1.PORTLAND CEMENT: ASTMC150, TYPEI, GRAY, SUPPLEMENTROLLER ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS.EXTRUSIONS DESIGNED TO RETAIN AND COVER EDGES OF PANELS. RELATIVE HUMIDITY. NOR LIABILITY TO THE OTHER (EXCEPT STATED WITH THE FOLLOWING:D.PROTECT LIQUID FLOOR TREATMENT FROM DAMAGE AND WEAR DURING THEPROVIDE DIVISION BARS, INSIDE CORNERS,OUTSIDE CORNERS, AND CAPS H.METAL FRAMING ANCHORS: ABOVE) UNTIL A WRITTEN AGREEMENT IS a.FLY ASH: ASTMC618, CLASSF OR C.REMAINDER OF CONSTRUCTION PERIOD. USE PROTECTIVE METHODS ANDAS NEEDED TO CONCEAL EDGES. 1.METAL: GALVANIZED STEEL;HOT-DIP HEAVY GALVANIZED STEEL FOR FULLYEXECUTEDBYBOTHPARTIES b.GROUND GRANULATED BLAST-FURNACE SLAG: ASTMMATERIALS, INCLUDING TEMPORARY COVERING, RECOMMENDED IN WRITING1.COLOR: WHITE. WOOD-PRESERVATIVE-TREATED LUMBER AND WHERE INDICATED. C989, GRADE100 OR 120.BY LIQUID FLOOR TREATMENTS INSTALLER. END OF SECTION 064400 I.ADHESIVES: ADHESIVES SHALL HAVE A VOC CONTENT OF 70G/L OR LESS 2.AGGREGATE: NORMAL WEIGHT. END OF SECTION 033500 WHEN CALCULATED ACCORDING TO 40CFR59, SUBPARTD (EPA METHOD24). STARBUCKS TEMPLATE VERSION i2017.08.25 3.WATER: ASTMC94/C94M. 1.2INSTALLATION SECTION 035416 - HYDRAULIC-CEMENT-BASED UNDERLAYMENT 4.ADMIXTURES: PROVIDE ADMIXTURES CERTIFIED BY A.FURRING TO RECEIVE PLYWOOD OR HARDBOARD PANELING: 1-BY-3-INCH THERMAL AND MOISTURE PROTECTION 1.1SUMMARY MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES NOMINAL-SIZE (19-BY-63-MM ACTUAL-SIZE) FURRING AT 24 INCHES 610 MM O.C Design Forum A.HYDRAULIC-CEMENT-BASED UNDERLAYMENT FOR USE BELOW INTERIOR AND THAT WILL NOT CONTRIBUTE WATER-SOLUBLE CHLORIDE SECTION 07841 - THROUGH-PENETRATION FIRESTOP SYSTEMS FLOOR COVERINGS. IONS EXCEEDING THOSE PERMITTED IN HARDENED CONCRETE. B.FURRING TO RECEIVE GYPSUM BOARD: 1-BY-2-INCH NOMINAL-SIZE (19-BY-38- 1.1SUBMITTALS 1.2MATERIALS DO NOT USE CALCIUM CHLORIDE OR ADMIXTURES CONTAINING MM ACTUAL-SIZE) FURRING AT O.C. 16 INCHES 406 MM A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. Architects Inc. A.UNDERLAYMENT: HYDRAULIC-CEMENT-BASED, POLYMER-MODIFIED, SELF- CALCIUM CHLORIDE. END OF SECTION 061053 1.2QUALITY ASSURANCE 700 W. Pete Rose Way, Suite 460Donald J. Rethman LEVELING PRODUCT THAT CAN BE APPLIED IN MINIMUM UNIFORM THICKNESS a.AIR-ENTRAINMENT: ASTM C 260. A.INSTALLER QUALIFICATIONS: AN FM GLOBAL-APPROVED FIRESTOP Cincinnati, OH 45203Architect In Charge OF 1/4 INCH (6MM) AND THAT CAN BE FEATHERED AT EDGES TO MATCH b.WATER-REDUCING ADMIXTURE: ASTMC494/C494M, Tel: (513) 421-2210License: AR19700147 CONTRACTOR OR A UL-QUALIFIED FIRESTOP CONTRACTOR. ADJACENT FLOOR ELEVATIONS. TYPEA. SECTION 064000 - INTERIOR ARCHITECTURAL WOODWORK B.FIRE-TEST-RESPONSE CHARACTERISTICS: TESTED PER ASTM E 814 BY 1.CEMENT BINDER: PORTLAND CEMENT, OR OTHER HYDRAULIC OR c.HIGH-RANGE, WATER-REDUCING ADMIXTURE: ASTM 1.1SUMMARY QUALIFIED TESTING AND INSPECTING AGENCY. BLENDED HYDRAULIC CEMENT. C494/C494M, TYPEF. A.INTERIOR STANDING AND RUNNING TRIM. 1.3PENETRATION FIRESTOPPING Design Forum B.PRIMER: PRODUCT OF UNDERLAYMENT MANUFACTURER RECOMMENDED IN C.WATERSTOPS: FLEXIBLE RUBBER. B.FLUSH WOOD PANELINGAND WAINSCOTS. A.PENETRATIONS IN FIRE-RESISTANCE-RATED WALLS: F-RATINGS PER WRITING FOR SUBSTRATE, CONDITIONS, AND APPLICATION INDICATED. D.PLASTIC VAPOR RETARDER: ASTME1745, CLASSA. INCLUDE C.MELAMINE CABINETS. ASTM E 814 OR UL 1479. 1.PRIMER SHALL HAVE A VOC CONTENT OF 200G/L OR LESS WHEN MANUFACTURER'S RECOMMENDED ADHESIVE OR PRESSURE-SENSITIVE D.SOLID-SURFACING-MATERIAL COUNTERTOPS. Engineering B.PENETRATIONS IN HORIZONTAL ASSEMBLIES: F- AND T-RATINGS PER CALCULATED ACCORDING TO 40CFR59, SUBPARTD. JOINT TAPE. E.CLOSET AND UTILITY SHELVING. ASTM E 814 OR UL 1479: 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE END OF SECTION 035416 E.CURING MATERIALS: WATERBORNE, MONOMOLECULAR FILM FORMING, 1.2QUALITY ASSURANCE Cincinnati, OH 45203Professional Engineer C.PENETRATIONS IN SMOKE BARRIERS: L-RATINGS PER UL 1479. MANUFACTURED FOR APPLICATION TO FRESH CONCRETE. License: PE10504904 A.QUALITY STANDARD: AWI.Tel: (513) 421-2210 D.W-RATINGS: PER UL 1479. F.RELATED MATERIALS: 1.3MATERIALS E.VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS AND 1.EXPANSION- AND ISOLATION-JOINT-FILLER STRIPS ASTMD1751, A.WOOD PRODUCTS: COMPLY WITH THE FOLLOWING: SEALANT PRIMERS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC ASPHALT-SATURATED CELLULOSIC FIBER OR ASTMD1752, CORK 1.HARDBOARD: AHAA135.4, MADE WITH BINDER CONTAINING NO CONTENT WHEN CALCULATED ACCORDING TO 40CFR59, SUBPARTD OR SELF-EXPANDING CORK. UREA FORMALDEHYDE. (EPA METHOD24): 2.BONDING AGENT: ASTMC1059/C1059M, TYPEII, 2.MEDIUM-DENSITY FIBERBOARD: ANSIA208.2, GRADE130,MADE 1.SEALANTS: 250 G/L. NON-REDISPERSIBLE, ACRYLIC EMULSION OR STYRENE WITH BINDER CONTAINING NO UREA FORMALDEHYDE. 2.SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L. BUTADIENE. METALS 3.MOISTURE RESISTANT MEDIUM-DENSITY FIBERBOARD: 3.SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L. 3.NON-SHRINK GROUTS: ASTM C 1107, GRADE B; NON-SHRINK ANSIA208.2, GRADEMD,MR50, MADE WITH BINDER CONTAINING 1.4INSTALLATION SECTION 055000 - METAL FABRICATIONS NON-CATALYZED NATURAL AGGREGATE GROUT; MINIMUM NO UREA FORMALDEHYDE. A.IDENTIFICATION: PREPRINTED METAL OR PLASTIC LABELS, PERMANENTLY 1.1SUMMARY COMPRESSIVE STRENGTH OF 7000 PSI AT 28 DAYS; 25 TO 30 4.STRAW-BASED PARTICLEBOARD: ANSIA208.1, GRADEM-2, ATTACHED. A.STEEL FRAMING AND SUPPORTS FOR MECHANICAL AND ELECTRICAL SECOND FLOW WHEN TESTED IN ACCORDANCE WITH ASTM C 939 EXCEPT FOR DENSITY, MADE WITH ADHESIVE CONTAINING NO 1.5FIELD QUALITY CONTROL EQUIPMENT. AT 45 TO 90 DEGREES F; CEMENT GRAY IN COLOR UREA FORMALDEHYDE. A.INSPECTION OF INSTALLED FIRESTOP SYSTEMS: BY OWNER-ENGAGED B.STEEL FRAMING AND SUPPORTS FOR APPLICATIONS WHERE FRAMING AND 4.FORM RELEASE COATING: WATER BASED TYPE; VOC <150G/I; 11/01/17 09/01/17 5.SOFTWOOD PLYWOOD: DOCPS1 AGENCY ACCORDING TO ASTME2174 REQUIREMENTS. SUPPORTS ARE NOT SPECIFIED IN OTHER SECTIONS. NOX-CRETE ÐUTILITY RELEASE. CRESSET CHEMICAL COMPANY 6.VENEER-FACED PANEL PRODUCTS (HARDWOOD PLYWOOD): END OF SECTION 07841 C.SHELF ANGLES. CRETE 20_VOC,Ñ OR APPROVED; NON STAINING. HPVA HP-1,MADE WITH ADHESIVE CONTAINING NO UREA D.METAL BOLLARDS. G.REPAIR MATERIALS: FORMALDEHYDE. 1.2SUBMITTALS 1.REPAIR UNDERLAYMENT: CEMENT-BASED, POLYMER-MODIFIED, B.ADHESIVES, GENERAL: DO NOT USE ADHESIVES THAT CONTAIN SECTION 078446 - FIRE-RESISTIVE JOINT SYSTEMS A.PRODUCT DATA: FOR THE FOLLOWING: SELF-LEVELING PRODUCT THAT CAN BE APPLIED IN THICKNESSES UREA FORMALDEHYDE. L 1.1SUMMARY 1.PAINT PRODUCTS. FROM 1/8 INCH (3.2 MM) AND THAT CAN BE FEATHERED AT EDGES C.VOC LIMITS FOR INSTALLATION ADHESIVES AND GLUES: USE L A.FIRE-RESISTIVE JOINT SYSTEMS FOR THE FOLLOWING: 2.GROUT. TO MATCH ADJACENT FLOOR ELEVATIONS. INSTALLATION ADHESIVES THAT COMPLY WITH THE FOLLOWING LIMITS Y 1.JOINTS IN OR BETWEEN FIRE-RESISTANCE-RATED CONSTRUCTIONS. 3.ALL PREFABRICATED PRODUCTS. a.CEMENT BINDER: ASTMC150, PORTLAND CEMENT OR E FOR VOC CONTENT WHEN CALCULATED ACCORDING TO 40CFR59, 2.JOINTS AT EXTERIOR CURTAIN-WALL/FLOOR INTERSECTIONS. B.SHOP DRAWINGS: SHOW FABRICATION AND INSTALLATION DETAILS FOR HYDRAULIC OR BLENDED HYDRAULIC CEMENT AS DEFINED W SUBPARTD (EPA METHOD24): 3.JOINTS IN SMOKE BARRIERS.D METAL FABRICATIONS. IN ASTMC219. 1.WOOD GLUES: 30 G/L. K 1.2PERFORMANCE REQUIREMENTS 1.INCLUDE PLANS, ELEVATIONS, SECTIONS, AND DETAILS OF METAL b.PRIMER: PRODUCT OF UNDERLAYMENT MANUFACTURER 2.PANEL ADHESIVE: 50 G/L P L A.FIRE-RESISTANCE RATINGS OF JOINT SYSTEMS IN AND BETWEEN FIRE- FABRICATIONS AND THEIR CONNECTIONS. SHOW ANCHORAGE AND RECOMMENDED FOR SUBSTRATE, CONDITIONS, AND 3.MULTIPURPOSE CONSTRUCTION ADHESIVE: 70 G/L RESISTANCE-RATED CONSTRUCTIONS: EQUALING OR EXCEEDING THE L ACCESSORY ITEMS. APPLICATION. 4.CONTACT ADHESIVE: 80 G/L. E 3 FIRE-RESISTANCE RATINGS OF CONSTRUCTION THAT THEY JOIN, L 2.PROVIDE TEMPLATES FOR ANCHORS AND BOLTS SPECIFIED FOR c.AGGREGATE: WELL-GRADED, WASHED GRAVEL, 1/8 TO a.SPECIAL PURPOSE: 250 G/L 3 Z AS DETERMINED BY UL2079. INSTALLATION UNDER OTHER SECTIONS. E 1/4 INCH (3.2 TO 6 MM) OR COARSE SAND AS D.CLOSET AND UTILITY SHELVING: 0 1.3SUBMITTALS C.WELDING CERTIFICATES. RECOMMENDED BY UNDERLAYMENT MANUFACTURER. 1.GRADE: ECONOMY.A D6 A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 1.3PRODUCTS d.COMPRESSIVE STRENGTH: NOT LESS THAN 4100 PSI 4 2.SHELF MATERIAL: 3/4 INCH (19 MM) THERMOSET DECORATIVE L 1.4QUALITY ASSURANCE H A.MATERIALS: STEEL PLATES, SHAPES, AND BARS, STEEL PIPE, SLOTTED (29 MPA) AT 28 DAYS WHEN TESTED ACCORDING TO PANEL WITH PVC OR POLYESTER EDGE BANDING. A.FIRE-TEST-RESPONSE CHARACTERISTICS: TESTED BY QUALIFIED TESTING E N CHANNEL FRAMING. ASTMC109/C109M. 3.CLEATS: 3/4 INCH (19 MM) PANEL PRODUCT. I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt AND INSPECTING AGENCY. Z 1.LOW-EMITTING PRIMER: METAL PRIMER SHALL HAVE A VOC CONTENT & 2.REPAIR OVERLAYMENT: CEMENT-BASED, POLYMER-MODIFIED, E.SHOP FINISHING: , 1.5FIRE-RESISTIVE JOINT SYSTEMS OF 200G/L OR LESS WHEN CALCULATED ACCORDING TO 40CFR59, A SELF-LEVELING PRODUCT HAT CAN BE APPLIED IN THICKNESSES 1.GRADE: SAME GRADE AS WOODWORK. L A.DESIGNATION SYSTEM FOR JOINTS IN OR BETWEEN FIRE-RESISTANCE-RATED SUBPARTD (EPA METHOD24). FROM 1/8 INCH (3.2 MM) AND THAT CAN BE FEATHERED AT EDGES T 2.EXTENT: ALL WOODWORK SHOP FINISHED. H E CONSTRUCTIONS: ALPHANUMERIC SYSTEMS LISTED IN UL'S "FIRE B.MISCELLANEOUS FRAMING AND SUPPORTS: TO MATCH ADJACENT FLOOR ELEVATIONS. 1.4INSTALLATION S 0 RESISTANCE DIRECTORY" UNDER PRODUCT CATEGORYXHBN. M 1.STEEL FRAMING AND SUPPORTS FOR MECHANICAL AND ELECTRICAL a.CEMENT BINDER: ASTMC150, PORTLAND CEMENT OR A.SCRIBE AND CUT MILLWORK TO FIT ADJOINING WORK, REFINISH CUT 7 B.JOINTS IN OR BETWEEN FIRE-RESISTANCE-RATED CONSTRUCTION: EQUAL TO 1 EQUIPMENT, APPLICATIONS WHERE FRAMING AND SUPPORTS ARE HYDRAULIC OR BLENDED HYDRAULIC CEMENT AS DEFINED R SURFACES, AND REPAIR DAMAGED FINISH AT CUTS. 1 OR EXCEEDING THE FIRE-RESISTANCE RATING OF CONSTRUCTION THEY WILL NOT SPECIFIED IN OTHER SECTIONS. IN ASTMC219. 3 B.ANCHOR MILLWORK TO ANCHORS OR BLOCKING BUILT IN OR DIRECTLY A 3 JOIN. 2.GALVANIZE WHERE INDICATED. b.PRIMER: PRODUCT OF TOPPING MANUFACTURER ATTACHED TO SUBSTRATES. SECURE WITH COUNTERSUNK, 1 1C C.JOINTS AT EXTERIOR CURTAIN-WALL/FLOOR INTERSECTIONS: EQUAL TO OR 3.PRIME WITH ZINC-RICH PRIMER WHERE INDICATED. RECOMMENDED FOR SUBSTRATE, CONDITIONS, AND CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR EXCEEDING THE FIRE-RESISTANCE RATING OF THE FLOOR ASSEMBLY. a.ZINC-RICH PRIMER SHALL HAVE A VOC CONTENT OF 340G/L APPLICATION. COMPLETE INSTALLATION. USE FINE FINISHING NAILSOR FINISHING D.JOINTS IN SMOKE BARRIERS: OR LESS WHEN CALCULATED ACCORDING TO 40CFR59, STORE #:8123 c.AGGREGATE: WELL-GRADED, WASHED GRAVEL, 1/8 TO SCREWS FOR EXPOSED FASTENING, COUNTERSUNK AND FILLED FLUSH 1.L-RATING: NOT EXCEEDING 5.0 CFM/FT (0.00775 CU. M/S X M) OF JOINT SUBPARTD (EPA METHOD24). 1/4 INCH (3.2 TO 6 MM) OR COARSE SAND AS WITH MILLWORK AND MATCHING FINAL FINISH IF TRANSPARENT FINISH PROJECT #:25450-048 AT 0.30 INCH WG (74.7 PA) AT BOTH AMBIENT AND ELEVATED C.LOOSE STEEL LINTELS, GALVANIZED AT EXTERIOR WALLS. RECOMMENDED BY TOPPING MANUFACTURER. IS INDICATED. TEMPERATURES. D.SHELF ANGLES, GALVANIZED. ISSUE DATE: 11/1/17 d.COMPRESSIVE STRENGTH: NOT LESS THAN 5000 PSI C.CABINETS: INSTALL WITHOUT DISTORTION SO DOORS AND DRAWERS FIT E.EXPOSED FIRE-RESISTIVE JOINT SYSTEMS: PROVIDE PRODUCTS WITH E.STEEL WELD PLATES AND ANGLES NOT SPECIFIED IN OTHER SECTIONS, FOR DESIGNER: LISA MACEDA (34.5 MPA) AT 28 DAYS WHEN TESTED ACCORDING TO OPENINGS PROPERLY AND ARE ACCURATELY ALIGNED. ADJUST R FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES OF LESS THAN 25 AND 450, CASTING INTO CONCRETE. LEED AP: ASTMC109/C109M. HARDWARE TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO RESPECTIVELY, AS DETERMINED PER ASTME84. F.METAL BOLLARDS: SCHEDULE40 STEEL PIPE. PRODUCTION DESIGNER: PETER CHEETHAM 1.4INSTALLATION PROVIDE UNENCUMBERED OPERATION. COMPLETE INSTALLATION OF F.VOC CONTENT: FIRE-RESISTIVE JOINT SYSTEM SEALANTS SHALL COMPLY END OF SECTION 055000 CHECKED BY: A.FLOOR AND SLAB FINISHES: HARDWARE AND ACCESSORY ITEMS AS INDICATED. WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN CALCULATED 1.FLOAT: SURFACES TO RECEIVE TROWEL FINISH. 1.INSTALL CABINETS WITH NO MORE THAN 1/8 INCH IN 96 INCH ACCORDING TO 40CFR59, SUBPARTD (EPA METHOD24): 2.TROWEL: SURFACES EXPOSED TO VIEW, AND SURFACES TO BE (3 MM IN 2400 MM) SAG, BOW, OR OTHER VARIATION FROM A Revision Schedule 1.ARCHITECTURAL SEALANTS: 250G/L. COVERED WITH RESILIENT FLOORING, CARPET, CERAMIC OR STRAIGHT LINE. 2.SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250G/L. QUARRY TILE SET OVER A CLEAVAGE MEMBRANE, PAINT, OR D.COUNTERTOPS: ANCHOR SECURELY BY SCREWING THROUGH CORNER RevDateByDescription G.SEALANT PRIMERS FOR POROUS SUBSTRATES: 775G/L. ANOTHER THIN-FILM-FINISH COATING SYSTEM. BLOCKS OF BASE CABINETS OR OTHER SUPPORTS INTO UNDERSIDE OF H.ACCESSORIES: FORMING MATERIALS AND OTHER COMPONENTS NEEDED 3.TROWEL AND FINE BROOM: SURFACES TO BE COVERED WITH COUNTERTOP. TO INSTALL FILL MATERIALS AND MAINTAIN RATINGS REQUIRED. CERAMIC OR QUARRY TILE INSTALLED BY EITHER THICKSET OR 1.ALIGN ADJACENT SOLID-SURFACING-MATERIAL COUNTERTOPS END OF SECTION 078446 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st THIN-SET METHOD. AND FORM SEAMS TO COMPLY WITH MANUFACTURER'S WRITTEN 4.BROOM: EXTERIOR CONCRETE PLATFORMS, STEPS, AND RAMPS. RECOMMENDATIONS USING ADHESIVE IN COLOR TO MATCH 1.5FIELD QUALITY CONTROL COUNTERTOP. CAREFULLY DRESS JOINTS SMOOTH, REMOVE A.TESTING: BY CONTRACTOR-ENGAGED AGENCY. SURFACE SCRATCHES, AND CLEAN ENTIRE SURFACE. B.INSPECTIONS: BY OWNER-ENGAGED SPECIAL INSPECTOR. 2.INSTALL COUNTERTOPS WITH NO MORE THAN 1/8 INCH IN 96 INCH SHEET TITLE: END OF SECTION 033000 (3 MM IN 2400 MM) SAG, BOW, OR OTHER VARIATION FROM A STRAIGHT LINE. CONSTRUCTION 3.SECURE COVED BACKSPLASHES TO TOPS PER MANUFACTURES FABRICATION MANUAL AND TO WALLS WITH ADHESIVE. SPECIFICATIONS 4.CALK SPACE BETWEEN BACKSPLASH AND WALL WITH SEALANT NO SCALE SCALE: SPECIFIED IN DIVISION7 SECTION "JOINT SEALANTS." END OF SECTION 064000 SHEET NUMBER: G-0011 10/31/2017 6:18:20 PM THERMAL AND MOISTURE PROTECTION (CONT)DOORS AND WINDOWS (CONTINUED)FINISHESFINISHES (CONTINUED) SECTION 079200 - JOINT SEALANTSSECTION 09216 - NON-LOAD-BEARING STEEL FRAMINGSECTION 093000 - CERAMIC TILE 1.1MATERIALS1.1SUMMARY1.1SUMMARY SECTION 08345 - DOUBLE ACTING SWING DOORS A.VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS ANDA.NON-LOAD-BEARING STEEL FRAMING MEMBERS FOR INTERIOR FRAMINGA.PAVER, GLAZED, AND WALL TILE. PART 1 - GENERAL SEALANT PRIMERS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOCSYSTEMS.B.WATERPROOF MEMBRANE FOR THIN-SET TILE INSTALLATIONS. 1.1SUMMARY CONTENT WHEN CALCULATED ACCORDING TO 40CFR59, SUBPARTD1.2MATERIALSC.METAL EDGE STRIPS INSTALLED AS PART OF TILE INSTALLATIONS. A.SECTION INCLUDES: (EPA METHOD24):A.STEEL FRAMING FOR FRAMED ASSEMBLIES:1.2QUALITY ASSURANCE 1.SOLID-CORE DOUBLE ACTING SWING DOORS WITH PLASTIC 1.SEALANTS: 250 G/L.B.FRAMING MEMBERS, GENERAL: COMPLY WITH ASTMC754 FOR CONDITIONS A.MOCKUPS FOR EACH FORM OF CONSTRUCTION. LAMINATE FACES. 2.SEALANT PRIMERS FOR NONPOROUS SUBSTRATES: 250 G/L.INDICATED.1.3MATERIALS 1.2SUBMITTALS 3.SEALANT PRIMERS FOR POROUS SUBSTRATES: 775 G/L.1.STEEL SHEET COMPONENTS: COMPLY WITH ASTMC645A.GLAZED WALL TILE TRIM SHAPES: COVED BASE, BULLNOSE CAP. A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE R B.SUITABILITY FOR CONTACT WITH FOOD: WHERE SEALANTS ARE INDICATEDREQUIREMENTS FOR METAL, UNLESS OTHERWISE INDICATED.B.THRESHOLDS: SATIN ANODIZED ALUMINUM THRESHOLDS AND TRANSITION CONSTRUCTION DETAILS, MATERIAL DESCRIPTIONS, CORE FOR JOINTS THAT WILL COME IN REPEATED CONTACT WITH FOOD, PROVIDE2.PROTECTIVE COATING: COATING WITH EQUIVALENT CORROSIONSTRIPS. DESCRIPTIONS, FIRE-RESISTANCE RATING, TEMPERATURE-RISE C 2017 STARBUCKS COFFEE COMPANY PRODUCTS THAT COMPLY WITH 21CFR177.2600.RESISTANCE OF ASTMA653/A653M, G40 (Z120), HOT-DIP1.BEVEL EDGES AT 1:2 SLOPE, WITH LOWER EDGE OF BEVEL ALIGNED RATINGS, AND FINISHES. C.ELASTOMERIC JOINT SEALANTS: LIQUID APPLIED, CHEMICALLY CURING;GALVANIZED, UNLESS OTHERWISE INDICATED.WITH OR UP TO 1/16 INCH (1.5 MM) ABOVE ADJACENT FLOOR B.SHOP DRAWINGS: INCLUDE THE FOLLOWING: ASTM C 920.1.3STEEL FRAMING FOR FRAMED ASSEMBLIESSURFACE. FINISH BEVEL TO MATCH TOP SURFACE OF THRESHOLD. 1.ELEVATIONS OF EACH DOOR DESIGN. STARBUCKS COFFEE 1.MULTICOMPONENT NONSAG NEUTRAL-CURING SILICONE SEALANTA.SALVAGED MATERIAL: USE SALVAGED FRAMING MATERIALS WHENEVERLIMIT HEIGHT OF THRESHOLD TO 1/2 INCH (12.7 MM) OR LESS ABOVE 2.DETAILS OF DOORS, INCLUDING VERTICAL AND HORIZONTAL ES-1.AVAILABLE.ADJACENT FLOOR SURFACE. EDGE DETAILS AND METAL THICKNESSES. COMPANY 2.SINGLE-COMPONENT MILDEW-RESISTANT NEUTRAL-CURINGB.STEEL STUDS AND RUNNERS: ASTMC645.C.MORTAR: LATEX-PORTLAND CEMENT 3.FRAME DETAILS FOR EACH FRAME TYPE, INCLUDING 2401 UTAH AVENUE SOUTH SILICONE SEALANT ES-2.1.MINIMUM BASE-METAL THICKNESS: 0.033 INCH (0.84 MM) UNLESSD.ELASTOMERIC SEALANTS: ONE-PART, MILDEW-RESISTANT SILICONE. DIMENSIONED PROFILES AND METAL THICKNESSES. 3.SINGLE-COMPONENT MILDEW-RESISTANT ACID-CURING SILICONEOTHERWISE INDICATED ON DRAWINGS.1.SEALANTS SHALL HAVE A VOC CONTENT OF 250 4.LOCATIONS OF REINFORCEMENT AND PREPARATIONS FOR SEATTLE, WASHINGTON 98134 SEALANT ES-3.2.DEPTH: AS INDICATED ON DRAWINGS. G/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, HARDWARE. (206) 318-1575 4.SINGLE-COMPONENT MILDEW-RESISTANT ACID-CURING RTVC.DIMPLED STEEL STUDS AND RUNNERS: SUBPART D (EPA METHOD 24). 5.DETAILS OF ACCESSORIES. SILICONE SEALANT ES-4.1.MINIMUM BASE-METAL THICKNESS: 0.025 INCH (0.64 MM). 1.4FLOOR TILE INSTALLATION SCHEDULE 6.DETAILS OF MOLDINGS, REMOVABLE STOPS, AND GLAZING. THESE DRAWINGS AND SPECIFICATIONS ARE 5.MULTICOMPONENT NONSAG POLYUREA SEALANT ES-5.2.DEPTH: AS INDICATED ON DRAWINGS. A.INTERIOR FLOORS ON CONCRETE: THIN-SET MORTAR. 1.3STANDARD DOUBLE ACTING SWING DOORS CONFIDENTIAL AND SHALL REMAIN THE SOLE 6.MULTICOMPONENT NONSAG POLYUREA FILLER ES-6.D.SLIP-TYPE HEAD JOINTS: WHERE INDICATED, PROVIDEONE OF THE 1.TILE TYPE: UNGLAZED PAVER TILE. A.GENERAL: PROVIDE DOORS OF DESIGN INDICATED, NOT LESS THAN PROPERTY OF STARBUCKS CORPORATION, D.LATEX SEALANT LS-1: COMPLY WITH ASTMC834, TYPEP, GRADENF.FOLLOWING: 2.MORTAR: LATEX- PORTLAND CEMENT MORTAR BOND COAT. THICKNESS INDICATED; FABRICATED WITH SMOOTH SURFACES, WHICH IS THE OWNER OF THE COPYRIGHT IN E.JOINT-SEALANT BACKING:1.SINGLE LONG-LEG RUNNER SYSTEM: ASTMC645 TOP RUNNER 3.GROUT: POLYMER-MODIFIED UNSANDED 100% SOLIDS EPOXY WITHOUT VISIBLE JOINTS OR SEAMS ON EXPOSED FACES UNLESS THIS WORK. THEY SHALL NOT BE 1.2JOINT-SEALANT SCHEDULEWITH 2 INCH (50.8 MM) DEEP FLANGES IN THICKNESS NOT LESS NON-SAGGING GROUT. OTHERWISE INDICATED. COMPLY WITH ANSI/SDIA250.8. REPRODUCED (IN WHOLE OR IN PART), SHARED A.JOINT-SEALANT APPLICATION JS-1: EXTERIOR HORIZONTAL NONTRAFFICTHAN INDICATED FOR STUDS, INSTALLED WITH STUDS FRICTION FIT B.INTERIOR FLOORS ON CRACK-SUPPRESSION MEMBRANE 1.DESIGN: AS INDICATED. WITH THIRD PARTIES OR USED IN ANY MANNER INTO TOP RUNNER AND WITH CONTINUOUS BRIDGING LOCATED AND TRAFFIC ISOLATION AND CONTRACTION JOINTS IN CAST-IN-PLACE OVER CONCRETE AND WOOD: THIN-SET MORTAR. B.CORE CONSTRUCTION: 3/4 INCH (19 MM) EXTERIOR GRADE SOLID WOOD ON OTHER PROJECTS OR EXTENSIONS TO THIS CONCRETE SLABS.WITHIN 12 INCHES (305 MM) OF THE TOP OF STUDS TO PROVIDE 1.TILE TYPE: UNGLAZED PAVER TILE. CORE MADE WITH ADHESIVES AND COMPOSITE WOOD PRODUCTS THAT PROJECT WITHOUT THE PRIOR WRITTEN 1.JOINT SEALANT: ES-5.LATERAL BRACING. 2.MORTAR: LATEX- PORTLAND CEMENT MORTAR BOND COAT. DO NOT CONTAIN UREA FORMALDEHYDE. CONSENT OF STARBUCKS CORPORATION. B.JOINT-SEALANT APPLICATION JS-2: EXTERIOR PERIMETER JOINTS BETWEEN2.DOUBLE-RUNNER SYSTEM: ASTMC645 TOP RUNNERS, INSIDE 3.GROUT: POLYMER-MODIFIED UNSANDED 100% SOLIDS EPOXY 1.VERTICAL EDGES FOR DOUBLE-ACTING DOORS: ROUND THESE DRAWINGS AND SPECIFICATIONS ARE WALL AND FRAMES OF DOORS AND WINDOWS.RUNNER WITH 2 INCH (50.8 MM) DEEP FLANGES IN THICKNESS NOT NON-SAGGING GROUT. VERTICAL EDGES WITH 2-1/8 INCH (54 MM) RADIUS. INTENDED TO EXPRESS DESIGN INTENT FOR A 1.JOINT SEALANT: ES-1.LESS THAN INDICATED FOR STUDS AND FASTENED TO STUDS, AND 1.5WALL TILE INSTALLATION SCHEDULE 2.TOP AND BOTTOM EDGES: CLOSED WITH FLUSH OR INVERTED PROTOTYPICAL STARBUCKS STORE (WHICH IS C.JOINT-SEALANT APPLICATION JS-3: EXTERIOR CONTROL AND EXPANSIONOUTER RUNNER SIZED TO FRICTION FIT INSIDE RUNNER. A.INTERIOR WALLS OVER GLASS-MAT WATER-RESISTANT BACKER BOARD OR 0.042 INCH (1.0 MM) THICK, END CLOSURES OR CHANNELS OF SUBJECT TO CHANGE AT ANYTIME) AND DO JOINTS IN HORIZONTAL TRAFFIC SURFACES OF BRICK PAVERS, CERAMIC3.DEFLECTION TRACK: STEEL SHEET TOP RUNNER MANUFACTURED CEMENTITIOUS BACKER UNITS: THIN-SET MORTAR. SAME MATERIAL AS FACE SHEETS. NOT REFLECT ACTUAL SITE CONDITIONS. TILE, STONE PAVING UNITS, CONCRETE TILE.TO PREVENT CRACKING OF FINISHES APPLIED TO INTERIOR 1.TILE TYPE: UNGLAZED CERAMIC AND 3.TOLERANCES: COMPLY WITH SDI117, "MANUFACTURING NEITHER PARTY SHALL HAVE ANY OBLIGATION 1.JOINT SEALANT: MULTICOMPONENT POURABLE POLYSULFIDEPARTITION FRAMING RESULTING FROM DEFLECTION OF STRUCTURE TOLERANCES FOR STANDARD STEEL DOORS AND FRAMES." GLAZED WALL TILE. NOR LIABILITY TO THE OTHER (EXCEPT STATED SEALANT.ABOVE; IN THICKNESS NOT LESS THAN INDICATED FOR STUDS AND C.INTERIOR DOORS: FACE SHEETS FABRICATED FROM DECORATIVE HIGH 2.MORTAR: LATEX- PORTLAND CEMENT MORTAR. ABOVE) UNTIL A WRITTEN AGREEMENT IS 2.JOINT-SEALANT COLOR: AS SELECTED BY ARCHITECT FROMIN WIDTH TO ACCOMMODATE DEPTH OF STUDS. PRESSURE LAMINATE. PROVIDE DOORS COMPLYING WITH 3.GROUT: POLYMER-MODIFIED UNSANDED GROUT. FULLYEXECUTEDBYBOTHPARTIES MANUFACTURER'S FULL RANGE.E.COLD-ROLLED CHANNEL BRIDGING: 0.0538 INCH (1.37 MM) BARE-STEEL REQUIREMENTS INDICATED BELOW BY REFERENCING ANSI/SDIA250.8 END OF SECTION 093000 D.JOINT-SEALANT APPLICATION JS-4: INTERIOR PERIMETER JOINTS OFTHICKNESS, WITH MINIMUM 1/2 INCH (12.7 MM) WIDE FLANGES. FOR LEVEL AND MODEL AND ANSI/SDIA250.4 FOR PHYSICAL SECTION 095113 - ACOUSTICAL PANEL CEILINGS STARBUCKS TEMPLATE VERSION i2017.08.25 EXTERIOR OPENINGS.1.DEPTH: 1-1/2 INCHES (38.1 MM). PERFORMANCE LEVEL: 1.1SUMMARY 1.JOINT SEALANT: ES-3.2.CLIP ANGLE: NOT LESS THAN 1-1/2 BY 1-1/2 INCHES (38.1 BY 1.LEVEL1 AND PHYSICAL PERFORMANCE LEVELC A.ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS. E.JOINT-SEALANT APPLICATION JS-5: INTERIOR CERAMIC TILE EXPANSION,38.1 MM), 0.068 INCH (1.73 MM) THICK, GALVANIZED STEEL. (STANDARD DUTY). 1.2SUBMITTALS CONTROL, CONTRACTION, AND ISOLATION JOINTS IN HORIZONTAL TRAFFICF.HAT-SHAPED, RIGID FURRING CHANNELS: ASTMC645. a.WIDTH: AS INDICATED ON DRAWINGS. A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.Design Forum SURFACES.1.MINIMUM BASE METAL THICKNESS: AS INDICATED ON DRAWINGS. D.HARDWARE REINFORCEMENT: FABRICATE ACCORDING TO B.COORDINATION DRAWINGS: REFLECTED CEILING PLANS, DRAWN TO SCALE, 1.JOINT SEALANT: ES-3.2.DEPTH: AS INDICATED ON DRAWINGS. ANSI/SDIA250.6 WITH REINFORCING PLATES OF 18 GAUGE STAINLESS ON WHICH THE FOLLOWING ITEMS ARE SHOWN AND COORDINATED WITH 2.JOINT-SEALANT COLOR: AS NOTED.G.COLD-ROLLED FURRING CHANNELS: 0.0538 INCH (1.37 MM) BARE-STEEL STEEL Architects Inc. EACH OTHER, BASED ON INPUT FROM INSTALLERS OF THE ITEMS F.JOINT-SEALANT APPLICATION JS-6: INTERIOR JOINTS BETWEEN PLUMBINGTHICKNESS, WITH MINIMUM 1/2 INCH (12.7 MM) WIDE FLANGES. E.FABRICATE CONCEALED STIFFENERS AND HARDWARE REINFORCEMENT INVOLVED: 700 W. Pete Rose Way, Suite 460Donald J. Rethman FIXTURES AND ADJOINING WALLS, FLOORS, AND COUNTERS.1.DEPTH: AS INDICATED ON DRAWINGS. Cincinnati, OH 45203Architect In Charge FROM EITHER COLD- OR HOT-ROLLED STEEL SHEET. 1.CEILING SUSPENSION SYSTEM MEMBERS. Tel: (513) 421-2210License: AR19700147 1.JOINT SEALANT: ES-3.2.FURRING BRACKETS: ADJUSTABLE, CORRUGATED-EDGE TYPE OF 1.4STOPS AND MOLDINGS 2.METHOD OF ATTACHING HANGERS TO BUILDING STRUCTURE. 2.JOINT-SEALANT COLOR: TRANSLUCENT.STEEL SHEET WITH MINIMUM BARE-STEEL THICKNESS OF A.MOLDINGS FOR GLAZED LITES IN DOORS: 3.CEILING-MOUNTED ITEMS INCLUDING LIGHTING FIXTURES, G.JOINT-SEALANT APPLICATION JS-7: VERTICAL JOINTS ON EXPOSED0.0312 INCH (0.79 MM). MINIMUM 0.032 INCH (0.8 MM) THICK. DIFFUSERS, GRILLES, SPEAKERS, SPRINKLERS, ACCESS PANELS, SURFACES OF INTERIOR PARTITIONS.3.TIE WIRE: ASTMA641/A641M, CLASS1 ZINC COATING, SOFT B.LOOSE STOPS FOR GLAZED LITES IN FRAMES: Design Forum AND SPECIAL MOLDINGS. TEMPER, 0.0625 INCH (1.59 MM) DIAMETER WIRE, OR DOUBLE 1.JOINT SEALANT: ES-3. MINIMUM 0.032 INCH (0.8 MM) THICK, FABRICATED FROM SAME MATERIAL C.SAMPLES FOR VERIFICATION: FOR EACH COMPONENT INDICATED AND FOR H.JOINT-SEALANT APPLICATION JS-8: PERIMETER JOINTS BETWEEN INTERIORSTRAND OF 0.0475 INCH (1.21 MM) DIAMETER WIRE. AS FRAMES IN WHICH THEY ARE INSTALLED. EACH EXPOSED FINISH REQUIRED, PREPARED ON SAMPLES OF SIZE Engineering WALL SURFACES AND FRAMES OF INTERIOR DOORS, WINDOWS.H.Z-SHAPED FURRING: WITH SLOTTED OR NONSLOTTED WEB, FACE FLANGE 1.5STEEL FINISHES INDICATED BELOW. 1.JOINT SEALANT: ES-3.OF 1-1/4 INCHES (31.8 MM), WALL ATTACHMENT FLANGE OF 7/8 INCH A.PRIME FINISH: APPLY MANUFACTURER'S STANDARD PRIMER 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 1.ACOUSTICAL PANEL: SET OF FULL-SIZE SAMPLES OF EACH TYPE, Cincinnati, OH 45203Professional Engineer I.JOINT-SEALANT APPLICATION JS-9: HVAC JOINTS.(22.2 MM), MINIMUM BARE-METAL THICKNESS OF 0.0179 INCH (0.45 MM), AND IMMEDIATELY AFTER CLEANING AND PRETREATING. COLOR, PATTERN, AND TEXTURE. License: PE10504904 Tel: (513) 421-2210 1.JOINT SEALANT: ES-2.DEPTH REQUIRED TO FIT INSULATION THICKNESS INDICATED. 1.SHOP PRIMER: MANUFACTURER'S STANDARD, FAST-CURING, 2.EXPOSED SUSPENSION SYSTEM MEMBERS, MOLDINGS, AND TRIM: 2.JOINT-SEALANT COLOR: ALUMINUM. END OF SECTION 09216 LEAD- AND CHROMATE-FREE PRIMER COMPLYING WITH SET OF 12 INCH (300 MM) LONG SAMPLES OF EACH TYPE, FINISH, J.JOINT-SEALANT APPLICATION JS-10: NON-POROUS MATERIAL TO SECTION 092900 - GYPSUM BOARD ANSI/SDIA250.10 ACCEPTANCE CRITERIA; RECOMMENDED BY AND COLOR. NON-POROUS MATERIAL. PRIMER MANUFACTURER FOR SUBSTRATE; COMPATIBLE WITH1.1SUMMARY D.QUALIFICATION DATA: FOR TESTING AGENCY. 1.JOINT SEALANT: ES-4. A.INTERIOR GYPSUM BOARD. SUBSTRATE AND FIELD-APPLIED COATINGS DESPITE E.FIELD QUALITY-CONTROL TEST REPORTS. 2.JOINT-SEALANT COLOR: CLEAR. B.TILE BACKING PANELS. PROLONGED EXPOSURE. F.PRODUCT TEST REPORTS: BASED ON EVALUATION OF COMPREHENSIVE END OF SECTION 079200 B.FACTORY-APPLIED PAINT FINISH: MANUFACTURER'S STANDARD,1.2SUBMITTALS TESTS PERFORMED BY A QUALIFIED TESTING AGENCY, FOR EACH A.PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. COMPLYING WITH ANSI/SDIA250.3 FOR PERFORMANCE AND ACOUSTICAL PANEL CEILING. B.SAMPLES: FOR THE FOLLOWING PRODUCTS: ACCEPTANCE CRITERIA. G.MAINTENANCE DATA: FOR FINISHES TO INCLUDE IN MAINTENANCE DOORS AND WINDOWS 1.6COLOR AND GLOSS: AS INDICATED BY MANUFACTURER'S DESIGNATIONS.1.TEXTURED FINISHES: MANUFACTURER'S STANDARD SIZE FOR EACH MANUALS. TEXTURED FINISH INDICATED AND ON SAME BACKING INDICATED END OF SECTION 08345 1.3QUALITY ASSURANCE SECTION 081416 - FLUSH WOOD DOORS FOR WORK. A.ACOUSTICAL PANEL QUALITY STANDARD: ASTME1264. 1.1SUBMITTALS 1.3MATERIALS B.METAL SUSPENSION SYSTEM QUALITY STANDARD: ASTMC635. A.PRODUCT DATA: FOR EACH TYPE OF DOOR INDICATED. INCLUDE DETAILS 11/01/17 09/01/17 A.INTERIOR GYPSUM BOARD: 1.4MATERIALS OF CORE AND EDGE CONSTRUCTION AND TRIM FOR OPENINGS. 1.GENERAL: COMPLYING WITH ASTMC36/C36M OR A.ACOUSTICAL CEILING PANELS GENERAL: MUST BE CERTIFIED AS LOW B.SHOP DRAWINGS: INDICATE LOCATION, SIZE, AND HAND OF EACH DOOR; ASTMC1396/C1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD EMITTING. CERTIFICATION MUST BE BASED UPON THE CALIFORNIA ELEVATION OF EACH KIND OF DOOR; CONSTRUCTION DETAILS NOT INDICATED AND WHICHEVER IS MORE STRINGENT. DEPARTMENT OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE COVERED IN PRODUCT DATA; LOCATION AND EXTENT OF HARDWARE a.MUST BE CERTIFIED AS LOW EMITTING. CERTIFICATION TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES USING BLOCKING; AND OTHER PERTINENT DATA. L MUST BE BASED UPON THE CALIFORNIA DEPARTMENT OF SMALL-SCALE ENVIRONMENTAL CHAMBERS", INCLUDING 2004 ADDENDA OR A 1.INDICATE DIMENSIONS AND LOCATIONS OF MORTISES AND HOLES L HEALTH SERVICES' "STANDARD PRACTICE FOR THE JURISDICTIONALLY RECOGNIZED STANDARD USING EQUIVALENT TESTING FOR HARDWARE. Y TESTING OF VOLATILE ORGANIC EMISSIONS FROM METHODOLOGIES AND VOC THRESHOLDS. 2.INDICATE DIMENSIONS AND LOCATIONS OF CUTOUTS. E VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL B.ACOUSTICAL CEILING PANELS WASHABLE 3.INDICATE REQUIREMENTS FOR VENEER MATCHING. W CHAMBERS", INCLUDING 2004 ADDENDA OR A 1.CLASSIFICATION: TYPEIV, MINERAL BASE WITH MEMBRANE-FACED D 4.INDICATE DOORS TO BE FACTORY FINISHED AND FINISH K JURISDICTIONALLY RECOGNIZED STANDARD USING OVERLAY; FORM2, WATER FELTED; WITH VINYL OVERLAY ON FACE; REQUIREMENTS. P VALENT TESTING METHODOLOGIES AND VOC THRESHOLDS. L PATTERN G (SMOOTH). 5.INDICATE FIRE-PROTECTION RATINGS FOR FIRE-RATED DOORS. 2.TYPEX: 2.COLOR: AS INDICATED ON DRAWINGS. C.WARRANTY: SAMPLE OF SPECIAL WARRANTY.L E 3 a.THICKNESS: 5/8 INCH (15.9 MM). 3.THICKNESS: 5/8 INCH (15 MM). L 1.2QUALITY ASSURANCE 3 b.LONG EDGES: TAPERED. Z 4.MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM). A.QUALITY STANDARD: AWI. E 0 3.MOISTURE- AND MOLD-RESISTANT TYPE: WITH MOISTURE- AND 5.BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE 1.AWI QUALITY CERTIFICATION LABELS OR AN AWI LETTER OF A D6 MOLD-RESISTANT CORE AND SURFACES. TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH LICENSING FOR DOORS. 4 a.CORE: 5/8 INCH (15.9 MM), TYPEX.L MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT H 2.WI-CERTIFIED COMPLIANCE CERTIFICATE FOR DOORS AND b.LONG EDGES: TAPERED. INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM-POSITIVE AND E INSTALLATION.N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt c.MOLD RESISTANCE: ASTMD3273, SCORE OF 10 AS RATED GRAM-NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR Z B.FIRE-RATED WOOD DOORS: POSITIVE PRESSURE TESTING. & , ACCORDING TO ASTMD3274. BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTMD3273 1.3DOOR CONSTRUCTION, GENERAL A L B.TILE-BACKING PANELS: AND EVALUATED ACCORDING TO ASTMD3274 OR ASTMG21. A.LOW-EMITTING MATERIALS: MADE WITH ADHESIVES AND COMPOSITE WOOD T H E 1.GLASS-MAT, WATER-RESISTANT BACKING BOARD: C.ACOUSTICAL CEILING PANELS TEXTURED: PRODUCTS THAT DO HAVE NO ADDED UREA FORMALDEHYDE. S ASTMC1178/C1178M, WITH MANUFACTURER'S STANDARD EDGES.0 1.CLASSIFICATION: TYPEIII, MINERAL BASE WITH PAINTED FINISH; M B.WDMA I.S.1-A PERFORMANCE GRADE: HEAVY DUTY UNLESS OTHERWISE 7 a.MUST BE CERTIFIED AS LOW EMITTING. CERTIFICATION FORM2, WATER FELTED; PATTERN E (LIGHTLY TEXTURED). INDICATED.1 R 1 MUST BE BASED UPON THE CALIFORNIA DEPARTMENT OF 2.COLOR: AS INDICATED ON DRAWINGS. 1.4VENEERED-FACED DOORS FOR TRANSPARENT FINISH 3 A 3 HEALTH SERVICES' "STANDARD PRACTICE FOR THE 3.THICKNESS: 5/8 INCH (15 MM). A.INTERIOR SOLID-CORE DOORS: 1 1C TESTING OF VOLATILE ORGANIC EMISSIONS FROM 4.MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM). 1.CORE: PARTICLEBOARD. VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL 5.BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE 2.CONSTRUCTION: FIVE OR SEVEN PLIES, BONDED. CHAMBERS", INCLUDING 2004 ADDENDA OR A TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH 1.5PRIMING/FINISHING STORE #:8123 JURISDICTIONALLY RECOGNIZED STANDARD USING MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT A.SHOP PRIMING: PROJECT #:25450-048 EQUIVALENT TESTING METHODOLOGIES AND VOC INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM-POSITIVE AND 1.DOORS FOR OPAQUE FINISH: ONE COAT OF WOOD PRIMER. THRESHOLDS. GRAM-NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR 2.DOORS FOR TRANSPARENT FINISH: STAIN ANDFIRST COAT OF ISSUE DATE: 11/1/17 b.CORE: 5/8 INCH (15.9 MM), TYPEX. BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTMD3273 FINISH. DESIGNER: LISA MACEDA c.MOLD RESISTANCE: ASTMD3273, SCORE OF 10 AS RATED R AND EVALUATED ACCORDING TO ASTMD3274 OR ASTMG21. B.FACTORY FINISHING: ALL DOORS. LEED AP: ACCORDING TO ASTMD3274. D.ACOUSTICAL CEILING PANELS PERFORATED: END OF SECTION 081416 PRODUCTION DESIGNER: PETER CHEETHAM 2.CEMENTITIOUS BACKER UNITS: ANSIA118.9 AND 1.CLASSIFICATION: TYPEIII, MINERAL BASE WITH PAINTED FINISH; CHECKED BY: ASTMC1288 OR 1325, WITH MANUFACTURER'S STANDARD EDGES. FORM2, WATER FELTED; PATTERN CE (PERFORATED, SMALL a.THICKNESS: 1/4 INCH (6.4 MM). HOLES AND LIGHTLY TEXTURED). b.MOLD RESISTANCE: ASTMD3273, SCORE OF 10 AS RATED Revision Schedule 2.COLOR: AS INDICATED ON DRAWINGS. ACCORDING TO ASTMD3274. 3.THICKNESS: 3/4 INCH (15 MM). C.TRIM ACCESSORIES: RevDateByDescription 4.MODULAR SIZE: 24 BY 48 INCHES (610 BY 1220 MM). a.INTERIOR: CORNERBEAD. 5.BROAD SPECTRUM ANTIMICROBIAL FUNGICIDE AND BACTERICIDE END OF SECTION 092900 TREATMENT: PROVIDE ACOUSTICAL TILES TREATED WITH MANUFACTURER'S STANDARD ANTIMICROBIAL FORMULATION THAT C:\\Users\\zach.scholl\\Documents\\Starbucks_131st INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM-POSITIVE AND GRAM-NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR BACTERIAL GROWTH WHEN TESTED ACCORDING TO ASTMD3273 AND EVALUATED ACCORDING TO ASTMD3274 OR ASTMG21. SHEET TITLE: E.METAL SUSPENSION SYSTEMS: 1.WIDE-FACE, CAPPED, DOUBLE-WEB STEEL: INTERMEDIATE DUTY. CONSTRUCTION F.METAL EDGE MOLDINGS AND TRIM: ROLL-FORMED SHEET METAL. 1.5INSTALLATION SPECIFICATIONS A.INSTALLATION: ASTMC636. NO SCALE SCALE: 1.6FIELD QUALITY CONTROL A.TESTING: BY CONTRACTOR - ENGAGED AGENCY TO TEST SHEET NUMBER: ACOUSTICAL PANEL CEILING HANGER FASTENERS. END OF SECTION 095113 G-0012 10/31/2017 6:18:24 PM FINISHES (CONTINUED)FINISHES (CONTINUED) SECTION 09930 - WOOD STAINS AND TRANSPARENT FINISHES SECTION 097200 - WALL COVERINGS 1.1SUMMARY 1.1SUMMARY A.SURFACE PREPARATION AND APPLICATION OF WOOD FINISHES ON A.VINYL AND WOVEN GLASS-FIBER WALL COVERING. \[EXTERIOR\] \[AND\] \[INTERIOR\] SUBSTRATES. 1.2MATERIALS 1.2SUBMITTALS A.ADHESIVE: MILDEW-RESISTANT, NONSTAINING,STRIPPABLE ADHESIVE, FOR A.SAMPLES FOR VERIFICATION: FOR EACH TYPE OF FINISH SYSTEM AND IN USE WITH SPECIFIC WALL COVERING AND SUBSTRATE APPLICATION, AS EACH COLOR AND GLOSS OF FINISH INDICATED. RECOMMENDED IN WRITING BY WALL-COVERING MANUFACTURER,AND WITH 1.3QUALITY ASSURANCE A VOC CONTENT OF 50 G/L OR LESS WHEN CALCULATED ACCORDING TO R A.QUALITY STANDARDS: "MPI APPROVED PRODUCTS LIST" AND "MPI 40CFR59, SUBPARTD (EPA METHOD24). ARCHITECTURAL PAINTING SPECIFICATION MANUAL." 1.3INSTALLATION C 2017 STARBUCKS COFFEE COMPANY 1.4GENERAL A.INSTALL STRIPS IN SAME ORDER AS CUT FROM ROLL. A.CHEMICAL COMPONENTS OF FIELD-APPLIED INTERIOR PAINTS AND COATINGS: END OF SECTION 097200 1.VOC LIMITS: STARBUCKS COFFEE a.CLEAR WOOD FINISHES, VARNISHES: VOC NOT MORE THAN 350 G/L. COMPANY b.SHELLACS, CLEAR: VOC NOT MORE THAN 730 G/L. SECTION 099123 - INTERIOR PAINTING c.STAINS: VOC NOT MORE THAN 250 G/L. 2401 UTAH AVENUE SOUTH 1.1SUMMARY d.PRIMERS, SEALERS, AND UNDERCOATERS: 200 G/L. SEATTLE, WASHINGTON 98134 A.SURFACE PREPARATION AND THE APPLICATION OF PAINT SYSTEMS ON e.FIRE RETARDANT COATINGS, CLEAR: 650 G/L. (206) 318-1575 INTERIOR SUBSTRATES. f.FIRE RETARDANT COATINGS, PIGMENTED: 350 G/L. 1.2SUBMITTALS 1.5EXTERIOR WOOD-FINISH-SYSTEM SCHEDULE THESE DRAWINGS AND SPECIFICATIONS ARE A.SAMPLES FOR VERIFICATION: A.SOLID-COLOR LATEX STAIN SYSTEM: MPIEXT6.3K. CONFIDENTIAL AND SHALL REMAIN THE SOLE 1.FOR EACH NON-STANDARD LATEX TOPCOAT COLOR AND GLOSS 1.PRIME COAT: PRIMER, LATEX FOR EXTERIOR WOOD. PROPERTY OF STARBUCKS CORPORATION, INDICATED. 2.INTERMEDIATE COAT: STAIN, EXTERIOR, WATER BASED, SOLID HIDE, WHICH IS THE OWNER OF THE COPYRIGHT IN 2.FOR EACH TYPE OF NON-STANDARD PAINT SYSTEM AND IN EACH MATCHING TOPCOAT. THIS WORK. THEY SHALL NOT BE COLOR AND GLOSS OF TOPCOAT INDICATED. 3.TOPCOAT: STAIN, EXTERIOR, WATER BASED, SOLID HIDE. REPRODUCED (IN WHOLE OR IN PART), SHARED 1.3QUALITY ASSURANCE B.SEMITRANSPARENT STAIN SYSTEM: MPIEXT6.3D. WITH THIRD PARTIES OR USED IN ANY MANNER A.QUALITY STANDARDS: "MPI APPROVED PRODUCTS LIST" AND "MPI 1.TWO STAIN COATS: EXTERIOR SEMITRANSPARENT LATEX STAIN. ON OTHER PROJECTS OR EXTENSIONS TO THIS ARCHITECTURAL PAINTING SPECIFICATION MANUAL." 1.6INTERIOR WOOD-FINISH-SYSTEM SCHEDULE PROJECT WITHOUT THE PRIOR WRITTEN B.MOCKUPS FOR EACH COLOR AND FINISH. A.SEMITRANSPARENT STAIN SYSTEM: CONSENT OF STARBUCKS CORPORATION. 1.4GENERAL 1.PRIME COAT: STAIN, SEMI-TRANSPARENT, MATCHING TOPCOAT. THESE DRAWINGS AND SPECIFICATIONS ARE A.VOC CONTENT: PRODUCTS SHALL COMPLY WITH VOC LIMITS OF 2.TOPCOAT: STAIN, SEMI-TRANSPARENT, FOR INTERIOR WOOD. INTENDED TO EXPRESS DESIGN INTENT FOR A AUTHORITIES HAVING JURISDICTION \[AND, FOR INTERIOR PAINTS AND B.WATER-BASED VARNISH SYSTEM: PROTOTYPICAL STARBUCKS STORE (WHICH IS COATINGS APPLIED AT PROJECT SITE, THE FOLLOWING VOC LIMITS, a.PRIME COAT: WATER-BASED VARNISH MATCHING TOPCOAT. SUBJECT TO CHANGE AT ANYTIME) AND DO EXCLUSIVE OF COLORANTS ADDED TO A TINT BASE, WHEN CALCULATED b.INTERMEDIATE COAT: WATER-BASED VARNISH MATCHING TOPCOAT. NOT REFLECT ACTUAL SITE CONDITIONS. ACCORDING TO 40CFR59, SUBPARTD (EPA METHOD24)\]. c.TOPCOAT: VARNISH, WATER BASED, CLEAR. NEITHER PARTY SHALL HAVE ANY OBLIGATION 1.FLAT PAINTS AND COATINGS: 50 G/L. C.WATER-BASED FIRE RETARDANT SYSTEM: NOR LIABILITY TO THE OTHER (EXCEPT STATED 2.NONFLAT PAINTS AND COATINGS: 150 G/L. a.TOPCOAT: FIRE RETARDANT COATING, CLEAR. ABOVE) UNTIL A WRITTEN AGREEMENT IS 3.DRY-FOG COATINGS: 400 G/L. 1.CLASS A FLAME SPREAD AND SMOKE-DEVELOPED INDEX PER FULLYEXECUTEDBYBOTHPARTIES 4.PRIMERS, SEALERS, AND UNDERCOATERS: 200 G/L. ASTM E 84. 5.ANTICORROSIVE AND ANTIRUST PAINTS APPLIED TO FERROUS END OF SECTION 09930 METALS: 250 G/L.STARBUCKS TEMPLATE VERSION i2017.08.25 6.ZINC-RICH INDUSTRIAL MAINTENANCE PRIMERS: 340 G/L. 7.PRETREATMENT WASH PRIMERS: 420 G/L. 8.FLOOR COATINGS: 100 G/L. Design Forum 9.SHELLACS, CLEAR: 730 G/L. 10.SHELLACS, PIGMENTED: 550 G/L. 1.5INTERIOR PAINTING SCHEDULE Architects Inc. A.STEEL SUBSTRATES: 700 W. Pete Rose Way, Suite 460Donald J. Rethman 1.INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: Cincinnati, OH 45203Architect In Charge a.PRIME COAT: PRIMER, RUST-INHIBITIVE, WATER BASED. Tel: (513) 421-2210License: AR19700147 b.TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR LATEX (GLOSSLEVEL AS INDICATED IN PAINT SCHEDULE). B.GALVANIZED-METAL SUBSTRATES: Design Forum 1.INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: a.PRIME COAT: PRIMER, GALVANIZED, WATER BASED. b.TOPCOAT: LATEX, INTERIOR, INSTITUTIONAL LOW Engineering ODOR/VOC, (GLOSS LEVEL AS INDICATED IN PAINT 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE SCHEDULE). Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 C.WOOD SUBSTRATES: 1.INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: a.PRIME COAT: INTERIOR LATEX PRIMER/SEALER. b.TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). D.GYPSUM BOARD SUBSTRATES: 1.INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: a.PRIME COAT: INTERIOR LATEX PRIMER/SEALER. b.TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). E.HIGH-IMPACT GYPSUM BOARD SUBSTRATES: 1.HIGH-PERFORMANCE ARCHITECTURAL LATEX SYSTEM: a.PRIME COAT: INTERIOR LATEX PRIMER/SEALER. 11/01/17 09/01/17 b.TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). F.PLASTER SUBSTRATES: 1.INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: a.PRIME COAT: INTERIOR LATEX PRIMER/SEALER. b.TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR L LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). L G.ACOUSTICAL CEILING TILE: Y E 1.INSTITUTIONAL LOW-ODOR/VOC LATEX SYSTEM: W a.PRIME COAT: INTERIOR LATEX PRIMER/SEALER. D b.TOPCOAT: INSTITUTIONAL LOW-ODOR/VOC INTERIOR K LATEX (GLOSS LEVEL AS INDICATED IN PAINT SCHEDULE). P L END OF SECTION 099123 L E 3 L 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: CONSTRUCTION SPECIFICATIONS NO SCALE SCALE: SHEET NUMBER: G-0013 10/31/2017 6:18:27 PM SHEET NOTES 1.EXISTING CIRCULAR BOLLARD TO REMAIN. 2.EXISTING TRASH ENCLOSURE WITH CONCRETE PAD TO REMAIN. 3.EXISTING LANDSCAPING TO REMAIN. 4.EXISTING ADA RAMP TO REMAIN. 5.EXISTING SIDEWALK TO REMAIN. 6.EXISTING OUTDOOR FURNITURE AND UMBRELLAS TO BE R DEMOLISHED. COORDINATE WITH STARBUCKS CM FOR DISPOSAL OF FURNITURE FROM SITE. C 2017 STARBUCKS COFFEE COMPANY 7.EXISTING PATIO RAILING TO REMAIN. STARBUCKS COFFEE 8.EXISTING LIGHT POLE TO REMAIN. COMPANY 9.EXISTING STRIPING TO REMAIN. 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 10.EXISTING ADA PARKING AND ADA PARKING SYMBOL TO REMAIN. (206) 318-1575 11.EXISTING TRANSFORMER WITH CONCRETE PAD TO REMAIN. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE EXISTING FIRE HYDRANT TO REMAIN. 12. PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN 13.EXISTING ELECTRICAL UTILITY TO REMAIN. THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED 14. EXISTING "STOP" SIGN TO REMAIN. WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS 15.EXISTING "STOP" BAR TO REMAIN. PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. 16.EXISTING "SPEED LIMIT" SIGN TO REMAIN. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A EXISTING SPEAKER POST TO BE DEMOLISHED. 17. PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 18.EXISTING CROSSWALK STRIPING TO REMAIN. NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION 19. EXISTING CANOPY ABOVE TO REMAIN. NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS 20.LEASE LINE. 3 FULLYEXECUTEDBYBOTHPARTIES 88 21.REPAINT EXISTING STRIPING. (COLOR : WHITE). STARBUCKS TEMPLATE VERSION i2017.08.25 5 EXISTING DRIVE-THRU SHELF TO BE DEMOLISHED. 22. 23.EXISTING THANK YOU/EXIT ONLY SIGNAGE TO BE DEMOLISHED, Design Forum FOOTING TO REMAIN. 3 EXISTING 24.EXISTING 5-PANEL MENU BOARD TO BE DEMOLISHED, FOOTING TO PARKING Architects Inc. REMAIN. 4 700 W. Pete Rose Way, Suite 460Donald J. Rethman 5 Cincinnati, OH 45203Architect In Charge 25.EXISTING PRE-MENU BOARD TO BE DEMOLISHED, FOOTING TO Tel: (513) 421-2210License: AR19700147 3 REMAIN. 5 26.EXISTING CLEARANCE BAR TO BE DEMOLISHED, FOOTING TO Design Forum REMAIN. V.I.F 23' - 0" Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 3 Tel: (513) 421-2210 43 5 3 3 10 SITE DEMOLITION LEGEND MATERIALS TO BE DEMOLISHED 5 ADJACENT TENANT 49 8 20 26 2 10 3 11/01/1709/01/17 5 12' - 10" 27' - 3" 3 25 V.I.F V.I.F 20 5 L 83 L 20 Y E STARBUCKS COFFEE W 17 2822 SF D K 19 P 6 L 24 L E 3 PATIO L 3 Z 56 E 0 A D6 5 4 L H 3 5 E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & DRIVE , 21 (E) DRIVE THRU A 7 L F THRU LANE 2011 . I TIMER LOOP . T H E V 1 4 SENSOR 12' - 0" 321 S 0 M 7 1 R 1 22 8 3 A 3 4 1 1C 16 23 STORE #:8123 (E) DRIVE THRU 15 131211 8 TIMER LOOP PROJECT #:25450-048 SENSOR 5 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA 33 R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: 18 4 44 5 5 4 Revision Schedule 3 RevDateByDescription 3 14 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 15 SHEET TITLE: DEMOLITION SITE PLAN 1/16" = 1'-0" SCALE: 08'16'32' SHEET NUMBER: N Scale: 1/16" = 1'-0" DEMOLITION SITE PLAN A-1000 1 10/31/2017 6:15:35 PM Scale: 1/16" = 1'-0" SITE SCHEDULE - "Y"EXTERIOR SIGNAGE SCHEDULE - "S" ARCHITECTURAL SITE PLAN NOTES SIGNAGE IS FOR REFERENCE ONLY A.REFER TO EXTERIOR ELEVATIONS FOR BUILDING SIGNAGE DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS SIGNAGE APPROVALS SHALL BE ACQUIRED UNDER SEPARATE LOCATION AND DESIGN ID. REFER TO ELECTRICAL PLANS FOR EXTERIOR MENUSIGNAGE - DRIVE THRU SIGN PERMIT SUBMITTALS. SIGNAGE IS NOT INCLUDED IN THE ELECTRICAL REQUIREMENTS. 140301MENU BOARD - DT DIGITAL ORDER SCREENSB-SBREFER DETAIL: 6/A-1003140911SIGN - DT DIRECTIONAL EXIT SIGNSB-SBEXISTING FOOTING & CONDUIT, SIGN SCOPE OF THE BUILDING PERMIT. POST - FLAT BLACK MT0028ILLUMINATED ARROW SERIES - 46IN 1170MM(SB); SEE DETAIL:4/A-1004 DRIVE-THRU EQUIPMENT INCLUDING VEHICLE DETECTION B. 141161MENU BOARD - DT DIGITAL ORDER SCREEN -SB-SBREFER DETAIL: 6/A-1003; FOOTING141061SIGN - DT CLEARANCE BAR ARROW SERIESSB-SBEXISTING FOOTING & CONDUIT, SIGN LOOP, WIRELESS COMMUNICATION, AND MONITORS FLAT BLACK MT0028AND CONDUIT BY GCFREESTANDING(SB); SEE DETAIL: 2/A-1004 COORDINATED BY STARBUCKS CONSTRUCTION MANAGER. 141191MENU BOARD - DT 5 PANEL FREESTANDING -SB-SBREFER DETAIL: 1/A-1003 REFER TO ELECTRICAL SPECIFICATIONS FOR ELECTRICAL RESPONSIBILITY LEGEND 108X65IN 2745X1650MM - FLAT BLACK MT0028 REQUIREMENTS. 141201MENU BOARD - DT PRE MENUSB-SBREFER DETAIL: 3/A-1003 SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR C.GC IS RESPONSIBLE FOR PROVIDING SITE WORK, INCLUDING FREESTANDING - 36X65IN 915X1650MM - FLAT R NEW BOLLARDS, FOOTING AND CONDUIT FOR DRIVE-THRU BLACK MT0028 SB-SB FURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS SIGNAGE. COORDINATE WITH STARBUCKS CONSTRUCTION C 2017 STARBUCKS COFFEE COMPANY 157001MENU BOARD - DT DIGITAL ORDER SCREENSB-SBREFER DETAIL: 8/A-1003 MANAGER. CONTROL BOX GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY GENERAL CONTRACTOR OTHER D.GC TO RE-SEAL AND RE-STRIPE ALL PARKING AND DRIVE-THRU. STARBUCKS COFFEE 100201DT WINDOW SHELF - 48IN 1205MM - SSTSB-GCSEE DETAIL: 4/A-1003 ; READY NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS ACCESS - MODEL 275 SHELF COMPANY E.EXISTING TRASH ENCLOSURE TO REMAIN. DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION 100421BIKE RACK HOOPSB-GCREFER DETAIL: 9/A-1004 2401 UTAH AVENUE SOUTH F.EXISTING 6" (150MM) THICK CONCRETE PAVING TO REMAIN. 140931DT WAYFINDING GRAPHIC ORDER POINTGC-GCSEE DETAIL: 11/A-1004; ENNIS FLINT - SEATTLE, WASHINGTON 98134 STAR PATTERN - WHITESTARBUCKS DRIVE THROUGH, G.GENERAL CONTRACTOR TO APPLY CONCRETE SEALER TO ALL DESIGN # 14-110; 336.475.6600 (206) 318-1575 EXTERIOR CONCRETE PATIO AND WALKWAY SURFACES. 140951DT WAYFINDING GRAPHIC EXIT ARROW -GC-GCSEE DETAIL:7/A-1004; ENNIS FLINT - THESE DRAWINGS AND SPECIFICATIONS ARE WHITESTARBUCKS DRIVE THROUGH CONFIDENTIAL AND SHALL REMAIN THE SOLE DIRECTIONAL ARROWS; DESIGN # PROPERTY OF STARBUCKS CORPORATION, 14-020-03 WHICH IS THE OWNER OF THE COPYRIGHT IN 141011DT WAYFINDING GRAPHIC ENTRY ARROW -GC-GCREFER DETAIL: 6/A-1004; ENNIS FLINT SHEET NOTES THIS WORK. THEY SHALL NOT BE GREEN- STARBUCKS DRIVE THROUGH REPRODUCED (IN WHOLE OR IN PART), SHARED 1.ALL NEW SITE WORK BY GC. DIRECTIONAL ARROWS; DESIGN # WITH THIRD PARTIES OR USED IN ANY MANNER 14-020-03 ON OTHER PROJECTS OR EXTENSIONS TO THIS 2.DRIVE-THRU EXIT ARROW BY GC. 141031BOLLARD NONILLUMINATED SQUARE - FLATGC-GCREFER DETAIL: 1/A-1004 PROJECT WITHOUT THE PRIOR WRITTEN BLACK MT0028 CONSENT OF STARBUCKS CORPORATION. 3.DRIVE-THRU ENTRY ARROW BY GC. 143234DT WAYFINDING GRAPHIC DIRECTIONALGC-GCREFERENCE PAINT P936 FOR THESE DRAWINGS AND SPECIFICATIONS ARE DOUBLE ARROW - GREENSPECIFICATIONS; REFER DETAIL: INTENDED TO EXPRESS DESIGN INTENT FOR A 4.REPAINT EXISTING STRIPING. (COLOR : WHITE). 8/A-1004 PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 143244DT WAYFINDING GRAPHIC DIRECTIONALGC-GCREFERENCE PAINT P935 FOR 5. GC TO INSTALL NEW DRIVE-THRU SHELF, SEE DETAIL 5/A-1003. DOUBLE ARROW - WHITESPECIFICATIONS; REFER DETAIL:NOT REFLECT ACTUAL SITE CONDITIONS. 8/A-1004 NEITHER PARTY SHALL HAVE ANY OBLIGATION 6.NON ILLUMINATED SQUARE BOLLARD BY GC. NOR LIABILITY TO THE OTHER (EXCEPT STATED UMBRELLA ABOVE) UNTIL A WRITTEN AGREEMENT IS 7. REPLACE EXISTING CLEARANCE BAR WITH NEW. REUSE EXISTING 121473UMBRELLA - BASE FOR CANOPY - BLACKSB-GC FULLYEXECUTEDBYBOTHPARTIES FOOTING. MT0028 166283UMBRELLA - WITHOUT VALANCE - 6FT 183CMSB-GC 8."DO NOT ENTER" PAVEMENT TEXT BY GC. (COLOR : WHITE). STARBUCKS TEMPLATE VERSION i2017.08.25 - GREY CANVAS F0177 9.INSTALL NEW DIGITAL ORDER SCREEN. GC TO RE-ROUTE EXISTING CONDUIT TO NEW LOCATION. CONCRETE FOOTING BY GC. Design Forum 10.REPLACE EXISTING 5-PANEL MENU BOARD WITH NEW. REUSE EXISTING FOOTING AND CONDUIT. Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 11.REPLACE EXISTING PRE-MENU BOARD WITH NEW. REUSE EXISTING Cincinnati, OH 45203Architect In Charge FOOTING AND CONDUIT. Tel: (513) 421-2210License: AR19700147 12.EXIT PAVEMENT DOUBLE ARROW-WHITE BY GC, SEE DETAIL 8/A-1004. EXISTING Design Forum PARKING 13. ENTER PAVEMENT DOUBLE ARROW-GREEN BY GC, SEE DETAIL 8/A-1004. Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 14.WHEEL STOP BY GC. Cincinnati, OH 45203Professional Engineer EQEQ License: PE10504904 Tel: (513) 421-2210 14323 YY14323 1313 15."STOP" BAR BY GC. (COLOR : WHITE). 16. INSTALL NEW PATIO FURNITURE. REFER TO FF&E PLAN. 7' - 0"7' - 0" Y14324 14324 Y 1212 17.LEASE LINE Y14101 3 EQEQ 6 18.BIKE RACK BY GC, SEE DETAIL 9/A-1004. A-1004 19.REPLACE EXISTING DRIVE-THRU 'EXIT ONLY' SIGN WITH NEW. REUSE EXISTING FOOTING. EQEQ 11/01/17 09/01/17 Y1432412 ADJACENT TENANT 13 Y14323 27' - 11" 17 L 7S14106 14 8 L A-1004 TYP. Y 57' - 11" E 12' - 10" W 14120 Y D EQ7' - 0"EQ V.I.F K 6' - 0" V.I.F 11 P L 17 Y14103 6 L 14116 Y E V.I.F 3 9' - 1" A-2001 3 L 3 14030 Y Z E 0 STARBUCKS COFFEE Y15700 18 Y10042 A D6 4' - 6" 2822 SF 9 4 45' - 0" L H 9 1 6 E N 9' - 0" A-1004 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , PATIO Y14093 17 A L 16 T H E EQ7' - 0"EQ A-2001 2 Y14119 S 0 V.I.F M 14' - 8" 10 7 1 R 5 1 3 A 3 DRIVE - 1 1C 4 EQ (3) Y16628 17 THRU LANE 1 Y1432313 (3) 8 12147 Y V.I.F 4 STORE #:8123 12' - 0" 321 A-1002 EQ 15 PROJECT #:25450-048 14095 Y 2 1432412 Y Y10020 ISSUE DATE: 11/1/17 2 1' - 0" DESIGNER: 5 LISA MACEDA A-1002 R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 5' - 3" CHECKED BY: S14091 1 V.I.F 19 Revision Schedule A-2001 RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: ARCHITECTURAL SITE PLAN 1/16" = 1'-0" SCALE: 08'16'32' SHEET NUMBER: ARCHITECTURAL SITE PLAN Scale: 1/16" = 1'-0" 1 N Scale: 1/16" = 1'-0" A-1001 10/31/2017 6:15:44 PM CONCRETE FOOTING BY GC. SEE DETAIL 1/A-1004 SIGNAGE IS FOR REFERENCE ONLY EXISTING NON ILLUMINATED SIGNAGE APPROVALS SHALL BE TRASH BOLLARD ACQUIRED UNDER SEPARATE SIGN ENCLOSURE PERMIT SUBMITTALS. SIGNAGE IS NOT INCLUDED IN THE SCOPE OF A-1004 THE BUILDING PERMIT 2 1' - 6" R EXISTING CONCRETE C 2017 STARBUCKS COFFEE COMPANY 1' - 0" Y14106 FOOTING CLEARANCE V.I.F BAR STARBUCKS COFFEE V.I.F COMPANY 6' - 0" 3' - 0" 2401 UTAH AVENUE SOUTH A-1003 V.I.F SEATTLE, WASHINGTON 98134 3 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE OUTLINE OF CONFIDENTIAL AND SHALL REMAIN THE SOLE MENU BOARD ° PROPERTY OF STARBUCKS CORPORATION, 0 SIGNAGE IS FOR REFERENCE ONLY 3 WHICH IS THE OWNER OF THE COPYRIGHT IN EXISTING CONCRETE THIS WORK. THEY SHALL NOT BE FOOTING SIGNAGE APPROVALS SHALL BE REPRODUCED (IN WHOLE OR IN PART), SHARED ACQUIRED UNDER SEPARATE SIGN WITH THIRD PARTIES OR USED IN ANY MANNER EXISTING PERMIT SUBMITTALS. SIGNAGE IS Y14120 ON OTHER PROJECTS OR EXTENSIONS TO THIS CURB NOT INCLUDED IN THE SCOPE OF PROJECT WITHOUT THE PRIOR WRITTEN THE BUILDING PERMIT CONSENT OF STARBUCKS CORPORATION. (E) CONDUIT THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A EXISTING STARBUCKS PROTOTYPICAL STARBUCKS STORE (WHICH IS LANDSCAPING V.I.F 9' - 1" SUBJECT TO CHANGE AT ANYTIME) AND DO COFFEE 12' - 10" EXISTING PATIO PATIO NOT REFLECT ACTUAL SITE CONDITIONS. RAILING NEITHER PARTY SHALL HAVE ANY OBLIGATION V.I.F NOR LIABILITY TO THE OTHER (EXCEPT STATED EXISTING EXISTING CONCRETE FOOTING BY ABOVE) UNTIL A WRITTEN AGREEMENT IS LIGHT POLE CURBGC. SEE DETAIL 1/A-1004 FULLYEXECUTEDBYBOTHPARTIES Y14103 OUTLINE OF DIGITAL A-1004 1STARBUCKS TEMPLATE VERSION i2017.08.25 5' - 3" 1' - 0" NON ILLUMINATED CONCRETE FOOTING BY ORDER SCREEN BOLLARDGC. SEE SHEET 10/A-1003 V.I.F EXISTING EXISTING REROUTE CONDUIT CURB CURB TO CONTROL BOX Design Forum 1' - 0" OUTLINE OF DIGITAL ORDER 11 SCREEN CONTROL BOX ON (E) DETECTOR LOOP A-1004 CONCRETE FOOTING Architects Inc. EQ 2' - 0" EXISTING 700 W. Pete Rose Way, Suite 460Donald J. Rethman LANDSCAPING Cincinnati, OH 45203Architect In Charge 4' - 6" 7 Tel: (513) 421-2210License: AR19700147 A-1004 3'-0"X3'-0" MIN. CLEAR AREA FOR CONTROL BOX 14093 Y Design Forum (3) CONDUIT FROM CONTROL THERMO BOX, ROUTE TO DRIVE - THRU PLASTIC BY GC A-1003 7 WINDOW (1) CONDUIT FROM DRIVE-THRU Engineering CONTROL BOX, ROUTE TO LANE 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE REPAINT ELECTRICAL PANEL BY GC. Cincinnati, OH 45203Professional Engineer (E) DRIVE THRU EXISTING License: PE10504904 Tel: (513) 421-2210 TIMER LOOP STRIPING. Y14116 SENSOR (COLOR : WHITE). A-1003 8 Y14030 EQEQ EQ 15700 Y (E) CONDUIT TO PANEL 14095 Y 2' - 2"8' - 6"2' - 2"5' - 9" "DO NOT ENTER" PAVEMENT TEXT BY THERMO V.I.F 9' - 0" GC. (COLOR : WHITE). PLASTIC BY GC REA EXISTING EXISTING CURB LANDSCAPING 15' - 3" . CLR. A "STOP" BAR BY GC. 11/01/17 09/01/17 (COLOR : WHITE). A-1004 MIN A-1003 1A S14091 DT SIGN 4C EXISTING EXISTING DRIVE - BY SB CURB CURB L THRU LANE EXISTING L OUTLINE OF ° Y CURB 0 MENU BOARD E 1 VERIFY EXISTING EXISTING W EXISTING CONCRETE D CONDUIT IS STUBBED UP ADA RAMP FOOTING K IN CENTER OF FOOTING P L Y14119 L 4AA-1004 4 E 3 " L 0 A-1004 -4B 3 ' R 1 Z L E C 0 EXISTING N I M A D6 LANDSCAPING EXISTING CONCRETE EXISTING 4 3' - 3" L H FOOTING TO REMAIN. GC LANDSCAPING EXISTING E N 3'-0" MIN CLRTO VERIFY SUITABILITY SIDEWALK I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z FOR USE WITH NEW & , SIGNAGE A L 5-PANEL MENU BOARD, DIGITAL ORDER SCREEN, PRE-MENU BOARD AND T H E S 0 M CLEARANCE BAR LOCATION ILLUMINATED DIRECTIONAL SIGNAGE LOCATION - EXIT 7 1 12 R Scale: 3/8" = 1'-0"Scale: 3/8" = 1'-0" 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: ENLARGED EXTERIOR PLAN 3/8" = 1'-0" SCALE: SHEET NUMBER: A-1002 10/31/2017 6:15:48 PM THIS DETAIL IS FOR REFERENCE ONLY. SIGNAGE 6' - 10" SUPPLIED AND INSTALLED BY OTHERS UNDER SEPARATE PERMIT. HOLD THIS DETAIL IS FOR REFERENCE ONLY. SIGNAGE SUPPLIED AND INSTALLED BY OTHERS UNDER 3' - 0" SEPARATE PERMIT. 3' - 0" EXISTING CONCRETE FOOTING A-1003 V.I.F OUTLINE OF 3 4 9' - 0" MENU BOARD A-1003 DRIVE-THRU D LANE Y14120 R HOL 6' - 11" C 2017 STARBUCKS COFFEE COMPANY ° 4' - 0" 0 EXISTING 3 CURB 5' - 5" STARBUCKS COFFEE (1) CONDUIT, COMPANY 4' - 0" ROUTE BACK CORIAN SOLID TO ELECTRICAL SURFACE TO 2401 UTAH AVENUE SOUTH PANEL BY GC. MATCH COUNTERS 5' - 5" SEATTLE, WASHINGTON 98134 EXISTING 10" BY SB FINISH LANDSCAPING (206) 318-1575 GRADE 1' - 5" THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE 2' - 2" PROPERTY OF STARBUCKS CORPORATION, FINISH GRADE WHICH IS THE OWNER OF THE COPYRIGHT IN 1' - 5" THIS WORK. THEY SHALL NOT BE ELEVATIONPLAN REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER 3' - 1" ON OTHER PROJECTS OR EXTENSIONS TO THIS EXISTING BOLLARD ELEVATION - B DTE-PRE MENU FREESTANDING PROJECT WITHOUT THE PRIOR WRITTEN EXISTING 3 CONSENT OF STARBUCKS CORPORATION. BOLLARD EXISTING CURB Scale: 1/2" = 1'-0" 2 THESE DRAWINGS AND SPECIFICATIONS ARE 2' - 11" INTENDED TO EXPRESS DESIGN INTENT FOR A DT WINDOW PER PLAN, BY GC CONCRETE FOOTING BY PROTOTYPICAL STARBUCKS STORE (WHICH IS STAINLESS STEEL A-1003 GC. SEE SHEET 10/A-1003 SUBJECT TO CHANGE AT ANYTIME) AND DO DRIVE-THRU SHELF BY GC NOT REFLECT ACTUAL SITE CONDITIONS. OUTLINE OF DIGITAL ORDER NEITHER PARTY SHALL HAVE ANY OBLIGATION (E) DETECTOR LOOP Y14116 SCREEN CONTROL BOX ON NOR LIABILITY TO THE OTHER (EXCEPT STATED SIGN WITH BASE Y14030 CONCRETE FOOTING 2' - 0" ABOVE) UNTIL A WRITTEN AGREEMENT IS AND PLATE COVER 15700 Y SIGNAGE IS FOR REFERENCE ONLY (BY STARBUCKS)FULLYEXECUTEDBYBOTHPARTIES OUTLINE OF DIGITAL 3'-0"X3'-0" MIN. CLEAR ORDER SCREEN AREA FOR CONTROL BOX SIGNAGE APPROVALS SHALL BE STARBUCKS TEMPLATE VERSION i2017.08.25 ACQUIRED UNDER SEPARATE SIGN REROUTE CONDUIT 4' - 5" (3) CONDUIT FROM CONTROL PERMIT SUBMITTALS. SIGNAGE IS TO CONTROL BOX BOX, ROUTE TO DRIVE-THRU NOT INCLUDED IN THE SCOPE OF RELOCATE EXISTING WINDOW (1) CONDUIT FROM THE BUILDING PERMIT Design Forum 4 STRUCTURAL LINTEL CONTROL BOX, ROUTE TO A-1003 TO NEW HEIGHT AS 4' - 0"ELECTRICAL PANEL BY GC. REQUIRED TO Architects Inc. ACCOMMODATE AIR- 5' - 9" 700 W. Pete Rose Way, Suite 460Donald J. Rethman CURTAIN Cincinnati, OH 45203Architect In Charge V.I.F Tel: (513) 421-2210License: AR19700147 FINISH GRADE A-1003 8 EXISTING 1' - 4" 4" LANDSCAPING (E) CONDUIT TO PANEL M10894 Design Forum 2' - 2" READY ACCESS DRIVE-THRU AIR 300 AIR- LANE CONCRETE FOOTING (E) DETECTOR LOOP CURTAIN BY GC Engineering OUTLINE OF EXISTING SEE DETAIL 10/A-1003 MENU BOARD 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE CURB A-1003 Cincinnati, OH 45203Professional Engineer 14077 W 1A License: PE10504904 Tel: (513) 421-2210 5' - 0" READY ACCESS DT WINDOW PER PLAN BY GC CLEARANCE AREA Y10020 ° DIGITAL ORDER SCREEN LOCATIONDIGITAL ORDER SCREEN 0 1 DT SHELF BY GC 67 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" DRIVE-THRU EXISTING CONCRETE FOOTING LANE ALL CONDUIT BY LL (1) CONDUIT, ROUTE TO ELECTRICAL PANEL (2) CONDUIT, ROUTE TO BUMP-OUT POINT OF SALE Y14119 (1) CONDUIT, ROUTE TO DETECTOR LOOP AT DOS 11/01/1709/01/17 3' - 0" PROVIDE NEW MOUNTED ON UNISTRUT ON DOS SUPPORT FOR FOOTING. LINTELS TO MATCH " 0 EXISTING - DIGITAL ORDER SCREEN CONTROL ' R 1 L C BOX ON UNISTRUT POSTS N I L M 6" L Y EXISTING EXISTING BOLLARD 3' - 3" E PLAN - A BOLLARD EXTERIOR INTERIOR W 3'-0" MIN CLR D FINISH GRADEFINISH GRADE3'-0" x 3'-0" CLEAR K ELEVATION AREA AT BOX DOOR P L L E 3 L 3 Z E 0 5-PANEL MENU BOARD PLANENLARGED DRIVE-THRU BUMP-OUT ELEVATIONDTE - DOS CONTROL BOX FREESTANDING A D6 129 Scale:Scale:Scale: 1/2" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-0" 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , FREESTANDING ORDER SCREEN A L (DESIGN VARIES) T H E S 0 M DOS POST; ATTACH SHELF TO BUILDING 7 1 CLAMP UNISTRUT TO POST R 3/4" DIA x 24" L ANCHOR BOLTS EXTERIOR FLUSH TO TOP OF 1 AND BOLT DCB TO 3 A (F1554 GRADE 36 - 4 EA.) 3 ROUGH OPENING, SHELF TO UNISTRUT 1 1C BE STAINLESS STEEL FINISHED GRADE 3" READY ACCESS AIR 300 4' - 0" MAINTAIN EXISTING EXTERIOR AIR-CURTAIN BY GC STORE #:8123 SILL CONDITION PROJECT #:25450-048 DIGITAL ORDER SCREEN DRIVE-THRU WINDOW 5 BEYONDPROPOSED BELOW GRADE ISSUE DATE: 11/1/17 1/4" SEALANT JOINT 10" (READY ACCESS) BY GC EQ. A-1003 CONCRETE FOUNDATION. DESIGNER: LISA MACEDA R SOLID SURFACE CP0002 LEED AP: CONDUIT WITH 10" UIT ATTACH SHELF TO W/1/4" EASED EDGE PRODUCTION DESIGNER: PETER CHEETHAM WATERTIGHT COUPLING BUILDING EXTERIOR 2" CHECKED BY: CX1013PER ELECTRICAL EQ FLUSH TO TOP OF ROUGH 10" 1/2" OPENING PLAN X COND 4' - 0" 8" Revision Schedule 1' - 6" MAX. 2' - 0" 6' - 0" FLE DOS BASE RevDateByDescription STAINLESS STEEL SHROUD EXISTING EQ 2" "L" CHANNEL # 3 REBAR BOTH WALL SYSTEM GRADE . WAYS AS SHOWN. 1/2" BOLT 6" C:\\Users\\zach.scholl\\Documents\\Starbucks_131st MIN 8" +/- 2" 3' - 0" STAINLESS STEEL EXISTING EQ 3' - 6" SHELF BY GC BOLLARD 3' - 10 1/2" POST FOOTING BEYOND 1/2"1/2" 1/2" SHEET TITLE: 1" EQ.EQ.EQ.2" 2 1/4" 6"1" DRIVE THRU DETAILS 12" (300MM) MINIMUM 14" (350MM) MINIMUM ELEVATIONSECTION 2' - 7 3/4" SIDE ELEVATIONFRONT ELEVATION AS SHOWN SCALE: DIGITAL ORDER SCREEN SHEET NUMBER: FOOTING (BY GC) DRIVE-THRU WINDOW SECTIONDRIVE-THRU SHELF DETAILS (BY GC)DTE - DOS CONTROL BOX ON DOS POST 45810 A-1003 Scale: 1/2" = 1'-0"Scale: 1" = 1'-0"Scale: 1" = 1'-0"Scale: 1/2" = 1'-0" 10/31/2017 6:15:55 PM 9' - 0" 3' - 6"5' - 6" R PRE SPACED VINYL LETTERING APPLIED ON SITE C 2017 STARBUCKS COFFEE COMPANY AS NEEDED SIGNAGE IS FOR REFERENCE ONLY STARBUCKS COFFEE 5" 5"X5"X1/4" (6MM) SQUARE 3" X 4" CROSS BAR SIGNAGE APPROVALS SHALL BE ACQUIRED UNDER STEEL POST COMPANY SEPARATE SIGN PERMIT SUBMITTALS. SIGNAGE IS NOT INCLUDED IN THE SCOPE OF THE BUILDING PERMIT 2401 UTAH AVENUE SOUTH SIGN WITH BASE AND PLATE WELDED STEEL REMOVABLE CAP W/ SEATTLE, WASHINGTON 98134 5" COVER (BY STARBUCKS) POWDER-COATED S-S FASTENERS DRIVEDRIVE (206) 318-1575 THRUTHRU THESE DRAWINGS AND SPECIFICATIONS ARE 11'-0" POLE HEIGHT CAP 1 1/4" THIS DETAIL IS FOR REFERENCE CONFIDENTIAL AND SHALL REMAIN THE SOLE THIS DETAIL IS FOR REFERENCE ONLY.FRONTBACK ONLY. SIGNAGE SUPPLIED AND PROPERTY OF STARBUCKS CORPORATION, SIGNAGE SUPPLIED AND INSTALLED BY INSTALLED BY OTHERS UNDER THIS DETAIL IS FOR REFERENCE ONLY. 1"ACRYLIC GRAPHIC PANELSWHICH IS THE OWNER OF THE COPYRIGHT IN OTHERS UNDER SEPARATE PERMIT. TAPE SEPARATE PERMIT.SIGNAGE SUPPLIED AND INSTALLED BY THIS WORK. THEY SHALL NOT BE SEE SHEET A-101 FOR ORIENTATION OTHERS UNDER SEPARATE PERMIT. REPRODUCED (IN WHOLE OR IN PART), SHARED OF GRAPHIC PANELS TO SITE 1" WITH THIRD PARTIES OR USED IN ANY MANNER TAPE 8' - 9" VIF PRIOR TO FABRICATION 2' - 1" 5" ON OTHER PROJECTS OR EXTENSIONS TO THIS TWO BANDS OF 1" WIDE 1' - 0" PROJECT WITHOUT THE PRIOR WRITTEN ENG. GRADE SILVER/WHITE CONSENT OF STARBUCKS CORPORATION. REFLECTIVE TAPE 2'-10" THESE DRAWINGS AND SPECIFICATIONS ARE COLOR : RAL7021BLACK 6" LOGOINTENDED TO EXPRESS DESIGN INTENT FOR A EXISTING 1' - 3"1' - 3" GREY, 10% SHEEN, EXT PROTOTYPICAL STARBUCKS STORE (WHICH IS CURB SUBJECT TO CHANGE AT ANYTIME) AND DO NON ILLUMINATED ROAD BED NOT REFLECT ACTUAL SITE CONDITIONS. SIGN WITH BASE SIGN WITH BASE SQUARE BOLLARD BY GC.SIGN WITH BASE 4' - 10" NEITHER PARTY SHALL HAVE ANY OBLIGATION AND PLATE COVER AND PLATE AND PLATE COVER NOR LIABILITY TO THE OTHER (EXCEPT STATED (BY STARBUCKS) 3' - 10"3' - 10" COVER (BY STARBUCKS) ABOVE) UNTIL A WRITTEN AGREEMENT IS (BY STARBUCKS) 2' - 3"2' - 3" FINISH GRADE 3"FULLYEXECUTEDBYBOTHPARTIES FINISHED GRADE FINISH GRADE FINISHED GRADE FINISHED EXISTING STARBUCKS TEMPLATE VERSION i2017.08.25 GRADE CONCRETE FOOTING TO 4"4" 2'-0" FOOTING BY GC. REMAIN 7" 1' - 6" Design Forum EMBED BY FIELD SIDE ELEVATION FRONT ELEVATION SIDE ELEVATION CUSTOMER ELEVATION BACKSIDE ELEVATION A B C B A Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 NON ILLUMINATED SQUARE BOLLARD (BY GC)CLEARANCE BARILLUMINATED DIRECTIONAL SIGN DRIVE-THRU ENTRYILLUMINATED DIRECTIONAL SIGN - DRIVE-THRU - EXIT ONLY 1234 Design Forum Scale:Scale:Scale:Scale: 3/4" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-0" 3'-0" Engineering THIS DETAIL IS FOR REFERENCE ONLY. 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 14095 Y 1' - 6"1' - 6" Y14101 Cincinnati, OH 45203Professional Engineer SIGNAGE SUPPLIED AND INSTALLED BY License: PE10504904 Tel: (513) 421-2210 THERMO THERMO OTHERS UNDER SEPARATE PERMIT. PLASTIC BY GC PLASTIC BY GC COLOR: P936 ° COLOR: P935 2 4 3" 3" 1' - 4"1' - 4" DIRECTIONAL SIGN 4 2 14323 Y ° PAINTED GRAPHIC WITH STENCIL ON SITE 2' - 3" 1' - 4"1' - 4" 2' - 0" COLOR:GREEN DIRECTION 3/4" DIA X 12" L PLATE OUTLINE ANCHOR BOLTS 5' - 4"5' - 4" Y14324 EMBED 6" MIN. 5' - 0" 4' - 6" 11/01/17 09/01/17 4 (2 EA.) 2 PAINTED GRAPHIC WITH ° 1' - 4"1' - 4" STENCIL ON SITE FINISHED GRADE COLOR:WHITE 2' - 0" 2' - 3" ° 2 1/2" DIA. x 36" LONG ANCHOR BOLT 1' - 4"1' - 4" L 1" 4 (4 REQ'D) L 2' - 3"2' - 3" (5) 4" BARS ON A 16" PATTERN WITH 4" Y 2' - 0"2' - 0"3"1' - 0" 1' - 6"1' - 6" 3" E STIRRUPS ON 4" CENTERS FOR TOP 3" 6" W 2' - 9" MIN 16" AND 13"CENTERS THEREAFTER 3"3" 5' - 3" D K 5' - 0" DO NOT WELD REBAR 3' - 0" P L 3" MIN. CONC. COVER 1'-6" DIA PLAN L E 3 DIA .2 CU. YDS. OF CONC. REQ'D L 3 WAYFINDING GRAPHIC -DTE WAYFINDING GRAPHIC - Z E 0 A D6 ENTRY ARROW (BY GC)EXIT ARROW (BY GC) DIRECTIONAL SIGN FOOTING (BY GC)WAYFINDING GRAPHIC ARROW (BY GC) 4 5678 L H Scale:Scale:Scale:Scale: 1/2" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-0" E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 8' - 6"1 R 1 3 A 3 3"3' - 0"3"1' - 6"3"3' - 0"3" 1 1C 3" STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA NOTE: INSTALL PER MANUFACTURER'S Y10042 R LEED AP: INSTRUCTIONS. PRODUCTION DESIGNER: PETER CHEETHAM BIKE RACK EXISTING CHECKED BY: BY GC. CURB METAL BIKE RACK LEG Revision Schedule 4' - 0"3' - 6" RevDateByDescription ANCHORS WILL VARY ACCORDING TO INSTALL 2' - 6" SURFACE EXISTING C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SIDEWALK EXISTING METAL FLANGE CURB BASE PLATE 6' - 0" 3" SHEET TITLE: Y14093 SITE DETAILS THERMO PLASTIC BY GC AS SHOWN SCALE: SEE DETAIL 10/A-1004 FOR INSTALLATION SHEET NUMBER: ENLARGED BIKE RACKBIKE RACK INSTALLATION (BY GC)DTE - WAYFINDING GRAPHIC ORDER POINT STAR PATTERN (BY GC) 91011 Scale: 1/2" = 1'-0"Scale: 3" = 1'-0"Scale: 3/4" = 1'-0" A-1004 10/31/2017 6:16:02 PM SHEET NOTES SIGNAGE IS FOR REFERENCE ONLY EXTERIOR ELEVATION NOTES EXTERIOR SIGNAGE SCHEDULE - "S" SIGNAGE APPROVALS SHALL BE ACQUIRED UNDER SEPARATE 1.EXISTING EXTERIOR FINISHES TO REMAIN. REPAINT AS A.GENERAL CONTRACTOR TO COORDINATE AND SCHEDULE SIGN PERMIT SUBMITTALS. SIGNAGE IS NOT INCLUDED IN THE NECESSARY TO MATCH BUILDING. SIGNAGE INSTALLATION WITH THE SIGNAGE CONTRACTOR DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS SCOPE OF THE BUILDING PERMIT. PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS SIGNAGE - DRIVE THRU 2.EXISTING STOREFRONT WINDOW SYSTEM TO REMAIN. AND 1 WEEK PRIOR TO SCHEDULED DATE OF INSTALLATION. 140911SIGN - DT DIRECTIONAL EXIT SIGNSB-SBEXISTING FOOTING & CONDUIT, SIGN STARBUCKS CONSTRUCTION MANAGER TO PROVIDE ILLUMINATED ARROW SERIES - 46IN 1170MM(SB); SEE DETAIL:4/A-1004 EXISTING STOREFRONT DOOR & WINDOW SYSTEM TO 3. GENERAL CONTRACTOR WITH SIGNAGE CONTRACTOR 141061SIGN - DT CLEARANCE BAR ARROW SERIESSB-SBEXISTING FOOTING & CONDUIT, SIGN REMAIN. CONTACT INFORMATION. FREESTANDING(SB); SEE DETAIL: 2/A-1004 REMOVE DOOR AND INFILL WITH STOREFRONT TO MATCH 4. B.GENERAL CONTRACTOR SHALL COORDINATE WITH R EXISTING. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ELECTRICAL CIRCUITS INCLUDING ALL CONDUIT, WIRE, C 2017 STARBUCKS COFFEE COMPANY 5.EXISTING EXTERIOR WALL MOUNTED SCONCE TO REMAIN. CONNECTIONS, AND BREAKER AT PANEL BOARD NECESSARY TO SERVE SIGNAGE. EXTERIOR WALL TREATMENT (AREA) SCHEDULE - "Q" 6.REPLACE EXISTING AWNING FABRIC WITH NEW. PROVIDE STARBUCKS COFFEE BY SB. INSTALLATION BY GC. (COLOR : GREEN). C.GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD DESIGN IDAREADESCRIPTIONRESP.COMMENTS STUD BLOCKING, OR EQUIVALENT TO SUPPORT SIGNAGE. COMPANY EXTERIOR 7.NEW DRIVE-THRU WINDOW AND DT SHELF BY GC. 2401 UTAH AVENUE SOUTH X12107 SFBRICK - NATURALGC-GCCOLOR MATCH TO EXISTING PRIOR D.SIGNAGE CONTRACTOR SHALL VERIFY SIZE AND LOCATION TO CONSTRUCTION. CONTACT: MATT8.EXISTING BOLLARD TO REMAIN. OF ANY AND ALL ALLOWABLE MONUMENT OR POLE SIGNAGE SEATTLE, WASHINGTON 98134 MYER - EDGEWOOD BUILDING WITH LANDLORD AND PROVIDE SHOP DRAWING(S) PRIOR (206) 318-1575 SUPPLY 317-525-8718 9.EXISTING ELECTRICAL EQUIPMENT TO REMAIN. TO FABRICATION TO STARBUCKS DESIGNER FOR APPROVAL. THESE DRAWINGS AND SPECIFICATIONS ARE 10.EXISTING PLUMBING EQUIPMENT TO REMAIN. E. SIGNAGE CONTRACTOR TO INSTALL SIGNAGE IN CONFIDENTIAL AND SHALL REMAIN THE SOLE COMPLIANCE WITH LOCAL CODES AND OBTAIN PERMIT AND PROPERTY OF STARBUCKS CORPORATION, 11.EXISTING WORDMARK TO REMAIN. LANDLORD APPROVAL. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 12.LEASE LINE. F.SIGNAGE CONTRACTOR TO SUPPLY SHOP DRAWINGS TO REPRODUCED (IN WHOLE OR IN PART), SHARED STARBUCKS CONSTRUCTION MANAGER AND TO THE WITH THIRD PARTIES OR USED IN ANY MANNER 13.INSTALL NEW FINISH TO MATCH EXISTING BY GC. GENERAL CONTRACTOR AS NEEDED. GENERAL ON OTHER PROJECTS OR EXTENSIONS TO THIS CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION 151 X2101 Y PROJECT WITHOUT THE PRIOR WRITTEN 14.EXISTING INTERIOR SUSPENDED LOGO DISK TO REMAIN. MANAGER IMMEDIATELY IF SHOP DRAWINGS OR CONSENT OF STARBUCKS CORPORATION. TYP.TYP.TYP. INSTALLATION IS IN DISCREPANCY WITH STARBUCKS THESE DRAWINGS AND SPECIFICATIONS ARE 15.EXISTING SERVICE DOOR TO REMAIN. ARCHITECTURAL DRAWINGS. INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS 16.EXISTING DOWNSPOUT TO REMAIN. G.GENERAL CONTRACTOR TO CLEAN, PATCH AND REPAIR SUBJECT TO CHANGE AT ANYTIME) AND DO EXISTING EXTERIOR AS REQUIRED. NOT REFLECT ACTUAL SITE CONDITIONS. 17.EXISTING EXTERIOR SECURITY LIGHT TO REMAIN. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED 18.EXISTING EXTERIOR SECURITY CAMERA TO REMAIN. ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES 19.EXISTING WALL MOUNTED SPEAKER TO REMAIN. 18 STARBUCKS TEMPLATE VERSION i2017.08.25 19 20.EXISTING STORE ADDRESS ON SERVICE DOOR TO REMAIN. 5EXISTING REAR DOOR TO REMAIN. 21. Design Forum TYP. 22.NEW AIR-CURTAIN BY GC, DEMO PORTION OF WALL FOR 6 NEW AIR-CURTAIN. Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 1 Cincinnati, OH 45203Architect In Charge 23.REMOVE EXISTING EIFS AND INSTALL NEW. MATCH Tel: (513) 421-2210License: AR19700147 TYP. ADJACENT COLOR AND DEPTH. 1' - 4" 17 Design Forum Engineering RESPONSIBILITY LEGEND 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer 8' - 9" VIF SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR License: PE10504904 Tel: (513) 421-2210 6' - 8" SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY GENERAL CONTRACTOR Y10020 7 ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS NOTE: 816116882 1 DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION W14077M10894 722 TYP.TYP.TYP. TYP. SOUTH ELEVATION 1 Scale: 1/4" = 1'-0" 11/01/1709/01/17 L L Y 121711718 15111112 E W TYP. TYP.TYP. TYP.TYP. D K P L L E 3 L 3 Z E 0 19 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z 16 & , 16 A L 19' - 4" T H E 5 23 S 6 0 M 7 3' - 5" 23 1 TYP. R 1 3 A 3 1 1C STORE #:8123 6 5 PROJECT #:25450-048 TYP. ISSUE DATE: 11/1/17 13170 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule ET RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st QX1210 12199201510881141321 13 TYP. TYP.TYP.TYP. 2 4 SHEET TITLE: EXTERIOR ELEVATIONS ET= EXISTING TEMPERED GLAZING WEST ELEVATIONEAST ELEVATION 23 Scale: 1/4" = 1'-0"Scale: 1/4" = 1'-0" 1/4" = 1'-0" SCALE: 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" A-2001 10/31/2017 6:16:11 PM SHEET NOTESDEMOLITION FLOOR PLAN NOTES ITEMS TO DEMOLISH:ITEM TO PRESERVE: 1.ALL EXISTING CAFE FURNITURE AND FIXTURES TO BE REMOVED, UON. 16.EXISTING MENU BOARDS AND CUBBIES ABOVE TO BE REMOVED.A.IF DURING DEMOLITION CONDITIONS ARE REVEALED FRONT BARFRONT BAR COORDINATE WITH STARBUCKS CM FOR DISPOSAL OF FURNITURE THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR - COUNTERTOPS- POS EQUIPMENT FROM SITE.17.EXISTING CASEWORK AND BASE CABINETS BELOW TO BE PRECLUDE FOLLOWING DESIGN INTENT, GENERAL - UNDERCOUNTER CABINETS- ESPRESSO MACHINE (VERISMO/MASTRENA) (2) REMOVED, UON.CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION - STORAGE PASTRY CART- SECURITY SAFE WITH BASE EXISTING OUTDOOR FURNITURE AND UMBRELLAS TO BE REMOVED. MANAGER IMMEDIATELY. 2. - PASTRY CASE- 1-DOOR UNDERCOUNTER REFRIGERATOR (2) COORDINATE WITH STARBUCKS CM FOR DISPOSAL OF FURNITURE 18.GC TO SAWCUT FLOOR AS REQUIRED FOR INSTALLATION OF - CUP DISPENSER FROM SITE.NEW PLUMBING. COORDINATE WITH PLUMBING DRAWINGS.B.GENERAL CONTRACTOR RESPONSIBLE FOR SITE BACKBAR INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL BACKBAR- ESPRESSO MACHINE (VERISMO/MASTRENA) (1) COPE OF WORK. 3.EXISTING ARTWORK AND ANY MURAL GRAPHICS TO BE REMOVED.19.EXISTING FLOOR DRAIN TO BE REMOVED AND CAPPED. PATCH - COUNTERTOPS- GRINDER (1) R AND REPAIR FLOOR TO RECEIVE SCHEDULED FINISHES. - UNDERCOUNTER CABINETS - BREWER (1) 4.EXISTING FLOORING, TILE BASE & WALL FINISHES/ TILE TO BE C.EXISTING WALLS TO REMAIN. PATCH AND REPAIR AS - MENU BOARDS AND CUBBIES- SHUTTLES (2) C 2017 STARBUCKS COFFEE COMPANY REMOVED. GC TO PATCH & REPAIR WALLS TO PREPARE FOR REQUIRED TO PROVIDE A SMOOTH, PAINT READY 20.EXISTING PATIO RAILING TO REMAIN, UON. - 2-DOOR UNDERCOUNTER REFRIGERATOR (1)- BLENDERS (2) NEW FINISHES.FINISH. - SCALE (1) 21.EXISTING SECURITY SAFE AND BASE TO BE RELOCATED PER WORKROOM - 1-DOOR UNDERCOUNTER REFRIGERATOR (2) STARBUCKS COFFEE EXISTING PROMOTIONAL BANNER TO BE REMOVED.DEMOLISH EXISTING WALLS AND DOORS AS DIRECTED. 5.FF&E PLAN.D. - THAW RACK - STORAGE PASTRY CARTWORKROOM COMPANY 6.EXISTING NEWSPAPER STAND TO BE RELOCATED PER FF&E PLAN.22.EXISTING GRINDER AND SCALE TO BE RELOCATED PER FF&E E.DEMOLISH EXISTING FLOOR FINISHES AS DIRECTED. - ICE MACHINE- METRO RACKS (6) PLAN.REPAIR OR REPLACE SUB-FLOOR AS REQUIRED TO - MOP SINK- 3-COMP SINK 2401 UTAH AVENUE SOUTH EXISTING CONDIMENT CART TO BE REMOVED. COORDINATE WITH PROVIDE AN EVEN WALKING SURFACE/FINISH FLOOR 7. - 1-DOOR REFRIGERATOR (1)- WATER HEATER AND WATER FILTRATION SYSTEM SEATTLE, WASHINGTON 98134 STARBUCKS CM FOR DISPOSAL.23.EXISTING WORKROOM FURNITURE, FIXTURE AND EQUIPMENT CONDITION. - 1-DOOR FREEZER (1)- 2-DOOR REFRIGERATOR (1) (206) 318-1575 TO BE REMOVED, UON. - 2-DOOR FREEZER (1) EXISTING TRASH CAN/ RECYCLE BIN TO BE REMOVED.DEMOLISH EXISTING GYPSUM WALL BOARD, CEILING 8.F. CAFE- HAND SINK THESE DRAWINGS AND SPECIFICATIONS ARE 24.EXISTING PASTRY CASE TO BE REMOVED.TILE, GRID AND/OR OTHER CEILING FINISH AS - CONDIMENT CART- FIRE EXTINGUISHER (1) CONFIDENTIAL AND SHALL REMAIN THE SOLE 9.EXISTING RESTROOM FIXTURE AND ACCESSORIES TO BE REMOVED.DIRECTED TO PROVIDE FOR NEW CEILING READY - FURNITURE- DISHWASHER/ SANITIZER PROPERTY OF STARBUCKS CORPORATION, 25.CONDITION. EXISTING STORAGE PASTRY CART TO BE REMOVED. - MERCH BAYS (3) WHICH IS THE OWNER OF THE COPYRIGHT IN 10.EXISTING INTERIOR WALLS TO BE REMOVED PER NEW SCOPE OF - MERCH CUBES AND BASKETS THIS WORK. THEY SHALL NOT BE WORK, UON. PATCH AND REPAIR ADJACENT WALLS AS REQUIRED.26.EXISTING POS EQUIPMENT TO BE RELOCATED PER FF&E PLAN.G.DEMOLISH EXISTING WALL FINISHES AS DIRECTED. - NEWSPAPER STAND AND PROMO BANNER REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER REMOVE EXISTING LIGHT FIXTURES, EQUIPMENT AND 11.EXISTING STOREFRONT WINDOW SYSTEM TO REMAIN. GC TO 27.EXISTING MASTRENAS TO BE RELOCATED PER FF&E PLAN.H. PATIO ON OTHER PROJECTS OR EXTENSIONS TO THIS CLEAN AND REPLACE SEALS AND HARDWARE AS REQUIRED.POWER LINES AS DIRECTED. - FURNITURE PROJECT WITHOUT THE PRIOR WRITTEN 28.EXISTING BLENDERS TO BE RELOCATED PER FF&E PLAN. - UMBRELLA WITH BASE CONSENT OF STARBUCKS CORPORATION. REMOVE EXISTING PLUMBING FIXTURES AS DIRECTED. 12.EXISTING MERCH BAYS TO BE REMOVED.I. THESE DRAWINGS AND SPECIFICATIONS ARE 29.EXISTING CUP LABELER TO BE RELOCATED PER FF&E PLAN.CAP LINES AS DIRECTED FOR THOSE NOT BEING INTENDED TO EXPRESS DESIGN INTENT FOR A 13.EXISTING MERCH BASKETS AND CUBES TO BE REMOVED.RE-USED. PROTOTYPICAL STARBUCKS STORE (WHICH IS 30.EXISTING BREWER AND SHUTTLES TO BE RELOCATED PER SUBJECT TO CHANGE AT ANYTIME) AND DO GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF SIZE 14.EXISTING WATER FILTRATION SYSTEM TO BE RELOCATED PER FF&E PLAN.J. NOT REFLECT ACTUAL SITE CONDITIONS. FF&E PLAN.OF EXISTING RESTROOM AND LOCATION AND CONDITION NEITHER PARTY SHALL HAVE ANY OBLIGATION 31.EXISTING DT WINDOW AND AIR-CURTAIN TO BE REMOVED.OF FIXTURES PRIOR TO DEMOLITION OR CONSTRUCTION. NOR LIABILITY TO THE OTHER (EXCEPT STATED PLUMBING FIXTURES TO BE RE-USEDARE TO BE REMOVED 15.EXISTING FIRE EXTINGUISHER TO BE RELOCATED PER ABOVE) UNTIL A WRITTEN AGREEMENT IS FF&E PLAN.32.EXISTING METRO RACKS TO BE RELOCATED PER FF&E PLAN. AND PROPERLY STORED FOR RE-INSTALLATION. FULLYEXECUTEDBYBOTHPARTIES 33.K.LABEL ALL ITEMS TO BE PROPERLY STORED FOR EXISTING THAW RACK TO BE REMOVED. RE-INSTALL. STARBUCKS TEMPLATE VERSION i2017.08.25 34.EXISTING ELECTRICAL PANEL TO REMAIN. 35.EXISTING WALK-OFF MAT TO BE REMOVED. REPAIR/ REPLACE Design Forum SUB-FLOOR AS REQUIRED TO PROVIDE EVEN FINISH, FOR 43 NEW WALK-OFF MAT AND FLOOR FINISHES. Architects Inc. 36.EXISTING DOOR AND DOOR FRAME TO BE REMOVED. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge 37. EXISTING RESTROOM SIGNAGE TO BE REMOVED. Tel: (513) 421-2210License: AR19700147 38.EXISTING LOCATION OF ALL SWITCHING TO BE RELOCATED PER FF&E PLAN. Design Forum 34 39.EXISTING 2-DOOR FREEZER TO BE RELOCATED PER FF&E WALL DEMOLITION LEGEND PLAN. Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE MATERIAL TO BE DEMOLISHED 40.EXISTING 2-DOOR REFRIGERATOR TO BE RELOCATED PER Cincinnati, OH 45203Professional Engineer 50 License: PE10504904 FF&E PLAN. Tel: (513) 421-2210 11 MATERIAL TO BE RELOCATED WITHIN SAME SITE 41.EXISTING 10-COMP LOCKER TO BE RELOCATED PER FF&E PLAN. EXISTING WALL TO REMAIN 42.EXISTING STOREFRONT DOOR WINDOW SYSTEM TO REMAIN. EXPANSION SPACE GC TO CLEAN AND REPLACE SEALS AND HARDWARE AS EXISTING COLUMN TO REMAIN 44 REQUIRED. 43.EXISTING STOREFRONT DOOR TO BE REMOVED. 44.DEMOLISH ALL EXISTING WALLS, DOORS AND FINISHES IN THE EXPANSION SPACE. 11/01/1709/01/17 45.EXISTING WORKROOM HAND SINK TO BE RELOCATED AS PER 1010 FF&E PLAN. 46.EXISTING MANAGER DESK, SHELF AND DATA RACK TO BE REMOVED. RELOCATE DATA AND COMMUNICATION DEVICES L 121212 MEN'S WOMEN'S 6 PER FF&E PLAN. 10 L RESTROOMRESTROOM Y 41 13 47.EXISTING MOP PRINTER TO BE RELOCATED AS PER FF&E PLAN. E 49 49 5 W 13 1414 D 8 8 48.EXISTING 3-COMP SINK TO BE RELOCATED AS PER FF&E PLAN. K 10 19 42 10 P 35 19 L 49. EXISTING 1-DOOR REFRIGERATOR TO BE RELOCATED PER 4536 L FF&E PLAN. E 3 34 36 CAFE/SEATING L 3 37 Z E 8 50. EXISTING EXTERIOR DOOR TO REMAIN. GC TO VERIFY DOOR IS IN 0 134 GOOD WORKING ORDER. A D6 RESTROOM WORKROOM 4 L VESTIBULE H 50 42319 E 25 N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 4 29 Z 13 & 7 , A L 15 T 48 H E 3232 PATIO S 0 M 7 RETAIL 2 1 R 1 101313 3 A 19 3 1 1C 3232 22 19 27 2749 STORE #:8123 46 24 PROJECT #:25450-048 BEVERAGE 38 32 ISSUE DATE: 11/1/17 13 PREP. 11DESIGNER: LISA MACEDA R LEED AP: 21 26294161718 25 10 33 PRODUCTION DESIGNER: PETER CHEETHAM 47 CHECKED BY: 19 30 27 32 49 49 10 Revision Schedule 26 RevDateByDescription 26 3940 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 20 11 223028 SHEET TITLE: 31 DEMOLITION FLOOR PLAN DEMOLITION FLOOR PLAN 1 N 1/4" = 1'-0" SCALE: Scale: 1/4" = 1'-0" 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" I-1101 10/31/2017 6:20:09 PM DEMOLITION CEILING PLAN NOTES A.IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY. B.GENERAL CONTRACTOR RESPONSIBLE FOR SITE R INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. C 2017 STARBUCKS COFFEE COMPANY C.EXISTING WALLS TO REMAIN. PATCH AND REPAIR AS REQUIRED TO PROVIDE A SMOOTH, PAINT READY FINISH. STARBUCKS COFFEE D.DEMOLISH EXISTING GYPSUM WALL BOARD, CEILING TILE, COMPANY GRID AND/OR OTHER CEILING FINISH AS NECESSARY TO PROVIDE FOR NEW CEILING READY CONDITION. 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 E.DEMOLISH EXISTING WALL FINISHES AS NECESSARY. (206) 318-1575 F.REMOVE EXISTING LIGHT FIXTURES, AUXILIARY THESE DRAWINGS AND SPECIFICATIONS ARE EQUIPMENT/ FIXTURES AND POWER LINES AS NECESSARY. CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, G.REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS SHEET NOTES PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE 1.EXISTING 2' X 4' ACT CEILING TO REMAIN. PATCH AND INTENDED TO EXPRESS DESIGN INTENT FOR A REPAIR CEILING AS REQUIRED FOR NEW WORK. PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 2.PORTION OF EXISTING ACT CEILING TO BE REMOVED. NOT REFLECT ACTUAL SITE CONDITIONS. PATCH AND REPAIR CEILING AS REQUIRED FOR NEW NEITHER PARTY SHALL HAVE ANY OBLIGATION WORK. NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS 3.EXISTING 2' X 2' ACT CEILING/ SOFFIT TO BE REMOVED. FULLYEXECUTEDBYBOTHPARTIES PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED FOR NEW WORK. STARBUCKS TEMPLATE VERSION i2017.08.25 EXISTING GYPSUM BOARD CEILING TO BE REMOVED. 4. 24 PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED FOR NEW WORK. Design Forum 5.EXISTING EXIT SIGN AND/ OR EMERGENCY LIGHTS TO EXPANSION SPACE REMAIN. 7 Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman EXISTING EXIT SIGN AND/ OR EMERGENCY LIGHTS TO BE 6. Cincinnati, OH 45203Architect In Charge RELOCATED. Tel: (513) 421-2210License: AR19700147 25 7.DEMOLISH ENTIRE CEILING INCLUDING ALL LIGHITNG FIXTURES AND MECHANICAL EQUIPMENT IN EXPANSION SPACE. Design Forum 8.EXISTING TRACK LIGHTS TO BE REMOVED. Engineering 9.EXISTING RECESSED TROFFER LIGHTS TO REMAIN. 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer MEN'S WOMEN'S 12 10.EXISTING LOCATION OF ALL SWITCHING. License: PE10504904 Tel: (513) 421-2210 RESTROOMRESTROOM 13 14 11.EXISTING RECESSED CAN LIGHTS TO BE REMOVED. GYP. BD. CEILING 1112 1919 AT 9' - 0" AFF TYP. OF 2 12.EXISTING RESTROOM WALL SCONCES TO BE REMOVED. 4 8 11 8 85 13.EXISTING WALL MOUNTED SPEAKERS TO REMAIN. TYP. OF 2 6 6 14.EXISTING WALL MOUNTED SPEAKERS TO BE RELOCATED. 26 18 18 18 15.EXISTING SECURITY CAMERAS TO REMAIN. 11 2 16.EXISTING SECURITY CAMERAS TO BE RELOCATED. 1118 8 8 11/01/1709/01/17 RESTROOM TYP. OF 14 17.EXISTING HVAC SUPPLY/ RETURN DIFFUSER GRILLES VESTIBULE 15 TO REMAIN. 5 14 18.EXISTING HVAC SUPPLY/ RETURN DIFFUSER GRILLES TO BE RELOCATED. CAFE/SEATING L (E)2' X 4' ACT CEILING 20 RETAIL L 19.EXISTING HVAC SUPPLY/ RETURN DIFFUSER GRILLES AT 9' - 10" AFF Y TYP. OF 8 TO BE REMOVED. E 2 1 18 W 11 2' X 2' ACT CEILING D 20.EXISTING ROLLER SHADES TO BE REMOVED. K AT 10' - 5 3/8" AFF TYP. OF 11 9 WORKROOM P L 16 21.EXISTING INTERIOR SUSPENDED LOGO DISK TO REMAIN. 3 TYP. OF 4 21 17 L 25 E 3 L 22.EXISTING EXTERIOR WALL SCONCES TO REMAIN. 3 11 Z E 15 0 TYP. OF 7 23.EXISTING EXTERIOR AWNING TO REMAIN. FABRIC TO BE A D6 10 REPLACED. 4 L BEVERAGE H 2' X 2' ACT SOFFIT 88 E N AT 8' - 4 3/4" AFF24.EXISTING EXTERIOR ADJACENT TENANT SIGNAGE TO BE PREP. I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z REMOVED. & , 3 A L 25.EXISTING EXTERIOR SECURITY LIGHTS TO REMAIN. T 27 H E 28 S 0 M 26.EXISTING EXTERIOR WORDMARK TO REMAIN.. 7 1 R 1616 13 1 27.EXISTING DT AIR-CURTAIN TO BE REMOVED. 3 A 3 1 1C 22 28.EXSITING CEILING FEATURES TO BE REMOVED. TYP. OF 2 STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA 23 22 R LEED AP: CEILING LEGEND - DEMO PLAN TYP. OF 3 PRODUCTION DESIGNER: PETER CHEETHAM 2' X 2' ACT SOFFIT GYP. BD. CEILING CHECKED BY: AT 9' - 5" AFF AT 9' - 0" AFF MATERIAL TO BE DEMOLISHED. 3 4 Revision Schedule EXISTING CEILING/ MATERIAL TO REMAIN. RevDateByDescription MATERIAL TO BE RELOCATED WITHIN SAME SITE. C:\\Users\\zach.scholl\\Documents\\Starbucks_131st EXISTING COLUMN TO REMAIN DEMOLITION CEILING PLAN SHEET TITLE: 1 N Scale: 1/4" = 1'-0" DEMOLITION CEILING PLAN 1/4" = 1'-0" SCALE: 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" I-1102 10/31/2017 6:20:32 PM WALL TYPES LEGEND INTERIOR FLOOR PLAN NOTES New Partition Wall to 6" above ceiling 11 New Partition Wall up to 10'-0" AFF 17 Existing Wall - Patch & Repair To "Like New" Condition. 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. up to 10'-0" 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. with 5/8" A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY AFF with 5/8" (16 mm) moisture resistant gypsum board on both side (16 mm) moisture resistant gypsum board on both side to 6" STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES to 6" above ceiling. Secure gypsum board to studs with drywall above ceiling. Secure moisture resistant gypsum board to New Partition Wall to structure above 2 4 7/8" PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM 4 7/8" studs with drywall screws at 10" (254 mm) O.C. at panel edges screws at 10" (254 mm) O.C. at panel edges and 12" (305 mm) O.C. 20 Ga 6" (152 mm) metal studs 16" (406 mm) O.C. to structure with DESIGNATED DATUM POINT. at intermediate supports. and 12" (305 mm) O.C. at intermediate supports. Provide 45 5/8" (16 mm) moisture resistant gypsum board on both sides to 6" degree metal stud Diagonal Bracing @ 48" (1219 mm) O.C. 7 1/4" above ceiling. Secure gypsum board to studs with drywall screws at B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD New Partition Wall to 6" above ceiling From top of stud wall to structure above. 10" (254 mm) O.C. at panel edges and 12" (305 mm) O.C. at 8 BLOCKING, OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. with 5/8" (16 mm) intermediate supports. AND/OR SIGNAGE. moisture resistant gypsum board on one side and type "X" gypsum New Partial Height Wall - Heavier Gauge Stud To 2'-0" 12 board on other side to 6" above ceiling. Secure gypsum board to studs R D. ALL DOORS TO PROVIDE 36Ñ (915MM) MINIMUM CLEAR OPENING 4 7/8" New Partition Wall to structure above with drywall screws at 10" (254 mm) O.C. at panel edges and 12" (305 3 16 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. with 5/8" WHEN OPENED TO 90 DEGREE POSITION UNLESS OTHERWISE mm) O.C. at intermediate supports. Provide 45 degree metal stud 20 Ga 6" (152 mm) metal studs 16" (406 mm) O.C. to structure with C 2017 STARBUCKS COFFEE COMPANY 4 7/8" (16 mm) moisture resistant gypsum board on both sides. NOTED. Diagonal Bracing @ 48" (1219 mm) O.C. From top of stud wall to 5/8" (16 mm) moisture resistant gypsum board on one side and type Drywall screws @ 12" (305 mm) O.C. structure above. "X" Gyp. board on other side to 6" above ceiling. Secure gypsum 7 1/4" E. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS COFFEE board to studs with drywall screws at 10" (254 mm) O.C. at panel STARBUCKS AND/OR CODE REQUIREMENTS. New Partition Wall to 6" Above Ceiling edges and 12" (305 mm) O.C. at intermediate supports. 13 9New Partition Wall to 6" above ceiling COMPANY 20 Ga 3 5/8" (92 mm) metal studs 16" (406 mm) O.C. with 5/8" F. INSTALL 1/4" (6MM) GREEN BOARD ON BACKBAR WALL PER 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. with 5/8" (16 mm) (16 mm) moisture resistant gypsum board on both sides to 6" SPECIFICATION. New Partition Wall to 6" above ceiling 2401 UTAH AVENUE SOUTH 4Type "X" gypsum board on both sides to 6" above ceiling. Secure above ceiling. Secure moisture resistant gypsum board to studs 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. up to 10'-0" AFF SEATTLE, WASHINGTON 98134 gypsum Board to studs with drywall screws at 10" (254 mm) O.C. at 4 7/8" with drywall screws at 10" (254 mm) O.C. at panel edges and G.ALL DIMENSIONS ARE TO FINISHED FACE UNLESS SHOWN OR 4 7/8" with 5/8" (16 mm) plywood substrate on one side only to 6" above panel edges and 12" (305 mm) O.C. at intermediate supports. Provide 12" (305 mm) O.C. at intermediate supports. Provide 45 degree (206) 318-1575 NOTED OTHERWISE. 4 1/4" ceiling. Secure plywood board to studs with drywall screws at 10" (254 45 degree metal stud Diagonal Bracing @ 48" (1219 mm) O.C. From metal stud Diagonal Bracing @ 48" (1219 mm) O.C. From top of mm) O.C. at panel edges and 12" (305 mm) O.C. top of stud wall to structure above. stud wall to structure above. THESE DRAWINGS AND SPECIFICATIONS ARE H.SEE SHEET A-6001 FOR EXTERIOR DOOR AND WINDOW SCHEDULES. CONFIDENTIAL AND SHALL REMAIN THE SOLE SEE SHEET A-1101 FOR TAGGED LOCATIONS OF EXTERIOR PROPERTY OF STARBUCKS CORPORATION, WINDOWS AND DOORS. New furred Wall to 6" Above Ceiling New Partition Wall to 6" above ceiling 5 WHICH IS THE OWNER OF THE COPYRIGHT IN 14 10New Plumbing Wall to 6" Above Ceiling 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. up to 10'-0" 20 Ga 6" (152 mm) metal studs 16" (406 mm) O.C. with 5/8" (16 mm) THIS WORK. THEY SHALL NOT BE I.STARBUCKS VENDOR TO PROVIDE HARDWARE SCHEDULE AND AFF with 5/8" (16 mm) moisture resistant gypsum board on one side 20 Ga 6" (152 mm) metal studs 16" (406 mm) O.C. with 5/8" (16 mm) moisture resistant gypsum board on one side to drywall ceiling above REPRODUCED (IN WHOLE OR IN PART), SHARED HARDWARE COMPONENTS. GC TO INSTALL. 4 1/4" only to 6" above ceiling. Secure gypsum board to studs with drywall moisture resistant gypsum board on both sides to drywall ceiling above And/ OR to min. 6" above lay-in ceiling as applicable. Secure WITH THIRD PARTIES OR USED IN ANY MANNER screws at 10" (254 mm) O.C. at panel edges and 12" (305 mm) O.C.6 3/4" And/ OR to min. 6" above lay-in ceiling as applicable. Secure moisture moisture resistant gypsum board to studs with drywall screws at 10" ON OTHER PROJECTS OR EXTENSIONS TO THIS resistant gypsum board to studs with drywall screws at 10" (254 mm) (254 mm) O.C. at panel edges and 12" (305 mm) O.C. at PROJECT WITHOUT THE PRIOR WRITTEN 7 1/4" O.C. at panel edges and 12" (305 mm) O.C. at intermediate supports. intermediate supports. CONSENT OF STARBUCKS CORPORATION. New Partition Wall up to 10'-0" AFF, Wall start @ 2'-10" AFF SHEET NOTES 6 Provide 45 degree metal stud Diagonal Bracing @ 48" (1219 mm) O.C. THESE DRAWINGS AND SPECIFICATIONS ARE 20 Ga 3-5/8" (92 mm) metal studs 16" (406 mm) O.C. up to 10'-0" From top of stud wall to structure above. INTENDED TO EXPRESS DESIGN INTENT FOR A AFF with 5/8" (16 mm) moisture resistant gypsum board on both 1.EXISTING STOREFRONT DOOR & WINDOW SYSTEM TO REMAIN. New furred Wall to 6" Above Ceiling PROTOTYPICAL STARBUCKS STORE (WHICH IS sides to 6" above ceiling. Secure gypsum board to studs with drywall 4 7/8"15 SUBJECT TO CHANGE AT ANYTIME) AND DO 20 Ga 2-1/2" (152 mm) metal studs 16" (406 mm) O.C. with 5/8" (16 screws at 10" (254 mm) O.C. at panel edges and 12" (305 mm) O.C. 2.EXISTING ELECTRICAL PANELS TO REMAIN. NOT REFLECT ACTUAL SITE CONDITIONS. mm) Type "X" gypsum board on one side to drywall ceiling above at intermediate supports. NOTE: NEITHER PARTY SHALL HAVE ANY OBLIGATION And/ OR to min. 6" above lay-in ceiling as applicable. Secure gypsum 3.ALIGN FACE OF FINISHED WALL. NOR LIABILITY TO THE OTHER (EXCEPT STATED board to studs with drywall screws at 10" (254 mm) O.C. at panel SEE SHEET I-5001 & I-5002 FOR WALL CONSTRUCTION ABOVE) UNTIL A WRITTEN AGREEMENT IS 3 1/8" edges and 12" (305 mm) O.C. at intermediate supports. 4.EXISTING STOREFRONT WINDOW TO REMAIN. DETAILS. FULLYEXECUTEDBYBOTHPARTIES 5.EXISTING REAR EXTERIOR DOOR TO REMAIN. SEE HARDWARE SET # STARBUCKS TEMPLATE VERSION i2017.08.25 12 ON SHEET I-1103.1. 57' - 11" VERIFY PRIOR TO CONST. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCY 6.GC TO VERIFY OVERALL DIMENSION OF SPACE PRIOR TO LAYING OUT WALLS. CONTACT ARCHITECT IMMEDIATELY IF DISCREPANCIES Design Forum OCCUR. Architects Inc. 7.EXISTING REAR SERVICE DOOR. GC TO RE-PAINT EXISTING COLOR. 1 700 W. Pete Rose Way, Suite 460Donald J. Rethman 14 F GA Cincinnati, OH 45203Architect In Charge 8. DRIVE-THRU WINDOW BY GC. Tel: (513) 421-2210License: AR19700147 W01 11 14L MEN 9.EXTEND WALL BELOW AND ABOVE WINDOW AS REQUIRED. RAISE 5 3' - 4" LINTEL AS INDICATED ON SHEET A-1003. RESTROOM I-1103.1 8 Design Forum 5' - 7" D 10 10.PROVIDE FIRE TREATED WOOD BLOCKING AS REQUIRED TO SUPPORT ANY WALL ATTACHMENTS. D 88 D10190 Engineering 11.NEW STOREFRONT WINDOW SYSTEM TO MATCH EXISTING, BY GC. 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer 13 2 9 License: PE10504904 Tel: (513) 421-2210 12. EXISTING STRUCTURAL COLUMN TO REMAIN. GC. TO VERIFY 6' - 8"3' - 0"2' - 8" 1' - 8 1/2" LOCATION. HALLWAY 13. GC TO PROVIDE LOCK FOR ELECTRICAL PANEL. PAINT TO MATCH 9 1514 3' - 0" ADJACENT WALL FINISH. OPENING 6' - 8"3' - 0"2' - 8" 14.ALIGN FURRED WALL WITH FACE OF ELECTRICAL PANEL. 4 9 5 WALL BLOCKING KEY 88 D D10190 1' - 2" 8 SYMBOLITEMWEIGHTHEIGHTAPPROXIMATE WIDTH D WOMEN CAFE/SEATING 11/01/1709/01/17 L RESTROOM Restroom Hand Sink200LBS3'-0" to 3'-4"2'-6" Behind Sink A 610 5' - 11 1/2" 14 10 Shelves Above 3- 200LBS5'-8" to 6'-0"6'-0" Centered Above B FGA Comp Sink 103 3-Comp Sink L 12 Data Rack at Manager's 300LBS3'-9" to 7'-2"7'-0" Centered Above C L DeskManager's Desk and Y E Data Rack 1 W D Restroom Grab Bars250LBS2'-6" to 3'-0"5'-0" Around WC D K 4' - 6" P Extent of Backbar DT POS Upper cubby L E300LBS5'-0" to 6'-7" Upper Casework L E 3 1 L 3 Diaper Changing Station250LBS2'-4" to 4'-0"See Plan and Restroom F Z E 0 Details 1 A D6 13' - 2" G 4 200LBS3'-0" to 4'-0"2'-0" Starting 6" From Restroom Hand Dryer L 2 H Wall Corner RETAIL E N 3 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z Water Filtration System4'-0" to 6'-6"See Plan200LBS H & , A L T 7 H E Workroom Handsink125LBS3'-0" to 3'-4"5'-7" infront of 3-Comp Sink I J S 0 M 7 1 R BEVERAGE L Water Chiller300LBS6'-4" to 7'-11"See Plan J 1 3 A 3 PREP. 1 1C Upper Storage Floating Extent of Backbar 15' - 11"300LBS5'-0" to 6'-4" 10 K Shelves/CBE ShelfUpper Casework WORKROOM 3 STORE #:8123 10 1/2" C 3' - 6" 10 Artwork/ Community 100LBS3'-0" to 7'-10"Extent of Art/Mural Frame 13 L OPENING PROJECT #:25450-048 1' - 1 1/2" Board 8' - 2 1/2" ISSUE DATE: 11/1/17 22' - 11 1/2"1' - 3 1/2"6' - 10" 4 DESIGNER: LISA MACEDA - Provide fire treated 2x6 or 2x8 wood stud blocking as required to support any wall attachments. OPENING R 1 LEED AP: 2 4 - See interior elevations for correct locations. 3' - 0" PRODUCTION DESIGNER: PETER CHEETHAM KK 6 2 ICHECKED BY: PATIO 4 77 INTERIOR WALL LEGEND 5 Revision Schedule BB 4 ABOVE 5' - 11"10' - 1" NEW FULL HEIGHT WALL RevDateByDescription 3 2 3' - 11" E 9' - 6" NEW PARTIAL HEIGHT WALL C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 7' - 4 1/2"7' - 4 1/2" 1 89 EXISTING WALL 5' - 11 1/2" 3 14077 W 1112111 H 4 WALL TAG # 11 2' - 6 1/4" 2' - 4 1/4" 1SHEET TITLE: FLOOR PLAN #WALL BLOCKING KEY 8' - 7"4' - 0"2' - 5" 1/4" = 1'-0" SCALE: #WINDOW TAG SHEET NUMBER: N FLOOR PLAN 02'4'8' DATUM POINT 1 Scale: 1/4" = 1'-0" I-1103 Scale: 1/4" = 1'-0" 10/31/2017 6:20:34 PM INTERIOR DOOR LEGEND INTERIOR DOOR SCHEDULE - "D" 3' - 4" EXISTING WALL VIF DESIGNCONST.DOORFRAMEFRAMEFIRE IDTYPEFINISHFINISHMATERIALRATING COUNTDESCRIPTIONRESP.COMMENTS SHIM AND 4 101902DOOR - SINGLETYPE EWD0073X1202-SGMTLNAGC-GCREFER RESTROOMSILICONE BEAD FLUSH - 36INDOOR (TYPE E) AND I-1103.1 HARDWARE SET #6 CENTERLINE OF NEW R MULLION @ EXISTING MULLION C 2017 STARBUCKS COFFEE COMPANY 2" TYPE E STARBUCKS COFFEE TYPE G COMPANY WINDOW SCHEDULE - "W" 2401 UTAH AVENUE SOUTH DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS RESTROOM DOOR (TYPE E) SEATTLE, WASHINGTON 98134 WINDOW SET #6 (206) 318-1575 3 140771WINDOW - DT WITH OPEN TRANSOM - 48X60INGC-GCUSE IN CONJUNCTION WITH AA300 (1) CYLINDRICAL PRIVACY LATCHSET: BRONZE FINISH 1205X1510MM - ALUMINUMHEATED AIR CURTAIN; BLACK (3) DOOR HINGES 4.5 X 4.5 (NRP): BRONZE FINISH (PAINT TO MATCH I-1103.1 6' - 6"6' - 2" NEW ALUMINUM THESE DRAWINGS AND SPECIFICATIONS ARE LATCHSET) VESTIBULE SYSTEM BY CONFIDENTIAL AND SHALL REMAIN THE SOLE (1) DOOR CLOSURE: UNIVERSAL HARDWARE - MODEL 4032 BRONZE SB. FINISH & FRAMING TO PROPERTY OF STARBUCKS CORPORATION, (1) DOOR STOP WITH HOOK: ROCKWOOD 473, 613/613E FINISH (MATCH 1 MATCH EXISTING. WHICH IS THE OWNER OF THE COPYRIGHT IN LATCHSET) I-1103.1 THIS WORK. THEY SHALL NOT BE (1) KICK PLATE 10X34: ROCKWOOD 10X34, 613/613E FINISH (MATCH 2 ALUMINUM FRAMING TO MEET AS REPRODUCED (IN WHOLE OR IN PART), SHARED LATCHSET) 2 SHOWN. GC TO PROVIDE CONNECTION WITH THIRD PARTIES OR USED IN ANY MANNER I-1103.1 (1) RUBBER SILENCER: GLENN-JOHNSON 64 CONSISTENT WITH MANUFACTURER ON OTHER PROJECTS OR EXTENSIONS TO THIS 1 T 2" SPECIFICATIONS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE REAR EGRESS DOOR (TYPE G) INTENDED TO EXPRESS DESIGN INTENT FOR A SET #12 PROTOTYPICAL STARBUCKS STORE (WHICH IS GC SHALL SUPPLY HARDWARE FOR REAR EGRESS DOOR AS FOLLOWS: SUBJECT TO CHANGE AT ANYTIME) AND DO (1) DOOR CLOSER 8916 AF89P AL DORMA NOT REFLECT ACTUAL SITE CONDITIONS. (1) 1/0 2000L-031C SUR-LOCK AUTO LOCKING DOOR ALARM, 1C; NO CTR W01CONNECTION PLAN DETAIL NEITHER PARTY SHALL HAVE ANY OBLIGATION INCLUDES MORTISE CYLINDER 1 Scale: 3" = 1'-0" NOR LIABILITY TO THE OTHER (EXCEPT STATED (1) NGP WEATHER STRIP, SIZE O FOR DOOR ABOVE) UNTIL A WRITTEN AGREEMENT IS (1) KICK PLATE - 24" H X 34" L FULLYEXECUTEDBYBOTHPARTIES (1) PANIC HARDWARE - FALCON 1790 TOUCHBAR RIM EXIT DEVICE STARBUCKS TEMPLATE VERSION i2017.08.25 Design Forum Architects Inc. DOOR LEGEND 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge 4 1/2" Tel: (513) 421-2210License: AR19700147 175-001 PERIMETER MULLION Construction:Glazing:Frame: 175-156 COVER 175-314 PERIMETER FILLER SC=Solid CoreT=Solid CoreAL =Aluminum Storefront Design Forum HM=Hollow MetalW=Hollow MetalHM1 =Hollow Metal Single Rabbet 128-200 SPLINE SCREW AL=Aluminum StorefrontHM2 =Hollow Metal Double Rabbet WD= Wood StorefrontRating:HM3 =Hollow Metal Single Rabbet for CMU EXTERIORINTERIOR Engineering E=ExistingHM4 =Hollow Metal No Rabbet 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE NR =Non-Rated Cincinnati, OH 45203Professional Engineer 1HR =1 hour License: PE10504904 SHIM AS REQUIRED -EXISTING EXTERIOR Tel: (513) 421-2210 2HR =2 hour STRUCTURE AND PROVIDE BACKER Miscellaneous: ROD AND SEALANTFINISH PROVIDE FLEXIBLE SEALANT U=1/2" Undercut 9'-9" AFF B/O ACT CEILING (E)9'-4" AFF (VIF) T/O STOREFRONT WINDOWCOUNTMATERIALLINTELRESP.COMMENTS GLAZING DETAIL @ BOTTOM FRAMEFINISHGLAZING 2 Scale: 3" = 1'-0" ALUMBLACK W 011INSUL/TEMPGC - GCKAWNEER EXISTING 4 TRIFAB VG 451 I-1103.1 11/01/17 09/01/17 EXTERIOR GENERAL NOTES: HEAD 1"INFILL L 1. SEALANT TO MATCH ANODIZED ALUMINUM STOREFRONT SYSTEM. L 2. FIELD VERIFY ALL DIMENSIONS PRIOR TO STOREFRONT MANUFACTURING. O.D. Y . E F.H.1/4" ABBREVIATIONS: PROVIDE FLEXIBLE W D DLO2" SEALANT K -ALUM: ALUMINUM-TEMP: TEMPERED GLASS P L 6' - 6" -ANOD: ANODIZED-INSUL: INSULATED GLASS L E 3 L GLAZING NOTES: 3 NEW EXTERIOR Z E 0 WINDOW 1" INSULATED TEMPERED CLEAR GLAZING. ALL GLAZING TO BE PPG A D6 1 SHIM AS REQUIRED - 4 SOLARBAN 60 (2) CLEAR + CLEAR, OR EQUAL. L H PROVIDE BACKER E N ROD AND SEALANT2 2 GC TO VERIFY COMPATIBILITY W/(E) STOREFRONT SYSTEM. I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & I-1103.1 , INTERIOR A L T H E 175-001 PERIMETER MULLION WINDOW SILL TOP S 0 M 175-156 COVER RESPONSIBILITY LEGEND 7 CAST STONE 1 R 1 (MATCH 175-314 PERIMETER FILLER 3 A 3 SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR 2'- 10" AFF (VIF) ADJACENT) 1 1C T/O SILL TOP 128-200 SPLINE SCREW SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS BLOCKING AS REQUIREDBRICK NATURAL - STORE #:8123 MATCH TO EXISTING GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY GLAZING DETAIL @ MULLION 6" METAL STUDS (MATCH PROJECT #:25450-048 GENERAL CONTRACTOR 3 ADJACENT FRAMING) Scale: 3" = 1'-0" TIE BRACES ISSUE DATE: 11/1/17 NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS SILL SEALER UNDER DESIGNER: LISA MACEDA DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTIONBOTTOM STUD R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM TOP MULLION FLASHING & WEEPS EXISTING SLAB CHECKED BY: CONCRETE SIDEWALK Revision Schedule HEAD RevDateByDescription 1"INFILL C:\\Users\\zach.scholl\\Documents\\Starbucks_131st EXTERIORINTERIOR EXISTING FOOTING 175-001 PERIMETER MULLION 175-156 COVER SHEET TITLE: 175-314 PERIMETER FILLER 128-200 SPLINE SCREW DOOR AND WINDOW 5" SCHEDULES NTS SCALE: GLAZING DETAIL @ TOPWALL SECTION AT GLAZING SHEET NUMBER: 45 Scale: 3" = 1'-0"Scale: 3/4" = 1'-0" I-1103.1 10/31/2017 6:20:41 PM 1' - 9" PENETRATION PLAN NOTES EQ.EQ A.ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED ALL CONDUIT STUB UPS TO WALL LOCATIONS (SHOWN AS OUTLINES ON THIS PLAN). BE WITHIN THIS BOUNDARY 1' - 6" DIMENSION DATUM POINT REFER TO FLOOR PLAN FOR WALL PLACEMENT. ALL CONDUIT STUB-UPS TO EQEQ 7" EQ. DIMENSION DATUM POINT BE WITHIN THIS BOUNDARY B.FLOOR SINK / DRAIN: REFER TO CUT SHEETS ALL CONDUIT STUB FOR COMPONENT SPECIFICATIONS AND CUTOUT 3" UPS TO BE WITHIN THIS EQ.EQ. EQ REQUIREMENTS. DIMENSION BOUNDARY DATUM POINT 3" C.NEW WASTE LINE PENETRATIONS: REFER TO PLUMBING EQ R PLANS FOR INDIVIDUAL LINE SPECIFICATIONS. PENETRATION EQ. 3/4" LAN CONDUIT TO POS / SAFE TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED EQ C 2017 STARBUCKS COFFEE COMPANY PER CONDITIONS. 3" 3/4" ISOLATED GROUND 3/4" POWER CONDUIT FROM POWER CONDUIT 3/4" POWER CONDUIT TO PANEL FOR PASTRY CASE D.LOCATION OF WALL OUTLET AT 18 IN AFF. COORDINATE ELECTRICAL PANEL EQ. STARBUCKS COFFEE CWF STUB UP 3/4" POWER FUTURE LOCATIONS WITH STARBUCKS CONSTRUCTION MANAGER. 3/4" LAN CONDUIT 1/2" PHONE TO MANAGERS DESK REFER TO ELECTRICAL SHEETS FOR MORE INFORMATION. HW STUB UP 1/2" SECURITY TO COMPANY 1/2" DATA TO MANAGERS DESK 3/4" ISOLATED GROUND POWER CONDUITMANAGERS DESK CW STUB UP E.TOILET FLOOR PENETRATION: REFER TO CUT SHEETS FOR 2401 UTAH AVENUE SOUTH STUB-UP LOCATION RELATIVE TO FINISHED WALL. SEATTLE, WASHINGTON 98134 (206) 318-1575 F.FLOOR PENETRATIONS AT MOP SINK: REFER TO PLUMBING PLANS FOR INDIVIDUAL LINE SPECIFICATION. STUB UPS - FRONT BARSTUB UPS - DOUBLE POS/SAFESTUB UPS - ESPRESSO HAND-OFF THESE DRAWINGS AND SPECIFICATIONS ARE 234 Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0" CONFIDENTIAL AND SHALL REMAIN THE SOLE G.WALL OUTLET COVER PLATE FINISH TO MATCH WITH PROPERTY OF STARBUCKS CORPORATION, ADJACENT FINISH. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE H.LOCATION OF DUPLEX OUTLET AT 12 IN AFF. COORDINATE REPRODUCED (IN WHOLE OR IN PART), SHARED 10' - 10" LOCATIONS WITH STARBUCKS CM. REFER TO ELECTRICAL WITH THIRD PARTIES OR USED IN ANY MANNER SHEETS FOR MORE INFORMATION. ON OTHER PROJECTS OR EXTENSIONS TO THIS 6' - 5 1/2" PROJECT WITHOUT THE PRIOR WRITTEN I.SLAB DEPRESSION FOR WALK-OFF MAT. CONSENT OF STARBUCKS CORPORATION. 1' - 6 1/2" 5' - 9"8' - 4"5' - 3"5' - 8 1/2"8' - 8"5' - 9"2' - 10 1/2" THESE DRAWINGS AND SPECIFICATIONS ARE J.LOCATION OF DUPLEX OUTLET AT 46 IN AFF. COORDINATE INTENDED TO EXPRESS DESIGN INTENT FOR A CLOCATIONS WITH STARBUCKS CM. REFER TO ELECTRICAL H GDGDGD H PROTOTYPICAL STARBUCKS STORE (WHICH IS SHEETS FOR MORE INFORMATION. SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. K.LOCATION OF DUPLEX OUTLET AT 42" IN AFF. COORDINATE NEITHER PARTY SHALL HAVE ANY OBLIGATION LOCATIONS WITH STARBUCKS CM. REFER TO ELECTRICAL NOR LIABILITY TO THE OTHER (EXCEPT STATED MEN SHEETS FOR MORE INFORMATION. BABOVE) UNTIL A WRITTEN AGREEMENT IS RESTROOM FULLYEXECUTEDBYBOTHPARTIES 3 1/2" L.FLOOR OUTLET. SEE ELECTRICAL DRAWINGS FOR MORE A INFORMATION. STARBUCKS TEMPLATE VERSION i2017.08.25 M.LOCATION OF DUPLEX OUTLET AT 7'-2" AFF. COORDINATE LOCATIONS WITH STARBUCKS CM. REFER TO ELECTRICAL E SHEETS FOR MORE INFORMATION. Design Forum N.REMOVE EXISTING FLOOR DRAINS/SINKS AND CAP. 13' - 4"20' - 1" DG Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman HALLWAY Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 A Design Forum DG E PENETRATION SYMBOL LEGEND 3 3 I-5012 I-5012 Engineering FLOOR SINK B 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE LL 6' - 2" Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 FLOOR PENETRATION CAFE/SEATING WOMEN C PLUMBING PENETRATION AREA AN A RESTROOM 3' - 4" DG 15' - 10" ELECTRICAL PENETRATION AREA 2' - 0 1/2" L L 9' - 1" DATUM POINT WALL OUTLET RETAIL 4' - 0" 11/01/1709/01/17 DRAIN FLOOR SINK ROUND K 6' - 2" 17' - 6" A 15' - 5" I 3 10' - 1" I-1104 3' - 4" 41' - 10" L 14' - 4" 40' - 8 1/2" 4 2 L 4' - 8" I-1104I-1104 Y E B TOP SET PER W LOCAL CODE D BEVERAGE K 35' - 1 1/4" CAULK JOINT PREP. P L AN L TILE FLOOR E 3 31' - 1" L WORKROOM 3 Z E 0 29' - 9 1/2" BB AN A 26' - 7"D6 WATERPROOF MEMBRANE, 4 L 17' - 7" H 26' - 8 1/2" TYP. GC TO COORDINATE DG E N INSTALLATION WITH 14' - 0" B I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 23' - 9" Z CONSTRUCTION MANAGER & , 10' - 0" B A L CAST IRON FLANGED RECEPTOR T H E "SANI-CEPTOR 3100-C" C S 0 M CONCRETE SUBFLOOR 7 1 R 17' - 0" 1 NO-HUB CONNECTION 3 A 16' - 5 1/2" 3 14' - 11" 1 1C 3" TALL PIECE B C 6' - 3" STORE #:8123 M B F 9' - 5" J PROJECT #:25450-048 FLOOR SINK DETAIL 8' - 9" 8' - 2"BB 5 ISSUE DATE: 11/1/17 7' - 1" Scale: 1/4" = 1'-0" DESIGNER: LISA MACEDA 5' - 8" 5' - 7" R 5' - 1" 3' - 8" LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 3' - 1" CHECKED BY: 1' - 6" 1' - 4 1/4" Revision Schedule DG RevDateByDescription 14' - 0" 2' - 1" 16' - 4" DATUM POINT DATUM POINT 8' - 6" C:\\Users\\zach.scholl\\Documents\\Starbucks_131st WORKROOM BEVERAGE PREP 21' - 1 1/2" 22' - 3" 24' - 11" SHEET TITLE: 30' - 4" PENETRATION PLAN 36' - 6" AS SHOWN SCALE: PENETRATION PLAN SHEET NUMBER: 1 N Scale: 1/4" = 1'-0" 02'4'8' I-1104 10/31/2017 6:20:45 PM Scale: 1/4" = 1'-0" FURNITURE, FIXTURE AND SHEET NOTES EQUIPMENT PLAN NOTES 1.GENERAL CONTRACTOR TO REVERSE DOOR HINGE A.GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL ON UNDER COUNTER REFRIGERATOR TO LEFT-HAND REFRIGERATION CONTRACTOR TO CONDUCT INITIAL FOOD SWING, AS SHOWN. CASE START-UP AND TESTING. FOR LIST OF APPROVED START UP CONTRACTORS, CONTACT PROJECT 2.INSTALL MERCH BAYS AS INDICATED. CONSTRUCTION REPRESENTATIVE. SECURE LOCKERS TO WALL PER MFGS. 3. B.THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER RECOMMENDATIONS. SYSTEM UNLESS OTHERWISE NOTED. R RELOCATED NEWSPAPER STAND. 4. C.ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL C 2017 STARBUCKS COFFEE COMPANY SANITATION FOUNDATION STANDARDS OR EQUIVALENT. 5.INSTALL MERCH BASKETS AS INDICATED. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, D. STARBUCKS COFFEE 6.REFER TO ENLARGED RESTROOM PLAN AND EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE ELEVATIONS FOR NEW PLUMBING FIXTURE AND AS PLACES FOR ACCUMULATION OF DUST, DIRT AND COMPANY ACCESSORIES LOCATIONS AND MOUNTING HEIGHT. DEBRIS. 2401 UTAH AVENUE SOUTH 7.LOCATION OF CUP DISPENSERS. E.WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. SEATTLE, WASHINGTON 98134 INSTALLATION AT STORE OPENING TO BE VERIFIED BY (206) 318-1575 SEE CASEWORK PLAN FOR LOCATION OF HANDSINK. 8. STARBUCKS CONSTRUCTION REPRESENTATIVE. THESE DRAWINGS AND SPECIFICATIONS ARE 9.DO NOT CAULK TRASH RINGS TO COUNTERTOP. F.EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE CONFIDENTIAL AND SHALL REMAIN THE SOLE TOWEL AND SOAP DISPENSER AND ALL HAND SINKS TO PROPERTY OF STARBUCKS CORPORATION, 10.RELOCATED BLENDERS. HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 11.RELOCATED POS EQUIPMENT. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING G. REPRODUCED (IN WHOLE OR IN PART), SHARED DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO WITH THIRD PARTIES OR USED IN ANY MANNER 12.RELOCATED MASTRENAS. THE ELECTRICAL DESIGN PLAN. ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN 13. RELOCATED BREWER AND SHUTTLES. CONFIRM ALL NECESSARY CLEARANCES PER PRODUCT CUT H. CONSENT OF STARBUCKS CORPORATION. SHEET REQUIREMENTS FOR ALL EQUIPMENT (E.G. ICE THESE DRAWINGS AND SPECIFICATIONS ARE 14.RELOCATED METRO RACK. MACHINE). INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS 15.RELOCATED SCALE AND GRINDER. 14350 F SUBJECT TO CHANGE AT ANYTIME) AND DO 11115 E (4) 1011616520 PF NOT REFLECT ACTUAL SITE CONDITIONS. 16.RELOCATED MOBILE ORDER PAY CUP LABELER. NEITHER PARTY SHALL HAVE ANY OBLIGATION (2)(4)(4)(4)(4) E10384P10597F17984F17644F18106F18318GX1403F17877 10179 E NOTE: NOR LIABILITY TO THE OTHER (EXCEPT STATED 17.RELOCATED MOBILE ORDER PAY PRINTER. ABOVE) UNTIL A WRITTEN AGREEMENT IS SEE SHEET I-1105.1 FOR DATA DEVICE SCHEDULE - "A" FULLYEXECUTEDBYBOTHPARTIES 18.MOBILE ORDER PAY CUP LABELER. SEE SHEET I-1105.1 FOR SPECIALITY EQUIPMENT SCHEDULE -"E" 19.LOCATION OF ALL SWITCHING. STARBUCKS TEMPLATE VERSION i2017.08.25 (2) F17984 SEE SHEET I-1105.1 FOR FURNITURE SCHEDULE - "F" X0100 P 20.RELOCATED SECURITY SAFE AND BASE. MEN (4) F16520 Design Forum SEE SHEET I-1105.1 FOR GRAPHICS SCHEDULE - "G" RESTROOM 21.RELOCATED 10-COMP LOCKER. (4) 17644 X0101F P 6 X0102 P SEE SHEET I-1105.1 FOR MECHANICAL SCHEDULE - "M" (4) F18106 22.EXISTING ELECTRICAL PANELS TO REMAIN. Architects Inc. 1009910862 EE 10756 F 700 W. Pete Rose Way, Suite 460Donald J. Rethman SEE SHEET I-1105.1 FOR PLUMBING SCHEDULE - "P" 23.RELOCATED 2-DOOR REFRIGERATOR. 1017210859 Cincinnati, OH 45203Architect In Charge EE 10' - 7" GX1402 Tel: (513) 421-2210License: AR19700147 E10769 SEE SHEET I-1105.1 FOR SITE SCHEDULE - "Y" 24.RELOCATED 2-DOOR FREEZER. 13' - 4"16' - 1" 10753 G 22 25.EXISTING PATIO RAILING TO REMAIN. Design Forum HALLWAY 26.RELOCATED WATER FILTRATION SYSTEM. Engineering (2) F16520 27.LOCATION OF FUTURE PREP STATION. (2) F17645 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE G10753 Cincinnati, OH 45203Professional Engineer 28.RELOCATED WORKROOM HAND SINK. License: PE10504904 Tel: (513) 421-2210 (8) 18106 F (2) F18318 29.RELOCATED FIRE EXTINGUISHER. E10099E10859 F10756 PX0101 1017210862 EE 30.RELOCATED 3-COMP SINK. PX0102 10769 E ADAADA X1401(2) GF18406 P10597 31.RELOCATED DATA AND COMMUNICATION DEVICES. PX0100 (16) F18106 10116 P WOMEN X1305 (2)F 17877 F 14350 F 32.RELOCATED 1-DOOR UNDERCOUNTER REFRIGERATOR. 3 RESTROOM 10384 E E11115 I-5013 CAFE/SEATING 6 E10179 21 ADA 11/01/1709/01/17 (8) F18112 2 (3) E10416 5 RETAIL (4) F17645 14 (3) E10462E10293 (4) 12194 F 14 11104 E 4 L 2 L 3 Y (2)(2) E10091P10294 E F18106 (4)(2)(2)(2) 10791103961087410726 EEPP W D 24 (4)(2)(2)(2) 10855108581021511003 K EEPP 15699 E 22 P (2)(2)(2)(2) E13584E13330P10153P12808 L L E 3 E18029 L 3 Z 11 E 10813 E 0 16238 E 1212 (2) E10527 A D6 4 10110 E 9 E17588 L H P10294 E N E17255 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt(2) A10075 BEVERAGE 32 10726 P Z & 2016, 32 Y10042 23 18 A PREP. L (18) F17853 10152EX1501(3) P 10820 F 7 ADA T 10075 A H 10267 EE10267 E P10726P10294 (2)1261817572 EP 14523 E (2)(7) F17341F17340 S 0 1756510215 PP M E10344 (2) P17650P10294 18744 A (4) F18106 1 15 7 1 10 1763217564 1 PP 19 R (2) P17569P10726 1 3 A 3 8 29 31 FX1305 1 1C 105971725 P 10123 F 28 STORE #:8123 PATIO 10605 F 11115(3) E12147 Y F10809 10992(3) E16628 Y PROJECT #:25450-048 (2)12407 E 18 ADA 1' - 0" 18106 F ISSUE DATE: 11/1/17 10075 A 7 1108332 E DESIGNER: LISA MACEDA WORKROOM E17567 R LEED AP: 27 E17568 3212 PRODUCTION DESIGNER: PETER CHEETHAM E17264 P10294 (2) 110031874310312 PPEP10294 1330 26 CHECKED BY: E18159 10726 (2)P 102941087410856 PPEP10726 13326 E 17851 P 11 P10726P10153 PX0100 (2) E10149 Revision Schedule 14141410182 E 14 10527 E RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st (2) E13682P10995E10416 (2) M10894P10153P11003F16520 (2) P10922E10462 (4) F18106 P10215P12808F17645 (2) 13149 P SHEET TITLE: 10874 P E10698 FF AND E PLAN FURNITURE, FIXTURES AND EQUIPMENT PLAN 1 N 1/4" = 1'-0" SCALE: Scale: 1/4" = 1'-0" 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" I-1105 10/31/2017 6:20:57 PM DATA DEVICE SCHEDULE - "A" SPECIALTY EQUIPMENT SCHEDULE - "E"GRAPHICS AND ARTWORK SCHEDULE - "G" DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS AUDIO VISUAL COOLINGGRAPHICS - ARTWORK 100172SPEAKER SURFACE MOUNTED BLACKSB-GC 101101FRIDGE REACH IN 1 DOOR RH - 29IN 735MMSB-GCX1401117657; FRAMED WITH NO MAT; PAPER TYPE:SB-GCSEE ELEVATION 2/I-2101; BY GFX DATA PAPER 1; FRAME: LARSON-JUHL N11719 102672FRIDGE UNDERCOUNTER 1 DOOR - 27INSB-GC 187441EQUIPMENT RACK WITH LOCK - 24IN 610MMSB-GC FROSTED WALNUT 1/4" SPACER; OVERALL 685MM POINT OF SALE SIZE: 45" W X 45" H; METAL FRAME 110831FRIDGE REACH IN 2 DOOR - 51X35INSB-GC THICKNESS: 1/4" 100754CUP LABELERSB-GC 1295X890MM X1402117659; FRAMED WITH NO MAT; PAPER TYPE:SB-GCSEE ELEVATION 2/I-2101; BY GFX R 126182FRIDGE UNDERCOUNTER 1 DOOR WITHSB-GC PAPER 1; FRAME: LARSON-JUHL N11719 SHELF - 27IN 685MM FROSTED WALNUT 1/4" SPACER; OVERALL C 2017 STARBUCKS COFFEE COMPANY 136821FREEZER REACH IN 2 DOOR - 54IN 1370MMSB-GC SIZE: 45" W X 45" H; METAL FRAME DATA DEVICE SCHEDULE - EXISTING 175671WATER CHILLERSB-GC THICKNESS: 1/4" EQUIPMENT STARBUCKS COFFEE X1403117681; PRINTED ON DREAMSCAPE CANVASSB-GCSEE ELEVATION: 3/I-2101; BY GFX DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 103122BREWER SOFT HEAT WARMING STANDSB-GC AS WALLCOVERING; BACKGROUND: WHITE; AUDIO VISUAL COMPANY SINGLE ART: BLACK; OVERALL SIZE: 45' -2" W X 9'- 3" 100051MUSIC SYSTEMEXIST H 108562BREWER SERVER SOFT HEATSB-GC 2401 UTAH AVENUE SOUTH 100103MONITOR - 15IN 380MMEXIST X14041CUSTOM COMMUNITY BOARD; FRAMEDSB-GCSEE ELEVATION: 1/I-2101; BY GFX 124072OVEN TURBOCHEF NEXT GENERATIONSB-GC SEATTLE, WASHINGTON 98134 MAGNETIC COMMUNITY BOARD; FRAME: 100135DT QUEUE CAMERAEXIST 125083BLENDER QUIET MODEL ON COUNTERSB-GC (206) 318-1575 413677, NATURAL MAPLE; 100174SPEAKER SURFACE MOUNTED BLACKEXIST FOOD CASE OVERALL SIZE: 3' - 0" W X 4' - 0" H 100761AMPLIFIER - 14IN 355MMEXIST THESE DRAWINGS AND SPECIFICATIONS ARE 162381FOOD CASE - ZEPHYR - 66IN 1675MMSB-GC GRAPHICS - INTERIOR MENU DATA CONFIDENTIAL AND SHALL REMAIN THE SOLE ICE 128375MENU BOARD - 1 FRONT PANEL INSERTSB-GC PROPERTY OF STARBUCKS CORPORATION, 100002PHONE 1 LINEEXIST 103441ICE - BIN DROP IN 90LB 40KGSB-GC STYLE WHICH IS THE OWNER OF THE COPYRIGHT IN 100021COMPUTER MANAGER WORKSTATIONEXIST 105273ICE - BIN DROP IN 45LB 20KGSB-GC 128381MENU BOARD - DAILY OFFERINGSB-GC THIS WORK. THEY SHALL NOT BE 100071PRINTER MANAGER WORKSTATIONEXIST 108131ICE - MACHINE ICE1406HR REMOTE COOLEDSB-GC CHALKBOARD FRONT PANEL RECTANGULAR REPRODUCED (IN WHOLE OR IN PART), SHARED 100191WIDE AREA NETWORK HARDWAREEXIST 180291ICE - BIN B110SB-GCWITH THIRD PARTIES OR USED IN ANY MANNER 128396MENU BOARD - UNIVERSAL MOUNTINGSB-GC POINT OF SALE ON OTHER PROJECTS OR EXTENSIONS TO THIS HARDWARE FOR FRONT PANELS NITRO PROJECT WITHOUT THE PRIOR WRITTEN 100032POS - REGISTER WITH FULL SIZE CASHEXIST GRAPHICS - OTHER 145231TANK MOUNTING BRACKET SINGLESB-GC CONSENT OF STARBUCKS CORPORATION. DRAWER 107532RESTROOM SIGN SET ACCESSIBLESB-GC 175881KEG DISPENSING SYSTEM - 27IN 685MM -SB-GCKIT INCLUDES UNDERCOUNTER THESE DRAWINGS AND SPECIFICATIONS ARE 100082POS - REGISTER WITH COMPACT CASHEXIST WITH NONPLUMBED DRIP TRAYFRIDGE, TAPS, TRAY, AND TUBING 115261BULLETIN BOARD - 36X24IN 915X610MMSB-GC INTENDED TO EXPRESS DESIGN INTENT FOR A DRAWER X15013KEGS FOR NITROSB-GCVD: DELFIELD; 126801EDUCATION DISK - MUGSSB-GCDUGGAL PROTOTYPICAL STARBUCKS STORE (WHICH IS 100144POS PRINTEREXIST 3 IN BOH - 3 IN FOH SUBJECT TO CHANGE AT ANYTIME) AND DO 126881EDUCATION DISK RECYCLESB-GCDUGGAL 100221MONEY COUNTEREXIST OTHER NOT REFLECT ACTUAL SITE CONDITIONS. 126892EDUCATION DISK - HAND DRYERSB-GCDUGGAL 100296POS BANKEXIST NEITHER PARTY SHALL HAVE ANY OBLIGATION 100912CUP DISPENSER TALL HOT VERTICALSB-GC 142981EDUCATION DISK - GROUNDS FOR YOURSB-GCDUGGAL NOR LIABILITY TO THE OTHER (EXCEPT STATED 100752CUP LABELEREXIST 100992RESTROOM TOILET PAPER HOLDERSB-GC GARDEN ABOVE) UNTIL A WRITTEN AGREEMENT IS SECURITY 101722RESTROOM SEAT COVER DISPENSERSB-GC 144032EDUCATION DISK - WATER LOW FLOWSB-GCDUGGAL FULLYEXECUTEDBYBOTHPARTIES 100041ALARM SYSTEMEXIST 101792HAND DRYER SURFACE MOUNTEDSB-GCWAREHOUSE 100281SAFE BASEEXIST 101821DT ESPRESSO TOPPING RAILSB-GC STARBUCKS TEMPLATE VERSION i2017.08.25 103842DIAPER CHANGING STATION HORIZONTALSB-GC PLUMBING FIXTURE SCHEDULE - "P" 103962CUP DISPENSER SHORT HOT VERTICALSB-GC 107692RESTROOM GRAB BAR VERTICAL - 18INSB-GC FURNITURE SCHEDULE - "F" Design Forum DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 455MM DRAIN DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 107914CUP DISPENSER GRANDE VENTI COLDSB-GC 1029418DRAIN - FLOOR SINK SQUARE - 12IN 305MMSB-GC VERTICAL Architects Inc. CHAIR 1072610DRAIN - GRATE HALF SQUARE - 12IN 305MMSB-GC 108554CUP DISPENSER GRANDE VENTI HOTSB-GC 700 W. Pete Rose Way, Suite 460Donald J. Rethman 1785318CHAIR - CAFE ANGLED BACK WITH WOVENSB-GC Cincinnati, OH 45203Architect In Charge X01003FLOOR DRAIN 6"GC-GCZURN ZN415B VERTICAL SEAT - BLACK AND GREY ROPE MT0028 F0195 Tel: (513) 421-2210License: AR19700147 EQUIPMENT 108582CUP DISPENSER TALL COLD VERTICALSB-GC 178776CHAIR - STOOL 16IN 405MM TURNED WOOD 1SB-GC 175641BLENDER PITCHER RINSER WITH SENSORSB-GC - WHITE OAK WD0073 108592RESTROOM GRAB BAR - 48IN 1220MMSB-GC FAUCET 179844BANQUETTE - FRAMED CUSHION - 69INSB-GC108622RESTROOM GRAB BAR - 36IN 915MMSB-GC Design Forum 101521FAUCET - DOUBLE LABORATORY WITH BENTSB-GC 1755MM - WARM BROWN NATURAL F0055 109921PAPER TOWEL DISPENSER HALF SIZE -SB-GC RISER SPOUT TRANSLUCENT GRAY 1810642CHAIR - CAFE JULIE - WHITE OAK WD0073SB-GC Engineering 101533FAUCET - WATER TOWER - 12IN 305MMSB-GC 181128CHAIR - STOOL BAR HEIGHT JULIE - WHITESB-GC111153SOAP DISPENSER SINK MOUNTEDSB-GC 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 102154FAUCET - DOUBLE LABORATORY WITH SWINGSB-GC OAK WD0073 133302MOBILE CUP DISPENSER CADDYSB-GC Cincinnati, OH 45203Professional Engineer SPOUT 183186CHAIR - LOUNGE ARMLESS TUFTED CUSHIONSB-GC License: PE10504904 135842CUP DISPENSER TRENTA COLD VERTICALSB-GC Tel: (513) 421-2210 WITH METAL FRAME - WARM BROWN105973FAUCET - SINGLE HANDLESB-GC STORAGE NATURAL F0055 108743FAUCET - HOT WATER DISPENSERSB-GC 101492DT LID SHELF WALL MOUNTEDSB-GC GOOSENECK DESK 10293110 COMP LOCKEREXIST 109221FAUCET - MOP SINK WALL MOUNTED 101231DESK - MANAGERS WORKSTATION -SB-GC 104165WORKROOM WIRE SHELVINGSB-GC 60X30X30IN 1525X760X760MM - ALMOND 110033FAUCET - DIPPERWELLSB-GC 104625WORKROOM WIRE SHELVING POSTSSB-GC LAMINATE 175691FAUCET - WARE RINSER IN COUNTER -SB-GC 106981MOP RACK WITH 3 HOLDERSSB-GC 106051DESK - MANAGERS WORKSTATIONSB-GC 24X9IN 600X235MM 11104110 COMP LOCKER BASEEXIST KEYBOARD TRAY - BLACK PLASTIC 175721FAUCET - TAP SINGLE HANDLESB-GC 133261PRE WASH STATION - 36IN 915MMSB-GC 108091DESK - MANAGERS WORKSTATION SHELVESSB-GC FILTER WALL MOUNTED - ALMOND LAMINATE 156991PARTNER WORK CENTERSB-GC 131491FILTER - PRESSURE GAUGE MIRROR 172551PASTRY TRAY CART - 60IN 1525MMSB-GC OTHER 143502MIRROR - RESTROOM ANGLED- 18X36INSB-GC 172641ROLLING PASTRY TRAY THAW RACK -SB-GC 11/01/1709/01/17 178511CHILLED WATER CONDUIT - 60FT 1829CMSB-GC 455X915MM 20X26IN 510X660MM SINK OTHER 175681BRACKET FOR WATER CHILLERSB-GC 101162SINK - RESTROOM WALL MOUNTEDSB-GC 107562COAT HOOK 2 PRONGSB-GC@ RESTROOMS 181591WORKROOM SHELVING WITH TANK BRACKETSB-GC 105491SINK - RINSE DROP IN SST - 12X20INSB-GC - 36IN 915MM 108201COAT HOOK STRIP - 46IN 1170MMSB-GC 305X510MM L TABLE 109951SINK - MOP - 24X24IN 610X610MM L 121944TABLE - BASE FIXED DOME ACCENT ANDSB-GC Y 128071SINK - UTENSIL RINSE WITH GRATE SST - LH -SB-GC GUSSETS - 42IN 1065MM - HOT ROLLED E 14X20IN 355X510MM STEEL MT0011 W D 128082SINK - UTENSIL RINSE WITH GRATE SST - RH -SB-GC 1652012TABLE - BASE CAFE DOME ACCENT - 18X28INSB-GC K 14X20IN 355X510MM 455X710MM - HOT ROLLED STEEL MT0011 P L 175651SINK - RINSE WITH DRAINBOARD - 15X27INSB-GC 173407TABLE - CAFE METAL PEDESTAL BASESB-GC L 380X685MM SPECIALTY EQUIPMENT SCHEDULE - EXISTING E 3 SQUARE - 24IN 610MM - BLACK MT0028 L 176321SINK - STACKED DRAINBOARD - 15IN 380MMSB-GC 3 Z 173412TABLE - ACCESSIBLE METAL WITH TAPEREDSB-GC E DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 0 176501SINK - DRAIN TRAY - 9X6IN 230X150MMSB-GC LEGS - 36X24IN 915X610MM - BLACK MT0028 A D6 COOLING 187431SINK - PREP STATION - 36X24IN 915X610MM 176448TABLE - TOP ROUND - 24IN 610MM - WHITESB-GC 4 102673FRIDGE UNDERCOUNTER 1 DOOR - 27INEXIST L TOILET OAK WD0073 H 685MM E N X01012TOILET - TANKLESS EFFICIENT SINGLE FLUSHGC-GCAMERICAN STANDARD 3461.001 176458TABLE - TOP SQUARE - 24IN 610MM - WHITESB-GC I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 110831FRIDGE REACH IN 2 DOOR - 51X35INEXIST Z OAK WD0073& X01022TOILET - FLUSH VALVE AUTOMATICGC-GCAMERICAN STANDARD 6047.111 (1.1 , 1295X890MM A EFFICIENT SINGLE FLUSHGPF) L 184062TABLE - COMMUNITY CAFE HEIGHT ANGLESB-GC 126181FRIDGE UNDERCOUNTER 1 DOOR WITHEXIST T H BASE - 10 SEAT NARROW - WITH POWER E SHELF - 27IN 685MM WHITE OAK WD0073 S 0 M 136821FREEZER REACH IN 2 DOOR - 54IN 1370MMEXIST PLUMBING FIXTURE SCHEDULE - EXISTING X13052CUSTOM - ADA TABLE - ACCESSIBLE WITHSB-GCSEE DETAIL: 3/I-5013 7 1 R EQUIPMENT NARROW METAL FRAME - WD0049 1 3 A DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 103121BREWER SOFT HEAT WARMING STANDEXIST 3 WINDOW TREATMENT 1 1C SINGLE FAUCET 127169ROLLER SHADE - CHARCOAL WOVEN F0049SB-GCBLIND EXPRESS 107462BREWER DUAL SOFT HEATEXIST (1) 1'-3" LENGTH 104471FAUCET - PRE RINSE SPRAYER WALLEXIST (1) 1'-5" LENGTH MOUNTED 108081GRINDER DITTING KR1203EXIST STORE #:8123 (2) 2'-5" LENGTH 108041FAUCET - PRE RINSE SWING SPOUTEXIST 108565BREWER SERVER SOFT HEATEXIST PROJECT #:25450-048 (2) 3'-0" LENGTH 135881FAUCET - HAND SINK WALL MOUNTEDEXIST 110701DISHWASHER SANITIZEREXIST (4) 4'-7" LENGTH ISSUE DATE: 11/1/17 FILTER 125082BLENDER QUIET MODEL ON COUNTEREXIST DESIGNER: X14051CUSTOM ROLLER SHADES - CHARCOALSB-GCFIT TO CURVATURE OF WINDOW. SEELISA MACEDA 125011FILTER - RO SYSTEM 600GPDEXIST 126943ESPRESSO MACHINE MASTRENAEXIST R WOVEN F0049ELEVATION 1/I-2101LEED AP: 125071FILTER - RO SYSTEM 40GAL STORAGE TANKEXIST OTHER PRODUCTION DESIGNER: PETER CHEETHAM X14061CUSTOM ROLLER SHADES - CHARCOALSB-GCFIT TO CURVATURE OF WINDOW. SEE 128961FILTER - BRINE TANKEXIST CHECKED BY: 103141SCALE DIGITAL WITH ADJUSTABLE DISPLAYEXIST WOVEN F0049ELEVATION 1/I-2101 MOUNT 128992FILTER - POLY GLASS VESSELEXIST X14071CUSTOM ROLLER SHADES - CHARCOALSB-GCFIT TO CURVATURE OF WINDOW. SEE 105011FIRE EXTINGUISHEREXIST 130821FILTER - WATER SOFTENER TWINEXIST WOVEN F0049ELEVATION 1/I-2101 Revision Schedule 109471SOAP DISPENSER WALL MOUNTEDEXIST SINK 109771PAPER TOWEL DISPENSER FULL SIZE -EXIST RevDateByDescription 132641SINK - 3 COMP WORK SST - 93IN 2350MMEXIST TRANSLUCENT GRAY 146881SINK - HAND WITH SIDE SPLASH WALLEXIST STORAGE MOUNTED SST C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 102222WIRE SHELF GRID AT SINKEXIST MECHANICAL EQUIPMENT SCHEDULE - "M" 10293110 COMP LOCKEREXIST 104166WORKROOM WIRE SHELVINGEXIST DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS RESPONSIBILITY LEGEND 104626WORKROOM WIRE SHELVING POSTSEXIST FAN SHEET TITLE: 108381ROLLING WIRE CART FOR 3 COMP SINKEXIST SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR 108941FAN - DT AIR CURTAIN WITH HEATER - 48INSB-GCINCLUDED AS PART OF DT WINDOW 11104110 COMP LOCKER BASEEXIST 1220MMPACKAGE; BLACK TO MATCH FF AND E SCHEDULES SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS STOREFRONT 138341BASE - 24X18IN 610X455MMEXIST GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY NO SCALE SCALE: GENERAL CONTRACTOR SHEET NUMBER: NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION I-1105.1 10/31/2017 6:21:00 PM 9"14' - 9" 10 CUSTOM BACKBAR SHELF CX1014 555555 CASEWORK PLAN NOTES G12839G12839G12839G12839G12839G12839 1' - 10"6"2' - 5"2' - 5"9' - 3" G12837G12837G12837G12837G12837G12838 A. GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF A CBECBE DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, SITE DIMENSIONS, CASEWORK PLAN OR ACTUAL CASEWORK FIXTURES. ALL DIMENSIONS TO BE R 8" 1' - 1" TAKEN FROM DESIGNATED DATUM POINT. C 2017 STARBUCKS COFFEE COMPANY B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. GENERAL (2) 17580 CX1007F12839F12837C 17581 C CONTRACTOR TO CONFIRM CASEWORK DELIVERY DATE STARBUCKS COFFEE 1' - 3" WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS 373938 5 PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED COMPANY I-5012 DATE OF DELIVERY. 2401 UTAH AVENUE SOUTH C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK SEATTLE, WASHINGTON 98134 VENDOR TO SUPPLY CASEWORK LISTED IN CASEWORK (206) 318-1575 SCHEDULE, UNLESS OTHERWISE NOTED. 2' - 8" C17742 THESE DRAWINGS AND SPECIFICATIONS ARE D. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED C17829 CONFIDENTIAL AND SHALL REMAIN THE SOLE DT POS CUBBY LF BY CASEWORK VENDOR FOR COMPLETE INSTALLATION PROPERTY OF STARBUCKS CORPORATION, 63 INSTRUCTIONS. WHICH IS THE OWNER OF THE COPYRIGHT IN 1' - 11" SHE X1013 C THIS WORK. THEY SHALL NOT BE E. ALL CASEWORK BOX BASE UNITS SHALL BE SET ON 1/4" 2' - 0" REPRODUCED (IN WHOLE OR IN PART), SHARED (6MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY 10" WITH THIRD PARTIES OR USED IN ANY MANNER CASEWORK VENDOR. ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN F. SEE WALL FINISH PLAN FOR LOCATION, TAGGING, AND CONSENT OF STARBUCKS CORPORATION. FINISH SCHEDULES OF APPLIED WALL TREATMENTS. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT PROTOTYPICAL STARBUCKS STORE (WHICH IS LOCATIONS. UPPER CASEWORK PLAN SUBJECT TO CHANGE AT ANYTIME) AND DO 2 NOT REFLECT ACTUAL SITE CONDITIONS. Scale: 3/8" = 1'-0" H.REFER TO UPPER CABINET ATTACHMENT DESIGN DETAIL 02'4'6' NEITHER PARTY SHALL HAVE ANY OBLIGATION FOR INSTALLATION INFORMATION. NOR LIABILITY TO THE OTHER (EXCEPT STATED Scale: 3/8" = 1'-0" ABOVE) UNTIL A WRITTEN AGREEMENT IS I.POINT OF SALE AND HAND-OFF PLANE TO BE INSTALLED FULLYEXECUTEDBYBOTHPARTIES AT A MAXIMUM HEIGHT OF 2'-10" (860MM) A.F.F. STARBUCKS TEMPLATE VERSION i2017.08.25 SHEET NOTES Design Forum MEN 1.DO NOT CAULK TRASH RINGS TO COUNTERTOP. RESTROOM Architects Inc. 2. INSTALL CONDIMENT CART AS INDICATED. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 3.REFER TO CASEWORK DETAIL SHEETS FOR X1012 C ADDITIONAL INFORMATION. 3 4.INSTALL MERCH BAYS AS INDICATED. Design Forum 5.INSTALL MENU BOARDS AS INDICATED. CCX1014X1014 HALLWAY Engineering 6.INSTALL DT POS UPPER CUBBY AS INDICATED. 10 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE CAFE/SEATING Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 7.INSTALL CUSTOM BACKBAR SHELF AS INDICATED. 8.INSTALL WOODEN FRAMING ATTACHED TO SHELVING FOR MENU BOARDS. 9.INSTALL WOODEN BORDER ATTACHED TO WOODEN FRAMING FOR MENU BOARDS. 12 WOMEN 4 RESTROOM CX1215 (2) 15221 C 10.INSTALL SOLID WOOD PANEL AS INDICATED. 13191 C 11.INSTALL CORIAN PANEL VERTICALLY AT END OF WALL AS (2) C12363 INDICATED ON INTERIOR ELEVATION. 11/01/1709/01/17 12.INSTALL CORNER GUARD AS INDICATED. CASEWORK LEGEND L 5' - 9" 1 L 1 3 Y I-1106.1 MERCH BAYS INDICATES STAINLESS STEEL (SST) COUNTERTOP I-5010 I-5010 E W 311 D K INDICATES SOLID SURFACE (SS) COUNTERTOP CCX1012X1012 RETAIL P L L E 3 1 L 3 Z E 0 NOTE: A D6 4 EQ L SEE SHEET I-1105.1 FOR GRAPHICS SCHEDULE "G" T CART H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 4' - 8" SEE SHEET I-1106.1 FOR CASEWORK AND CASEWORK Z & , DIMEN FINISH SCHEDULE "C" A L EQ T H E CON BEVERAGE S 0 M 7 12236 C PREP.1 R 1 13374 C 3 A 3 4 C13377 1 1C I-5010 C13399 STORE #:8123 2 WORKROOM PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: 2 PRODUCTION DESIGNER: PETER CHEETHAM I-5010CX1012 CHECKED BY: 3 Revision Schedule 3 3 CX1013 RevDateByDescription CX1012 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 1 I-5013 1 SHEET TITLE: I-5012 CASEWORK PLAN CASEWORK PLAN 1 Scale: 1/4" = 1'-0" N AS SHOWN SCALE: 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" I-1106 10/31/2017 6:21:05 PM CASEWORK SCHEDULE - "C"CASEWORK SCHEDULE - "C" SHEET NOTES DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS CABINET181361COUNTERTOP - ESPRESSO CAP - 147INSB-GC 1.REFER TO CASEWORK DETAIL SHEETS FOR ADDITIONAL 3735MM 175743CABINET - SINK OR ICE - 15IN 380MMSB-GC INFORMATION. 181441COUNTERTOP - DT ESPRESSO - RF - 80INSB-GC 175751CABINET - SINK OR ICE - 20IN 510MMSB-GC 2030MM 2.CASEWORK VENDOR TO CUT HOLE IN BOTTOM OF 175802CABINET - CBE SHELF - 29X14IN 735X355MM -SB-GC X10031CUSTOM COUNTERTOP - NITRO AND HOP -SB-GCSEE DETAIL: 3/I-5010 CABINETS AS REQUIRED AT FLOOR SINKS AND FLAT BLACK MT0028 102IN 2590MM PROVIDE EDGING WHERE APPLICABLE. 175811CABINET - CBE SHELF - 22X10IN 560X255MM -SB-GC X10051CUSTOM COUNTERTOP - MOP - 31IN 787MMSB-GCSEE DETAIL: 4/I-5010 FLAT BLACK MT0028 3.LOCATION OF HANDSINK . X10061COUNTERTOP - DT POS - 118IN 2998MMSB-GCSEE DETAIL: 2/I-5010 177401CABINET - 30IN 760MMSB-GC R X10081COUNTERTOP - BACKSPLASH - VARIABLESB-GC 177414CABINET - 15IN 380MMSB-GC 4.INSTALL TRIM AS INDICATED. LENGTH C 2017 STARBUCKS COFFEE COMPANY 177421CABINET - DT POS UPPER CUBBY - 32INSB-GC DIEWALL 815MM 178311DIEWALL - POS - 82IN 2085MMSB-GC 177433CABINET - POS - 30IN 760MMSB-GC STARBUCKS COFFEE 181371DIEWALL - ESPRESSO - 147IN 3735MMSB-GC 177441CABINET - POS BRIDGE - 22IN 560MMSB-GC X10021CUSTOM DIEWALL - NITRO AND HOP - 101INSB-GCSEE DETAIL: 1/I-5010 177451CABINET - DRAWER - 15IN 380MMSB-GC COMPANY 2565MM 177473CABINET - TRASH - 15IN 380MMSB-GC 2401 UTAH AVENUE SOUTH FIT KIT 177542CABINET - ESPRESSO CUBBY - 18IN 455MMSB-GC SEATTLE, WASHINGTON 98134 178941FIT KIT - CABINET FILLER PANELSB-GC 181221CABINET - SINK OR ICE - 16IN 405MMSB-GC CASEWORK LEGEND (206) 318-1575 OTHER X10071CUSTOM BACKBAR SHELFSB-GCSEE DETAIL: 4/I-5012 111422CORBEL SUPPORT - 24IN 610MMSB-GC CAFE THESE DRAWINGS AND SPECIFICATIONS ARE 111553ESPRESSO MACHINE PUMP MOUNT - 10X10INSB-GC INDICATES STAINLESS STEEL (SST) COUNTERTOP 122361CONDIMENT CART SINGLE TOP SOLIDSB-GC CONFIDENTIAL AND SHALL REMAIN THE SOLE 255X255MM SURFACE PROPERTY OF STARBUCKS CORPORATION, 178291FRENCH CLEAT - VARIABLE LENGTHSB-GCDESIGNER TO VERIFY QUANTITY. WHICH IS THE OWNER OF THE COPYRIGHT IN 123632MERCH BAY UNIT BACK PANEL SOLIDSB-GCNOT PROVIDED BY CASEWORK INDICATES SOLID SURFACE (SS) COUNTERTOP PROVIDE OVERALL LENGTH THIS WORK. THEY SHALL NOT BE VENDOR REQUIRED : 2'- 6" REPRODUCED (IN WHOLE OR IN PART), SHARED 131911MERCH BAY UNIT END PANELS METAL MESHSB-GCNOT PROVIDED BY CASEWORK 181391ESPRESSO SHROUD - 147IN 3735MMSB-GC WITH THIRD PARTIES OR USED IN ANY MANNER VENDOR ON OTHER PROJECTS OR EXTENSIONS TO THIS 181453COUNTERTOP SUPPORT LEG 133741CONDIMENT CART SINGLE BASE FRAMESB-GCNOT PROVIDED BY CASEWORK PROJECT WITHOUT THE PRIOR WRITTEN X10125WINDOW SILL TOPSB-GCSEE DETAIL: 1/I-513 VENDOR CONSENT OF STARBUCKS CORPORATION. X10131DT WINDOW SILL TOPSB-GCSEE DETAIL: 1/I-5012 133771CONDIMENT CART SINGLE FINISH PANELSSB-GC THESE DRAWINGS AND SPECIFICATIONS ARE X10142CUSTOM WOODEN PORTALSB-GCSEE DETAIL: 14/I-5005 133991CONDIMENT CART SINGLE METAL TOPSB-GCNOT PROVIDED BY CASEWORK RESPONSIBILITY LEGEND INTENDED TO EXPRESS DESIGN INTENT FOR A ASSEMBLYVENDOR PANEL PROTOTYPICAL STARBUCKS STORE (WHICH IS SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR SUBJECT TO CHANGE AT ANYTIME) AND DO 152212MERCH BAY UNIT - DARK WARM BROWNSB-GCNOT PROVIDED BY CASEWORKX10011CUSTOM - FRONTBAR FINISH PANEL - 281INSB-GCSEE DETAIL: 1/I-5010 WD0001VENDOR7137MMNOT REFLECT ACTUAL SITE CONDITIONS. SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS NEITHER PARTY SHALL HAVE ANY OBLIGATION COUNTERTOPRAILING NOR LIABILITY TO THE OTHER (EXCEPT STATED 175771COUNTERTOP - CBE - RF - 111IN 2820MMSB-GCX12151CUSTOM CORNER TRIMGC-GCPROVIDED BY CASEWORK VENDOR GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY ABOVE) UNTIL A WRITTEN AGREEMENT IS (LOCATED @ CAFÉ): 177501COUNTERTOP - BREW - LF - 105IN 2665MMSB-GC GENERAL CONTRACTOR FULLYEXECUTEDBYBOTHPARTIES TOTAL OVERLAL LENGTH-10' - 0" IN 178091COUNTERTOP - HAND SINK WITH LOWSB-GC (26039MM) SPLASH STAINLESS - 15IN 380MM NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS STARBUCKS TEMPLATE VERSION i2017.08.25 DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION 178301COUNTERTOP - POS - 82IN 2085MMSB-GC 178381COUNTERTOP - WARMING - 60IN 1525MMSB-GC 181351COUNTERTOP - ESPRESSO WITH DUAL SINKSB-GC Design Forum AND ICE - 147IN 3735MM Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge 3' - 8"5' - 6"6' - 10"12' - 3"4' - 9" Tel: (513) 421-2210License: AR19700147 ZEPHYR PASTRY CASEPOSESPRESSOHOP/ NITRO 178311813618137 CCC Design Forum CW FINISH - NCS Engineering FINISH CODE LOCATIONDESCRIPTIONCOMMENTS 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer CABINETS License: PE10504904 Tel: (513) 421-2210 DT POS UPPER CUBBYPLASTIC LAMINATE - GRAPHITEPL0003 UNDERCOUNTER CABINET BACKBARPLASTIC LAMINATE - GRAPHITEPL0003 UNDERCOUNTER CABINET FRONTBARPLASTIC LAMINATE - GRAPHITEPL0003 CX1001 UNDERCOUNTER CABINET INTERIORPLASTIC LAMINATE - ALMOND 1 CAFE CONDIMENT CART TOPCOMPOSITE - WHITE WITH VEININGCP0002 X1002 C COUNTERTOPS - BACKBAR 1 (2) 111551813918135 CCC C17754 17743(2)1783017744 CCC DT POS ,DT ESPRESSO AND BACKBARCOMPOSITE - WHITE WITH VEININGCP0002 BEVERAGE COUNTERTOPS / NITRO CX1014 CX1003 PREP. 8' - 6" HAND SINK COUNTERTOPSTAINLESS STEEL - BRUSHED#4 BRUSHED 4 16GA SST 2 1HOP 11/01/1709/01/17 WARMING, BREW, AND CBECOMPOSITE - WHITE WITH VEININGCP0002 COUNTERTOP 4' - 6" 4' - 2" 3' - 6" COUNTERTOPS - FRONT BAR (2)(2) 18145175741774517750177471774017741175741812217577175751757417809 CCCCCCCCCCCCC 11142 C NITRO, HOP, ESPRESSO AND POSCOMPOSITE - WHITE WITH VEININGCP0002 3 COUNTER TOPS L FINISH PANELS 17741 C L CONDIMENT CART FINISH PANELSWOOD - VERTICAL SLAT WITH REVEAL -WD0073 Y E MAD100 W ESPRESSO, HOP, NITRO AND POSWOOD - VERTICAL SLAT WITH REVEAL -WD0073 D K (FRONT BAR) FINISH PANELSMAD100 EQEQ P L FINISH PANEL METAL TRIMHOT ROLLED STEELMT0011 L OTHER E 3 L C17741 D/T WINDOW SILLCOMPOSITE - WHITE WITH VEININGCP0002 2' - 7" 3 Z E 0 ENGINE SOFFIT WOOD PLANKWOOD - WHITE OAK - PLANKWD0073MAD100 A D6 MOP 2' - 7" ESPRESSO SHROUDCOMPOSITE - WHITE WITH VEININGCP0002 CX1005 4 L WOOD CLADDINGWOOD - VERTICAL SLAT WITH REVEAL -WD0073 H 1 MAD100 E N C17747 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L C17894 (2) C11155 T H E S 0 M CX1008 7 17754 C 1 R 1 1 3 A 3 17747 C 1 1C CX1006 SO 1 STORE #:8123 7' - 4" PROJECT #:25450-048 C18144 6' - 8"SPRES ISSUE DATE: 11/1/17 DT E DESIGNER: LISA MACEDA C18145 R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 1 CHECKED BY: CX1013 17743 C Revision Schedule RevDateByDescription 2 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st I-1106 5' - 0"8' - 9"9' - 3"1' - 3"1' - 3" SHEET TITLE: WARMING BREWCBE HS 3 CASEWORK SCHEDULE ENLARGED CASEWORK PLAN 1 N 1/2" = 1'-0" SCALE: Scale: 1/2" = 1'-0" 01'2'4' SHEET NUMBER: Scale: 1/2" = 1'-0" I-1106.1 10/31/2017 6:21:11 PM R C 2017 STARBUCKS COFFEE COMPANY STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES 3' - 8"5' - 6 1/4"6' - 10"12' - 3"4' - 8 3/4" STARBUCKS TEMPLATE VERSION i2017.08.25 PASTRY CASEPOS STATIONESPRESSO STATIONHAND-OFF/ NITRO Design Forum (R) ESPRESSO(R) 1DR U/C MACHINES (2)FRIDGE (2) Architects Inc. (R) SAFE AND (N) MAGIC (N) CUP (N) 45LB 700 W. Pete Rose Way, Suite 460Donald J. Rethman (N) PASTRY CASEBASE BELOWSINKLABELERS (2)ICE BIN Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 Design Forum Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 (N) PASTRY CART(R) POS (R) CUP (N) 45LB(N) MOBILE (N) MAGIC 8' - 5 3/4" EQUIPMENTSLABELERICE BINCUP CADDYSINK HAND-OFF/ NITRO 5' - 0"8' - 9"9' - 3"1' - 3"1' - 3 1/4" (N) NITRO TAP, U/C FRIDGE WARMING STATION BREW STATIONCBE HAND SINK AND BRACKET 11/01/1709/01/17 (R) SCALE(R) SHUTTLES (N) SHUTTLES (N) DEDICATED (N) 1DR U/C(N) NGO (N) DUMP AND AND AND (N) 90LB (N) 1DR U/C(N) WARE HAND SINK AND FRIDGE (2)OVEN (2)SINKGRINDERWARMERS (2)WARMERS (2)(R) BLENDERS (2)ICE BINFRIDGE (2)RINSER PAPER TOWELS L L Y E EQEQ W D (R) MOP K PRINTER P L 2' - 11 1/4" MOP 2' - 7" L E 3 (N) MOBILE L 3 Z CUP CADDY E 0 A D6 4 L H (N) CUP (R) DUAL(N) RINSE(N) COLD E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt LABELERBREWERSINKWATER TAP(N) CUP Z & , LABELER A L T H E S 0 M (R) 1DR U/C (R) ESPRESSO 7 1 R FRIDGE MACHINE 1 3 A 3 1 1C (R) 1DR U/C 6' - 8" DT POS FRIDGE 6' - 11 1/2" STORE #:8123 (R) POS (N) MAGIC PROJECT #:25450-048 DT ESPRESSO STATION EQUIPMENTS SINK ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: (N) 45LB PRODUCTION DESIGNER: PETER CHEETHAM ICE BIN CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: ENLARGED BAR PLAN - EQUIPMENT ENLARGED BAR PLAN - 1 N Scale: 1/2" = 1'-0" EQUIPMENT 1/2" = 1'-0" SCALE: 01'2'4' SHEET NUMBER: Scale: 1/2" = 1'-0" I-1106.2 10/31/2017 6:21:18 PM R C 2017 STARBUCKS COFFEE COMPANY STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 5' - 6"2' - 6"1' - 10"2' - 6"5' - 5"1' - 6"5' - 3"2"4' - 2" Design Forum Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 Design Forum (R) 1DR (R) 1DR U/C U/C Engineering FRIDGEFRIDGE 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 (N) 30IN (N) 22IN (N) 30IN (N) 18IN POS POS POS ESPRESSO CABINET (N) KEG BRIDGECABINETCUBBY DISPENSING SYSTEM (N) 15IN (N) 15IN (N) 15IN (N) 15IN (N) 16IN (N) 20IN (N) 15IN (N) CORBEL (N) 15IN SINK/ICE DRAWER(N) 15INTRASH(N) 30IN(N) 15INSINK/ICE SINK/ICE SINK/ICE SINK/ICE SUPPORT CABINET 10' - 6" CABINETCABINETCABINETCABINETCABINETCABINETCABINETCABINETCABINETCABINET EQEQ 11/01/1709/01/17 L (N) 1DR (N) 1DR (N) 1DR (N) 1DR (N) 15IN L U/C U/C U/C U/C CABINET Y FRIDGEFRIDGEFRIDGEFRIDGE E W D (N) 15IN K TRASH P L CABINET L E 3 L 3 Z (N) 18IN E 0 ESPRESSO A D6 1' - 6" CUBBY 4 L (R) 1DR H U/C E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt FRIDGE Z & , A (R) 1DR L T H U/C E FRIDGE S 0 M 7 (N) 15IN TRASH 1 R 1 CABINET 3 A 3 5' - 2" (N) SST LEG 1 1C STORE #:8123 (N) 30IN POS CABINET PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st ENLARGED BAR PLAN - CABINETS 1 N Scale: 1/2" = 1'-0" SHEET TITLE: ENLARGED BAR PLAN - 01'2'4' CABINETS Scale: 1/2" = 1'-0" 1/2" = 1'-0" SCALE: SHEET NUMBER: I-1106.3 10/31/2017 6:21:23 PM CEILING TREATMENT SCHEDULE - "U"BULB SCHEDULE - "L" SHEET NOTES REFLECTED CEILING PLAN NOTES DESIGN IDAREADESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS A.IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO 1.EXISTING 2' X 4' ACT CEILING TO REMAIN. PATCH AND REPAIR OTHERLAMP PROVIDE SEMI-RECESSED SPRINKLER HEADS WITH POLISHED CEILING AS REQUIRED FOR NEW WORK. 1051764 SFACT - WHITE - 2X2FT 61X61CMGC-GCARMSTRONG KITCHEN ZONE1451844LED PAR 30 850LM 2700K NFL - WHITESB-GC CHROME ESCUTCHEONS CENTERED IN ACOUSTICAL CEILING 1130224 SFACT - WHITE - 2X4FT 61X122CMGC-GCARMSTRONG KITCHEN ZONE TILE. IF PENDANT HEADS ARE REQUIRED IN GYPSUM SOFFIT EXTEND NEW ACT CEILING GRID. PROVIDE NEW FULL TILE 2. OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT. X1207265 SFACT - MATCH TO EXISTING - 24 X 48FTGC-GCARMSTRONG KITCHEN ZONEWHERE APPLICABLE. ALIGN NEW CEILING GRID WITH EXISTING. GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO 61X122CM STARBUCKS' CONSTRUCTION MANAGER FOR APPROVAL PRIOR 3.INSTALL NEW 2' X 4' CIRRUS PANEL CEILING AT CAFE AS X12081415 SFARMSTRONG - 2X4FT 61X122CM; CIRRUSGC-GC PAINT SCHEDULE TO INSTALLATION. INDICATED. SECOND LOOK: 511 WHITE; 6"X48" LINEAR R PLANK LOOK PANEL COLOR CODEDESCRIPTIONLRVRESP.COMMENTS B.GENERAL CONTRACTOR TO PROVIDE AND LOCATE 4.INSTALL NEW 2' X 2' ACT CEILING AS INDICATED. WOOD CLADDING SW6165SW - 616524GC-GCUSE PRIMER CP-1 C 2017 STARBUCKS COFFEE COMPANY SPRINKLERS PER LOCAL CODES. CONTACT STARBUCKS WD007336 SFWOOD - WHITE OAK WD0073 MAD100SB-GCWOOD CLADDING SW7005Paint - SW7005 PURE WHITE84GC-GCUSE PRIMER CP-1 CONSTRUCTION MANAGER IF DESIGN INTENT IS AFFECTED. 5.INSTALL NEW WOODEN SOFFIT AT BACKBAR AS INDICATED. SW9138SW - STARDEW43GC-GCUSE PRIMER CP-1 STARBUCKS COFFEE WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE C. 6.INSTALL NEW GYPSUM BOARD SOFFIT AT CAFE AS INDICATED. X1202-ESCUSTOM SCUFF MASTER PAINT TO MATCH -GC-GCUSE PRIMER CP-1 ANGLE WALL MOLDING FOR REVEAL. MATCH CEILING GRID P577 - EGGSHELL COMPANY COLOR WHEN APPLICABLE. 7.INSTALL NEW GYPSUM BOARD CEILING AT RESTROOMS AND X1202-SGCUSTOM SCUFF MASTER PAINT TO MATCH -GC-GCUSE PRIMER CP-1 HALLWAY AS INDICATED.2401 UTAH AVENUE SOUTH P577 - SEMIGLOSS D.LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH SEATTLE, WASHINGTON 98134 RETAIL CEILING PAINT COLOR, ABOVE THE WORKROOM 8.INSTALL NEW 2' X 4' ACT CEILING AS INDICATED. (206) 318-1575 CEILING AT MANAGER'S DESK FOR FUTURE USE. PAINT EXPOSED CEILING SURFACE AS INDICATED. 9. THESE DRAWINGS AND SPECIFICATIONS ARE E.PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR CONFIDENTIAL AND SHALL REMAIN THE SOLE FIXTURES OR SUPPORTS. 10.PAINT EXPOSED HVAC SUPPLY/ RETURN GRILLES TO MATCH PROPERTY OF STARBUCKS CORPORATION, ADJACENT CEILING COLOR. WHICH IS THE OWNER OF THE COPYRIGHT IN F.HEATING, VENTILATING AND AIR CONDITIONING (HVAC) THIS WORK. THEY SHALL NOT BE SHOWN FOR DESIGN INTENT ONLY. CONTACT PROJECT 11.REFER TO INTERIOR ELEVATIONS FOR MENU BOARD SPACING. UX1208 SW7005SW7005SW7005 REPRODUCED (IN WHOLE OR IN PART), SHARED MANAGER IF CHANGED. WITH THIRD PARTIES OR USED IN ANY MANNER (N) GYP. BD. SOFFIT (N) 2' X 4' CIRRUS 12.INSTALL LED WALL WASHER LIGHTS AS INDICATED. ON OTHER PROJECTS OR EXTENSIONS TO THIS AT 9' - 9" AFFPANEL CEILING G.DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL PROJECT WITHOUT THE PRIOR WRITTEN AT 10' - 6" AFF CEILING TILE TO BE CENTERED IN TILE, PAINTED TO MATCH 13.INSTALL NEW RECESSED CAN LIGHTS AS INDICATED. 69 CONSENT OF STARBUCKS CORPORATION. ADJACENT FINISHES, TYPICAL. 3 A10017 THESE DRAWINGS AND SPECIFICATIONS ARE 10017 A 14.EXISTING TROFFER LIGHTS TO REMAIN. INTENDED TO EXPRESS DESIGN INTENT FOR A H.PAINT ALL EXPOSED HVAC DUCTS, HVAC DIFFUSERS, 23 PROTOTYPICAL STARBUCKS STORE (WHICH IS 23 RECESSED SPEAKERS, LIGHT TRIM RINGS, PIPING, CONDUIT 15.INSTALL NEW TROFFER LIGHTS AS INDICATED. SUBJECT TO CHANGE AT ANYTIME) AND DO AND JUNCTION BOXES THE SAME COLOR AS SPECIFIED ON NOT REFLECT ACTUAL SITE CONDITIONS. SURROUNDING CEILING OR SOFFIT UNLESS NOTED MEN 16.EXISTING EXIT SIGN/ EMERGENCY LIGHTS TO REMAIN. NEITHER PARTY SHALL HAVE ANY OBLIGATION OTHERWISE. TYPICAL THROUGHOUT RETAIL AREA OF STORE. RESTROOM NOR LIABILITY TO THE OTHER (EXCEPT STATED 17.RELOCATE EXIT SIGN/ EMERGENCY LIGHTS. LOCATION FOR ABOVE) UNTIL A WRITTEN AGREEMENT IS SW7005SW7005SW7005(14) L14743 I.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' REFERENCE ONLY. GC TO VERIFY WITH LOCAL FIRE MARSHAL L14359 FULLYEXECUTEDBYBOTHPARTIES (2)L12869 NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. PRIOR TO INSTALLATION. 13 (N) GYP. BD. CEILING 12 31 13827 L (2) AT 9' - 0" AFF 12869 L (11) STARBUCKS TEMPLATE VERSION i2017.08.25 J.SEE LIGHTING DESIGN PLAN FOR LIGHTING SCHEDULE, 18.LOCATION OF EXIT SIGN/ EMERGENCY LIGHTS FOR REFERENCE 13 13827 L (11) FIXTURE TYPES AND DIMENSIONED LOCATIONS. 791025 ONLY. GC TO VERIFY WITH LOCAL FIRE MARSHAL PRIOR TO 17 INSTALLATION. K.ADJUST EACH CANS AT MENU BOARD LIGHTING SO LIGHT 30 Design Forum BEAMS ARE POINTING CONSISTENTLY, JUST BELOW THE 19.EXISTING SECURITY CAMERAS TO REMAIN. HALLWAY CENTER OF EACH MENU BOARD PANEL. 20.RELOCATE EXISTING SECURITY CAMERAS, GC TO COORDINATE SW7005SW7005SW7005 Architects Inc. SECURITY CAMERA QUANTITY AND LOCATION WITH STARBUCKS' 1161130 (N) GYP. BD. CEILING L 700 W. Pete Rose Way, Suite 460Donald J. Rethman CONSTRUCTION MANAGER. Cincinnati, OH 45203Architect In Charge AT 9' - 0" AFF L11611 Tel: (513) 421-2210License: AR19700147 18 791025 21.EXISTING WALL MOUNTED SPEAKERS TO REMAIN. 18 (2) 13L12869 22.RELOCATE EXISTING WALL MOUNTED SPEAKERS AT MAXIMUM (2)Design Forum L13827 WOMEN HEIGHT ALLOWABLE AS INDICATED. RESTROOM NOTE : CAFE/SEATING (9)F12716 Engineering 23.INSTALL NEW WALL MOUNTED SPEAKERS AT MAXIMUM HEIGHT REFER SHEET I-1107.1 FOR LIGHTING AND DIMENSION. SW7005SW7005SW7005 (44) 11458 L 25 ALLOWABLE. REFER SHEET I-1105.1 FOR FURNITURE SCHEDULES. 35 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE (44) L13242 (N) GYP. BD. CEILING 17 Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 AT 9' - 0" AFF L14518 (44)24.EXISTING HVAC SUPPLY/ RETURN DIFFUSER GRILLES TO REMAIN. (2) 14895 L 2531 791013 25.RELOCATE HVAC SUPPLY/ RETURN DIFFUSER GRILLES. 28 L14359 REFER TOP MECHANICAL DRAWINGS FOR MORE INFORMATION. (2) 12869 L 13 22 (2) L13827 LOCATION OF ALL SWITCHING. 26. 36 27.INSTALL AIR-CURTAIN OVER DT WINDOW AS INDICATED. UX1207 28.INSTALL PICTURE LIGHTS AS INDICATED. REFER TO INTERIOR 2 ELEVATIONS FOR MOUNTING HEIGHTS. 21 RETAIL 29.EXISTING WORDMARK TO REMAIN. 11/01/1709/01/17 30.LINE OF SOFFIT / HEADER. 31.INSTALL RESTROOM WALL SCONCES AS INDICATED. REFER 16 TO RR ELEVATION FOR MOUNTING HEIGHTS. L 32.EXISTING INTERIOR SUSPENDED LOGO DISK TO REMAIN. L Y E 33.EXISTING EXTERIOR WALL SCONCES TO REMAIN W D K 34.EXISTING EXTERIOR AWNING TO REMAIN. FABRIC TO BE RESPONSIBILITY LEGEND REPLACED. P L L BEVERAGE 16 SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR E 3 35.INSTALL ROLLER SHADES AS INDICATED. 12 L 3 PREP. Z E (9) 1474314743 LL 29 FURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS SB-SB 0 36.EXISTING EXTERIOR SECURITY LIGHT TO REMAIN. 19 25 1120 A D6 4 GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY L 11611 L H 35 GENERAL CONTRACTOR E N 30 (2) 18 X1405 F I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt WORKROOM Z & NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS , A 24 35 L DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION T 1426 H E FX1406 TYP. OF 4 S 0 36 M 7 1 R 1 (N) HEADER LIGHTING FIXTURE SCHEDULE - "L" 19 3 A 3 AT 8' - 0" AFF 32 1 1C DESIGN IDCOUNTDESCRIPTIONRESP.BULBCOMMENTS 15 30 EXIT 15057(3) L STORE #:8123 116113EMERGENCY EXIT LIGHT - WHITESB-GCLED 5W LOW ENERGYGREEN OR EQUALLETTERING PROJECT #:25450-048 12869 L(2) 13 116491EMERGENCY LIGHT DOUBLE - WHITESB-GCCED; GREEN ISSUE DATE: 11/1/17 (2) L13827LETTERING DESIGNER: LISA MACEDA R OTHER LEED AP: 27 PRODUCTION DESIGNER: 148952LED PICTURE LIGHT TRADITIONAL - 36INSB-GCINTEGRATED LEDPETER CHEETHAM 2221 915MM - BRONZECHECKED BY: RECESSED CAN 33 1145844CAN - RECESSED HOUSING ADJUSTABLE -SB-GC(1) 14518 - LED PAR 30 Revision Schedule TYP. OF 2 5IN 125MM - NEW CEILING850LM NFL WHITE, OR EQUAL RevDateByDescription 1286919CAN - RECESSED TRIM BAFFLE - 5IN 125MM -SB-GC WHITE 1324244CAN - RECESSED TRIM ADJUSTABLE GIMBALSB-GC C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 11302WD0073 U L11649 U10517 UX1207 RING - 5IN 125MM - WHITE 33 (E) 2' X 4' ACT CEILING (N) 2' X 4' ACT CEILING (N) WOODEN SOFFIT (N) 2' X 2' ACT CEILING 18 1382719CAN - RECESSED INTEGRATED LED HOUSINGSB-GC AT 9' - 10" AFFAT 13' - 6" AFFAT 9' - 6" AFF 2 TYP. OF 3 AT 9' - 0" AFF - 5IN 125MM - 900LM NEW CEILING 8 34 15 4 SCONCE SHEET TITLE: 143592SCONCE - PRISMATIC GLASS SHADE - CLEARSB-GCINTEGRATED LED REFLECTED CEILING STRIP REFLECTED CEILING PLAN 1474323STRIP - LED WALL WASHER - 37IN 940MM -SB-GCINTEGRATED LED@ DEMISING 1 N PLAN Scale: 1/4" = 1'-0" SILVERWALL AND 1/4" = 1'-0" SCALE: BACKBAR 02'4'8'TROFFER SHEET NUMBER: 150573TROFFER - LED RECESSED - 24X48INSB-GCINTEGRATED LEDCED Scale: 1/4" = 1'-0" 600X1200MM - WHITE - 3900LM I-1107 10/31/2017 6:21:30 PM LIGHTING FIXTURE SCHEDULE - "L" DIMENSIONED CEILING DESIGN IDCOUNTDESCRIPTIONRESP.BULBCOMMENTS EXIT AND LIGHTING PLAN NOTES SHEET NOTES 116113EMERGENCY EXIT LIGHT - WHITESB-GCLED 5W LOW ENERGYGREEN OR EQUALLETTERING 1.EXISTING 2' X 4' ACT CEILING TO REMAIN. PATCH AND REPAIR A.WHERE ACT CEILING MEETS WALL, PROVIDE ANGLE WALL 116491EMERGENCY LIGHT DOUBLE - WHITESB-GCCED; GREEN CEILING AS REQUIRED FOR NEW WORK.MOULDING FOR REVEAL. MATCH CEILING GRID COLOR WHEN LETTERING APPLICABLE. OTHER 2.EXTEND NEW ACT CEILING GRID. PROVIDE NEW FULL TILE 148952LED PICTURE LIGHT TRADITIONAL - 36INSB-GCINTEGRATED LED WHERE APPLICABLE. ALIGN NEW CEILING GRID WITH B.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE 915MM - BRONZE EXISTING.STARBUCKS' NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-119 FOR PAINT R RECESSED CAN 3.INSTALL NEW 2' X 4' CIRRUS PANEL CEILING AT CAFE AS SCHEDULES. 1145844CAN - RECESSED HOUSING ADJUSTABLE -SB-GC(1) 14518 - LED PAR 30 INDICATED. C 2017 STARBUCKS COFFEE COMPANY 5IN 125MM - NEW CEILING850LM NFL WHITE, OR C.ALL FIXTURES IN FOOD PREPARATION AREA SHALL HAVE EQUAL 4.INSTALL NEW 2' X 2' ACT CEILING AS INDICATED.SHATTERPROOF LAMPS IF THE FIXTURE IS NOT LENSED. 1286919CAN - RECESSED TRIM BAFFLE - 5IN 125MM -SB-GC STARBUCKS COFFEE WHITE PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR 5.INSTALL NEW WOODEN SOFFIT AT BACKBAR AS INDICATED.D. 1324244CAN - RECESSED TRIM ADJUSTABLE GIMBALSB-GC FIXTURES/SUPPORTS.COMPANY RING - 5IN 125MM - WHITE 6.INSTALL NEW GYPSUM BOARD SOFFIT AT CAFE AS INDICATED. 2401 UTAH AVENUE SOUTH 1382719CAN - RECESSED INTEGRATED LED HOUSINGSB-GC E.ADJUST FOCUS OF ALL TRACK AND RECESSED SEATTLE, WASHINGTON 98134 - 5IN 125MM - 900LM NEW CEILING 7.INSTALL NEW GYPSUM BOARD CEILING AT RESTROOMS AND DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL HALLWAY AS INDICATED.ARTWORK, MENU BOARDS, AND MERCHANDISE BAYS. (206) 318-1575 SCONCE 143592SCONCE - PRISMATIC GLASS SHADE - CLEARSB-GCINTEGRATED LED IF PENDANT SUSPENDED LENGTH EXCEEDS 48" (1220MM) 8.INSTALL NEW 2' X 4' ACT CEILING AS INDICATED.F. THESE DRAWINGS AND SPECIFICATIONS ARE STRIP FROM CEILING, REPLACE WITH SURFACE-MOUNTED PENDANT CONFIDENTIAL AND SHALL REMAIN THE SOLE 1474323STRIP - LED WALL WASHER - 37IN 940MM -SB-GCINTEGRATED LED@ DEMISING 9.INSTALL PICTURE LIGHTS AS INDICATED. REFER TO INTERIOR AND SUSPEND WITH GC-SUPPLIED CONDUIT AND J-BOX TO PROPERTY OF STARBUCKS CORPORATION, SILVERWALL AND ELEVATIONS FOR MOUNTING HEIGHTS.DIMENSIONED HEIGHT. WHICH IS THE OWNER OF THE COPYRIGHT IN BACKBAR (N) 2' X 4' CIRRUS PANEL (N)GYP. BD. SOFFIT THIS WORK. THEY SHALL NOT BE CEILING AT 10' - 6" AFF TROFFER AT 9' - 9" AFF 10.INSTALL NEW RECESSED CAN LIGHTS AS INDICATED. G.CENTER EMERGENCY/EXIT LIGHTS ABOVE DOORS, UON. REPRODUCED (IN WHOLE OR IN PART), SHARED CENTRALISED ON CELING TILES (WHERE APLLICABLE). WITH THIRD PARTIES OR USED IN ANY MANNER 150573TROFFER - LED RECESSED - 24X48INSB-GCINTEGRATED LEDCED 3 6 H.FIXTURES IN ACT ARE TO BE LOCATED ALONG CENTERLINE 600X1200MM - WHITE - 3900LMON OTHER PROJECTS OR EXTENSIONS TO THIS 11 11.INSTALL LED WALL WASHER LIGHTS AS INDICATED.UON. PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. TYP. OF 14 12.EXISTING TROFFER LIGHTS TO REMAIN. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A 13.INSTALL NEW TROFFER LIGHTS AS INDICATED. PROTOTYPICAL STARBUCKS STORE (WHICH IS 2' - 0"2' - 0"3' - 8"2' - 0"7' - 6"5' - 0"6' - 0"7' - 6"2' - 0"3' - 9"2' - 0"1' - 10" 14 SUBJECT TO CHANGE AT ANYTIME) AND DO 14.INSTALL RESTROOM WALL SCONCES AS INDICATED. EQ6' - 0"EQNOT REFLECT ACTUAL SITE CONDITIONS. EQ REFER TO RR ELEVATIONS FOR MOUNTING HEIGHTS. NEITHER PARTY SHALL HAVE ANY OBLIGATION MEN 4' - 4" NOR LIABILITY TO THE OTHER (EXCEPT STATED 10 RESTROOM 15.EXISTING EXTERIOR SECURITY LIGHT TO REMAIN. ABOVE) UNTIL A WRITTEN AGREEMENT IS (N)GYP. BD. CEILING 10 TYP. OF 11 2' - 0"2' - 0" 17 FULLYEXECUTEDBYBOTHPARTIES AT 9' - 0" AFF EQ TYP. OF 2 16.EXISTING EXIT SIGN/ EMERGENCY LIGHTS TO REMAIN. 45' - 2" 7 STARBUCKS TEMPLATE VERSION i2017.08.25 17.RELOCATE EXIT SIGN/ EMERGENCY LIGHTS. LOCATION FOR 4 REFERENCE ONLY. GC TO VERIFY WITH LOCAL FIRE MARSHAL 9 3' - 11 1/2" I-5002 PRIOR TO INSTALLATION. EQ6' - 0"EQ Design Forum EQ 4' - 4"8' - 0"2' - 0"2' - 0"2' - 0"2' - 0"6' - 0"2' - 0"2' - 0"2' - 0" 18.LOCATION OF EXIT SIGN/ EMERGENCY LIGHTS FOR HALLWAY REFERENCE ONLY. GC TO VERIFY WITH LOCAL FIRE MARSHAL (N)GYP. BD. CEILING Architects Inc. PRIOR TO INSTALLATION. 18 10 AT 9' - 0" AFF 700 W. Pete Rose Way, Suite 460Donald J. Rethman 6 TYP. OF 2 Cincinnati, OH 45203Architect In Charge EQ 19.EXISTING EXTERIOR WALL SCONCES TO REMAIN. 7 I-5002 Tel: (513) 421-2210License: AR19700147 18 20.REFER DETAIL 1/I-5002 AND PERSPECTIVE FOR THIS AREA. EQ 17 Design Forum EQ6' - 0"EQ EQ Engineering 15 9 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 10 Cincinnati, OH 45203Professional Engineer EQ License: PE10504904 Tel: (513) 421-2210 TYP. OF 2 WOMEN EQ 14 RESTROOM (N)GYP. BD. CEILING AT 9' - 0" AFF 7 2 4' - 5"6' - 0"2' - 0"3' - 0"8' - 0" 11/01/1709/01/17 16 RETAILCAFE/SEATING EXISTING ROOF STRUCTURE 1 L 5' - 1"1' - 5"1' - 5" 1/8"DIA STEEL GALVANIZE I-5002 ROD SPACED @ 4'-0" O.C. L MAX. SECURED TO STEEL Y E TRUSS ABOVE W/ SHIELDS 10 W D 16TYP. OF 44 K 10'- 6" AFF BEVERAGE P L B/O ACT CEILING 18 PREP. L E 3 2 L 3 9'- 6" AFF Z RECESSED CAN LIGHT I-1107.1 E 7 0 B/O WOOD SOFFIT (TYP.) A D6 TYP. OF 9 11 I-5002 32' - 2" 4 L MITER JOINT H 20 E N 12 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt WORKROOM Z WOOD SOFFIT 5/8" TYPE "X" & TYP. OF 4 , PLYWOOD ON 20 GA 3-5/8" A 15 L 2' - 0" MTL STUD. @ 16" O.C. T H E (N) HEADER FINISH: WD0073 AT 8' - 0" AFF S 0 M LED STRIP LIGHT 7 1 R 2 13 1 10 3 A 3 I-5002 TYP. OF 3 TYP. OF 2 1 1C MENU BOARDZEPHYR FOOD CASE BACKBAR SHELF 2 STORE #:8123 5 TILE FINISH AS I-5002 PROJECT #:25450-048 18 SCHEDULED ISSUE DATE: 11/1/17 DESIGNER: BACKBAR LISA MACEDA 10' - 6" (B/O ACT CEILING) R LEED AP: CASEWORK 19 PRODUCTION DESIGNER: 9' - 6" (B/O WOOD SOFFIT)PETER CHEETHAM TYP. OF 2 CHECKED BY: 8' - 0" (T/O BACKBAR SHELF) Revision Schedule RevDateByDescription 6' - 0" (B/O MENU BOARD) 19 (E)2' X 4' ACT CEILING AT (N) 2' X 4' ACT CEILING (N)WOODEN SOFFIT (N)2' X 2' ACT CEILING 2' - 10" TYP. OF 3 9' - 10" AFFAT 13' - 6" AFFAT 9' - 6" AFFAT 9' - 0" AFF C:\\Users\\zach.scholl\\Documents\\Starbucks_131st (COUNTER TOP) 8 1 5 4 1 I-5001 SHEET TITLE: DIMENSIONED CEILING AND LIGHTING PLANBACKBAR SECTION DIMENSIONED CEILING 12 N Scale: 1/4" = 1'-0"Scale: 1/2" = 1'-0" AND LIGHTING PLAN AS SHOWN SCALE: 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" I-1107.1 10/31/2017 6:21:37 PM FLOOR FINISH PLAN NOTES FLOOR TREATMENT SCHEDULE - "T" A.STARBUCKS TO SUPPLY RETAIL FLOOR TILE AND TILE DESIGN IDAREADESCRIPTIONRESP.COMMENTS BASE. GENERAL CONTRACTOR TO INSTALL. GENERAL PLASTIC CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND X120313 SFHELIX Z1 - U/V RESISTANTE PVC/NBRSB-GCRECESSED TAPERED ANGLE FRAMEINSTALL. GENERAL CONTRACTOR TO SUPPLY AND INSTALL COMPOUND - 12" x 9" x 1/2" DEEP WITHFRAME, COLOR: BLACK MORTAR, ADHESIVE, AND GROUT. GENERAL CONTRACTOR HIDDEN INTERLOCKING CONNECTOR TO INSPECT ALL TILES AND REJECT DAMAGED OR SUBSTANDARD TILES PRIOR TO INSTALLATION. TILE 122030 SFTILE - GRAPHITE - 12X24IN 300X600MMSB-GCGROUT GR0008: MAPEI 10 - BLACK; B.ALL TILE AND SLATE TO BE INSTALLED PER TILE COUNCIL OF R LATICRETE 45 - RAVEN AMERICA STANDARDS. 14855572 SFTILE - COARSE DARK GREY - 12X24INSB-GCGROUT GR0007: MAPEI - 47 C 2017 STARBUCKS COFFEE COMPANY 300X600MMCHARCOAL; LATICRETE - 35 MOCHA C.ALL FLOORING AND BASE MATERIAL TO BE INSTALLED 177931941 SFTILE - WARM GREY CEMENT PATTERN -SB-GCGROUT GR0007: MAPEI - 47 ACCORDING TO STARBUCKS SPECIFICATIONS. 24X24IN 600X600MMCHARCOAL; LATICRETE - 35 MOCHA STARBUCKS COFFEE D.CABINET BASES TO BE SET AFTER TILE INSTALLATION. COMPANY E.ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN. WALL BASE SCHEDULE - "B" 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 F.FOR CARPET INSTALLATION, REFER TO MANUFACTURERS DESIGN IDLENGTHDESCRIPTIONRESP.COMMENTS INSTALLATION INSTRUCTIONS. (206) 318-1575 FLOOR TRIM X12060"SCHLUTER SCHIENE E 100/V4ASB-GC3'-6" THESE DRAWINGS AND SPECIFICATIONS ARE TILE BASE CONFIDENTIAL AND SHALL REMAIN THE SOLE 13101359' - 7 3/4"TILE BASE - GRAPHITE - 6X12IN 150X300MMSB-GCGROUT GR0007: MAPEI 47 - PROPERTY OF STARBUCKS CORPORATION, CHARCOAL; LATICRETE 35 - MOCHA; WHICH IS THE OWNER OF THE COPYRIGHT IN USE WITH OUTSIDE CORNER TILE SHEET NOTES THIS WORK. THEY SHALL NOT BE 12300 REPRODUCED (IN WHOLE OR IN PART), SHARED 1.INSTALL TILE FLOORING AND TILE BASE IN CAFE, BACKBAR, 14856169' - 6 1/4"TILE BASE - COARSE DARK GREY - 6X12INSB-GCGROUT GR0007: MAPEI 47 - WITH THIRD PARTIES OR USED IN ANY MANNER RESTROOMS AND RESTROOM VESTIBULE AS INDICATED. 150X300MMCHARCOAL; LATICRETE 35 - MOCHA ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN 2.NEW FLOOR SINK/ FLOOR DRAIN LOCATION. SEE PLUMBING CONSENT OF STARBUCKS CORPORATION. DRAWINGS. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A 3. EXISTING COLUMN TO REMAIN. PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 4.INSTALL WALK-OFF MAT AT ENTRY VESTIBULE AS INDICATED. NOT REFLECT ACTUAL SITE CONDITIONS. CUT OUT TILES AS REQUIRED PER MANUFACTURER'S NEITHER PARTY SHALL HAVE ANY OBLIGATION TILE BASETILE FIELD SPECIFICATIONS. MEN NOR LIABILITY TO THE OTHER (EXCEPT STATED 1 1 B13101T17793 ABOVE) UNTIL A WRITTEN AGREEMENT IS RESTROOM 5.TILE START POINT WHERE INDICATED. FULLYEXECUTEDBYBOTHPARTIES 6.PASTRY CASE FOOTPRINT. STARBUCKS TEMPLATE VERSION i2017.08.25 TILE BASE 7. INSTALL FLOOR TILE IN WORKROOM AS INDICATED. 13101 B 1 2 4 8.INSTALL NEW TILE BASE AT WORKROOM AS INDICATED. Design Forum I-5004 6 TILE FIELD 9.INSTALL SCHLUTER TRIM AS INDICATED. I-5004 T17793 1 Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge TILE BASE Tel: (513) 421-2210License: AR19700147 B13101 1 TILE FIELD Design Forum T17793 FLOOR FINISH LEGEND 1 Engineering HALLWAY 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer 3 License: PE10504904 Tel: (513) 421-2210 WALK-OFF MAT - HELIX Z1 TX1203 I-5004 CAFE/SEATING TILE BASE 1 13101 B 2 6 TILE - WARM GREY - 24X24IN I-5004 T17793 WOMEN 600X600MM RESTROOM TILE BASE TILE FIELD 13101 B 3 T17793 1 1 11/01/1709/01/17 TILE - COARSE DARK GREY - T14855 12X24IN 300X600MM 9 5 RETAIL I-5004 3 L I-5004 4 X1203 T L TILE BASE - GRAPHITE - 6X12IN B13101 Y WALK-OFF MAT E 150X305MM N.) W 1 TILE BASE D 2 K 3' - 4" 4 (MI I-5004 TILE BASE - COARSE DARK GREY B14856 B13101 1 P I-5004 L I-5004 - 6X12IN 150X300MM L E 3 2 4' - 0" L 3 DATUM POINT Z E 0 (MIN.) A D6 2 4 62 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , 9 A L BX1206 TILE BASE T BEVERAGE RESPONSIBILITY LEGEND H E 5 8 B14856 PREP. S 0 M I-5004 SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR TILE BASE 2 7 2 1 2 R 14856 B 8 1 SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS 3 A 3 1 1C GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY 7 GENERAL CONTRACTOR I-5004 STORE #:8123 TILE FIELD NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS T14855 7 PROJECT #:25450-048 DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION ISSUE DATE: 11/1/17 8 DESIGNER: LISA MACEDA R LEED AP: I-5004 PRODUCTION DESIGNER: PETER CHEETHAM WORKROOM 2 CHECKED BY: 2 2 2 Revision Schedule RevDateByDescription 5 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 13101 B 1 17793 T1 SHEET TITLE: TILE FIELDTILE BASE FLOOR FINISH PLAN 1/4" = 1'-0" FLOOR FINISH PLAN SCALE: 1 N Scale: 1/4" = 1'-0" SHEET NUMBER: 02'4'8' Scale: 1/4" = 1'-0" I-1109 10/31/2017 6:21:44 PM WALL FINISH PLAN NOTES WALL TREATMENT (AREA) SCHEDULE - "Q"PAINT SCHEDULE DESIGN IDAREADESCRIPTIONRESP.COMMENTSCOLOR CODEDESCRIPTIONLRVRESP.COMMENTS A.WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS. EXTERIORSW6165SW - 616524GC-GCUSE PRIMER CP-1 X12107 SFBRICK - NATURALGC-GCCOLOR MATCH TO EXISTING PRIORSW7005Paint - SW7005 PURE WHITE84GC-GCUSE PRIMER CP-1 B.INSTALL CLEAR CORNER GUARDS AS INDICATED. MOUNT TO CONSTRUCTION. CONTACT: MATT SW9138SW - STARDEW43GC-GCUSE PRIMER CP-1 AT 6Ñ (150MM) AFF. BACK-PAINT WITH CORRESPONDING MYER - EDGEWOOD BUILDING X1202-ESCUSTOM SCUFF MASTER PAINT TO MATCH -GC-GCUSE PRIMER CP-1 WALL COLOR. ADHERE WITH CLEAR SILICONE ADHESIVE SUPPLY 317-525-8718 P577 - EGGSHELL AND #6 STAINLESS STEEL OVAL HEAD SCREWS 3Ñ (75MM) PLASTIC X1202-SGCUSTOM SCUFF MASTER PAINT TO MATCH -GC-GCUSE PRIMER CP-1 FROM ENDS, 12Ñ (300MM) ON CENTER. OFFSET SCREWS R 114691961 SFFRP - WHITEGC-GCMARLITE OR EQUAL P577 - SEMIGLOSS ON EITHER SIDE BY 1/2" (10MM) VERTICALLY. CUT CORNER TILE GUARDS TO FIT BELOW CHAIR RAIL AT APPLICABLE C 2017 STARBUCKS COFFEE COMPANY LOCATIONS. DO NOT INSTALL CORNER GUARDS ABOVE 12205131 SFTILE - MOTTLED WHITE - 2X8IN 50X205MMSB-GCGROUT GR0002: MAPEI - 93 WARM CHAIR RAIL. GREY; LATICRETE - 90 LIGHT PEWTER 14694194 SFTILE - OCEANSIDE BLUE - 2X8IN 50X200MMSB-GCGROUT: MAPEI - 103 COBBLESTONE STARBUCKS COFFEE C.INSTALL METAL CORNER GUARDS AS INDICATED. MOUNT WALL TREATMENT (LENGTH) SCHEDULE- "R" 18311401 SFTILE - OLIVE DRAB BURLAP TEXTURE -SB-GCGROUT GR0007: MAPEI - 47 AT 6Ñ (150MM) AFF. AFFIX WITH #6 STAINLESS STEEL OVAL 12X24IN 300X600MMCHARCOAL; LATICRETE - 35 MOCHA COMPANY HEAD SCREWS 3Ñ (75MM) FROM ENDS, 12Ñ (300MM) ON DESIGN IDLENGTHDESCRIPTIONRESP.COMMENTS WALL COVERING CENTER OFFSET SCREWS ON EITHER SIDE BY 1/2" (10MM) 2401 UTAH AVENUE SOUTH TRIM 17779421 SFWALL TEXTURE - BASKET WEAVESB-GCPAINT FINISH: SW9138 VERTICALLY. TO BE INSTALLED IN BACK OF HOUSE ONLY. SEATTLE, WASHINGTON 98134 X10150"SCHLUTER JOLLY A 100 ACGSB-GCSEE DETAIL: 10/I-500533'-4" 17794166 SFVINYL - WALL COVERING - TAUPE BASKETSB-GC (206) 318-1575 X120362' - 6 3/4"SCHLUTER JOLLY A 100 ACGSB-GCLOCATION: RESTROOMS; SEE DETAIL D.CHANGE OF PAINT COLOR ALLOWED AT INSIDE CORNERS WEAVE TEXTURE 2/I-5003 ONLY. X1201444 SFDREAMSCAPE WALLCOVERING / ARTSB-GC THESE DRAWINGS AND SPECIFICATIONS ARE X12070"SCHLUTER INDEC IN 100 ACGSB-GCLOCATION: BEVERAGE PREP; SEE 22'-6" WOOD CLADDING CONFIDENTIAL AND SHALL REMAIN THE SOLE DETAIL: E.REFER TO INTERIOR ELEVATIONS FOR GRAPHICS PROPERTY OF STARBUCKS CORPORATION, WD0073129 SFWOOD - WHITE OAK WD0073 MAD100SB-GCWOOD CLADDING LOCATIONS. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE F. REFER TO CASEWORK FINISH SCHEDULE FOR ADDITIONAL REPRODUCED (IN WHOLE OR IN PART), SHARED INFORMATION WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS G. GENERAL CONTRACTOR TO PROVIDE AND INSTALL PROJECT WITHOUT THE PRIOR WRITTEN WORKROOM WALL FINISHES. CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO SHEET NOTES 1NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION I-4102 NOR LIABILITY TO THE OTHER (EXCEPT STATED 1.GC TO INSTALL BACKBAR WALL TILE AS INDICATED ON ABOVE) UNTIL A WRITTEN AGREEMENT IS INTERIOR ELEVATIONS. FULLYEXECUTEDBYBOTHPARTIES BACKBAR WALL TILE TO RETURN TO MULLIONS WITH JOLLY 2. STARBUCKS TEMPLATE VERSION i2017.08.25 CORNERS WITHIN DRIVE-THRU WINDOW OPENING AS INDICATED. 5 1 4 MEN 3. INSTALL WALL TILE AT RESTROOMS AS INDICATED. Design Forum RESTROOM 4 I-4102.1 42 4 4.REFER TO SHEETS I-5005 FOR WALL FINISH DETAILS. 34 Architects Inc. 5.INSTALL FRP BEHIND BACKLINE CABINETS BELOW 4 3 700 W. Pete Rose Way, Suite 460Donald J. Rethman COUNTERTOPS TO TOP OF BASELINE. SEE DETAIL ON I-5004 Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 6.INSTALL NEW FRP AT WORKROOM AREA AS INDICATED. 8 1 HALLWAY 10 SIM. 7.WOOD CLADDING AS INDICATED ON INTERIOR ELEVATION. 14 3 Design Forum I-5005 8.INSTALL SOLID WOOD TRIM AT CORNERS AS INDICATED. I-2103 42 10 Engineering I-2101 PAINTED TO MATCH ADJACENT FINISH. 21 10 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 8 9.PROVIDE FIRE TREATED WOOD BLOCKING AS REQUIRED TO 3 Cincinnati, OH 45203Professional Engineer 10 License: PE10504904 Tel: (513) 421-2210 SUPPORT ANY WALL ATTACHMENTS. 5 4 WOMEN I-5013 RESTROOM I-4102.1 86 4 CAFE/SEATING 4 34 4 4 4 I-5005 7 4 9 8 11/01/17 09/01/17 WALL TREATMENT LEGEND 8 8 3 INDICATES PARTIAL-HEIGHT FRP Q11469 TYP. 1 18 3 WD0073 I-5005 INDICATES WOOD CLADDING L 2 L I-2102 4 Y 3 9 Q11469 INDICATES FULL - HEIGHT FRP E 3 W D 1 8 K Q18311 RETAIL INDICATES RESTROOM WALL TILE P L 4 L E 3 DREAMSCAPE PRINTED QX1201 L 3 Z WALLCOVERING 5 E 0 WORKROOM A D6 INDICATES BACKBAR TILE Q14694 69 4 L 6 H E N I-2104 12 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt INDICATES DT AREA TILE Q12205 Z 2 & 14 , 7 BEVERAGE A I-5005 L T INDICATES WALLCOVERING H PREP. E Q17779 I-2102 8 33 TO BE PAINTED WITH SW9138 8 16 S 0 16 M 579 10 I-5005 7 1 INDICATES WALLCOVERING 2 R Q17794 I-5005 I-5005 1 3 9 3 A 3 3 6 6 1 1C INDICATES SCUFF MASTER X1202 10 1 3 STORE #:8123 11 6 6 PROJECT #:25450-048 I-5005 ISSUE DATE: 11/1/17 12 3DESIGNER: LISA MACEDA RESPONSIBILITY LEGEND 7 5 R 2 I-5005 7 LEED AP: 6 3 PRODUCTION DESIGNER: PETER CHEETHAM I-5005 SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR I-5005 CHECKED BY: 33 I-2103 68 7 3 17 113 FURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS SB-SB I-5005 Revision Schedule 7 5 GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY 3 3 GENERAL CONTRACTOR 33 RevDateByDescription 8 NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 2 SHEET TITLE: I-2102 7 7 5 WALL FINISH PLAN WALL FINISH PLAN 6 1 N Scale: 1/4" = 1'-0" 1/4" = 1'-0" SCALE: 02'4'8' SHEET NUMBER: Scale: 1/4" = 1'-0" I-1111 10/31/2017 6:21:52 PM WALLCOVERING 4 1321 12716X1405X1406X1407 FFF5F PAINTED WITH SW9138 1271612716X1404 FFG I-5002 F12716Q17779 F12716 FF1271612716 SHEET NOTES INTERIOR ELEVATION NOTES 3" REFER TO MANUFACTURERS INSTRUCTIONS SHIPPED WITH 1.RELOCATED EXISTING WALL MOUNTED SPEAKER AT A. ARTWORK FOR INSTALLATION INSTRUCTIONS AND SPACING. MAXIMUM HEIGHT ALLOWABLE AS INDICATED. SEE EQEQ LIGHTING PLAN. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE. RUN B. " 9 BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS, 2.EXISTING EXIT/ EMERGENCY LIGHTS TO REMAIN. - R ' F I NOT BEHIND CABINETS. 9 V 1 3.INSTALL CONDIMENT CART AS INDICATED. R C 2017 STARBUCKS COFFEE COMPANY PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS C. NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING INSTALL MERCH BAYS AS INDICATED. 4. PAINTS. STARBUCKS COFFEE 5.EXISTING INTERIOR SUSPENDED LOGO DISK TO PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS REMAIN. D. COMPANY OTHERWISE NOTED; -ALL WOOD AND METAL SURFACES SHALL BE 2401 UTAH AVENUE SOUTH 6.INSTALL CORIAN PANEL AS INDICATED. PAINTED SEMIGLOSS, OR EQUAL. SEATTLE, WASHINGTON 98134 10' - 6" B/O CEILING -ALL ACCENT AND TRIM PAINT TO BE SEMIGLOSS, 7.INSTALL NEW PICTURE LIGHTS AS INDICATED. 9' - 9" B/O SOFFIT (206) 318-1575 TETET ETET ETET OR EQUAL. ET ET -ALL WALL AND CEILING PAINTS TO BE EGGSHELL, 8.INSTALL WOOD TRIM AT OPENING AS INDICATED. 6' - 0" THESE DRAWINGS AND SPECIFICATIONS ARE OR EQUAL. CONFIDENTIAL AND SHALL REMAIN THE SOLE 9.INSTALL NEW WALL MOUNTED SPEAKER AT MAXIMUM PROPERTY OF STARBUCKS CORPORATION, FOR PAINT AND WALL TREATMENT SCHEDULES, REFER TO HEIGHT ALLOWABLE AS INDICATED. SEE LIGHTING E. WHICH IS THE OWNER OF THE COPYRIGHT IN THE WALL FINISH PLAN. FOR GRAPHICS SCHEDULE, REFER PLAN. THIS WORK. THEY SHALL NOT BE C/O COMMUNITY BOARD TO THE FURNITURE, FIXTURES, AND EQUIPMENT PLAN. REPRODUCED (IN WHOLE OR IN PART), SHARED ET 10.GC TO PROVIDE COVER PLATES THROUGHOUT. COVER WITH THIRD PARTIES OR USED IN ANY MANNER PLATE TO MATCH ADJACENT FINISH. ON OTHER PROJECTS OR EXTENSIONS TO THIS 10 CP0002CP0002 PROJECT WITHOUT THE PRIOR WRITTEN WD0073CP0002CP0002 13101CP0002CP0002CP0002CP0002CP0002CP0002CP0002CP0002 B . 14 11.INSTALL NEW EXIT/ EMERGENCY LIGHTS AS INDICATED. CP0002CP0002 TYP. CONSENT OF STARBUCKS CORPORATION. MAD100 6 6 6 THESE DRAWINGS AND SPECIFICATIONS ARE 4' - 7 1/2" 3 6 INSTALL FRY REGLET CUSTOM CORNER GUARDS AT 12. INTENDED TO EXPRESS DESIGN INTENT FOR A CORNERS AS INDICATED. SEE INTERIOR ELEVATIONS CONDIMENT CART PROTOTYPICAL STARBUCKS STORE (WHICH IS FOR CLARIFICATION.SEE DETAIL ON SHEET 4-I/5005. SUBJECT TO CHANGE AT ANYTIME) AND DO STOREFRONT ENTRANCE NOT REFLECT ACTUAL SITE CONDITIONS. 13.EXISTING WALL MOUNTED SPEAKER TO REMAIN. 1 NEITHER PARTY SHALL HAVE ANY OBLIGATION Scale: 3/8" = 1'-0" NOR LIABILITY TO THE OTHER (EXCEPT STATED 14.INFILL WALL TO MATCH ADJACENT FRAMING. ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES 1 WALLCOVERING 7 STARBUCKS TEMPLATE VERSION i2017.08.25 4 I-5002 1 117 WALLCOVERING 7 PAINTED WITH SW9138 6 I-5002 L14895 Q17794Q17779L11611L14895 I-5002 I-5002 Design Forum 3" Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman EQEQ3' - 11 1/2" Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 ALIGNALIGN Design Forum OPEN Engineering OPEN TO TO 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE BEYOND BEYOND Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 10' - 6" B/O CEILING 9' - 9" B/O SOFFIT 9' - 6" B/O SOFFIT 7' - 3" B/O HEADER 7' - 9" C/O PICTURE LIGHT 5' - 4 1/2" C/O ARTWORK5' - 4 1/2" C/O ARTWORK 11/01/1709/01/17 X1401 G SW9138SW9138SW9138SW9138SW9138SW9138GX1402 WD0073WD0073 SW9138SW9138SW9138SW9138SW9138SW9138 12 B13101 10 MAD100 8 8 5' - 9" 4 MERCH BAYS L L MERCH BAYS Y E 2 Scale: 3/8" = 1'-0" W D K P L PRINTED SOFFIT ALL 4 L 9 9 WALLCOVERING E SIDE 3 L I-5002 3 X1201SW7005SW7005SW7005 10017Q A 10017 A Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 10' - 6" B/O CEILING 9' - 9" B/O SOFFIT DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 5' - 7" CHECKED BY: C/O ARTWORK Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 10 B13101 GX1403 TYP. CAFE SEATING 3 SHEET TITLE: Scale: 3/8" = 1'-0" INTERIOR ELEVATIONS 02'4'6' 3/8" = 1'-0" SCALE: Scale: 3/8" = 1'-0" SHEET NUMBER: I-2101 10/31/2017 6:22:12 PM WALLCOVERING PAINTED WITH SW9138 1 Q17779FF1271612716 INTERIOR ELEVATION NOTES SHEET NOTES A.REFER TO MANUFACTURERS INSTRUCTIONS SHIPPED WITH 1.EXISTING INTERIOR SUSPENDED LOGO DISK TO REMAIN. ARTWORK FOR INSTALLATION INSTRUCTIONS AND SPACING. 2.INSTALL MENU BOARDS AS INDICATED. B.INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE. RUN BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS, 3.GC TO INSTALL BACKBAR WALL TILE AS INDICATED. NOT BEHIND CABINETS. SEE DETAIL ON SHEET I-5005 C.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS 4.INSTALL AIR-CURTAIN OVER DT WINDOW AS INDICATED. R NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. 5.INSTALL TRIM AS INDICATED. C 2017 STARBUCKS COFFEE COMPANY D.PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS 6.INSTALL CORIAN PANEL AS INDICATED. OTHERWISE NOTED; STARBUCKS COFFEE -ALL WOOD AND METAL SURFACES SHALL BE PAINTED SEMIGLOSS, OR EQUAL. COMPANY -ALL ACCENT AND TRIM PAINT TO BE SEMIGLOSS, OR EQUAL.2401 UTAH AVENUE SOUTH 10' - 6" B/O CEILING -ALL WALL AND CEILING PAINTS TO BE EGGSHELL, SEATTLE, WASHINGTON 98134 ETET OR EQUAL. (206) 318-1575 E.FOR PAINT AND WALL TREATMENT SCHEDULES, REFER TO THESE DRAWINGS AND SPECIFICATIONS ARE THE WALL FINISH PLAN. FOR GRAPHICS SCHEDULE, REFER CONFIDENTIAL AND SHALL REMAIN THE SOLE TO THE FURNITURE, FIXTURES, AND EQUIPMENT PLAN. PROPERTY OF STARBUCKS CORPORATION, 2' - 10" WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER NOTE: ON OTHER PROJECTS OR EXTENSIONS TO THIS ALL MECHANICAL SHOWN FOR REFERENCE ONLY, SEE CP0002CP000213101CP0002CP0002CP0002CP0002WD0073WD0073 B PROJECT WITHOUT THE PRIOR WRITTEN MECHANICAL SHEETS FOR MORE INFORMATION. 1' - 10"2' - 10"12' - 6"6' - 9"5' - 6" WOOD SLAT CONSENT OF STARBUCKS CORPORATION. 6 THESE DRAWINGS AND SPECIFICATIONS ARE NITROHOPESPRESSOPOS AND SAFEZEPHYR PASTRY CASE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. FRONT BAR (CUSTOMER SIDE) NEITHER PARTY SHALL HAVE ANY OBLIGATION 1 Scale: 3/8" = 1'-0" NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS 222222 1 6 WOOD CLADDING FULLYEXECUTEDBYBOTHPARTIES 3 5 G12839G12839G12839G12839G12839G12839 MAD100I-5012 I-5002 14694WD0073WD007314694128371283812837128371283712837 QQGGGGGGSTARBUCKS TEMPLATE VERSION i2017.08.25 Design Forum Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 16 2 Design Forum I-5005 OPEN I-5002 Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 10' - 6" B/O CEILING 9'-6" B/O SOFFIT 4' - 9" B/O TEA SHELF CP0002CP0002 CP0002CP0002CP0002CP0002CP0002CP0002 PL0003PL0003 B13101CP0002CP0002CP0002CP0002 B13101 2' - 11"1' - 3"1' - 3"0"9' - 3"13' - 9" 11/01/17 09/01/17 5' - 6"6' - 9"12' - 6"2' - 5"2' - 2" ADDCBE ZEPHYR PASTRY CASEPOS AND SAFEESPRESSOHOPNITRO BACKBAR L FRONT BAR (PARTNER SIDE) 3 L Scale: 3/8" = 1'-0" 2 Scale: 3/8" = 1'-0" Y E W D K WOOD CLADDING P L 34 3333 1 MAD100 2 WOOD CLADDING 1 L I-5002 E 1220510894 QM 3 WD0073Q12205Q12205 Q14694 MAD100I-5002Q14694 I-5002 L 3 Z WD0073 E 0 A D6 4 L H E 1' - 6" N 6" I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T 2 H E I-5002 S 0 M 7 1 R OPEN 1 16 3 A 3 1 1C I-5005 STORE #:8123 OPEN10' - 6" OPEN PROJECT #:25450-048 ISSUE DATE: 11/1/17 5" 10' - 6" B/O CELING T DESIGNER: LISA MACEDA 9' - 0" B/O CEILING 9' - 0" B/O CEILING9' - 0" B/O CEILING 5" R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 7' - 6" B/O HEADER CHECKED BY: 7' - 6" T/O UPPER CUBBY7' - 6" T/O UPPER CUBBY Revision Schedule 2' - 10"2' - 10"2' - 10" 4' - 4 1/2" B/O SHELF 5' - 0" B/O UPPER CUBBY5' - 0" B/O UPPER CUBBY RevDateByDescription PL0003PL000313101 B CP0002CP0002CP0002CP0002 CP0002CP0002PL0003PL0003CP0002CP0002 CP0002CP0002B13101CP0002CP0002CP0002CP0002 CP0002CP0002WD0073WD0073 CP0002CP0002 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 3' - 4"5' - 1"2' - 8"6' - 8" B13101 2' - 8"4' - 0"2' - 8" 7' - 4"2' - 6" WOOD SLAT 6' - 5"2' - 0" HOPNITROMOPDT ESPRESSO DT WINDOW BEYOND DT POS NITROHOP SHEET TITLE: CUSTOMER COUNTERDT ESPRESSODT WINDOWDT POS 4567 Scale: 3/8" = 1'-0"Scale: 3/8" = 1'-0"Scale: 3/8" = 1'-0"Scale: 3/8" = 1'-0" INTERIOR ELEVATIONS 02'4'6' 3/8" = 1'-0" SCALE: Scale: 3/8" = 1'-0" SHEET NUMBER: I-2102 10/31/2017 6:22:32 PM 7 6 X1202-ESX1202-ESX1202-ESX1202-ESX1202-ESX1202-ESX1202-ESX1202-ESX1202-ESX1202-SGX1202-SGX1202-SGL11611X1202-ESX1202-ESX1202-ES X1202-SGX1202-SGX1202-SG 3 I-5002 INTERIOR ELEVATION NOTES SHEET NOTES 1.INSTALL NEW RESTROOM SIGNAGE AS INDICATED.A.REFER TO MANUFACTURERS INSTRUCTIONS SHIPPED WITH ARTWORK FOR INSTALLATION INSTRUCTIONS AND SPACING. 2.INSTALL WOOD TRIM AT OPENING AS INDICATED. B.INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE. RUN 3.EXISTING ELECTRICAL PANEL TO REMAIN.BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS, NOT BEHIND CABINETS. 6" OPEN 4.RELOCATED LOCATION OF ALL SWITCHING. 6" TO C.PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS R BEYOND NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING 5.RELOCATED EXISTING FIRE EXTINGUISHER. PAINTS. C 2017 STARBUCKS COFFEE COMPANY 6.INSTALL FULL HEIGHT FRP ON WALLS AT WORKROOM AS INDICATED.D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS OTHERWISE NOTED; STARBUCKS COFFEE 7.INSTALL EXIT/ EMERGENCY LIGHTS AS INDICATED.-ALL WOOD AND METAL SURFACES SHALL BE 9' - 0" B/O CEILING PAINTED SEMIGLOSS, OR EQUAL. COMPANY -ALL ACCENT AND TRIM PAINT TO BE SEMIGLOSS, 2401 UTAH AVENUE SOUTH 5' - 0" 5' - 0" OR EQUAL. -ALL WALL AND CEILING PAINTS TO BE EGGSHELL, SEATTLE, WASHINGTON 98134 OR EQUAL. (206) 318-1575 E.FOR PAINT AND WALL TREATMENT SCHEDULES, REFER TO THESE DRAWINGS AND SPECIFICATIONS ARE THE ALL FINISH PLAN. FOR GRAPHICS SCHEDULE, REFER TO CONFIDENTIAL AND SHALL REMAIN THE SOLE 2 THE FURNITURE, FIXTURES, AND EQUIPMENT PLAN. PROPERTY OF STARBUCKS CORPORATION, SW9138SW9138SW9138SW9138SW9138SW9138 WD0073WD0073B13101 13101 B B13101 13101WD0073WD0073 B WHICH IS THE OWNER OF THE COPYRIGHT IN 1 THIS WORK. THEY SHALL NOT BE 1 10753 G REPRODUCED (IN WHOLE OR IN PART), SHARED G10753 WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS RR VEST WEST RR VEST NORTHRR VEST EASTRR VEST SOUTH PROJECT WITHOUT THE PRIOR WRITTEN 4 123 Scale: 3/8" = 1'-0" Scale: 3/8" = 1'-0"Scale: 3/8" = 1'-0"Scale: 3/8" = 1'-0" CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 6 1146911469 QQ Design Forum 67 Q11469 6 Q11469L11649 E13682 Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 9 Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 I-5003 OPEN TO BEYOND OPEN Design Forum TO BEYOND Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 13' - 6" B/O ACT CEILING 9' - 10" B/O ACT CEILING 9' - 10" B/O ACT CEILING 11/01/17 09/01/17 E11083B14856E10110 14856109951146911469 B6PQQ6 11469 Q P10922 L P13149 L WATER FILTRATIONCOOLING FRIDGE Y 56 Scale:Scale: 3/8" = 1'-0" 3/8" = 1'-0" E W D K P L L E 3 L 11469 Q 3 Z E 0 5 6 A D6 I-5002 4 L 10 H 7 66 E I-5003 N 7 1' - 0" 11611 L I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 6 Z Q11469QQ1146911469 & , I-5002 MIN Q11469 A L T H E S 0 M 7 1 R 1 OPEN 2' - 0" 3 A 3 TO BEYOND 1' - 6" MIN 9 1 1C I-5003 STORE #:8123 OPEN PROJECT #:25450-048 TO ISSUE DATE: 11/1/17 BEYOND DESIGNER: LISA MACEDA 10698 E 13' - 6" B/O ACT CEILING R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: P10922 9' - 10" B/O ACT CEILING 9' - 10" B/O ACT CEILING 10995 P Revision Schedule RevDateByDescription 4' - 11" B/O MOP RACK C:\\Users\\zach.scholl\\Documents\\Starbucks_131st B14856P18743 E10293 13326 E 54 2 14856156991802911469 BEEQ 6 SHEET TITLE: 11104 E E10813 INTERIOR ELEVATIONS ICE MACHINE 3 - COMP SINK 8 3/8" = 1'-0" SCALE: Scale: 3/8" = 1'-0" 7 Scale: 3/8" = 1'-0" 02'4'6' SHEET NUMBER: Scale: 3/8" = 1'-0" I-2103 10/31/2017 6:22:52 PM SHEET NOTESINTERIOR ELEVATION NOTES A. 1.INSTALL NEW MANAGER'S DESK AND SHELVINGREFER TO MANUFACTURERS INSTRUCTIONS SHIPPED WITH AS INDICATED.ARTWORK FOR INSTALLATION INSTRUCTIONS AND SPACING. B. 2.EXISTING ELECTRICAL PANEL TO REMAIN.INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE. RUN 4 8 BACKBAR WALL TILE TO UNDERSIDE OF WALL CABINETS, 108091874411469 FAQ 53 I-5003 3.EXISTING CAMERA TO REMAIN. NOT BEHIND CABINETS. R C. 4.INSTALL FULL HEIGHT FRP ON NEW WALLS ATPAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS WORKROOM AS INDICATED.NATIONAL ACCOUNT "COLOR CODE" WHEN ORDERING C 2017 STARBUCKS COFFEE COMPANY PAINTS. 5.EXISTING EXIT/ EMERGENCY LIGHTS TO REMAIN. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS STARBUCKS COFFEE GC TO RE-PAINT SERVICE DOOR EXISTING COLOR. OTHERWISE NOTED; 6. -ALL WOOD AND METAL SURFACES SHALL BE COMPANY PAINTED SEMIGLOSS, OR EQUAL. 2401 UTAH AVENUE SOUTH -ALL ACCENT AND TRIM PAINT TO BE SEMIGLOSS, SEATTLE, WASHINGTON 98134 OR EQUAL. -ALL WALL AND CEILING PAINTS TO BE EGGSHELL, (206) 318-1575 OR EQUAL. THESE DRAWINGS AND SPECIFICATIONS ARE E. FOR PAINT AND WALL TREATMENT SCHEDULES, REFER TO CONFIDENTIAL AND SHALL REMAIN THE SOLE THE ALL FINISH PLAN. FOR GRAPHICS SCHEDULE, REFER TO PROPERTY OF STARBUCKS CORPORATION, THE FURNITURE, FIXTURES, AND EQUIPMENT PLAN. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED 9' - 10" B/O ACT CEILING WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION B14856F10605 1 62 F18106 NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES MANAGER'S DESK STARBUCKS TEMPLATE VERSION i2017.08.25 1 Scale: 3/8" = 1'-0" Design Forum Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 Design Forum Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 Q11469F11526 4 OPEN 3' - 9" TO BEYOND OPEN TO BEYOND 11/01/1709/01/17 L RD L Y E IN BOA 9' - 10" B/O ACT CEILING W OOK D 5' - 6" K P L 4' - 0" BULLET COAT H L E 3 C/O L C/O 3 Z E 0 A D6 4 L H 1485610820 BF E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L COAT HOOK T H E 2 Scale: 3/8" = 1'-0" S 0 M 7 1 R 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: INTERIOR ELEVATIONS 02'4'6' 3/8" = 1'-0" SCALE: Scale: 3/8" = 1'-0" SHEET NUMBER: I-2104 10/31/2017 6:23:02 PM ENLARGED RESTROOM PLAN NOTES A.DETAILS ARE FOR REFERENCE ONLY. B.ALL RESTROOM ACCESSORIES MOUNTING HEIGHTS TO MEET ACCESSIBILITY REQUIREMENTS PER STARBUCKS ACCESSIBILITY STANDARDS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND C. NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY R DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS C 2017 STARBUCKS COFFEE COMPANY TO BE TAKEN FROM DESIGNATED DATUM POINT. 11' - 9 1/4" STARBUCKS COFFEE D.DIMENSIONS ARE TO FACE OF FINISHED SURFACE. COMPANY E.PROVIDE BLOCKING AS REQUIRED. SEE SHEET I-5003 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 BABY CHANGING STATION NOTES THESE DRAWINGS AND SPECIFICATIONS ARE 1.CHANGING STATION IS TO BE INSTALLED PER CONFIDENTIAL AND SHALL REMAIN THE SOLE MANUFACTURERÓS INSTRUCTIONS. UNIT IS TO BE (N)MIRROR PROPERTY OF STARBUCKS CORPORATION, FASTENED TO STRUCTURE AT ALL SIX CHASSIS (N)HAND WHICH IS THE OWNER OF THE COPYRIGHT IN 9" ATTACHMENT POINTS. STANDARD INSTALLATION IS (N)SOAP DRYERTHIS WORK. THEY SHALL NOT BE (N)DIAPER ATTACHMENT TO WOOD STUDS AND/OR WOOD BLOCKING. DISPENSER REPRODUCED (IN WHOLE OR IN PART), SHARED CHANGING FOR NON-STANDARD FRAMING CONDITIONS OTHER THAN WITH THIRD PARTIES OR USED IN ANY MANNER STATION CONCRETE, USE TOGGLER SNAPTOGGLE HEAVY DUTY (N)WALL ON OTHER PROJECTS OR EXTENSIONS TO THIS TOGGLE BOLTS TO SECURELY ATTACH CHASSIS TO WALL. MOUNTED SINK PROJECT WITHOUT THE PRIOR WRITTEN FOR CONCRETE WALLS, USE FISCHER S-PLUG FIXINGS TO MEN 1' - 6" CONSENT OF STARBUCKS CORPORATION. 1' - 6" (N)36" (MIN) ANCHOR FASTENERS. SUBSTITUTION OF FASTENERS THESE DRAWINGS AND SPECIFICATIONS ARE RESTROOM (N)FLOOR HORIZONTAL GRAB OTHER THAN THE MANUFACTURER AND PRODUCT 1 INTENDED TO EXPRESS DESIGN INTENT FOR A DRAIN BAR SPECIFIED IS NOT ALLOWED WITHOUT PRIOR APPROVAL. PROTOTYPICAL STARBUCKS STORE (WHICH IS LOAD TEST AFTER INSTALLATION WITH 100 LB. WEIGHT FOR SUBJECT TO CHANGE AT ANYTIME) AND DO 15 MINUTES. I-4102.1 42 (N)EFFICIENT NOT REFLECT ACTUAL SITE CONDITIONS. SINGLE FLUSH NEITHER PARTY SHALL HAVE ANY OBLIGATION 5' - 2 1/4" 2.LOCATE STATION AS SHOWN TO ALLOW NECESSARY CLEARANCE TOILET W/FLUSH O (N)COAT HOOK NOR LIABILITY TO THE OTHER (EXCEPT STATED 3 FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL METER (DOOR MOUNTED) ABOVE) UNTIL A WRITTEN AGREEMENT IS NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. VERIFY ANY FULLYEXECUTEDBYBOTHPARTIES ALTERNATE LOCATION OR INSTALLATION APPROACH WITH STARBUCKS PROJECT LEAD. STARBUCKS TEMPLATE VERSION i2017.08.25 8 3/4" 1' - 6"1' - 6" Design Forum 2' - 9" 6" 6" Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 6" (N)48" (MIN) HORIZONTAL (N)TOILET PAPER (N)RESTROOM GRAB BARDISPENSERSIGNAGE Design Forum (N)SEAT COVER (N)18" (MIN) DISPENSERVERTICAL GRAB Engineering BAR 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 HALLWAY 6"2' - 9" 11/01/17 09/01/17 (N)48" (MIN) (N)18" (MIN) VERTICAL HORIZONTAL GRAB BARGRAB BAR 6" (N)SEAT COVER (N)TOILET PAPER DISPENSERDISPENSER L L Y E W D 6" K (N)RESTROOM P SIGNAGE L 8 3/4" L 1' - 6"1' - 6" E 3 (N)EFFICIENT SINGLE L 3 Z FLUSH TOILET E 0 W/FLUSH O METER A D6 4 5 L H (N)COAT HOOK E N (DOOR MOUNTED) I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z (N)36" (MIN) I-4102.1 & 86 , HORIZONTAL GRAB BAR A L T H E 7 S 0 M 5' - 6 3/4" WOMEN (N)FLOOR 7 1 R DRAIN RESTROOM 1 3 A 3 1' - 6"1' - 6" 1 1C (N)WALL MOUNTED STORE #:8123 SINK (N)DIAPER (N)HAND 9"PROJECT #:25450-048 CHANGING STATION DRYER (N)SOAP DISPENSER ISSUE DATE: 11/1/17 (N)MIRROR DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription 11' - 9 1/2" C:\\Users\\zach.scholl\\Documents\\Starbucks_131st ENLARGED RESTROOM PLAN SHEET TITLE: 1 N Scale: 3/4" = 1'-0" ENLARGED RESTROOM PLAN 01'2'3' 3/4" = 1'-0" SCALE: Scale: 3/4" = 1'-0" SHEET NUMBER: I-4102 10/31/2017 6:23:06 PM ENLARGED 7 RX1203 RX12037 7RX1203 RESTROOM PLAN NOTES 2 SW6165X1202-SGX1202-SGX1202-SGWD0073WD0073Q18311 5 A.DETAILS ARE FOR REFERENCE ONLY. 3' - 3" 18311SW6165 Q 2 18311SW6165 Q 1' - 6"1' - 6" 2OF 2' - 3" WALL B.ALL RESTROOM ACCESSORIES MOUNTING HEIGHTS TO MEET ACCESSIBILITY REQUIREMENTS PER STARBUCKS ACCESSIBILITY STANDARDS. C.GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND 2 NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY 4 R DISCREPANCIES PRIOR TO CONSTRUCTION. ALL I-5003 14359 L DIMENSIONS TYP C 2017 STARBUCKS COFFEE COMPANY TO BE TAKEN FROM DESIGNATED DATUM POINT. D.DIMENSIONS ARE TO FACE OF FINISHED SURFACE. STARBUCKS COFFEE 3 F14350 E.PROVIDE BLOCKING AS REQUIRED. SEE SHEET I-5003 I-5003 COMPANY 6" 2401 UTAH AVENUE SOUTH BABY CHANGING STATION NOTES 10769 E SEATTLE, WASHINGTON 98134 P10116 (206) 318-1575 1.CHANGING STATION IS TO BE INSTALLED PER 10859 E MANUFACTURERÓS INSTRUCTIONS. UNIT IS TO BE THESE DRAWINGS AND SPECIFICATIONS ARE FASTENED TO STRUCTURE AT ALL SIX CHASSIS 9' - 0" B/O CEILING9' - 0" B/O CEILING9' - 0" B/O CEILING CONFIDENTIAL AND SHALL REMAIN THE SOLE ATTACHMENT POINTS. STANDARD INSTALLATION IS 8" PROPERTY OF STARBUCKS CORPORATION, 6' - 6" ATTACHMENT TO WOOD STUDS AND/OR WOOD BLOCKING. WHICH IS THE OWNER OF THE COPYRIGHT IN FOR NON-STANDARD FRAMING CONDITIONS OTHER THAN THIS WORK. THEY SHALL NOT BE 6' - 6" B/O TRIM6' - 6" B/O TRIM CONCRETE, USE TOGGLER SNAPTOGGLE HEAVY DUTY 5' - 0" 6' - 10" C/O SCONCE REPRODUCED (IN WHOLE OR IN PART), SHARED TOGGLE BOLTS TO SECURELY ATTACH CHASSIS TO WALL. WITH THIRD PARTIES OR USED IN ANY MANNER 4' - 0"4' - 0" FOR CONCRETE WALLS, USE FISCHER S-PLUG FIXINGS TO C/O LEED DISK ON OTHER PROJECTS OR EXTENSIONS TO THIS ANCHOR FASTENERS. SUBSTITUTION OF FASTENERS PROJECT WITHOUT THE PRIOR WRITTEN 2' - 9"2' - 9" OTHER THAN THE MANUFACTURER AND PRODUCT ALIGN ALIGNALIGN CONSENT OF STARBUCKS CORPORATION. SPECIFIED IS NOT ALLOWED WITHOUT PRIOR APPROVAL. THESE DRAWINGS AND SPECIFICATIONS ARE 3' - 4" B/O MIRROR LOAD TEST AFTER INSTALLATION WITH 100 LB. WEIGHT FOR INTENDED TO EXPRESS DESIGN INTENT FOR A 15 MINUTES. 3' - 2" B/O HAND DRYER PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 2.LOCATE STATION AS SHOWN TO ALLOW NECESSARY CLEARANCE 10384 E 6 1310110179 BE 4 NOT REFLECT ACTUAL SITE CONDITIONS. 1310110756131011009910172 BF3B6EE 6 1FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL I-5003 NEITHER PARTY SHALL HAVE ANY OBLIGATION NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. VERIFY ANY NOR LIABILITY TO THE OTHER (EXCEPT STATED ALTERNATE LOCATION OR INSTALLATION APPROACH WITH ABOVE) UNTIL A WRITTEN AGREEMENT IS MEN'S RESTROOM - SOUTH MEN'S RESTROOM - EAST MEN'S RESTROOM- NORTH STARBUCKS PROJECT LEAD. FULLYEXECUTEDBYBOTHPARTIES 3 2 1 Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0" STARBUCKS TEMPLATE VERSION i2017.08.25 7 SHEET NOTES Q183112X1202-SGX1202-SGX1202-SG5WD0073WD0073SW6165RX1203 2 RX1203Q18311SW6165 7 2 RX1203Q18311SW6165 7 3' - 3" Design Forum 1.INSTALL ADA-COMPLIANT ANTI-SCALD DRAIN PIPE INSULATION SYSTEM. PRODUCT SHALL BE SYSTEM DESIGNED AND MANUFACTURED SPECIFICALLY FOR THIS Architects Inc. PURPOSE. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 2 Cincinnati, OH 45203Architect In Charge INSTALL WALL TILE AT RESTROOMS AS INDICATED. SEE 2. Tel: (513) 421-2210License: AR19700147 I-5003 DETAIL 1/I-5003 TYP C 3.COAT HOOK MOUNTED @ OF DOOR AS SHOWN 4' - 0" A.F.F. L Design Forum 4.INSTALL NEW RESTROOM WALL SCONCE AS INDICATED. Engineering RELOCATE EMERGENCY LIGHTS AS INDICATED. 5. 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer 6.ALIGN GROUT JOINTS OF WALL TILE AND TILE BASE. License: PE10504904 Tel: (513) 421-2210 10769 E 7.INSTALL SCHLUTER TRIM AS INDICATED. E10859 E10862 9' - 0" B/O CEILING9' - 0" B/O CEILING9' - 0" B/O CEILING 8" 6' - 6" B/O TRIM6' - 6" B/O TRIM6' - 6" B/O TRIM 4' - 0" 2' - 9"2' - 9" ALIGN ALIGN ALIGN 11/01/17 09/01/17 PX0101B13101 L 6 E10172E10099B13101F10756 63 B13101 6 L Y E W MEN'S RESTROOM - WESTWOMEN'S RESTROOM - NORTHWOMEN'S RESTROOM - EAST D 456 K Scale:Scale:Scale: 1/2" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-0" P L L E 3 7 L 3 Z E Q18311RX1203SW6165 2 0 2 SW616518311 Q 2' - 3" OF 1' - 6"1' - 6" A D6 WALL 4 L H 7 E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt X1203 R Z & , A L T 4 H E L14359 S 0 M 7 1 R 1 3 A 3 1 1C 3 STORE #:8123 6" I-5003 14350 F PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 9' - 0" B/O CEILING9' - 0" B/O CEILING CHECKED BY: Revision Schedule 6' - 6" B/O TRIM6' - 6" B/O TRIM 5' - 0" 6' - 10" C/O SCONCE RevDateByDescription 4' - 0" C/O LEED DISK 2' - 9"2' - 9" ALIGN ALIGN C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 3' - 4" B/O MIRROR 3' - 2" B/O HAND DRYER 4SHEET TITLE: 11017913101610384 EBE B13101E10862PX0101 6 I-5003 ENLARGED RESTROOM ELEVATIONS WOMEN'S RESTROOM - SOUTHWOMEN'S RESTROOM - WEST 78 1/2" = 1'-0" SCALE: 01'2'4' Scale:Scale: 1/2" = 1'-0" 1/2" = 1'-0" SHEET NUMBER: Scale: 1/2" = 1'-0" I-4102.1 10/31/2017 6:23:13 PM METAL STUDS (PER WALL TYPE) ROOF STRUCTURE @ 16" O.C. TO UNDERSIDE OF R SLIP TRACK ROOF STRUCTURE, TO MINIMUM CONNECTION OF 6" ABOVE SUSPENDED CLG C 2017 STARBUCKS COFFEE COMPANY WOOD CLADDING 20 GA. 3 5/8" MTL STUD BRACING OR TO UNDERSIDE OF EXIST NEED FINISH: WD0073 @ 48" O.C.. ATTACH TO PARTITION 3/4" GAP SOFFIT OR CLG. MTL STUDS FRAMING W/ 3/8" PAN HEAD EXIST ROOF TO MEET I.C.B.O. #1715 OF EQ. STARBUCKS COFFEE LED STRIP LIGHT TYPE "S" SCREWS. USE LATERAL STRUCTURE MIN. BRACING WHEN PARTITION FRAMING COMPANY MENU BOARD FRAME 2' - 5 1/2" DOES NOT ATTACH TO ROOF NAIL STUD RUNNER TO FLRATTACH METAL FRAMING 2401 UTAH AVENUE SOUTH STRUCTURE. W/ HILTI NK FASTENERS,TO UNDERSIDE OF EXIST SEATTLE, WASHINGTON 98134 1 1/8" MINIMUM PENETRATION @STRUCTURE SUSPENDED CLG, AS OCCURS 32" O.C. MAX. (206) 318-1575 BACKBAR SHELF (I.C.B.O. #2388) THESE DRAWINGS AND SPECIFICATIONS ARE 48" 2" CONFIDENTIAL AND SHALL REMAIN THE SOLE MENU BOARD PROPERTY OF STARBUCKS CORPORATION, HARDWARE 7WHICH IS THE OWNER OF THE COPYRIGHT IN EXIST CONC SLAB 5/8" GYP. BD. THIS WORK. THEY SHALL NOT BE 5/8" G.W.B. TYPE "X" BOTH I-5012 ANGLE BRACE SIDES TO MINIMUM OF 6"REPRODUCED (IN WHOLE OR IN PART), SHARED @ 4'-0" O.C. MENU BOARD ABOVE CLG. TYPE "S" DRY-WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS WALL SCREWS AT 8" O.C. TO PROJECT WITHOUT THE PRIOR WRITTEN VERTICAL EDGES AND 12" O.C. TO INTERMEDIATE STUDS.CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE STAGGERING JOINTS 24" O.C., LED STRIP LIGHT 3 5/8" 20 GA. MTL STUD INTENDED TO EXPRESS DESIGN INTENT FOR A EACH SIDE. SECTION @ FLOORSECTION @ CEILING PROTOTYPICAL STARBUCKS STORE (WHICH IS GREEN BOARD TILE SUBJECT TO CHANGE AT ANYTIME) AND DO SUBSTRATE BY G.C. NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NEW PARTITION WALL TO STRUCTUREDETAIL AT 3 5/8" METAL STUDS TO DECK BACKBAR TILE @ EXPOSED WALL NOR LIABILITY TO THE OTHER (EXCEPT STATED 23 SURFACE FROM B/O WOOD SOFFIT Scale: 1" = 1'-0"Scale: 1/2" = 1'-0" ABOVE) UNTIL A WRITTEN AGREEMENT IS BACKSPLASH FULLYEXECUTEDBYBOTHPARTIES SOLID SURFACE 9' - 6" (B/O WOOD SOFFIT) STARBUCKS TEMPLATE VERSION i2017.08.25 COUNTERTOP W/ INTEGRAL BACKSPLASH 2'-10" A.F.F. Design Forum 8' - 0" (T/O BACKBAR SHELF) (BACKBAR COUNTERTOP) Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman ATTACH METAL FRAMING ELECTRICAL OUTLET 1 Cincinnati, OH 45203Architect In Charge 6' - 0" (B/O BACKBAR SHELF) TO UNDERSIDE OF EXIST Tel: (513) 421-2210License: AR19700147 STRUCTURE 2 METAL STUDS (PER WALL TYPE) @ 16" O.C. TO UNDERSIDE OF Design Forum 3 2' - 2" ROOF STRUCTURE, TO MINIMUM 4 OF 6" ABOVE SUSPENDED CLG Engineering OR TO UNDERSIDE OF EXIST ATTACH STUD TO BEAM W/ EXIST ROOF LEG BASE SOFFIT OR CLG. MTL STUDS 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE KICKER AS REQ'D. STRUCTURE 20 GA. 3 5/8" MTL STUD BRACING Cincinnati, OH 45203Professional Engineer TO MEET I.C.B.O. #1715 OF EQ. License: PE10504904 Tel: (513) 421-2210 @ 48" O.C.. ATTACH TO PARTITION 3-5/8" 20GA METAL METAL STUDS (PER WALL TYPE) FRAMING W/ 3/8" PAN HEAD STUDS. @ 16" O.C. TO UNDERSIDE OF TYPE "S" SCREWS. USE LATERAL ROOF STRUCTURE, TO MINIMUM NOTES: BRACING WHEN PARTITION FRAMING OF 6" ABOVE SUSPENDED CLG DOES NOT ATTACH TO ROOF OR TO UNDERSIDE OF EXIST 1 1'-7" AFF (CW SUPPLY) STRUCTURE. SOFFIT OR CLG. MTL STUDS TO MEET I.C.B.O. #1715 OF EQ. 2 1'-6" AFF (CWF SUPPLY) SUSPENDED CLG, AS OCCURS SEE RCP FOR HEIGHT NAIL STUD RUNNER TO FLR 1'-5" AFF (HW SUPPLY) 3 6" W/ HILTI NK FASTENERS, Min 1 1/8" MINIMUM PENETRATION @ VARIES: 1/4" PER FOOT FALL (ABS 4 32" O.C. MAX. 5/8" GWB TYPE "X" BOTH NEW CLG. 2" WASTE LINE)2" (I.C.B.O. #2388) SIDES TO MINIMUM OF 6" 11/01/1709/01/17 ABOVE CLG. TYPE "S" DRY- VARIES W/ DOORS EXIST CONC SLABWALL SCREWS AT 8" O.C. TO VERTICAL EDGES AND 12" O.C. TO INTERMEDIATE STUDS.5/8" GYPSUM BOARD. METAL STAGGERING JOINTS 24" O.C.,TRIM, FLOAT AND TAPE. L EACH SIDE.BOTTOM ELEVATION VARIES - L SECTION @ FLOORSECTION @ CEILING SEE PLAN. Y E W D SECTION AT BACKBAR WALLNEW PARTITION WALL 6" ABOVE CEILINGHEADER DETAIL K 145 P Scale:Scale:Scale: 3/4" = 1'-0" 1" = 1'-0" 1 1/2" = 1'-0" L L E 3 L 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 ESPRESSO SHROUD M 7 CONTINUOUS TOP CLEAT GYP BOARD 1 R WALL TYPE FASTENER SCHEDULE 1 1" X 2" CONT. GALV. STL. ANGLE SECURED TO CABINET W/ 3 A 3 STUD WALL BLOCKING REQUIREMENTS: (2) 1-1/2" #10 SCREWS WALL TYPEWALL BLOCKINGFASTENERSNOTES 1 1C WOOD STUD WALLS REQUIRE MIN. 2"X6" EVERY 16" OC SOLID SURFACE ESPRESSO #8 X3" (75MM) WD X WOOD FRAMEREFER TO BLOCKING REQUIREMENTS (50MMX150MM) WOOD BLOCKING SECURED OR EQUIVALENT FLUSH TO STUD FACE WITH (3) 10D NAILS (OR #6CT. X11/4" (30MM) MTL/WD STORE #:8123 X REFER TO BLOCKING REQUIREMENTS METAL FRAME OR EQUIVALENT EQUIVALENT) CONTINUOUS BLOCKINGHANGING PROJECT #:25450-048 MIN. 5/16"X3" (8MMX75MM) CMUSPACE PER DETAIL THIS SHEET TAPCON OR EQUIVALENT CABINET METAL STUD WALLS REQUIRE MIN. 2"X6" 2'-10" AFF (COUNTERTOP) ISSUE DATE: 11/1/17 MIN. 1/4"X3" (7MMX75MM) CONCRETESPACE PER DETAIL THIS SHEET (50MMX150MM) WOOD BLOCKING SECURED SLEEVE ANCHOR OR EQUIVALENT DESIGNER: LISA MACEDA R FLUSH TO STUD FACE WITH MIN. (3) #6 CT. MIN. 1/4"X1" (7MMX25MM) SPACE PER DETAIL THIS SHEET LEED AP: BRICK ANCHOR BOTTOM CLEAT TO AVOID SETTING ANCHORS IN MORTAR JOINTS WEDGE ANCHOR OR EQUIVALENT 1.25" (30MM) SCREWS (OR EQUIVALENT) PRODUCTION DESIGNER: PETER CHEETHAM CASEWORK PANELS ATTACHED TO WALL W/ 1-3/4" #10 SCREWS CHECKED BY: DIE WALL WITH CLEAT SYSTEM ANCHOR CABINET CLEAT VARIES 2'-2" AFF (ELEC. J-BOXES) VERIFY IN-WALL BLOCKING OR W/ 1-1/2" LONG ALL PLUMBING LINES TO BE ENSURE SOLID ATTACHMENT MURAKOSHI BOLTS EQEQEQEQEQEQEQ Revision Schedule MOUNTED 1" (NOMINAL) FROM (6) FASTENERS EVENLY SPACED 3" (75MM) STUD(S) OF CLEAT TO WALL AT EACH MINIMUM OF (2) PER 1'-7" AFF (CW Supply) WALL FOR CLEANING MINIMUM. ACROSS OPENING (TYPICAL AT ALL STUD CABINET BAY RevDateByDescription 1'-6" AFF (CWF Supply) CABINETS) 6" FRONT BAR DIE WALL CENTER FASTENERS ANCHOR CABINET TO CENTER FASTENERS VERTICALLY ON WALL CLEAT 1'-5" AFF (HW Supply) @ BARISTA VERTICALLY ON WALL CLEAT CLEAT W/ 1-1/2" LONG SOLIDLY ATTACHED TO WALL. SEE "WALL TYPE ANCHOR BOTTOM VARIES; 1/4" PER FT. FALL C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SOLIDLY ATTACHED TO WALL. MURAKOSHI BOLTS BLOCKING TO WALL W/ (2) 1-FASTENER SCHEDULE" FOR SPECIFICATION. CONTINUOUS METAL ANGLE (ABS 2" WASTE LINE) SEE SCHEDULE "WALL TYPE MINIMUM OF (2) PER 1/4" #10 SCREWS EVERY 16" MOUNTED TO PLYWOOD REMOVABLE CABINET BACK PANELADJUSTABLE SHELF (IF APPLICABLE) FASTENER SCHEDULE" FOR CABINET BAY OC STAGGERED WALL, UNDER FINISH PANELS SPECIFICATIONS. SIMILAR FASTENERS AT EACH STUD LOCATION FRP INT SURFACE TILE BASE SHEET TITLE: ACROSS OPENING (TYPICAL AT ALL CABINETS) 1"X4" (25MM X 100MM) 6" ADJUSTABLE METAL LEGSFURRING STRIP OR METAL TRIM TO BE PAINTED CONSTRUCTION EQUIVALENT DETAILS AS SHOWN SCALE: WALL SECTION AT DIEWALLANCHOR DETAILUPPER CABINET ATTACHMENT 678 SHEET NUMBER: Scale: 1" = 1'-0"Scale: 3" = 1'-0"Scale: 1" = 1'-0" I-5001 10/31/2017 6:23:19 PM 1/8"DIA STEEL GALVANIZE RECESSED CAN ROD SPACED @ 4'-0" O.C. LIGHT (TYP.) MAX. SECURED TO STEEL TRUSS ABOVE W/ SHIELDS C 5 L I-5001 2X4FT 61X122CM; CIRRUS SECOND PLYWOOD BACKING R LOOK: 511 WHITE; 6"X48" LINEAR PLANK LOOK PANEL 6" C 2017 STARBUCKS COFFEE COMPANY WOOD CLADDING 10'- 6" AFF AT SOFFIT B/O ACT CEILING STARBUCKS COFFEE 9'- 6" AFF B/O WOOD SOFFIT COMPANY METAL ANGLE METAL ANGLE 2401 UTAH AVENUE SOUTH 6" 20 GA 3-5/8" MTL. SEATTLE, WASHINGTON 98134 STUDS ON 16" O.C. 1' - 0" 9'- 0" AFF WOOD SOFFIT BLOCKING AS (206) 318-1575 B/O ACT CEILING MITER JOINT FINISH: WD0073 REQUIRED THESE DRAWINGS AND SPECIFICATIONS ARE 20 GA 3-5/8" MTL. 9'- 6" AFF CONFIDENTIAL AND SHALL REMAIN THE SOLE STUDS ON 16" O.C. B/O WOOD SOFFIT PROPERTY OF STARBUCKS CORPORATION, ACT CEILING WHICH IS THE OWNER OF THE COPYRIGHT IN WOOD SOFFIT 5/8" TYPE "X" GYP. BD. HEADER 5/8" TYPE CEMENT BOARD THIS WORK. THEY SHALL NOT BE PLYWOOD ON 20 GA 3-5/8" "X" GYP. BD. ON 20 GA 3-5/8" REPRODUCED (IN WHOLE OR IN PART), SHARED MTL STUD. @ 16" O.C. MTL STUD. @ 16" O.C. TILE FINISH AS WITH THIRD PARTIES OR USED IN ANY MANNER FINISH: WD0073 PAINT FINISH: SW7005 SCHEDULED ON OTHER PROJECTS OR EXTENSIONS TO THIS 20 GA 3-5/8" MTL. PROJECT WITHOUT THE PRIOR WRITTEN LED STRIP LIGHT STUDS ON 16" O.C. CONSENT OF STARBUCKS CORPORATION. BACKBAR TILES BLOCKING AS THESE DRAWINGS AND SPECIFICATIONS ARE REQUIRED BLACK SCHLUTER QUADEC- INTENDED TO EXPRESS DESIGN INTENT FOR A 1 1/2" AGR-GRAPHITE INSTALLED PER PROTOTYPICAL STARBUCKS STORE (WHICH IS 4" 8'- 0" AFF 1' - 5" 4"2' - 8 3/4" MANUFACTURER SUBJECT TO CHANGE AT ANYTIME) AND DO B/O HEADER RECOMMENDATIONS BLACK NOT REFLECT ACTUAL SITE CONDITIONS. FINISH ONLY NO NEITHER PARTY SHALL HAVE ANY OBLIGATION TYP. TILE GROUT THICKNESS 3" SUBSTITUTIONS LED STRIP LIGHTNOR LIABILITY TO THE OTHER (EXCEPT STATED 1/16" CUSTOM BUILDING ABOVE) UNTIL A WRITTEN AGREEMENT IS PRODUCTS CHARCOAL **NO FULLYEXECUTEDBYBOTHPARTIES SUBSTITUTIONS** WALLCOVERING FINISH AS SCHEDULED STARBUCKS TEMPLATE VERSION i2017.08.25 SOFFIT CONSTRUCTION DETAILHEADER AT DTCOVE DETAIL 123 Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 3" = 1'-0" Design Forum Architects Inc. 5 700 W. Pete Rose Way, Suite 460Donald J. Rethman I-5001 Cincinnati, OH 45203Architect In Charge 5 Tel: (513) 421-2210License: AR19700147 I-5001 ACT CEILING 5 Design Forum I-5001 ACT CEILING 6" 5 BRACE AS 10'- 6" AFF Engineering I-5001 REQUIRED 6" B/O ACT CEILING 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer 10'- 6" AFF License: PE10504904 Tel: (513) 421-2210 B/O ACT CEILING METAL ANGLE ACT CEILING ACT CEILING GYP.BOARD CEILING 20 GA 3-5/8" MTL. 6" 6" PAINT FINISH: SW7005STUDS ON 16" O.C. METAL ANGLE METAL ANGLE 9'- 10" AFF 13'- 0" AFF B/O ACT CEILING B/O ACT CEILING ACT CEILING 6" METAL ANGLE METAL ANGLE 9'- 6" AFF 10'- 6" AFF 3BLOCKING AS B/O GYP.BD. CEILING B/O ACT CEILING 11/01/1709/01/17 REQUIRED I-5002 FRP FINISH AS 20 GA 3-5/8" MTL. SCHEDULED STUDS ON 16" O.C. 20 GA 3-5/8" MTL. WALLCOVERING FINISH STUDS ON 16" O.C. FRP FINISH AS WALLCOVERING FINISH AS SCHEDULED L SCHEDULED AS SCHEDULED 20 GA 3-5/8" MTL. L 9'- 9" AFF 5/8" TYPE "X" GYP. BD. STUDS ON 16" O.C. 1 1/2" 5/8" TYPE "X" GYP. BD. Y B/O GYP.BD.SOFFIT GYP. BOARD ON 20 GA 3 5/8" MTL E GYP. BD. HEADER 5/8" TYPE ON 20 GA 6" MTL STUD. @ 16" O.C. LED STRIP LIGHT W "X" GYP. BD. ON 20 GA 3-5/8" STUD. @ 16" O.C. GYP. BD. HEADER 5/8" TYPE D MTL STUD. @ 16" O.C.K PAINT FINISH AS WOOD BLOCKING "X" GYP. BD. ON 20 GA 3-5/8" 4" WOOD BLOCKING SCHEDULEDAS REQUIRED P L MTL STUD. @ 16" O.C. AS REQUIRED WALLCOVERING PAINT FINISH: SW7005 L 6" E 3 7'- 3" AFF FINISH AS SCHEDULED L 3 7'- 3" AFF B/O HEADER Z 9'- 10" AFF E COUNTERSUNK 0 B/O HEADER COUNTERSUNK B/O HEADER A D6 SCREW 1/2" SOLID WOOD SCREW 4 15 1/2" SOLID WOOD PAINTED TO MATCH L H (E) ACT CEILING I-5005 PAINTED TO MATCH WALLCOVERING E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt WALLCOVERING Z & , A L HEADER AT CAFEWATER FILTRATION HEADERHEADER AT RESTROOM VESTIBULEHEADER AT WORKROOM T H E 4567 Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0" S 0 M 7 1 R 1 3 A #10 X 1-1/2" WOOD 3 9 SCREWS CENTERED 1 1C I-5002 ON LOWER CLEAT STUD STORE #:8123 5" PROJECT #:25450-048 10 ISSUE DATE: 11/1/17 BLOCKING I-5002 FASTEN BLOCKING TO EACH DESIGNER: LISA MACEDA R STUD WITH WOOD INSERTS & LEED AP: (3) TEK SCREWS PRODUCTION DESIGNER: PETER CHEETHAM 1-3/4" X 3-1/2" SHIM 3"X3/4"X32" CLEAT 5/8" GYP. CHECKED BY: FASTEN TO WALL WITH (3) FASTENERS TO C OF SCREW (7) #8 TEK SCREWS @ NOTES: L MATCH CLEAT WALL Revision Schedule 41/2" O.C. ANCHORS 1.45 LBS DEAD LOAD PER OPENING RevDateByDescription FOR LIQUID STORAGE OVER AND ABOVE THE CASEWORK ITSELF. SECTION#10 X 1-1/2" WOODELEVATION NOTES: SCREWS C OF SCREW (6) #10 X 2 1/2" L C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 2.A LIVE LOAD OF A PARTNER CENTERED ON TEK SCREWS AT 1. 45 LBS DEAD LOAD PER OPENING EITHER PULLING AND OR LOWER SHIM 5" O.C. FOR LIQUID STORAGE OVER AND CLIMBING ON THE CASEWORK. ABOVE THE CASEWORK ITSELF. NOTES: SHEET TITLE: 2. A LIVE LOAD OF A PARTNER EITHER 1. 45 LBS DEAD LOAD PER OPENING FOR LIQUID STORAGE OVER 2"X4" BLOCKING PULLING AND OR CLIMBING ON THE CONSTRUCTION AND ABOVE THE CASEWORK ITSELF. CASEWORK. 5" X 3/4" X 32" CLEAT DETAILS 2. A LIVE LOAD OF A PARTNER EITHER PULLING AND OR CLIMBING ON THE CASEWORK. AS SHOWN SCALE: SHEET NUMBER: BLOCKING AT CASEWORKCLEAT TO FRAMECLEAT TO WOOD BLOCKINGBLOCKING TO METAL STUD 891011 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" I-5002 10/31/2017 6:23:25 PM C L LOCATE AND MOUNT OF WALL TO STUD EQEQ3/4" MEDEX NOTE: INSTALL DIAPER CHANGING PRE DRILLED PER STATION PER MANUFACTURE SPECIFICATIONSMANUFACTURERS SCHEMATIC 2' - 10 1/4" 3' - 0" 2' - 10" 4'-6" AFF CEILING 2 1/4" 2 I-5003 R 6 1/4" 8 1/4" PAINT FINISH C 2017 STARBUCKS COFFEE COMPANY HAND DRYER INSTALLED PER AS SCHEDULED 1' - 5" 1' - 8"MFR SPEC TO MEET ANSI/ADA Q18311 6 1/4" ACCESSIBLE STANDARDS STARBUCKS COFFEE TILE - OLIVE DRAB BURLAP COMPANY TEXTURE - 11 3/4" SCHLUTER JOLLY A 100 ACG 12X24IN 2401 UTAH AVENUE SOUTH 8' - 6" 2 1/4" INSTALLED PER 300X600MM SEATTLE, WASHINGTON 98134 MANUFACTURER NOTE: DETAIL FOR DESIGN INTENT ONLY. 4' - 0" RECOMMENDATIONS. (206) 318-1575 3'-2" AFF 1"RADIUS MOUNTING HARDWARE AND DETAILED 3' - 10 3/4" INSTALLATION INSTRUCTIONS PROVIDED BY THESE DRAWINGS AND SPECIFICATIONS ARE 3/4" FIRE-TREATED PLYWOOD MANUFACTURER AND INCLUDED WITH BABY CONFIDENTIAL AND SHALL REMAIN THE SOLE SCHEDULED WALL TILE 9' - 0" (B/O GYP.BD.CEILING) BACKER PANEL ATTACHED TO CHANGING STATION. NOTE: FASTENERS MUST PENETRATE 3 PROPERTY OF STARBUCKS CORPORATION, BACK OF METAL STUDS 6' - 6" (B/O TRIM) SUBSTRATES WHICH IS THE OWNER OF THE COPYRIGHT IN AND FULLY ENGAGE WALL STUDS TO SUPPORT2'-6" AFF THIS WORK. THEY SHALL NOT BE 33" ABOVE FLOOR MAX B13101 250 POUNDS PER MANUFACTURERS REPRODUCED (IN WHOLE OR IN PART), SHARED TILE BASE - RECOMMENDATIONS WITH THIRD PARTIES OR USED IN ANY MANNER WALL FINISH AS SCHEDULED GRAPHITE - ON OTHER PROJECTS OR EXTENSIONS TO THIS 6X12IN BASE TILE PROJECT WITHOUT THE PRIOR WRITTEN 150X300MM CONSENT OF STARBUCKS CORPORATION. 6" THESE DRAWINGS AND SPECIFICATIONS ARE EQUIPMENT MOUNTING HEIGHTDIAPER CHANGING DETAIL 3-5/8" METAL STUDS INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO WALL TILE PATTERN AT RESTROOMTRIM DETAIL @ RESTROOMWALL MOUNTED BABY CHANGING EQUIPMENT DETAILSHAND DRYER BLOCKING NOT REFLECT ACTUAL SITE CONDITIONS. 1234 NEITHER PARTY SHALL HAVE ANY OBLIGATION Scale: 1/2" = 1'-0"Scale: 12" = 1'-0"Scale: 3/4" = 1'-0"Scale: 1 1/2" = 1'-0" NOR LIABILITY TO THE OTHER (EXCEPT STATED FRAME ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES 1' - 0" (305 MM)3' - 0" (915 MM)1' - 0" (305 MM) 1/2" (100 MM) DIA. INSULATED WATER *CLEAR*CLEAR STARBUCKS TEMPLATE VERSION i2017.08.25 LINE TO CHILLED WATER TOWER AT COLD BEVERAGE MIRROR LOW VOLTAGE CABLE BUNDLES STATION Design Forum BACK WALL 3 MUSIC2 SECURITY1 POS W FILTERED COLD WATER WATER SUPPLY PLAY NETWORKSECURITY PANELHIGH SPEED INTERNET . Architects Inc. CHILLER FOR CHILLER SPEAKERSFUTURE USEDEMARC EXTENSION È" 9.5mm 700 W. Pete Rose Way, Suite 460Donald J. Rethman --------------------------------------POS LAN Cincinnati, OH 45203Architect In Charge INDIRECT LINE " 13mm *CLEARANCE Tel: (513) 421-2210License: AR19700147 --------------------------------------DT TIMER FROM WATER REQUIREMENT (3) 2" (50 MM) Ø SLEEVES FOR CHILLER TO FLOOR SHOWN IS NOT LOW VOLTAGE CABLE BUNDLES SINK REQUIRED BELOW Design Forum MOUNTED TO (2) UNISTRUTS EMS DATA CONCENTRATOR AT 84" MOUNTING HEIGHT NOTE:STATION REQUIRES FLOOR SINK WITHIN 120" (3050 MM) (2130 MM) A.F.F. ALLOW 2" OF CHILLER (TYP.) S ADJACENCY. SEE PLUMBING PLAN FOR FINAL LOCATION. (50 MM) MIN. CLEAR ABOVE. CEILING Engineering DEMARC, IF REQUIRED DATA RACK WALL MOUNTED TO 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE ABOVE CHILLER BRACKET Cincinnati, OH 45203Professional Engineer STRUCTURE BY STARBUCKS WIRELESS MODEM AT 84" License: PE10504904 Tel: (513) 421-2210 VENDOR. GROUND RACK PER (2130 MM) A.F.F. STARBUCKS VENDOR STAINLESS CEILING MFR'S ASSEMBLY INSTRUCTIONS. TO DETERMINE OPTIMAL DEVICE STEEL CHANNEL SEE DATA RACK EQUIPMENT LOCATION. FRAME MIRROR SCHEDULE BELOW FOR LIST OF INSULATED WATER SHELVING EQUIPMENT INCLUDED WITHIN. LINE ROUTE AS AMPLIFIER (FURNISHED BY OWNER, POWER & DATA RECEPTACLES AT REQUIRED. INSTALLED WITH SPEAKER SYSTEM BY 69 1/2" (1765 MM) A.F.F. TO CENTER GC) ON 14" (355 MM) DEEP SHELF. OF GROUPING. SEE NOTE 'E' MIN. CLEAR CHILLER ABOVE FOR DESCRIPTION. 1' - 6" (460 MM) S MUSIC PLAYER SECURITY MONITOR MOUNTED MIN. 44" X 100" (1120 ON MONITOR ARM (ATTACHED TO DUPLEX RECEPTACLE FOR MUSIC T MM X 2540 MM) 5/8" BACKER BOARD). SYSTEM AT 60" (1525MM) A.F.F. 11/01/1709/01/17 FIRE-PROOF TTWALL HANGER DEDICATED DUPLEX RECEPTACLES OFFICE PC PLYWOOD BACKER FOR WORKSTATION @ 36" (915MM) 2-1/8" to 2-3/4" FASTENED TO BACK OF MIRROR DUPLEX RECEPTACLE A.F.F. STRUCTURE FOR WORKSTATION @ PRINTER 55 to 70mm S 36" (915MM) A.F.F. UPS L CHILLER BRACKET DATA RACK. L MOUNTED TO WALL WALL MOUNT OPEN FRAME Y E WITH BLOCKING 1-LINE PHONE 76" W X 90" H (2130 MM X 2285 MM) MIN. 5/8" W D FIRE RATED PLYWOOD BACKER BOARD CASH SCALE K FOR SECURE ATTACHMENT OF DATA 74" (1880 MM) HEIGHT P POWER & DATA RECEPTACLES L RACK, SHELF, WIFI & ELECTRICAL DEVICES. METRO RACK FOR @ 12" (305 MM) A.F.F. SEE NOTE L FINISH AS SCHEDULED. E 3 . TANK STORAGE ABOVE FOR DESCRIPTION L 3 Z LOCKING SCREW E 0 (PHILLIPS HEAD) A D6 4 L H EQEQ E N MIRROR MOUNTINGMANAGER - DESK ELECTRICAL I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z 7' - 2" & 56 , Scale:Scale: 3/4" = 1'-0" 3/8" = 1'-0" A L T H E S 0 ESCUTCHEON PLATE M 9 1/4" 7 1 R 1 FIXING 7 1/2" 3 A 3 COILED GAS TUBING LOCATION 1 1C (4) 6' - 4" (1930 MM) BOTTOM OF BRACKETWALL BRACKET WITH WIRELESS CEILING STORE #:8123 CHAIN INTERNET HUB PROJECT #:25450-048 LOCATE AND INSTALL ISSUE DATE: 11/1/17 EQEQ 2' - 8" (810 MM) WALL MOUNT BRACKETS DESIGNER: LISA MACEDA PER MANUFACTURER'S R 3' - 0" (915 MM) MIN. CLEAR LEED AP: INSTRUCTIONS IT RACK PRODUCTION DESIGNER: PETER CHEETHAM SHELVING SECURED 1' - 4" (405 MM) CHECKED BY: TO SOLID BLOCKING LAN HUB CARBONATION TANKS NOTE:CYLINDER INSTALL BY SIDE ELECTRICAL AND MODEM AMPLIFIER (STORAGE) Revision Schedule STARBUCKS VENDOR ENTRY POINT 7/8" 11 3/4" 1/2" CEMENTITIOUS MUSIC SYSTEM ALARM RevDateByDescription EQEQ BACKER BOARD ON 3/4" 15 1/2" ELEVATION VIEW FIRE-TREATED PLYWOOD ELECTRONIC PC MONITOR FLR W/ #6 SCREWS @ EQUIPMENT RACK T. O. FRAMING C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 6" O.C. W/FRP. PRINTER 7'-10 3/4" AFF MONEY COUNTER BACK WALL BEAMS @ 8" O.C. MAX DATA REAR CARBONATION LINE TO KEYBOARD AND TRAY ELECTRICAL COLD BEVERAGE STATION. ENTRY POINT SHEET TITLE: COIL AND PLUG 72" (1830 FILE CABINET 5/8" WATER MM) LENGTH OF GAS RESTROOM AND FIXING RESISTANT GYP. BD. TUBING. TIE OFF TUBING LOCATION (4) W/ FRP HELD 6" (150 MM) A.F.F. WORKROOM DETAIL BELOW CHILLER BRACKET 1/4" AS SHOWN SCALE: SHEET NUMBER: HAND DRYER SECTIONMANAGERS DESK (DETAIL FOR INSTALLATION)FILTER SYSTEM SHELF SECTIONCBE CHILLER - PLUMBING 78910 Scale: 3" = 1'-0"Scale: 3/8" = 1'-0"Scale: 1/2" = 1'-0"Scale: 3/4" = 1'-0" I-5003 10/31/2017 6:23:29 PM TILE FIBER REINFORCED PLASTIC 5/8" METAL EDGE FROM CAFE MANUFACTURER OR BEVERAGE PREP. SIMILAR FOR DESIGN FINISH AS SCHEDULED INTENT. SLIDE METAL LEG DIE WALL UNDER MAT. BULLNOSE R BULLNOSE SANITARY BULLNOSE SANITARY 3/8" 6" BULLNOSE COVED TILE BASE SANITARY COVED TILE BASE SANITARY 3/8" BULLNOSE SANITARY C 2017 STARBUCKS COFFEE COMPANY COVED TILE BASE COVED TILE BASE 3/8" COVED TILE BASE ALUMINUM DOWEL STOREFRONT DOOR 6" SECURED INTO SUB TILE FLOORING AND THRESHOLD STARBUCKS COFFEE FLOOR & DIEWALL TILE TILE FLOORING TILE FLOORING NEW OR EXISTING FLOORING COMPANY TILE FLOORING WALK OFF MAT 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 PLASTIC SHIM WATERPROOF DIM. AS PER FLOOR 2" REQUIRED - 1/4" (206) 318-1575 MEMBRANE, (ONLY IF ON FINISH PLAN MIN. WOOD SUBFLOOR) THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, TRANSITION - TILE TO WALK OFF MATTILE BASE AT DIE WALLTILE BASE AT INTERIOR WALLTILE BASE AT PERIMETER WALL WHICH IS THE OWNER OF THE COPYRIGHT IN 1234 THIS WORK. THEY SHALL NOT BE Scale: 3" = 1'-0"Scale: 3" = 1'-0"Scale: 3" = 1'-0"Scale: 3" = 1'-0" REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES WOOD CLADDING BY CASEWORK MANUFACTURER. 6" BULLNOSE CORNER STARBUCKS TEMPLATE VERSION i2017.08.25 MATERIAL THICKNESS VARIES. COVED TILE BASE DOOR JAMB SEE CASEWORK FINISH (BEYOND) SCHEDULE. WALL TILE 1/8" Design Forum 6" BULLNOSE BACKBARWORKROOM SUBSTRATE (MOISTURE FINISH AS INT WALL SANITARY 3/8" COVED RESISTANT) SCHEDULED TILE BASE Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge 6" COVED SANITARY HOT ROLLED STEEL TILE FLOORING6" BULLNOSE Tel: (513) 421-2210License: AR19700147 TILE BASE MT0011 SANITARY 3/8" X1206 - SCHLUTER COVED TILE BASE ALIGN SCHIENE Design Forum 6 1/4" TILE BASE TILE FLOORINGTILE FLOORING TILE FLOORING Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 TILE FLOORING TRANSITION - TILE TO TILETILE BASE AT RESTROOM WALLTILE BASE AT OUTSIDE CORNERCLADDING AT BASE 5678 Scale:Scale:Scale:Scale: 6" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 11/01/1709/01/17 TILE L L Y E METAL EDGE FROM MANUFACTURER W OR SIMILAR FOR DESIGN INTENT. SLIDE D METAL LEG UNDER MAT. CLIP LEG K EDGE AS NEEDED TO FIT A CURVE. P L L WALK OFF MAT E 3 L AS SCHEDULED 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R 1 3 A 3 1 1C TRANSITION - FRAME DETAIL 9 Scale: 3" = 1'-0" STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: FLOOR FINISH DETAILS AS SHOWN SCALE: SHEET NUMBER: I-5004 10/31/2017 6:23:33 PM WALLCOVERING AS SCHEDULED GYPSUM BOARD GROUT WALLCOVERING ADHERED VINYL WALL COVERING DIRECTLY TO THE WALL DRYWALL CORNER REVEAL: R INSTALL PER MFR DRME-625-625 (BY FRY INSTRUCTIONS. 4 REGLET) C 2017 STARBUCKS COFFEE COMPANY FRY REGLET DETAIL I-5005 BASE (BELOW) WALLCOVERING APPLIED STARBUCKS COFFEE DIRECTLY TO WALL PER MFR INSTRUCTIONS COMPANY GROUT LATEX CAULKING 2401 UTAH AVENUE SOUTH 2 SEATTLE, WASHINGTON 98134 2 GYPSUM BOARD NEW TILE BASE; I-5005(206) 318-1575 1" I-5005 SEE DETAIL I-5004 WALLCOVERING THESE DRAWINGS AND SPECIFICATIONS ARE NEW BASE TO OVERLAP AS SCHEDULED CONFIDENTIAL AND SHALL REMAIN THE SOLE VINYL WALLCOVERING PROPERTY OF STARBUCKS CORPORATION, WALL FRAMING WHICH IS THE OWNER OF THE COPYRIGHT IN BASE (PER FLR FINISH THIS WORK. THEY SHALL NOT BE PLAN) REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE VINYL WALL COVERINGVINYL WALL COVERING AT TILE BASEVINYL APPLICATION - OUTSIDE CORNERVERTICAL FRY REGLET "W" REVEAL DETAIL INTENDED TO EXPRESS DESIGN INTENT FOR A 1234 Scale:Scale:Scale:Scale: 3" = 1'-0" 6" = 1'-0" 3/4" = 1'-0" 12" = 1'-0" PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. BACK SPLASHNEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS BACKBAR COUNTERTOP FULLYEXECUTEDBYBOTHPARTIES 2' - 8 3/4" AFF STARBUCKS TEMPLATE VERSION i2017.08.25 GYPSUM WALL EXT WALL 1/4" GAP (TYP) LEFT BOARD B/O COUNTERTOP OPEN FOR GROUT CEMENTITIOUS BOARD STUD WALL AS SCHEDULED, LATEX CAULKING Design Forum EXTENT OF BACKBAR TILE SEE FLR PLAN 5/16" WALL TILE 1/4" FRP APPLIED DIRECTLY TO GYP. BD. 5/8" GROUT Architects Inc. WALL PER MFR SPEC 700 W. Pete Rose Way, Suite 460Donald J. Rethman 5/16" WALL TILE Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 1/4" GROUT SOLID ALIGN SURFACE Design Forum REMOVABLE CABINET BACK BACKSPLASH GREEN BOARD ATTACHED PANEL 3/8" (12MM) "L" 7" TO EXISTING GYP BOARD SHAPED METAL OPEN AREA Engineering AT BACK BAR W/ TRIM BEHIND SOLID 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE DRYWALL SCREWS @ 16" 1" Overlap SURFACE 6IN ADJUSTABLE STAINLESS Cincinnati, OH 45203Professional Engineer STAINLESS STEEL O.C. License: PE10504904 Tel: (513) 421-2210 STEEL LEGS BACKSPLASH (WHERE OCCURS) TILE BASE FRP AT BACKLINE CABINETWALL TILE ABOVE SST BACKSPLASHWALL TILE ABOVE SS BACKSPLASHTILE GREEN BOARD DTL 5678 Scale:Scale:Scale:Scale: 1 1/2" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" TILE FINISH AS TYP. TILE GROUT THICKNESS SUBSTRATE 11/01/1709/01/17 SCHEDULED1/16" CUSTOM BUILDING WALL FRAMING PRODUCTS CHARCOAL **NO WOOD CLADDING SUBSTITUTIONS** FINISH: WD0073 WOOD SOFFIT WALLCOVERING FINISH X1207 - SCHLUTER AS SCHEDULED TILE X1015 - SCHLUTER JOLLY INSTALLED INDEC L HORIZONTALLY PER MANUFACTURER GYPSUM BOARD L STACKED RECOMMENDATIONS TILE FINISH AS FULL TILE Y X1207 - SCHLUTER E SCHEDULED WALL FRAMING SCHIENE W D K CEMENT BOARD FULL TILE BACKBAR TILE AS P L TYP. TILE GROUT THICKNESS SCHEDULED 1/16" CUSTOM BUILDING L E 3 CEMENT BOARD PRODUCTS CHARCOAL **NO L 3 Z SUBSTITUTIONS** E 0 1/2 OFFSET (BRICK) A D6 4 L CEMENT BOARD H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , WALL FRAMING A L T H E S 0 BACKBAR WALL TILE PATTERNTILE CORNER - TRIMTRANSITION - WOOD TO TILETRANSITION - WALLCOVERING TO TILE M 7 9101112 1 R Scale: 1 1/2" = 1'-0"Scale: 6" = 1'-0"Scale: 3" = 1'-0"Scale: 3" = 1'-0" 1 3 A 3 1 1C STORE #:8123 SUBSTRATE PROJECT #:25450-048 WOOD CLADDING ISSUE DATE: 11/1/17 FINISH: WD0073 DESIGNER: LISA MACEDA WOOD CLADDING R LEED AP: FINISH: WD0073 X1207 - SCHLUTER GYP. BOARD PRODUCTION DESIGNER: PETER CHEETHAM SCHIENE CHECKED BY: PLYWOOD BACKING BLOCKING AS GYPSUM BOARD WALLCOVERING FINISH WOOD CLADDING REQUIRED WALL FRAMING WALL FRAMING Revision Schedule AS SCHEDULED WALL FRAMING FINISH: WD0073 GYP. BOARD RevDateByDescription FRP FINISH AS WALLCOVERING FINISH WALL FRAMINGPLYWOOD BACKING GYP BOARD AS SCHEDULED SCHEDULED FINISH AS CAFEENGINE AREA C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SCHEDULED PLYWOOD BACKING MITER JOINT 1/2" SOLID WOOD CAULK PAINTED TO MATCH ADJACENT FINISH. COUNTER SUNK 1/2" SOLID WOOD MITER JOINT SHEET TITLE: SCREWS PAINTED TO MATCH 15 ADJACENT FINISH WALL FINISH DETAILS I-5005 FINISHED EDGE AS SHOWN SCALE: TRANSITION - WALLCOVERING TO WOODFINISHED EDGE DETAIL-WORKROOMCAULK DETAILMITER CORNER DETAIL 13141516 Scale: 3" = 1'-0"Scale: 3" = 1'-0"Scale: 12" = 1'-0"Scale: 3" = 1'-0" SHEET NUMBER: I-5005 10/31/2017 6:23:38 PM INDIRECT AND INSULATED INDIRECT DRAIN LINE DRAIN LINE FROM ICE BIN FROM DRIP TRAY TO TO FLOOR SINK FLOOR SINK AS REQ'D. 7"X3" (180MMX75MM) STUB-UP INDIRECT DRAIN LINES PENETRATION AREA. SEE FROM ESPRESSO PLUMBING PLAN FOR FINAL MACHINES TO FLOOR SINKS INDIRECT DRAIN LINE INDIRECT DRAIN LINE LOCATION. INSTALL SHUT-OFF FROM IN-USE UTENSIL FROM UNDERCOUNTER VALVES BETWEEN STUB-UPS AND RINSE SINK TO FLOOR SINKREFRIGERATOR TO EQUIPMENT. FLOOR SINK. CUP LABELER (BELOW) INDIRECT DRAIN LINE R VERIFY IN SCOPE FROM IN-USE UTENSIL RINSE SINK TO FLOOR C 2017 STARBUCKS COFFEE COMPANY UNDERCOUNTER SINK UNDERCOUNTER REFRIGERATOR REFRIGERATOR STARBUCKS COFFEE FILTERED COLD WATER INDIRECT AND SUPPLY FOR ESPRESSO INDIRECT DRAIN LINE COMPANY INSULATED DRAIN LINE MACHINE (TYP.) FROM ESPRESSO FROM ICE BIN TO 2401 UTAH AVENUE SOUTH MACHINE TO FLOOR SINK FLOOR SINK FILTERED COLD WATER SEATTLE, WASHINGTON 98134 SUPPLY FOR WATER (206) 318-1575 TOWER FAUCET (TYP) SEE PLUMBING PLAN FOR FINAL FLOOR SINK THESE DRAWINGS AND SPECIFICATIONS ARE FILTERED COLD WATER INDIRECT DRAIN LINE FROM LOCATION AND TYPE. CONFIDENTIAL AND SHALL REMAIN THE SOLE SUPPLY FOR INSTANT IN-USE UTENSIL RINSE SINK COORDINATE LOCATION PROPERTY OF STARBUCKS CORPORATION, HOT WATER TAP (TYP) TO FLOOR SINK WITH SUPPORT LEGS (TYP)WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE HOT AND COLD WATER REPRODUCED (IN WHOLE OR IN PART), SHARED SUPPLY FOR PITCHER SEE PLUMBING PLAN WITH THIRD PARTIES OR USED IN ANY MANNER UNDERCOUNTSEE PLUMBING PLAN RINSER FAUCET (TYP) FOR FINAL FLOOR SINK ON OTHER PROJECTS OR EXTENSIONS TO THIS ER CABINETFOR FINAL FLOOR LOCATION AND TYPE. PROJECT WITHOUT THE PRIOR WRITTEN SINK LOCATION AND PLUMBING COMPONENTS CONSENT OF STARBUCKS CORPORATION. TYPE. COORDINATE COLD WATER SUPPLY FOR UNDERCOUNTER THESE DRAWINGS AND SPECIFICATIONS ARE LOCATION WITH METERED SPOON RINSER REFRIGERATOR INDIRECT AND INSULATED INTENDED TO EXPRESS DESIGN INTENT FOR A SUPPORT LEGS (TYP) FAUCET (TYP) DRAIN LINE FROM ICE BIN 1' - 6" PROTOTYPICAL STARBUCKS STORE (WHICH IS TO FLOOR SINK SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NITRO MACHINE NEITHER PARTY SHALL HAVE ANY OBLIGATION UNDER COUNTER NOR LIABILITY TO THE OTHER (EXCEPT STATED PLAN VIEW ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 DT ESPRESSO - PLUMBING FOR REFERENCE ONLY 2 Scale: 3/4" = 1'-0" FILTERED COLD WATER SUPPLY FOR WATER FILTERED COLD WATER Design Forum TOWER FAUCET (TYP) SUPPLY FOR WATER DIEWALL (BELOW) TOWER FAUCET Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 FILTERED COLD WATER SEE PLUMBING PLAN FOR FINAL SUPPLY FOR INSTANT FLOOR SINK LOCATION AND HOT WATER TAP Design Forum TYPE. HOT AND COLD WATER Engineering COLD WATER SUPPLY FOR SUPPLY FOR PITCHER 4' - 0"10" PITCHER RINSER RINSER FAUCET 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 SEE PLUMBING PLAN FOR FINAL 10" COLD WATER SUPPLY DIRECT DRAIN LINE FROM SINK FLOOR SINK LOCATION AND FOR METERED SPOON TO FLOOR SINK TYPE. RINSER FAUCET HOT AND COLD WATER FOR COLD WATER SUPPLY FOR COUNTER TOPSINK FAUCET AT 20 1/2" (520 MM) IN-COUNTER RINSER AT 20 1/2" A.F.F. SHUT-OFF VALVES AT (520 MM) A.F.F. WALL AND 4" (100 MM) EITHER SIDE OF WASTE LINE ABOVE COUNTER INDIRECT LINE FROM IN- COUNTER RINSER TO FLOOR SINK DIRECT LINE FROM DRAINBOARD TO 11/01/17 09/01/17 INDIRECT LINE FROM DRIP TRAY TO FLOOR SINK FLOOR SINK NITRO MACHINE INSULATED WATER LINE FROM DIRECT DRAIN LINE FROM ICE WATER CHILLER IN B.O.H. INSTALL L BIN TO FLOOR SINK PER MANUFACTURER'S INSTRUCTIONS. L Y E W D K P L L E 3 L 3 Z ESPRESSO - PLUMBING FOR REFERENCE ONLYCB E - PLUMBING FOR REFERENCE ONLY E 0 13 A D6 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R 1 3 A 3 1 1C FILTERED COLD WATER SUPPLY FOR BREWER WITH STORE #:8123 SHUT-OFF IN CABINET AT PROJECT #:25450-048 24" (610 MM) A.F.F. ISSUE DATE: 11/1/17 DIRECT DRAIN LINE DESIGNER: LISA MACEDA FROM SINK. ROUGH-IN R LEED AP: SINK WASTE STUB AT 15 PRODUCTION DESIGNER: PETER CHEETHAM 1/2" (395 MM) A.F.F. AND CHECKED BY: TEMPERED HOT AND COLD CENTERLINE OF SINK. WATER FOR SINK FAUCET AT 20 1/2" (520MM) AFF. Revision Schedule HOT AND COLD WATER FOR SHUT-OFF VALVES AT WALL SINK FAUCET AT 20 1/2" (520 AND 4" (102MM) EITHER SIDE RevDateByDescription 2' - 6 1/2" MM) A.F.F. SHUT-OFF VALVES OF WASTE LINE AT WALL AND 4" (100 MM) EITHER SIDE OF WASTE LINE. INDIRECT DRAIN LINE FROM C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SINK. ROUGH-IN SINK WASTE STUB AT 15 1/2" (394MM) AFF AND CENTERLINE OF SINK 7 1/4" EQEQ SHEET TITLE: CASEWORK DETAILS 1' - 3" 3/4" = 1'-0" SCALE: SHEET NUMBER: CB BREW - PLUMBING FOR REFERENCE ONLYHANDSINK - PLUMBING FOR REFERENCE ONLY 45 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" I-5006 10/31/2017 6:23:46 PM 12' - 3" 1' - 10 1/2"2' - 1 1/2"2' - 1 1/2"1' - 6"2' - 9" R C 2017 STARBUCKS COFFEE COMPANY STARBUCKS COFFEE RECEPTACLE FOR INSTANT HOT WATER TAP AT 26" (660 MM) A.F.F. COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 POWER AND DATA RECEPTACLES (MOUNTED AT DIEWALL) (206) 318-1575 RECEPTACLE FOR UNDERCOUNTER 5' - 7 3/4" -REFRIGERATOR AT 26" (660 MM) A.F.F. THESE DRAWINGS AND SPECIFICATIONS ARE RECEPTACLE FOR ESPRESSO CONFIDENTIAL AND SHALL REMAIN THE SOLE MACHINE AT 26" (660) A.F.F. PROPERTY OF STARBUCKS CORPORATION, DATA PORT FOR FUTURE USE AT WHICH IS THE OWNER OF THE COPYRIGHT IN RECEPTACLE FOR 26" (660 MM) A.F.F. THIS WORK. THEY SHALL NOT BE INSTANT HOT WATER TAP REPRODUCED (IN WHOLE OR IN PART), SHARED AT 26" (660 MM) A.F.F. WITH THIRD PARTIES OR USED IN ANY MANNER POWER AND DATA RECEPTACLES ON OTHER PROJECTS OR EXTENSIONS TO THIS (MOUNTED AT DIEWALL) RECEPTACLE FOR NITRO PROJECT WITHOUT THE PRIOR WRITTEN (2) RECEPTACLES FOR CUP MACHINE AT 26" (660MM) AFF CONSENT OF STARBUCKS CORPORATION. LABELERS AT 26" (660 MM) A.F.F. THESE DRAWINGS AND SPECIFICATIONS ARE (2) DATA PORTS FOR CUP LABELERS INTENDED TO EXPRESS DESIGN INTENT FOR A AT 26" (660 MM) A.F.F. PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 21" X 3" (460 MM X 75 MM) STUB-UP POWER AND DATA RECEPTACLES NOT REFLECT ACTUAL SITE CONDITIONS. UNDERCOUNTER PENETRATION AREA. SUPPLY POWER, (MOUNTED TO DIEWALL) NEITHER PARTY SHALL HAVE ANY OBLIGATION REFRIGERATORS (TYP.) RECEPTACLE FOR UNDERCOUNTER DATA, AND PHONE CONDUITS FOR NOR LIABILITY TO THE OTHER (EXCEPT STATED POS AND POWER CONDUIT FOR REFRIGERATOR AT 26" (660 MM) A.F.F. CUP LABELER ABOVE) UNTIL A WRITTEN AGREEMENT IS PASTRY CASE. SEE ELECTRICAL RECEPTACLE FOR ESPRESSO (BELOW) FULLYEXECUTEDBYBOTHPARTIES DESIGN PLAN FOR FINAL LOCATIONMACHINE AT 26" (660 MM) A.F.F. ELECTRICAL COMPONENT DATA PORT FOR FUTURE USE AT STARBUCKS TEMPLATE VERSION i2017.08.25 26" (660 MM) A.F.F. POWER AND DATA RECEPTACLES WIRE GROMMET TYP. (AT FACE OF WALL) COUNTER TOP RECEPTACLE FOR CUP LABELER AT Design Forum 26" (660 MM) A.F.F. DATA PORT FOR CUP LABELER CUP LABELER (BELOW) AT 26" (660 MM) A.F.F. Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 ESPRESSO MACHINE MASTRENA Design Forum UNDERCOUNTER WIRE GROMMET TYP. REFRIGERATOR Engineering UNDERCOUNTER 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE 9" REFRIGERATORS POWER AND DATA RECEPTACLES Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 6' - 8"6' - 8" (AT FACE OF WALL) RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR AT 26" (660 MM) A.F.F. 1' - 2" DIEWALL (BELOW) RECEPTACLE FOR ESPRESSO MACHINE AT 26" (660) A.F.F. DATA PORT FOR FUTURE USE AT 26" (660 MM) A.F.F. PLAN VIEWCOUNTER TOPUNDERCOUNTER REFRIGERATORS RECEPTACLE FOR INSTANT HOT WATER TAP ESPRESSO MACHINE 1' - 11" AT 26" (660 MM) A.F.F. (AT PLAN VIEW MASTRENA 11/01/17 09/01/17 FACE OF WALL) ELECTRICAL COMPONENT NITRO SYSTEM L L Y E ESPRESSO - ELECTRICAL FOR REFERENCE ONLYDT ESPRESSO - ELECTRICAL FOR REFERENCE ONLY W D 12 K Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" P L L E 3 NOTE: L 3 Z FOR INFORMATION AND COORDINATION E 0 ONLY; ENGINEER TO MODIFY AS A D6 POWER AND DATA RECEPTACLES APPROPRIATE 4 (2) RECEPTACLES FOR CUP LABELERS L H (2) DATA PORTS FOR CUP LABELERS E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt ESPRESSO MACHINE (TYP)Z & , A PLUMBING FIXTURES FOR IN-USE UTENSIL SINK L CUP LABELER (TYP) COLD FILTERED WATER T H E HOT FILTERED WATER S 0 M FAUCET WITH BLENDER 7 1 PITCHER RINSER R FUTURE ESPRESSO MACHINE 1 HAND METERED FAUCET 3 A 3 1 1C POWER AND DATA RECEPTACLES POWER RECEPTACLE RECEPTACLE FOR UNDERCOUNTER ICE BIN INSTANT HOT WATER TAP REFRIGERATOR PLUMBING FIXTURES FOR IN- STORE #:8123 RECEPTACLE FOR ESPRESSO MACHINE USE UTENSIL SINK POWER RECEPTACLE PROJECT #:25450-048 DATA PORT FOR FUTURE USE COLD FILTERED WATER INSTANT HOT WATER TAP HOT FILTERED WATER ISSUE DATE: 11/1/17 POWER AND DATA RECEPTACLES FAUCET WITH BLENDER DESIGNER: LISA MACEDA RECEPTACLE FOR CUP LABELER PITCHER RINSER R LEED AP: UNDERCOUNTER REFRIGERATOR HAND METERED FAUCET PLUMBING STUB-UPS. SEE PRODUCTION DESIGNER: PETER CHEETHAM RECEPTACLE FOR ESPRESSO PLUMBING DESIGN PLAN POWER AND DATA RECEPTACLES CHECKED BY: MACHINE FOR FINAL LOCATION (2) RECEPTACLES FOR CUP DATA PORT FOR FUTURE USE ICE BIN LABELERS Revision Schedule (2) DATA PORTS FOR CUP LABELERS POWER RECEPTACLE ESPRESSO PUMPS INSTANT HOT WATER TAP RevDateByDescription MOUNTED BEHIND CABINET ON BACKER BOARD PER SST SUPPORT LEG MANUFACTURER SPECS POWER AND DATA RECEPTACLES ESPRESSO PUMP MOUNTED C:\\Users\\zach.scholl\\Documents\\Starbucks_131st RECEPTACLE FOR UNDERCOUNTER ON BACKER BOARD PER POWER AND DATA STUB-UPS REFRIGERATOR MANUFACTURER SPECS PLUMBING STUB-UPS. SEE ELECTRICAL DESIGN RECEPTACLE FOR ESPRESSO MACHINE SEE PLUMBING DESIGN PLAN FOR FINAL LOCATION DATA PORT FOR FUTURE USE PLAN FOR FINAL LOCATION SHEET TITLE: UNDERCOUNTER CASEWORK DETAILS REFRIGERATOR PARTNER SIDE 3/4" = 1'-0" SCALE: PARTNER SIDE SHEET NUMBER: DOUBLE ESP MEP DIAGRAMDT ESP MEP DIAGRAM 34 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" I-5007 10/31/2017 6:23:55 PM 6' - 10" 3' - 5" EDGE OF CABINET SHELVING (BELOW) 2' - 11 1/4" R POWER AND DATA RECEPTACLES QUAD RECEPTACLE FOR C 2017 STARBUCKS COFFEE COMPANY 18" X 23" (460 MM X 75 MM) STUB-UP EDGE OF COUNTERTOP UNDERCOUNTER REFRIGERATOR AND PENETRATION AREA. SUPPLY POWER, FUTURE USE AT 26" (660 MM) A.F.F. 2' - 11" DATA AND PHONE CONDUITS FOR POS DATA PORT FOR FUTURE USE STARBUCKS COFFEE AND POWER CONDUIT FOR PASTRY AT 26" (660 MM) A.F.F. POWER AND DATA RECEPTACLES CASE. SEE ELECTRICAL DESIGN PLAN COMPANY - DEDICATED POS RECEPTACLE AT 18" (460 MM) A.F.F. FOR FINAL LOCATION. - DATA PORT FOR SAFE SECURITY AT 18" (460 MM) 2401 UTAH AVENUE SOUTH A.F.F. SEATTLE, WASHINGTON 98134 - QUAD RECEPTACLE FOR SAFE SECURITY AND ELECTRICAL COMPONENT DT LANDING - LABELER AT 18" (206) 318-1575 COUNTER TOP (460 MM) A.F.F. THESE DRAWINGS AND SPECIFICATIONS ARE - JUNCTION BOX FOR PHONE AT CONFIDENTIAL AND SHALL REMAIN THE SOLE 18" (460 MM) A.F.F. PROPERTY OF STARBUCKS CORPORATION, - DATA PORT FOR POS AND CUP LABELER FOR WHICH IS THE OWNER OF THE COPYRIGHT IN MOBILE ORDER AND PAY AT 18" (460 MM) A.F.F. THIS WORK. THEY SHALL NOT BE - QUAD RECEPTACLE AT 18" (460 MM) A.F.F. REPRODUCED (IN WHOLE OR IN PART), SHARED POWER AND DATA RECEPTACLES WITH THIRD PARTIES OR USED IN ANY MANNER DEDICATED QUAD RECEPTACLE FOR ON OTHER PROJECTS OR EXTENSIONS TO THIS DRIVE-THRU EXPEDITOR MONITOR AT 5'-5" PROJECT WITHOUT THE PRIOR WRITTEN 1' - 2 1/2" (1650 MM) A.F.F. CONSENT OF STARBUCKS CORPORATION. 6' - 11 1/2" DATA PORT AT 5'-5" (1650 MM) A.F.F. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A FINISH PANEL POWER AND DATA RECEPTACLES PROTOTYPICAL STARBUCKS STORE (WHICH IS (2) DEDICATED QUAD RECEPTACLE FOR SUBJECT TO CHANGE AT ANYTIME) AND DO DIEWALL DRIVE-THRU TIMER MONITOR AT 6'-9" (2060 NOT REFLECT ACTUAL SITE CONDITIONS. MM) A.F.F NEITHER PARTY SHALL HAVE ANY OBLIGATION 1' - 10" 6' - 11" FACE OF WALL (2) DATA PORT AT 6'-9" (2060 MM) A.F.F. NOR LIABILITY TO THE OTHER (EXCEPT STATED WIRE GROMMET TYP. ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES POWER AND DATA RECEPTACLES - (2) DEDICATED RECEPTACLE FOR STARBUCKS TEMPLATE VERSION i2017.08.25 CABINET (UNDER) WIRELESS BASE AND SIGNAL WIRE GROMMET TYP. PROCESSOR AT 8'-0" 1' - 3" (2440 MM) A.F.F. Design Forum POS COUNTER TOP (2) DATA PORT AT 8'-0" (2440 MM) A.F.F DT POS - COUNTER TOP Architects Inc. POWER AND DATA RECEPTACLES 700 W. Pete Rose Way, Suite 460Donald J. Rethman LEGS Cincinnati, OH 45203Architect In Charge - DEDICATED QUAD RECEPTACLE FOR (BELOW) Tel: (513) 421-2210License: AR19700147 DRIVE-THRU REGISTER AND EXPEDITOR TILL ELECTRICAL COMPONENT AT 22" (560 MM) A.F.F - DEDICATED QUAD RECEPTACLE FOR PLAN VIEW Design Forum FUTURE USE AT 22" (560 MM) A.F.F. (2) DATA PORT AT 22" (560 MM) A.F.F. Engineering PLAN VIEW 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 POS - ELECTRICAL FOR REFERENCE ONLY Tel: (513) 421-2210 DT POS - ELECTRICAL FOR REFERENCE ONLY 2 1 Scale: 3/4" = 1'-0" Scale: 3/4" = 1'-0" POWER & DATA RECEPTACLES - (2) DEDICATED DUPLEX RECEPTACLE FOR WIRELESS BASE & SIGNAL PROCESSOR - (2) DATA JUNCTION BOX - SAME DEDICATED CIRCUIT AS BELOW 11/01/17 09/01/17 DRIVE-THRU WIRELESS HEADSET BASE STATION L DRIVE-THRU TIMER L MONITOR Y E W DRIVE-THRU TIMER POWER & DATA RECEPTACLES D K CONTROL UNIT - (2) DEDICATED DOUBLE DUPLEX RECEPTACLE FOR P DRIVE-THRU TIMER MONITOR AND CONTROL UNIT L - (2) DATA JUNCTION BOX NOTE: L E 3 FOR INFORMATION AND COORDINATION ONLY; L 3 CUP LABELER PROVIDE Z ENGINEER TO MODIFY AS APPROPRIATE DRIVE-THRU TIMER POWER & DATA RECEPTACLES E 0 POWER AND DATA AS SIGNAL PROCESSOR (TSP) - DEDICATED DOUBLE DUPLEX RECEPTACLE FOR A D6 REQUIRED COORDINATE DRIVE-THRU EXPEDITOR MONITOR 4 WITH STARBUCKS CM AND L - DATA JUNCTION BOX H ELECTRICAL DRAWINGS DRIVE-THRU ORDER E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt MONITOR Z & , POS MONITOR (TYP)CASH DRAWERS A L POWER AND DATA RECEPTACLES (BEHIND) T H DRIVE-THRU BUMP BAR -DEDICATED QUAD RECEPTACLE FOR DRIVE E THRU REGISTER AND EXPEDITOR TILL S 0 M -DEDICATED QUAD RECEPTACLE FOR FUTURE 7 1 DRIVE-THRU EXPEDITER R POS BANKS (TYP) USE 1 3 A -(2) DATA JUNCTION BOX 3 DRIVE-THRU 1 1C 8' - 0" POWER RECEPTACLES TENDERING REGISTER -QUAD RECEPTACLE FOR UNDERCOUNTER STORE #:8123 REFRIGERATOR AND FUTURE USE 6' - 9" -DATA JUNCTION BOX PROJECT #:25450-048 PHONE ISSUE DATE: 11/1/17 POWER, PHONE AND DATA NETWORK SWITCH DESIGNER: LISA MACEDA 5' - 5" RECEPTACLES R (PROVIDED BY LEED AP: (RELOCATE AS NECESSARY) STARBUCKS VENDOR) PRODUCTION DESIGNER: PETER CHEETHAM -DEDICATED POS RECEPTACLE CHECKED BY: -DATA PORT FOR SAFE SECURITY -QUAD RECEPTACLE FOR SAFE SECURITY Revision Schedule AND LABELER POWER AND DATA STUB- -JUNCTION BOX FOR PHONE RevDateByDescription UPS (BEHIND TOE KICK) SEE 2' - 2" -DATA PORT FOR POS AND CUP ELECTRICAL DESIGN PLAN 1' - 10" LABELER FOR FINAL LOCATION FOR MOBILE ORDER AND PAY C:\\Users\\zach.scholl\\Documents\\Starbucks_131st -QUAD RECEPTACLE PARTNER SIDE PARTNER SIDE VIEW SHEET TITLE: CASEWORK DETAILS 3/4" = 1'-0" SCALE: SHEET NUMBER: DRIVE-THRU POS DIAGRAM - FOR REFERENCE ONLYGENERIC DOUBLE POS MEP DIAGRAM 34 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" I-5008 10/31/2017 6:24:01 PM INTEGRAL BACKSPLASH R RECEPTACLE FOR BREWER & DATA PORT FOR FUTURE USE POWER AND DATA RECEPTACLES POWER AND DATA RECEPTACLES C 2017 STARBUCKS COFFEE COMPANY AT 26" (660 MM) A.F.F.WIRE GROMMET TYP.. (2) RECEPTACLES FOR RECEPTACLE FOR OPTIONAL BLENDER(S) AT 26" (660 MM) A.F.F. CARBONATION MACHINE AT 26" (660 RECEPTACLE FOR STARBUCKS COFFEE MM) A.F.F. UNDERCOUNTER REFRIGERATOR RECEPTACLE FOR UNDERCOUNTER AT 26" (660 MM) A.F.F. COMPANY QUAD RECEPTACLE FOR REFRIGERATOR AT 26" (660 MM) DATA PORT FOR FUTURE USE AT COFFEE WARMER & A.F.F. 26" (660 MM) A.F.F. 2401 UTAH AVENUE SOUTH DATA PORT FOR FUTURE DATA PORT FOR FUTURE USE AT 26" SEATTLE, WASHINGTON 98134 USE AT 26" (660 MM) (660 MM) A.F.F. A.F.F. (206) 318-1575 RECEPTACLE FOR RINSE SINK THESE DRAWINGS AND SPECIFICATIONS ARE RECEPTACLE FOR AT 26" (660 MM) A.F.F. CONFIDENTIAL AND SHALL REMAIN THE SOLE GRINDER AND SCALE 26" WIRE GROMMET PROPERTY OF STARBUCKS CORPORATION, (660 MM) A.F.F. TYP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED 7 1/2"1' - 3"4' - 3" 1' - 3"2' - 7 1/2"1' - 2"9" WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS 9' - 2 1/4" 8' - 9" PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO CBE - ELECTRICAL FOR REFERENCE ONLY NOT REFLECT ACTUAL SITE CONDITIONS. CB BREW - ELECTRICAL FOR REFERENCE ONLY 2 NEITHER PARTY SHALL HAVE ANY OBLIGATION Scale: 3/4" = 1'-0" 1 NOR LIABILITY TO THE OTHER (EXCEPT STATED Scale: 3/4" = 1'-0" ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 Design Forum WIRE GROMMET UNDERCOUNTER Architects Inc. POWER RECEPTACLE & DATA REFRIGERATORS 700 W. Pete Rose Way, Suite 460Donald J. Rethman PORT FOR PRINTER AT Cincinnati, OH 45203Architect In Charge 26" (660 MM) A.F.F. Tel: (513) 421-2210License: AR19700147 CUP LABELER Design Forum 7 1/2" WIRE GROMMET, Engineering TYP. 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer FACE OF WALL License: PE10504904 RECEPTACLE Tel: (513) 421-2210 2' - 7" FOR WARMING OVEN AT 26" (660 MM) A.F.F. RECEPTACLE FOR WARMING RECEPTACLE & OVEN AT 26" DATA PORT FOR (660 MM) A.F.F. 10"10"1' - 8"10" CUP LABELER AT 26" (660 MM) A.F.F. 5' - 0" 11/01/1709/01/17 WARMING - ELECTRICAL FOR REFERENCE ONLYMOP - ELECTRICAL FOR REFERENCE ONLY 34 Scale:Scale: 3/4" = 1'-0" 3/4" = 1'-0" L L Y E W D K P L L E 3 L 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 DESIGNER: LISA MACEDA R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM CHECKED BY: Revision Schedule RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st SHEET TITLE: CASEWORK DETAILS 3/4" = 1'-0" SCALE: SHEET NUMBER: I-5009 10/31/2017 6:24:06 PM NOTE: SHOP DRAWINGS TO BE APPROVED BY SB DESIGNER PRIOR TO FABRICATION. 1' - 3 1/4" R 23' - 5" (FRONT BAR DIEWALL AND FINISH PANEL) C 2017 STARBUCKS COFFEE COMPANY 6' - 10" (POS DIEWALL AND FINISH PANEL)12' - 3" (ESPRESSO DIEWALL AND FINISH PANEL)2' - 7 1/4"1' - 8 3/4" STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 6 2' - 11 1/4" (206) 318-1575 I-5011 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE 1' - 7 3/4" PROPERTY OF STARBUCKS CORPORATION, NOTE: WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE MODIFIED DT POS COUNTERTOP REPRODUCED (IN WHOLE OR IN PART), SHARED BASED ON STARBUCKS STANDARD. WITH THIRD PARTIES OR USED IN ANY MANNER DETAIL MODIFIED FOR SHOWN ON OTHER PROJECTS OR EXTENSIONS TO THIS DIMENSIONS ONLY. PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. BY CASEWORK VENDOR; SEE FINISH THESE DRAWINGS AND SPECIFICATIONS ARE SCHEDULE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS 18135 - ESPRESSO SOLID 17830 - POS SOLID SURFACE SUBJECT TO CHANGE AT ANYTIME) AND DO 3 SURFACE COUNTER TOP (ABOVE) NOT REFLECT ACTUAL SITE CONDITIONS. COUNTER TOP (ABOVE) 9' - 11" INTEGRAL FINISH: CP0002 I-5011 NEITHER PARTY SHALL HAVE ANY OBLIGATION FINISH: CP0002 BACKSPLASH NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS X1003 - NITRO AND HOP SOLID 18137 - ESPRESSO DIEWALL 17831 - POS DIEWALL FULLYEXECUTEDBYBOTHPARTIES SURFACE COUNTER TOP (ABOVE) FACE OF WALL FINISH: CP0002 X1001 - FRONT BAR FINISH PANEL STARBUCKS TEMPLATE VERSION i2017.08.25 (FINISH: WD0073) WOOD SLATS STEEL CAP AT END 6' - 4 1/2" X1006 - CBE BREW SOLID SURFACE COUNTER TOP 6' - 11 1/2" X1002 - NITRO AND HOP DIEWALL FINISH: CP0002 Design Forum X1001 - NITRO AND HOP FINISH PANEL NOTE: (FINISH: WD0073) WOOD SLATS Architects Inc. 8' - 0 1/4" (NITRO AND HOP DIEWALL AND FINISH PANEL) MODIFIED FRONT BAR DIEWALL AND FINISH PANEL BASED ON WIRE GROMMET TYP. 700 W. Pete Rose Way, Suite 460Donald J. Rethman STARBUCKS STANDARD. Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 DETAIL MODIFIED FOR SHOWN DIMENSIONS ONLY. BY CASEWORK VENDOR; SEE FINISH SCHEDULE Design Forum Engineering 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 NO CHANGE FRONT BAR DIEWALL AND FINISH PANELX1006 - DT POS COUNTER TOP 12 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" 11/01/1709/01/17 23' - 9 3/4" (FRONTBAR COUNTER TOP) L 6' - 10" (17830 - POS COUNTER TOP FINISH: CP0002)12' - 3" (18135 - ESPRESSO COUNTER TOP FINISH: CP0002)2' - 11"1' - 9 3/4" L Y E 12' - 5 3/4" (18139 - ESPRESSO SHROUD FINISH: CP0002) W D K P L L E 3 L 3 Z E 0 2 1/4" 1' - 0" A D6 1' - 10" 4 L H CUT- CUT- E N CUT-CUT- OUT OUT I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z 3' - 4" & OUT OUT , FOR FOR A 1' - 7"1' - 7" FORFOR L RINSE RINSE T 1' - 4 3/4"1' - 4 3/4" ICE BINICE BIN H SINKSINK E S 0 M 7 1 R NOTE: 1 8"8"8"8" 3 A 3 MODIFIED MOP COUNTERTOP BASED ON STARBUCKS 1 1C STANDARD. ESPRESSO TOP 1' - 1"11 1/2" DETAIL MODIFIED FOR SHOWN DIMENSIONS ONLY. 11 1/2"1' - 1" CAP FINISH: CP0002 STORE #:8123 17831 - POS DIEWALL 32 1/4" 18137 - ESPRESSO BY CASEWORK VENDOR; SEE FINISH SCHEDULE 2" PROJECT #:25450-048 6 (BELOW) 8 2 1/4" DIEWALL (BELOW) I-5011 2" ISSUE DATE: 11/1/17 I-5011 I-5011 8 DESIGNER: X1001- POS SOLID SURFACE X1001 - FRONT BAR LISA MACEDA R LEED AP: COUNTER TOPFINISH PANEL (BELOW) I-5011 PRODUCTION DESIGNER: FINISH: CP0002FINISH: WD0073 WOOD PETER CHEETHAM WIRE GROMMET TYP. CHECKED BY: SLATS 6' - 8" X1001- ESPRESSO SOLID X1002 - NITRO AND HOP 8 SURFACE COUNTER TOPDIEWALL (BELOW) Revision Schedule I-5011 FINISH: CP0002 RevDateByDescription X1001 - NITRO AND HOP NOTE: FACE OF WALL FINISH PANEL (BELOW) FINISH: WD0073 WOOD SLATS 1' - 10 3/4" MODIFIED FRONT BAR COUNTERTOP BASED ON 2' - 7" X1005 - CBE BREW SOLID C:\\Users\\zach.scholl\\Documents\\Starbucks_131st STARBUCKS STANDARD. 8' - 5 3/4" (X1003 - NITRO AND HOP COUNTER TOP FINISH: CP0002) SURFACE COUNTER TOP DETAIL MODIFIED FOR SHOWN DIMENSIONS ONLY. X1003- NITRO AND HOP SOLID FINISH: CP0002 SURFACE COUNTER TOP 5" BY CASEWORK VENDOR; SEE FINISH SCHEDULE FINISH: CP0002 3 1/2" INTEGRAL SHEET TITLE: BACKSPLASH CASEWORK DETAILS (NO CHANGE) 3/4" = 1'-0" SCALE: 3' - 4" FRONT BAR COUNTER TOPX1005 - MOP COUNTER TOP SHEET NUMBER: 34 Scale:Scale: 3/4" = 1'-0" 3/4" = 1'-0" I-5010 10/31/2017 6:24:10 PM NOTE: SHOP DRAWINGS TO BE APPROVED BY ESPRESSO MACHINE SB DESIGNER PRIOR TO FABRICATION. (TYP.) POS MONITOR ESPRESSO SHROUD FRONT BAR R COUNTER TOP FINISH: CP0002 PAINT FINISH C 2017 STARBUCKS COFFEE COMPANY AS SCHEDULED 2' - 10" AFF STARBUCKS COFFEE WOOD SLATS BACKBAR COUNTERTOP FINISH: WD0073 COMPANY 1/2" 1 1/4" 2401 UTAH AVENUE SOUTH 1/2" 2" SEATTLE, WASHINGTON 98134 FINISH PANEL (206) 318-1575 FINISH: WD0073 (TYP.) 3/4"PLYWOOD (TYP.) 2 BACKING 2' - 10" THESE DRAWINGS AND SPECIFICATIONS ARE I-5011 2' - 8 1/4" CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE TILE BASE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER 2" ON OTHER PROJECTS OR EXTENSIONS TO THIS (TYP.) 4"1/4" (TYP.)23' - 5 3/4" (FRONTBAR FINISH PANEL) PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. DIEWALL THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO FRONT BAR FINISH PANEL ELEVATIONFINISH PANEL DETAIL NOT REFLECT ACTUAL SITE CONDITIONS. 12 NEITHER PARTY SHALL HAVE ANY OBLIGATION Scale: 3/4" = 1'-0"Scale: 6" = 1'-0" NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 Design Forum NOTES: 1. LOCATE PUMP WITHIN CORD LENGTH LIMIT. ORIENT WITH PUMP HEAD LEFT, Architects Inc. RIGHT AND AT BOTTOM. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE-TIGHTEN 700 W. Pete Rose Way, Suite 460Donald J. Rethman AS REQ'D PER ORIENTATION TO PROVIDE FRONT ACCESS TO FLOW ADJUSTMENT Cincinnati, OH 45203Architect In Charge SCREW. DO NOT ORIENT WITH PUMP HEAD ON TOP WITHIN CORD LENGTH LIMIT. Tel: (513) 421-2210License: AR19700147 NOTE: 1" X 2" CONTINUOUS 2. USE LOCKTITE ON ISOLATOR THREADS. DO NOT OVER TIGHTEN. ALL COMPONENTS FURNISHED BY GALVANIZED STEEL OTHERS AND INSTALLED BY G.C. ANGLE 3. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE-TIGHTEN AS REQ'D Design Forum UNLESS NOTED OTHERWISE. FOR PUMP ORIENTATION. 18139 - ESPRESSO SHROUD Engineering 4. BACKER BOARD ASSEMBLY (V401) INCLUDES: SOLID SURFACE COUNTERTOP FINISH: CP0002 4 3/4" 2" (1) BACKER BOARD FINISH: CP0002 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE (4)T'NUTS, 1/4-20 VENDOR MOUNTED Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 (8) WOOD SCREWS, #8 -1 1/4" 2' - 10" AFF (4) NEOPRENE ISOLATORS, KARAMAN RUBBER, RUBBER,K84-60 NEOPRENE BACKBAR COUNTERTOP (4) LOCK NUTS,1/4-20 NYLON (4) WASHERS, 1/4" FLAT 2'-2" AFF (ELEC. J-BOXES) 3" 5. ATTACH TO CABINET W/ SILICONE ADHESIVE & WOOD SCREWS, 4" X 4" ELECTRICAL J-BOXES SILICONE PERIMETER. MOUNTED TO WALL WITH INTERCONNECTING CONDUIT (2 EA.) BARISTA CABINET W/ X1001 - FINISH PANEL 1'-7" AFF (CW SUPPLY) CUP DISPENSER FINISH: WD0073 WOOD SLATS 1'-6" AFF (CWF SUPPLY) 18139 - ESPRESSO SHROUD 1'-5" AFF (HW SUPPLY) FINISH: CP0002 6" 18137 - FRONT BAR 11/01/17 09/01/17 DIE WALL AT BARISTA INTEGRATED BACK SPLASH MASTRENA PUMP ATTACH TO SHROUD/SPLASH FINISH TO 10" ALL PLUMBING LINES TO BE BACKER BOARD WITH MATCH COUNTERTOP, TYP. MOUNTED 1" (NOMINAL) ASSEMBLY COMPONENTS. VARIES: 1/4" PER FOOT FALL FROM WALL FOR CLEANING CORIAN COUNTERTOP ABS 2" WASTE LINE L FINISH: CP0002 10" X 10" BACKER BOARD CONTINUOUS METAL L ANGLE MOUNTED TO Y E PLYWOOD WALL, UNDER 34" MAX. A.F.F. REMOVABLE CABINET BACK W FINISHED CLADDING D MASTRENA PUMP ATTACH PANEL W/ PUMP MOUNT K 10" TO BACKER BOARD WITH P L ASSEMBLY COMPONENTS. 1 1/4" TILE BASE L 1/2" E 3 L 3 Z 6" ADJUSTABLE METAL LEGS E 0 FINISHED FLOOR A D6 FINISH PANELDIEWALL 6" 4 L H 4 E N I-5011 I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt 3" Z & , A L T H E DIEWALL ASSEMBLY AT BARISTAPUMP ATTACHMENTESPRESSO SHROUD SECTION S 0 M 345 7 Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 6" = 1'-0" 1 R 1 3 A 3 1 1C STORE #:8123 PROJECT #:25450-048 ISSUE DATE: 11/1/17 1 1/4" DESIGNER: LISA MACEDA R LEED AP: CORIAN PER FINISH 1/4" RADIUS TYP. CORIAN PER FINISH 1/4" DEEP DRIP PRODUCTION DESIGNER: PETER CHEETHAM SCHEDULE 1/2" SCHEDULEEDGE PER PLAN CHECKED BY: 1/4" RADIUS, TYP. +/- 3'-4" AFF Revision Schedule 1/2" TH. SOLID SURFACE BACKSPLASH RevDateByDescription 1 1/4" R 3/8" SOLID SURFACE COUNTER TOP C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 1/2" 1/2" MARIN PLY BASE SHEET TITLE: NOTE: FOR REF ONLY. MATCH NOTE: FOR REF ONLY. MATCH CABINET CABINET EXIST COUNTERTOP EDGE EXIST COUNTERTOP EDGE CASEWORK DETAILS DETAIL WHEN APPLICABLE. DETAIL WHEN APPLICABLE. AS SHOWN SCALE: SHEET NUMBER: TYP. CORIAN EDGE - FRONTLINEBACKSPLASH DETAIL AT SOLID SURFACETYP. CORIAN DRIP EDGE - FRONTLINE 678 Scale: 6" = 1'-0"Scale: 6" = 1'-0"Scale: 6" = 1'-0" I-5011 10/31/2017 6:24:16 PM NOTE: SHOP DRAWINGS TO BE APPROVED BY SB DESIGNER PRIOR TO FABRICATION. DT WINDOW DT EXTERIOR SHELF 8" R MOISTURE- 1" RESISTANT 1' - 0"3" C 2017 STARBUCKS COFFEE COMPANY 3'-0" AFF GYP BOARD B/O SILL TOP TILE FINISH AS SCHEDULED STARBUCKS COFFEE CX1013 HIDDEN SHELF COMPANY DT WINDOW SILL TOP SUPPORT FINISH: CP0002 3 3/4" WOOD TABLE TOP 2401 UTAH AVENUE SOUTH DT WINDOW (ABOVE) SEATTLE, WASHINGTON 98134 2" FACE OF WALLDT WINDOW SILL TOPFACE OF WALL (206) 318-1575 FINISH: CP0002 WOOD SHELF CX1013 THESE DRAWINGS AND SPECIFICATIONS ARE FINISH: WD0073 INTERIOR CONFIDENTIAL AND SHALL REMAIN THE SOLE 2 8" FINISH AS PROPERTY OF STARBUCKS CORPORATION, MENU BOARD WIRE TO PLUG MOLD SCHEDULED I-5012 WHICH IS THE OWNER OF THE COPYRIGHT IN MOUNTING THIS WORK. THEY SHALL NOT BE HARDWARE REPRODUCED (IN WHOLE OR IN PART), SHARED EXTERIORINTERIOR WITH THIRD PARTIES OR USED IN ANY MANNER 1 1/2" 8" ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN FLOOR BOX CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A METAL LEG BASE PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO 3' - 11 1/2" NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION TILE BASE AS EXTERIOR NOR LIABILITY TO THE OTHER (EXCEPT STATED SCHEDULED TILE FINISH AS ABOVE) UNTIL A WRITTEN AGREEMENT IS SCHEDULED FULLYEXECUTEDBYBOTHPARTIES METAL FRAMING STARBUCKS TEMPLATE VERSION i2017.08.25 AS REQUIRED Design Forum X1013 - DT SILL TOP PLANX1013 - DT SILL TOP SECTIONCOMMUNITY TABLE LEG PLANUPPER SHELF FIXING DETAIL 1234 Scale: 3/4" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 3" = 1'-0" Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 14' - 5" Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 FACE OF WALL Design Forum X1010 - MENU BOARD FRAME Engineering FINISH: WD0073 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE X1007 - BACKBAR SHELF Cincinnati, OH 45203Professional Engineer 7 License: PE10504904 Tel: (513) 421-2210 FINISH: WD0073 I-5012 I-5012 LED STRIP LIGHT 6 8" 14' - 9" (VERIFY) 11/01/17 09/01/17 X1007 - BACKBAR SHELF PLAN 5 Scale: 3/4" = 1'-0" 4 L I-5012 L Y E W D K 14' - 9" (VERIFY) P L MOISTURE- L E 3 RESISTANT L 3 MENU BOARD GYP BOARD Z E 5 1/2"12' - 0"2' - 3 1/2" 0 A D6 1 1/2" MENU BOARD MOUNTING TILE FINISH AS 4 HARDWARE L SCHEDULED H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt HIDDEN SHELF Z FACE OF WALL& , SUPPORT A L T H E 8'-0" AFF BACKBAR SHELF T/O BACKBAR SHELF S 0 1' - 9"2' - 0" FINISH: WD0073 M 7 1 R 1 X1007 - BACKBAR SHELF 3 A WOOD SHELF 3 FINISH: ED0073 1 1C FINISH: WD0073 LED STRIP LIGHT 2' - 4 1/4" STORE #:8123 1 1/2" 1 1/2" PROJECT #:25450-048 1"1 1/2" 6'-0" AFF LED STRIP LIGHT 8 ISSUE DATE: 11/1/17 8" B/O BACKBAR SHELF I-5012 DESIGNER: LISA MACEDA R LEED AP: TILE FINISH AS PRODUCTION DESIGNER: PETER CHEETHAM BACKBAR TILE FINISH AS SCHEDULED CHECKED BY: SCHEDULED (BEYOND) METAL FRAMING AS REQUIRED CHALKBOARDMENU BOARD LED STRIP LIGHT Revision Schedule (TYP.)(TYP.) RevDateByDescription X1007 - BACKBAR SHELF ELEVATIONX1007 - BACKBAR SHELF SECTIONSHELF FIXING DETAIL C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 678 Scale: 3/4" = 1'-0"Scale: 1 1/2" = 1'-0"Scale: 3" = 1'-0" SHEET TITLE: CASEWORK DETAILS AS SHOWN SCALE: SHEET NUMBER: I-5012 10/31/2017 6:24:22 PM NOTE: SHOP DRAWINGS TO BE APPROVED BY SB DESIGNER PRIOR TO FABRICATION. DT WINDOW R 4" C 2017 STARBUCKS COFFEE COMPANY 1/2" 2'-9 3/4" AFF STARBUCKS COFFEE B/O SILL TOP COMPANY I-5013 5 2401 UTAH AVENUE SOUTH CX1012 I-5013 SEATTLE, WASHINGTON 98134 DT WINDOW SILL TOP 4 (206) 318-1575 FINISH: CP0002 17' - 7" THESE DRAWINGS AND SPECIFICATIONS ARE FINISH AS CONFIDENTIAL AND SHALL REMAIN THE SOLE METAL BASE SCHEDULED PROPERTY OF STARBUCKS CORPORATION, FINISH: MT0011 WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER INTERIOR TABLE TOP ON OTHER PROJECTS OR EXTENSIONS TO THIS 2' - 0" EXTERIOR FINISH: WD0073 PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A ADA SIGNAGE PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. TILE BASE AS EQEQ NEITHER PARTY SHALL HAVE ANY OBLIGATION SCHEDULED 3' - 7 1/4" NOR LIABILITY TO THE OTHER (EXCEPT STATED 3' - 0 1/4" ABOVE) UNTIL A WRITTEN AGREEMENT IS 4' - 0" FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 X1012 - STOREFRONT SILL TOP SECTIONX1305 - ADA TABLE PLAN Design Forum 23 Scale: 1 1/2" = 1'-0"Scale: 1" = 1'-0" Architects Inc. 1' - 5" 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge Tel: (513) 421-2210License: AR19700147 4' - 0" 2' - 1" Design Forum 2 1/4"2 1/4" EQEQ 3' - 7 1/4" Engineering 2' - 0" 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 3' - 3" 1" TABLE TOP 1 3/4" 1 3/4" TABLE TOP 4 3/4" FINISH: WD0073 FINISH: WD0073 TABLE TOP SUPPORT FINISH: MT0028 1 1/4" METAL BASE TABLE BASE FINISH: MT0028 2' - 6"2' - 6" TABLE LEG 2' - 4 1/4" 2' - 3 1/4" FINISH: MT0028 FINISHED FLOOR 11/01/1709/01/17 1' - 7 1/2" FINISHED FLOOR 4' - 9" L L Y E 11' - 3 1/2" W D X1305 - ADA TABLE ELEVATIONX1305 - ADA TABLE SECTION K 2 45 P Scale:Scale: 1" = 1'-0" 1" = 1'-0" I-5013 L L E 3 L 3 Z E 0 A D6 4 L H E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z & , A L T H E S 0 M 7 1 R CX1012 1 3 A 3 STOREFRONT WINDOW 1 1C SILL TOP, FINISH: CP0002 STORE #:8123 (E) STOREFRONT PROJECT #:25450-048 WINDOW ISSUE DATE: 11/1/17 STOREFRONT WINDOW FACE OF WALL DESIGNER: LISA MACEDA SILL TOP, FINISH: CP0002 R LEED AP: X1012 C PRODUCTION DESIGNER: PETER CHEETHAM 2 CHECKED BY: I-5013 4 3/4" Revision Schedule 1' - 7 1/4" RevDateByDescription C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 4 3/4" SHEET TITLE: CASEWORK DETAILS 5' - 4"1' - 8 1/2" AS SHOWN SCALE: SHEET NUMBER: X1012 - STORE FRONT SILL TOP PLAN 1 Scale: 3/4" = 1'-0" I-5013 10/31/2017 6:24:26 PM (E) STEEL DECKING (E) STEEL BOLT DECKING IN BETWEEN VALLEYS OF DECKING. (E) STL PROVIDE PL WASHERS 1/4" X 2" X 3 PL WASHER 1/4" X 2" X 2" TRUSS 1/2" PER PLAN @ TOP & BOTT. OF CHORD R (E) STL C 2017 STARBUCKS COFFEE COMPANY SLOTTED DEFLECTION TRACK BTWN (E) TRUSS TRUSSES 6'-0" MAX SPAN PER PLAN PER SCHEDULE W/ 1 1/2" VERTICAL SLOTS, STARBUCKS COFFEE CONT SLOTTED DEFLECTION CONT. 33 MIL STUD TRACK COMPANY BLOCKING PER SCHEDULE W/ 1 1/2" VERTICAL PER DET 2/S-0002, TYP WALL PERPEND TO (E) STL TRUSS 2401 UTAH AVENUE SOUTH SLOTS, ATTACH TO 2x GWB SHEATHING PER ARCH W/ (3) #10x1 1/4" SCREWS SEATTLE, WASHINGTON 98134 (206) 318-1575 PARTITION WALL SCHEDULE STL STUD @ 16" O.C. PER SCHEDULE #8 SCREW EA SIDE DEFL TRACK SPANNING WALL HEIGHTSTUD SIZEDEFL TRACKBOT TRACK THESE DRAWINGS AND SPECIFICATIONS ARE CONT BOTTOM TRACK PER SCHEDULE W/ OF TRACK TO BTWN (E) JOISTS CONFIDENTIAL AND SHALL REMAIN THE SOLE STUD JST @ 4' O.C.54 MIL PROPERTY OF STARBUCKS CORPORATION, @ 8" O.C. STAGGERED, TYP 15 FEET362S137-3333 MIL33 MIL WHICH IS THE OWNER OF THE COPYRIGHT IN JST @ 6' O.C. 68 MIL (E) SLAB PER PLAN THIS WORK. THEY SHALL NOT BE 4" MIN, FIELD REPRODUCED (IN WHOLE OR IN PART), SHARED VERIFY JST @ 4' O.C.68 MIL WITH THIRD PARTIES OR USED IN ANY MANNER 33 MIL 20 FEET550S162-3333 MIL ON OTHER PROJECTS OR EXTENSIONS TO THIS JST @ 6' O.C. 97 MIL PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE JST @ 4' O.C.68 MIL 33 MIL 25 FEET600S200-4343 MIL INTENDED TO EXPRESS DESIGN INTENT FOR A JST @ 6' O.C. 97 MIL PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION TYP MTL STUD PARTITION WALL NOR LIABILITY TO THE OTHER (EXCEPT STATED 1 ABOVE) UNTIL A WRITTEN AGREEMENT IS Scale: 3/4" = 1'-0" FULLYEXECUTEDBYBOTHPARTIES STARBUCKS TEMPLATE VERSION i2017.08.25 1/4" X 2" X 3 1/2" @ TOP & BOTT. OF CHORD & ON BOTT. OF 2x 2 1/2" Design Forum FASTEN STRAPPING TO BLKG TYP PER SCHD, MAX SPAN 7'-0" THRU BOLT TO (2) 2X W/W/ #8 SCREWS @ 6" O.C. (E) TRUSS SEE SCHD FOR MAX NUMBER OF VERT STUD PER SUPPORT PL WASHERS 1/4"X2"X3 1/2" Architects Inc. PER PLAN TOP AND BOT, TYP 2X6 ALIGN W/ VERTICAL STUD 700 W. Pete Rose Way, Suite 460Donald J. Rethman CONT. TRACK BLKING @ OPENINGS & @ Cincinnati, OH 45203Architect In Charge PER SCHEDULE 4'-0" O.C. FIT TIGHT BETWEEN STUDS Tel: (513) 421-2210License: AR19700147 1 ±1 2x6 AS REQ'D. LOCATE TIGHT METAL WALL STUD (E) STEEL DECKING Design Forum TO TOP CHORD OF TRUSS 2 1/2" TYP ATTACH TO BRACE W/ STUD BRACING (3) #10X1 1/4" SCREWS. Engineering SHEATHING PER ARCH 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE STUD 362S137-33 362S137-33 BRACE @ 32" O.C. Cincinnati, OH 45203Professional Engineer License: PE10504904 Tel: (513) 421-2210 @ 16" O.C. W/ (4) #10 SCREWS TO STUD TYP MAX BRACE LENGTH 14'-0" 362S137-33 BRACE @ 32" O.C. W/ (4) #10 VALLEYS OF DECKING. PROVIDE PL WASHERS SCREWS TO STUD MAX BRACE LENGTH 1/4" X 2" X 3 1/2" @ TOP & BOTT. OF FASTEN STRAPPING TO EA. 12'-0", SEE DET OPP FOR BRACE TO CHORD & ON BOTT. OF 2x 33 MIL CONT TRACK STUD W/ (1) #8 (MIN.) SCREW. (E) JOIST ABOVE. BRACE WHERE W/ (2) #8 SCREWS OPEN CEILING OCCURS @ EACH STUD SOFFIT SUPPORT SCHEDULE SUSPENDED CEILING HORZ. BLKG/BRACING IS REQUIRED @ 48" O.C. EXISTING MAX # OF VERT STUD NUMBER VERTICALLY UNLESS WALL IS SHEATHED ON OR OPEN CEILING PER ARCH JOIST SPAN OF 2X6PER SUPPORT EACH SIDE. IF WALL IS SHEATHED ON ONE 11/01/17 09/01/17 5'-6" TO 7'-0"(3) 2X63 VERTICAL STUDS SIDE, THE STRAP IS NOT REQUIRED ON THE (4)#10 SCREWS SUSPENDED SIDE WITH SHEATHING. 43 MIL CONT TRACK, TYP (2) 2X6 @ CROSSING, 4'-0" TO 5'-6"CEILING 2 VERTICAL STUDS BLOCKING / STRAPPING IS REQUIRED IF LOAD TYP PER ARCH IS APPLIED BEFORE SHEATHING IS ATTACHED. 11'-0" MAX BULKHEAD PER ARCH, TYP BULKHEAD PER ARCH, TYPVERTICAL STUD @ 5 EQUAL SPACE, 2'-3" O.C. MAX CONT. CS-22 FLAT STRAPPING L OVER BLKG AS SHOWN. REQUIRED L 362S137-33 JOIST @ 16"O.C. ON ALL SIDES WITHOUT SHEATHING. Y E W D TYPICAL SOFFIT PARALLEL TO (E) TRUSS-ATYPICAL WALL BLOCKING BRACING K 23 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" P L L E 3 L 3 Z E 0 (E) STEEL DECKING A D6 4 L H E N PROVIDE PL WASHERS I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z (E) STEEL & , 1/4" X 2" X 3 1/2" @ TOP & DECKING A L BOTT. OF CHORD & ON BOTT. T H OF 2x E (E) STEEL 2X6 DECKING S 0 M TYP. 7 1 R 1 3 A (E) STL TRUSS 3 1 1C BRACING (E) STL TRUSS 1 STUD STORE #:8123 ±1 REMOVE (E) SOFFIT AS (E) STL TRUSS REQ'D. (E) SOFFIT CL OF ANGLE CLIP W/ BRACING PROJECT #:25450-048 362T150-33 W/ 1/2"Ø (E) PARTITION WALL TO REMAINS NUT IN BETWEEN THRU BOLT TO (2) 2X W/ STUD OR EXTERIOR WALL ISSUE DATE: 11/1/17 VALLEYS OF DECKING. 362S137-33 PL WASHERS 1/4"X2"X3 1/2" DESIGNER: LISA MACEDA @ 16" O.C. TYP TOP AND BOT, TYP R LEED AP: PRODUCTION DESIGNER: PETER CHEETHAM 362S137-33 BRACE @ 32" O.C. L3" X 3" X 3/16" TO CHECKED BY: BRACING W/ (4) #10 SCREWS TO STUD SPAN OVER (2) VALLEYS. 362S137-33 BRACE @ 32" O.C. W/ (4) #10 MAX BRACE LENGTH 14'-0" ATTACH TO BRACE W/ SCREWS TO STUD MAX BRACE LENGTH Revision Schedule (3) #10 SELF TAPPING 12'-0", SEE DET OPP FOR BRACE TO SCREWS 33 MIL CONT TRACK W/ (2) 33 MIL CONT TRACK (E) JOIST ABOVE. BRACE WHERE RevDateByDescription #8 SCREWS @ EACH W/ (2) #8 SCREWS OPEN CEILING OCCURS BRACE STUD @ EACH STUD AND #8 SCREW EA SIDE OF C:\\Users\\zach.scholl\\Documents\\Starbucks_131st TRACK SUSPENDED CEILING OR OPEN CEILING PER ARCH (4)#10 SCREWS @ CROSSING, SHEET TITLE: 43 MIL CONT TRACK, TYP SUSPENDED CEILING PER ARCH TYP ALIGN SHEATHINGS 11'-0" MAX CONNECTION DETAILS BULKHEAD PER ARCH, TYP VERTICAL STUD @ 5 EQUAL SPACE, 2'-3" O.C. MAX AS REQ'D BULKHEAD PER ARCH, TYP 362S137-33 JOIST @ 16"O.C.1" MAX 3/4" = 1'-0" SCALE: SHEET NUMBER: TYP SOFFIT PERPENDICULAR TO (E) TRUSSTYPICAL SOFFIT TO (E) WALLNEW SOFFIT TO (E) TRUSS 456 Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0"Scale: 3/4" = 1'-0" I-5014 10/31/2017 6:24:31 PM SPECIALTY EQUIPMENT SCHEDULE - "E" DATA DEVICE SCHEDULE - "A"CASEWORK SCHEDULE - "C" DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS COOLING AUDIO VISUALCABINET 101101FRIDGE REACH IN 1 DOOR RH - 29IN 735MMSB-GC 100172SPEAKER SURFACE MOUNTED BLACKSB-GC175743CABINET - SINK OR ICE - 15IN 380MMSB-GC 102672FRIDGE UNDERCOUNTER 1 DOOR - 27INSB-GC DATA175751CABINET - SINK OR ICE - 20IN 510MMSB-GC 685MM 187441EQUIPMENT RACK WITH LOCK - 24IN 610MMSB-GC175802CABINET - CBE SHELF - 29X14IN 735X355MM -SB-GC 110831FRIDGE REACH IN 2 DOOR - 51X35INSB-GC FLAT BLACK MT0028 1295X890MM POINT OF SALE 175811CABINET - CBE SHELF - 22X10IN 560X255MM -SB-GC 126182FRIDGE UNDERCOUNTER 1 DOOR WITHSB-GC 100754CUP LABELERSB-GC FLAT BLACK MT0028 SHELF - 27IN 685MM R 177401CABINET - 30IN 760MMSB-GC 136821FREEZER REACH IN 2 DOOR - 54IN 1370MMSB-GC 177414CABINET - 15IN 380MMSB-GC 175671WATER CHILLERSB-GC DATA DEVICE SCHEDULE - EXISTING C 2017 STARBUCKS COFFEE COMPANY 177421CABINET - DT POS UPPER CUBBY - 32INSB-GC EQUIPMENT 815MM DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 103122BREWER SOFT HEAT WARMING STANDSB-GC 177433CABINET - POS - 30IN 760MMSB-GC AUDIO VISUAL SINGLE STARBUCKS COFFEE 177441CABINET - POS BRIDGE - 22IN 560MMSB-GC 100051MUSIC SYSTEMEXIST 108562BREWER SERVER SOFT HEATSB-GC COMPANY 177451CABINET - DRAWER - 15IN 380MMSB-GC 100103MONITOR - 15IN 380MMEXIST 124072OVEN TURBOCHEF NEXT GENERATIONSB-GC 177473CABINET - TRASH - 15IN 380MMSB-GC 100135DT QUEUE CAMERAEXIST 2401 UTAH AVENUE SOUTH 125083BLENDER QUIET MODEL ON COUNTERSB-GC 177542CABINET - ESPRESSO CUBBY - 18IN 455MMSB-GC 100174SPEAKER SURFACE MOUNTED BLACKEXIST FOOD CASE SEATTLE, WASHINGTON 98134 181221CABINET - SINK OR ICE - 16IN 405MMSB-GC 100761AMPLIFIER - 14IN 355MMEXIST 162381FOOD CASE - ZEPHYR - 66IN 1675MMSB-GC (206) 318-1575 X10071CUSTOM BACKBAR SHELFSB-GCSEE DETAIL: 4/I-5012 DATA ICE THESE DRAWINGS AND SPECIFICATIONS ARE CAFE 100002PHONE 1 LINEEXIST 103441ICE - BIN DROP IN 90LB 40KGSB-GC CONFIDENTIAL AND SHALL REMAIN THE SOLE 122361CONDIMENT CART SINGLE TOP SOLIDSB-GC 100021COMPUTER MANAGER WORKSTATIONEXIST 105273ICE - BIN DROP IN 45LB 20KGSB-GC PROPERTY OF STARBUCKS CORPORATION, SURFACE 100071PRINTER MANAGER WORKSTATIONEXIST 108131ICE - MACHINE ICE1406HR REMOTE COOLEDSB-GC WHICH IS THE OWNER OF THE COPYRIGHT IN 123632MERCH BAY UNIT BACK PANEL SOLIDSB-GCNOT PROVIDED BY CASEWORK 100191WIDE AREA NETWORK HARDWAREEXIST 180291ICE - BIN B110SB-GC THIS WORK. THEY SHALL NOT BE VENDOR POINT OF SALE REPRODUCED (IN WHOLE OR IN PART), SHARED NITRO 131911MERCH BAY UNIT END PANELS METAL MESHSB-GCNOT PROVIDED BY CASEWORK WITH THIRD PARTIES OR USED IN ANY MANNER 100032POS - REGISTER WITH FULL SIZE CASHEXIST 145231TANK MOUNTING BRACKET SINGLESB-GC VENDOR ON OTHER PROJECTS OR EXTENSIONS TO THIS DRAWER 175881KEG DISPENSING SYSTEM - 27IN 685MM -SB-GCKIT INCLUDES UNDERCOUNTER 133741CONDIMENT CART SINGLE BASE FRAMESB-GCNOT PROVIDED BY CASEWORK PROJECT WITHOUT THE PRIOR WRITTEN 100082POS - REGISTER WITH COMPACT CASHEXIST WITH NONPLUMBED DRIP TRAYFRIDGE, TAPS, TRAY, AND TUBING VENDOR CONSENT OF STARBUCKS CORPORATION. DRAWER X15013KEGS FOR NITROSB-GCVD: DELFIELD; THESE DRAWINGS AND SPECIFICATIONS ARE 133771CONDIMENT CART SINGLE FINISH PANELSSB-GC 100144POS PRINTEREXIST 3 IN BOH - 3 IN FOH INTENDED TO EXPRESS DESIGN INTENT FOR A 133991CONDIMENT CART SINGLE METAL TOPSB-GCNOT PROVIDED BY CASEWORK 100221MONEY COUNTEREXIST OTHER PROTOTYPICAL STARBUCKS STORE (WHICH IS ASSEMBLYVENDOR 100296POS BANKEXIST SUBJECT TO CHANGE AT ANYTIME) AND DO 100912CUP DISPENSER TALL HOT VERTICALSB-GC 152212MERCH BAY UNIT - DARK WARM BROWNSB-GCNOT PROVIDED BY CASEWORK NOT REFLECT ACTUAL SITE CONDITIONS. 100752CUP LABELEREXIST 100992RESTROOM TOILET PAPER HOLDERSB-GC WD0001VENDOR NEITHER PARTY SHALL HAVE ANY OBLIGATION SECURITY 101722RESTROOM SEAT COVER DISPENSERSB-GC COUNTERTOP NOR LIABILITY TO THE OTHER (EXCEPT STATED 100041ALARM SYSTEMEXIST 101792HAND DRYER SURFACE MOUNTEDSB-GCWAREHOUSE 175771COUNTERTOP - CBE - RF - 111IN 2820MMSB-GC ABOVE) UNTIL A WRITTEN AGREEMENT IS 100281SAFE BASEEXIST 101821DT ESPRESSO TOPPING RAILSB-GC FULLYEXECUTEDBYBOTHPARTIES 177501COUNTERTOP - BREW - LF - 105IN 2665MMSB-GC 103842DIAPER CHANGING STATION HORIZONTALSB-GC 178091COUNTERTOP - HAND SINK WITH LOWSB-GC 103962CUP DISPENSER SHORT HOT VERTICALSB-GC SPLASH STAINLESS - 15IN 380MM STARBUCKS TEMPLATE VERSION i2017.08.25 WALL BASE SCHEDULE - "B" 107692RESTROOM GRAB BAR VERTICAL - 18INSB-GC 178301COUNTERTOP - POS - 82IN 2085MMSB-GC 455MM DESIGN IDLENGTHDESCRIPTIONRESP.COMMENTS 178381COUNTERTOP - WARMING - 60IN 1525MMSB-GC 107914CUP DISPENSER GRANDE VENTI COLDSB-GC FLOOR TRIM 181351COUNTERTOP - ESPRESSO WITH DUAL SINKSB-GC Design Forum VERTICAL AND ICE - 147IN 3735MM X12060"SCHLUTER SCHIENE E 100/V4ASB-GC 108554CUP DISPENSER GRANDE VENTI HOTSB-GC 181361COUNTERTOP - ESPRESSO CAP - 147INSB-GC TILE BASE VERTICAL Architects Inc. 3735MM 13101359' - 7 3/4"TILE BASE - GRAPHITE - 6X12IN 150X300MMSB-GCGROUT GR0007: MAPEI 47 - 700 W. Pete Rose Way, Suite 460Donald J. Rethman 108582CUP DISPENSER TALL COLD VERTICALSB-GC 181441COUNTERTOP - DT ESPRESSO - RF - 80INSB-GC CHARCOAL; LATICRETE 35 - MOCHA; Cincinnati, OH 45203Architect In Charge 108592RESTROOM GRAB BAR - 48IN 1220MMSB-GC 2030MM USE WITH OUTSIDE CORNER TILE Tel: (513) 421-2210License: AR19700147 12300 108622RESTROOM GRAB BAR - 36IN 915MMSB-GC X10031CUSTOM COUNTERTOP - NITRO AND HOP -SB-GCSEE DETAIL: 3/I-5010 102IN 2590MM 14856169' - 6 1/4"TILE BASE - COARSE DARK GREY - 6X12INSB-GCGROUT GR0007: MAPEI 47 - 109921PAPER TOWEL DISPENSER HALF SIZE -SB-GC 150X300MMCHARCOAL; LATICRETE 35 - MOCHA TRANSLUCENT GRAY X10051CUSTOM COUNTERTOP - MOP - 31IN 787MMSB-GCSEE DETAIL: 4/I-5010 Design Forum 111153SOAP DISPENSER SINK MOUNTEDSB-GC X10061COUNTERTOP - DT POS - 118IN 2998MMSB-GCSEE DETAIL: 2/I-5010 133302MOBILE CUP DISPENSER CADDYSB-GC INTERIOR DOOR SCHEDULE - "D" X10081COUNTERTOP - BACKSPLASH - VARIABLESB-GC Engineering LENGTH 135842CUP DISPENSER TRENTA COLD VERTICALSB-GC 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE DESIGNCONST.DOORFRAMEFRAMEFIRE DIEWALL STORAGE Cincinnati, OH 45203Professional Engineer IDTYPEFINISHFINISHMATERIALRATING COUNTDESCRIPTIONRESP.COMMENTS License: PE10504904 Tel: (513) 421-2210 178311DIEWALL - POS - 82IN 2085MMSB-GC 101492DT LID SHELF WALL MOUNTEDSB-GC 101902DOOR - SINGLETYPE EWD0073X1202-SGMTLNAGC-GCREFER RESTROOM 181371DIEWALL - ESPRESSO - 147IN 3735MMSB-GC 10293110 COMP LOCKEREXIST FLUSH - 36INDOOR (TYPE E) AND X10021CUSTOM DIEWALL - NITRO AND HOP - 101INSB-GCSEE DETAIL: 1/I-5010 104165WORKROOM WIRE SHELVINGSB-GC HARDWARE SET #6 2565MM 104625WORKROOM WIRE SHELVING POSTSSB-GC FIT KIT 106981MOP RACK WITH 3 HOLDERSSB-GC FURNITURE SCHEDULE - "F" 178941FIT KIT - CABINET FILLER PANELSB-GC 11104110 COMP LOCKER BASEEXIST OTHER 133261PRE WASH STATION - 36IN 915MMSB-GC DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS 111422CORBEL SUPPORT - 24IN 610MMSB-GC 156991PARTNER WORK CENTERSB-GC CHAIR 111553ESPRESSO MACHINE PUMP MOUNT - 10X10INSB-GC 172551PASTRY TRAY CART - 60IN 1525MMSB-GC 1785318CHAIR - CAFE ANGLED BACK WITH WOVENSB-GC 255X255MM 172641ROLLING PASTRY TRAY THAW RACK -SB-GC SEAT - BLACK AND GREY ROPE MT0028 F0195 178291FRENCH CLEAT - VARIABLE LENGTHSB-GCDESIGNER TO VERIFY QUANTITY. 20X26IN 510X660MM 178776CHAIR - STOOL 16IN 405MM TURNED WOOD 1SB-GC PROVIDE OVERALL LENGTH 11/01/1709/01/17 175681BRACKET FOR WATER CHILLERSB-GC - WHITE OAK WD0073 REQUIRED : 2'- 6" 181591WORKROOM SHELVING WITH TANK BRACKETSB-GC 179844BANQUETTE - FRAMED CUSHION - 69INSB-GC 181391ESPRESSO SHROUD - 147IN 3735MMSB-GC - 36IN 915MM 1755MM - WARM BROWN NATURAL F0055 181453COUNTERTOP SUPPORT LEG 1810642CHAIR - CAFE JULIE - WHITE OAK WD0073SB-GC X10125WINDOW SILL TOPSB-GCSEE DETAIL: 1/I-513 181128CHAIR - STOOL BAR HEIGHT JULIE - WHITESB-GC L X10131DT WINDOW SILL TOPSB-GCSEE DETAIL: 1/I-5012 OAK WD0073 SPECIALTY EQUIPMENT SCHEDULE - EXISTING L X10142CUSTOM WOODEN PORTALSB-GCSEE DETAIL: 14/I-5005 183186CHAIR - LOUNGE ARMLESS TUFTED CUSHIONSB-GC Y PANEL E WITH METAL FRAME - WARM BROWN DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS W X10011CUSTOM - FRONTBAR FINISH PANEL - 281INSB-GCSEE DETAIL: 1/I-5010 NATURAL F0055 COOLING D 7137MM K DESK 102673FRIDGE UNDERCOUNTER 1 DOOR - 27INEXIST RAILING P 101231DESK - MANAGERS WORKSTATION -SB-GC L 685MM X12151CUSTOM CORNER TRIMGC-GCPROVIDED BY CASEWORK VENDOR 60X30X30IN 1525X760X760MM - ALMOND L 110831FRIDGE REACH IN 2 DOOR - 51X35INEXIST E 3 (LOCATED @ CAFÉ): LAMINATE L 1295X890MM 3 TOTAL OVERLAL LENGTH-10' - 0" IN Z 106051DESK - MANAGERS WORKSTATIONSB-GC E 0 126181FRIDGE UNDERCOUNTER 1 DOOR WITHEXIST (26039MM) KEYBOARD TRAY - BLACK PLASTIC A D6 SHELF - 27IN 685MM 108091DESK - MANAGERS WORKSTATION SHELVESSB-GC 4 136821FREEZER REACH IN 2 DOOR - 54IN 1370MMEXIST L H WALL MOUNTED - ALMOND LAMINATE EQUIPMENT E N MIRROR I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt Z 103121BREWER SOFT HEAT WARMING STANDEXIST & , 143502MIRROR - RESTROOM ANGLED- 18X36INSB-GC SINGLE A L 455X915MM CW FINISH - NCS T 107462BREWER DUAL SOFT HEATEXIST H E OTHER 108081GRINDER DITTING KR1203EXIST S 0 107562COAT HOOK 2 PRONGSB-GC@ RESTROOMS M FINISH 108565BREWER SERVER SOFT HEATEXIST 7 CODE LOCATIONDESCRIPTIONCOMMENTS 1 108201COAT HOOK STRIP - 46IN 1170MMSB-GC R 1 110701DISHWASHER SANITIZEREXIST CABINETS 3 TABLE A 3 125082BLENDER QUIET MODEL ON COUNTEREXIST DT POS UPPER CUBBYPLASTIC LAMINATE - GRAPHITEPL0003 121944TABLE - BASE FIXED DOME ACCENT ANDSB-GC 1 1C 126943ESPRESSO MACHINE MASTRENAEXIST GUSSETS - 42IN 1065MM - HOT ROLLED UNDERCOUNTER CABINET BACKBARPLASTIC LAMINATE - GRAPHITEPL0003 OTHER STEEL MT0011 UNDERCOUNTER CABINET FRONTBARPLASTIC LAMINATE - GRAPHITEPL0003 STORE #:8123 103141SCALE DIGITAL WITH ADJUSTABLE DISPLAYEXIST 1652012TABLE - BASE CAFE DOME ACCENT - 18X28INSB-GC UNDERCOUNTER CABINET INTERIORPLASTIC LAMINATE - ALMOND MOUNT PROJECT #:25450-048 455X710MM - HOT ROLLED STEEL MT0011 CAFE 105011FIRE EXTINGUISHEREXIST 173407TABLE - CAFE METAL PEDESTAL BASESB-GC ISSUE DATE: 11/1/17 CONDIMENT CART TOPCOMPOSITE - WHITE WITH VEININGCP0002 SQUARE - 24IN 610MM - BLACK MT0028 109471SOAP DISPENSER WALL MOUNTEDEXIST DESIGNER: LISA MACEDA COUNTERTOPS - BACKBAR R 173412TABLE - ACCESSIBLE METAL WITH TAPEREDSB-GC 109771PAPER TOWEL DISPENSER FULL SIZE -EXISTLEED AP: DT POS ,DT ESPRESSO AND BACKBARCOMPOSITE - WHITE WITH VEININGCP0002 LEGS - 36X24IN 915X610MM - BLACK MT0028 TRANSLUCENT GRAY PRODUCTION DESIGNER: PETER CHEETHAM COUNTERTOPS CHECKED BY: 176448TABLE - TOP ROUND - 24IN 610MM - WHITESB-GC STORAGE HAND SINK COUNTERTOPSTAINLESS STEEL - BRUSHED#4 BRUSHED OAK WD0073 102222WIRE SHELF GRID AT SINKEXIST 16GA SST 176458TABLE - TOP SQUARE - 24IN 610MM - WHITESB-GC 10293110 COMP LOCKEREXIST Revision Schedule WARMING, BREW, AND CBECOMPOSITE - WHITE WITH VEININGCP0002 OAK WD0073 104166WORKROOM WIRE SHELVINGEXIST COUNTERTOP 184062TABLE - COMMUNITY CAFE HEIGHT ANGLESB-GC RevDateByDescription 104626WORKROOM WIRE SHELVING POSTSEXIST COUNTERTOPS - FRONT BAR BASE - 10 SEAT NARROW - WITH POWER 108381ROLLING WIRE CART FOR 3 COMP SINKEXIST NITRO, HOP, ESPRESSO AND POSCOMPOSITE - WHITE WITH VEININGCP0002 WHITE OAK WD0073 COUNTER TOPS11104110 COMP LOCKER BASEEXIST X13052CUSTOM - ADA TABLE - ACCESSIBLE WITHSB-GCSEE DETAIL: 3/I-5013 C:\\Users\\zach.scholl\\Documents\\Starbucks_131st 138341BASE - 24X18IN 610X455MMEXIST FINISH PANELS NARROW METAL FRAME - WD0049 CONDIMENT CART FINISH PANELSWOOD - VERTICAL SLAT WITH REVEAL -WD0073 WINDOW TREATMENT MAD100 127169ROLLER SHADE - CHARCOAL WOVEN F0049SB-GCBLIND EXPRESS ESPRESSO, HOP, NITRO AND POSWOOD - VERTICAL SLAT WITH REVEAL -WD0073 RESPONSIBILITY LEGEND (1) 1'-3" LENGTH SHEET TITLE: (FRONT BAR) FINISH PANELSMAD100 (1) 1'-5" LENGTH (2) 2'-5" LENGTH SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR FINISH PANEL METAL TRIMHOT ROLLED STEELMT0011 SCHEDULES (2) 3'-0" LENGTH OTHER (4) 4'-7" LENGTH SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS D/T WINDOW SILLCOMPOSITE - WHITE WITH VEININGCP0002 X14051CUSTOM ROLLER SHADES - CHARCOALSB-GCFIT TO CURVATURE OF WINDOW. SEE NO SCALE SCALE: ENGINE SOFFIT WOOD PLANKWOOD - WHITE OAK - PLANKWD0073MAD100 GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY WOVEN F0049ELEVATION 1/I-2101 ESPRESSO SHROUDCOMPOSITE - WHITE WITH VEININGCP0002 GENERAL CONTRACTOR X14061CUSTOM ROLLER SHADES - CHARCOALSB-GCFIT TO CURVATURE OF WINDOW. SEE SHEET NUMBER: WOOD CLADDINGWOOD - VERTICAL SLAT WITH REVEAL -WD0073 WOVEN F0049ELEVATION 1/I-2101 MAD100 NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS X14071CUSTOM ROLLER SHADES - CHARCOALSB-GCFIT TO CURVATURE OF WINDOW. SEE DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION I-6001 WOVEN F0049ELEVATION 1/I-2101 10/31/2017 6:24:43 PM GRAPHICS AND ARTWORK SCHEDULE - "G"PLUMBING FIXTURE SCHEDULE - EXISTINGSITE SCHEDULE - "Y" DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTSDESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS GRAPHICS - ARTWORKFAUCETEXTERIOR MENU X1401117657; FRAMED WITH NO MAT; PAPER TYPE:SB-GCSEE ELEVATION 2/I-2101; BY GFX104471FAUCET - PRE RINSE SPRAYER WALLEXIST140301MENU BOARD - DT DIGITAL ORDER SCREENSB-SBREFER DETAIL: 6/A-1003 PAPER 1; FRAME: LARSON-JUHL N11719MOUNTEDPOST - FLAT BLACK MT0028 FROSTED WALNUT 1/4" SPACER; OVERALL 108041FAUCET - PRE RINSE SWING SPOUTEXIST141161MENU BOARD - DT DIGITAL ORDER SCREEN -SB-SBREFER DETAIL: 6/A-1003; FOOTING SIZE: 45" W X 45" H; METAL FRAME FLAT BLACK MT0028AND CONDUIT BY GC 135881FAUCET - HAND SINK WALL MOUNTEDEXIST THICKNESS: 1/4" 141191MENU BOARD - DT 5 PANEL FREESTANDING -SB-SBREFER DETAIL: 1/A-1003 FILTER X1402117659; FRAMED WITH NO MAT; PAPER TYPE:SB-GCSEE ELEVATION 2/I-2101; BY GFX 108X65IN 2745X1650MM - FLAT BLACK MT0028 R 125011FILTER - RO SYSTEM 600GPDEXIST PAPER 1; FRAME: LARSON-JUHL N11719 141201MENU BOARD - DT PRE MENUSB-SBREFER DETAIL: 3/A-1003 125071FILTER - RO SYSTEM 40GAL STORAGE TANKEXIST FROSTED WALNUT 1/4" SPACER; OVERALL C 2017 STARBUCKS COFFEE COMPANY FREESTANDING - 36X65IN 915X1650MM - FLAT SIZE: 45" W X 45" H; METAL FRAME128961FILTER - BRINE TANKEXIST BLACK MT0028 THICKNESS: 1/4" 128992FILTER - POLY GLASS VESSELEXIST 157001MENU BOARD - DT DIGITAL ORDER SCREENSB-SBREFER DETAIL: 8/A-1003 STARBUCKS COFFEE X1403117681; PRINTED ON DREAMSCAPE CANVASSB-GCSEE ELEVATION: 3/I-2101; BY GFX 130821FILTER - WATER SOFTENER TWINEXIST CONTROL BOX AS WALLCOVERING; BACKGROUND: WHITE; SINK OTHER COMPANY ART: BLACK; OVERALL SIZE: 45' -2" W X 9'- 3" 132641SINK - 3 COMP WORK SST - 93IN 2350MMEXIST 100201DT WINDOW SHELF - 48IN 1205MM - SSTSB-GCSEE DETAIL: 4/A-1003 ; READY H 2401 UTAH AVENUE SOUTH 146881SINK - HAND WITH SIDE SPLASH WALLEXIST ACCESS - MODEL 275 SHELF X14041CUSTOM COMMUNITY BOARD; FRAMEDSB-GCSEE ELEVATION: 1/I-2101; BY GFX SEATTLE, WASHINGTON 98134 MOUNTED SST 100421BIKE RACK HOOPSB-GCREFER DETAIL: 9/A-1004 MAGNETIC COMMUNITY BOARD; FRAME: (206) 318-1575 413677, NATURAL MAPLE;140931DT WAYFINDING GRAPHIC ORDER POINTGC-GCSEE DETAIL: 11/A-1004; ENNIS FLINT - OVERALL SIZE: 3' - 0" W X 4' - 0" HSTAR PATTERN - WHITESTARBUCKS DRIVE THROUGH, THESE DRAWINGS AND SPECIFICATIONS ARE DESIGN # 14-110; 336.475.6600 PAINT SCHEDULE GRAPHICS - INTERIOR MENU CONFIDENTIAL AND SHALL REMAIN THE SOLE 140951DT WAYFINDING GRAPHIC EXIT ARROW -GC-GCSEE DETAIL:7/A-1004; ENNIS FLINT - 128375MENU BOARD - 1 FRONT PANEL INSERTSB-GC PROPERTY OF STARBUCKS CORPORATION, COLOR CODEDESCRIPTIONLRVRESP.COMMENTS WHITESTARBUCKS DRIVE THROUGH STYLE WHICH IS THE OWNER OF THE COPYRIGHT IN DIRECTIONAL ARROWS; DESIGN # SW6165SW - 616524GC-GCUSE PRIMER CP-1 128381MENU BOARD - DAILY OFFERINGSB-GC THIS WORK. THEY SHALL NOT BE 14-020-03 SW7005Paint - SW7005 PURE WHITE84GC-GCUSE PRIMER CP-1 CHALKBOARD FRONT PANEL RECTANGULAR REPRODUCED (IN WHOLE OR IN PART), SHARED 141011DT WAYFINDING GRAPHIC ENTRY ARROW -GC-GCREFER DETAIL: 6/A-1004; ENNIS FLINT SW9138SW - STARDEW43GC-GCUSE PRIMER CP-1 WITH THIRD PARTIES OR USED IN ANY MANNER 128396MENU BOARD - UNIVERSAL MOUNTINGSB-GC GREEN- STARBUCKS DRIVE THROUGH ON OTHER PROJECTS OR EXTENSIONS TO THIS X1202-ESCUSTOM SCUFF MASTER PAINT TO MATCH -GC-GCUSE PRIMER CP-1 HARDWARE FOR FRONT PANELS DIRECTIONAL ARROWS; DESIGN # P577 - EGGSHELLPROJECT WITHOUT THE PRIOR WRITTEN GRAPHICS - OTHER 14-020-03 CONSENT OF STARBUCKS CORPORATION. X1202-SGCUSTOM SCUFF MASTER PAINT TO MATCH -GC-GCUSE PRIMER CP-1 107532RESTROOM SIGN SET ACCESSIBLESB-GC 141031BOLLARD NONILLUMINATED SQUARE - FLATGC-GCREFER DETAIL: 1/A-1004 THESE DRAWINGS AND SPECIFICATIONS ARE P577 - SEMIGLOSS 115261BULLETIN BOARD - 36X24IN 915X610MMSB-GC BLACK MT0028 INTENDED TO EXPRESS DESIGN INTENT FOR A 126801EDUCATION DISK - MUGSSB-GCDUGGAL PROTOTYPICAL STARBUCKS STORE (WHICH IS 143234DT WAYFINDING GRAPHIC DIRECTIONALGC-GCREFERENCE PAINT P936 FOR SUBJECT TO CHANGE AT ANYTIME) AND DO DOUBLE ARROW - GREENSPECIFICATIONS; REFER DETAIL: 126881EDUCATION DISK RECYCLESB-GCDUGGAL NOT REFLECT ACTUAL SITE CONDITIONS. 8/A-1004 126892EDUCATION DISK - HAND DRYERSB-GCDUGGAL NEITHER PARTY SHALL HAVE ANY OBLIGATION 143244DT WAYFINDING GRAPHIC DIRECTIONALGC-GCREFERENCE PAINT P935 FOR 142981EDUCATION DISK - GROUNDS FOR YOURSB-GCDUGGAL WALL TREATMENT (AREA) SCHEDULE - "Q"NOR LIABILITY TO THE OTHER (EXCEPT STATED DOUBLE ARROW - WHITESPECIFICATIONS; REFER DETAIL: GARDEN ABOVE) UNTIL A WRITTEN AGREEMENT IS 8/A-1004 144032EDUCATION DISK - WATER LOW FLOWSB-GCDUGGAL DESIGN IDAREADESCRIPTIONRESP.COMMENTS FULLYEXECUTEDBYBOTHPARTIES UMBRELLA EXTERIOR 121473UMBRELLA - BASE FOR CANOPY - BLACKSB-GC STARBUCKS TEMPLATE VERSION i2017.08.25 X12107 SFBRICK - NATURALGC-GCCOLOR MATCH TO EXISTING PRIOR MT0028 TO CONSTRUCTION. CONTACT: MATT LIGHTING FIXTURE SCHEDULE - "L" 166283UMBRELLA - WITHOUT VALANCE - 6FT 183CMSB-GC MYER - EDGEWOOD BUILDING - GREY CANVAS F0177 SUPPLY 317-525-8718 DESIGN IDCOUNTDESCRIPTIONRESP.BULBCOMMENTS Design Forum PLASTIC EXIT 114691961 SFFRP - WHITEGC-GCMARLITE OR EQUAL 116113EMERGENCY EXIT LIGHT - WHITESB-GCLED 5W LOW ENERGYGREEN Architects Inc. TILE OR EQUALLETTERING 700 W. Pete Rose Way, Suite 460Donald J. Rethman 12205131 SFTILE - MOTTLED WHITE - 2X8IN 50X205MMSB-GCGROUT GR0002: MAPEI - 93 WARM 116491EMERGENCY LIGHT DOUBLE - WHITESB-GCCED; GREEN Cincinnati, OH 45203Architect In Charge GREY; LATICRETE - 90 LIGHT PEWTER LETTERING Tel: (513) 421-2210License: AR19700147 WALL TREATMENT (LENGTH) SCHEDULE- "R" 14694194 SFTILE - OCEANSIDE BLUE - 2X8IN 50X200MMSB-GCGROUT: MAPEI - 103 COBBLESTONE OTHER 18311401 SFTILE - OLIVE DRAB BURLAP TEXTURE -SB-GCGROUT GR0007: MAPEI - 47 148952LED PICTURE LIGHT TRADITIONAL - 36INSB-GCINTEGRATED LED DESIGN IDLENGTHDESCRIPTIONRESP.COMMENTS 12X24IN 300X600MMCHARCOAL; LATICRETE - 35 MOCHA 915MM - BRONZE Design Forum TRIM WALL COVERING RECESSED CAN X10150"SCHLUTER JOLLY A 100 ACGSB-GCSEE DETAIL: 10/I-5005 33'-4" 17779421 SFWALL TEXTURE - BASKET WEAVESB-GCPAINT FINISH: SW9138 1145844CAN - RECESSED HOUSING ADJUSTABLE -SB-GC(1) 14518 - LED PAR 30 X120362' - 6 3/4"SCHLUTER JOLLY A 100 ACGSB-GCLOCATION: RESTROOMS; SEE DETAIL Engineering 5IN 125MM - NEW CEILING850LM NFL WHITE, OR 17794166 SFVINYL - WALL COVERING - TAUPE BASKETSB-GC 2/I-5003 700 W. Pete Rose Way, Suite 460Timothy L. Raberding, PE EQUAL WEAVE TEXTURE X12070"SCHLUTER INDEC IN 100 ACGSB-GCLOCATION: BEVERAGE PREP; SEE Cincinnati, OH 45203Professional Engineer License: PE10504904 1286919CAN - RECESSED TRIM BAFFLE - 5IN 125MM -SB-GC Tel: (513) 421-2210 X1201444 SFDREAMSCAPE WALLCOVERING / ARTSB-GC DETAIL: 22'-6" WHITE WOOD CLADDING 1324244CAN - RECESSED TRIM ADJUSTABLE GIMBALSB-GC WD0073129 SFWOOD - WHITE OAK WD0073 MAD100SB-GCWOOD CLADDING RING - 5IN 125MM - WHITE 1382719CAN - RECESSED INTEGRATED LED HOUSINGSB-GC - 5IN 125MM - 900LM NEW CEILING SCONCE BULB SCHEDULE - "L" 143592SCONCE - PRISMATIC GLASS SHADE - CLEARSB-GCINTEGRATED LED STRIP DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS EXTERIOR SIGNAGE SCHEDULE - "S" 1474323STRIP - LED WALL WASHER - 37IN 940MM -SB-GCINTEGRATED LED@ DEMISING LAMP SILVERWALL AND 1451844LED PAR 30 850LM 2700K NFL - WHITESB-GC DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS BACKBAR 11/01/17 09/01/17 SIGNAGE - DRIVE THRU TROFFER 140911SIGN - DT DIRECTIONAL EXIT SIGNSB-SBEXISTING FOOTING & CONDUIT, SIGN 150573TROFFER - LED RECESSED - 24X48INSB-GCINTEGRATED LEDCED ILLUMINATED ARROW SERIES - 46IN 1170MM(SB); SEE DETAIL:4/A-1004 600X1200MM - WHITE - 3900LM 141061SIGN - DT CLEARANCE BAR ARROW SERIESSB-SBEXISTING FOOTING & CONDUIT, SIGN FREESTANDING(SB); SEE DETAIL: 2/A-1004 L L PLUMBING FIXTURE SCHEDULE - "P" Y E DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS W D DRAIN K 1029418DRAIN - FLOOR SINK SQUARE - 12IN 305MMSB-GC P L FLOOR TREATMENT SCHEDULE - "T" 1072610DRAIN - GRATE HALF SQUARE - 12IN 305MMSB-GC L E 3 X01003FLOOR DRAIN 6"GC-GCZURN ZN415B L 3 DESIGN IDAREADESCRIPTIONRESP.COMMENTS Z EQUIPMENT E 0 PLASTIC 175641BLENDER PITCHER RINSER WITH SENSORSB-GC A D6 X120313 SFHELIX Z1 - U/V RESISTANTE PVC/NBRSB-GCRECESSED TAPERED ANGLE FRAME 4 FAUCET L FRAME, COLOR: BLACK COMPOUND - 12" x 9" x 1/2" DEEP WITH H 101521FAUCET - DOUBLE LABORATORY WITH BENTSB-GC HIDDEN INTERLOCKING CONNECTOR E N I & Hazel Dell Pkwy IN_2017_Zach.Scholl.rvt RISER SPOUT Z TILE & , 101533FAUCET - WATER TOWER - 12IN 305MMSB-GC A 122030 SFTILE - GRAPHITE - 12X24IN 300X600MMSB-GCGROUT GR0008: MAPEI 10 - BLACK; L 102154FAUCET - DOUBLE LABORATORY WITH SWINGSB-GC T LATICRETE 45 - RAVEN H E SPOUT 14855572 SFTILE - COARSE DARK GREY - 12X24INSB-GCGROUT GR0007: MAPEI - 47 S 0 M 105973FAUCET - SINGLE HANDLESB-GC 300X600MMCHARCOAL; LATICRETE - 35 MOCHA 7 1 R 108743FAUCET - HOT WATER DISPENSERSB-GC 177931941 SFTILE - WARM GREY CEMENT PATTERN -SB-GCGROUT GR0007: MAPEI - 47 1 3 A GOOSENECK 24X24IN 600X600MMCHARCOAL; LATICRETE - 35 MOCHA 3 109221FAUCET - MOP SINK WALL MOUNTED 1 1C 110033FAUCET - DIPPERWELLSB-GC 175691FAUCET - WARE RINSER IN COUNTER -SB-GC STORE #:8123 24X9IN 600X235MM PROJECT #:25450-048 175721FAUCET - TAP SINGLE HANDLESB-GC CEILING TREATMENT SCHEDULE - "U" ISSUE DATE: 11/1/17 FILTER DESIGNER: LISA MACEDA 131491FILTER - PRESSURE GAUGE R DESIGN IDAREADESCRIPTIONRESP.COMMENTS LEED AP: OTHER PRODUCTION DESIGNER: PETER CHEETHAM OTHER 178511CHILLED WATER CONDUIT - 60FT 1829CMSB-GC CHECKED BY: 1051764 SFACT - WHITE - 2X2FT 61X61CMGC-GCARMSTRONG KITCHEN ZONE SINK 1130224 SFACT - WHITE - 2X4FT 61X122CMGC-GCARMSTRONG KITCHEN ZONE 101162SINK - RESTROOM WALL MOUNTEDSB-GC Revision Schedule X1207265 SFACT - MATCH TO EXISTING - 24 X 48FTGC-GCARMSTRONG KITCHEN ZONE 105491SINK - RINSE DROP IN SST - 12X20INSB-GC 61X122CM 305X510MM RevDateByDescription X12081415 SFARMSTRONG - 2X4FT 61X122CM; CIRRUSGC-GC 109951SINK - MOP - 24X24IN 610X610MM SECOND LOOK: 511 WHITE; 6"X48" LINEAR 128071SINK - UTENSIL RINSE WITH GRATE SST - LH -SB-GC PLANK LOOK PANEL 14X20IN 355X510MM C:\\Users\\zach.scholl\\Documents\\Starbucks_131st WOOD CLADDING 128082SINK - UTENSIL RINSE WITH GRATE SST - RH -SB-GC WD007336 SFWOOD - WHITE OAK WD0073 MAD100SB-GCWOOD CLADDING RESPONSIBILITY LEGEND 14X20IN 355X510MM 175651SINK - RINSE WITH DRAINBOARD - 15X27INSB-GC SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL CONTRACTOR 380X685MM SHEET TITLE: 176321SINK - STACKED DRAINBOARD - 15IN 380MMSB-GCSB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS SCHEDULES 176501SINK - DRAIN TRAY - 9X6IN 230X150MMSB-GC GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY 187431SINK - PREP STATION - 36X24IN 915X610MM GENERAL CONTRACTOR TOILET NO SCALE SCALE: X01012TOILET - TANKLESS EFFICIENT SINGLE FLUSHGC-GCAMERICAN STANDARD 3461.001 NOTE:ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS X01022TOILET - FLUSH VALVE AUTOMATICGC-GCAMERICAN STANDARD 6047.111 (1.1 DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION SHEET NUMBER: EFFICIENT SINGLE FLUSHGPF) I-6002 10/31/2017 6:24:58 PM ABBREVIATIONSVALVESPIPINGGENERAL PLUMBING NOTES PLUMBING SYMBOL LEGEND GENERAL 3PLTHIRD PARTY LOGISTICS1. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL SOIL, WASTE, AND VENT PIPING SANSANITARY OR WASTE PIPING BELOW SLAB SAN CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, PLUMBING CONTRACTOR SHALL PROVIDE VALVES WHERE INDICATED ON PLANSSOIL, WASTE, AND VENT PIPING 10" (254MM) AND SMALLER SHALL BE SERVICE VVENT PIPING AFFABOVE FINISHED FLOORCEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME WEIGHT, HUBLESS, CAST IRON PIPE, AND FITTINGS WITH NEOPRENE GASKET AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT AHJAUTHORITIES HAVING JURISDICTIONDAMAGED DURING THE COURSE OF WORK. AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB AND SPIGOT, ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. GWGWGREASE WASTE APPROXAPPROXIMATE PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS NOTED OTHERWISE)SERVICE WEIGHT CAST IRON SOIL PIPE AND FITTINGS BELOW GRADE WHERE 2. EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR AREA CBLCBLCOLD BEVERAGE LINE BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURERREQUIRED BY LOCAL CODES. SCHEDULE 40 ABS OR PVC PIPE AND FITTINGS BLDGBUILDINGUNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT CABINETS/DEVICES, WITH SOLVENT WELD MAY BE SUBSTITUTED FOR SOIL, WASTE, AND VENT PIPING SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR CDCDCONDENSATE DRAIN AND WHERE APPROVED BY STARBUCKS CONSTRUCTION MANAGER. IF ABOVE AND BELOW GRADE IF ALLOWED BY LOCAL AUTHORITY. ADHESIVES EASY ACCESS SUCH THAT CAN BE REACHED WITHOUT MOVING EQUIPMENT. CLGCEILINGROUTED THROUGH CABINETS, IT SHALL BE ROUTED TO MAXIMIZE STORAGE SHUT-OFF VALVES SHALL BE BALL TYPE. VALVES SHALL BE LISTED/APPORVEDSHALL NOT EXCEED A VOC CONTENT OF 510 G/L FOR PVC AND 325 G/L FOR ABS. R CW CWCOLD WATER PIPING CONSTCONSTRUCTIONSPACE AND BE PROTECTED FROM DAMAGE. ALL HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4" PER FOOT (21MM PER FOR USE PER AHJ AND CODE REQUIREMENTS. CWDOMESTIC COLD WATER METER) WHERE POSSIBLE BUT IN NO CASE LESS THAN 1/8" PER FOOT (10MM PER C 2011 STARBUCKS COFFEE COMPANY HWHOT WATER PIPING HW CXACOMMISSIONING AGENT3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR METER) WHERE ALLOWED & SIZED PER AHJ AND CODE. FWFWCOLD WATER FILTERED VALVES ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL COMPONENTS PROVIDE VALVES FOR WORKING PRESSURE IN WATER PIPING OF 125 PSI OR DEGDEGREESNEEDED WHETHER INDICATED OR NOT TO PROVIDE A COMPLETE AND COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS FOR CWNCWNCOLD WATER NANO FILTERED STARBUCKS COFFEE GREATER. UNLESS NOTED OTHERWISE, VALVES SHALL MEET THE FOLLOWING DTLDETAILOPERATING SYSTEM. OVERALL CASEWORK COMPONENT DIMENSIONING ON EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR SINKS. PROVIDE MINIMUM REQUIREMENTS: DNDOWNPLUMBING DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. PIPED DRAIN (P-TRAP AND VENT) TO SANITARY IF REQUIRED BY LOCAL CWSCWSCOLD WATER SOFTENED COMPANY DWG(S)DRAWING(S) JURISDICTION. VALVE TYPEDESCRIPTION 2401 UTAH AVENUE SOUTH 4. CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES TWTWTEMPERED WATER CHECK VALVE (UP TO 2" (51MM))BRONZE, HORIZ. SWING, EAEACHREQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CONSTRUCTION DOMESTIC WATER PIPING SEATTLE, WASHINGTON 98134 Y-PATTERN, RENEWABLE ROROREVERSE OSMOSIS WATER ECELECTRICAL CONTRACTORMANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. DOMESTIC WATER PIPING 2 1/2" (64MM) AND SMALLER SHALL BE COPPER TUBE (206) 318-1575 SEAT/DISC ELECELECTRICALALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH NON-LEAD, GASGASGAS PIPING EMEMERGENCYNOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM FROM ACTUAL NON-ANTIMONY SOLDER. PROVIDE TYPE "L" COPPER TUBE ABOVE GRADE AND THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL BALL VALVE (UP TO 3" (76MM))BRASS, FULL PORT, QUARTER REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS (E) OR (EX)EXISTINGBUILDING DIMENSIONS. TYPE "K" BELOW GRADE. RDRDREFRIGERANT DISCHARGE PIPING TURN THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE EXTEXTERIOR REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS RSRSREFRIGERANT SUCTION PIPING 5. THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK WITH GATE VALVE (UP TO 3" (76MM))BRONZE, NON-RISING STEM, CONDENSATE DRAINAGE PIPING PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS FDFLOOR DRAINOTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE SOLID WEDGE THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE FSFLOOR SINKOVER ALL OTHER DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR HANDLING UNITS AND STARBUCKS EQUIPMENT (REFER TO SCHEDULE). (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT BVBALL VALVE TEMP. AND PRESS. RELIEF VALVERATED FOR POTABLE WATER F&IFURNISH & INSTALLFIXTURES IN CASEWORK AND PLUMBING DETAILS. CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY HEATING STORAGE VESSEL W/OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) FLRFLOOR WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. SAFETY CERTIFICATION PER AHJ. FTFOOT/FEET6. ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM GVGATE VALVE FCOFLOOR CLEANOUTSTRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS). NATURAL GAS PIPING PRE-CHARGED, SEALED CHAMBER WATER HAMMER ARRESTOR FWFILTERED COLD WATER GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE. PROVIDE PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM. CH. VCHECK VALVE BACKFLOW PREVENTER (WHOLE-HOUSE)DOUBLE CHECK VALVE ASSEMBLY GCGENERAL CONTRACTOR Design Forum W/ UNION BALL VALVES AND GENERAL NOTES GFCIGROUND FAULT CIRCUIT INTERRUPTER HANGERS AND SUPPORTS SAFETY CERTIFICATION PER AHJ RVRELIEF VALVE GWGREASE WASTE THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS REQUIRED BACKFLOW PREVENTER (SINGLE DEVICE)DOUBLE CHECK VALVE ASSEMBLY Architects Inc. FOR EQUIPMENT AND MATERIAL. ALL HORIZONTAL RUNS OF PIPING SHALL BE SCOPE HRHOUR W/ SAFETY CERTIFICATION PER AHJ SUPPORTED BY PIPE HANGERS INSTALLED AS REQUIRED BY LOCAL CODES. 700 W. Pete Rose Way, Suite 460Donald J. Rethman THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A HBHOSE BIBB Cincinnati, OH 45203Architect In Charge HVACHEATING, VENTILATION, AND AIR CONDITIONING ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE REQUIRED TO PREVENT COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE CONTRACTOR License: Tel: (513) 421-2210 VACUUM RELIEF VALVEBRASS BODY AND STAINLESS HWHOT WATER SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED S SHALL FURNISH ALL LABOR, MATERIAL, AND EQUIPMENT RELATED TO THE STEEL INTERNALS HSHANDSINK SHOCK ABSORBER WITH GALVANIZED COATINGS; NON-METALLIC COATED FOR HANGERS IN DIRECT INSTALLATION OF THE PLUMBING WORK. HWSHOT WATER SUPPLY CONTACT WITH COPPER TUBING. PRESSURE REDUCING VALVEBRONZE, 25 TO 75 PSI REDUCE HWRHOT WATER RETURN PRESSURE RANGE AND SITE EXAMINATION Design Forum STRAINER CONNECTIONS UPSTREAM/DOWNSTREAM THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO PRESSURE GAUGES FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT IWINDIRECT WASTE Engineering EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT WCOWALL CLEANOUT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPING UP TO OF THE PLUMBING WORK. TRAP SEAL PRIMER 700 W. Pete Rose Way, Suite 460Timothy L. Raberding BRONZE, PRESSURE BASED LLLANDLORD AND INCLUDING 1-1/2" (38MM) FOR GAS PIPING. USE NON-LEAD, NON-ANTIMONY Professional Engineer Cincinnati, OH 45203 AUTOMATIC PRIMING LVLOW VOLTAGEFCOFLOOR CLEANOUT Tel: (513) 421-2210License: SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. STANDARDS SUPPLY WATER SERVICE EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE MAXMAXIMUM IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI THEN CLEANOUTS PROVISIONS OF CSA, ULC, ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS FDFLOOR DRAIN MCMECHANICAL CONTRACTOR PROVIDE A PRESSURE REGULATOR IN MAIN SUPPLY TO REDUCE WATER PROVIDE FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS OR APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. MDPMAIN DISTRIBUTION PANEL PRESSURE. PROVIDE BACKFLOW PREVENTION ON WATER SERVICE IF REQUIRED WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. IN AREAS MECHMECHANICAL 11/01/17 BY LOCAL CODES. WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE CLEANOUTS WITH FSFLOOR SINK CODES MEPMECHANICAL, ELECTRICAL, AND PLUMBING SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESILIENT (VINYL) ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL MFGMANUFACTURER FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF MINMINIMUM M THERMOSTATIC MIXING VALVE WMWATER METER TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES MSMOP SINK THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. WHERE PROVIDE A SINGLE THERMOSTATIC MIXING VALVE (TMV) LOCATED AT HOT AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. CONTRACTOR CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED POCCONNECT TO EXISTING WATER TANK AND SET FOR (OR AS REQUIRED BY AHJ) TO SERVE HAND SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT NLNIGHTLIGHT BEHIND CHROME PLATED ACCESS COVERS. SINKS. MIXING VALVE TO BE INSTALLED PER MANUFACTURER REQUIREMENTS ANY EXTRA COST TO STARBUCKS. NTSNOT TO SCALE WITH CHECK VALVES AT SUPPLY LINES. INSTALLATION PERMITS AND FEES PCPLUMBING CONTRACTOR INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND PSPREP SINK FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" (25MM) OF CLEANING INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK. POCPOINT OF CONNECTION INSULATION SPACE ALL AROUND PIPING, INCLUDING ANY ADDED PIPING INSULATION. PMPROJECT MANAGER INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. WARRANTY REFREFERENCE INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WATER PIPING THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE Revision Schedule REQUIRE(D) WALLS, GYPSUM BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS. PROVIDE THERMAL INSULATION ON ALL HOT WATER, COLD WATER, AND FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE RevDateDescription REVREVISION SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRE HORIZONTAL WASTE PIPING IN CEILING SPACES, AND ON ALL COLD WATER (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL STOPPING SEALANT MATERIAL PER CODE REQUIREMENTS. UNDERGROUND PIPING IN CASEWORK AND BAR AREAS. USE SELF SEALING CLOSED CELL FOAM REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT SHTSHEET WATER AND SEWER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A OR JACKETED FIBERGLASS INSULATION WITH MANUFACTURERS APPROVED CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE SPECSSPECIFICATION(S) MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE ADHESIVES, SEALERS, AND COATING. ALL MATERIALS USED SHALL NOT EXCEED COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. SFSQUARE FEET PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL. 25 FOR FLAME SPREAD INDEX. UNLESS OTHERWISE REQUIRED BY THE LOCAL SSTSTAINLESS STEEL AUTHORITY FOR ENERGY CODES, THE MINIMUM INSULATION SHALL BE AS SWSANITARY WASTE TESTING FOLLOWS: ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE PIPE SIZE (DIAMETER)INSULATION THICKNESS TELTELEPHONE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING PLUMBING FIXTURES TEMPTEMPORARY CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY LESS THAN OR EQUAL TO 1 1/2" (38MM)1" (24MM) TYPTYPICAL LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL REQUIREMENTS 2" (51MM) OR GREATER1 1/2" (38MM) TMVTEMPERATURE MIXING VALVE AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND WATER HEATER TWTEMPERED HOT WATER 2 APPROVAL. SIZE WATER HEATER PER STARBUCKS STANDARD AND PER AHJ, WHICHEVER (INSULATION VALUE = K VALUE NOT EXCEEDING 0.027 BTU PER INCH/H*FT*F) IS MORE STRINGENT. PROVIDE A GLASS-LINED, ENERGY EFFICIENT, GAS UNOUNLESS NOTED OTHERWISE IDENTIFICATION FIRED (OR ELECTRIC EQUIVALENT) WATER HEATER. PROVIDE INSTALLATION SAFETY COVERS PROVIDE PIPE IDENTIFICATION EVERY 10 FEET (EXCEPT WHERE PIPES ARE COMPLETE WITH FITTINGS AS SHOWN IN THE DRAWINGS. SET HOT WATER INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH INSULATED FOAM LINER EXPOSED TO PUBLIC) IN ACCORDANCE WITH SPECIFICATIONS. VVENT AND TAMPER PROOF STRAP AS FURNISHED BY STARBUCKS AT ALL EXPOSED PIPING. WATER FILTRATION WSANITARY WASTE STARBUCKS WATER FILTRATION VENDOR WILL FURNISH FILTRATION SYSTEM. WHWATER HEATER ICE BIN DRAIN GENERAL CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION WPWEATHER PROOF INSULATE ICE BIN DRAIN LINES WITH 1/2" THICK SELF SEALING SECTIONAL MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR SHALL INSTALL WCOWALL CLEANOUT CLOSED CELL FOAM. FILTRATION SYSTEM. HVAC PIPING CONNECTIONS INSULATE REFRIGERANT SUCTION PIPING AND COOLING COIL CONDENSATE THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO PIPING WITH 3/4" THICK SELF SEALING CLOSED CELL FOAM. INSULATE HVAC HOT EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, AND CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM AND FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND CONDENSATE PIPING WITH 1-1/2" THICK HEAVY DUTY SELF SEALING JACKETED RIGID TUBING. FIBERGLASS. INSTALL THICKER INSULATION WHERE REQUIRED BY CODE. SCHEDULES RAIN CONDUCTORS REFER TO SCHEDULES ON DRAWINGS (PLUMBING & ARCH. SCHEDULES) FOR INSULATE RAIN WATER CONDUCTORS THAT PASS THROUGH OCCUPIED AREAS A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING WITH 1/2" THICK FIBERGLASS. FIXTURES LISTED AS "GC". ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO SUPPLIES. PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY STORE #:8123 PROJECT #:25450-048 CONCEPT: PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL R LEED AP: PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN SHEET TITLE: PLUMBING NOTES SCALE: As Indicated SHEET: P-0001 WASTE & WATER SERVICE CALCULATIONS: NEW EQUIPMENT & PLUMBING FIXTURE SCHEDULE WASTECOLDHOT EQUIPMENT F.U.TOT.F.U.TOT.F.U.TOT. QTY DESIGN IDCOUNTDESCRIPTIONRESP.SERVESWIWVCWCSWFWHWTWCOMMENTS THREE COMPARTMENT SINK1--2.252.252.252.25INDIRECT TO FLOOR SINK DRAIN MOP SINK1222.252.252.252.25 3"-2"----- DRAIN - FLOOR SINK SQUARE - 12IN 305MM 10294 11 SB-GC- HAND SINK2120.510.51 -------- SB-GC DRAIN - GRATE HALF SQUARE - 12IN 305MM 1072611- EMERGENCY FLOOR DRAIN2------ 3"-2"----- GC-GC X01003 FLOOR DRAIN - 6" ROUND RESTROOMS ZURN ZN415B FLOOR DRAIN155---- FAUCET R FLOOR SINK11555---- ---1/2"--1/2"- 10549, 17565 10152 2 FAUCET - DOUBLE LABORATORY WITH BENT RISER SPOUT SB-GC2.2GPM C 2011 STARBUCKS COFFEE COMPANY ICE MACHINE1--0.50.5--INDIRECT TO FLOOR SINK ------- 1/2" 12807, 12808, 18743 101534 FAUCET - WATER TOWER - 12IN 305MM SB-GC KITCHEN SINK6--318318INDIRECT TO FLOOR SINK ---1/2"--1/2"- 12807, 12808, 18743 10215 4 FAUCET - DOUBLE LABORATORY WITH SWING SPOUT SB-GC2.2GPM STARBUCKS COFFEE WATER CLOSET2481020-- ------ 1/2"1/2" 10116, 17809 105973 FAUCET - SINGLE HANDLE SB-GC0.5GPM AERATOR COMPANY URINAL-4-5--- -----1/2"-- 12807, 12808, 18743 10874 4 FAUCET - HOT WATER DISPENSER GOOSENECK SB-GC 2401 UTAH AVENUE SOUTH ------ LAVATORY2121.531.531/2"1/2" 109221 FAUCET - MOP SINK WALL MOUNTED SB-GC10995 SEATTLE, WASHINGTON 98134 ---1/2"---- ESPRESSO MACHINE3--13--INDIRECT TO FLOOR SINK12807, 12808 110033 FAUCET - DIPPERWELL SB-GC0.5GPM METERED (206) 318-1575 ------- 1/2" 17650, 17567 COFFEE BREWER1--11-- 175721FONT - TAP SINGLE HANDLESB-GC THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS WAREWASHER1----66INDIRECT TO FLOOR SINKFILTER THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS -------- 125011 FILTER - RO SYSTEM 600GPD SB-GC-PENTAIR BEVERAGE STATION1--11--INDIRECT TO FLOOR SINK PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED -------- TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE 12507 1 FILTER - RO SYSTEM 40GAL STORAGE TANK SB-GC-PENTAIR KITCHEN SINK1--33--INDIRECT TO FLOOR SINK (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY -------- 128961 FILTER - BRINE TANK SB-GC-PENTAIR TOTAL645532.5 OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. -------- 12899 2 FILTER - POLY GLASS VESSEL SB-GC-PENTAIR -------- 130761 FILTER - PREFILTRATION SYSTEM SB-GC-PENTAIR -------- 13082 1 FILTER - WATER SOFTENER TWIN SB-GC-PENTAIR Design Forum -------- 131491 FILTER - PRESSURE GAUGE SB-GC-PENTAIR Architects Inc. SINK 700 W. Pete Rose Way, Suite 460Donald J. Rethman 2"------ 1 1/2" 101162 SINK - RESTROOM WALL MOUNTED SB-GC10597 Cincinnati, OH 45203Architect In Charge License: Tel: (513) 421-2210 -1 1/2"------ 10549 SINK - RINSE DROP IN SST - 12X20IN 305X510MM SB-GC10152 1 3"-2"----- 109951 SINK - MOP - 24X24IN 610X610MM SB-GC10922 Design Forum -1 1/2"------ 10153, 10874, 10215, 11003 12807 SINK - UTENSIL RINSE WITH GRATE SST - LH - 14X20IN 355X510MM SB-GCELKAY 1 ------- 1 1/2" 10153, 10874, 10215, 11003 128082 SINK - UTENSIL RINSE WITH GRATE SST - RH - 14X20IN 355X510MM SB-GCELKAY Engineering -1 1/2"------ 10152, 17564 17565 SINK - RINSE WITH DRAINBOARD DROP IN - 15X27IN SB-GC 1 700 W. Pete Rose Way, Suite 460Timothy L. Raberding Professional Engineer Cincinnati, OH 45203 -1"----- 1/2" 175691SINK - RINSE 24X8IN WITH INTEGRAL PITCHER RINSERSB-GC-Tel: (513) 421-2210License: -2"------ 17650DRAIN TRAY - 8X5INSB-GC17572 1 ------ 1-1/2"1-1/2" 10874, 10153, 10215 187431PREP STATION SINKSB-GC- TOILET 11/01/17 3"-2"---- X01012 TOILET - TANKLESS EFFICIENT SINGLE FLUSH GC-GCX0102 AMERICAN STANDARD 3461.001 ---1"--- AMERICAN STANDARD 6047.111 (1.1 GPF) X0102 TOILET - FLUSH VALVE MANUAL EFFICIENT GC-GCX0101 2 EQUIPMENT -1/2"------ 17588NITRO STATIONSB-GC- 1 ------ 1/2" 175641PITCHER RINSERSB-GC17565- -1/2"---1/2"- 17567WATER CHILLER - FREDDOSB-GC17572 1 ICE Revision Schedule -3/4"------ 10344 ICE - BIN DROP IN 90LB 40KG SB-GC- 1 RevDateDescription ------- 3/4" 105273 ICE - BIN DROP IN 45LB 20KG SB-GC- -3/4"---1/2"-- 108131 ICE - MACHINE 1391LB REMOTE AIR COOLED SB-GC- -3/4"------ 18029 1 ICE - BIN 854LB SB-GC- CASEWORK 2"-1 1/2"----- 1780910597 1 CABINET WITH HAND SINK SB-GC RELOCATED EQUIPMENT & PLUMBING FIXTURE SCHEDULE DESIGN IDCOUNTDESCRIPTIONRESP.SERVESWIWVCWCSWFWHWTWCOMMENTS FAUCET ------1/2"- F2 (R)S2 (R) FAUCET - PRE RINSE SPRAYER WALL MOUNTED GC1.2GPM 1 ------ F3 (R)S2 (R)1/2"1/2" 1 FAUCET - PRE RINSE SWING SPOUT GC1.2GPM ---1/2"---1/2" F1 (R)S1 (R) FAUCET - HAND SINK WALL MOUNTED GC0.5GPM AERATOR 1 OTHER ----3/4"-3/4"- WH (R) WATER HEATER 50GAL 190L ELECTRIC GC- 1 SINK 2"-1 1/2"----- S1 (R)F1 (R) SINK - HAND WALL MOUNTED SST GC 1 -2"------ S2 (R)F2 (R), F3 (R) 1 SINK - 3 COMP WORK SST - 93IN 2350MM GCELKAY EQUIPMENT ------- B (R)1/2" 1 BREWER DUAL SOFT HEAT GC- -1 1/4"----1/2"- DS (R) DISHWASHER SANITIZER GC- 1 ------- E (R)1/2" 3 ESPRESSO MACHINE MASTRENA GC- PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY STORE #:8123 PROJECT #:25450-048 CONCEPT: PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL R LEED AP: PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN SHEET TITLE: PLUMBING SCHEDULES SCALE: As Indicated SHEET: P-0002 GENERAL NOTES: A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL 3/4"3/4"3/4"3/4"3/4" 3/4" FWFW FULL SCOPE OF WORK. HWHWHWHW 1/2" 1"3/4"3/4"3/4"3/4"3/4" TW 1/2"1/2"1/2"TW TW CW 1"1-1/2"1-1/2"CW 1-1/2"1"1"1"1"1/2" C.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. CWCW 3/4" D.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. CW CW R 19 CBL CSW E.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. LINE OF FINISHED CEILING C 2011 STARBUCKS COFFEE COMPANY F.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. STARBUCKS COFFEE 1/2"1/2" G.CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER 10 DAYS (MINIMUM) BEFORE THE TIME THAT THE COMPANY 1/2" 1/2" FILTER SYSTEM IS TO BE STARTED UP. 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 KEYED NOTES: (206) 318-1575 WH(R) THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS 3/4" CW 1.PIPE 3/4" SOFT WATER TO WATER HEATER AND 3/4" SOFT WATER TO MIXING VALVE. PIPE 1" THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 23 1/2" HW REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR HOT WATER AND 1/2" TEMPERED WATER FROM RELOCATED WATER HEATER. WATER WATER FILTRATION EQUIP USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS 3/4" FW PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS HEATER AS SPECIFIED ON SHEET P0002. REFER TO WATER HEATER DETAIL ON SHEET P5001. TOP OF FLOOR SLAB CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT 2.1/2" HOT WATER AND 1/2" COLD WATER TO FAUCET WITH INTEGRAL ASSE 1001 ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY 16 ATMOSPHERIC VACUUM BREAKER AT MOP SINK. CAULK AND SEAL BACK OF SINK TO WALL.OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. 3.3/4" CITY COLD WATER WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT TO FILTRATION EQUIPMENT WITH 3/4" FILTERED WATER OUT. PLUMBING CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ACTIVATION PROCEDURES Design Forum FOR BOTH SYSTEMS. REFER TO FILTER CONNECTION DETAIL ON SHEET P5001. DOMESTIC WATER SINGLE LINE SCHEMATIC 4.1/2" HOT WATER AND 1/2" COLD WATER TO RELOCATED FAUCET AND RELOCATED SPRAY AT Architects Inc. RELOCATED THREE COMPARTMENT SINK. CAULK AND SEAL BACK OF SINK TO WALL. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge License: Tel: (513) 421-2210 5.1/2 " HOT WATER TO RELOCATED DISHWASHER. INSTALL SHUT-OFF WITH 3/4" MALE HOSE-END FITTING @ 18" AFF UNDER COMPARTMENT SINK. SHUT-OFF TO INCLUDE PRESSURE REDUCING VALVE, PRESSURE GAUGE (SET @ 20 PSIG, * OR - 5 PSIG), LINE STRAINER, AND SHOCK ARRESTOR IN WALL. CONNECT RELOCATED SANITIZER TO HW Design Forum SUPPLY WITH 72" LONG BRAIDED STAINLESS STEEL HOSE. 7 10597 Engineering 6.1/2" FILTERED WATER TO ICE MACHINE WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT. REDUCE TO 3/8" AT MACHINE. 700 W. Pete Rose Way, Suite 460Timothy L. Raberding Professional Engineer Cincinnati, OH 45203 Tel: (513) 421-2210License: MEN'S 7.1/2" TEMPERED WATER AND COLD WATER TO FAUCET AT SINK. RESTROOM X0102 13 8.1/2" FILTERED WATER TO RELOCATED COFFEE/TEA BREWER WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT. INSTALL SHUT-OFF IN CABINET @ 24" AFF REDUCE TO 3/8" AT UNIT.11/01/17 9.1/2" FILTERED WATER TO RELOCATED ESPRESSO MACHINE PUMP. CONNECT 3/8" COMPRESSION BRAIDED STAINLESS STEEL HOSE FROM SHUT-OFF TO RELOCATED ESPRESSO MACHINE WATER INLET. SEE DETAIL PROVIDED ON SHEET P5001. 10.1/2" COLD WATER TO DIPPERWELL FAUCET. REDUCE TO 1/4" AT UNIT. HALLWAY 11.1/2" FILTERED WATER TO INSTAHOT TAP. REDUCE TO 1/4" AT UNIT. 12.1/2" FILTERED TO WATER TOWER FAUCET LOCATED IN WATER STATION. X0102 13 13.1" COLD WATER TO TOILET. PROVIDE WATER HAMMER ARRESTOR IN SUPPLY LINE. SEE Revision Schedule SHEET P5001. RevDateDescription 14.3/4" FILTERED WATER, 3/4" COLD WATER AND 1/2" HOT WATER DOWN IN WALL TO BELOW COUNTERTOP LEVEL. VERIFY ROUTING IN FIELD WITH GC PRIOR TO INSTALLATION. 19 WOMEN'S 15.1/2" HOT WATER WITH APOLLO VALVES MODEL DCAP ASSE 1012 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT AND 1/2" COLD WATER WITH ASSE 1022 DOUBLE CHECK VALVE WITH CAFE/SEATING RESTROOM ATMOSPHERIC VENT TO SINK. 10597 7 16.CONNECT TO EXISTING DOMESTIC WATER SERVICE TO LEASE SPACE. VERIFY EXACT SIZE, LOCATION, PRESSURE BACK FLOW PREVENTION AND REQUIREMENTS ON SITE. 16 17.1/2" COLD WATER WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT TO 23 PITCHER RINSE WITH INLINE DCV BACKFLOW PREVENTER. WORKROOM CW 18.ROUTE 3/4" FILTERED WATER, 3/4" COLD WATER, AND 1/2" HOT WATER THROUGH CABINETRY. CONNECT TO ITEMS 10153 (2), 10215 (2), 10874 (2), 11003 (2) AND E (R) (2). REFER TO NOTES 9, 10, 11, 12, AND 15. VERIFY ROUTING IN FIELD WITH GC PRIOR TO INSTALLATION. 1212 1015310153 1111 19.1/2" COLD WATER TO TRAP PRIMER. SEE DETAIL P-5001. 1087410874 1515 1021510215 20.1/2" COLD CARBONATED BEVERAGE LINE FROM WATER CHILLER WITH 2-1/2" INSULATION. 9 E(R) COORDINATE ROUTING WITH GC AND STARBUCKS CM. SEE MANUFACTURERS INSTALLATION 1010 1100311003 INSTRUCTIONS. 21.1/2" FILTERED WATER WITH ASSE 1022 DOUBLE CHECK VALVE WITH ATMOSPHERIC VENT TO 10813 6 WATER CHILLER. 22.1/2" TEMPERED WATER AND COLD WATER TO RELOCATED FAUCET AT RELOCATED SINK. 23.EXISTING WATER METER AND BACKFLOW PREVENTER TO REMAIN WITHOUT MODIFICATION. BEVERAGE PREP. FWFW TW TW CWCW HW HW 15 15 17564 10152 PROJECT NAME:PROJECT ADDRESS: 17 CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY 10152 F1 (R)22 18 STORE #:8123 14 PROJECT #:25450-048 CONCEPT: 12 7 10597 10153 11 10874 PALETTE: E(R) 9 17 17569 15 10215 F2 (R)11/1/17 ISSUE DATE: 8 B(R) 20 17572 4 F3 (R) CW PROGRAM MANAGER:KIRBY MEINDL WH(R) 1 10153 CSW 11 17567 21 R 10874 5 DS(R) 12 LEED AP: WORKROOM PRODUCTION DESIGNER:PETER CHEETHAM 10922 2 CHECKED BY:DON RETHMAN SHEET TITLE: 10 10215 15 11003 1250112507 PLUMBING SUPPLY PLAN 1307613149 3 12896 12899 13082 SCALE: As Indicated 02'4'8' N DOMESTIC WATER PLAN SHEET: 1 Scale: 1/4" = 1'-0" SCALE: " = 1' -0" 4 P-1101 GENERAL NOTES: A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B.FOR FULL SCHEDULES AND COMPLETE LISTING SEE ARCHITECTURAL SCHEDULES. CONFIRM ALL QUANTITIES WITH PLAN. C.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. R D.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. C 2011 STARBUCKS COFFEE COMPANY E.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. STARBUCKS COFFEE F.ALL INDIRECT DRAIN LINES SHALL BE ROUTED WITHOUT DIPS OR SAGS TO TERMINATE WITH AN AIR GAP INTO AN APPROVED INDIRECT WASTE RECEPTOR. COMPANY 10116 12 2401 UTAH AVENUE SOUTH G.REFER TO DETAILS FOR FURTHER REQUIREMENTS. SEATTLE, WASHINGTON 98134 (206) 318-1575 MEN'S H.LOCATIONS OF EXISTING PIPING AND FIXTURES ARE APPROXIMATE. VERIFY LOCATION IN 25 FIELD. RESTROOM THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL X0100 16 REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 20 X0101 19 REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED SAN TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY 20 OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) KEYED NOTES: UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. 23 1.3/4" PRESSURE RELIEF FROM RELOCATED WATER HEATER TO MOP SINK. Design Forum HALLWAY 2.1" INDIRECT DRAIN FROM RELOCATED WATER HEATER DRIP PAN TO MOP SINK. 24 3.3" WASTE FROM MOP SINK. Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge 4.2" INDIRECT DRAIN FROM RELOCATED THREE COMPARTMENT SINK TO FLOOR SINK. License: Tel: (513) 421-2210 VERIFY LOCATION IN FIELD AND REQUIREMENTS PRIOR TO INSTALLATION. 20 5.1-1/4" INDIRECT DRAIN FROM RELOCATED DISHWASHER TO FUNNEL OVER FLOOR SINK IF PERMITTED. SAN Design Forum X0101 19 6.3/4" I.D. F.P.T. FROM DRAIN ON ICE MACHINE TO INDIRECT DRAIN AT FLOOR SINK. 23 Engineering 20 X0100 16 CAFE/SEATING 700 W. Pete Rose Way, Suite 460Timothy L. Raberding 25 7.5/8" DRAIN HOSE TO INDIRECT DRAIN RISER. SEE DETAIL ON SHEET P5001. WOMEN'S Professional Engineer Cincinnati, OH 45203 Tel: (513) 421-2210License: RESTROOM 8.1" INDIRECT INSULATED DRAIN LINE FROM ICE BIN DROP TO FLOOR SINK. 9.1-1/2" INDIRECT DRAIN FROM SINK TO FLOOR SINK. 10116 12 11/01/17 10.3/4" INDIRECT DRAIN FROM WATER STATION DRAIN BOARD TO FLOOR SINK. 11.3" WASTE FROM FLOOR SINK. 12.2" WASTE FROM SINK. 13.FLOOR CLEAN OUT MATCH TO DRAIN LINE SIZE. 23 14 14 14.1-1/2" INDIRECT DRAIN TO FLOOR SINK. IF INDIRECT NOT ALLOWED, PROVIDE 2" 1280712808 1010 E (R)7 DIRECT DRAIN. 10527 8 15.3/4" INDIRECT DRAIN FROM WATER EQUIPMENT TO MOP SINK. 6 10813 Revision Schedule 8 18029 16.3" WASTE FROM FLOOR DRAIN. RevDateDescription 10294 11 10527 107268 17.1" INDIRECT DRAIN FROM PITCHER RINSER SINK TO FLOOR SINK. 28 18.2" WASTE FROM RELOCATED SINK. 1029410294 23 13 BEVERAGE 1111 2417588 26 1072610726 PREP. 19.3" WASTE FROM WATER CLOSET. GWGWGW 13 10294 10294 20.WALL CLEANOUT TO MATCH DRAIN SIZE. 11 11 10294 10726 10726 11 10549 14 10726 17569 917 17565 21.PROVIDE SCHIER GB-250-4P-C24-HP-SR24 100GPM 1,076LBS. CAPACITY GREASE INTERCEPTOR WITH 4" INLET AND OUTLET, H20 HIGHWAY RATED PICKABLE CAST 17650 22 10344 8 IRON COVER, AND 24" 24 SERIES SHORT RISER. S1 (R) 18 28 28 28 22.2" INDIRECT DRAIN FROM DRAIN TRAY. 23.CONNECT TO EXISTING SANITARY BUILDING DRAIN. 23 17809 12 10294 24.CONNECT TO EXISTING 4" VENT THROUGH ROOF. 11 WORKROOM E (R) 7 10726 25.1/2" CW FROM TRAP PRIMER TO FLOOR DRAIN TRAP. SEE SHEET P-1101 FOR 12808 10 9 18743 417567 S2 (R) 27 LOCATION. SEE DETAIL, SHEET P-5001. 14 10294 11 10294 DS (R) 5 10726 11 10726 26.1/2" INDIRECT DRAIN FROM NITRO STATION TO FLOOR SINK. 28 X0100 15 16 2 SAN WH (R) 1 10294 27.1/2" INDIRECT DRAIN FROM WATER CHILLER TO FLOOR DRAIN. 11 10726 28.2" VENT PIPE. 23 29.EXISTING CLEANOUT AT GRADE TO REMAIN WITHOUT MODIFICATION. 105278 10995 3 30.CLEANOUT AT GRADE TO MATCH DRAIN LINE SIZE. 29 PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY 21 3030 STORE #:8123 23 PROJECT #:25450-048 CONCEPT: PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL R LEED AP: PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN SHEET TITLE: PLUMBING WASTE PLAN SCALE: As Indicated SHEET: PLUMBING WASTE PLAN 02'4'8' SCALE = 1/4" = 1' - 0" N P-1102 Scale: 1/4" = 1'-0" 11/01/17 GENERAL NOTES: PIPING SUPPORT SPACING (MAXIMUM) GAS PIPE SIZING CHART A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. PIPE DIAMETER (IN)SUPPORT SPACING (FT) < 2psi INLET PRESURE B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF 1/2"6'-0" PRESSURE DROP 0.5" W.C. WORK TO REVEAL FULL SCOPE OF WORK. 3/4" OR 1" 8'-0" SPECIFIC GRAVITY C.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL 0.6000 PLUMBING EQUIPMENT. 1-1/4" OR LARGER 10'-0" PIPE SIZE R D.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. C 2011 STARBUCKS COFFEE COMPANY 1"2" NOMINAL1/2"3/4"1-1/4"1-1/2" LENGTH STARBUCKS COFFEE (FEET)CAPACITY (CFH) COMPANY 2401 UTAH AVENUE SOUTH 10360678139020904020 172 SEATTLE, WASHINGTON 98134 (206) 318-1575 2011846695714302760 247 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL GAS EQUIPMENT REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS KEYED NOTES: THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 309519937476811502220 REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR CAPACITY (MBH) MARKDESCRIPTION USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED 40811703206579851900 1.1-1/4" GAS LINE UP EXTERIOR WALL TO ROOF WITH 6" DRIP LEG AT BASE. PROVIDE TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE RTU-1(E)RTU 115 (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT SUPPORTS AT TOP AND BASE OF PIPING TO ALLOW FREE EXPANSION AND CONTRACTION ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OF PIPING. GAS PIPING SIZED TO DELIVER 345 CFH WITH A PRESSURE OF 7.5" WC, MAX. 501512845838731680 72 OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) RTU-2(E)RTU UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. PRESSURE LOSS OF 0.5" WC., SPECIFIC GRAVITY OF 0.6, AND TOTAL DEVELOPED LENGTH 115 OF 90 FEET. 60651372575287911520 RTU-3RTU 115 2.EXISTING 6" DIRT LEG, GAS COCK, AND UNIONS AT CONNECTION TO RTU TO REMAIN. 70601262374867281400 CONNECT NEW GAS PIPING TO EXISTING GAS PIPE AT RTU. Design Forum 80562204526771300 117 3.NEW GAS METER BY GAS UTILITY PROVIDER. Architects Inc. 700 W. Pete Rose Way, Suite 460Donald J. Rethman 4.PROVIDE 6" DIRT LEG, GAS COCK, AND UNIONS AT CONNECTION TO RTU. 90521102076351220 424 Cincinnati, OH 45203Architect In Charge License: Tel: (513) 421-2210 TOTAL LOAD345 5.ROUTE GAS PIPING ALONG ROOF TO RTUs. SEE CHART THIS PAGE FOR SUPPORT 100501041954006001160 SPACING. SUPPORTS SHALL ALLOW FREE EXPANSION AND CONTRACTION OF PIPING. TOTAL DEVELOPED PIPE LENGTH: 90 FEET Design Forum 125921733555321020 44 Engineering 1504083157322482928 700 W. Pete Rose Way, Suite 460Timothy L. Raberding Professional Engineer Cincinnati, OH 45203 Tel: (513) 421-2210License: 11/01/17 RTU-3 4 Revision Schedule RevDateDescription 5 RTU-1 (E) RTU-2 (E) 2 1-1/4" GAS 230 CFH 1" GAS 115 CFH PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 2 131ST & HAZEL DELL 13170 HAZEL DELL PKWY 5 STORE #:8123 PROJECT #:25450-048 CONCEPT: PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL R LEED AP: 3 5 PRODUCTION DESIGNER:PETER CHEETHAM 1-1/4" GAS 345 CFH CHECKED BY:DON RETHMAN 1 SHEET TITLE: GAS PIPING PLAN SCALE: As Indicated 02'4'8' N GAS PIPING PLAN SHEET: 1 SCALE: " = 1' -0" Scale: 1/4" = 1'-0" 4 P-1104 THERMOMETER (TYP.) PROVIDE CLEANOUT WITH ADJUSTABLE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). CLEAN THE TOP OF DOMESTIC COLD EXPOSED FCO AFTER INSTALLATION.FLOOR SINK WITH HALF GRATE SET WATER (SOFT) FLUSH WITH TOP FIN. FLR. WATER (TW) CLEANOUT PLUG AS SPECIFIED. APPLY TEFLON JOINT COMPOUND TO THE CAULK JOINT CLEANOUT PLUG THREADS ASSE 1070 THIN SET CERAMIC TILE, TYP. MIXING VALVE SHUT-OFF VALVE FLOOR SLAB ON GRADE (TYP.) SAME SIZE AS SEWER UP TO 4" MAXIMUM MEMBRANE CLAMP R CHECK VALVE (TYP.) CONCRETE INFILL AT TRENCH FOR AS REQUIRED FOR LONG SWEEP ELBOW AT BELOW GRADE UTILITIES C 2011 STARBUCKS COFFEE COMPANY DEPTH OF SEWER END OR TURN OF RUN WATTS DET-5 12" HIGH x 6" WIDE EXPANSION TANK SANITARY AND/OR COMBINATION WYE AND EIGHTH HEAT TRAP (TYP.) STORM SEWER, SIZE STARBUCKS COFFEE BEND IN RUN, REDUCING TYPE IF UNION (TYP.) PER PLAN REQUIRED. ENTER TOP OF PIPE. GRAVEL BACKFILL COMPANY DIRECTION OF FLOW 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 NO-HUB CONNECTION T AND P REFER TO SPECIFICATIONS FOR MORE INFORMATION. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, RELIEF (206) 318-1575 WATER VALVE SHOWN ON PLANS AND RISERS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL HEATER 3" WASTE DRAIN REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS CLEANOUT WHERE THERE IS 18" CLEAR AROUND, FOR ACCESSIBILITY. CONSULT LOCAL CODES AND THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE (RELOCATED) OFFICIALS FOR OTHER REQUIREMENTS. REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS TO MOP SINK PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS FLOOR SINK DETAIL CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED 3 TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE N.T.S. FLOOR CLEANOUT (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT 2 ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY N.T.S. OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) 3/4" HOSE UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. END VALVE PLATFORM ESPRESSO MACHINE DETAIL NOTES: BRAIDED STAINLESS STEEL HOSE. BY G.C. 5/8" WIRE REINFORCED DRAIN HOSE 9/16-24 UNEF COMPRESSION Design Forum 1.THIS DETAIL IS SCHEMATIC ONLY. FOR THE TO INDIRECT PIPE RISER (TYP. 2) CONNETION 150 PSIG MIN. RATING PACKAGED LOCATION OF THE COMPONENTS SHOWN, AND 1" DRAIN TO (TYP. 2) CONTROLS ESPRESSO MACHINEESPRESSO MACHINE 6" HIGH Architects Inc. EXTENT OF THE WORK REQUIRED, SEE THE PLAN MOP SINK 1-1/2" ABS DWV INDIRECT WASTE PIPE DRAIN PAN 700 W. Pete Rose Way, Suite 460Donald J. Rethman DRAWINGS. TO FLOOR SINK SLOPE HORIZONTAL Cincinnati, OH 45203Architect In Charge COUNTER TOP License: Tel: (513) 421-2210 ASSE 1022 DOUBLE CHECK VALVE AT 1/4" PER FOOT. (TYP. 2) 2.ALL WATER HOSE SHALL BE THE MINIMUM LENGTH WITH ATMOSPHERIC VENT (TYP. 2) ELECTRIC WATER HEATER NEEDED AND SUPPORTED AS REQUIRED TO AVOID 1 N.T.S. STRESSING CONNECTIONS AND COILING HOLD PIPING TIGHT TO BACK WALL WATER PUMP. INSTALL TO ALLOW HOT WATER HEATER NOTES: Design Forum EXCESSIVE HOSE. ROUTE TO AVOID KINKING AND (TYP. ) ACCESS TO INTEGRAL PUMP FILTER. 1. MIXING VALVE SHALL BE EQUAL TO LEONARD MODEL 370-LF. ALLOW SPACE FOR UNDER COUNTER SEE PUMP ATTACHEMENT DETAIL REFRIGERATOR AND ACCESS TO EQUIPMENT AND (TYP. 2) Engineering VALVES. BRAIDED STAINLESS STEEL HOSE.700 W. Pete Rose Way, Suite 460Timothy L. Raberding Professional Engineer Cincinnati, OH 45203 9/16-24 UNEF COMPRESSION PUMPPUMP Tel: (513) 421-2210License: 3.ALL PIPING SHALL BE HELD TIGHT TO WALLS CONNETION 150 PSIG MIN. RATING SLOPED WHERE REQUIRED AND ROUTED TO 3/4" BALL VALVE. (TYP. 2) ALLOW ACCESS TO EQUIPMENT AND VALVES. INDIRECT WASTE LINE 3/4" FILTERED WATER STUB-UP FROM FROM FIXT REF PLAN 1/2" NPT TO HOSE COMPRESSION BELOW FLOOR. 3/4"3/4" 4.ROUTE HORIZONTAL PIPING A MINIMUM OF 6" 11/01/17 CONNECTION (TYP. 2) ABOVE FLOOR. FWFW 1/2" BALL VALVE. (TYP. 2) 5.INSTALL PUMP AS SHOWN ON PLANS. SET SCREW FW COORDINATE LOCATION AND ELEVATION WITH NO-HUB OUTLET AIR BREAKER. SIZE FLOOROTHER TRADES. ORIENT PUMP AS REQUIRED TO VARIES ACCORDING TO WASTE LINE ALLOW MAINTENANCE. FLOOR SIZE SINK AIR GAP PER CODE. MINIMUM 1" AIR GAP =2 x DIA NO-HUB CONNECTION OR SPIGOT OF INLET MIN. OUTLET AS ALLOWED Revision Schedule ESPRESSO MACHINE GENERAL PIPING CONNECTION SCHEMATIC WASTE LINE TO RISER OR GREASE RevDateDescription 4 INTERCEPTOR AS REQUIRED N.T.S. EXPANSION TANK TO DISHWASHER, BAR SINKS,BRASS CHECK VALVE MOP SINK, COMPARTMENT SINK, ETC. AIR BREAKER DETAIL 1" (25mm) HOT WATER OUTLET 5 N.T.S. TEMPERED HOT WATER TO HAND SINKS 1" (25mm) WATER HAMMER ARRESTOR TEMPERATURE MIXING VALVE UNION (TYP.) SIZING CHART HOT WATER TANK (SEERO STORAGE TANK FIXTURE UNIT CONNECTION TO SPECIFICATIONS & HOT WATER PDI SIZE RATINGSUPPLY LINE TANK DETAIL FOR FURTHER INSTALLATION REQUIREMENTS) 3/4" 1-11A 1/2" (15mm) CHROME ESCUTCHEONS (TYP.) 1" (25mm) BYPASS 12-32B1" CONCEALED COPPER PIPING (TYP.) BRASS THREADED BALL SHUT-OFF 1/2" (15mm) CONNECT 1/2" PIPE (WITHOUT SHUT-OFF COLD WATER MAIN BOOSTER PUMP AND GFCI 120V VALVE (TYP.) MAX 72" (1829mm) AFF 1'-2 3/4"9 1/4" 11" 1/2" (15mm) FIP VALVE IN BRANCH) TO TRAP PRIMER33-60C1" RECEPTACLE IF REQUIRED BRANCH PIPE WITH SHUT-OFF POINT OF USE FILTER LOCATED VALVE OFF TOP OF BRANCH PIPE. 3/4" (20mm) 1" (25mm)AT ICE MACHINE VALVE FEEDING PLUMBING INSULATE PIPE UPSTREAM OF TRAP 1 1/4"1/2" (15mm) 61-113D FIXTURE(S) UNION (TYP.) EMERGENCY BY-PASS PRIMER, BUT NOT DOWN STREAM. 1/2" (15mm) PRECISION PLUMBING PRODUCTS GFCI 120V QUAD RECEPTACLE FOR FILTER 1 1/2" 114-154E PR-500 OR EQUIVALENT ASSE 1018 SYSTEM 78" (1981mm) AFF (NOTE 3)TO ICE MACHINE AUTOMATIC TRAP PRIMER VALVE OUT PEX PIPING TYP. (SEE NOTE 2)TO FILTERED FIXTURES (ESPRESSOS, WITH INTEGRAL AIRGAP. INSTALL 155-330F 2" BREWERS, HOT TAP, WATER TOWER, ETC.) INSTALL TRAP PRIMER LINE(S) DOWNSTREAM TRAP PRIMER MINIMUM 12" ABOVE OF TRAP PRIMER OR DISTRIBUTION UNIT USING CITY WATER IN FLOOR FOR EVERY 20' OF PRIMER 1/2" (15mm) FIP (FEMALE INTERNATIONAL 1/2" SOFT COPPER TUBING. INSTALL WITHOUT 1" (25mm) REFERENCE PDI-WH-201. DISCHARGE PIPE. PIPE THREAD FITTING)(TYP.2) KINKS,AND SLOPE CONTINUOUSLY TOWARDS TO NON FILTERED FIXTURES RO CONTROL SYSTEM (NOTE 5) FLOOR DRAIN. PROVIDE DISTRIBUTION UNIT(S) IN PROJECT NAME:PROJECT ADDRESS: (TOILETS, HAND SINKS, DIPPER CARMEL, IN 46033 131ST & HAZEL DELL ININOUT 13170 HAZEL DELL PKWY PRE-FILTER WHERE MORE THAN ONE TRAP IS WELLS, HOSE BIBBS, ETC.) SERVED BY ONE TRAP PRIMER 2 1/2" (65mm) CLEARANCEGFCI 120V RECEPTACLE FOR FILTER STORE #:8123 VALVE. RUNOUTS TO LAST FIXTURE SHALL REQUIRED FOR FILTER REMOVALSYSTEM 54" (1372mm) AFF(NOTE 3) TO H.W. & C.W.WATER HAMMER CONCEAL PIPE(S) IN PARTITION OR CHASE NOT BE SMALLER THAN SIZE REQUIRED ARRESTORS SUPPLY 3/4" (20mm) IN FINISHED AREAS. TRAP PRIMER AND PROJECT #:25450-048 FOR ARRESTORS PIPES MAY BE INSTALLED EXPOSED IN IF TRAP PRIMER IS INSTALLED 3/4" (20mm) FIP (TYP.2 TO SOFTENER) CONCEPT: ABOVE HARD CEILING, PROVIDEUNFINISHED, NON-PUBLIC AREAS. 75" (1905mm) AFF WATER SOFTENER HEAD AND TANKS (BACK) ACCESS DOOR PER SPECIFICATIONS. 69" (1752mm) AFF PALETTE: BRINE TANK (FRONT) 60" (1524mm) AFF 11/1/17 ISSUE DATE: PROVIDE WATER SOFTENER DRAIN INSTALLED PER CODE (NOTE 4) IF PIPE IS BELOW FLOOR SLAB ON PROVIDE FLOOR DRAIN BODY OR PROGRAM MANAGER:KIRBY MEINDL 18"Wx24"Dx6"H (455mmWx610mmDx150mmH) GRADE, PROVIDE 1/2" ELASTOMERIC MOP SINK P-TRAP WITH THREADED TRAP R RACK PROVIDED WITH UNIT INSULATION FROM PRIMER CONNECTION LEED AP: PRIMER CONNECTION. PROVIDE TO 1" ABOVE FLOOR SLAB. SWEAT TO THREADED ADAPTER. PRODUCTION DESIGNER:PETER CHEETHAM NOTES: BRAZE JOINT BELOW FLOOR SLAB 1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR. CHECKED BY:DON RETHMAN ON GRADE. 2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS WHERE ALLOWED BY CODE. 3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES. TO FIXTURESTO FIXTURES PIPING TO LAST PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE REQUIRED BY LOCAL AUTHORITIES.PIPING 4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SHEET TITLE: FIXTURE SPECIFICATIONS). ARRANGEMENT SHOWN IS SCHEMATIC:ADJUSTTO SUIT FIELD CONDITIONS.REFER TO SPECIFICATIONS AND 5. PROVIDE RO INDIRECT DRAIN TO SINK INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH RO EQUIPMENT CUTSHEET IN ITEM SPECIFICATIONS). PLUMBING FIXTURE SCHEDULE FOR MORE INFORMATION.INSTALL TRAP PRIMER VALVE AND DISTRIBUTION UNIT PLUMBING DETAILS 6. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER PER MANUFACTURER'S RECOMMENDATIONS. EXCHANGE TANK SCHEMATIC. 7. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER. SCALE: As Indicated SHEET: WATER HAMMER ARRESTOR TRAP PRIMER DETAILTYPE 3 WATER TREATMENT SYSTEM 7 68 N.T.S. N.T.S.N.T.S. P-5001 MECHANICAL SPECIFICATION CONTINUED CONTINUED ABBREVIATIONS GENERAL GRILLES, REGISTERS, AND DIFFUSERS: AFFABOVE FINISHED FLOOR REMOTE CONDENSING UNITS: SCOPE: GRILLES, REGISTERS, AND DIFFUSERS SHALL BE AS SPECIFIED AND SHALL BE AHJAUTHORITIES HAVING JURISDICTION CONTRACTOR SHALL SET AND INSTALL REMOTE CONDENSING UNITS ON ROOF FOR ICE MACHINE. SET UNIT ON A PAIR OF PRE-FABRICATED ROOF RAILS. THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A MECHANICAL CONTRACTOR SUPPLIED, UNLESS OTHERWISE NOTED. DIFFUSERS APPROXAPPROXIMATE ANCHOR CONDENSING UNIT TO RAILS WITH GALVANIZED STRAPPING OR AIRCRAFT CABLE. CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE PIPING FROM REMOTE CONDENSING UNIT TO ICE MACHINE EVAPORATOR UNIT. SIZE PIPING AND PROVIDE INSTALLATION DETAILS AS REQUIRED BY SHALL FURNISH ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS BLDGBUILDING MANUFACTURER. INSTALL THE ENTIRE REFRIGERANT SUCTION LINE WITH 1/2" ARMAFLEX. PROVIDE WHITE UV COATING ON ALL EXTERIOR INSULATION. MECHANICAL WORK. NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF USE MANUFACTURER'S ADHESIVE TO SEAL ALL SEAMS AND JOINTS. MITER ALL ELBOWS - DO NOT BEND INSULATION AROUND FITTINGS. CEILING AND WALLS USED IN THIS PROJECT. CLGCEILING SITE EXAMINATION: CONSTCONSTRUCTION THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, THERMAL INSULATION: CDCEILING DIFFUSER DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER CO2CARBON DIOXIDE OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE R CXACOMMISSIONING AGENT REQUIREMENTS OR ASHRAE 90.1-2004, WHICHEVER IS MORE STRINGENT. STANDARDS: C 2011 STARBUCKS COFFEE COMPANY PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON DEGDEGREES EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE PROVISIONS OF CSA, CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT DTLDETAIL ULC, ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH DMSTARBUCKS DESIGN MANAGEREXTERNALLY INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK ICE MACHINE REMOTE CONDENSER SCHEDULE INDIVIDUAL UNIT OR ASSEMBLY. DNDOWN THAT ARE INTERNALLY LINED WITH CODE REQUIRED THICKNESS. THERMAL STARBUCKS COFFEE DWG(S)DRAWING(S) INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND DIMENSIONS CODES: WEIGHT SMOKE DEVELOPED NO GREATER THEN 50. INTERNALLY INSULATE EXTERIOR COMPANY FLAMOCPREMARKS DID NO.REFRIGERANTVOLT/PHMANUFACTURERMODEL NUMBER ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL EAEACH DUCTWORK PER CODE. WIDTHDEPTHHEIGHTLBS. 2401 UTAH AVENUE SOUTH AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND ECELECTRICAL CONTRACTOR SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. SEATTLE, WASHINGTON 98134 ELECELECTRICAL ACOUSTICAL DUCT LINER: 10813R-404A29.5"29.18"39"208/1--126ICE-O-MATICVRC-2661B1, 2 THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM EMEMERGENCY UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" (25MM) GLASS (206) 318-1575 STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. NOTES: (E) OR (EX)EXISTING FIBER ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL EXTEXTERIOR WITHIN 10'-0" (305CM) OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS PERMITS AND FEES: EGEXHAUST GRILLE 1.PROVIDE 40 FOOT PRECHARGED TUBING KIT. INCREASE DUCT SIZE INDICATED ON PLANS AS NEEDED TO ACCOMMODATE THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR LINER. LINER SHALL BE FASTENED TO DUCT WITH MECHANICAL LINER 2.SECURE UNIT TO ROOF SUPPORTS WITH CODE-APPROVED CABLING OR STRAPS. USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. F&IFURNISH & INSTALL FASTENERS IN ACCORDANCE WITH SMACNA.PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED FLRFLOOR TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE WARRANTY: FTFOOT/FEET (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT FLEXIBLE DUCTWORK: THE MECHANICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS SHOWN IN PLAN AND OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ROOFTOP AC UNIT SCHEDULE (PROVIDED BY CONTRACTOR UON) GGAS PIPING UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. NOT ABOVE HARD LID CEILINGS. FLEXIBLE DUCTWORK SHALL NOT FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK GCGENERAL CONTRACTOR TOTALSENSIBLEGAS HEAT,GAS HEAT,ENTERING AIR CONDITIONS PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE SUPPLYEXT. S.P.,FAN TAUT AND APPROPRIATELY FASTENED TO RIGID BRANCH DUCT & DIFFUSER. COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. COOLINGCOOLINGINPUTOUTPUT MCAMOCPE.E.R.REMARKS UNIT NO.O.A. CFMVOLT/PHMANUFACTURERMODEL NUMBER HRHOUR BENDS SHALL BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND. BHP CFMAMBIENT" W.C. (TONS)(MBH)(MBH) (MBH) HVACHEATING, VENTILATION, AIR CONDITIONING SUPPORT BANDS SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT. LEED: Design Forum RTU-1 (EXISTING) 2,400658.11159380679512.24208/3365011.0CARRIER48TCEA07A2A5A0A0A05,6 FLEXIBLE DUCTWORK SHALL BE UL 181 LISTED AS A CLASS 1 AIR DUCT. 140 ALL WORK, MATERIALS AND EQUIPMENT SHALL MEET LEED REQUIREMENTS & CODE. IN CASE OF I.D.INSIDE DIMENSION CONFLICT, THE HIGHER STANDARD SHALL APPLY. RTU-2 (EXISTING) 2,400510657.61159280679512.14208/332.4409.0CARRIER48TFE007 - - - 511 - -5,6 DAMPER AIR LEAKAGE: Architects Inc. LLLANDLORD MOTORIZED AND NON-MOTORIZED DAMPERS USED FOR OUTSIDE AIR INTAKES, RTU-3 (NEW)Donald J. Rethman 48TCEA07A2A5A0A0A0 700 W. Pete Rose Way, Suite 460 2,400690658.11159380679512.24208/332.44011.0CARRIER1,2,3,4,5,6,7,8 LVLOW VOLTAGE EXHAUST & RETURN OUTLETS (INCLUDING THOSE WITHIN HVAC EQUIPMENT) Cincinnati, OH 45203Architect In Charge HVAC EQUIPMENT AND MATERIALS License: Tel: (513) 421-2210 SHALL HAVE A MAXIMUM AIR LEAKAGE VALUE PER THE ENERGY CODE OR MAXMAXIMUM NOTES: ASHRAE 90.1 WHEN TESTED PER AMCA STD 500. AIR HANDLING EQUIPMENT: MECHMECHANICAL PACKAGE ROOFTOP UNITS SHALL BE PROVIDED BY THE CONTRACTOR. MCMECHANICAL CONTRACTOR 1.UNITS SHALL BE FURNISHED WITH MERV8 REPLACEABLE MEDIA FILTERS. CONTROLS & OPERATION MEPMECHANICAL, ELECTRICAL AND PLUMBING Design Forum 2.EXTEND FULL SIZE CONDENSATE DRAIN LINE TO ROOF DRAIN OR AS INDICATED. FILTERS MFGMANUFACTURER WHEN AN EMS SYSTEM IS NOT BEING PROVIDED, THE FOLLOWING COMPONENTS AND 3.PROVIDE SMOKE DETECTOR IN RETURN AIR. PROVIDE THREE (3) SETS OF PLEATED DISPOSABLE FILTERS. USE ONE SET UNTIL COMPLETION MINMINIMUM REQUIREMENTS SHALL BE PROVIDED. Engineering OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION AND DELIVER ONE4.PROVIDE MANUFACTURER'S STANDARD 14" HIGH FULL UNIT CURB TO MATCH ROOF SLOPE. SET OF FILTERS TO STARBUCKS LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING UNIT. 5.UNITS SHALL HAVE 100% DRY BULB ECONOMIZER AND BAROMETRIC RELIEF WITH POWER EXHAUST. VERIFY EXISTING RTUS HAVE THESE FEATURES AND ADD NTSNOT TO SCALE Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 CONTROL WIRING FILTERS TO BE FARR, OR SIMILAR. IF THEY DO NOT. Cincinnati, OH 45203Professional Engineer THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT License: Tel: (513) 421-2210 6.PROVIDE VENSTAR SURVEYOR MODEL CT414 PROGRAMMABLE TWO STAGE THERMOSTAT WITH REMOTE TEMPERATURE SENSOR. O.D.OUTSIDE DIMENSION NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM EXHAUST FANS OSAOUTSIDE AIR 7.PROVIDE INTEGRAL DISCONNECT SWITCH. INCLUDING ALL MODES OF OPERATION AND INTERLOCK. ROOF MOUNTED, CENTRIFUGAL EXHAUST FAN(S) SHALL BE MANUFACTURED BY GREENHECK 8.ROOFTOP UNIT SHALL BE TESTED AND OPERABLE AND HAVE A ONE (1) YEAR COMPLETE UNIT WARRANTY AND A FIVE (5) YEAR COMPRESSOR WARRANTY. AND SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. THE PMPROJECT MANAGER THERMOSTAT CONTRACTOR IS RESPONSIBLE FOR COORDINATING DISCHARGE LOCATION WITH NEW AND 11/01/17 THERMOSTAT(S) SHALL BE VENSTAR PROGRAMMABLE SERIES CT414 AND REMOTE SENSOR(S) EXISTING VENTS AND INTAKES. PROVIDE A COMPLETE INSTALLATION INCLUDING DUCTWORK REFREFERENCE FROM RESTROOM GRILLES TO UNIT AND NECESSARY ACCESSORIES. EXHAUST FAN(S) TO BEAC0401 FURNISHED AND INSTALLED PER LEASE. REQ('D)REQUIRE(D) EXHAUST FAN SCHEDULE (EXISTING) OPERATED IN CONJUNCTION WITH AIR HANDLING UNIT(S). CONTRACTOR SHALL PROVIDE ONE REVREVISION YEAR WARRANTY ON ALL PARTS AND LABOR. ONE THERMOSTAT AND SENSOR IS PROVIDED FOR EACH AIR HANDLING UNIT. MOUNT RGRETURN GRILLE THERMOSTAT(S) AND SENSOR(S) IN LOCATION & HEIGHTS AS INDICATED ON DRAWINGS. RTROOFTOP TYPECFMS.P.MANUFACTURERMODELCONTROLREMARKS SONESHPVOLTSPH.FAN RPMTIP SPEED UNIT NO. AIR CURTAINS MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT IDENTIFICATION LABELS WITH 1/8" (3MM) AIR CURTAINS, WHEN REQUIRED, SHALL BE FURNISHED AND INSTALLED BY THE GENERAL HIGH WHITE LETTERS ON KELLY GREEN OR BLACK PHENOLIC BACKGROUND, I.E. SHTSHEET EF-1 (EXISTING)ROOF3000.156.61/3012011550-GREENHECKG-70-D-1,2 CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF POWER "AC-1:WORKROOM" AND "AC2:CUSTOMER AREA". REFER TO THERMOSTAT SETUP SPECSSPECIFICATION(S) CONNECTION. INSTRUCTIONS BELOW FOR ADDITIONAL REQUIREMENTS. SFSQUARE FEET NOTES: SSTSTAINLESS STEEL DUCTWORK AND ACCESSORIES THERMOSTAT SETUP INSTRUCTIONS 1. INTERLOCK EXHAUST FAN TO RUN WHENEVER RTU SERVING RESTROOMS IS RUNNING. PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE THERMOSTAT: TEMPTEMPORARY 2. STATIC PRESSURE INCLUDES DUCTWORK AND AIR DEVICES ONLY. SHEETMETAL DUCTWORK 1. FOLLOW INSTRUCTIONS IN THE MANUAL WHICH COMES WITH THE THERMOSTAT. TYPTYPICAL 3. PROVIDE FAN WITH BACKDRAFT DAMPER AND FAN SPEED CONTROLLER. ALL DUCTWORK TO BE RIGID SHEETMETAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN 2. CONFIGURE AS FOLLOWS: Revision Schedule ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. FIBERGLASS 4. PROVIDE FAN WITH ROOF CURB TO MATCH ROOF SLOPE. A. DEGREES "F" DISPLAY UNOUNLESS NOTED OTHERWISE RevDateDescription DUCTBOARD IS NOT ALLOWED. ALL EXPOSED DUCTWORK TO BE SPIRAL ROUND, OR B. 12 HOUR CLOCK RECTANGULAR LOCK-SEAM TYPE, AS SHOWN ON HVAC PLAN SHEET. ASSEMBLE AND INSTALL C. CONTINUOUS FAN OPERATION IN OCCUPIED MODE WHWATER HEATER DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIRTIGHT D. DISABLE KEYBOARD PROGRAMMING WSHPWATER SOURCE HEAT PUMP (5% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF 3. SET CLOCK AND DAY. PERFORMING EACH INDICATED SERVICE. FURNISH AND INSTALL ALL REQUIRED DAMPERS, AIR DISTRIBUTION DEVICES 4. SET TO DISPLAY CURRENT TEMPERATURE TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR 5. SET OCCUPIED START TIME AT 30MIN BEFORE OPENING. SET UNOCCUPIED START COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE VOLUME TIME AT 30MIN AFTER CLOSING. VERIFY HOURS WITH STORE MANAGER OR QUANTITY DESCRIPTIONPROVIDED BY TYPEFINISHTITUS MODEL NO. OR AS NOTED PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. CONTROL CONSTRUCTION MANAGER 6. SET POINTS SHALL BE AS FOLLOWS: MODEL TDC, 24"X24", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS, 4-WAY ACEILING SUPPLY DIFFUSERYESWHITECONTRACTOR6 DUCTWORK SHALL BE NEW GALVANIZED PRIME GRADE STEEL WITH GAUGES AND BRACING MECHANICAL SYMBOL LEGEND CONFORMING TO THE LATEST ASHRAE GUIDE AND DATA BOOK. ALL PANELS OF RECTANGULAR MODEL TDC, 24"x24", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS, 4-WAY BCEILING SUPPLY DIFFUSERYESWHITECONTRACTOR1 OR SQUARE DUCT 12" AND LARGER SHALL BE CROSS-BROKEN. MODEL TDC, 12"x12", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS, 4-WAY CCEILING SUPPLY DIFFUSERYESWHITECONTRACTOR2 B. UNOCCUPIED AT CONTRACTOR'S OPTION, FLEXIBLE DUCTWORK MAY BE USED FOR RUNOUTS TO DIFFUSERS. PRODUCT SHALL BE AS MANUFACTURED BY OWENS CORNING, CERTAIN-TEED, OWL-FLEX, OR MODEL 350RL, 12"x12", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS DCEILING EXHAUST GRILLEYESWHITECONTRACTOR2 DUCT HEATER TYPICAL SUPPLY DUCT UP/DN APPROVED EQUAL AND SHALL MEET REQUIREMENTS OF UL 181 CLASS 1.FLEXIBLE DUCTWORK 7. SET TWO (2) HOUR OCCUPIED OVERRIDE FUNCTION TO PROVIDE THE FOLLOWING SET MODEL TDC, 24"x24", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS, 4-WAY ECEILING SUPPLY DIFFUSERYESWHITECONTRACTOR5 SHALL HAVE INNER SLEEVE, INSULATION (MIN 1/2" THICK, R-5), OUTER MOISTURE BARRIER POINT OVERRIDES: MANUAL VOLUME JACKET, AND SELF-SUPPORTING FORM. DUCTWORK SHALL BE INSTALLED WITH MINIMUM OF TYPICAL RETURN OR MODEL TDC, 24"x24", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS, 4-WAY FCEILING SUPPLY DIFFUSERYESWHITECONTRACTOR4 DAMPER TURNS & SHALL NOT BE BENT OR KINKED. AIR DISTRIBUTION SYSTEM AS SHOWN ON DRAWINGS EXHAUST DUCT UP/DN IS DESIGNED FOR METAL DUCTWORK. FLEX SYSTEMS SHALL BE MODIFIED AS REQUIRED TO MODEL 350RL, 24"x24", MOUNT TYPE TO MATCH ARCH. PLANS , NECK SIZE ON PLANS GCEILING RETURN GRILLEYESWHITECONTRACTOR2 BACK DRAFT DAMPER MEET OR EXCEED AIR QUANTITIES SHOWN. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5'-0" IN EXHAUST FANS MODEL 350RL, 24"x24", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS STRETCHED LENGTH. HCEILING RETURN GRILLEYESWHITECONTRACTOR2 TURNING VANES RESTROOM EXHAUST FAN(S) TO BE OPERATED IN CONJUNCTION WITH STORE HOURS UNLESS OTHERWISE NOTED/APPROVED. FAN TO BE CONTROLLED THROUGH INTERLOCK WITH AIR MODEL 350RL, 24"x24", MOUNT TYPE TO MATCH ARCH. PLANS, NECK SIZE ON PLANS ICEILING RETURN GRILLEYESWHITECONTRACTOR2 SMOKE DETECTOR EXPOSED DUCTWORK: HANDLER SERVING RESTROOMS. WHERE DUCTWORK IS TO BE EXPOSED TO VIEW IN OCCUPIED SPACES, PROVIDED MATERIALS J EF-1YESWHITECONTRACTOR EQUIPMENT DESIGNATION WHICH ARE FREE FROM VISUAL IMPERFECTIONS INCLUDING PITTING, SEAM MARKS, ROLLER COMBINATION ENERGY MANAGEMENT SYSTEM (EMS) S MARKS, STAINS AND DISCOLORATIONS, AND OTHER IMPERFECTIONS, INCLUDING THOSE WHICH SMOKE AND FIRE WOULD IMPAIR PAINTING. SHEET METAL FOR EXPOSED DUCTWORK SHALL BE GALVANIZED AND TTHERMOSTAT DAMPER WHEN AN ENERGY MANAGEMENT SYSTEM IS TO BE INSTALLED, THE CONTRACTOR SHALL MILL PHOSPHATIZED WITH SURFACES PREPARED FOR PAINTING. NECK SIZE COORDINATE WITH THE EMS VENDOR FOR A COMPLETE SYSTEM. FURNISH AND INSTALL ALL SPIN-IN TAKE-OFF STHERMOSTAT SENSOR LOW VOLTAGE WIRING THROUGH EC PROVIDED CONDUITS (COORDINATE WITH ELECTRICAL). AND VOLUME CFM DO NOT USE METAL STRAPS OR WIRE TO SUPPORT DUCTWORK EXPOSED IN FINISH SPACES. DAMPER EXPOSED DUCTWORK SHALL BE SUPPORTED BY ALL-THREAD RODS, AND CIRCUMFERENTIAL EMS VENDOR TO PROVIDE ONE THERMOSTAT AND REMOTE SENSOR PER HVAC UNIT. LOCATE TYPE SUPPLY AIR ARROWUNDERCUT DOOR STRAPS (FOR ROUND DUCTS) OR UNISTRUT TRAPEZE HANGERS (FOR RECTANGULAR DUCTS). U AND MOUNT THERMOSTATS AND SENSORS PER THE DRAWINGS. PROVIDE THERMOSTAT IDENTIFICATION LABELS PER SPECIFICATION REQUIREMENTS. ALL EXPOSED DUCTWORK SHALL BE GALVANIZED STEEL DOUBLE-WALL INSULATED ROUND, RETURN AIR ARROWCONNECT TO EXISTING SPIRAL OR RECTANGULAR LOCK-SEAM TYPE. THERMAL DOUBLE-WALL DUCT IS REQUIRED FOR ENERGY MANAGEMENT SYSTEM (EMS) DEVICES VENDOR TO PROGRAM AND COMMISSION CONTROL SYSTEM. EMS THERMOSTATS TO BE CONDENSATION CONTROL. DUCT TO BE CONSTRUCTED OF A SOLID SHELL SURROUNDED BY A PROGRAMMED TO MEET LOCAL CODE REQUIREMENTS. LAYER OF INSULATION (R-6.0) AND COVERED BY A SOLID OUTER SHELL. QUANTITY DESIGN IDDESCRIPTIONRESPONSIBILITYCOMMENTS INDICATES UNLINED 12" X 8" O.D. SHEETMETAL PROJECT NAME:PROJECT ADDRESS: SMOKE DETECTORS CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY DO NOT USE FLEX DUCTWORK IN EXPOSED AREAS. 1ST FIGURE = SIDE SHOWN 12 X 8 PROVIDED & INSTALLED BY EMS VENDOR: VENSTAR. CONTACT: SBUXQUOTES@VENSTAR.COM, 818-812-9805 DATA CONCENTRATOR, VENSTAR DC400-E2 X02001SB 2ND FIGURE = SIDE NOT SHOWN PROVIDE DUCT SMOKE DETECTORS IN THE SUPPLY AND RETURN DUCT (AS REQUIRED BY DUCT SEALANT: THERMOSTAT, VENSTAR CT414 X02013CONTRACTOR STORE #:8123 LOCAL CODE) OF EACH RTU THAT HAS A SUPPLY AIR FLOWRATE OF 2000 CFM OR GREATER SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON-HARDENING, NON-MIGRATING INDICATED 14" X 10" O.D. SHEETMETAL W/ 12 X 8 (NOMINAL 5-TON OR LARGER), RTU SHALL BE DE-ENERGIZED UPON DETECTION OF SMOKE. MASTIC OR LIQUID ELASTIC SEALANT, WITH VOC CONTENT NO GREATER THAN 250G/L AND OF ATEMPERATURE SENSOR, VENSTAR AC0401 X02023CONTRACTOR 1" SOUNDLINER (U.N.O), 12" X 8" I.D. NET PROJECT #:25450-048 TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET PROVIDED & INSTALLED BY EMS VENDOR: VENSTAR. CONTACT: SBUXQUOTES@VENSTAR.COM, 818-812-9805 EQUIPMENT CONTROL PACK, VENSTAR MODEL ECP400-2 X02033SB TESTING, ADJUSTING, BALANCING METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN-IN FITTINGS, AND CONCEPT: FASTENING SCREWS WITH MASTIC. FLEXIBLE DUCT CONNECTIONPROVIDED & INSTALLED BY EMS VENDOR: VENSTAR. CONTACT: SBUXQUOTES@VENSTAR.COM, 818-812-9805 OUTDOOR SENSOR, VENSTAR ACC0400 X02041SB MECHANICAL CONTRACTOR OR AN INDEPENDENT NEBB OR AABC CERTIFIED AIR BALANCE PALETTE: SUPPORTS:CONTRACTOR SHALL ACCURATELY BALANCE THE AIR SYSTEMS TO PROVIDE AIR QUANTITIES PROVIDE HOT-DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND11/1/17 INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. OPERATE AUTOMATIC CONTROLSISSUE DATE: FLEXIBLE DUCT ANGLES FOR SUPPORT OF DUCTWORK. SYSTEM AND VERIFY SET POINTS DURING BALANCING. SUBMIT TWO (2) COPIES OF THE PROGRAM MANAGER:KIRBY MEINDL BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OF THE BALANCE VENTILATION SCHEDULE DAMPERS: REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT. R LEED AP: PROVIDE OPPOSED-BLADE, MULTI-LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON 12" O NECK SIZE BASE O.A.TOTAL O.A. OCCUPANT AREA, OCCUPANTS PEROCCUPANTO.A. PER PERSON,O.A., CFMAREA O.A., ROOMVENT DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST DUCTS WHERE CONTRACTOR SHALL OPERATE ALL SYSTEMS UNTIL THE SATISFACTORY PERFORMANCE OF SERVED BY PRODUCTION DESIGNER:PETER CHEETHAM REQUIRED (CFM)REQUIRED (CFM) O.A., CFM SQ. FT.1000 SQ. FT. PER SQ. FT. NAMELOADCFMCFMEFF. BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL LISTED FIRE OR FIRE/SMOKE SPECIFICATION REQUIREMENTS IS DEMONSTRATED TO THE COMPLETE SATISFACTION OF THE CD-1400 DESIGN CFM (WHERE APPLICABLE) CHECKED BY:DON RETHMAN DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE 809-547.54050.181465500.8688RTU-3 RESTAURANT (EXPANSION) OWNER. PRIOR TO, AND DURING OPERATION, ALL CONTROLS AND OTHER APPURTENANCES DIFFUSER TYPE (REFER SCHEDULE) CONVENIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE AND DEVICES SHALL BE ADJUSTED AND CALIBRATED. 540-327.52430.18973400.8426RTU-2 RESTAURANT EXISTING DAMPERS. PROVIDE MOTORIZED DAMPERS AT ALL INTAKE & EXHAUST BUILDING OPENINGS IN 4087.5150.1249640.880RTU-2 BEV. PREP.-2 SHEET TITLE: ACCORDANCE WITH LOCAL CODES. COORDINATE WITH OTHER TRADES FOR ACCESS PANELS, THE CONTRACTOR, DURING OPERATION AND BALANCING PERIODS, SHALL INSTRUCT THE 792-35150.12951100.8138RTU-1 WORKROOM POWER & FIRE ALARM INTERFACES. OWNER IN THE OPERATION AND CONTROL OF THE SYSTEMS AND MAINTENANCE SCHEDULE. MECHANICAL NOTES CEILING DIFFUSER (FLOW ARROWS SHOWN TOTAL - 1065TOTAL - 1331 ONLY IF AIR FLOW NOT SYMMETRICAL) 1. NOTES:SET OUTSIDE AIR AS CALLED OUT ON THE RTU SCHEDULE. 2. OUTSIDE AIR BASED ON CODE OCCUPANCY LISTED ON SHEET G-0001. SCALE: As Indicated CEILING RETURN / EXHAUST GRILLE SHEET: M-0001 MECHANICAL PLAN NOTES SHEET NOTES 1.SEE SHEET M-0001 FOR EQUIPMENT & AIR DEVICE SCHEDULES. 1.EXISTING ROOFTOP AC UNIT RTU-1 ON ROOF TO REMAIN. DESIGN INTENT IS TO REUSE AIR BALANCE SCHEDULE (CFM) RTU-1 AND RTU-2 AND TO INVESTIGATE THE POSSIBILITY OF REUSING AS MUCH 2.MECHANICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF DUCTWORK AND AIR DEVICES AS POSSIBLE AS LONG AS THEY ARE THE SAME SIZES OR WORK TO REVEAL FULL SCOPE OF PROJECT. EQUIVALENT SIZES AS THE DUCT AND AIR DEVICES SHOWN ON THIS PLAN. WHEREVER DUCT ARRANGEMENT IS SUBSTANTIALLY DIFFERENT AND NOT OF EQUIVALENT SIZE AND 3.COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTIONS TO ALL WHENEVER AIR DEVICES ARE NOT OF THE SAME SIZE NECK AS SHOWN ON THIS PLAN SO MECHANICAL EQUIPMENT. THEY CAN BE REUSED, PROVIDE NEW DUCT AND AIR DEVICES SIZED AS SHOWN. FINAL DESIGN SOLUTION WILL BE DETERMINED THROUGH MUTUAL AGREEMENT OF 4.DUCTWORK ABOVE CEILINGS SHALL BE ROUTED AS HIGH AS POSSIBLE. REFER TO CONTRACTOR, STARBUCKS' CONSTRUCTION MANAGER AND ENGINEER OF RECORD PER R CEILING PLANS AND SECTIONS FOR HEIGHT OF EXPOSED DUCTWORK. MECHANICAL PLAN NOTE 4. C 2011 STARBUCKS COFFEE COMPANY 5.CONTRACTOR SHALL INSTALL REFRIGERANT PIPING TO/FROM REMOTE CONDENSER FOR 2.EXISTING ROOFTOP AC UNIT RTU-2 ON ROOF TO REMAIN. SEE SHEET NOTE 1 THAT ICE MACHINE AND/OR WALK IN COOLERS. REFER TO SPECIFICATIONS, SHEET M-0001. APPLIES HERE. CONTRACTOR TO INVESTIGATE AND REPAIR LEAK FOR RTU-2. CEILING TILE SHOWS THERE IS A LEAK. STARBUCKS COFFEE 6.PRIOR TO START OF CONSTRUCTION CONTRACTOR SHALL GENERATE AN AS-BUILT SKETCH OF EXISTING RTU-1 AND RTU-2 DUCT AND AIR DEVICE LAYOUT INCLUDING ALL 3.PROVIDE NEW ROOFTOP AC UNIT RTU-3; NEW DUCTWORK AND NEW AIR DEVICES. COMPANY DUCT SIZES, TRANSITIONS, AND AIR DEVICE NOMINAL DIAMETER (E.G., 24"X24" VS. 2401 UTAH AVENUE SOUTH 4.FULL SIZE SUPPLY AIR DISCHARGE DUCT WITH 1-1/2" DUCT LINER. SEATTLE, WASHINGTON 98134 A PRELIMINARY AIR BALANCE TO DETERMINE THE AIRFLOWS OF THE EXISTING HVAC SYSTEMS AND AIR DEVICES AND HAVE THE BALANCER SHOW EXISTING AIRFLOWS ON 5.FULL SIZE RETURN AIR DUCT WITH 1-1/2" DUCT LINER. (206) 318-1575 THE AS-BUILT SKETCH AS WELL AS IN THE TYPICAL AIR BALANCE REPORT FORMAT THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL USUALLY GENERATED. THE CONTRACTOR SHALL SUBMIT COPIES OF THE AS-BUILT 6.WALL MOUNTED THERMOSTATS FOR ROOFTOP AC UNITS. MULTIPLE THERMOSTATS REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE SKETCH AND PRELIMINARY AIR BALANCE REPORT TO THE STARBUCK'S CONSTRUCTION SHALL BE STACKED IN VERTICAL CONFIGURATION WITH A MINIMUM 8" CLEARANCE BELOW REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR MANAGER AND THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL. THEN, THE EACH THERMOSTAT. CONFIRM EXACT LOCATION WITH OWNER. THERMOSTAT FURNISHED USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CONTRACTOR CAN CONSULT THE STARBUCKS CONSTRUCTION MANAGER TO CHOOSE WITH RTU. CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED EITHER TO 1) ADD A PROPOSED DESIGN SOLUTION TO A COPY OF THE AS-BUILT SKETCH TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT THEY GENERATED TO REUSE EXISTING DUCT AND AIR DEVICES, OR 2) ADD ENTIRELY 7.REMOTE TEMPERATURE SENSOR FURNISHED BY GC WITH RTU. (INSTALLED BY ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) NEW DUCT AND AIR DEVICES AS SHOWN ON PLANS. THE AS-BUILT SKETCH AND CONTRACTOR). UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. PRELIMINARY AIR BALANCE ARE BOTH REQUIRED REGARDLESS OF WHETHER 1) DUCT AND AIR DEVICES ARE REUSED, OR 2) NEW DUCT AND AIR DEVICES ARE PROVIDED PER8.10" DIAMETER EXHAUST DUCT UP TO EXISTING EXHAUST FAN EF-1. DESIGN INTENT IS TO PLANS. IF THE CONTRACTOR DESIRES TO REUSE DUCT AND AIR DEVICES SERVING REUSE EXISTING EF-1 AND PROVIDE NEW DUCTWORK AND AIR DEVICES. RTU-1 AND RTU-2, THE CONTRACTOR SHALL PROPOSE AN HVAC DESIGN SOLUTION BY Design Forum COPYING AND THEN ADDING THEIR PROPOSED SOLUTION TO THE AS-BUILT SKETCH.,9.MANUAL BALANCE DAMPER (TYPICAL). AND THEY SHALL SUBMIT A COST ESTIMATE FOR THE DESIGN SOLUTION THAT REUSES 10.SMOKE DETECTOR IN RETURN AIR STREAM TO SHUT DOWN UNIT UPON DETECTION (BY DUCT AND AIR DEVICES. CLEARLY SHOW WHAT EXISTING DUCT AND AIR DEVICES WILL Architects Inc. REMAIN AND ALL NEW DUCT AND AIR DEVICES WITH SIZES, CONNECTION POINTS, ANDLANDLORD). Donald J. Rethman 700 W. Pete Rose Way, Suite 460 Architect In Charge Cincinnati, OH 45203 PROPOSED ARRANGEMENT. CHOOSE ONLY THE AIR DEVICES IN THE BEST CONDITION License: Tel: (513) 421-2210 TO REUSE. NEW AIR DEVICES SHOULD BE SELECTED TO MATCH THE EXISTING TO 11. REMAIN AND EXISTING RELOCATED TYPE AIR DEVICES AND SHOULD BE EQUAL TO TITUS A355 MODELS SHOWN IN AIR DEVICE SCHEDULE ON SHEET M-0001. PROVIDE THE PROPOSED DESIGN SOLUTION INCLUDING COST ESTIMATE TO BOTH THE STARBUCK'S Design Forum CONSTRUCTION MANAGER AND ENGINEER OF RECORD FOR REVIEW AND APPROVAL. AT 12. COMPLETION OF CONSTRUCTION, BALANCE AIR DEVICES TO AIRFLOWS AS DIRECTED BY Engineering STARBUCK'S CONSTRUCTION MANAGER AND SUBMIT THE FINAL BALANCE REPORT TO B120 Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 THE STARBUCKS' CONSTRUCTION MANAGER AND ENGINEER OF RECORD. FIELD VERIFY Cincinnati, OH 45203Professional Engineer ALL REQUIREMENTS AND INCLUDE ALL COST IN BIDS FOR A COMPLETE SYSTEM. License: Tel: (513) 421-2210 13. 7.CONTRACTOR SHALL INSTALL REFRIGERANT PIPING TO/FROM REMOTE CONDENSER FOR C75 ICE MACHINE AND/OR WALK IN COOLERS. REFER TO SPECIFICATIONS, SHEET M-0001. 11/01/17 14. D150 15. E480 16. F600 Revision Schedule 26 13 RevDateDescription 4 75 CFM 17. 26 10 26 G1130 11 5 9 1111 18. 24 14 26 12 120 CFM H945 26 26 RTU-3 3 19. 9 S 7 I855 26 26 111111 26 20.PROVIDE COMBINATION FLUE/COMBUSTION AIR VENT FROM WATER HEATER TO GC PROVIDED 24 FLUE VENT. PIPING MATERIAL AS RECOMMENDED BY WATER HEATER MANUFACTURER FOR 14 150 CFM USE IN A RETURN AIR PLENUM. FIELD VERIFY FLUE LOCATION AND SIZE. (TYP OF 2) 13 1717 355 CFM (TYP OF 6) 75 CFM 21.LOCATION OF REMOTE AIR CONDENSER FOR ICE MACHINE. REFER TO DETAIL ON SHEET 1130 CFM EACH M-5001. FIELD VERIFY ALL REQUIREMENTS AND INCLUDE ALL COST IN BIDS FOR A COMPLETE (TYP OF 2) SYSTEM. 945 CFM EACH 251824 15 24 (TYP OF 2) 22.EXISTING AIR DEVICE TO REMAIN, ONLY IF POSSIBLE TO REUSE PER MECHANICAL PLAN NOTE 6. 25 10 10 2225 23.REMOVE EXISTING AIR DEVICE AND SAVE FOR RELOCATION, ONLY IF POSSIBLE TO 5 24 16 18 5 REUSE PER MECHANICAL PLAN NOTE 6. 9 25 EF-1 8 24.NEW LOCATION OF AIR DEVICE, ONLY IF POSSIBLE TO REUSE PER MECHANICAL PLAN 1 FOOT REQ'D NOTE 6. EXTEND DUCT FROM AIR DEVICE TO EXISTING SUPPLY OR RETURN OR 9 22 2323232323 EXHAUST AIR DUCTS. 16 RTU-2 2 1515 2424 4 25.EXHAUST AIR DEVICE TO BE REMOVED AND RELOCATED, ONLY IF POSSIBLE TO REUSE 15 4 24 CLEARANCE PER MECHANICAL PLAN NOTE 6. RTU-1 1 5 & 6 21 M5001 26.REMOVE EXISTING AIR DEVICE. STARBUCKS DOES NOT ALLOW AIR DEVICES FROM PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY 480 CFM ANOTHER TENANT SPACE TO BE REUSED. (TYP OF 5) STORE #:8123 S 7 S 7 1919 PROJECT #:25450-048 22 CONCEPT: 2323 855 CFM EACH (TYP OF 2) PALETTE: 22 15 16 24 11/1/17 ISSUE DATE: 16 600 CFM (TYP OF 4) PROGRAM MANAGER:KIRBY MEINDL 20 R LEED AP: T PRODUCTION DESIGNER:PETER CHEETHAM TT CHECKED BY:DON RETHMAN 4 6 SHEET TITLE: M5001 MECHANICAL PLAN SCALE: As Indicated SHEET: N HVAC PLAN SCALE: 1/4" = 1' -0' M-1101 EXISTING ROOFTOP AIR HANDLING UNIT ROUND INSUL STUB DUCT SAME SIZE AS FLEX DUCT AIR AND WATERTIGHT PENETRATION, TYP. OPPOSED BLADE DAMPER TITUS STRUCTURAL EXPANSION BOLT AG-75 OR EQUAL BY G.C. WHEN JOIST REF PLAN FLASHING AND COUNTER SHOP FABRICATED SHEET METAL R REQ'D INSERT & BOLT FLASHING CEILING DIFFUSER CAP NET INSIDE C 2011 STARBUCKS COFFEE COMPANY UNISTRUT DIM. SAME AS DIFFUSER NECK FLEX DUCT CLAMP HANGER ROOF UP OVER CURB BY FLEX DUCT. PULL INSIDE CONDENSATE HANGER STRAP LANDLORD LINER TAUT STARBUCKS COFFEE THREADED ROD DRAINAGE LOW EQUALIZING GRID PERPEND. TO STUB DUCT - SELF TAPPING COMPANY EXPOSED PRESSURE FULL SIZE OF DIFFUSER CAP, HEIGHT FROM SCREWS 2401 UTAH AVENUE SOUTH SPIRAL DUCT DUCT DIFFUSER NECK TO STUB CENTERLINE. REF PLAN FACTORY CURB SUPPLIED SEATTLE, WASHINGTON 98134 FABRICATE FROM 22 GA PERF SHEET METAL WITH UNIT INSTALLED BY (206) 318-1575 (3/16" HOLES ON 1/4" CENTERS). LANDLORD THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL FOR DUCTS OVER 48" WIDE, REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS FRAMING SUPPORT FOR THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE TURN UNDER BOTTOM OF DUCT SIZEHANGER SIZEMAX. SPACING REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR PENETRATIONS BY DUCT & FASTEN USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS UP THRU 2 SQ. FT.1" x 1/16"8'-0" TYP SUSP LAY-IN CEILING NOTES: LANDLORD PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED 1.PROVIDE SUPPORT FOR DIFFUSER AND 2 THRU 4 SQ. FT.1" x 1/8"8'-0" TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT CAP PER CODE.CEILING DIFFUSER. FASTEN TO CAP W/ ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY 4 THRU 10 SQ. FT.1" x 1/8"6'-0" INSTALL FLEXIBLE CONNECTION BELOW REFER TO MECHANICAL OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) 2.EQUALIZING GRID REQ'D ON SUPPLY AIRSHEET METAL SCREWS, MIN ONE PER SIDE. UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. ROOF DECK AND CONNECT NEW OVER 10 SQ. FT.1" x 1/8"4'-0" PLAN FOR DUCT SIZES, TYP. DIFFUSERS ONLY.SEAL JOINT AIR TIGHT. DUCTWORK TO UNIT DUCT CONNECTIONS Design Forum RTU DETAILLAY IN DIFFUSERDUCT HANGING DETAIL 123 Architects Inc. N.T.S.N.T.S.N.T.S. Donald J. Rethman 700 W. Pete Rose Way, Suite 460 Architect In Charge Cincinnati, OH 45203 License: Tel: (513) 421-2210 Design Forum Engineering Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 Cincinnati, OH 45203Professional Engineer License: Tel: (513) 421-2210 FAN SPEED CONTROL SWITCH FIELD FABRICATED ALUMINUM MOUNTED IN CEILING. FURNISHED BY 11/01/17 B-2 N1 SLOPE COVER TO DRAIN WATER SHEET METAL HOOD. PROGRAMMABLE T-STAT MECHANICAL INSTALLED BY ELECTRICAL SEAL AT PENETRATION PATE ROOF CURB, STYLE OF PIPES. PC-2A. SET BASE OF CURB T7350 SUBBASE ON DECK SURFACE, CAP SLOPE PIPE AWAY AND FLASH. AFROM HOOD. AUXILLARY 1 EF-1 } RELAY FASTENERS APPROX. 6" O.C. ALONG CONTACTS HOOD ENCLOSURE. A SHEET METAL OR FLEX TUBE 2 COLLAR, INSULATE. FIBER CANT Revision Schedule 2 BASE FLASHING DECK INSULATION RevDateDescription RELAY REQUIRED (R8222 OR SIMILAR) 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD 2 ROOF DECK PACK INSULATION PROTECTION AS REQUIRED 24 VAC SECONDARY VERIFY BETWEEN PIPE AND CURB. TRANSFORMER SIZE WITH LOAD SERVED PIPE PIPE ROOF CURB DETAIL PROGRAMMABLE T-STAT 5 4 N.T.S. N.T.S. AIR COOLED CONDENSER SECURE CONDENSER TOSECURE STRAPS TO STAND STAND WITH FOUR (4) 14WITH FOUR (4) #14 X 1-1/4" GAUGE STEEL STRAPS ANDSCREWS #14 X 1-1/2" SCREWS SUPPORT FRAME ON ROOF- METALLUM ENTERPRISES PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY NOA #14-1224.10 INSTALL 5" X 5" X 5/16" STORE #:8123 ANGLE ACROSS ROOF JOISTS. WELD TO BOTTOM PROJECT #:25450-048 OF TOP CHORD. ROOF DECK OR GRADE MOUNTED EQUIPMENT PAD CONCEPT: 1/8" PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL CONDENSER SUPPORT DETAIL R 6 LEED AP: N.T.S. PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN SHEET TITLE: HVAC LOAD CALCULATION MECHANICAL DETAILS 6 N.T.S. SCALE: As Indicated SHEET: M-5001 ABBREVIATIONSSECURITY SYSTEM NOTESLEED SYSTEM COMMISSIONINGGENERAL ELECTRICAL NOTES ELECTRICAL SYMBOL LEGEND STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING AFFABOVE FINISHED FLOOR1.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL JUNCTON BOXRECEPTACLE: DUPLEX J AND INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE AHJAUTHORITIES HAVING JURISDICTIONWORK AND SPECIFICATIONS WITH OTHER TRADES. THE INSTALLATION OF SECURITY SYSTEM FOR FOUR (4) TIMES;CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED, NEEDED APPROXAPPROXIMATEARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE 1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLEAND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS STAFF BUILDING PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE SWITCHRECEPTACLE: DUPLEX - ONE INSTALLER PRIOR TO DRYWALL INSTALLATION.COMMISSIONING EFFORTS. THIS WORK WILL BE COMPRISED OF THREE BLDGBUILDINGDISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING SWITCHED 2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTSDISTINCT EFFORTS: DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON PANEL, KEYPAD AND SENSORS. 1)SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING CKTCIRCUITELECTRICAL DETAILS ARE SHOWN FOR REFERENCE AND 3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR.INSTALLATION VERIFICATION AND CORRECT DISCLOSED DEFICIENCIES; CLGCEILINGCOORDINATION ONLY. SEE SPECIFICATION SHEETS FOR THREE-WAY SWITCHRECEPTACLE: QUADPLEX R 4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND2)PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP AND CMSTARBUCKS CONSTRUCTION MANAGERELECTRICAL SPECIFICATIONS 3 TRAIN PARTNERS AFTER POS INSTALL.SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS CXA; CONSTCONSTRUCTION C 2011 STARBUCKS COFFEE COMPANY 3)CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE CWCOLD WATER2.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER M MOTION (OCCUPANCY)DATA OUTLET SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FORTESTING AND SUBMIT REPORTS. CONTRACTOR SHALL PERFORM AND CXACOMMISSIONING AGENTOPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE SENSOR SWITCH EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONALPROVIDE THE FOLLOWING: PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHEST PHASE LOAD INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE DEGDEGREESIN EACH PANEL BOARD. STARBUCKS COFFEE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THEA.SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE NOT DLLIGHTS WITHIN DAYLIGHT ZONE SWITCHBACKRECEPTACLE: FLOOR DUPLEX S RESPONSIBILITY OF THE CONTRACTOR.LIMITED TO DOMESTIC HOT WATER GENERATION, HVAC SYSTEMS, DMSTARBUCKS DESIGN MANAGER3.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE- COMPANY ROOFTOP UNITS, EXHAUST FANS, HVAC CONTROLS, LIGHTING DNDOWNENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE 2401 UTAH AVENUE SOUTH CONTROLS, AIR CURTAINS, BUILT-IN REFRIGERATION EQUIPMENT, DTLDETAILCONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING SEATTLE, WASHINGTON 98134 TELEPHONEGROUNDING ELECTRODE AND RENEWABLE ENERGY SYSTEMS. DWG(S)DRAWING(S)LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE CONNECTION (206) 318-1575 USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT TELEPHONE SYSTEM NOTES B.CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN EAEACHCONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE ECELECTRICAL CONTRACTOR THERMOSTAT (EMS)NIGHTLIGHTING 24HR/DAY REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS NL OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND ECPEQUIPMENT CONTROL PAC4.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE STANDARD REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA. EGEXHAUST GRILLESYSTEM OUTAGES WITH THE GENERAL CONTRACTOR AND SINGLE LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL CONTRACTOR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL ELECELECTRICALLANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS THERMOSTAT SENSORSHALL CONTACT STARBUCKS PRIOR TO BEGINNING CONSTRUCTION TO PHOTOELECTRIC CELL (EMS) CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED S DL WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM IN EMEMERGENCYOTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND (EMS) ORDER THE ADDITIONAL TELEPHONE LINE(S). REPORT ANY TELEPHONE TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE THE SCHEDULE OF VALUES. EMSENERGY MANAGEMENT SYSTEM5:00AM. (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT INSTALLATION ISSUES IMMEDIATELY TO STARBUCKS. ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY EXISTEXISTING OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) D C.CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH EXTEXTERIOR5.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. DIMMER SWITCHSPEAKER CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE EXISTING, NECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETE WORKING TELCO FACILITIES TO THE BUILDING OR THAT LANDLORD HAS DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED TOTALLY F&IFURNISH & INSTALLSECURITY, PHONE, POS AND DATA SYSTEMS. SEE MANAGER FURNISHED AND INSTALLED ONE (1) 2" (51MM) MIN. (ENTRANCE) CONDUIT COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR FLRFLOORWORKSTATION AND BAR POINT OF SALE (POS) INCLUDING PULL STRING FROM TELCO STREET FEED LINE TO THE BUILDING SPECIAL RECEPTACLE: SEE NOTE/SCHEDULE FOR DETAILS INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE FTFOOT/FEETPOWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE AS IDENTIFIED BY THE PHONE COMPANY. NOTIFY STARBUCKS Design Forum TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION LOCATIONS AND MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR CONSTRUCTION MANAGER IMMEDIATELY IF FACILITIES OR COUDUIT AND VERIFICATION. GCGENERAL CONTRACTORTO ROUGH-IN. PROVIDE END-TO-END PULL STRINGS IN ALL PULL STRING ARE NOT INSTALLED. GFCIGROUND FAULT CIRCUIT INTERRUPTERCONDUITS. LABEL EACH END OF THE PULL STRING WITH CONDUIT RACEWAY CONCEALED IN CEILING OR WALL. HASH MARKS Architects Inc. D.INSTALLATION VERIFICATION SHALL BE PERFORMED BY STARBUCKS GNDGROUND INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN. Donald J. Rethman 700 W. Pete Rose Way, Suite 460 CXA. CONTRACTOR SHALL SUPPORT STARBUCKS CXA PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED OTHERWISE NOTED. TWO WIRES PLUS GROUND IF NO HASH CONDUIT WITH PULL STRING FROM THE DATA RACK TO THE DEMARC Architect In Charge Cincinnati, OH 45203 INSTALLATION VERIFICATION EFFORTS AS NECESSARY. PROVIDE HRHOURCONDUIT ENDS. License: Tel: (513) 421-2210 MARKS SHOWN. LONG HASH MARK DENOTES NEUTRAL. DOT (TELCO TO CUSTOMER HAND OFF EQUIPMENT) WHEN THE DEMARC IS ALL ACCESS AND EQUIPMENT NECESSARY FOR STARBUCKS STAFF HVACHEATING, VENTILATION, AIR CONDITIONING DENOTES GROUND. MORE THAN 10' FROM THE DATA RACK. DISTANCES LESS THAN 10' WILL TO VERIFY THAT THE EQUIPMENT IS INSTALLED CORRECTLY. HWHOT WATER6.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL NOT REQUIRE CONDUIT. CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, E.CONTRACTOR SHALL BE READILY AVAILABLE DURING INSTALLATION LCPLIGHTING CONTROL PANELCEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY Design Forum ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE VERIFICATION TO CORRECT ANY DEFICIENCIES OR DEFECTS LLLANDLORDBECOME DAMAGED DURING THE COURSE OF WORK. TELEPHONE/NETWORK CABLING VENDOR. DISCLOSED BY THE INSTALLATION VERIFICATION PROCESS. LSLIGHT SENSOR PHOTOCELL Engineering CORRECTIONS SHALL BE MADE IN A TIMELY MANNER WITHOUT LVLOW VOLTAGE7.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED DISRUPTION OF THE CONSTRUCTION SCHEDULE. WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 Cincinnati, OH 45203Professional Engineer MAXMAXIMUM NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH License: Tel: (513) 421-2210 F.ALL HVAC, EXHAUST FAN, AND AIR CURTAIN EQUIPMENT SHALL BE MCMECHANICAL CONTRACTORSTARBUCKS CONSTRUCTION MANAGER FOR APPROVAL. MDPMAIN DISTRIBUTION PANEL POS \\ DATA LINE NOTES TESTING, ADJUSTING AND BALANCE AGENT( SEE TESTING, MECHMECHANICAL8.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ADJUSTING AND BALANCING) AFTER THE SYSTEM IS VERIFIED TO BE MEPMECHANICAL, ELECTRICAL, AND PLUMBINGARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO COMPLETE AND CORRECT BY STARBUCKS CXA, IN ACCORDANCE MFGMANUFACTURERGENERAL CONTRACTOR, EQUIPMENT VENDORS, STARBUCKS AND 11/01/17 SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS WITH THE REQUIREMENTS OF THESE DOCUMENTS. ALL HVAC MINMINIMUMEXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION FOR THE POINT OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE NLNIGHTLIGHTNEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH NTSNOT TO SCALETHAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION WAINSCOTS, TILE TRANSITIONS, ETC. SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN OCPOVERCURRENT PROTECTION AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER ACCORDANCE WITH THE CONTRACT REQUIREMENTS. SCHEDULES DELIVER OF CASH REGISTER/MANAGER'S WORKSTATION DELIVERABLES: PRELIMINARY, WRITTEN TESTING AND AIR BALANCE REFREFERENCE EQUIPMENT AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) REPORT CONFORMING TO THE REQUIREMENTS SPECIFIED HEREIN, REQUIRE(D) MONTH PRIOR TO STORE OPEN. CONTRACTOR TO VERIFY DELIVERY GENERAL NOTES DOCUMENTING THE INFORMATION SPECIFIED, ETC. TO THE REVREVISION SCHEDULE TWO (2) WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. STARBUCKS CXA IMMEDIATELY UPON COMPLETION OF THE WORK. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE. CONTRACTOR TO SFSQUARE FEET SCOPE ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE DELIVERY. G.CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN EQUIPMENT IS SHTSHEET THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A Revision Schedule READY FOR FUNCTIONAL PERFORMANCE TESTING. ALL EQUIPMENT SPECSSPECIFICATION(S) COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND SHALL BE READY FOR FUNCTIONAL PERFORMANCE TESTING PRIOR SSTSTAINLESS STEEL RevDateDescription CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER TO STARTING TESTING. CONTRACTOR SHALL OPERATE EQUIPMENT EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. LOCATIONS, MANAGER'S WORKSTATION, ALL OTHER NETWORKED FOR STARBUCKS CXA AND VERIFY BY DEMONSTRATION THE TELTELEPHONE EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR, ETC...) AND WIRELESS CORRECT OPERATION OF EQUIPMENT, RESPONSE OF SENSORS, TEMPTEMPORARY SITE EXAMINATION ACCESS POINT TO THE DATA RACK AREA. CONTRACTOR IS TO HAVE AND PROPER EXECUTION OF HVAC CONTROL AND LIGHTING TYPTYPICAL THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS CONDUIT WITH PULL STRING IN PLACE FOR ALL CABLE RUNS PRIOR TO SEQUENCES; INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL CABLE INSTALL DATE. TEMPERATURE, SOUND, AND CONTROL RESPONSE. PROVIDE ANY UNOUNLESS NOTED OTHERWISE REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER SECURITY ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT INSTALLATION OF THE ELECTRICAL WORK. STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING AS NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS WHWATER HEATER STARBUCKS POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WILL WPWEATHER PROOF STANDARDS VENDOR. THIS GROUP MAY BE CONTACTED AT: RECORD THE EQUIPMENT OPERATION AND RESPONSE TO TESTING EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE NEWSTORES@STARBUCKS.COM. SEQUENCES AND PREPARE A LIST OF ANY DEFICIENCIES PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE DISCLOSED BY THE FUNCTIONAL PERFORMANCE TESTS FOR TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CORRECTION BY THE CONTRACTOR. EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS, ROOFTOP AND SPLIT TYPE, CODES CONDENSING UNITS, EXHAUST FANS, LIGHTING CONTROLS, ETC. COMMUNICATION SYSTEM NOTES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL DELIVERABLES: PROVIDE COMPLETED COPIES OF ALL START UP APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF REPORTS, FILLED OUT ON THE MANUFACTURER'S FORMS, TO THE CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES, STARBUCKS CXA. CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE) SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY H.CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR CONDUIT INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE EXTRA COST TO STARBUCKS. DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL PERFORMANCE STREET FEED TO THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE TESTING PROCESS. CORRECTIONS SHOULD BE MADE IN A TIMELY PROVIDER. PERMITS AND FEES MANNER WITHOUT DISRUPTION TO THE SYSTEM AND THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, CONSTRUCTION SCHEDULE. FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. I.CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE-TESTING WARRANTY FIRE ALARM SYSTEM NOTES OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS CXA DURING THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A TESTING. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY ISSUES OR DEFICIENCIES FOUND IN THE SYSTEM DURING ANY AND ALARM MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK ALL RE-TESTING. CORRECTIONS SHOULD BE MADE IN A TIMELY SPECIFIED IN THE LEASE AGREEMENT, THE CONTRACTOR IS TO NOTIFY PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING MANNER WITHOUT DISRUPTION TO THE SYSTEM AND GNOC IMMEDIATELY THAT FIRE ALARM LINES ARE NEEDED. STARBUCKS WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND CONSTRUCTION SCHEDULE. DELIVERABLES: FINAL BALANCE PREFERRED FIRE ALARM SERVICE PROVIDER, STANLEY, IS TO BE WORKMANSHIP. REPORT, DEFICIENCIES LIST NOTING CORRECTIVE ACTIONS CONTACTED BY THE CONSTRUCTION MANGER TO INSTALL FIRE ALARM PERFORMED BY CONTRACTOR IN RESPONSE TO INSTALLATION PANEL AND/OR MONITORING SERVICE AS REQUIRED. LEED VERIFICATION AND FUNCTIONAL PERFORMANCE TEST RESULTS. ALL WORK, MATERIALS AND EQUIPMENT SHALL MEET LEED REQUIREMENTS & CODE. IN CASE OF CONFLICT, THE HIGHER STANDARD SHALL APPLY. J.CONSTRUCTION AND POST CONSTRUCTION TESTING: ADDITIONAL TESTING MAY BE REQUIRED BY LEED AND OTHER PROCESSES THAT PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY MAY OCCUR OUT OF SEQUENCE WITH COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT, DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS DIRECTED BY STARBUCKS CXA. STORE #:8123 CONTROLS AND OPERATION PROJECT #:25450-048 COORDINATE INSTALLATION OF LIGHTING CONTROL PANEL (IF APPLICABLE) AND ENERGY MANAGEMENT SYSTEM (EMS) WITH ENERGY MANAGEMENT CONCEPT: SYSTEM VENDOR. PALETTE: WIRELESS NETWORK NOTES FURNISH AND INSTALL RACEWAYS WITH PULLSTRINGS AND JUNCTION BOXES 11/1/17 ISSUE DATE: CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED BY PROGRAM MANAGER:KIRBY MEINDL COORDINATE WITH VENDOR AND PLANS FOR DEVICE LOCATIONS. THE VENDOR FOR FIBER OR BRAODBAND CONNECTIONS. T1 AND ETHERNET R LEED AP: EXTENSION CABLING IS PROVIDED BY THE STARBUCKS (TELEPHONE/ NETWORK) CABLING VENDOR. COORDINATE WITH STARBUCKS. PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN MUSIC SYSTEM NOTES SHEET TITLE: ELECTRICAL NOTES PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR NTS REFLECTED CEILING PLAND AND IN COORDINATION WITH ALL PLANS AND SCALE: As Indicated DETAILS. FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS. SHEET: E-0001 KEY NOTES PROVIDE WEATHERPROOF JUNCTION BOX 1 WITH DISCONNECT SWITCH. (1) 1" PVC CONDUIT FOR POWER CONNECTION TO MENU SIGN OR PRE-MENU SIGN AND (1) 1" PVC CONDUIT WITH PULL STRING CONTINUOUS TO TELEPHONE BOARD FOR DATA CONNECTION. VERIFY ALL ELECTRICAL REQUIREMENTS R WITH MANUFACTURER PRIOR TO ROUGH-IN. PROVIDE CONDUCTORS AND OVERCURRENT C 2011 STARBUCKS COFFEE COMPANY PROTECTION FOR A COMPLETE INSTALLATION. STARBUCKS COFFEE PROVIDE A WEATHERPROOF JUNCTION BOX 2 WITH DISCONNECT SWITCH. (1) 1" PVC COMPANY CONDUIT FOR POWER CONNECTION TO 2401 UTAH AVENUE SOUTH STARBUCKS DIRECTIONAL SIGNAGE. VERIFY ALL ELECTRICAL REQUIREMENTS WITH SEATTLE, WASHINGTON 98134 MANUFACTURER PRIOR TO ROUGH-IN. (206) 318-1575 PROVIDE CONDUCTORS AND OVERCURRENT THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL PROTECTION FOR A COMPLETE REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE INSTALLATION. REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CIRCUIT SERVING THIS DEVICE SHALL BE CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED 3 CONTROLLED BY LIGHTING CONTROL TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT SYSTEM. FURNISH AND INSTALL ALL CONDUIT, ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) WIRE, CONNECTIONS, AND CONTACTORS UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. NECESSARY TO ENSURE A FUNCTIONAL SYSTEM VIA THE LIGHTING CONTROL PANEL. REFER TO DETAILS SHEET E-5001 FOR ADDITIONAL INFORMATION. Design Forum PROVIDE WEATHERPROOF JUNCTION BOX 4 WITH DISCONNECT SWITCH. (1) 1" PVC Architects Inc. CONDUIT FOR POWER CONNECTION TO Donald J. Rethman 700 W. Pete Rose Way, Suite 460 DIGITAL ORDER SCREEN CONTROL BOX AND Architect In Charge Cincinnati, OH 45203 License: Tel: (513) 421-2210 (2) 1" PVC CONDUITS WITH PULL STRING CONTINUOUS TO DRIVE THRU WINDOW COMMUNICATIONS AREA AND MANAGER'S WORKSTATION DATA RACK FOR DATA/AUDIO Design Forum CONNECTIONS. VERIFY ALL ELECTRICAL REQUIREMENTS WITH MANUFACTURER PRIOR Engineering TO ROUGH-IN. PROVIDE CONDUCTORS AND Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 OVERCURRENT PROTECTION FOR A Cincinnati, OH 45203Professional Engineer COMPLETE INSTALLATION. License: Tel: (513) 421-2210 13 11/01/17 4 2 3 ELECTRICAL SITE PLAN NOTES Revision Schedule A.GC SHALL VERIFY FULL SCOPE OF RevDateDescription WORK WITH LANDLORD WORK LETTER PRIOR TO BID. NO EXTRAS OR CHANGE ORDERS SHALL BE M10894 GIVEN FOR THE GC'S FAILURE TO FULLY UNDERSTAND THE SCOPE. B.COORDINATE ALL CONDUIT ROUTING WITH ARCHITECTURAL AND CIVIL PLANS, AND OTHER TRADES. C.SIGN LOCATIONS ON THIS PLAN ARE FOR REFERENCE ONLY, ACTUAL LOCATIONS SHALL BE DETERMINED FROM THE ARCHITECTURAL AND CIVIL PLANS, AND THE CONSTRUCTION MANAGER. 23 D.REFER TO POWER PLAN FOR PANELBOARD LOCATIONS. PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY STORE #:8123 PROJECT #:25450-048 CONCEPT: PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL ELECTRICAL SITE PLAN R 1 SCALE: 3/32" = 1'-0" LEED AP: PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN SHEET TITLE: ELECTRICAL SITE PLAN NOTED SCALE: As Indicated SHEET: E-1001 ELECTRICAL DESIGN PLAN NOTES A.REFER TO ELECTRICAL DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. B.THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT AND PROVIDING BUCK-BOOST TRANSFORMERS AS MAY BE NEEDED FOR CODE. ALL ARE NOT NECESSARILY INDICATED. C.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) CONTRACTORS FOR ANY ADDITIONAL EQUIPMENT NEEDING POWER. D.ALL FUTURE EQUIPMENT NEEDED HEREIN SHALL BE PROVIDED WITH AN R APPROPRIATE RECEPTACLE AND FULLY WIRED. EVEN IF NOT SPECIFICALLY INDICATED. C 2011 STARBUCKS COFFEE COMPANY E.GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKERS (NOT RECEPTACLES) SHALL BE UTILIZED WHERE REQUIRED BY CODE AND AT ANY STARBUCKS COFFEE FLOOR BOXES. PROVIDE DEDICATED NEUTRAL WIRE FOR ALL THESE CIRCUITS. COMPANY F.EQUIPMENT REQUIRES CONNECTION TO THE BUILDING ELECTRICAL SYSTEM. 2401 UTAH AVENUE SOUTH FURNISH AND INSTALL ALL NECESSARY CONDUCT, WIRE, SEATTLE, WASHINGTON 98134 CONNECTIONS,RECEPTACLES AND OVERCURRENT PROTECTION (206) 318-1575 NECESSARY TO ENSURE THE EQUIPMENT FUNCTIONS PROPERLY AND COMPLIES WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL COORDINATE EQUIPMENT REQUIREMENTS WITH MANUFACTURER CUT REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE SHEET PRIOR TO ROUGH-IN. REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS G.ALL BACK BAR AND FRONT BAR J-BOXES AND OUTLETS SHALL BE SURFACE PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED MOUNTED. PROVIDE CONDUITS AS NEEDED AND ONE (1) ADDITIONAL SPARE TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE CONDUIT BETWEEN ALL J-BOXES FOR FUTURE ELECTRICAL REQUIREMENTS. (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY ALL J-BOXES SHALL BE POSITIONED TO AVOID OBSTRUCTION OF ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. EQUIPMENT SUCH AS REFRIGERATORS AND DISHWASHERS. H.REFERENCE LANDLORD WORK LETTER FOR DIVISION OF ELECTRICAL SCOPE OF WORK AND COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER. Design Forum Architects Inc. Donald J. Rethman 700 W. Pete Rose Way, Suite 460 Architect In Charge Cincinnati, OH 45203 License: Tel: (513) 421-2210 KEY NOTES FLOOR POWER/DATA: SEE ARCH DRAWINGS FOR EXACT DIMENSIONING OR Design Forum 1 LOCATION.. Engineering CUP LABELER OR MOBILE ORDER PRINTER: PROVIDE BACKBOX FOR DATA 2 Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 OUTLET MOUNTED AT 26" AFF. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA Cincinnati, OH 45203Professional Engineer RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING License: Tel: (513) 421-2210 AND PROVIDE PULL STRING FROM END TO END. 9999 ALL BACK BOX AND FRONT BAR J-BOXES AND OUTLETS SHALL BE SURFACE 3 MOUNTED. PROVIDE CONDUITS AS NEEDED AND (1) ADDITIONAL SPARE 11/01/17 CONDUIT BETWEEN ALL J-BOXES FOR FUTURE ELECTRICAL REQUIREMENTS. ALL J-BOXES SHALL BE POSITIONED TO AVOID OBSTRUCTION OF ANY EQUIPMENT SUCH AS REFRIGERATORS AND DISHWASHERS. EXISTING EQUIPMENT BEING RELOCATED. EXTEND EXISTING CIRCUITRY TO 4 NEW EQUIPMENT LOCATION SHOWN. NOT USED 5 DRIVE THRU AIR CURTAIN: PROVIDE HARD WIRED CONNECTION TO FACTORY 6 Revision Schedule 1 INSTALLED DISCONNECT SWITCH; FIELD VERIFY MOCP IS 40A; NOTIFY 1 RevDateDescription ENGINEER IF MOCP IS ANYTHING OTHER THAN 40A. DRIVE THRU AUTOMATIC SLIDER WINDOW: PROVIDE (1) CONDUIT AND J-BOX 7 WITH 120V, 20A BRANCH CIRCUIT. SEE MANUFACTURER'S SPECIFICATIONS FOR FURTHER REQUIREMENTS. RECEPTACLE MOUNTED AT 80" AFF FOR ELECTRIC RELEASE DRIVE THRU 8 WINDOW. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. PROVIDE CONNECTION TO FURNITURE. 9 1 1 4 SEE E-5001 GROUND FAULT PROTECTION 2 NOTES: 3 4 PROVIDE GFCI PROTECTION AS REQUIRED BY NEC 201.8. PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY 4 CIRCUITS REQUIRING GFCI PROTECTION IDENTIFIED WITH * STORE #:8123 ON PANEL SCHEDULES (SEE E-6001). ABOVE-COUNTER RECEPTACLES THAT ARE READILY PROJECT #:25450-048 ACCESSIBLE AND WITHIN REACH OF PARTNERS SHALL BE CONCEPT: GFCI TYPE. 2 4 PALETTE: BELOW-COUNTER RECEPTACLES, OR RECEPTACLES THAT ARE DIFFICULT TO REACH OR REQUIRE MOVING 11/1/17 ISSUE DATE: EQUIPMENT TO RESET, AND ARE NOT READILY ACCESSIBLE PROGRAM MANAGER:KIRBY MEINDL SHALL BE PROTECTED BY GFI CIRCUIT BREAKERS. 2 R LEED AP: WHERE THE AVAILABLE SHORT CIRCUIT CURRENT EXCEEDS 22,000 AMPS AT THE PANELBOARD, CONTACT CIRCUIT PRODUCTION DESIGNER:PETER CHEETHAM BREAKER MANUFACTURER AND PROVIDE GFCI TYPE CHECKED BY:DON RETHMAN CIRCUIT BREAKER THAT SERIES RATES WITH PANEL OVER CURRENT PROTECTION IF AVAILABLE. SHEET TITLE: WHERE THE AVAILABLE SHORT CIRCUIT CURRENT EXCEEDS ELECTRICAL DESIGN 22,000 AMPS AT THE PANELBOARD, AND GFCI BREAKERS ARE NOT AVAILABLE, PROVIDE DEAD-FRONT GFCIS (IN A 678 PLAN READILY ACCESSIBLE LOCATION) TO SERVE RECEPTACLES THAT ARE NOT READILY ACCESSIBLE. NOTED SCALE: As Indicated POWER PLAN SHEET: 1 SCALE: 1/4" = 1'-0" E-1101 KEY NOTES EXISTING CONTROLS AND DEVICES IN THIS AREA SHALL REMAIN. CONNECT 1 NEW LIGHTING TO EXISTING CONTROLS FOR ROOM. 2CONNECT TO EXISTING BOH LIGHTING CIRCUIT & CONTROLS. CONNECT NEW LIGHTING TO EXISTING CIRCUITRY & CONTROLS FOR "BACKBAR 3 LIGHTING". 4CONNECT NEW LIGHTING TO EXISTING CIRCUITRY & CONTROLS FOR "SEATING AREA LIGHTING". R RELOCATE EXISTING FIXTURE(S) AND ASSOCIATED EQUIPMENT. EXTEND C 2011 STARBUCKS COFFEE COMPANY 5 EXISTING CIRCUITRY AND CONTROLS AS REQUIRED. PROVIDE NEW OCC SENSOR TO CONTROL EXISTING ROOM LIGHTING AND NEW STARBUCKS COFFEE 6 FIXTURES (AS INDICATED). COMPANY RELOCATED SWITCH BANK LOCATION: EXTEND ALL EXISTING CIRCUITRY TO 2401 UTAH AVENUE SOUTH 7 THIS LOCATION AND PROVIDE NEW SWITCHING TO MATCH EXISTING CONTROL SEATTLE, WASHINGTON 98134 LAYOUT. (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. Design Forum Architects Inc. LIGHTING DESIGN PLAN NOTES 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge License: Tel: (513) 421-2210 A.ALL FIXTURES IN WORK ROOM, BACK AND FRONT LINE, ABOVE CONDIMENT CART, AND ANY OTHER AREAS WHERE EXPOSED FOOD, CLEAN EQUIPMENT OR UTENSILS, OR UNWRAPPED Design Forum SINGLE SERVICE ITEMS WILL BE EXPOSED, SHALL HAVE SHATTERPROOF LAMPS IF THE FIXTURE IS NOT LENSED. ARCHITECT OF RECORD TO INCLUDE APPROPRIATE LAMPS / Engineering FIXTURES ON DRAWINGS AND SCHEDULES, AND COMPLY WITH 700 W. Pete Rose Way, Suite 460Timothy L. Raberding ANY ADDITIONAL JURISDICTIONAL LIGHTING REQUIREMENT. (14) L 14743 (11) L 12869 Professional Engineer Cincinnati, OH 45203 Tel: (513) 421-2210License: B.PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR (11) L13827 L14359 (2) L12869 FIXTURES/SUPPORTS. (2) L13827 C.CENTER EMERGENCY/EXIT LIGHTS ABOVE DOORS, UNLESS OTHERWISE NOTED. 11/01/17 D.ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCHANDISE BAYS. E.IF PENDANT CYLINDERS CAN SUSPENDED LENGTH EXCEEDS 48" (1220MM) FROM CEILING, REPLACE WITH SURFACE 2 MOUNTED CYLINDER CANS AND SUSPEND WITH GENERAL CONTRACTOR SUPPLIED CONDUIT AND J-BOX TO 6 DIMENSIONED HEIGHT. L 11611 F.REFER TO POWER PLAN FOR PANELBOARD LOCATIONS. (2) L12869 4 5 (2) L13827 Revision Schedule RevDateDescription 4 5 L11611 6 2 (2) L14895 3 (2) L12869 (2) L13827 (45) L 11458 (45) L13242 (45) L14518 L 14359 4 5 2 L11611 1 PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY 3 2 STORE #:8123 PROJECT #:25450-048 7CONCEPT: 3 PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL (5) L14743 R LEED AP: PRODUCTION DESIGNER:PETER CHEETHAM (2) L12869 CHECKED BY:DON RETHMAN (2) 2L13827 SHEET TITLE: 2 LIGHTING DESIGN PLAN (3) L11649L15057 SCALE: As Indicated SHEET: LIGHTING PLAN E-1102 1 SCALE: 1/4" = 1'-0" DATA DEVICE SCHEDULE - "A" RESPONSIBILITY LEGEND ELECTRICAL DESIGN IDCOUNTDESCRIPTIONRESP.COMMENTS SB-GCFURNISHED BY STARBUCKS - INSTALLED BY GENERAL AUDIO VISUAL DESIGN PLAN NOTES CONTRACTOR 100051MUSIC SYSTEMSB-GC A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE 100101DT ORDER MONITORSB-GC SB-SBFURNISHED BY STARBUCKS - INSTALLED BY STARBUCKS NOT NECESSARILY SHOWN. 100121DT COMMUNICATION SYSTEMSB-GC B.ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO 3 GC-GCFURNISHED BY GENERAL CONTRACTOR - INSTALLED BY 10017SPEAKER SURFACE MOUNTEDSB-GCINTERIOR: BLACK; VERIFY START OF WORK TO REVEAL FULL SCOPE OF WORK. GENERAL CONTRACTOR PLACEMENT PER RCP & ELEVATIONS C.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. 100761AMPLIFIER - 14IN 355MMSB-GC LL-LLFURNISHED BY LANDLORD - INSTALLED BY LANDLORD D.REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF 123361DT TIMER SYSTEMSB-GC ELECTRICAL DEVICES. 146761DT POS MONITOR ARM DOUBLESB-GC R SURFACE MOUNTEDE.THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT AND PROVIDING BUCK-BOOST DATA NOTE: ALL RESPONSIBILITIES TO BE CONFIRMED WITH STARBUCKS C 2011 STARBUCKS COFFEE COMPANY TRANSFORMERS AS MAY BE NEEDED FOR CODE. ALL ARE NOT NECASSARILY DESIGN MANAGER PRIOR TO ORDERING/CONSTRUCTION. 100002PHONE 1 LINESB-GC INDICATED. 100021COMPUTER MANAGERSB-GC WORKSTATIONF.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HEATING, STARBUCKS COFFEE VENTILATING, AND AIR CONDITIONING (HVAC) CONTRACTORS FOR ANY 100071PRINTER MANAGERSB-GC ADDITIONAL EQUIPMENT NEEDING POWER. WORKSTATION COMPANY 100111EQUIPMENT RACK - 6FT 183CMSB-GC G.ALL FUTURE EQUIPMENT NEEDED HEREIN SHALL BE PROVIDED WITH AN 2401 UTAH AVENUE SOUTH APPROPRIATE RECEPTACLE AND FULLY WIRED. EVEN IF NOT SPECIFICALLY 100191WIDE AREA NETWORK HARDWARESB-GC ELECTRICAL SYMBOLS LEGEND SEATTLE, WASHINGTON 98134 INDICATED. POINT OF SALE (206) 318-1575 100082POS - REGISTER WITH COMPACTSB-GC H.GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKERS (NOT RECEPTACLES) TELEPHONE THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL CASH DRAWER SHALL BE UTILIZED WHERE REQUIRED BY CODE AND AT ANY FLOOR BOXES. REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE DATAPROVIDE DEDICATED NEUTRAL WIRE FOR ALL THESE CIRCUITS. 100144POS PRINTERSB-GC REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR 100221MONEY COUNTERSB-GC USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS I.EQUIPMENT REQUIRES CONNECTION TO THE BUILDING ELECTRICAL SYSTEM. PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS T THERMOSTAT 100296POS BANKSB-GC FURNISH AND INSTALL ALL NECESSARY CONDUIT, WIRE, CONNECTIONS, CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE RECEPTACLES AND OVERCURRENT PROTECTION NECESSARY TO ENSURE THE 100755CUP LABELERSB-GC (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT C CARBON MONOXIDE MONITOR O ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY EQUIPMENT FUNCTIONED PROPERLY AND COMPLIES WITH ALL APPLICABLE 146771POS - DT TENDERING REGISTERSB-GC OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) LOCAL AND NATIONAL CODES. COORDINATE EQUIPMENT REQUIREMENTS WITH UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. 146781POS - DT EXPEDITORSB-GC JUNCTION BOX MANUFACTURER CUT SHEET PRIOR TO ROUGH-IN. SECURITY J.ALL BACK BAR AND FRONT BAR J-BOXES AND OUTLETS SHALL BE SURFACE 100041ALARM SYSTEMSB-GC MOUNTED. PROVIDE CONDUITS AS NEEDED AND (1) ADDITIONAL SPARE 100241SAFE LH - 20X18X26INSB-GC CONDUIT BETWEEN ALL J-BOXES FOR FUTURE ELECTRICAL REQUIREMENTS. Design Forum 510X455X660MM ALL J-BOXES SHALL BE POSITIONED TO AVOID OBSTRUCTION OF ANY 100281SAFE BASESB-GC EQUIPMENT SUCH AS REFRIGERATORS AND DISHWASHERS. Architects Inc. K.STUB-UP POWER, DATA, AND PHONE CONDUITS 6" AFF IN THIS LOCATION. Donald J. Rethman 700 W. Pete Rose Way, Suite 460 ROUTE POWER CONDUCTORS IN FLEXIBLE METAL CONDUIT TIGHT TO WALL Architect In Charge Cincinnati, OH 45203 License: Tel: (513) 421-2210 FROM RECEPTACLES TO NEARBY RIGID STUB-UP AND BACK TO SERVING POWER PANEL. ROUTE DATA AND PHONE CONDUITS UNDER FLOOR BACK TO DATA RACK NEAR MANAGER'S WORKSTATION. LABEL DATA AND PHONE CONDUITS "FOR DATA CABLING". PROVIDE INSULATED BUSHINGS, AND PROVIDE Design Forum PULL STRING FROM END TO END. L.COORDINATE ALL CONCRETE TRENCHING/CORE DRILLING TO ENSURE THAT Engineering ANY UNDER SLAB UTILITIES, ETC., ARE NOT DAMAGED DURING FLOOR CUT AND Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 OR CORE DRILLING. PRIOR APPROVAL AND COORDINATION WITH PROPERTY Cincinnati, OH 45203Professional Engineer MANAGEMENT IS REQUIRED FOR ALL CONCRETE WORK. EC SHALL PROVIDE License: Tel: (513) 421-2210 PATCHING/REPAIR TO CONCRETE AND VAPOR BARRIER AS REQUIRED. 11/01/17 KEY NOTES SAFE: PROVIDE RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT TO 1 RECEPTACLE, PROVIDE J-BOX FOR SECURITY ALARM JACK AND ROUTE CONDUIT BACK TO SECURITY PANEL J-BOX. REFER TO MANAGER'S DESK DETAIL AND POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. POS: PROVIDE RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT TO 2 RECEPTACLE, PROVIDE J-BOXES FOR TELEPHONE AND DATA. ROUTE CONDUIT(S) BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK Revision Schedule DETAIL AND POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. RevDateDescription STUB UP POWER, DATA PHONE AND/OR SECURITY CONDUITS 6" AFF TO 3 SERVE NEARBY DEVICES IN THIS LOCATION. ROUTE POWER CONDUCTORS IN FLEXIBLE METAL CONDUIT CONCEALED OR TIGHT-TO-WALL FROM RECEPTACLES TO NEARBY RIGID STUB UP AND BACK TO SERVING POWER PANEL. ROUTE DATA, PHONE AND SAFE CONDUITS UNDER FLOOR BACK TO DATA RACK NEAR MANAGER WORKSTATION. PROVIDE AN END-TO-END PULL STRING IN ALL DATA PHONE AND SAFE CONDUITS. LABEL EACH END OF PULL STRING WITH CONDUIT SYSTEM ("POS", "SECURITY", ETC..) AND DESTINATION ("DRIVE-THRU", "FRONT BAR", ETC..). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED CONDUIT ENDS. REFER TO ARCHITECTURAL PENETRATION PLAN FOR ADDITIONAL INFORMATION. CUP LABELER AND/OR MOBILE ORDER PRINTER: PROVIDE RECEPTACLE AND 4 ADJACENT DATA BACKBOX AT SAME MOUNTING HEIGHT - COORDINATE LOCATION AND MOUNTING HEIGHT WITH OWNER'S REPRESENTATIVE PRIOR TO ROUGH IN. ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORKSTATION. DT POS AND EXPEDITER TILL MONITOR: PROVIDE DOUBLE DUPLEX 5 RECEPTACLE ON DEDICATED CIRCUIT. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. DT EXPEDITER MONITOR: PROVIDE DOUBLE DUPLEX RECEPTACLE. 6 ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. DT TIMER CONTROL UNIT AND MONITOR: PROVIDE DOUBLE DUPLEX 7 RECEPTACLE. ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. 4 ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY DT TIMER SIGNAL PROCESSOR: PROVIDE DUPLEX RECEPTACLE. ADJACENT 3 8 3 TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND DRIVE-THRU STORE #:8123 POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. PROJECT #:25450-048 WIRELESS HEADSET BASE STATION: PROVIDE DUPLEX RECEPTACLE. 2 1 9 CONCEPT: ADJACENT TO RECEPTACLE, PROVIDE J-BOX FOR DATA. ROUTE CONDUIT 10075A BACK TO MANAGER'S DESK. REFER TO MANAGER'S DESK DETAIL AND PALETTE: DRIVE-THRU POS DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. 4 11/1/17 ISSUE DATE: 12 DATA OUTLET FOR FUTURE USE: PROVIDE BACKBOX MOUNTED AT 26" AFF. 4 10 PROGRAM MANAGER:KIRBY MEINDL ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S R WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL A 10014LEED AP: STRING FROM END TO END. 11 PRODUCTION DESIGNER:PETER CHEETHAM A10014 4 DATA OUTLET FOR RACK MOUNTED EQUIPMENT: REFER TO MANAGER'S 11 CHECKED BY:DON RETHMAN A10000A10011 DESK DETAIL ON E-5001 FOR ADDITIONAL INFORMATION. A10002A10019 A 10014 SHEET TITLE: DATA OUTLET FOR FUTURE USE: PROVIDE BACKBOX MOUNTED AT 26" AFF. A10004A10022 12 ROUTE 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S A10005A10076 5 ELECTRICAL LOW WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL 8 A10007 STRING FROM END TO END. VOLTAGE PLAN 6 NOTED SCALE: As Indicated LOW VOLTAGE PLAN 9 1 SCALE: 1/4" = 1'-0" SHEET: 7 E-1103 CEILING JUNCTION BOX FOR RELAY LINEDUPLEX RECEPTACLE FOR SECURITY PANEL AT 92" (2340MM) AFFPANEL AT 92" (2340MM) AFF JUNCTION BOX FOR HIGH SPEED QUADPLEX RECEPTACLE FOR INTERNET AND TELECOMMUNICATION SECURITY CAMERA POWER AT 92" (2340MM) AFF R 1" DIA CONDUIT ATTACHED TO DUPLEX RECEPTACLE FOR DRIVEDUPLEX RECEPTACLE FOR SUPPLIES AT 92" (2340MM) AFF TABLE BASE. COLOR TO MATCH. THRU TIMER SIGNAL PROCESSORWIRELESS HEADSET BASE STATION C 2011 STARBUCKS COFFEE COMPANY ROUTE POWER IN CONDUIT TO JUNCTION BOX FOR CONTINUOUS LOW PROFILE BLACK PLUG OUTLET IN FLOOR. DUPLEX RECEPTACLE FOR WIFI AT TELECOMMUNICATION MOLD MOUNTED PARALLEL TO TABLE TOP. DATA OUTLETDATA OUTLET88" (2285MM) AFF WIRING AT 92" (2340MM) AFF STARBUCKS COFFEE COMPANY JUNCTION BOX FOR SECURITY DRIVE THRU WIRELESS HEADSET BASE STATION EXPEDITER TILL MONITOR PANEL AT 92" (2340MM) AFF AND 15" 2401 UTAH AVENUE SOUTH (380MM) OVER FROM ADJACENT BOX SEATTLE, WASHINGTON 98134 (206) 318-1575 DRIVE THRU TIMER CONTROL UNIT TECH RACK THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL DRIVE THRU TIMER MONITOR REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR DATA OUTLETDATA OUTLET NETWORK HARDWARE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE DATA COMPUTER DOUBLE DUPLEX RECEPTACLE FORDOUBLE DUPLEX RECEPTACLE FOR (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY DRIVE THRU TIMER CONTROL UNITDRIVE THRU TIMER MONITOR OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. PRINTER SECURITY ALARM SYSTEM DRIVE THRU EXPEDITOR MONITOR DATA OUTLET LOCATE FLOOR OUTLET NEAR TABLE LEG DOUBLE DUPLEX RECEPTACLE FOR Design Forum AMPLIFIER DRIVE THRU BUMP BAR DRIVE THRU EXPEDITER MONITOR DUPLEX RECEPTACLE FOR MUSIC DUPLEX RECEPTACLE FOR Architects Inc. SYSTEM AT 48" (1220MM) AFF SECURITY AT 48" AFF 700 W. Pete Rose Way, Suite 460Donald J. Rethman Cincinnati, OH 45203Architect In Charge License: Tel: (513) 421-2210 DT REGISTEREXPEDITER TILL MONITORPC MONITOR DEDICATED DUPLEX RECEPTACLE FOR WORK-STATION AT 42" AFF Design Forum RECEIPT PRINTER Engineering CASH DRAWERS (TYP) MONEY COUNTER 2-LINE PHONE 700 W. Pete Rose Way, Suite 460Timothy L. Raberding POWER RECEPTACLES Professional Engineer Cincinnati, OH 45203 Tel: (513) 421-2210License: - RECEPTACLE FOR FUTURE ( ) LOCATE FLOOR OUTLET POS BANKS (TYP) CONTINUOUS LOW PROFILE BLACK PLUG MOLD FOR OUTLETS - RECEPTACLE FOR REFRIGERATOR ( ) NEAR TABLE LEG MOUNTED TO UNDERSIDE OF TABLETOP ON BOTH SIDES OF QUADPLEX CONVENIENCE CENTER SUPPORT. RUN ELECTRICAL ALONG SIDE SUPPORT DATA OUTLETDATA OUTLET RECEPTACLE AT 12" AFF AND DOWN TABLE LEG TO FLOOR OUTLET. HIDE ALL WIRING. 11/01/17 MANUFACTURER: LEGRAND MODEL 2000 SMALL RACEWAY. DOUBLE DUPLEX RECEPTACLE FOR DTDOUBLE DUPLEX RECEPTACLE FOR FUTURE JUNCTION BOX FOR 1 PHONE REGISTER & EXPEDITER TILL MONITOR JACK AT 12" (305MM) AFF SINGLE DOOR REFRIGERATOR PLUG MOLD DETAIL RE-WORK EXISTING CIRCUITRY AS REQUIRED FOR RENOVATION OF THIS 3 Scale: NONE AREA. MOVE AND EXTEND CIRCUITS/ DEVICES, ETC. AS REQUIRED RE-WORK EXISTING CIRCUITRY AS REQUIRED FOR RENOVATION OF THIS AREA. MOVE AND EXTEND CIRCUITS/ DEVICES, ETC. AS REQUIRED Revision Schedule LAN/POWER/PHONE/SECURITY SYSTEM ELEVATIONS RevDateDescription 1 Scale: NONE TO MANAGER'S DESK 1" EMT CONDUIT FOR ALL SECURITY1" EMT CONDUIT FOR ALL SECURITY DATA CABLES BETWEEN FRONT OFDATA CABLES BETWEEN FRONT OF HOUSE AND ALARM PANELSHOUSE AND ALARM PANELS 4" SQUARE BOX WITH 1" CONDUIT STUB-UP FOR SECURITY CABLING. INSTALL BEHIND FRONT COUNTER J-BOX FOR STROBE LIGHT - STEM MOUNT 6" BELOW CEILING J-BOX FOR EMERGENCY CALL PHONE - MOUNT AT 54" AFF POS MONITOR (TYP OF 2) J-BOX FOR ALARM KEYPAD - MOUNT AT 54" AFF CUP LABELER QUAD RECEPTACLE FOR SAFE BUILDINGSTARBUCKS SECURITY AND LABELER EXTERIORINTERIOR SPACE PHONE EXISTING 400A PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY SECONDARY TO REMAIN. DATA OUTLET FOR SAFE SECURITY POS BANK (TYP OF 4) STORE #:8123 DEDICATED DUPLEXRECEPTACLES FOR SCALES, CHECK RECEPTACLE FOR POSVALIDATION AND CASH DRAWERS PROJECT #:25450-048 EXISTINGEXISTING UTILITY CO. PANELPANEL PAD MOUNTED CONCEPT: NETWORK SWITCH AB TRANSFORMER SAFE (PROVIDED BY STARBUCKS VENDOR) PALETTE: 11/1/17 ISSUE DATE: JUNCTION BOX FOR PHONEDATA OUTLET FOR POS AND CUP LABELER PROGRAM MANAGER:KIRBY MEINDL R EXISTING LEED AP: POWER AND DATA STUB-UPS. PRODUCTION DESIGNER:PETER CHEETHAM SEE PENETRATION PLAN FOR FINAL LOCATION CHECKED BY:DON RETHMAN POS DETAIL 4 SHEET TITLE: Scale: NONE SCHEMATIC EXISTING GROUNDING ELECTRICAL DETAILS TO REMAIN EXISTING 400A RE-WORK EXISTING CIRCUITRY AS REQUIRED FOR RENOVATION OF THIS SECONDARY TO REMAIN. AREA. MOVE AND EXTEND CIRCUITS/ DEVICES, ETC. AS REQUIRED NTS SCALE: As Indicated SHEET: RISER DIAGRAM 5 Scale: NONE E-5001 B A ROOMVOLTS208Y/120V 3P 4WAIC22,000 ROOMVOLTS208Y/120V 3P 4WAIC22,000 MOUNTINGSURFACEBUS AMPS400MAIN BKR400 MOUNTINGSURFACEBUS AMPS400MAIN BKR400 FED FROM A NEUTRAL100%LUGSSTANDARD FED FROM UTILITY NEUTRAL100%LUGSFEEDTHRU CKTCKTCKTCKT KVA LOADKVA LOAD CKTCKTCKTCKT KVA LOADKVA LOAD ## ## ABCBKRBKRABC CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION ABCBKRBKRABC CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION 1** POS020/120/10** LIGHTS2 1** SAFE020/120/10** BLENDER2 R 3** POS020/14 40/22.5DRIVE THRU AIR CURTAIN 3** WARMING OVEN030/24 30/23TURBOCHEF 5** WATER HEATER340/36 |2.5 50 |6 |3 C 2011 STARBUCKS COFFEE COMPANY 0 73 |20/1** LIGHTS8 3 7** BREWER050/230/2TURBOCHEF8 93 |10 20/10** LIGHTS 90 |10 |3 11SC BAKERY CASE1.2520/212 20/11.3* INSTA-HOT 11** BREWER050/212 20/10.18* SERVER STAND STARBUCKS COFFEE 131.25 |20/11.3* INSTA-HOT14 130 |20/10.96* U.C. REFRIGERATOR14 COMPANY 15** D/T WINDOW020/116 20/11.9HAND DRYER 15** BREWER030/216 20/10.18DRIVE THRU WINDOW 2401 UTAH AVENUE SOUTH 17** RR GFIS020/118 20/11.9HAND DRYER 170 |18 20/10.18DRIVE THRU WINDOW 19** MGR DESK020/120/20.144REMOTE CONDENSOR20 SEATTLE, WASHINGTON 98134 19* DOUBLE DOOR FREEZER1.320/120/11.3* INSTA-HOT20 21** SECURITY020/122 |0.144 21* DOUBLE DOOR FREEZER1.320/122 20/10.96* U.C. REFRIGERATOR (206) 318-1575 23** DSL IG020/124 20/20** DISHWASHER 23* DOUBLE DOOR REFRIGERATOR1.0820/124 20/11.08SEATING CONVENIENCE RECEPT THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL 25** MGR DESK020/1 |026 25* DOUBLE DOOR REFRIGERATOR1.0820/120/10.72SEATING CONVENIENCE RECEPT26 REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE 27** MUSIC020/128 20/21WATER CHILLER 27* SINGLE DOOR FREEZER1.0220/128 20/10.72SEATING CONV RECS REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS 29** DLS SEC020/130 |1 29** ORDER POST020/130 20/10.72SEATING CONVENIENCE RECEPT PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED 31RTU-33.140/320/10** E/M LTS32 31* CUP LABELER0.820/120/10.18* COUNTER RECEPT32 TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT 333.1 |34 30/22.3ICE MACINE 33* U.C. REFRIGERATOR0.9620/134 20/10** SIGN ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY 353.1 |36 OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT STATED ABOVE) |2.3 35LIGHTING CONTROLS0.2520/136 20/10** SIGN UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. 0 37** D/T BUMP020/120/1** D/T BUMP38 3.1 37** RTU-13.3350/340/3** RTU-238 39** D/T BUMP020/140 20/10** D/T 393.33 |40 |3.1 41** D/T BUMP020/142 20/10** D/T BUMP 413.33 |42 |3.1 8.7913.916.4TOTAL CONNECTED KVA 24.631.529.3TOTAL CONNECTED KVA Design Forum 73.4119138TOTAL CONNECTED AMPS LUG LOAD: PANEL B8.7913.916.4205264246TOTAL CONNECTED AMPS LOAD TYPECONN. KVADEMAND KVALOAD TYPECONN. KVADEMAND KVA LOAD TYPECONN. KVADEMAND KVALOAD TYPECONN. KVADEMAND KVA Architects Inc. Donald J. Rethman 700 W. Pete Rose Way, Suite 460 LIGHTING00(125%)CONTINUOUS9.2911.6(125%) LIGHTING0.250.313(125%)CONTINUOUS9.2911.6(125%) Architect In Charge Cincinnati, OH 45203 LARGEST MOTOR9.32.33(125%)HEATING14.314.3(100%) License: LARGEST MOTOR102.5(125%)HEATING33.633.6(100%)Tel: (513) 421-2210 OTHER MOTORS00(100%)NONCONTINUOUS3.83.8(100%) OTHER MOTORS00(100%)NONCONTINUOUS4.524.52(100%) RECEPTACLES2.62.6(50%>10)KITCHEN EQUIP9.18.19(90%) RECEPTACLES7.767.76(50%>10)KITCHEN EQUIP29.919.5(65%) NONCOIN/DIVERSE00(N/A) NONCOIN/DIVERSE00(N/A) Design Forum TOTAL KVA:39.142.8 TOTAL KVA:85.479.8 NOTES: NOTES: TOTAL BALANCED DEMAND AMPS:119 Engineering TOTAL BALANCED DEMAND AMPS:221 * - PROVIDE GFCI TYPE CIRCUIT BREAKER * - PROVIDE GFCI TYPE CIRCUIT BREAKER Timothy L. Raberding 700 W. Pete Rose Way, Suite 460 ** - Existing load to remain ** - Existing load to remain Cincinnati, OH 45203Professional Engineer License: Tel: (513) 421-2210 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING LOADS AND SCHEDULES TO ENSURE ACCURACY OF EXISTING CONDITIONS. ADJUST CIRCUIT LOCATIONS CONTRACTOR SHALL FIELD VERIFY ALL EXISTING LOADS AND SCHEDULES TO ENSURE ACCURACY OF EXISTING CONDITIONS. ADJUST CIRCUIT LOCATIONS WITH FIELD CONDITIONS AND UPDATE PANEL DIRECTORIES ACCORDINGLY. WITH FIELD CONDITIONS AND UPDATE PANEL DIRECTORIES ACCORDINGLY. 11/01/17 Revision Schedule RevDateDescription PROJECT NAME:PROJECT ADDRESS: CARMEL, IN 46033 131ST & HAZEL DELL 13170 HAZEL DELL PKWY STORE #:8123 PROJECT #:25450-048 CONCEPT: PALETTE: 11/1/17 ISSUE DATE: PROGRAM MANAGER:KIRBY MEINDL R LEED AP: PRODUCTION DESIGNER:PETER CHEETHAM CHECKED BY:DON RETHMAN SHEET TITLE: PANELBOARD SCHEDULES NTS SCALE: As Indicated SHEET: E-6001