Loading...
HomeMy WebLinkAbout170223_ININD30035_BSA 04610101 St.V.Carmel CPD_100% Implementation Documents_Drawings9365 Counselors Row, Suite 300 Indianapolis, IN 46240.1479 ph 317.819.7878 fx 317.819.1479 www.bsalifestructures.com TM 4040 Vinvennes Circle Indianapolis, IN 46268 855-562-2824 Jeremy Fortier Jeremy.Fortier@ascension.org ARCHITECT MECHANICAL ENGINEERSTRUCTURAL ENGINEER ELECTRICAL ENGINEER ININD30035 04610101 1107 Burdsal Parkway P.O. Box 88126 Indianapolis, IN 46208 317-634-6112 317-617-4270 Clay Springer cspringer@jpsconsultingengineers.com 13500 N. MERIDIAN ST. CARMEL, IN 46032 100% CONTRACT DOCUMENTS FEB. 23, 2017 ST. VINCENT CARMEL HOSPITAL CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT G000 100% CONTRACT DOCUMENTS 05 - PLUMBING P001 PLUMBING SYMBOLS, ABBREVIATIONS AND GENERAL NOTES P200 PLUMBING PLANS 06 - ELECTRICAL E001 ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES E100 PARTIAL LOWER LEVEL ELECTRICAL PLANS E300 PARTIAL ROOF POWER PLAN 09- STERIS DRAWINGS 1 FOR REFERENCE ONLY 2 FOR REFERENCE ONLY 3 FOR REFERENCE ONLY 00- GENERAL G001 COMPOSITE PLAN & CODE SUMMARY R1 RTM LIFE SAFETY PLAN 02- STRUCTURAL S100 GENERAL NOTES AND TYPICAL DETAILS 03- ARCHITECTURE A100 DEMOLITION & DIMENSION PLAN A110 REFLECTED CEILING PLAN & INTERIOR ELEVATIONS 03.1- INTERIORS IF100 INTERIOR FINISH PLAN 04 - MECHANICAL H001 HVAC SYMBOLS, ABBREVIATIONS AND GENERAL NOTES HPE1 SEISMIC DETAILS AND SCHEDULES HPE2 TEMPERATURE CONTROL SCHEMATICS, DETAILS, SCHEDULES H100 PARTIAL HVAC PLANS H200 PARTIAL HVAC ROOF PLANS PROJECT INFORMATION: NAME: ST. VINCENT CARMEL ADDRESS: 13500 N MERIDIAN ST CARMEL, IN 46032 PROJECT DESCRIPTION: CENTRAL PROCESSING DEPTARTMENT WASHER REPLACEMENT PROJECT SF: XXX SF OWNER: ST. VINCENT CARMEL HOSPITAL ADDRESS: 13500 N MERIDIAN ST CARMEL, IN 46032 DESIGN PROFESSIONAL: ARCHITECT: BSA LIFESTRUCTURES ADDRESS: 9365 COUNSELORS ROW INDIANAPOLIS, IN 46240 CONTACT: CARL JOHNSON 317-819-7878 CJOHNSON@BSALS.COM CODE INFORMATION: 2012 INDIANA BUILDING CODE. 2014 INDIANA FIRE CODE 2014 INDIANA MECHANICAL CODE 2014 INDIANA PLUMBING CODE 2009 INDIANA ELECTRICAL CODE 2012 NFPA 101 - LIFE SAFETY CODE 2001 INDIANA HANDICAP ACCESSIBILITY CODE 2014 ADA STANDARDS FOR ACCESSIBLE DESIGN BUILDING DATA: OCCUPANCY: I-2 CONSTRUCTION TYPE: TYPE I, FULLY SPRINKLERED LIFE-SAFETY FEATURES: SPRINKLER SYSTEM THROUGH-OUT FIRE RATED SEPARATION WALLS FIRE RATED & SMOKE RESISTIVE CORRIDOR CONSTRUCTION SMOKE DETECTORS & FIRE ALARM SYSTEM EMERGENCY LIGHTS - BACK-UP EXIT LIGHTS - BACK-UP FIRE RESISTANCE RATING REQUIREMENTS: REFER TO RTM CONSULTANAT LIFE SAFETY PLAN SHHET R1 CODE SUMMARY PROJECT AREA 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\JSagen\Documents\04610101-ARCH_BSALS_CENTRAL_v2016_jsagen.rvt2/23/2017 11:34:57 AMFEB. 23, 2017 G001 COMPOSITE PLAN & CODE SUMMARY 100% CONTRACT DOCUMENTS CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT 1/16" = 1'-0"1 00- LOWER LEVEL COMPOSITE PLAN MARK DATE DESCRIPTION Travel Distance to Exit = 89'Travel Distance to Smoke Barrier = 171'Travel Distance to Smoke Barrier = 144'Travel Distance to Smoke Barrier = 135'Travel Distance to Exit = 97'Travel Distance to Exit = 92' NOTES: 1.G.C. SHALL COORDINATE PIT DEPTH & DIMENSIONS WITH EQUIPMENT MANUFACTURER. 2.SEISMIC ANCHORAGE IS NOT REQUIRED. 3.REPAIR OR REPLACE VAPOR RETARDER AS REQUIRED TO INSTALL RECESSED SLAB. L2x2x1/4 (CONT.) WITH 1/2"øx4" HEADED STUD @ 12" O.C. #3@18"O.C. x 2'-0" WITH 4" EPOXY EMBED DEPTH EXISTING SLAB ON GRADE #5@12" O.C. E.W. MIDDLE #5@12" O.C. E.W. MIDDLE FLUSH 8"9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH J:\Projects\16JPS140 ST V Carmel Cart Wash\Revit\ST V CARMEL CART WASH_v2016.rvt12/22/2016 8:36:19 AMFEB 23, 2017 CES JCB CES S100 GENERAL NOTES AND TYPICAL DETAILS 100% CONTRACT DOCUMENTS 1.REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS. 2.CONTRACTORS ARE REQUIRED TO COORDINATE THEIR RESPECTIVE WORK WITH ALL OTHER DISCIPLINES TO AVOID ANY CONFLICTS DURING CONSTRUCTION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE STRUCTURAL DRAWINGS WITH ALL OTHER CONSTRUCTION DOCUMENTS. 3.LOCATION, SIZES AND QUANTITY OF ALL OPENINGS MAY NOT BE COMPLETELY INDICATED ON THE STRUCTURAL DRAWINGS. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL OPENINGS WITH ALL OTHER DISCIPLINES PRIOR TO ANY FABRICATION. 4.CONTRACTORS ARE REQUIRED TO VERIFY EXISTING CONDITIONS PRIOR TO ANY FABRICATION OR CONSTRUCTION. IF EXISTING CONDITIONS ARE DIFFERENT THAN SHOWN, NOTIFY A/E IMMEDIATELY FOR MODIFICATIONS TO THE DRAWINGS. 5.THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO, BRACING, SHORING, UNDERPINNING, ETC. THE A/E IS NOT RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OR SAFETY PROCEDURES DURING CONSTRUCTION. GENERAL NOTES: GENERAL INFORMATION 1.ALL CONCRETE, UNLESS OTHERWISE NOTED IN SCHEDULES OR DETAILS, SHALL HAVE A MINIMUM 28 DAY CONCRETE COMPRESSIVE STRENGTH OF 4000 PSI. ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF). 2.ALL CONCRETE EXPOSED TO THE WEATHER SHALL BE AIR-ENTRAINED. FOR SURFACE FINISHES AND OTHER REQUIREMENTS, REFER TO THE CONCRETE SPECIFICATIONS. 3.DETAILS OF FABRICATION OF REINFORCEMENT, HANDLING AND PLACEMENT OF THE CONCRETE, CONSTRUCTION OF FORMS AND PLACEMENT OF REINFORCEMENT, NOT OTHERWISE COVERED BY THE PLANS AND SPECIFICATIONS, SHALL COMPLY WITH THE LATEST ADDITION OF THE A.C.I. CODE AND C.R.S.I. REQUIREMENTS. 4.ALL MISCELLANEOUS ITEMS TO BE INSTALLED IN ANY CONCRETE WORK, SUCH AS PIPES, ELECTRICAL CONDUITS, DOVETAIL ANCHOR SLOTS, REGLETS, ETC., SHALL BE PROPERLY LOCATED, INSTALLED AND CHECKED BY THE G.C. PRIOR TO PLACEMENT OF CONCRETE. REFER TO ARCHITECTURAL AND MEP DRAWINGS FOR THE EXACT EXTENT AND LOCATION OF THESE ITEMS THAT ARE NOT SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS. 5.PROVIDE SLEEVES FOR ALL PIPE AND CONDUIT PENETRATIONS IN FOUNDATION WALLS, GRADE BEAMS, WALL FOOTINGS AND TRENCH FOOTINGS TO TOTALLY SEPARATE THE PIPES FROM THE CONCRETE. REFER TO TYPICAL DETAILS. 6.NO HORIZONTAL CONSTRUCTION JOINTS SHALL BE MADE IN CONCRETE WALLS, FOOTINGS, BEAMS OR SLABS UNLESS SHOWN OR NOTED IN THE CONTRACT DRAWINGS. VERTICAL JOINTS ARE PERMITTED IN CONCRETE SLABS, WALLS, WALL FOOTINGS, TRENCH FOOTINGS AND GRADE BEAMS. REFER TO TYPICAL DETAILS. 7.ALL CONSTRUCTION JOINTS IN CONCRETE WALLS, FOOTINGS, BEAMS OR SLABS SHALL BE PROVIDED WITH A KEYWAY. THE SURFACE OF THE CONCRETE SHALL BE THOROUGHLY CLEANED AND ALL LATIANCE REMOVED. IN ADDITION, THE JOINT SHALL BE THOROUGHLY WETTED AND SLUSHED WITH A COAT OF CEMENT GROUT OR A BONDING AGENT IMMEDIATELY BEFORE PLACING CONCRETE. CONCRETE 1.ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH THE LATEST ADDITION OF ACI 315, ACI 318, AND CRSI. 2.REINFORCEMENT SHALL HAVE DEFORMED SURFACES IN ACCORDANCE WITH ASTM A615 WITH MINIMUM YIELD STRENGTH OF 60,000 PSI. 3.WELDED WIRE FABRIC SHALL BE SMOOTH CONFORMING TO ASTM A185. 4.THE SHOP DRAWINGS FOR REINFORCING STEEL SHALL INCLUDE SCALE ELEVATIONS OF ALL CONCRETE WALLS. 5.PROVIDE CORNER BARS AT ALL WALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. 6.REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE PROTECTION (CLEAR COVER) UNLESS OTHERWISE NOTED: - SURFACES NOT FORMED AND IN CONTACT WITH SOIL .................:3" - FORMED SURFACES IN CONTACT WITH SOIL OR WEATHER .........:2" - BEAMS, GIRDERS AND COLUMNS ......................................................:1 1/2" - SLABS, WALLS AND JOISTS ................................................................:3/4" 7.PROVIDE 50 BAR DIA. LAP SPLICES FOR #6 REBAR AND SMALLER AND 62 BAR DIA. LAP SPLICES FOR #7 REBAR AND LARGER. TYPICAL U.N.O. 8.PROVIDE ADDITIONAL REINFORCING BARS AROUND ALL OPENINGS IN CONCRETE SLABS AND WALLS EQUAL TO THE AMOUNT INTERRUPTED BY THE OPENINGS (1/2 EA. SIDE TYPICAL). WHERE OPENINGS ARE SUCH THAT THE REINFORCING STEEL IS NOT INTERRUPTED, NO ADDITIONAL REINFORCING IS REQUIRED. REFER TO TYPICAL CONCRETE OPENING DETAIL. 9.OPENINGS THROUGH CONCRETE WALLS, SLABS OR OTHER STRUCTURAL ELEMENTS NOT DETAILED ON THE STRUCTURAL DRAWINGS MUST BE LOCATED AND SHOWN ON THE APPLICABLE REINFORCING STEEL SHOP DRAWINGS. THE FINAL LOCATION OF ALL OPENINGS MUST BE REVIEWED BY THE A/E BEFORE THE CONCRETE IS POURED. 10.THE WELDED WIRE FABRIC IN THE CONCRETE SLAB-ON-GRADE SHALL BE SUPPORTED BY CONTINUOUS #4 SUPPORT BARS AT 2'-6" O.C. MAXIMUM. THE #4 BARS SHALL BE TIED AND SUPPORTED BY CONCRETE BRICK SPACERS (2 1/4" HIGH) AT 2'-6" O.C. MAXIMUM. REINFORCING STEEL 1" = 1'-0"S100 1 DETAIL MARK DATE DESCRIPTION CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT DECONTAM242526272930313334363839 A B.6 C G.6 H J x1 x2 x3 x4 x4 x5 x6 x7 x8 XX GENERAL DEMOLITION NOTES DEMOLITION SYMBOLS LEGEND EXISTING COLUMN LINE DEMOLITION NOTE DESIGNATION EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED EXISTING DOOR AND FRAME TO REMAIN EXISTING DOOR AND FRAME TO BE REMOVED EXISTING WINDOW AND FRAME TO REMAIN EXISTING WINDOW AND FRAME TO BE REMOVED 00 A.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND TEMPORARY DOORS AS DEEMED NECESSARY BY THE ARCHITECT, ENGINEER AND OWNER. THEY SHALL BE WELL MAINTAINED AND ANY DAMAGE REPAIRED IMMEDIATELY TO AVOID MIGRATION OF DUST INTO ADJOINING AREAS. B.THE CONTRACTOR SHALL COORDINATE ALL DEMOLITION WORK IN OCCUPIED SPACES AND SHALL NOTIFY THE OWNER TWO WEEKS PRIOR TO COMMENCING WORK. SUCH SPACES ARE TO REMAIN OCCUPIED DURING DEMOLITION AND ALL WORK SHALL BE PERFORMED IN SUCH A MANNER TO MINIMIZE DISRUPTIONS TO OCCUPANTS. PROTECT EXISTING FLOOR FINISHES FROM CONSTRUCTION TRAFFIC THROUGH OCCUPIED AREAS. EXISTING WALL, FLOOR AND CEILINGS FINISHES TO REMAIN SHALL BE PROTECTED AND ANY DAMAGE RESULTING FROM DEMOLITION WORK SHALL BE REPAIRED. C.WHEN DEMOLITION CAUSES DAMAGE TO FLOOR, WALL OR CEILING SURFACES THAT WILL REMAIN EXPOSED IN THE FINISHED WORK, SUCH DAMAGE SHALL BE REPAIRED AS REQUIRED TO RECEIVE NEW FINISHES. D.THE CONTRACTOR SHALL COVER AND PROTECT OWNER'S EQUIPMENT WHICH CANNOT BE REMOVED FROM THE PROJECT AREA. E.CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH ANY PHASING REQUIRED TO COMPLETE THE WORK. F.WHERE EXTERIOR WALLS, DOORS AND/OR WINDOWS ARE TO BE REMOVED OR MODIFIED, THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THAT THE EXISTING BUILDING REMAINS SECURE, WEATHER-TIGHT, AND WITHOUT DRAFTS. G.MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER SUITABLE TO ACCEPT NEW FINISHES AND/OR SURFACES. H.REMOVE ALL EXISTING WALL MOUNTED ITEMS WITHIN THE PROJECT LIMIT AREA WHICH ARE NOT NOTED TO REMAIN. THE CONTRACTOR SHALL DISPOSE OF THESE ITEMS AFTER INSPECTION BY THE OWNER FOR FUTURE USE. IF ITEMS ARE REMOVED FROM WALLS THAT ARE TO REMAIN, THE CONTRACTOR SHALL PATCH WALLS AS REQUIRED TO RECEIVE NEW FINISHES AND/OR SURFACES. I.DEMOLITION FOR BUILDING SERVICES AND UTILITIES SHALL BE PERFORMED BY THE TRADE RESPONSIBLE FOR THAT UTILITY. FOR EXAMPLE, PLUMBING FIXTURES SHALL BE DEMOLISHED BY THE MECHANICAL CONTRACTOR. OPENINGS FOR DEMOLISHED UTILITIES SHALL BE INFILLED BY TRADE RESPONSIBLE FOR PIPING, DUCT OR CONDUIT DEMOLITION. OPENINGS THROUGH FIRE-RATED CONSTRUCTION SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION OR BE FIRESTOPPED. J.REMOVE EXISTING FLOOR AND BASE MATERIALS IN ALL AREAS SCHEDULED TO RECEIVE NEW FLOOR AND BASE. REFER TO FINISH DRAWINGS OR SCHEDULES. REMOVE FLOOR AND BASE ADHESIVES AND PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISHES. MAKE DEMOLITION CLEAN AND COMPLETE IN A MANNER SUITABLE TO ACCEPT NEW FINISHES AND/OR SURFACES. K.REMOVE EXISTING WALL FINISHES ON ALL WALLS SCHEDULED TO RECEIVE NEW FINISHES. REFER TO FINISH DRAWINGS FOR LOCATIONS OF NEW FINISHES. REMOVE EXISTING WALL COVERINGS AND ADHESIVES. PREPARE WALL SURFACES AS DETAILED IN SPECIFICATIONS. 24252627293031333436 A B.6 C G.6 H J A110 3 a1 a2 A110 2 WORK AREA BC0063 DECONTAM BC0059 a3 a4 20' - 5"10' - 2"2' - 11"a5 a5 a6 ES CLOSET BC0140 DOOR NUMBER DESIGNATION WALL TYPE WALL TYPE SUFFIX A.ALL DIMENSIONS ARE TO FACE OF DRYWALL, FACE OF BLOCK OR CONCRETE, OR TO FACE OF EXISTING WALL FINISH. B.ALL NEW WALL CONSTRUCTION TO EXTEND TO DECK. XX.# XX NEW COLUMN LINE SECTION INDICATOR DETAIL INDICATORAREA OF DETAIL DETAIL NUMBER SHEET NUMBER ROOM NAME DESIGNATION ROOM NUMBER DESIGNATION PLAN NOTE DESIGNATION A101 1 SIM SIMILAR 1 A101 SIM ROOM 000 00 101ARCHITECTURAL PLAN SYMBOLS LEGEND GENERAL ARCHITECTURAL NOTES 1/8" = 1'-0"1 00- LOWER LEVEL DEMOLITION PLAN 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\JSagen\Documents\04610101-ARCH_BSALS_CENTRAL_v2016_jsagen.rvt2/23/2017 11:34:30 AMFEB. 23, 2017 A100 DEMOLITION & DIMENSION PLAN 100% CONTRACT DOCUMENTS CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT NOTES- DEMOLITION PLAN x1 DEMO CEILING COMPLETE. x2 DEMO FINISH FLOORING COMPLETE. x3 REMOVE EYEWASH AND PATCH/FINISH WALL TO MATCH EXISTING. x4 REMOVE BASE CABINET AND COUNTER COMPLETE. x5 REMOVE CART WAHSER COMPLETE. x6 DEMO AS REQUIRED FOR NEW CONSTRUCTION. x7 REMOVE WASHERS, S.S. TRIM AND BULKHEAD COMPLETE. x8 DEMO CONCRETE FLOOR AS REQURIED FOR NEW CARTWAHSER PIT. 1/8" = 1'-0"2 00- LOWER LEVEL ARCHITECTURAL PLAN NOTES- ARCHITECTURAL PLAN a1 PATCH FLOOR TO MATCH EXISTING FINISH. CONTRACTOR TO VERIFY EXTENT OF FLOOR PATCH WITH MODIFIED DRAIN LOCATIONS ON SITE. a2 NEW WALL CONSTRUCTION TO MATCH ADJACENT METAL STUD AND DRYWALL CONSTRUCTION. USE MOSITURE RESISTANT DRYWALL. WALL TO EXTEND TO DECK WITH DRYWALL ON DIRTY SIDE OF WALL. a3 EXISTING COUNTER TOP AND SINK TO REMAIN. a4 ALIGN. a5 EXTEND EXISTING METAL STUD AND DRWYALL CONSTRUCTION TO DECK. APPLY DRYWALL ON DIRTY SIDE OF WALL. a6 INSTALL NEW CONTINUOUS HINGE, STAINLESS STEEL DOOR ARMOR ON PUSH SIDE OF DOOR, AND STORE ROOM LOCK WITH BATTERY OPPERATED KEYPAD TO MATCH EXISTING SOILED UTILITY ROOM DOOR. ADD HINGE FILLER PLATES PAINTED TO MATCH DOOR FRAME COLOR. REFER TO DOOR HARDWARE SPECIFICATION. MARK DATE DESCRIPTION S CCOC OC 24252627293031333436 A B.6 C G.6 H J c1 c2 c2 c3 c4 c4 ACT - 1 REFLECTED CEILING SYMBOLS SUSPENDED LAY-IN CEILING SYSTEM RECESSED "CAN" TYPE LIGHT FIXTURE OR PENDANT CEILING MOUNTED EXIT LIGHT CUBICLE CURTAIN TRACK AND CURTAIN EMERGENCY LIGHT FIXTURE 2'x4' LIGHTING FIXTURE 2'x2' LIGHTING FIXTURE RETURN AIR GRILLE SUPPLY AIR GRILLE SUPPLY AIR GRILLE CEILING HEIGHT ABOVE FINISH FLOOR DRYWALL BULKHEAD/CEILING 1'x4' LIGHTING FIXTURE ACOUSTICAL CEILING TILE - TYPE 4' X4' SUSPENDED LAY-IN CEILING SYSTEM EXHAUST AIR GRILLE +9'-0" GENERAL ELEVATION NOTES A.ALL DIMENSIONS ARE TAKEN TO THE FACE OF FINISHED MATERIAL. B.INSTALL WOOD BLOCKING TO STUDS TO SUPPORT ALL WALL- MOUNTED CABINETRY AND EQUIPMENT AS REQUIRED. C.CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTING CABINETRY. D.ALL CASEWORK SHALL BE FINISHED IN PLASTIC LAMINATE UNLESS NOTED OTHERWISE. E.PROVIDE FILLER PANELS AT ALL LOCATIONS WHERE CABINETRY ABUTS A WALL. F.PROVIDE A 4" HIGH INTEGRAL BACK SPLASH ON ALL COUNTERS WITH RECESSED SINKS. INSTALL SIDE SPLASHES WHERE THESE COUNTERS ABUT A WALL. G.PROVIDE ADJUSTABLE SHELVING WITHIN ALL WALL AND BASE CABINETRY AS SHOWN BY DASHED LINE. H.PROVIDE 12" CLEAR INTERIOR DIMENSION ON ALL UPPER WALL CABINETS UNLESS NOTED OTHERWISE. I.CONSTRUCT GYPSUM DRYWALL BULKHEADS ABOVE UPPER CABINETRY TO BE 1" DEEPER AND LONGER THAN CABINETRY BELOW UNLESS INDICATED OTHERWISE. J.COORDINATE BULKHEAD HEIGHTS INDICATED HERE WITH THAT SHOWN ON THE REFLECTED CEILING PLAN. CONFIRM ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION. K.COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK. L.PAINTING CONTRACTOR IS TO STENCIL WALL RATING ON WALLS INDICATED AS RATED ABOVE THE CEILING ON 20'-30' INTERVALS.2' - 0"0' - 4"3' - 0"3' - 6"2' - 0"3' - 0"3' - 0" 12' - 0" e1 e2 e3e4e5 e4 e7 e8 e9 e11 e13 10' - 2"0' - 6"10' - 9"2' - 11 5/8"3' - 0 3/8"4' - 0 1/2"1' - 8 1/4"27' - 5" 30' - 7"8' - 0"e6e10 e7 e9 e12 e8 e14 e12e12 1' - 8 1/4"4' - 0 3/4"3' - 2 7/8"2' - 9 1/8"10' - 9"0' - 5 3/4"10' - 2 1/4"8' - 9"8' - 0" - WALL OPENING BEYOND+/- 6' - 8 3/4" F.V.9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\JSagen\Documents\04610101-ARCH_BSALS_CENTRAL_v2016_jsagen.rvt2/23/2017 11:34:40 AMFEB. 23, 2017 A110 REFLECTED CEILING PLAN & INTERIOR ELEVATIONS 100% CONTRACT DOCUMENTS CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT 1/8" = 1'-0"1 00- LOWER LEVEL REFLECTED CEILING PLAN NOTES- INTERIOR ELEVATION e1 19" DEEP (UNO) SOLID SURFACE (SS1 UNO) COUNTERTOP WITH SIDE AND BACK SPLASHES, AS INDICATED. e2 18" DEEP (UNO) BASE CABINET, CONFIGURE DOOR (S), DRAWER(S), AND SHELVE(S) AS INDICATED. e3 18" DEEP PLASTIC LAMINATE SINK BASE WITH REMOVABLE PANEL e4 FINISHED END PANEL e5 COUNTER SUPPORT BRACKET @ 48" O.C. MAXIMUM. e6 SAOP DISPENSER. (OFCI) e7 OPENING FOR NEW RELIANCE RACK RETURN. REFER TO STERIS DRAWINGS AND CUT SHEETS. e8 OPENING FOR 3 NEW STERIS WASHERS. REFER TO STERIS DRAWINGS AND CUT SHEETS. e9 OPENING FOR NEW STERIS CART WASHER. REFER TO STERIS DRAWINGS AND CUTSHEETS. e10 PAPER TOWEL DISPENSER. (OFCI) e11 STAINLESS STEEL WALL FNISH. e12 STAINLESS STEEL ACCESS PANEL IN NEW STAINLESS STEEL TRIM. e13 WALL PROTECTION (WP1). e14 NEW WALL CONSTRUCTION TO MATCH ADJACENT WALL CONSTRUCTION AND FINISH. 1/4" = 1'-0"3 CELAN SIDE ELEVATION NOTES- REFLECTED CEILING PLAN c1 COORDINATE CEILING TERMINATION WITH STERIS EQUIPMENT AND S.S. TRIM. c2 MODIFY EXISTING CEILING AS REQUIRED FOR NEW CONSTRUCTION. c3 NEW CLEAN ROOM ACT CEILING TO MATCH EXISTING HEIGHT. c4 STAINLESS STEEL TRIM TO EXTEND FROM TOP OF STERIS EQUIPMENT TO 6" ABOVE FINISH CEILING. 1/4" = 1'-0"2 DECONTAM SIDE ELEVATION MARK DATE DESCRIPTION 24252627293031333436 A B.6 C G.6 H J CG1 CG1 CG1 CG1 1 2 SV1 EP1 SV1 DECONTAM BC0059 a ETR ETR ETR WORK AREA BC0063 3 4 GENERAL FINISH NOTES FINISH PLAN NOTES FINISH REMARKS FINISH LEGEND BLOCK FINISH ABBREVIATIONS ACT ACOUSTICAL CEILING TILE CG CORNER GUARD EP EPOXY PAINT ETR EXISTING TO REMAIN P PAINT PL PLASTIC LAMINATE SC SEALED CONCRETE (SPEC 03300) SV SHEET VINYL VCT VINYL COMPOSITION TILE WP WALL PROTECTION ROOM NAME ROOM NUMBER REMARKS COLUMN FLOOR BASE WALL NOTE: FINISHES INDICATED IN FINISH LEGEND BLOCKS ARE GENERAL OVERALL FINISHES FOR ROOM UNLESS OTHERWISE NOTED BY NOTE, REMARK, DETAIL, AND/OR ELEVATION. A.PATTERN NAME, COLOR AND NUMBER FOR EACH MATERIAL ARE GIVEN WHENEVER POSSIBLE ON THE FINISH PLAN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING ANY DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT/DESIGNER SO THAT THE CORRECT MATERIAL IS INSTALLED. B.PAINT ALL BULKHEADS AND SOFFITS TO MATCH THE ADJACENT WALL FINISH, UNLESS NOTED OTHERWISE ON PLANS. ALL BULKHEADS, SOFFITS, AND DRYWALL CEILING SURFACES SHOULD BE FINISHED WITH THE SAME MATERIAL AND OR COLOR ON ALL FACES AS SPECIFIED, UNLESS NOTED OTHERWISE. C.PAINT ALL DRYWALL CEILING SURFACES "CEILING WHITE" TO MATCH HOSPITAL STANDARD. D.REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL CEILING FINISHES. E.ALL FLOORING MATERIAL SHALL BE CENTERED UNDER THE DOOR IN THE CLOSED POSITION. F.ALL DOOR AND WINDOW METAL TRIM ADJACENT TO NEWLY PAINTED WALLS SHALL BE PAINTED (P2) UNLESS NOTED OTHERWISE. IF ADJACENT WALLS ARE NOT BEING PAINTED, DOOR AND WINDOW METAL TRIM SHALL NOT BE PAINTED. IF WALLS ARE BEING PAINTED ON ONE SIDE OF A DOOR AND NOT THE OTHER, PAINT CORRESPONDING SIDE OF DOOR TRIM. G.ALL HOLLOW METAL DOORS ADJACENT TO NEWLY PAINTED WALLS SHALL BE PAINTED (P2) UNLESS NOTED OTHERWISE. IF ADJACENT WALLS ARE NOT BEING PAINTED, HOLLOW METAL DOORS SHALL NOT BE PAINTED. IF WALLS ARE BEING PAINTED ON ONE SIDE OF A DOOR AND NOT THE OTHER, PAINT CORRESPONDING SIDE OF DOOR. H.REFER TO THIS SHEET FOR FLOOR TRANSITION DETAILS. I.ALL VERTICAL PLASTIC LAMINATE SURFACES TO BE (PL1) UNLESS NOTED OTHERWISE. ALL HORIZONTAL SOLID SURFACE WORK SURFACES AND BACKSPLASH TO BE (SS1) UNLESS NOTED OTHERWISE. J.THERE SHALL NOT BE PAINT CONDITIONS THAT OCCUR CAUSING FINISH OR COLOR TO TERMINATE ON AN OUTSIDE CORNER UNLESS SPECIFICALLY NOTED OTHERWISE. IF THIS CONDITION OCCURS BRING IT TO THE ATTENTION OF THE DESIGNER IMMEDIATELY. K.REFER TO PROJECT MANUAL SECTION “CAST-IN-PLACE CONCRETE” FOR SPECIFICATIONS FOR SEALED CONCRETE (SC). L.ALL FLOORING TO BE INSTALLED PERPENDICULAR TO ROOM WALLS UNLESS NOTED OTHERWISE. M.DASHED IN FURNITURE TO BE OWNER FURNISHED, OWNER INSTALLED. N.PATCH AND MATCH EXISTING FINISHES AS NEEDED FOR NEW CONSTRUCTION O.PAINT ALL GRILLES, VENTS, ELECTRICAL PANELS, ACCESS PANELS, ETC. TO MATCH ADJACENT WALL UNLESS NOTED OTHERWISE. P.PROVIDE WALL PROTECTION AT MOP BASINS TO WIDTH AND OR DEPTH OF SINK AND 36” HEIGHT Q.PROVIDE JOHNSONITE LEVEL SYSTEM OR EQUAL AS NEEDED FOR SMOOTH TRANSITION BETWEEN FLOORING MATERIALS. SLOPE TO BE 1 TO 20. R.PAINT STEEL COLUMNS, BEAMS, STRUCTURE ETC. EXPOSED TO VIEW IN FINISHED AREAS (P1) UNLESS NOTED OTHERWISE. S.FINISH BEHIND FIXED EQUIPMENT SUCH AS CABINETRY, CASEWORK, CHALK AND TACK/MARKERBOARDS, LOCKERS ETC. T.USE MANUFACTURER'S RECOMMENDED COORDINATING WELD ROD COLORS FOR SHEET VINYL SEAMS. a. BASE TO BE INTEGRAL. REFER TO IF100-2 FOR DETAIL.0' - 4"WALL FINISH. REFER TO FINISH PLAN 1/8" METAL COVE CAP SHEET FLOORING INTEGRAL BASE COVE STICK BEHIND SHEET FLOORING SILICON BEAD PROVIDE TROWELABLE UNDERLAYMENT AS REQUIRED TO ALLOW FOR FLUSH AND LEVEL TRANSITION. METAL DIVIDER STRIP CONCRETE SLAB - LEVEL AS REQUIRED SVVCT 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\JSagen\Documents\04610101-ARCH_BSALS_CENTRAL_v2016_jsagen.rvt2/23/2017 11:35:07 AMFEB. 23, 2017 IF100 INTERIOR FINISH PLAN 100% CONTRACT DOCUMENTS CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT MARK DATE DESCRIPTION 1/8" = 1'-0"1 00- LOWER LEVEL FINISH PLAN INTERIORS- FINISH SPECIFICATIONS MARK: MANUFACTURER: STYLE: NUMBER: COLOR: SIZE:COMMENTS:CONTACT: EPOXY PAINT EP1 HOSPITAL STANDARD TO MATCH EXISTING WALL PAINT PAINT P2 HOSPITAL STANDARD TO MATCH EXISTING METAL DOOR AND TRIM PAINT PLASTIC LAMINATE PL1 HOSPITAL STANDARD TO MATCH EXISTING VERTICAL SURFACE PLASTIC LAMINATE HOSPITAL STANDARD SHEET VINYL SV1 ALTRO MAXIS UNITY UBI2508 MONUMENT (BEIGE)LORI SHUFFLEBARGER, GAIL FORCE ENTERPRISES, 317-442-6353, poshespionage@gmail.com SOLID SURFACE SS1 HOSPITAL STANDARD TO MATCH EXISTING SOLID SURFACE COUNTERTOP HOSPITAL STANDARD WALL PROTECTION WP1 HOSPITAL STANDARD TO MATCH EXISTING HOSPITAL STANDARD WALL PROTECTION 3" = 1'-0"2 INTEGRAL COVE BASE DETAIL 6" = 1'-0"3 FLOORING TRANSITION - RESILIENT FLOORING TO RESILIENT FLOORING 1 PATCH AND REPAIR SURROUNDING WALL, FLOORING, BASE FINISHES AS NECESSARY FOR INSTALLATION OF NEW CASEWORK. 2 PATCH VCT FLOORING AS NEEDED TO MATCH EXISTING. 3 EXTEND DECONTAM FLOORING, WALL, BASE FINISHES INTO THIS AREA. 4 INSTALL WALL PROTECTION (WP1) TO 48" A.F.F. A VP T T H FS ΔT T CO ABBREV.ABBREV.ABBREV.DESCRIPTION DESCRIPTION DESCRIPTION GENERAL HVAC AND PLUMBING ABBREVIATIONS A/E ARCHITECT AND ENGINEER AD ACCESS DOOR ADJ ADJUSTABLE OR ADJACENT AFF ABOVE FINISHED FLOOR APPROX APPROXIMATE ARCH ARCHITECT ATM ATMOSPHERE BHP BRAKE HORSEPOWER BLDG BUILDING BOT BOTTOM BTU BRITISH THERMAL UNIT BTUH BTU PER HOUR CAP CAPACITY CENTRIF CENTRIFUGAL CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CFOI CONTRACTOR FURNISHED/OWNER INSTALLED CI CAST IRON CO CLEANOUT COL COLUMN COMP COMPRESSOR CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CSP CEILING SERVICE PANEL DEG DEGREE DEPT DEPARTMENT DIA DIAMETER DISC DISCONNECT DISCH DISCHARGE DN DOWN DWG DRAWING EC ELECTRICAL CONTRACTOR ECC ENVIRONMENTAL CONTROL CONTRACTOR EER ENERGY EFFICIENCY RATING ELEC ELECTRIC ELEV ELEVATION EMER EMERGENCY ENCL ENCLOSURE ENTR ENTERING EQUIP EQUIPMENT ET EXPANSION TANK EWT ENTERING WATER TEMPERATURE EX OR EXIST EXISTING EXT EXTERIOR F DEGREES FAHRENHEIT FC FLEXIBLE CONNECTION FH FUME HOOD FIN FINISH FLA FULL LOAD AMPS FLR FLOOR FPC FIRE PROTECTION CONTRACTOR FT FEET G GAS, NATRUAL GA GAUGE GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR GH GRAVITY HOOD GPM GALLONS PER MINUTE GV GAS, NATURAL VENT GW GLASSWARE WASHER H HEIGHT HD HEAD HGT HEIGHT HOA HAND-OFF-AUTOMATIC HORZ HORIZONTAL HOSP HOSPITAL HP HORSEPOWER HR HOUR HZ HERTZ ID INSIDE DIAMETER OR DIMENSION IN INCHES INCL INCLUDE INSUL INSULATED INT INTERIOR INV INVERT I.P.S.INTERNATIONAL PIPE SIZING JT JOINT KAIC SHORT CIRCUIT RATING KEC KITCHEN EQUIPMENT CONTRACTOR KW KILOWATTS L LENGTH LBS OR #POUNDS LF LINEAR FOOT LFT LEAVING FLUID TEMPERATURE LOC LOCATION LVG LEAVING LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH 1000 BTU/HR MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MOCP MAXIMUM OVERCURRENT PROTECTION MTD MOUNTED N NORTH NA NOT APPLICABLE NC NORMALLY CLOSED OR NOISE CRITERIA NIC NOT IN CONTRACT NO NORMALLY OPEN OR NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED/CONTRACTOR INSTALLED OFOI OWNER FURNISHED/OWNER INSTALLED OPER OPERATOR OPNG OPENING ORIG ORIGINAL P PUMP, PNEUMATIC OR PRESSURE PC PLUMBING CONTRACTOR PD PRESSURE DROP POC POINT OF CONNECTION PPH POUNDS PER HOUR PPM PARTS PER MILLION PREFAB PREFABRICATED PRES PRESSURE PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PVC POLYVINYL CHLORIDE REC RECEIVER RECIRC RECIRCULATING REF REFRIGERATOR RLA RUNNING LOAD AMPS RM ROOM RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR OR SOUND ATTENUATOR SCFM STANDARD CUBIC FEET PER MINUTE SCH SCHEDULE SEC SECTION SENS SENSIBLE SF SQUARE FOOT SHT SHEET SPEC SPECIFICATIONS SQ SQUARE SQFT SQUARE FEET SRV SAFETY RELIEF VALVE SS STAINLESS STEEL STD STANDARD STR STARTER OR STRUCTURE STRUC STRUCTURAL SW SWITCH SYS SYSTEM TCC TEMPERATURE CONTROL CONTRACTOR TDH TOTAL DYNAMIC HEAD TEMP TEMPERATURE TLL TEMPERATURE LOW LIMIT TMBH TOTAL MBH TSP TOTAL STATIC PRESSURE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UVL ULTRA VIOLET LIGHT VB VACUUM BREAKER VEL VELOCITY VFC VARIABLE FREQUENCY CONTROLLER VSC VARIABLE SPEED CONTROLLER VTR VENT THROUGH ROOF W WATTS OR WIDTH W/WITH W/O WITHOUT WC WATER COLUMN WFMD WATER FLOW MEASURING DEVICE WG WATER GAUGE WGT WEIGHT WM WATER METER WP WEATHERPROOF WPD WATER PRESSURE DROP WTR WATER ELECTRICAL WIRING PNEUMATIC CONTRACTOR ENVIRONMENTAL CONTROL (NOTE: TCC & ECC ARE USED INTERCHANGEABLY) TEMPERATURE CONTROL CONTRACTOR LOCAL AREA NETWORK E OR P OR TCC ECC LAN 0-30 PSIG AIR GAUGE EC ELECTRICAL CONTRACTOR STEAM FLOW MEASUREMENT ORIFICE FACE & BY-PASS DAMPER VOLUME DAMPER (MANUAL) TEMPERATURE SENSOR VIBRATION SWITCH (ELECTRONIC) FLOW SENSOR SENSOR (BINARY) (ELECTRONIC) PRESSURE SENSOR RETURN AIR DAMPER PNEUMATIC RELAY OUTDOOR AIR DAMPER BACKDRAFT DAMPER(GRAVITY) EXHAUST AIR DAMPER FAN DISCHARGE DAMPER FAN INLET DAMPER PLATE & MASS FLOW COMPUTER FLOW METER VORTEX SHEDDING FLOW TRANSMITTER VORTEX SHEDDING AIR (PNEUMATIC) TEMPERATURE TRANSMITTER (PNEUMATIC) PRESSURE TRANSMITTER LOW LIMIT SAFETY THERMOSTAT ELECTRO-PNEUMATIC TRANSDUCER CURRENT TO PNEUMATIC TRANSDUCER MOTOR STARTER AIR FLOW MEASURING STATION ELECTRO-PNEUMATIC SWITCH DIFFERENTIAL PRESSURE SWITCH (HIGH LIMIT) (BINARY) (LOW LIMIT) (BINARY) DIFFERENTIAL PRESSURE SWITCH START/STOP SWITCH (DDC CONTROLLER) (DDC CONTROLLER) (DDC CONTROLLER) ANALOG INPUT (DDC CONTROLLER) ANALOG OUTPUT 20 PSIG MAIN CONTROL AIR THERMOSTAT (SPACE) NIGHT CYCLE THERMOSTAT OR TEMPERATURE SENSOR(SPACE) SWITCH (PNEUMATIC) HOLDING COIL HUMIDISTAT (SPACE) TEMPERATURE CONTROLLER MOTOR CONTROL CENTER FLOW CONTROLLER PRESSURE CONTROLLER (PNEUMATIC) FOR MOTOR VARIABLE FREQUENCY CONTROLLER (PNEUMATIC) PRESSURE-ELECTRIC SWITCH MANUAL SWITCH (ELECTRIC) HAND-OFF-AUTO SWITCH (ELECTRONIC) VELOCITY PRESSURE SENSORMETER SENSOR MAGNETIC INDUCTIVE FLOW OPERATOR'S WORK HUMIDITY HIGH LIMIT (ELECTRIC) TERMINAL BOX ACTUATOR SMOKE DETECTOR ALARM STATION MODEM (PNEUMATIC) HUMIDITY CONTROLLER HUMIDITY SENSOR OUTDOOR AIR VOLUME PROBE, TRANSDUCER AND MONITOR PRESSURE GAUGE CO2 SENSOR (HL) 120/60/1 BY EC DIFFERENTIAL PRESSURE SENSOR (ANALOG) CURRENT SENSOR TURBINE METER CURRENT TO PNEUMATIC TRANSDUCER DAMPER END SWITCH (BINARY) BINARY INPUT (DDC CONTROLLER) BINARY OUTPUT (DDC CONTROLLER) (DDC CONTROLLER) (DDC CONTROLLER) ANALOG OUTPUT AIR FLOW SWITCH (ELECTRONIC) HUMIDITY SENSOR (PNEUMATIC) HUMIDITY TRANSMITTER CONTROL SYMBOLS HVAC SYMBOLS EXHAUST DIFFUSER OR EXHAUST GRILLE SUPPLY DIFFUSER OR SUPPLY GRILLE (NO AIRFLOW IN SHADED REGION) RETURN DIFFUSER OR RETURN GRILLE MANUAL VOLUME DAMPER FD FIRE DAMPER WITH ACCESS DOOR SD SMOKE DAMPER WITH ACCESS DOOR F/SD FIRE/SMOKE DAMPER WITH ACCESS DOOR AUTOMATIC MOTOR OPERATED DAMPERMD BACKDRAFT DAMPERBDD AIR FLOW MEASURING STATION DUCT TURNED UP (SOLID LINES) DUCT TURNED DOWN (DASHED LINES) RETURN BRANCH DUCT TO RETURN GRILLE/DIFFUSER "RD#-CFM" DIFFUSER TAG DESIGNATION "RG#-CFM" GRILLE TAG DESIGNATION SUPPLY BRANCH DUCT TO SUPPLY GRILLE/DIFFUSER "SD#-CFM" DIFFUSER TAG DESIGNATION "SG#-CFM" GRILLE TAG DESIGNATION EXHAUST BRANCH DUCT TO EXHAUST GRILLE/DIFFUSER "ED#-CFM" DIFFUSER TAG DESIGNATION "EG#-CFM" GRILLE TAG DESIGNATION SIDEWALL SUPPLY, RETURN OR EXHAUST GRILLE SUPPLY, RETURN, OR EXHAUST SLOT DIFFUSER STAINLESS WELDED DUCTWORK PER SPECIFICATION BOOT TAP OR 45 DEGREE ENTRY FITTING R (RISE), D (DROP) ARROW IN DIRECTION OF AIR FLOW ACCESS DOOR 90 DEGREE ELBOW WITH TURNING VANES STANDARD RADIUS ELBOW WITH CENTER RADIUS EQUAL TO 1-1/2 TIMES WIDTH OF DUCT INTERNALLY LINED DUCTWORK FLAT OVAL DUCT (WIDTH X HEIGHT) ROUND DUCT RECTANGULAR DUCT (WIDTH X HEIGHT) SPIN-IN FITTING WITH MANUAL VOLUME DAMPER AND FLEXIBLE DUCT CONNECTION CONICAL FITTING SQUARE-TO-ROUND TRANSITION TYPICAL TERMINAL BOX WITH HEATING COIL, TWO WAY CONTROL VALVE, BOX DESIGNATION TYPICAL TERMINAL BOX WITH HEATING COIL, THREE WAY CONTROL VALVE, BOX DESIGNATION 90 DEGREE TEE (ROUND OR FLAT OVAL ONLY) INSULATED METAL PANEL AFMS R or D 20"X12" Ø 18" Ø 20"X12" 20"X12" WITH FLEX DUCT SECTION PLAN VIEW WITH FLEX DUCT SECTION PLAN VIEW WITH FLEX DUCT SECTION PLAN VIEW AD AD TYPICAL CHILLED BEAM (24"X48") DUCT DETECTOR OVERRIDE TIMER TB-X TB-X CS DD I/S ES ∆AP ∆P ∆P (LL)∆P EP EPT EAD FBD FDD FID FC FS HOA HTC HTE H BDD AL AFS TTT CO2 MCC STR OWS OAD VPS PR PE PC P PT RAD SD S/S TC TC T TT M TM 120/60/1 BY EC OM MDM S 120/60/1 BY EC MS TLL HH VXT VP VFC VD VS 120/60/1 BY EC VSM 20 HC H S T TN BO-X BI-X AO-X AI-X 12" Ø TTT OR OCCUPANCY SENSOROCCDISCONNECT SWITCH - NON-FUSED DISCONNECT SWITCH - FUSED SUPPLY AIR DAMPERSAD SUPPLY) UNINTERRUPTED POWERUPS HVAC DEMOLITION GENERAL NOTES A.EXISTING SYSTEMS SHOWN ARE BASED ON EXISTING DRAWINGS AND FIELD VERIFIED TO THE EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY THAT SERVICES INDICATED FOR REMOVAL DO NOT SERVE SPACES OUTSIDE THE PROJECT AREA. CONTRACTOR SHALL FIELD VERIFY THAT EXISTING SYSTEMS SHOWN ARE REPRESENTATIVE OF THE INSTALLED SYSTEMS AND REPORT MAJOR DISCREPANCIES TO ENGINEER OF RECORD. B.INACTIVE, ABANDONED SYSTEMS NOT SHOWN ARE TO BE REPORTED TO THE ENGINEER OF RECORD. C.CONTRACTOR IS TO COORDINATE ALL SERVICE INTERRUPTIONS WITH OWNER REPRESENTATIVES, MAINTENANCE STAFF, AND END-USERS. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCE NOTICE TO ALL AFFECTED PARTIES OF IMPENDING OUTAGE. D.SYSTEMS INDICATED BY DASHED LINE ARE TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE DESCRIBED BY PLAN NOTE(S). THIS INCLUDES THE REMOVAL OF EXISTING HANGERS, INSULATION, ASSOCIATED CONTROLS AND ACCESSORIES. ALL DUCTWORK AND PIPING TERMINATIONS NOT SHOWN AS BEING REUSED SHALL BE CAPPED. CONTRACTOR SHALL PATCH INSULATION DAMAGED DURING DEMOLITION AND WHERE PIPING IS SHOWN TO BE CAPPED. E.WHEN EQUIPMENT REQUIRING ELECTRICAL POWER IS REMOVED, CONTRACTOR SHALL ALSO DEMOLISH EXISTING POWER WIRING AND CONDUIT. A LICENSED ELECTRICIAN SHALL BE RESPONSIBLE FOR REMOVING ALL POWER WIRING AND CONDUIT. F.WHERE REMAINING MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK PENETRATES EXISTING WALLS OR FLOORS, THE OPENING CREATED MUST BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND FIRE RATING BY THE GENERAL CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. G.IF THE WORK OF OTHER TRADES IS CURRENTLY SUPPORTED BY WORK TO BE DEMOLISHED, CONTRACTOR SHALL FURNISH AND INSTALL NEW SUPPORTS. H.UNUSED HANGERS FOUND WITHIN THE PROJECT SCOPE AREA SHALL BE REMOVED. I.WHERE REQUIRED, PERFORM PRE-DEMOLITION SYSTEM TESTING (AIRFLOW, TEMPERATURE, ETC.) PRIOR TO BEGINNING ANY DEMOLITION. J.FOR PHASED SCOPE OF WORK, REFER TO ARCHITECTURAL PHASING PLANS AND OTHER PROJECT MANUAL REQUIREMENTS. CONTRACTOR IS TO VERIFY THE SPACES TO REMAIN ACTIVE UNDER THERMAL CONTROL AND EXHAUST SYSTEMS TO REMAIN ACTIVE TO SUPPORT THE PHASING. PROVIDE TEMPORARY SYSTEM MODIFICATIOS (BLANKOFFS, CAPS, TEMPORARY DUCT CONNECTIONS, TEMPORARY PIPE CONNECTIONS, ETC) AS REQUIRED TO SUPPORT THE PHASING. HVAC NEW GENERAL NOTES A.NEW WORK SHOWN ON DRAWINGS IS CONCEPTUAL IN NATURE. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL TRADES. CONTRACTOR SHALL PERFORM FINAL COORDINATION OF ALL TRADES AFTER CEILING REMOVAL ALLOWS FURTHER SITE INVESTIGATION ON EXISTING BUILDINGS. B.UNLESS NOTED OTHERWISE ON THE DRAWINGS, REFER TO SCHEDULES FOR DIFFUSER, GRILLE, TERMINAL BOX, AND OTHER TERMINAL EQUIPMENT RUNOUT SIZES. C.WHERE EQUIPMENT REQUIRING ACCESS MUST BE INSTALLED ABOVE GYPSUM CEILING, CONTRACTOR SHALL COORDINATE ADEQUATE ACCESS WITH ALL TRADES AND PROVIDE THE REQUIRED ACCESS PANELS. D.AIRFLOW OFFSETS NOTED ARE INTENDED TO PROVIDE INITIAL VALUES FOR THE TEST AND BALANCE CONTRACTOR. FINAL AIRFLOW OFFSETS ARE TO BE DETERMINED DURING FUNCTIONAL TESTING AND FINAL VOLUMETRIC FLOW RATES SHALL BE DOCUMENTED ON AS-BUILT DRAWINGS. E.COORDINATE WITH ALL TRADES TO PROVIDE THE REQUIRED EQUIPMENT ACCESS. REFER TO SPECIFICATION "COMMON WORK RESULTS FOR HVAC" FOR ADDITIONAL INFORMATION. F.FOR PHASED SCOPE OF WORK, REFER TO ARCHITECTURAL PHASING PLANS AND OTHER PROJECT MANUAL REQUIREMENTS. PROVIDE TEMPORARY SYSTEM MODIFICATIONS AS REQUIRED TO SUPPORT THE PHASING. G.NO PIPING SHALL PASS THROUGH OR BE LOCATED WITHIN ELECTRICAL ROOMS, ELECTRICAL CLOSETS, ELEVATOR MACHINE ROOMS, STAIRWELLS, OR ELEVATOR HOISTWAYS. VALVE AND FITTING SYMBOLS CALIBRATED BALANCE VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED NIPPLE W/CAP PIPE WITH BLIND FLANGE CONCENTRIC REDUCER ECCENTRIC REDUCER CHECK VALVE UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE TEMPERATURE CONTROL - 2-WAY MODULATING VALVE TEMPERATURE CONTROL - 2-WAY, 2-POSITION ISOLATION VALVE TEMPERATURE CONTROL - 3-WAY MODULATING VALVE TEMPERATURE CONTROL - 3-WAY, 2-POSITION ISOLATION VALVE SAFETY RELIEF VALVE STRAINER FLOW METER FLOOR DRAIN BY PC AUTOMATIC FLOW CONTROL VALVE FLOW MEASURING DEVICE MANUAL AIR RELIEF VENT AUTOMATIC AIR RELIEF VENT LUBRICATED PLUG VALVE PRESSURE REDUCING VALVE(STEAM, GAS, COMPRESSED AIR) ANGLE VALVE REFRIGERANT HOT GAS BY-PASS VALVE SHUT-OFF COCK (HYDRONICS) SOLENOID VALVE REFRIGERANT EXPANSION VALVE WATER PRESSURE REDUCING/REGULATING VALVE STEAM TRAP DIELECTRIC FITTING BETWEEN STEEL AND COPPER STRAINER (STEAM) PRESSURE AND TEMPERATURE PLUG REFRIGERANT SIGHT GLASS THERMOMETER (P=PRESS V=VAC T=TEMP) GAUGE SENSOR (T-TEMP H-HUMIDITY) FLOW SWITCH CLEAN OUT INDICATED EXPANSION LOOP (COLD SPRUNG) ANCHOR GUIDE REFRIGERANT SHUT-OFF VALVE EXPANSION JOINT DIFFERENTIAL SWITCH NC DETAIL VIEWPLAN VIEWS N0 NC N0 T CONNECTION OF NEW WORK TO EXISTING DETAIL WITH TOP LETTER INDICATING DETAIL DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON SECTION WITH TOP NUMBER INDICATING SECTION DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT SECTION IS CUT ON OR DRAWING THAT SECTION IS DRAWN ON A.GENERAL NOTE 1 FLOOR PLAN SYMBOLS PLAN NOTE THERMOSTAT H HUMIDISTAT A101 1 TYP 1 A101 TYP 1.PLAN NOTE LIST ISOLATION VALVE PM PRESSURE MONITOR (FLOOR PLAN) Co2 Co2 MONITOR (FLOOR PLAN) REDUCED PRESSURE BACKFLOW PREVENTER DOUBLE CHECK VALVE ASSEMBLY FIRE DEPARTMENT CONNECTION FIRE PROTECTION CONTROL VALVE CD BFW SV GR GS CPD HPR MPS MPR HPS LPR LPS CHWR CWR CWS PHWR CHWS HWS PHWS HWR DIRECTION OF PIPE SLOPE (DOWN) BOILER FEED WATER CONDENSATE & EQUIPMENT DRAIN GLYCOL RETURN GLYCOL SUPPLY CONDENSATE PUMP DISCHARGE STEAM VENT HIGH PRESSURE CONDENSATE RETURN HIGH PRESSURE STEAM MEDIUM PRESSURE CONDENSATE RETURN MEDIUM PRESSURE STEAM LOW PRESSURE CONDENSATE RETURN LOW PRESSURE STEAM CONDENSER WATER RETURN CONDENSER WATER SUPPLY CHILLED WATER RETURN CHILLED WATER SUPPLY PERIMETER HEATING WATER RETURN PERIMETER HEATING WATER SUPPLY HEATING WATER RETURN HEATING WATER SUPPLY HVAC PIPING SYMBOLS TC TRAPPED CONDENSATE IN TUNNEL (SYSTEM PRESSURE) BWCF BOILER WATER CHEMICAL FEED CWCF CONDENSER WATER CHEMICAL FEED ECWS EQUIPMENT COOLING WATER SUPPLY ECWR EQUIPMENT COOLING WATER RETURN HRS HEAT RECOVERY SUPPLY HRR HEAT RECOVERY RETURN RHG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION CBCWR CBCWS CHILLED BEAM CHILLED WATER RETURN CHILLED BEAM CHILLED WATER SUPPLY CBHWR CBHWS CHILLED BEAM HEATING WATER RETURN CHILLED BEAM HEATING WATER SUPPLY LINE SYMBOLS LIGHT DOT LINES INDICATE FUTURE WORK LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED ABBREV.ABBREV.ABBREV.DESCRIPTION DESCRIPTION DESCRIPTION HVAC ABBREVIATIONS NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT AC OR ACU AIR CONDITIONING UNIT OR AIR COMPRESSOR ACCU AIR COOLED CONDENSING UNIT AFCV AIR FLOW CONTROL VALVE AFMS AIR FLOW MEASURING STATION AHU AIR HANDLING UNIT APD AIR PRESSURE DROP AR AIR RECIEVER AS AIR SEPARATOR AVMS AIR VOLUME MEASURING STATION B BOILER BCU BLOWER COIL UNIT BDD BACKDRAFT DAMPER BI BACKWARD INCLINE BOD BOTTOM OF DUCT CAV CONSTANT AIR VOLUME CC COOLING COIL CCP COOLING COIL PUMP CD CONDENSATE DRAIN CH CHILLER CHW CHILLED WATER CHWP CHILLED WATER PUMP CP CONDENSATE PUMP CPD CONDENSATE PUMP DISCHARGE CUH CABINET UNIT HEATER CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY D DIFFUSER OR DAMPER DE DEAERATOR DB DECIBELS OR DRY BULB DC DUCT COIL DD DUAL DUCT DDC DIRECT DIGITAL CONTROL DEFL DEFLECTION DUC DOOR UNDER CUT EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EBH ELECTRIC BASEBOARD HEATER ECG EGG CRATE GRILLE ED EXHAUST DIFFUSER EDC ELECTRIC DUCT COIL EF EXHAUST AIR FAN EFT ENTERING FLUID TEMPERATURE EG EXHAUST GRILLE OR ETHYLENE GLYCOL EMG EXTRUDED METAL GRILLE ERP ELECTRIC RADIANT PANEL ESP EXTERNAL STATIC PRESSURE EUH ELECTRIC UNIT HEATER EXH EXHAUST F&B FACE & BYPASS F&T FLOAT AND THERMOSTATIC TRAP F/SD FIRE AND SMOKE DAMPER FCU FAN COIL UNIT FD FIRE DAMPER H HUMIDIFIER OR HUMIDITY HC HEATING COIL HCP HEATING COIL PUMP (HOT WATER) HE HEAT EXCHANGER HP HEAT PUMP HPR HIGH PRESSURE CONDENSATE RETURN HPS HIGH PRESSURE STEAM HRC HEAT RECOVERY COIL HTR HEATER HVAC HEATING, VENTILATION AND AIR CONDITIONING HW HOT WATER HWP HEATING HOT WATER PUMP HWR HEATING HOT WATER RETURN HWS HEATING HOT WATER SUPPLY HX HEAT EXCHANGER IFB INTEGRAL FACE AND BYPASS LAN LOCAL AREA NETWORK LAT LEAVING AIR TEMPERATURE LBD LINEAR BAR DIFFUSER LD LINEAR DIFFUSER LFD LAMINAR FLOW DIFFUSER LFT LEAVING FLUID TEMPERATURE LPR LOW PRESSURE CONDENSATE RETURN LPS LOW PRESSURE STEAM MAT MIXED AIR TEMPERATURE MD MOTORIZED DAMPER MECH MECHANICAL MPCR MEDIUM PRESSURE CONDENSATE RETURN MPS MEDIUM PRESSURE STEAM OA OUTSIDE AIR OAT OUTSIDE AIR TEMPERATURE PD PERFORATED DIFFUSER PE PNEUMATIC ELECTRIC PF PREFILTERS PG PROPYLENE GLYCOL PHC PREHEAT COIL PRD PRESSURE RELIEF DOOR PUH PROPELLER UNIT HEATER RA RETURN AIR OR RELIEF AIR RAD RADIATED RAT RETURN AIR TEMPERATURE R/H REHEAT RF RETURN AIR FAN RG RETURN GRILLE RH RELIEF HOOD OR RELATIVE HUMIDITY RHC REHEAT COIL RP RADIANT PANELS RPG RETURN PERFORATED GRILLE RV ROOF VENTILATOR SA SUPPLY AIR OR SOUND ATTENUATOR SB STEAM BOILER SC STEAM COIL SCC STEAM CONDENSATE COOLER SCCH SUBCOOLED CHIILER SD SUPPLY DIFFUSER OR SMOKE DAMPER SF SUPPLY AIR FAN SG SUPPLY GRILLE SMBH SENSIBLE MBH SMC SHEET METAL CONTRACTOR SP STATIC PRESSURE ST STEAM TRAP SV STEAM VENT T THERMOSTAT TB TERMINAL BOX TDV TRIPLE DUTY VALVE TLL TEMPERATURE LOW LIMIT TSP TOTAL STATIC PRESSURE UH UNIT HEATER VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (MANUAL) WB WET BULB 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM D:\Users\MWarren\Documents\04610101-MEP_BSALS_CENTRAL_v2016_mawarren.rvt2/23/2017 10:46:08 AMFEB. 23, 2017 KPM MCW KPM H001 HVAC SYMBOLS, ABBREVIATIONS AND GENERAL NOTES 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT HVAC-RELATED CODES INFORMATION CODE DESCRIPTION MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE WITH 675 IAC 18-1.6 IMPLEMENTING AMENDMENTS). ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007 WITH 675 IAC 19-4 IMPLEMENTING AMENDMENTS). MECHANICAL SYSTEM DESIGN CRITERIA: CLIMATE ZONE 5A. EQUIPMENT AND SYSTEM CONTROL DESCRIPTION: SEE HPE SHEET. FAN MOTOR HORSEPOWER AND CONTROLS: SEE HVAC SCHEDULE SHEETS. DUCT SEALING AND DUCT AND PIPING INSULATION INFORMATION: SEE HVAC SPECIFICATION 230700. FUEL GAS CODE 2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE WITH 675 IAC 25-3 IMPLEMENTING AMENDMENTS). DEPARTMENT OF HEALTH FACILITY LICENSED AS: ACUTE CARE HOSPITAL PER 410 IAC 15-1.5-8. 2001 EDITION OF THE GUIDELINE FOR CONSTRUCTION AND EQUIPMENT OF HOSPITAL AND MEDICAL FACILITIES. CHAPTER 7 GENERAL HOSPITAL, 7.31 MECHANICAL STANDARDS APPLIES. MARK DATE DESCRIPTION A 3 2 1 2 3 1 B B 3 4 2 1 3 A 1 1 1 SEISMIC HAZARD LEVEL B SEISMIC HAZARD LEVEL A SEISMIC HAZARD LEVEL C ISOLATOR TYPES: 1. PAD, RUBBER LONGITUDINAL ANGLE 1-1/2" MIN. FLAT WASHER VERTICAL, DIAGONAL, OR REFER TO EQUIPMENT SPECIFICATION SECTIONS WHERE BASE IS PROVIDED BY EQUIPMENT MANUFACTURER AND NO ADDITIONAL BASE IS SEISMICALLY RESTRAINED EQUIPMENT SHALL BE LOCATED ON CONCRETE EQUIPMENT PADS (UNLESS NOTED OTHERWISE. SEE DETAIL) AND ANCHORED WITH SUFFICIENT SIZE AND NUMBER ANCHORS TO MEET CALCULATED FORCES DERIVED FROM SPECIFICATION SECTIONS. MANUFACTURER SHALL SELECT SEISMIC RESTRAINT EITHER INTEGRAL WITH VIBRATION ISOLATION OR WITH SEPARATE HARDWARE PER SPECIFICATION SECTIONS UNLESS A SPECIFIC TYPE IS IDENTIFIED ON THIS SCHEDULE. ELEVATION FROM GRADE SHALL BE CONSIDERED NOT LESS THAN ZERO FOR SEISMIC CALCULATIONS PER APPLICABLE BUILDING CODES. REFER TO SPECIFICATION SECTION FOR DEFINITION OF TYPES OF BASES, ISOLATORS, AND RESTRAINTS. 5. THRUST RESTRAINT 3. SPRING FLOOR ISOLATOR OR HANGER 4. RESTRAINED SPRING ISOLATOR 2. RUBBER FLOOR ISOLATOR OR HANGER AT CENTER OF RIBS EXPANSION ANCHORS2'-8" MAX. TO STRUCTURALPROVIDE 3-1/2" HEIGHT OF CURB UNLESS INDICATED OTHERWISE ON THE DRAWINGS. REINFORCING REINFORCING 3/4" CHAMFER EDGES STRUCTURAL FLOOR SLAB NOTE: O.C.E.W. = ON CENTER EACH WAY. OTHERWISE ON THE DRAWINGS. FINISH CURB SAME AS FLOOR FINISH. STRUCTURAL FLOOR. BONDING AGENT SHALL BE SBR LATEX AS MANUFACTURED BY THE CURB WIDTH TO BE A MINIMUM OF 2" LARGER THAN SIZE OF EQUIPMENT (1" MINIMUM EACH SIDE OF EQUIPMENT TO EDGE OF CURB). PROVIDE A 4" WIDTH MINIMUM UNLESS INDICATED EUCLID CHEMICAL COMPANY OR EQUAL. PREPARE SURFACES, MIX, APPLY BONDING COAT AND CURE PER MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. PROVIDE BONDING AGENT TO 100% OF THE CONTACT AREA BETWEEN THE CONCRETE CURB AND NOTES: CONCRETE CURB 41 TO 100 101 TO 200 201 TO 400 2AREA (FT ) UP TO 40 AREA (FT )2 UP TO 40 201 TO 400 101 TO 200 41 TO 100 101 TO 200 201 TO 400 2-#4 CONTINUOUS WITH 90 DEGREE BEND AT CORNERS EQ. EQ. MAX. LOAD (LB.) 15,000 25,000 50,000 8,000 MAX. LOAD (LB.) 8,000 25,000 50,000 15,000 25,000 50,000 WHEN A COMBINATION OF DUCTS IS USED IN LIEU OF ONE DUCT, AT LEAST 2 SIDES OF EACH DUCT MUST BE CONNECTED TO VERTICAL OR HORIZONTAL ANGLES AND THE COMBINED WEIGHT SHALL NOT SEE SEISMIC RESTRAINT MANUAL FOR VERTICAL HANGERS, DIAGONAL AND HORIZONTAL BRACES, BOLT EXCEED THAT GIVEN IN THE TABLE (ADD HORIZONTAL ANGLES IF REQUIRED). SIZE, CONNECTION TO SUPPORTING STRUCTURAL MEMBER, AND SPACING OF BRACING. NOTES: 2. 1. BRACE ANGLE LARGER THAN OUTSIDE ADD PIPE SLEEVE THAT HAS AN INSIDE DIAMETER 1/4"± EQUAL SUPPORTING MEMBER1"TYP. (4) SIDES1"BRACE HORIZONTAL C OF ANGLES C OF BOLTS=L L DUCT SIZE VERTICAL HANGERS HORIZONTAL BRACE 1/2" CLEAR MAX. PER SEISMIC RESTRAINT MANUAL. SELF-TAPPING SHEET METAL SCREWS BRACE 1 2 MAX 1 1 MIN 2 MAX 1 MIN TRANSVERSE STRUCTURAL MEMBER CONNECTION TO SUPPORTING ONE EACH SIDE OF LONGITUDINAL BRACE DUCT SIZES, CONNECTION TO SUPPORTING STRUCTURE, AND SPACING OF BRACES. 1. SEE SEISMIC RESTRAINT MANUAL FOR VERTICAL HANGERS, DIAGONAL BRACES, BOLT NOTES: TRANSVERSE BRACE CONNECTION TYPE A THRU D PIPE HANGER ROD CLIP 1 MIN 2 MAX 1 DIAMETER OF BOLT PIPE HANGER ROD PER TABLE LENGTH PER TABLES IN GREATER THAN MAXIMUM SCHEDULE WHEN "L" IS ADD VERTICAL HANGER FROM SEISMIC RESTRAINT MANUAL. OR HARDCORK) CONCRETE (LT. WT.DUCT SIZE1" EQUAL MACHINE BOLT AT END OF THE ANGLE LUG P TYPE A THRU H HANGER ANGLE LUG P STEEL BEAM MACHINE BOLT AT END OF THE BRACE L MACHINE BOLT SEE SCHEDULE TYPE C, D, & E G G C. CONCRETE INERTIA BASE D. CURB-MOUNTED BASE BASE TYPES: REQUIRED TO BE PROVIDED. N/A: NOT APPLICABLE. N/R: NOT REQUIRED. A. NO ADDITIONAL BASE REQUIRED, ISOLATORS ATTACHED DIRECTLY TO EQUIPMENT B. STRUCTURAL STEEL RAILS OR BASE 4. 6. 7. 5. 1. 3. 2."L" (6'-0" MAX.)TO SUPPORTING STRUCTUREGENERAL NOTES: ANCHORS FROM MANUFACTURER'S WRITTEN LITERATURE. MINIMUM OF 6" FROM EDGE OF PAD. VERIFY EDGE DISTANCE REQUIREMENTS FOR ACTUAL (4" MINIMUM EACH SIDE OF EQUIPMENT TO EDGE OF PAD) WITH EQUIPMENT ANCHORS A PAD SIZE TO BE A MINIMUM OF 8" LARGER THAN SIZE OF EQUIPMENT EACH DIRECTION PROVIDE 3-1/2" HEIGHT OF EQUIPMENT PAD UNLESS INDICATED OTHERWISE ON THE DRAWINGS. OF SEISMIC HAZARD LEVEL FOR EACH FLOOR OF THE BUILDING. SEE SPECIFICATIONS SECTION 15071, 210548, 220548, 230548, OR 260548 FOR DEFINITION EQUIPMENT PAD 3/4" CHAMFER EDGES STRUCTURAL FLOOR REINFORCING 6 X 6 W2.9XW2.9 #3 ALONG PERIMETER #3 ALONG PERIMETER AREA (FT )2 UP TO 40 41 TO 100 NOTES: CONCRETE MAX. LOAD (LB.) 8,000 15,000 REINFORCING (SEE TABLES) EQ. EQ. CABLE BRACING. SEE DETAILS IN SEISMIC RESTRAINT MANUAL. 1/4" MIN. ROD AND VERTICAL HANGER SIZES, CONNECTION TO SUPPORTING STRUCTURE, AND SPACING OF BRACES. 1. SEE SEISMIC RESTRAINT MANUAL FOR VERTICAL HANGERS, DIAGONAL BRACES, BOLT STRUCTURAL MEMBER CONNECTION TO SUPPORTING NOTES: EXPANSION ANCHORS SHOWN HERE FOR EXAMPLE LP IS GREATER THAN MAXIMUM LENGTH PER TABLES ADD VERTICAL HANGER FROM SCHEDULE WHEN "L" IN SEISMIC RESTRAINT MANUAL. LONGITUDINAL CABLE BRACE WASHER TO COVER WELD HEAVY PIPE CLAMP STRUCTURE"L" (6'-0" MAX.)TO SUPPORTINGWELDED BEAM ATTACHMENT 1-1/2" MIN. TYPICAL NOTES: SEE THE SEISMIC RESTRAINT MANUAL FOR INSTRUCTIONS FOR BRACING INDIVIDUALLY SUPPORTED PIPE. TYPE A THRU H STEEL BEAM PROVIDE FLEXIBILITY IN JOINTS WHERE PIPES PASS THROUGH BUILDING SEISMIC JOINTS OR WHERE RIGIDLY SUPPORTED PIPES CONNECT TO EQUIPMENT WITH VIBRATION ISOLATORS. BRANCH LINES MAY NOT BE USED TO BRACE MAIN LINES. A RIGID PIPING SYSTEM SHALL NOT BE BRACED TO DISSIMILAR PARTS OF THE BUILDING OR TO TWO DISSIMILAR BUILDING SYSTEMS THAT MAY RESPOND DIFFERENTLY DURING AN EARTHQUAKE. GENERAL REQUIREMENTS FOR DUCTWORK EACH SIDE OF A CHANGE IN DIRECTION OF 90° OR MORE. RISER JOINTS SHALL BE BRACED OR STABILIZED BETWEEN FLOORS. STORIES HIGH, ALL RISERS SHALL BE ENGINEERED INDIVIDUALLY. VERTICAL RISERS SHALL BE LATERALLY SUPPORTED WITH A RISER CLAMP AT EACH FLOOR. FOR BUILDINGS GREATER THAN SIX CAST IRON PIPE OF ALL TYPES AND ANY OTHER PIPE JOINED WITH A SHIELD AND CLAMP ASSEMBLY SHALL BE BRACED ON "T" - INDICATES TRANSVERSE BRACING - 1 SOLID BRACE OR 2 OPPOSING CABLES "L" - INDICATES LONGITUDINAL BRACING - 1 SOLID BRACE OR 2 OPPOSING CABLES. PROVIDE TRANSVERSE VERTICAL SUPPORT TYPICAL TRANSVERSE BRACE. PROVIDE SOLID BLOCKING AROUND DUCT PENETRATIONS AT ALL STUD WALL CONSTRUCTION. DUCTS ARE LESS THAN OR EQUAL TO THE MAXIMUM WEIGHT AND DIMENSIONS OF THE DUCT FOR WHICH BRACING DETAILS WALLS, INCLUDING GYPSUM BOARD NONBEARING PARTITIONS, WHICH HAVE DUCTS RUNNING THROUGH THEM MAY REPLACE A A GROUP OF DUCTS MAY BE COMBINED IN A LARGER FRAME SO THAT THE COMBINED WEIGHTS AND DIMENSIONS OF THE UNBRACED DUCTS SHALL BE INSTALLED WITH A 6" MINIMUM CLEARANCE TO VERTICAL CEILING HANGER WIRES. SMACNA DUCT CONSTRUCTION STANDARDS. ENDS IF THE DUCT IS LESS THAN THE SPECIFIED INTERVAL. TRANSVERSE BRACING SHALL BE INSTALLED AT EACH DUCT TURN INTERSECTION OF THE DUCTS AND IF THE BRACING IS SIZED FOR THE LARGER DUCT. DUCT JOINTS MUST CONFORM TO SECTION CONNECTED PERPENDICULAR TO IT IF THE BRACING IS INSTALLED WITHIN TWO TIMES THE DUCT WIDTH OF THE BRACE PER DUCT RUN. TRANSVERSE BRACING FOR ONE DUCT SECTION MAY ALSO ACT AS LONGITUDINAL BRACING FOR A DUCT LONGITUDINAL BRACING SHALL OCCUR AT THE INTERVAL SPECIFIED IN SEISMIC RESTRAINT MANUAL TABLES WITH AT LEAST ONE TRANSVERSE BRACING SHALL OCCUR AT THE INTERVAL SPECIFIED IN THE SEISMIC RESTRAINT MANUAL TABLES OR AT BOTH AND AT EACH END OF A DUCT RUN, WITH A MINIMUM OF ONE BRACE AT EACH END. DETAILS IN ACCORDANCE WITH SPECIFICATION. CONTRACTOR SHALL INDICATE ALL BRACING REQUIRED ON SHEET METAL SHOP DRAWINGS AND ALSO SUBMIT ALL APPLICABLE BRACE ALL DUCTWORK AS SPECIFIED. BRACE FLAT OVAL DUCTS IN THE SAME MANNER AS RECTANGULAR DUCTS. FILL ON CONCRETE STEEL DECK RIBS TO SPAN ANGLE IF REQUIRED BETWEEN LENGTHEN TYPE F, G, & H MACHINE BOLT AT END OF THE BRACE BRACE 12 DIA. MIN. EXPANSION ANCHOR. SEE SEISMIC RESTRAINT MANUAL. T BRACE AT LAST L 4. 5. 6. 7. ARE SELECTED. 9. 10. 12. 11. 13. 2. 3. 1. MAXIMUM SPACING FOR LONGITUDINAL BRACES TRANSVERSE BRACES MAXIMUM SPACING FOR TYPICAL T T T < 48" FOR DUCTS. BRACE FOR RUN "B" AND "TB" AS LONGITUDINAL BRACE FOR RUN "A" WHEN "D" IS < 24" FOR PIPES AND "TA" CAN BE USED AS LONGITUDINAL RUN "B"L TB D T TARUN "A"DPIPES ASTM A120 OR A53. REQUIRED FOR THE SEISMIC LOADS. ONLY TO REMOVE EXCESSIVE SLACK. SPECIFIED EXPANSION ANCHORS. DO NOT WELD TO GALVANIZED STEEL. MINIMUM Fy = 33 KSI AND A MINIMUM Fu = 38 KSI. GENERAL REQUIREMENTS FOR PIPING AND CONDUIT INDICATED BY THE SCHEDULES AND DETAILS IN THE SEISMIC RESTRAINT MANUAL. OF PIPING, DUCTWORK AND CONDUIT GENERAL NOTES FOR SEISMIC RESTRAINTS FOR DETERMINING THE APPLICATION OF SEISMIC RESTRAINTS TO THIS CONSTRUCTION. BRACE PIPING AND CONDUIT AS SPECIFIED IN SPECIFICATION SECTIONS. FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" OF THE AMERICAN IRON AND STEEL INSTITUTE WITH A PROPRIETARY CONNECTORS MAY BE USED WHERE THEIR RESEARCH REPORT APPROVED VALUES ARE GREATER THAN THOSE WELDING SHALL CONFORM TO AWSD1.1 AND SHALL USE EITHER THE SHIELDED OR SUBMERGED ARC METHODS. UTILIZE E70 REPLACE EXPANSION ANCHORS WHERE THE APPROVED LOADS ARE EQUAL TO OR GREATER THAN THE VALUES FOR THE THE SHEAR AND TENSION CAPACITIES LISTED IN THE SEISMIC RESTRAINT MANUAL. CAST-IN-PLACE CONCRETE INSERTS MAY EXPANSION ANCHORS SHALL HAVE LOCAL GOVERNING JURISDICTION-APPROVED VALUES EQUAL TO OR GREATER THAN BOTH BOLTS SHALL CONFORM TO ASTM A307. BOLT HOLES SHALL BE 1/16" LARGER THAN THE BOLT DIAMETER UNLESS NOTED USE EITHER CABLE OR SOLID BRACING FOR ALL SITUATIONS. DO NOT MIX BRACING TYPES IN THE SAME DIRECTION. SHALL BE ZINC-COATED TO A MINIMUM OF 0.4 OUNCES/SQUARE FOOT OR STAINLESS STEEL PER ASTM A304. TIGHTEN CABLE CABLES SHALL BE WIRE-CORE WITH A MINIMUM BREAKING STRENGTH NOTED IN THE SEISMIC RESTRAINT MANUAL. CABLE HOT-ROLLED SHAPES AND PLATES SHALL CONFORM TO ASTM A36. PIPES USED AS BRACES SHALL BE STANDARD STEEL ANY LOCATION BE LESS THAN 95 PERCENT OF THE STANDARD SHEET METAL GAGES. THE THICKNESS MAY BE LESS AT BENDS THE UNCOATED MINIMUM STEEL THICKNESS OF THE COLD-FORMED PRODUCT AS DELIVERED TO THE JOB SITE SHALL NOT AT BE PROPERLY SIZED PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN REGARDS TO EMBEDMENT, EDGE DISTANCE, AND SPACING. SEISMIC RESTRAINTS REQUIRE SEISMIC RATED EXPANSION ANCHORS PER SPECIFICATION SECTION. EXPANSION ANCHORS SHALL THE LATEST EDITION OF THE SEISMIC RESTRAINT MANUAL DURING CONSTRUCTION RATHER THOSE SHOWN ON THIS SHEET. CONTRACTOR'S RESPONSIBILITY TO PROPERLY APPLY THE SEISMIC RESTRAINT MANUAL. UTILIZE THE DETAILS AND TABLES FROM SHOWN HERE DO NOT NECESSARILY INCLUDE ALL OF THOSE WHICH WILL BE REQUIRED FOR THIS CONSTRUCTION. IT IS THE SAMPLES OF DETAILS FROM THE SEISMIC RESTRAINT MANUAL FOR TYPICAL LOCATIONS AND TYPICAL STRUCTURES. THE DETAILS SEISMIC RESTRAINT MANUAL FOR ALTERNATE ALLOWABLE CONNECTIONS. THE TYPICAL DETAILS SHOWN ARE REPRESENTATIVE THESE CONSTRUCTION DETAILS ARE REPRODUCED FROM THE SMACNA SEISMIC RESTRAINT MANUAL. REFER TO THE SMACNA THESE DETAILS DO NOT APPLY TO THE ORDINARY SUPPORTS REQUIRED FOR GRAVITY LOADS, THESE ARE ADDITIONAL RESTRAINTS SEISMIC RESTRAINTS ARE REQUIRED FOR PIPING, DUCTWORK, AND CONDUIT. SPECIFICATION SECTIONS PROVIDE THE CRITERIA GENERAL REQUIREMENTS FOR CONNECTIONS TO STRUCTURE COLD-FORMED ANGLES SHALL CONFORM TO THE MATERIAL AND IDENTIFICATION REQUIREMENTS OF THE LATEST "SPECIFICATIONS ACCORDANCE WITH SPECIFICATION SECTIONS. CONTRACTOR SHALL INDICATE ALL BRACING REQUIRED ON SUBMITTAL DRAWINGS AND ALSO SUBMIT ALL APPLICABLE DETAILS IN SIZE CONNECTED PERPENDICULAR TO IT IF THE BRACING IS INSTALLED WITHIN 24" OF THE ELBOW OR TEE AND AS LONG AS PIPES ON TRAPEZE HANGERS WILL BE BRACED AS SHOWN IN THE SEISMIC RESTRAINT MANUAL WITH THE SAME REQUIREMENTS THE BRACE IS SIZED AS A LONGITUDINAL BRACE. AND EXCEPTIONS AS SINGLE PIPES. TRANSVERSE BRACING FOR ONE PIPE SECTION MAY ALSO ACT AS LONGITUDINAL BRACING FOR A PIPE SECTION OF THE SAME EXCEPT THAT TRANSVERSE BRACING SHALL BE ONE HALF THE SPACING SHOWN IN THE SEISMIC RESTRAINT MANUAL. FOR ALL GAS PIPING, AS SPECIFIED IN THE SPECIFICATIONS. THE BRACING DETAILS, SCHEDULES AND NOTES MAY BE USED, LONGITUDINAL BRACE. THE LONGITUDINAL BRACES AND CONNECTIONS MUST BE CAPABLE OR RESISTING THE ADDITIONAL RESTRAINT MANUAL. IN PIPES WHERE THERMAL EXPANSION IS A CONSIDERATION (PIPES ON ROLLER HANGERS, PIPING LONGITUDINAL BRACING SHALL BE AT 80 FEET MAXIMUM EXCEPT WHERE A LESSER SPACING IS INDICATED IN THE SEISMIC ALL RUNS WILL HAVE A MINIMUM OF TWO TRANSVERSE BRACES AND ONE LONGITUDINAL BRACE. A RUN IS DEFINED AS A TRANSVERSE BRACING SHALL BE AT 40 FEET MAXIMUM EXCEPT WHERE A LESSER SPACING IS INDICATED IN THE SEISMIC SHOWN WITH AN ANCHOR FOR THERMAL EXPANSION, AND PIPING WITH AN EXPANSION LOOP), AN ANCHOR POINT MAY BE USED AS THE SPECIFIED LONGITUDINAL BRACE PROVIDED THAT IT HAS A CAPACITY EQUAL TO OR GREATER THAN A LENGTH OF PIPE OR DUCT WITHOUT ANY CHANGE IN DIRECTION EXCEPT AS ALLOWED BY OFFSETS. FORCE INDUCED BY EXPANSION AND CONTRACTION. 2. 3. 4. 5. 7. 6. 8. RESTRAINT MANUAL. 4. 5. 6. 7. 8. 9. 10. 1. ELECTRODES. OTHERWISE. 1. 2. 3. 3. 4. AFTER COLD-FORMING. 1. 2. E. NO BASE, ANCHORAGE ATTACHED DIRECTLY TO EQUIPMENT FAN HAS INTERNAL ISOLATION PROVIDED BY FAN MANUFACTURER. SCHEDULE NOTES: SLAB ON GRADE OR MANUAL. 2. CABLE BRACING IS ALSO ACCEPTABLE IN ACCORDANCE WITH THE SEISMIC RESTRAINT ANGLE (LLH) SEE SEISMIC RESTRAINT MANUAL FOR SIZE, BEND VERTICAL LEG AS REQUIRED FOR DIAGONAL BRACE. 1" TYPICAL BONDING AGENT SAME SIDE OF CURBED PERIMETER. SEALANT CONTINUOUS. APPLY TO STRUCTURAL FLOOR. BONDING AGENT SHALL BE SBR LATEX AS MANUFACTURED BY THE EUCLID CHEMICAL COMPANY OR EQUAL. PREPARE SURFACES, MIX, APPLY BONDING COAT AND CURE PER MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. PROVIDE BONDING AGENT TO 100% OF THE CONTACT AREA BETWEEN THE EQUIPMENT PAD AND METAL DECK BONDING AGENT 2"PERIMETER BAR CENTER OF #3 @ 12" O.C.E.W. #4 ALONG PERIMETER #4 @ 12" O.C.E.W. #4 ALONG PERIMETER #4 @ 12" O.C.E.W. #3 ALONG PERIMETER #3 ALONG PERIMETER #3 @ 12" O.C.E.W. #4 ALONG PERIMETER #4 @ 12" O.C.E.W. #4 ALONG PERIMETER #4 @ 12" O.C.E.W. #3 ALONG PERIMETER #3 @ 12" O.C.E.W. #4 ALONG PERIMETER #4 @ 12" O.C.E.W. #5 ALONG PERIMETER #5 @ 12" O.C.E.W. #5 ALONG PERIMETER #5 @ 12" O.C.E.W. #3 @ 12" O.C.E.W. 5 EQUPMENT PAD DETAIL NO SCALE L 1 4 2 7 CONCRETE CURB DETAIL NO SCALE 6 TYPICAL SIDE BRACING FOR RECTANGULAR DUCTS NO SCALE 3 TYPICAL CONNECTIONS TO STRUCTURE NO SCALE2 TYPICAL TRANSVERSE BRACING FOR PIPES AND CONDUIT NO SCALE 4 TYPICAL LOCATIONS OF BRACING NO SCALE 1 TYPICAL LONGITUDINAL BRACING FOR PIPES AND CONDUIT NO SCALE5 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM D:\Users\MWarren\Documents\04610101-MEP_BSALS_CENTRAL_v2016_mawarren.rvt2/23/2017 10:46:26 AMFEB. 23, 2017 KPM MCW KPM HPE1 SEISMIC DETAILS AND SCHEDULES 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT VIBRATION ISOLATION AND EQUIPMENT RESTRAINT SCHEDULE EQUIPMENT TAG LOCATION ELEV FROM GRADE (FT.) BASE TYPE ISOLATOR TYPE MIN. STATIC DEFLECTION (IN.) RESTRAINT REQUIRED NOTES EF-18 ROOF 50' - 0" N/A N/A N/A YES 7 EF-61 ROOF 15' - 0" N/A N/A N/A YES 7 MARK DATE DESCRIPTION TO LAN AND OWS 24 /60 BY ECC E SUPPLY AIR HWR HWS E E S CONTROLLER E DDC S LAN BY ECC TERMINAL BOX HEATING COIL FROM AHU SEQUENCE OF OPERATION - CAV BOXES: 1. TERMINAL BOX CONTROLLER SHALL RESPOND TO CHANGES IN SPACE TEMPERATURE BY MODULATING HEATING COIL VALVE SUPPLY AIR VOLUME TO BE MAINTAINED AT A CONSTANT VALUE REGARDLESS OF CHANGES IN SUPPLY DUCT STATIC PRESSURE THROUGH CONTROL OF DAMPER ACTUACTOR. THROUGH LAN TO OPERATORS WORK STATION IT SHALL BE POSSIBLE TO READ AND ADJUST SPACE SPACE TEMPERATURE AND SUPPLY AIR VOLUMES (MAXIMUM AND MINIMUMS), ECC TO NOTE THAT ALL ACTUACTORS ARE FURNISHED BY ECC AND INSTALLED BY BOX MANUFACTURER ON DDC CONTROLLED BOXES. PLAN NOTES: FURNISHED, INSTALLED, WIRED AND COMMISSIONED BY ECC. INTEGRAL WITH TERMINAL BOX. FURNISHED AND COMMISSIONED BY ECC; INSTALLED BY TERMINAL BOX SUPPLIER. FURNISHED BY ECC; INSTALLED BY MC. AIR VOLUME SENSOR TO RECALIBRATE AUTOMATICALLY WITH A SCHEDULE APPROVED BY OWNER. DISCONNECT BY BOX MFR. FAIL IN LAST POSITION. E T 1 1 3 2 5 3 5 FS M T 74 1 2 3 4 5 6 7 6 EXHAUST FAN EF-61 EXHAUST AIR STR BO-1 BI-1 POWER BY E.C. PLAN NOTES 1. DAMPER ACTUATOR SHALL BE ABLE TO FULLY OPEN/CLOSE WITHIN 10 SECONDS. DAMPER BY ECC. 2. DAMPER INTEGRAL TO CART WASH BY MANUFACTURER. 3. WIRE POINTS BACK TO NEAREST DDC PANEL. SEQUENCE OF OPERATION: 1. EXHAUST FANS EF-18 AND EF-61 RUN CONTINUOUSLY. 2. EXHAUST FOR EF-61 IS NORMALLY PULLED FROM CART WASH CONNECTION (ED-1 OPEN) AND SERVICE SPACE DAMPER (ED-2) IS FULLY CLOSED. 3. ON INPUT SIGNAL FROM CART WASHER, ED-2 OPENS TO PULL EXHAUST FROM SERVICE AREA WHILE ED-1 IS CLOSED BY CART WASH MANUFACTURER. COORDINATE FINAL DAMPER POSITION WITH EQUIPMENT PROVIDER TO ENSURE ANY MINIMUM FLOW REQUIREMENTS. ED-1 2 INSTRUMENT WASHER EXHAUST (60 CFM) INSTRUMENT WASHER EXHAUST (60 CFM) INSTRUMENT WASHER EXHAUST (60 CFM) CART WASHER EXHAUST (1,000/0 CFM) CART WASH PANELBI-3 CART WASHER SERVICE EXHAUST (0/1,000 CFM) AO-1ED-2 1 3 EXHAUST FAN EF-18 EXHAUST AIR STR BO-2 BI-2 POWER BY E.C. DECON (+/-2,000 CFM) 120/60/1 BY E.C. DISCONNECT BY EC EACH CIRCUIT TO FEED UP TO FIVE TERMINAL BOXES (100VA/CIRCUIT) WIRED BY ECC TRANSFORMER PANEL (120/24) 500 VA TRANSFORMER COMPLETE WITH ON-OFF SWITCHES AND CIRCUIT BREAKERS PER CIRCUIT (5). NOTES TRANSFORMER PANELS TO BE LOCATED IN ELECTRICAL AND MECHANICAL ROOMS AS SHOWN ON PLANS. - LOW VOLTAGE WIRING SHALL NOT EXCEED 150' FROM TRANSFORMER TO CONTROLLER. - MOUNTING AND FIELD WIRING BY ECC; POWER WIRING BY EC (FUNCTIONAL DEVICES PSH500A OR EQUAL). 24 VOLT WIRING TO TERMINAL BOXES TO MEET ALL LOCAL, STATE AND NATIONAL CODES AND STANDARDS IN ADDITION TO BSA SPECIFICATIONS. TR 1 1 2 FROM EXHAUST FAN OUTER METAL DUCT 1/2-INCH TALL Z-CHANNEL SPACED 90° APART RETAINING CLIPS TO SUPPORT OUTER DUCT D+1" D 4D 2D3 3 4 2 2 4 PLAN NOTES SEE FAN DETAIL FOR "D" DIMENSION. WELDED TABS OR OTHER SUITABLE DETAILS ARE APPROPRIATE AS LONG AS INTENT OF ALLOWING RAIN TO DRAIN DOWN BETWEEN INNER AND OUTER DUCT IS MET. DO NOT EXCEED 8' STACK HEIGHT.. STACK SHEETMETAL TO BE 16 GAUGE GALVANIZED MINIMUM. 1 2 3 4 DISCHARGE DUCT FULL SIZE OF TERMINAL BOX COIL UNLESS NOTED OTHERWISE DO NOT CONNECT DIFFUSERS TO END OF DISCHARGE DUCT DISCHARGE DUCT TO EXTEND 9" BEYOND LAST DIFFUSER TAKEOFF REFER TO DRAWINGS FOR RUNOUT SIZE (TYP.) PROVIDE TRANSITION DUCT AS REQUIRED HEATING COIL TERMINAL BOX SPIN-IN TAKEOFF WITH VOLUME DAMPER WITH INSULATION STANDOFF (TYP.)AIRFLOWMAIN BRANCH TAP 45° BOOTTAPSQUARESQUARE SQUARE ROUND BELLMOUTH 45° LATERALROUNDROUND 5 7 1 8 9 10 4 6 3 7 2 11 NOTES A MINIMUM OF THREE (3) DUCT DIAMETERS (MAXIMUM OF 3'-0") OF STRAIGHT HARD METAL DUCT SHALL BE PROVIDED DIRECTLY UPSTREAM OF TERMINAL BOX INLET AFTER TRANSITION TO TERMINAL BOX INLET SIZE. MAINTAIN A MINIMUM OF 24" CLEARANCE FOR SERVICE, CONTROLLER, AND HEATING COIL VALVING. PROVIDE 36" MINIMUM CLEARANCE WHERE VOLTAGE EXCEEDS 24V. COORDINATE ACCESS CLEARANCE FROM UNIT THROUGH CEILING BELOW WITH ALL TRADES. OPTIONAL FLEXIBLE DUCT CONNECTION TO THE TERMINAL BOX. HARD DUCT IS PERFECTLY ACCEPTABLE. FLEXIBLE DUCT SHALL NOT EXCEED ONE (1) FOOT IN LENGTH. FLEXIBLE DUCT SHALL BE INSTALLED STRAIGHT WITH NO OFFSETS. REFER TO DRAWINGS FOR RUNOUT SIZES. RUNOUT SIZE IS SAME AS TERMINAL BOX INLET SIZE UNLESS NOTED OTHERWISE. DUCT SIZE AFTER TRANSITION IS SAME SIZE AS SCHEDULED TERMINAL BOX INLET SIZE AS MODIFIED BY COMPLETED SUBMITTALS. TRANSITION AS REQUIRED IF RUNOUT SIZE DIFFERS FROM TERMINAL BOX INLET SIZE. TIE-WRAP CONNECT FLEX DUCT HELICAL COIL TO ROUND METAL DUCTWORK. PULL FLEX DUCT VAPOR BARRIER OVER LOWER TIE-WRAP AND INSTALL SECOND TIE-WRAP OVER THE VAPOR BARRIER. INSULATE METAL DUCT OVER TOP OF SECOND TIE-WRAP AND INSTALL INSULATOR'S TAPE ON EDGES. INSULATE ALL EXPOSED METAL AT TERMINAL BOX INLET. INSULATE AROUND FLOW SENSORS. INSULATE ALL EXPOSED METAL AT COIL. INSULATE RETURN BENDS. SEAL CLEAT JOINTS. DUCTWORK INSULATION SHALL OVERLAP THE INTERNALLY INSULATED TERMINAL UNIT BY TWO INCHES. INSULATE COIL PIPING BETWEEN CONTROL VALVE AND COIL CONNECTION. SUPPORT TERMINAL BOX SUCH THAT IT CAN HANG INDEPENDENTLY OF ANY DUCTWORK CONNECTIONS. ATTACH FOUR STRAP HANGERS TO UNIT. SEAL SCREW PENETRATIONS OF TERMINAL BOX. PROVIDE MINIMUM 8"X8" ACCESS DOOR DOWNSTREAM OF REHEAT COIL. 1 2 3 4 5 6 7 8 9 10 11 . CALIBRATED BALANCING VALVE BALL VALVE (TYPICAL) 2-WAY MODULATING VALVE MANUAL AIR VENT PRESSURE & TEMPERATURE PLUG (TYPICAL) UNION (TYPICAL) STRAINER W/BLOWDOWN AND CAP 3/4" DRAIN W/HOSE CONNECTION AND CAP COIL RETURN SUPPLY 2 3 1 PLAN NOTES PROVIDE BUTTERFLY VALVES IN LIEU OF BALL VALVES WHEN PIPE SIZES ARE ABOVE 2", (TYPICAL). INSTALL AT LOWEST POINT IN PIPING. INSTALL MODULATING VALVE SO THAT STEM IS VERTICAL. 1 2 3 T GATE VALVE STRAINER UNION GATE VALVE 1 PLAN NOTES INSTALL 1/2" BLOW OFF VALVE ON STRAINER WITH NIPPLE AND CAP.1 CHECK VALVE 3/4" VALVE WITH CAPPED NIPPLE 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM D:\Users\MWarren\Documents\04610101-MEP_BSALS_CENTRAL_v2016_mawarren.rvt2/23/2017 10:47:11 AMFEB. 23, 2017 KPM MCW KPM HPE2 TEMPERATURE CONTROL SCHEMATICS, DETAILS, SCHEDULES 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT NO SCALE2TERMINAL BOX CONTROL SCHEMATIC NOSCALE1EXHAUST FAN CONTROL SCHEMATIC SCHEDULE OF DDC POINTS ID DESCRIPTION TREND ALARM GRAPHIC AO-1 EXHAUST DAMPER ED-2 X X BI-1 EXHAUST FAN EF-61 STATUS X X X BI-2 EXHAUST FAN EF-18 STATUS X X X BI-3 CART WASH STATUS X X BO-1 EXHAUST FAN EF-61 START-STOP X BO-2 EXHAUST FAN EF-18 START-STOP X NOSCALE3TERMINAL BOX POWER SUPPLY CONTROL SCHEMATIC FAN SCHEDULE TAG LOCATION AREA SERVED CFM T.S.P. (IN. WG.) FAN TYPE ARRANGEMENT WHEEL TYPE FAN RPM MAX. BHP MOTOR SOUND POWER (MAX. DB) PER OCTAVE BAND (NOTE: INLET SOUND FOR RETURN AND EXHAUST FANS; OUTLET SOUND FOR SUPPLY FANS)SPEED CONTROLBELT DRIVEDIRECT DRIVEBELT GUARDDRAINROOF CURBVIBRATION ISOLATIONUNIT MTD. DISC. SW.WEATHER COVERWEIGHT (LBS) DESIGN REFERENCE NOTESHP RPM VOLTS PHASE 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz MANUFACTURER MODEL EF-18 ROOF DECON 2,000 1.2 UTILITY SET UPBLAST BI 1548 0.7 1 1725 208 1 81 80 77 75 69 66 62 56 Yes No Yes No Yes Yes Yes Yes Yes 150 GREENHECK SWD-15-VG 1 EF-61 ROOF WASHERS 1,200 3.5 UTILITY SET UPBLAST BI 2572 1.2 1.5 1725 208 3 85 85 81 84 81 77 76 72 No Yes No Yes Yes No Yes Yes Yes 150 GREENHECK CSW-12-BI-21-10-I-15 DIFFUSER / GRILLE SCHEDULE TAG NECK SIZE FACE SIZE MATERIAL FINISH CFM RANGE MAX NC MAX THROW (FT) MAX TOTAL ADP (IN WG)MANUFACTURER MODEL NOTES ECG 24X24 24X24 STEEL WHITE 0 - 1500 25 - - PRICE 60 1 S1 10 24X24 STEEL WHITE 251 - 380 20 10 0.09 PRICE SPD - S2 12 24X24 STEEL WHITE 381 - 550 22 12 0.13 PRICE SPD - NO SCALE6NO-LOSS STACK DETAIL NO SCALE4TERMINAL BOX DETAIL NO SCALE52-WAY WATER COIL PIPING DETAIL NO SCALE7STEAM TRAP DETAIL TERMINAL BOX SCHEDULE TAG CFM UNIT INLET SIZE (IN.) DUCT RUNOUT SIZE TO UNIT (IN.) UNIT MAX. A.P.D. AT MAX. CFM (IN.) AIR DATA HOT WATER HEATING COIL DESIGN REFERENCE NOTES COOLING MAX. COOLING MIN. E.A.T. (ºF) L.A.T. (ºF)FLUID GPM E.W.T. (ºF) L.W.T. (ºF) MAX. W.P.D. (FT. HD.) PIPE RUNOUT SIZE TO COIL (IN.) MIN. MBH MANUFACTURER MODEL VAV-1-058 600 600 10" 12" 0.5 55 75 WATER 0.9 180 150 10 3/4" 13.0 PRICE SDV VAV-1-059 1,300 1,300 12" 14" 0.5 55 75 WATER 1.9 180 150 10 3/4" 28.1 PRICE SDV NOTES: 1. EXHAUST FAN HAS BEEN OVERSIZED TO PROVIDE ADDITIONAL EXHAUST CAPACITY TO DECON AS NEEDED TO MAINTAIN NEGATIVE ROOM PRESSURE. BALANCE TO CFM'S SHOWN ON PLAN AS A STARTING POINT. MARK DATE DESCRIPTION T 24252627293031333436 B.6 C G.6 HJ K 40"X24"20"X20"16"X16"16"X16"20"X14"1 2 3 4 4 5 7 7 4 5 T T 8 9 9 4 T 6 24252627293031333436 B.6 C G.6 HJ K 10 11 12 VAV-1-058 VAV-1-059 S2- 500 S1- 300 S2- 500 ECG- 500 ECG- 300 70 CFM ECG- 50020"X14"14"X12"40"X24"20"X20"16"X16"16"X16"6"ø 18 EMG-600 24252627293031333436 B.6 C G.6 HJ K T T T T 13 14 15 16 16 17 13 GENERAL NOTES A.ALL WASHER EXHAUST DUCTWORK SHALL BE WELDED STAINLESS STEEL SLOPED BACK TO WASHER. 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\MWarren\Documents\04610101-MEP_BSALS_CENTRAL_v2016_mawarren.rvt2/23/2017 10:46:57 AMFEB. 23, 2017 KPM AAW KPM H100 PARTIAL HVAC PLANS 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT 1/8" = 1'-0"1 BASEMENT HVAC DEMOLITION PLAN 1/8" = 1'-0"2 BASEMENT HVAC PLAN 1/8" = 1'-0"3 BASEMENT HVAC PIPING PLAN PLAN NOTES 1 EXISTING EXHAUST DUCTWORK TO EXHAUST FAN EF-18. 2 EXISTING EXHAUST DUCTWORK TO EXHAUST FAN EF-61. 3 REMOVE EXISTING SUPPLY DUCTWORK, TERMINAL BOX AND REHEAT COIL BACK TO POINT SHOWN FOR CONNECTION IN NEW WORK. 4 REMOVE EXISTING EXHAUST DUCTWORK BACK TO POINT SHOWN FOR CONNECTION IN NEW WORK. 5 REMOVE EXISTING EXHAUST DUCTWORK BACK TO POINT SHOWN AND CAP. 6 REMOVE EXISTING THERMOSTAT FOR REPLACEMENT. 7 REMOVE EXISTING THERMOSTAT FOR RELOCATION. 8 REMOVE EXISTING REHEAT COIL AND PIPING BACK TO POINT SHOWN FOR CONNECTION IN NEW WORK. 9 REMOVE EXISTING MEDIUM PRESSURE STEAM PIPING DROPS TO EQUIPMENT FOR REPLACEMENT IN NEW WORK. 10 6"Ø EXHAUST DROP TO INSTRUMENT WASHER. BALANCE TO 60 CFM EACH. 11 10"Ø EXHAUST DROP TO CART WASHER. BALANCE TO 1000 CFM. 12 MOTORIZED DAMPER IN CART WASH EXHAUST TO PULL FROM CART WASH SERVICE AREA WHEN CART WASH CONNECTION IS CLOSED BY MANUFACTURER'S INTEGRAL CONTROLS. REFER TO TEMPERATURE CONTROL SCHEMATIC FOR MORE INFORMATION. 13 CONNECT NEW MEDIUM PRESSURE STEAM PIPING TO EXISTING. 14 CONNECT NEW HEATING HOT WATER PIPING TO EXISTING. 15 1/2" MPS AND 1/2" MPR CONNECTION TO EQUIPMENT. PROVIDE ISOLATION VALVES AT EACH CONNECTION. 16 RELOCATED THERMOSTAT. 17 1-1/2" MPS AND 1" MPR CONNECTION TO EQUIPMENT. PROVIDE ISOLATION VALVES AT EACH CONNECTION. 18 FOUR (4) 3" PVC CONDUITS FOR DETERGENT LINES FROM BELOW CEILING TO EACH OF FOUR (4) WASHERS. ALL BENDS TO UTILIZE LONG RADIUS 90 DEGREE ELBOWS OR BACK TO BACK 45 DEGREE ELBOWS. COORDINATE FINAL LOCATION WITH EQUIPMENT MANUFACTURER. MARK DATE DESCRIPTION AA PPQQMM 2625 24 23 22 L' K' J'H' C' A' 2120 M' E' B' DD D' G' 4 EF-18 AA PPQQMM 2625 24 23 22 L' K' J'H' C' A' 2120 M' E' B' DD D' G' 2 KKK JJJ GGG HHH 2625 37 35 32 J'H' 34 3336 30 31 29 27 C' A' E' B' DD D' G' 1 JJJ GGG HHH 2625 37 35 32 J'H' 34 3336 30 31 29 27 C' A' E' B' DD D' G' 3 EF-61 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\JSagen\Documents\04610101-MEP_BSALS_CENTRAL_v2016_jsagen.rvt2/23/2017 12:51:34 PMFEB. 23, 2017 KPM AAW KPM H200 PARTIAL HVAC ROOF PLANS 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT 1/8" = 1'-0"2 THIRD FLOOR ROOF HVAC PLAN 1/8" = 1'-0"1 THIRD FLOOR ROOF HVAC DEMOLITION PLAN 1/8" = 1'-0"3 FIRST FLOOR ROOF HVAC DEMOLITION PLAN 1/8" = 1'-0"4 FIRST FLOOR ROOF HVAC PLAN PLAN NOTES 1 REMOVE EXISTING EXHAUST FAN EF-61 FOR REPLACEMENT IN NEW WORK. 2 REMOVE EXISTING EXHAUST FAN EF-18 FOR REPLACEMENT IN NEW WORK. 3 NEW EXHAUST FAN EF-61 IN SAME LOCATION AS REMOVED FAN. REPLACE ROOF CURB AS NEEDED. 4 NEW EXHAUST FAN EF-18 WEST OF REMOVED FAN. REUSE EXISTING FAN ROOF CURB FOR DUCT PENETRATION. MARK DATE DESCRIPTION A VP T T H FS ΔT T CO ABBREV.ABBREV.ABBREV.DESCRIPTION DESCRIPTION DESCRIPTION GENERAL HVAC AND PLUMBING ABBREVIATIONS A/E ARCHITECT AND ENGINEER AD ACCESS DOOR ADJ ADJUSTABLE OR ADJACENT AFF ABOVE FINISHED FLOOR APPROX APPROXIMATE ARCH ARCHITECT ATM ATMOSPHERE BHP BRAKE HORSEPOWER BLDG BUILDING BOT BOTTOM BTU BRITISH THERMAL UNIT BTUH BTU PER HOUR CAP CAPACITY CENTRIF CENTRIFUGAL CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CFOI CONTRACTOR FURNISHED/OWNER INSTALLED CI CAST IRON CO CLEANOUT COL COLUMN COMP COMPRESSOR CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CSP CEILING SERVICE PANEL DEG DEGREE DEPT DEPARTMENT DIA DIAMETER DISC DISCONNECT DISCH DISCHARGE DN DOWN DWG DRAWING EC ELECTRICAL CONTRACTOR ECC ENVIRONMENTAL CONTROL CONTRACTOR EER ENERGY EFFICIENCY RATING ELEC ELECTRIC ELEV ELEVATION EMER EMERGENCY ENCL ENCLOSURE ENTR ENTERING EQUIP EQUIPMENT ET EXPANSION TANK EWT ENTERING WATER TEMPERATURE EX OR EXIST EXISTING EXT EXTERIOR F DEGREES FAHRENHEIT FC FLEXIBLE CONNECTION FH FUME HOOD FIN FINISH FLA FULL LOAD AMPS FLR FLOOR FPC FIRE PROTECTION CONTRACTOR FT FEET G GAS, NATRUAL GA GAUGE GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR GH GRAVITY HOOD GPM GALLONS PER MINUTE GV GAS, NATURAL VENT GW GLASSWARE WASHER H HEIGHT HD HEAD HGT HEIGHT HOA HAND-OFF-AUTOMATIC HORZ HORIZONTAL HOSP HOSPITAL HP HORSEPOWER HR HOUR HZ HERTZ ID INSIDE DIAMETER OR DIMENSION IN INCHES INCL INCLUDE INSUL INSULATED INT INTERIOR INV INVERT I.P.S.INTERNATIONAL PIPE SIZING JT JOINT KAIC SHORT CIRCUIT RATING KEC KITCHEN EQUIPMENT CONTRACTOR KW KILOWATTS L LENGTH LBS OR #POUNDS LF LINEAR FOOT LFT LEAVING FLUID TEMPERATURE LOC LOCATION LVG LEAVING LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH 1000 BTU/HR MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MOCP MAXIMUM OVERCURRENT PROTECTION MTD MOUNTED N NORTH NA NOT APPLICABLE NC NORMALLY CLOSED OR NOISE CRITERIA NIC NOT IN CONTRACT NO NORMALLY OPEN OR NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED/CONTRACTOR INSTALLED OFOI OWNER FURNISHED/OWNER INSTALLED OPER OPERATOR OPNG OPENING ORIG ORIGINAL P PUMP, PNEUMATIC OR PRESSURE PC PLUMBING CONTRACTOR PD PRESSURE DROP POC POINT OF CONNECTION PPH POUNDS PER HOUR PPM PARTS PER MILLION PREFAB PREFABRICATED PRES PRESSURE PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PVC POLYVINYL CHLORIDE REC RECEIVER RECIRC RECIRCULATING REF REFRIGERATOR RLA RUNNING LOAD AMPS RM ROOM RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR OR SOUND ATTENUATOR SCFM STANDARD CUBIC FEET PER MINUTE SCH SCHEDULE SEC SECTION SENS SENSIBLE SF SQUARE FOOT SHT SHEET SPEC SPECIFICATIONS SQ SQUARE SQFT SQUARE FEET SRV SAFETY RELIEF VALVE SS STAINLESS STEEL STD STANDARD STR STARTER OR STRUCTURE STRUC STRUCTURAL SW SWITCH SYS SYSTEM TCC TEMPERATURE CONTROL CONTRACTOR TDH TOTAL DYNAMIC HEAD TEMP TEMPERATURE TLL TEMPERATURE LOW LIMIT TMBH TOTAL MBH TSP TOTAL STATIC PRESSURE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UVL ULTRA VIOLET LIGHT VB VACUUM BREAKER VEL VELOCITY VFC VARIABLE FREQUENCY CONTROLLER VSC VARIABLE SPEED CONTROLLER VTR VENT THROUGH ROOF W WATTS OR WIDTH W/WITH W/O WITHOUT WC WATER COLUMN WFMD WATER FLOW MEASURING DEVICE WG WATER GAUGE WGT WEIGHT WM WATER METER WP WEATHERPROOF WPD WATER PRESSURE DROP WTR WATER PLUMBING DEMOLITION GENERAL NOTES A.IN EXISTING AREAS, EXISTING SYSTEMS SHOWN ARE BASED ON EXISTING DRAWINGS AND FIELD VERIFIED TO THE EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY THAT SERVICES INDICATED FOR REMOVAL DO NOT SERVE SPACES OUTSIDE THE PROJECT AREA. CONTRACTOR SHALL FIELD VERIFY THAT EXISTING SYSTEMS SHOWN ARE REPRESENTATIVE OF THE INSTALLED SYSTEMS AND REPORT MAJOR DISCREPANCIES TO ENGINEER OF RECORD. B.FOR PHASED SCOPE OF WORK, REFERENCE ARCHITECTURAL PHASING PLANS FOR AREAS OF THE BUILDING INCLUDED IN THE SCOPE OF WORK AND THE CONSTRUCTION PHASING. CONTRACTOR SHALL VERIFY THE FIXTURES, EQUIPMENT AND PIPING TO REMAIN ACTIVE WHERE REQUIRED BY THE PROJECT PHASING AS REQUIRED TO AVOID REMOVAL OF SYSTEMS TO REMAIN. C.INACTIVE, ABANDONED SYSTEMS NOT SHOWN ARE TO BE REPORTED TO THE ENGINEER OF RECORD. D.CONTRACTOR IS TO COORDINATE ALL SERVICE INTERRUPTIONS WITH OWNER REPRESENTATIVES, MAINTENANCE STAFF, AND END-USERS. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCE NOTICE TO ALL AFFECTED PARTIES OF IMPENDING OUTAGE. E.SYSTEMS INDICATED BY DASHED LINES OR RENDERED OBSOLETE BY CONSTRUCTION ARE TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE DESCRIBED BY PLAN NOTE(S). THIS INCLUDES THE REMOVAL OF EXISTING HANGERS, INSULATION, AND ASSOCIATED CONTROLS AND ACCESSORIES. ALL PIPING TERMINATIONS NOT SHOWN AS BEING REUSED SHALL BE CAPPED. CONTRACTOR SHALL PATCH INSULATION DAMAGED DURING DEMOLITION AND WHERE PIPING IS SHOWN TO BE CAPPED. F.WHEN EQUIPMENT REQUIRING ELECTRICAL POWER IS REMOVED, CONTRACTOR SHALL ALSO DEMOLISH EXISTING POWER WIRING AND CONDUIT. A LICENSED ELECTRICIAN SHALL BE RESPONSIBLE FOR REMOVING ALL POWER WIRING AND CONDUIT. G.WHERE MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK PENETRATES EXISTING WALLS OR FLOORS TO REMAIN, THE OPENING CREATED MUST BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND FIRE RATING BY THE GENERAL CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. H.IF THE WORK OF OTHER TRADES IS CURRENTLY SUPPORTED BY WORK TO BE DEMOLISHED, CONTRACTOR SHALL FURNISH AND INSTALL NEW SUPPORTS. I.UNUSED HANGERS FOUND WITHIN THE PROJECT SCOPE AREA SHALL BE REMOVED. J.THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL FOR ANY ITEMS REMOVED FROM THE PROJECT SCOPE AREA. ALL ITEMS NOT CLAIMED BY OWNER SHALL BE REMOVED FROM PREMISES. PLUMBING NEW GENERAL NOTES A.NEW WORK SHOWN ON DRAWINGS IS CONCEPTUAL IN NATURE. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL TRADES. CONTRACTOR SHALL PERFORM FINAL COORDINATION OF ALL TRADES AFTER CEILING REMOVAL ALLOWS FURTHER SITE INVESTIGATION ON EXISTING BUILDINGS. B.UNLESS NOTED OTHERWISE ON THE DRAWINGS, REFER TO SCHEDULES FOR PIPE SIZES TO PLUMBING FIXTURES, DRAINS, AND EQUIPMENT. C.WHERE EQUIPMENT REQUIRING ACCESS MUST BE INSTALLED ABOVE GYPSUM CEILING, CONTRACTOR SHALL COORDINATE ADEQUATE ACCESS WITH ALL TRADES AND PROVIDE THE REQUIRED ACCESS PANELS. D.WHERE EQUIPMENT REQUIRING ACCESS IS INSTALLED BY PLUMBING CONTRACTOR OR OTHER TRADES, ACCESS SHALL BE COORDINATED AND SYSTEMS ROUTED TO ALLOW ACCESS TO EQUIPMENT. E.FOR PHASED SCOPE OF WORK, CONTRACTOR SHALL COORDINATE PHASING REQUIREMENTS WITH ARCHITECTURAL PHASING PLANS. F.CONTRACTOR TO COORDINATE WITH CONSTRUCTION SCHEDULE FOR ALL WORK PERFORMED. G.ALL PIPE PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL DRAWINGS AND EXISTING CONDITIONS. PIPE PENETRATIONS THROUGH CONCRETE BEAMS, JOISTS, OR COLUMNS ARE NOT ACCEPTABLE UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. H.WHERE NEW PIPE PENETRATIONS THROUGH EXISTING CONCRETE SLABS ARE TO OCCUR, CONTRACTOR SHALL LOCATE ANY EXISTING SYSTEMS OR REINFORCING BY X-RAY/SCAN PRIOR TO CORE DRILLING TO AVOID DAMAGE TO SYSTEMS OR REINFORCING. I.PROVIDE WATER HAMMER ARRESTORS AT ALL FLUSH VALVES AND WHERE INDICATED ON PLANS AND DETAILS IN ACCORDNACE WITH PDI-WH-201 GUIDELINES. J.NO PIPING SHALL PASS THROUGH OR BE LOCATED IN ELECTRICAL ROOMS, TELECOM ROOMS, ELEVATOR EQUIPMENT ROOMS, OR STAIR SHAFTS. LINE SYMBOLS LIGHT DOT LINES INDICATE FUTURE WORK LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED FOV PW FO LV LA NG FP CA TW SCW GV GAS VENT PURE WATER FUEL OIL VENT FUEL OIL LABORATORY VACUUM LABORATORY AIR COMPRESSED AIR FIRE PROTECTION GAS, NATURAL TEMPERED WATER SOFT COLD WATER SPECIAL VENT STORM SEWER SPECIAL WASTE 140 DEGREE DOMESTIC HOT WATER SUPPLY 140 DEGREE DOMESTIC HOT WATER CIRCULATION DOMESTIC HOT WATER CIRCULATION DOMESTIC HOT WATER DOMESTIC COLD WATER EQA EQUIPMENT AIR EQV EQUIPMENT VACUUM SV ST SW PLUMBING PIPING SYMBOLS MEDICAL GAS PIPING SYMBOLS CO2 N WAGD MV NO2 O MA V V AI IA AIR INTAKE (MEDICAL , EQUIPMENT, OR INSTRUMENT) VACUUM VENT (MEDICAL OR EQUIPMENT) INSTRUMENT AIR CARBON DIOXIDE WASTE ANESTHESIA GAS DISPOSAL NITROGEN MEDICAL VACUUM NITROUS OXIDE OXYGEN MEDICAL AIR DCW DHW DHWR 140 DHW 140 DHWR VENTV SANITARY SOIL, WASTE SEWERS LABORATORY GAS PIPING SYMBOLS LA N O MRV HE CO2 AR LA-HP LA-LP AI LAB AIR (LOW PRESSURE) LAB AIR (HIGH PRESSURE) AIR INTAKE(LAB) LAB AIR OXYGEN NITROGEN GAS CYLINDER RELIEF VENT HELIUM CARBON DIOXIDE ARGON SG LV SPECIAL GAS (TYPE DENOTED BY -1, -2, ETC.) LAB VACUUM VALVE AND FITTING SYMBOLS CALIBRATED BALANCE VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED NIPPLE W/CAP PIPE WITH BLIND FLANGE CONCENTRIC REDUCER ECCENTRIC REDUCER CHECK VALVE UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE TEMPERATURE CONTROL - 2-WAY MODULATING VALVE TEMPERATURE CONTROL - 2-WAY, 2-POSITION ISOLATION VALVE TEMPERATURE CONTROL - 3-WAY MODULATING VALVE TEMPERATURE CONTROL - 3-WAY, 2-POSITION ISOLATION VALVE SAFETY RELIEF VALVE STRAINER FLOW METER FLOOR DRAIN BY PC AUTOMATIC FLOW CONTROL VALVE FLOW MEASURING DEVICE MANUAL AIR RELIEF VENT AUTOMATIC AIR RELIEF VENT LUBRICATED PLUG VALVE PRESSURE REDUCING VALVE(STEAM, GAS, COMPRESSED AIR) ANGLE VALVE REFRIGERANT HOT GAS BY-PASS VALVE SHUT-OFF COCK (HYDRONICS) SOLENOID VALVE REFRIGERANT EXPANSION VALVE WATER PRESSURE REDUCING/REGULATING VALVE STEAM TRAP DIELECTRIC FITTING BETWEEN STEEL AND COPPER STRAINER (STEAM) PRESSURE AND TEMPERATURE PLUG REFRIGERANT SIGHT GLASS THERMOMETER (P=PRESS V=VAC T=TEMP) GAUGE SENSOR (T-TEMP H-HUMIDITY) FLOW SWITCH CLEAN OUT INDICATED EXPANSION LOOP (COLD SPRUNG) ANCHOR GUIDE REFRIGERANT SHUT-OFF VALVE EXPANSION JOINT DIFFERENTIAL SWITCH NC DETAIL VIEWPLAN VIEWS N0 NC N0 T CONNECTION OF NEW WORK TO EXISTING DETAIL WITH TOP LETTER INDICATING DETAIL DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON SECTION WITH TOP NUMBER INDICATING SECTION DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT SECTION IS CUT ON OR DRAWING THAT SECTION IS DRAWN ON A.GENERAL NOTE 1 FLOOR PLAN SYMBOLS PLAN NOTE THERMOSTAT H HUMIDISTAT A101 1 TYP 1 A101 TYP 1.PLAN NOTE LIST ISOLATION VALVE PM PRESSURE MONITOR (FLOOR PLAN) Co2 Co2 MONITOR (FLOOR PLAN) REDUCED PRESSURE BACKFLOW PREVENTER DOUBLE CHECK VALVE ASSEMBLY FIRE DEPARTMENT CONNECTION FIRE PROTECTION CONTROL VALVE FIRE PROTECTION DEMOLITION GENERAL NOTES A.EXISTING SYSTEMS SHOWN ARE BASED ON EXISTING DRAWINGS AND FIELD VERIFIED TO THE EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY THAT SERVICES INDICATED FOR REMOVAL DO NOT SERVE SPACES OUTSIDE THE PROJECT AREA. CONTRACTOR SHALL FIELD VERIFY THAT EXISTING SYSTEMS SHOWN ARE REPRESENTATIVE OF THE INSTALLED SYSTEMS AND REPORT MAJOR DISCREPANCIES TO ENGINEER OF RECORD. B.FOR PHASED SCOPE OF WORK, REFERENCE ARCHITECTURAL PHASING PLANS FOR AREAS OF THE BUILDING INCLUDED IN THE SCOPE OF WORK AND THE CONSTRUCTION PHASING. C.IN AREAS OF RENOVATION, INACTIVE AND ABANDONED SYSTEMS NOT SHOWN ARE TO BE REPORTED TO THE ENGINEER OF RECORD. D.CONTRACTOR IS TO COORDINATE ALL SERVICE INTERRUPTIONS WITH OWNER REPRESENTATIVES, MAINTENANCE STAFF, AND END-USERS. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCE NOTICE TO ALL AFFECTED PARTIES OF IMPENDING OUTAGE. E.SYSTEMS INDICATED BY DASHED LINES OR RENDERED OBSOLETE BY CONSTRUCTION ARE TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE DESCRIBED BY PLAN NOTE(S). THIS INCLUDES THE REMOVAL OF EXISTING HANGERS, INSULATION, AND ASSOCIATED CONTROLS AND ACCESSORIES. ALL PIPING TERMINATIONS NOT SHOWN AS BEING REUSED SHALL BE CAPPED. CONTRACTOR SHALL PATCH INSULATION DAMAGED DURING DEMOLITION AND WHERE PIPING IS SHOWN TO BE CAPPED. F.WHEN EQUIPMENT REQUIRING ELECTRICAL POWER IS REMOVED, CONTRACTOR SHALL ALSO DEMOLISH EXISTING POWER WIRING AND CONDUIT. A LICENSED ELECTRICIAN SHALL BE RESPONSIBLE FOR REMOVING ALL POWER WIRING AND CONDUIT. G.WHERE MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK PENETRATES EXISTING WALLS OR FLOORS TO REMAIN, THE OPENING CREATED MUST BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND FIRE RATING BY THE GENERAL CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. H.IF THE WORK OF OTHER TRADES IS CURRENTLY SUPPORTED BY WORK TO BE DEMOLISHED, CONTRACTOR SHALL FURNISH AND INSTALL NEW SUPPORTS. I.UNUSED HANGERS FOUND WITHIN THE PROJECT SCOPE AREA SHALL BE REMOVED. FIRE PROTECTION GENERAL NOTES A.WHERE RENOVATIONS OCCUR, MODIFY EXISTING SPRINKLER COVERAGE TO ACCOMMODATE NEW LAYOUT. REFER TO ARCHITECTURAL PLANS FOR CHANGES TO THE AREA OF SCOPE. COORDINATE SYSTEMS WITH EXISTING AND NEW SERVICES. B.WHERE EQUIPMENT REQUIRING ACCESS MUST BE INSTALLED ABOVE GYPSUM CEILING, CONTRACTOR SHALL COORDINATE ADEQUATE ACCESS WITH ALL TRADES AND PROVIDE THE REQUIRED ACCESS PANELS. C.WHERE EQUIPMENT REQUIRING ACCESS IS INSTALLED BY FIRE PROTECTION CONTRACTOR OR OTHER TRADES, ACCESS SHALL BE COORDINATED AND SYSTEMS ROUTED TO ALLOW ACCESS TO EQUIPMENT. D.WHERE PROJECT SCOPE IS PHASED, CONTRACTOR SHALL COORDINATE PHASING REQUIREMENTS WITH ARCHITECTURAL PHASING PLANS. E.CONTRACTOR TO COORDINATE WITH CONSTRUCTION SCHEDULE FOR ALL WORK PERFORMED. F.WHERE NEW WORK IS BEING PERFORMED ON AN EXISTING BUILDING, CONTRACTOR SHALL SCHEDULE SHUTDOWN OF EXISTING FIRE SUPPRESSION SYSTEM WITH OWNER AND NOTIFY LOCAL FIRE DEPARTMENT OF SYSTEM AND AREAS OUT OF SERVICE. PROVIDE FIRE WATCH OF AREAS AND SYSTEMS AFFECTED. G.SPRINKLER PIPING SERVING ELECTRICAL ROOMS, TELECOM ROOMS, AND OTHER SIMILAR SPACES SHALL BE MINIMIZED TO ONLY THE SPRINKLER PIPING AND HEAD THAT SERVES THE SPACE. SPRINKLER PIPING SERVING THESE SPACES SHALL BE ROUTED IN SUCH A MANNER TO MINIMIZE PIPING WITHIN THE ROOM AND SHALL NOT BE ROUTED OVER ELECTRICAL PANELS OR EQUIPMENT WITHIN THE ROOM. H.ALL PIPE PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL DRAWINGS AND EXISTING CONDITIONS. PIPE PENETRATIONS THROUGH CONCRETE BEAMS, JOISTS, OR COLUMNS ARE NOT ACCEPTABLE UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. I.FIRE PROTECTION CONTRACTOR TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH NFPA, STATE, AND LOCAL CODES. COORDINATE WIRING OF FIRE ALARM DEVICES WITH ELECTRICAL CONTRACTOR. ABBREV.ABBREV.ABBREV.DESCRIPTION DESCRIPTION DESCRIPTION PLUMBING ABBREVIATIONS NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT AI AIR INTAKE AR AIR RECIEVER AV ACID VENT AW ACID WASTE BP BRINE PUMP BST BULK SALT STORAGE CA COMPRESSED AIR CO2 CARBON DIOXIDE DCV OR DCVA DOUBLE CHECK VALVE ASSEMBLY DCW DOMESTIC COLD WATER DCWBP DOMESTIC COLD WATER BOOSTER PUMP DHWBP DOMETIC HOT WATER BOOSTER PUMP DHW DOMESTIC HOT WATER DHWR DOMESTIC HOT WATER RETURN DI DEIONIZED WATER DS DOWNSPOUT DSWBP DOMESTIC SOFT WATER BOOSTER PUMP DW DISTILLED WATER DWBP DOMESTIC WATER BOOSTER PUMP DWH DOMESTIC WATER HEATER ECO EXTERIOR CLEANOUT EQA EQUIPMENT AIR EQAC EQUIPMENT AIR COMPRESSOR EQAI EQUIPMENT AIR INTAKE EQV EQUIPMENT VACUUM EQVP EQUIPMENT VACUUM PUMP EQVV EQUIPMENT VACUUM VENT ES EMERGENCY SHOWER ESP ELEVATOR SUMP PUMP EW EMERGENCY EYEWASH EWC ELECTRIC WATER COOLER FCO FLOOR CLEANOUT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FH FIRE HOSE FHC FIRE HOSE CABINET FO FUEL OIL FODT FUEL OIL DAY TANK FOP FUEL OIL PUMP FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOST FUEL OIL STORAGE TANK FOV FUEL OIL VENT GI GREASE INTERCEPTOR GPH GALLONS PER HOUR GT GREASE TRAP HO HUB OUTLET HWC HOT WATER RECIRC HWCP HOT WATER CIRCULATING PUMP IA INSTRUMENT AIR IAC INSTRUMENT AIR COMPRESSOR IAD INSTRUMENT AIR DRYER JP JOCKEY PUMP JPC JOCKEY PUMP LA LAB AIR LAC LAB AIR COMPRESSOR LAD LAB AIR DRYER LAV LAVATORY LV LAB VACUUM LVP LAB VACUUM PUMP MA MEDICAL AIR MAC MEDICAL AIR COMPRESSOR MAD MEDICAL AIR DRYER MAI MEDICAL AIR INTAKE MAM MEDICAL AIR MANFOLD MB MOP BASIN MH MANHOLE MV MEDICAL VACUUM MVP MEDICAL VACUUM PUMP N NITROGEN NM NITROGEN MANIFOLD NOM NITROUS OXIDE MANIFOLD O OXYGEN OD OR ORD OVERFLOW DRAIN OM OXYGEN MANIFOLD OSD OPEN SITE DRAIN PIV POST INDICATOR VALVE PPM PARTS PER MILLION PT PLASTER TRAP PW PURE WATER PWP PURE WATER PUMP PWR PURE WATER RETURN PWS PURE WATER SUPPLY PWST PURE WATER STORAGE TANK RB REFRIGERATOR BOX RD ROOF DRAIN ROM REVERSE OSMOSIS MACHINE ROP REVERSE OSMOSIS PUMP ROST REVERSE OSMOSIS STORAGE TANK RPZ REDUCED PRESSURE BACKFLOW PREVENTER S OR SAN SANITARY OR SEWER SCW SOFT COLD WATER SD SCUPPER DRAIN SEP SEWAGE EJECTOR PUMP SK SINK SP STORM PUMP OR SUMP PUMP ST STORM STR STARTER OR STRUCTURE STRUC STRUCTURAL SV SPECIAL VENT SW SPECIAL WASTE TMV THERMOSTATIC MIXING VALVE TW TEPID OR TEMPERED WATER UR URINAL V VENT VAC VACUUM V V VACUUM VENT W WASTE WAGD WASTE ANESTHESIA GAS DISPOSAL WB WALL BOX WC WATER CLOSET WCO WALL CLEANOUT WH WALL HYDRANT WS WATER SOFTENER OR WASTE STACK 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM D:\Users\MWarren\Documents\04610101-MEP_BSALS_CENTRAL_v2016_mawarren.rvt2/23/2017 10:47:49 AMFEB. 23, 2017 KPM SRB SRB P001 PLUMBING SYMBOLS, ABBREVIATIONS AND GENERAL NOTES 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT MARK DATE DESCRIPTION 242527303336 B.6 C G.6 H 1 2 3 4 5 6 9 6 1 66 4" S(CI) 3" S(CI) 11 4" S(CI) 242527303336 B.6 C G.6 H 137 8 10 SK-1 LAV-1 4" S(CI) 4" S(CI)4" S(CI) 4"FS-1 4"FS-1 4"FS-1 4" S(CI) 12 12 12 4" S(CI) 12 13 DOMESTIC WATER SUPPLY PIPING ADJUSTABEL FLOW CONTROL VALVE WATER HAMMER ARRESTOR "E" PRESSURE GAUGE ISOLATION VALVE PURE WATER SUPPLY PIPING ADJUSTABLE FLOW CONTROL VALVE PRESSURE GAUGE ISOLATION VALVE SINGLE CHAMBER WASHER FLOW CONTROL SETTING AND MINIMUM PIPE SIZE DROPS TO EQUIPMENT: COLD WATER: 12 GPM, 1-1/4" HOT WATER: 12 GPM, 1-1/4" PURE WATER: 8 GPM, 1" CART WASHER FLOW CONTROL SETTING: COLD WATER: 35 GPM, 1-1/2" HOT WATER: 30 GPM, 1-1/2" PURE WATER: 15 GPM, 1-1/4" PRESSURE GAUGE ISOLATION VALVE 1/2" COMPRESSED AIR PIPING 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH D:\Users\MWarren\Documents\04610101-MEP_BSALS_CENTRAL_v2016_mawarren.rvt2/23/2017 11:17:13 AMFEB. 23, 2017 KPM SRB SRB P200 PLUMBING PLANS 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT 1/8" = 1'-0"1 PLUMBING DEMOLITION PLAN 1/8" = 1'-0"2 PLUMBING PLAN PLAN NOTES 1 REMOVE EXISTING FLOOR SINK. CAP 3” S AT MAIN. 2 REMOVE EXISTING 2” S TO BELOW SLAB AND CAP. CUT AND REMOVE EXISTING V. DHW & DCW TO NEAREST ACTIVE MAIN. 3 DISCONNECT AND REMOVE SERVICES FEEDING SONIC WASHER TO ALLOW FOR FLOOR REPLACEMENT. RECONNECT ALL SERVICES FOR RE-INSTALLED SONIC WASHER. 4 REMOVE EXISTING FOOT PEDALS AND ASSOCIATED PIPING TO ALLOW FOR FLOOR REPLACEMENT. RECONNECT ALL SERVICES FOR RE-INSTALLED 3-COMPARTMENT SINK. 5 REMOVE EXISTING CA DROP THRU CEILING. PREP EXISTING CA ABOVE CEILING FOR RECONNECTION. 6 DISCONNECT AND REMOVE EXISTING DHW, DCW, PW SERVING WASHER TO ABOVE NEW EQUIPMENT AND RE-CONNECT. PROVIDE ISOLATION VALVES ON EACH SYSTEM FOR EACH WASHER. MODIFY EXISTING SYSTEMS AS REQUIRED TO ACCOMMODATE NEW EQUIPMENT REQUIREMENTS. 7 CONNECT NEW SK TO EXISTING ROUGH-IN SERVING SK IN ADJOINING BREAKROOM. 8 MODIFY EXISTING FP SYSTEM WITH THIS AREA TO ACCOMMODATE NEW LAYOUT. REPLACE SPRINKLER HEADS. 9 REMOVE EXISTING HANDSINK. ROUGH-IN PIPING TO REMAIN FOR RECONNECTION. 10 CONNECT FIXTURE TO EXISTING ROUGH-IN PIPING. 11 REMOVE EXISTING FLOOR SINK. CAP EXISTING S BELOW SLAB. 12 4" S UP TO FS. 13 EXTEND EXISTING CA TO CEILING OUTLET. PROVIDE ISOLATION VALVE IN CEILING FOR EACH TAKE-OFF. PROVIDE HOSE CONNECTION WITH QUICK CONNECT FITTING AT END OF HOSE. INSTALL BRACKET ON WALL AT 6' AFF FOR HOSE. NO SCALE3STERILIZERS AND WASHERS PIPING DIAGRAM MARK DATE DESCRIPTION PC SD SK SP S4 S3 SSSD HD FD DD AR RI BD M FS TS H H C C S S V DH AM FACP FAAP FANP FATC FGCC FT RA B B M S S S V M M M D S E P CB CP L Z W R A N NC IC X W TV AV MTV DR ES IC MI SCP ML CR MD DC PB K BS DA SM PT REX LC M OC J PC PC P IR RF BS CL WL 2X MO C CT RT HEAVY CONTINUOUS LINES INDICATE SPRINKLER ZONESZ NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK LINE SYMBOLS HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED A.GENERAL NOTE 1 PLAN NOTE FLOOR PLAN SYMBOLS ST - 20 AMP, 125VAC, SAFETY TYPE S - 20 AMP, 125VAC, SURGE GUARD PROTECTION TYPE WP - 20 AMP, 125VAC, WEATHERPROOF TYPE TOGGLE SWITCH - 20 AMP, 120/277VAC LETTER DESIGNATION INDICATES SWITCH LEG FLOOR BOX (POWER AND DATA) SPECIAL RECEPTACLE - EMERGENCY CIRCUIT (SEE DRAWINGS AND SPECIFICATIONS) SPECIAL RECEPTACLE - NORMAL CIRCUIT (SEE DRAWINGS AND SPECIFICATIONS) TOGGLE SWITCH - KEY OPERATED TOGGLE SWITCH - 3-WAY TOGGLE SWITCH - 4-WAY INDIVIDUAL LIGHT DIMMER TOGGLE SWITCH - PILOT LIGHT PLUGSTRIP (POWER AND/OR DATA) HM - 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE IG - 20 AMP, 125VAC, ISOLATED GROUND TYPE GFCI - 20 AMP, 125VAC, GROUND FAULT CURRENT INTERRUPTER TYPE NONE - 20 AMP, 125VAC ELECTRICAL DEVICES DUPLEX RECEPTACLE - EMERGENCY CIRCUIT ("X" DENOTES AS FOLLOWS:) QUADRAPLEX RECEPTACLE - NORMAL CIRCUIT ("X" DENOTES AS FOLLOWS:) QUADRAPLEX RECEPTACLE - EMERGENCY CIRCUIT ("X" DENOTES AS FOLLOWS:) SIMPLEX RECEPTACLE - NORMAL CIRCUIT ("X" DENOTES AS FOLLOWS:) SIMPLEX RECEPTACLE - EMERGENCY CIRCUIT ("X" DENOTES AS FOLLOWS:) DUPLEX RECEPTACLE - NORMAL CIRCUIT ("X" DENOTES AS FOLLOWS:) DESCRIPTIONSYMBOL FLOOR BOX (QUADRAPLEX) FLOOR BOX (DUPLEX) QUADRAPLEX - CEILING MOUNTED DUPLEX - CEILING MOUNTED NURSE ASSIST NURSE ASSIST/CODE BLUE SECURITY SYSTEM QUANTITY OF CONDUCTORS OR CABLES IN CONDUIT JUNCTION OR PULL BOX NEUTRAL GROUND RACEWAY SYSTEM DESCRIPTION PHASE CONDUCTORS SYMBOL SYMBOL DESCRIPTION GENERATOR/ALTERNATOR AUTOMATIC TRANSFER SWITCH G PUSHBUTTON OR PUSH PLATE PAD MOUNTED TRANSFORMER ("X" DENOTES KVA SIZE) BRANCH PANELBOARD AND CABINET - RECESSED MOUNT BRANCH PANELBOARD AND CABINET - SURFACE MOUNT DISTRIBUTION PANELBOARD AND CABINET - SURFACE MOUNT COMBINATION MOTOR CONTROLLER DISCONNECT SWITCH - NON-FUSED MOTOR CONTROLLER DISCONNECT SWITCH - FUSED MOTOR ("X" DENOTES HORSEPOWER) GROUND CONNECTION ELECTRIC THERMOSTAT CAPACITOR ("X" DENOTES KVAR) T X PAGING/AUDIO SYSTEM MICROPHONE INPUT RECEPTACLE - WALL MOUNTED LOUDSPEAKER - WALL MOUNTED LOUDSPEAKER - CEILING MOUNTED SYMBOL VOLUME CONTROL DESCRIPTION WALL MOUNTED PAGING HORN SPEAKER (ROUGH-IN) DESCRIPTION MOLDED CASE CIRCUIT BREAKER CURRENT TRANSFORMER ELECTRICAL EQUIPMENT SYMBOL FIRE ALARM SYSTEM SYMBOL DESCRIPTION TELEVISION SYSTEM SYMBOL TV SYSTEM OUTLET DESCRIPTION TELECOMMUNICATION SYSTEM VOICE ONLY OUTLET VOICE AND DATA OUTLET SYMBOL DESCRIPTION SMOKE DETECTOR ("X" DENOTES AS FOLLOWS) HEAT DETECTOR FLAME DETECTOR DUCT DETECTOR ("X" DENOTES AS FOLLOWS) MANUAL PULL STATION FLOW SWITCH TAMPER SWITCH HORN ONLY - WALL MOUNT HORN STROBE - WALL MOUNT CHIME ONLY - WALL MOUNT CHIME STROBE - WALL MOUNT SPEAKER ONLY - WALL MOUNT SPEAKER STROBE - WALL MOUNT VISUAL ONLY - WALL MOUNT DOOR HOLD OPEN ADDRESSABLE MODULE BEAM DETECTOR FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM NOTIFICATION APPLIANCE PANEL FIRE ALARM TERMINAL CABINET S - SUPPLY R - RETURN R - RELAY BASE REMOTE TEST STATION REMOTE INDICATOR STATION DOOR BUZZER SECURITY MAGNETIC DOOR LOCK CCTV MONITOR OUTLET ELECTRIC DOOR RELEASE BUTTON ELECTRIC DOOR STRIKE INTERCOM UNIT FLUSH MOUNTED MASTER INTERCOM AND DIRECTORY UNIT MOTION DETECTOR - WALL MOUNTED SECURITY CARD READER SECURITY CONTROL PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEYPAD BIOSCAN ACCESS PAD CAMERA VOICE ONLY OUTLET (WALL OUTLET) DATA ONLY OUTLET PHOTOCELL - WALL MOUNTED X P.F. DUTY STATION DESCRIPTION MASTER STATION STAFF STATION STAFF LOCATOR STATION CODE BLUE STATION SYMBOL ROOM READY INDICATOR REMOTE ANNUNCIATOR NURSE STATION INPUT JACK BED CONTROL CABLE/INTERCONNECT JACK NURSE CALL SYSTEM PATIENT STATION - SINGLE OUTLET EMERGENCY/BATH STATION ZONE LIGHT WALL MOUNTED DOME LIGHT ADDRESSABLE RELAY LIGHTING DESCRIPTION 12"x48" LIGHT FIXTURE HALF SHADED INDICATES LIFE SAFETY POWER 24"x24" LIGHT FIXTURE 24" WALL LIGHTS 36" WALL LIGHTS 48" WALL LIGHTS 24"x48" LIGHT FIXTURE DOWN LIGHT WALL MOUNTED SCONCE WALL MOUNTED EMERGENCY BATTERY LIGHT CEILING MOUNTED EMERGENCY BATTERY LIGHT EXIT LIGHT DIRECTIONAL ARROWS CEILING MOUNTED EXIT LIGHT (DUAL FACED) CEILING MOUNTED EXIT LIGHT WALL MOUNTED EXIT LIGHT EXTERIOR POLE LIGHTS (SINGLE HEADS) EXTERIOR POLE LIGHTS (DOUBLE HEADS) EXTERIOR POLE LIGHTS (THREE HEADS) EXTERIOR POLE LIGHTS (FOUR HEADS) EXTERIOR LIGHTS (BOLLARDS) 24" STEM MOUNTED WALL LIGHTS 36" STEM MOUNTED WALL LIGHTS 48" STEM MOUNTED WALL LIGHTS FULL SHADED INDICATES EMERGENCY POWER PATIENT CARE SYSTEM SYMBOL DESCRIPTION DATA ONLY (PATIENT MONITOR) DATA ONLY OUTLET (TELEMETRY) M TM GROUND POINT GROUND ROD a X X FIRE ALARM GRAPHICS COMMAND CENTER FIREMEN'S TELEPHONE RESCUE ASSISTANCE STATION (AREA OF REFUGE) BELL ONLY - WALL MOUNT BELL STROBE - WALL MOUNT MICROPHONE INPUT RECEPTACLE - FLOOR MOUNTED MICROPHONE INPUT RECEPTACLE - CEILING MOUNTED CODE PINK STATION NURSE AUXILIARY JACK TELEMETRY ANTENNA LOCATION CEILING MOUNTED DOME LIGHT EXTERIOR POLE LIGHTS (POLE TOP MOUNT) GROUND FLOOD LIGHT EXTERIOR FLOOD LIGHT DUAL BALLAST (NORMAL AND EMERGENCY) CEILING MOUNTED (DATA, VOICE/DATA) FLOOR BOX (VOICE, DATA, VOICE/DATA) TELECOMMUNICATIONS EQUIPMENT RACK AUDIO/VISUAL CONTROLLER DURESS ALARM (HOLD UP BUTTON) ELECTRIC POWER TRANSFER SECURITY MONITOR SECURITY DOOR REQUEST TO EXIT MOTION DETECTOR LIGHTING CONTROLLER MOTION DETECTOR (LIGHT SWITCH) OCCUPANCY SENSOR - WALL MOUNTED FLOOR BOX (BLANK) PULL CORD PULL CORD WITH AUDIOA PATIENT STATION - SINGLE OUTLET WITHECODE/STAFF ASSIST BUTTON TRACKING SENSOR (IR) TRACKING SENSOR (RF) WHITE BOARD MONITOR DOUBLE NURSE AUXILIARY JACK ASCOM BASE STATION CLOCK SYSTEM SYMBOL WALL MOUNTED CLOCK DESCRIPTION DIGITAL TIME CLOCK/ELAPSED TIME SYSTEM OUTLET WIRELESS ACCESS POINT WAP ABBREV. A or AMP AC A/C ACP ACU ADD ADJ AF AFC AFF AFG AHU AIC AL AM AMB APPROX. ARCH ATS AUTO AVG BC BKR BHP BL BLDG BR BTM C ºC CAB CB or C/B C/C CCTV CKT CL CLG COL COMM COMP CONC CONST CONT CONTR CR CT CU DB DC DEPT DF DIST DM DO DRS DWG EC EF ELEC ELEV ELV EMER ENCL EP EQUIP EWC EX EXH EXP EXT ºF FA FAAP FACP FC FCU FFC FFS FHC FIN FIXT FL FLUOR FLEX-CONN FPC FSS FTG FVR FV FVNR G or GND GALV GC GEN GFCI GFI GFP HGT HH HID HO HOA HORZ HP HPS HTR HV DESCRIPTION AMPERE ALTERNATING CURRENT AIR CONDITIONING ACCESS PANEL AIR CONDITIONING UNIT ADDITION ADJUSTABLE AMPERE FRAME ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALUMINUM AMMETER AMBIENT APPROXIMATELY ARCHITECT AUTOMATIC TRANSFER SWITCH AUTOMATIC AVERAGE BARE COPPER BREAKER BRAKE HORSEPOWER BUILDING LINE BUILDING BRANCH BOTTOM CONDUIT DEGREES CELSIUS CABINET CIRCUIT BREAKER CENTER TO CENTER CLOSED CIRCUIT TELEVISION CIRCUIT CENTER LINE CEILING COLUMN COMMUNICATION COMPRESSOR CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CRITICAL CURRENT TRANSFORMER COPPER DIRECT BURIAL DIRECT CURRENT DEPARTMENT DRINKING FOUNTAIN DISTRIBUTION DEMAND METER DRAWOUT DOCTORS DRAWING ELECTRICAL CONTRACTOR EXHAUST FAN ELECTRIC ELEVATOR ELEVATION EMERGENCY ENCLOSURE ELECTRIC PNEUMATIC EQUIPMENT ELECTRIC WATER COOLER EXPLOSIONPROOF EXHAUST EXPANSION EXTERIOR DEGREES FAHRENHEIT FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FLAT CABLE FAN COIL UNIT FOOD FACILITY CONTRACTOR FOOD FACILITY SUPPLIER FIRE HOSE CABINET FINISH FIXTURE FLOOR FLUORESCENT FLEXIBLE CONNECTION FIRE PROTECTION CONTRACTOR FUSED SAFETY SWITCH FOOTING FILMVIEWER FULL VOLTAGE FULL VOLTAGE NON REVERSING GROUND GALVANIZED GENERAL CONTRACTOR GENERATOR GROUND FAULT CKT. INTERRUPTER GROUND FAULT INTERRUPTER GROUND FAULT PROTECTION HEIGHT HANDHOLE HIGH INTENSITY DISCHARGE HAND OPERATED HAND-OFF-AUTOMATIC HORIZONTAL HORSEPOWER HIGH PRESSURE SODIUM HEATER HIGH VOLTAGE ABBREV. HZ IC ID INCAN INCL ISG JB JT KEC KT KVA KVAR KW LAB LB LF LOC LS LT LTG LV MATV MAX MC MCB MCC MDP MECH MH MIN MISC MLO MTD MTG HT MU OD OFCI OFOI OPNG OPP OR P PB PBOX PE PF PH or Ø PV PNL PL PREFAB PRES PT PTS PW PWR RACU RAD RECEPT REF or REFR REINF RGIP RM RPM SA SC SG SHT SIG SN SPEC SQ SS SSSS STD STN STR SUSP SW SWBD SWGR TCC TELE TEMP TMH TV TYP UC U/C UH UV V VAC VB VC VEL VFD VM VOL VP VSD/VFC W/ W/O WTR WP WT XFMR Z DESCRIPTION HERTZ INTERCOMMUNICATION INSIDE DIAMETER INCANDESCENT INCLUDE ISOLATED GROUND SURGE GUARD JUNCTION BOX JOINT KITCHEN EQUIPMENT CONTRACTOR KITCHENETTE KILOVOLT AMPERE KILOVOLT AMPERE REACTIVE KILOWATT LABORATORY POUND LINEAR FEET LOCATION LIFE SAFETY LIGHT LIGHTING LOW VOLTAGE MASTER ANTENNA TELEVISION MAXIMUM MECHANICAL CONTRACTOR MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MECHANICAL MANHOLE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOUNTING HEIGHT MEDICINE UNIT OUTSIDE DIAMETER OWNER FURNISHED-CONTRACTOR INSTALLED OWNER FURNISHED-OWNER INSTALLED OPENING OPPOSITE OPERATING ROOM POLE PUSHBUTTON PULL BOX PNEUMATIC ELECTRIC CONVERTER POWER FACTOR PHASE POST INDICATOR VALVE PANELBOARD PILOT LIGHT PREFABRICATED PRESSURE PNEUMATIC TUBE PNEUMATIC TUBE STATION PART WINDING POWER ROOM AIR CONDITIONING UNIT RADIATION RECEPTACLE REFRIGERATOR REINFORCED REMOTE GROUND INDICATING PANEL ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SHORT CIRCUIT SURGE GUARD PROTECTION SHEET SIGNAL SOLID NEUTRAL SPECIFICATIONS SQUARE SAFETY SWITCH SOLID STATE SOFT START STANDARD STATION STRUCTURAL SUSPENDED SWITCH SWITCHBOARD SWITCHGEAR TEMPERATURE CONTROL CONTRACTOR TELECOMMUNICATION TEMPERATURE TOP OF MANHOLE TELEVISION TYPICAL UNDER CARPET UNDER CABINET or UNDER COUNTER UNIT HEATER UNIT VENTILATOR VOLT VACUUM VACUUM BREAKER VACUUM CLEANING VELOCITY VARIABLE FREQUENCY DRIVE VOLTMETER VOLUME VAPORPROOF VARIABLE SPEED DRIVE/CONTROLLER WITH WITHOUT WATER WEATHERPROOF WEIGHT TRANSFORMER IMPEDANCE ELECTRICAL ABBREVIATIONS SYMBOL SYMBOL DESCRIPTION S LOUDSPEAKER - CEILING MOUNTED WITH VOLUME CONTROLv PROJ WAP FP FLAT PANEL TV WITH RECESSED WALL BOX PP PUSH PLATE TA TOUCHLESS ACTUATOR PB DOOR RELEASE PUSH BUTTON CR COMBINATION CARD READER WITH KEYPAD DPS DOOR POWER SUPPLY K CAMERA - EXTERIOR CAMERA - PAN/TILT/ZOOM EXT PTZ OC OCCUPANCY SENSOR - CEILING MOUNTED IC INTERCOM - CEILING MOUNTED SHORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH WITH THERMAL OVERLOAD PROTECTION T ADO AUTO DOOR OPERATION MD MOTION DETECTOR - CEILING MOUNTED H H C C S S V B B HORN ONLY - CEILING MOUNT HORN STROBE - CEILING MOUNT CHIME ONLY - CEILING MOUNT CHIME STROBE - CEILING MOUNT SPEAKER ONLY - CEILING MOUNT SPEAKER STROBE - CEILING MOUNT VISUAL ONLY - CEILING MOUNT BELL ONLY - CEILING MOUNT BELL STROBE - CEILING MOUNT PC PHOTOCELL - CEILING MOUNTED VS VACANCY SENSOR - CEILING MOUNTED VS VACANCY SENSOR - WALL MOUNTED RS ROOM STATUS GROUND CONDUIT SIZE AND QUANTITY FEEDER SIZING TABLE F20 DESIGNATION 1212 CONDUCTOR SIZE PER CONDUIT ISOLATED NEUTRAL PHASE & 2P, 1G 1P, 1N, 1GOR 3P, 1G 2P, 1N, 1GOR 3P, 1N, 1G 3P, 3N, 1G 3P, 1N, 2G 3/4"3/4"3/4"3/4"3/4" F30 1010 3/4"3/4"3/4"3/4"3/4" F40-F50 F60 F70-F80 F90-F100 108 3/4"3/4"3/4"1"3/4" 106 3/4"3/4"1"1"1" 84 3/4"1"1-1/4"1-1/4"1-1/4" 83 1"1"1-1/4"1-1/2"1-1/4" FXXX GROUND 12 BUILDING 10 10 10 8 8 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM C:\Users\mburns\Documents\04610101-MEP_BSALS_CENTRAL_v2016_MBURNS714.rvt2/23/2017 11:08:39 AMFEB. 23, 2017 BDH MEB BDH E001 ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT MARK DATE DESCRIPTION S S CCJ JJJ JJJJOC OC LC LCJJJJJJJ J J S S CCGENERAL NOTES A.REFER TO SHEET E001 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. WASHER#2(KLN2-8,10,12) CARTWASH(KHN1-2,4,6) CAVIWAVE-(BLC2-14,16,18) WASHER#3(KLN2-2,4,6) WASHER#1(BLC2-27,29,31) CART WASH WASHERWASHERWASHER KHN1 KLN1 KLN2 1 TYP. 2 3 4 5 5 6 6 CLEAN EQUIPMENT STORAGE BC0055 OFFICE BC0230 ELEVATOR E04 CONFERENCE ROOM BW0040 OFFICE BW0030 ES CLOSET BC0140 CIRCDEPT BW0066 CART STORAGE BW0066 WORK AREA BC0063 STERILIZER BC0059.2 CART STORAGE BC0054 4 TYP 16 16 18 L2 L2 L2 L2L1L2 L1L1L1 L1 15 a a a a a a a a aa a a a a DECONTAM BC0059 ES CLOSET BC0140 OFFICE BW0030 CONFERENCE ROOM BW0040 CIRCDEPT BW0066 CART STORAGE BW0066 CART WASH BC0059.1 CLEAN EQUIPMENT STORAGE BC0055 OFFICE BC0230 ELEVATOR E04 CART STORAGE BC0054 STERILIZER BC0059.2 WORK AREA BC0063 17 17 HDP2 FACP T-2 BLN2 LDP2 T-5 BLC2 KHN1 KLN1 KLN2 BLC2- 27,29,31, F50WASHER #1 WASHER #2 KLN2- 8,10,12, F50 WASHER #3 KLN2- 2,4,6, F50 WASHERWASHERWASHER 7 8 9 10 TYP. KHN1- 2,4,6, F30 11 CART WASH 12 CART WASH +46" +46" 13 14 9 9 12 12 8 18 19 1919 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH C:\Users\mburns\Documents\04610101-MEP_BSALS_CENTRAL_v2016_MBURNS714.rvt2/23/2017 11:08:44 AMFEB. 23, 2017 BDH MEB BDH E100 PARTIAL LOWER LEVEL ELECTRICAL PLANS 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT PLAN NOTES 1 DISCONNECT AND REMOVE EXISTING LIGHITNG IN THIS ROOM. MAINTAIN CIRCUIT FOR RECONNECTING NEW LIGHTING. 2 EXISTING WASHERS TO BE REMOVED. DISCONNECT POWER AND REMOVE CONDUIT AND WIRE COMPLETE BACK TO SOURCE. 3 TEMPORARILY RELOCATE TWO OF THE WASHERS DISCONNECTS TO ALLOW FOR PROJECT PHASING. MODIFY CONDUIT AND WIRING AS REQUIRED. COORDINATE LOCATION IN FIELD. 4 EXISTING CART WASH TO BE REMOVED. DISCONNECT POWER AND REMOVE CONDUIT AND WIRE COMPLETE BACK TO SOURCE. 5 TEMPORARILY SUPPORT EXISTING CEILING MOUNTED DEVICE AS REQUIRED FOR CEILING WORK. REINSTALL IN NEW CEILING IN APPROXIMATELY THE SAME LOCATION. 6 RELOCATE EXISTING ELECTRICAL DEVICES DUE TO WALL DEMOLITION. MODIFY EXISTING CONDUIT AND WIRE AS REQUIRED TO CONNECT AS PRIOR TO DEMOLITION. 7 PROVIDE NEW NON-FUSED DISCONNECTS FOR WASHERS. DISCONNECTS SHALL BE 60A/3P/208V, NEMA 4X. 8 DISCONNECT AND REMOVE EXISTING BREAKER PREVIOUSLY SERVING WASHER. FURNISH AND INSTALL A 50A/3P/208V BREAKER MATCHING TO EXISTING IN EXISTING ITE PANELBOARD BLC2. CONNECT COMPLETE TO WASHER THROUGH DISCONNECT WITH FEEDER SIZE SHOWN. 9 DISCONNECT AND REMOVE EXISTING BREAKERS PREVIOUSLY SERVING WASHERS. FURNISH AND INSTALL TWO 50A/3P/208V BREAKERS MATCHING TO EXISTING IN EXISTING ITE PANELBOARD KLN2. CONNECT COMPLETE TO WASHERS THROUGH DISCONNECTS WITH FEEDER SIZES SHOWN. 10 PROVIDE UNISTRUT SUPPORT FOR MOUNTING OF ELECTRICAL EQUIPMENT ALONG CART WASHER WALL. 11 PROVIDE NEW NON-FUSED DISCONNECT FOR CART WASH. DISCONNECTS SHALL BE 30A/3P/480V, NEMA 4X. 12 DISCONNECT AND REMOVE EXISTING BREAKER PREVIOUSLY SERVING CART WASH. FURNISH AND INSTALL A 20A/3P/480V BREAKERS IN EXISTING ITE PANELBOARD KHN1. CONNECT COMPLETE TO CART WASH THROUGH DISCONNECT WITH FEEDER SIZE SHOWN. 13 CONNECT TO SPARE 20A/1P BREAKER IN EXISTING PANEL BLC2. 14 VAV TERMINAL BOXES TEMPERATURE CONTROL TRANSFORMERS PANEL PER MECHANICAL DISCIPLINE. CONNECT TO 20A/1P/120V EMERGENCY POWER BRANCH CIRCUIT AVAILABLE IN THIS AREA. ALSO PROVIDE TOGGLE SWITCH AT THE UNIT.. 15 CONNECT LIGHT FIXTURES TO CIRCUIT MADE AVAILABLE FROM DEMOLITION. CONNECT COMPLETE THROUGH OCCUPANCY SENSOR/SWITCHLEG SHOWN. 16 EXISTING LIGHT FIXTURE WITH WIRING IN THIS AREA SHALL REMAIN AS IS. DISCONNECT AND REMOVE LIGHT SWITCH TO ACCOMODATE DEMOLITION. 17 PROVIDE NEW SWITCH. EXTEND/MODIFY EXISTING LIGHTING CIRCUIT AND CONNECT THROUGH NEAREST SWITCH. 18 EXISTING PANELBOARD SHALL REMAIN AS IS. 19 REINSTALL EXISTING CEILING MOUNTED DEVICE APPROXIMATLY AT SAME LOCATION. 1/8" = 1'-0"1 LOWER LEVEL ELECTRICAL DEMOLITION PLAN 1/8" = 1'-0"2 LOWER LEVEL LIGHTING PLAN 1/8" = 1'-0"3 LOWER LEVEL POWER PLAN 1/8" = 1'-0"4 LOWER LEVEL SYSTEMS PLAN ELEC_LIGHT FIXTURE SCHEDULE NOTE: SEE SPECIFICATION SECTION 260923, 260933, 260936, 265100, 265561, 265600, 265668 FOR ADDITIONAL INFORMATION REGARDING LIGHTING FIXTURES AND INSTALLATION REQUIREMENTS. PROVIDE OPTIONS AND ACCESSORIES BY THE REFERENCED COLUMN TITLED "OPTIONS / ACCESSORIES". MANUFACTURERS LISTED SHALL MEET ALL REQUIREMENTS AND FEATURES INDICATED. FIXTURE TYPE FIXTURE DIMENSIONS DESCRIPTION VOLTAGE LAMP DATA MANUFACTURER CATALOG SERIES ACCESSORIES/ OPTIONS REMARKSWIDTHLENGTHHEIGHTDIAWATTAGE TYPE COLOR TEMP DELIVERED LUMENS L1 24" 48" 4" 0' - 0" RECESSED, GASKETED CLEAN ROOM TROFFER 120 V 48 W LED 3500K 4800 KENALL CSEDI24 24 - 45L35K - DCC - DV - 5F - 2H - SYM L2 24" 48" 4" 0' - 0" RECESSED, GASKETED CLEAN ROOM TROFFER 120 V 73 W LED 3500K 6900 KENALL CSEDI24 24 - 67L35K - DCC - DV -5F - 2H - SYM MARK DATE DESCRIPTION GENERAL NOTES A.REFER TO SHEET E001 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. 3 12 EF-61 EF-18 30A/3P WP1.5HP 30A/2P WP 1.0HP 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DATE COORD DRAWN APPROVED CLIENT NO.PROJECT NO. TM KEYPLAN PLAN NORTH C:\Users\mburns\Documents\04610101-MEP_BSALS_CENTRAL_v2016_MBURNS714.rvt2/23/2017 11:08:47 AMFEB. 23, 2017 BDH KWB BDH E300 PARTIAL ROOF POWER PLAN 100% CONTRACT DOCUMENTS 04610101 0461 CENTRAL PROCESSING DEPT. (CPD) WASHER REPLACEMENT PLAN NOTES 1 EXISTING EXHAUST FAN EF-18 TO BE REMOVED PER MECHANICAL DISCIPLINE. DISCONNECT POWER AND REMOVE BACK TO SOURCE (PANEL BLN2). 2 NEW EXHAUST FAN EF-18 TO BE PROVIDED PER MECHANICAL DISCIPLINE. FURNISH AND INSTALL A 15A/2P BREAKER IN EXISTING PANEL BLN2. CONNECT COMPLETE TO NEW EXHAUST FAN WITH FEEDER SIZE F20. DISCONNECT BY FAN MANUFACTURER. 3 EXISTING EXHAUST FAN TO BE REPLACED WITH NEW PER MECHANICAL DISCIPLINE. PROVIDE A NEW COMBINATION TYPE FVNR STARTER AND LOCATE IN ADJACENT MECHANICAL ROOM. UTILIZE EXISTING 20A/3P/208V BREAKER IN PANEL KLN1 MADE AVAILABLE FROM DEMOLITION. CONNECT COMPLETE TO NEW EXHAUST FAN THROUGH STARTER WITH FEEDER SIZE F20. DISCONNECT BY FAN MANUFACTURER. 1/8" = 1'-0"1 PARTIAL ROOF ELECTRICAL PLAN MARK DATE DESCRIPTION HSKPG.06eA2/2DECONTDECONTAM02030303030303MODULAR WALL(NOT BY STERIS)05010101 FOR EACH WASHER/CART WASHER, A 3" I.D. CONDUIT RECOMMENDED FROM DETERGENT PUMP LOCATION(S) TO WASHER LOCATION(S) - NOT PROVIDED BY STERISEQUIPMENT LISTTAG QTY DESCRIPTION==========================================================01 3 Reliance Vision Single Chamber Washer/ Disinfector - Double Door/Steam Heat/ Vented/Flush Mounted02 1 Reliance Rack Return03 6 Reliance Transfer Cart04 1 Vision 1327 Cart and Utensil Washer/ Disinfector - Reverse Orientation/Double Door/Pit Mounted/Steam Heat/Pure Water Line05 1 Vision 1327 Service Side Enclosure Panels06E 1 Existing Amsco Sonic Energy ConsolePlanning & Design GroupRSTERIS Corporation5960 Heisley RoadMentor, OH 44060 USASTERIS drawings do not supersede the drawings from the architect of record.DrCkDateScaleH-B-REVISION SCHEDULEDESCRIPTION4ADD ELEVATIONJM/11SEP20155WASHERS/CART WASHERS UPDATED; SCS SYSTEM REMOVED;ADDED RELIANCE RACK RETURN AND DRAIN LOCATIONSJPG/30AUG20166ENLARGED DOORS TO CART WASHER SERVICE AREAMDS/08SEP20167CHANGE CART WASHER TO STANDARD WIDTHMDS/27SEP20168CHANGED WASHERS TO VISION; ADDED LOAD/UNLOADCONVEYORSMDS/18NOV20169CHANGED WASHER TO FLUSH MOUNTED AND CART WASHER TOREVERSE ORIENTATION; ADDED WALLAL/06DEC201610MOVED EQUIPMENT WESTWARD; MODIFIED RECESSINGWALL/ELEVATIONMDS/13FEB2017800-548-48731/4" = 1'-0"05SEP2003JMMDS1R103589PAGE1 OF 3PARTIAL FLOOR PLANSTERILE PROCESSING DEPARTMENTPROPOSED EQUIPMENT LAYOUTST VINCENT CARMEL HOSPITALCARMEL, INDIANA FINISHEDFLOOR634"PIT DEPTH2x2x3/16" STAINLESSSTEEL ANGLE AROUNDPERIMETER OF PIT(SEE NOTES 1 AND 2)6" MIN. (634" MAX.)FINISHED FLOORTO TOP OF PAD(4 PLACES)(SEE NOTE 1)RECOMMENDED 8" MIN. (ROUND OR SQUARE)x 6" DEEP FLOOR SINK WITH 4" O.D.DRAIN OUTLET. DRAIN SHALL FURNISH FOR60 U.S. GPM FLOW (SEE NOTES 1 AND 3)A-A2/2SECTION VIEW - 1327 PIT DETAILSCORNER LEVELING PAD(4 PLACES - SEE NOTE 1)HSKPG.244"(3 PLCS.)DECONT46"118"PIT2114"PIT PAD(2 PLCS.)12"PIT PAD(2 PLCS.)16"PIT PAD(4 PLCS.)22"DRAIN412"DRAIN111"13358"WASHER FLOORDRAIN (3 PLCS.)A-A2/278"PITPlanning & Design GroupRSTERIS Corporation5960 Heisley RoadMentor, OH 44060 USASTERIS drawings do not supersede the drawings from the architect of record.DrCkDateScaleH-B-REVISION SCHEDULEDESCRIPTION4ADD ELEVATIONJM/11SEP20155WASHERS/CART WASHERS UPDATED; SCS SYSTEM REMOVED;ADDED RELIANCE RACK RETURN AND DRAIN LOCATIONSJPG/30AUG20166ENLARGED DOORS TO CART WASHER SERVICE AREAMDS/08SEP20167CHANGE CART WASHER TO STANDARD WIDTHMDS/27SEP20168CHANGED WASHERS TO VISION; ADDED LOAD/UNLOADCONVEYORSMDS/18NOV20169CHANGED WASHER TO FLUSH MOUNTED AND CART WASHER TOREVERSE ORIENTATION; ADDED WALLAL/06DEC201610MOVED EQUIPMENT WESTWARD; MODIFIED RECESSINGWALL/ELEVATIONMDS/13FEB2017800-548-48731/4" = 1'-0"05SEP2003JMMDS1R103589PAGE2 OF 3PARTIAL FLOOR PLANSTERILE PROCESSING DEPARTMENTDRAIN/PIT DETAILSST VINCENT CARMEL HOSPITALCARMEL, INDIANA 96"RECOMMENDEDW.O.(94" MIN.)105"W.O.122"W.O.4812"W.O.FIN. FLOORFIN. CEILING98"RECOMMENDEDCEILINGHEIGHTFOR DOORREMOVAL(94" MIN.)A3/3FINISHED WALL OPENINGS (LOAD SIDE)34"2014"363"329"ITEM01ITEM02ITEM04CART WASHER (UNLOAD SIDE TYPICAL)6"Planning & Design GroupRSTERIS Corporation5960 Heisley RoadMentor, OH 44060 USASTERIS drawings do not supersede the drawings from the architect of record.DrCkDateScaleH-B-REVISION SCHEDULEDESCRIPTION4ADD ELEVATIONJM/11SEP20155WASHERS/CART WASHERS UPDATED; SCS SYSTEM REMOVED;ADDED RELIANCE RACK RETURN AND DRAIN LOCATIONSJPG/30AUG20166ENLARGED DOORS TO CART WASHER SERVICE AREAMDS/08SEP20167CHANGE CART WASHER TO STANDARD WIDTHMDS/27SEP20168CHANGED WASHERS TO VISION; ADDED LOAD/UNLOADCONVEYORSMDS/18NOV20169CHANGED WASHER TO FLUSH MOUNTED AND CART WASHER TOREVERSE ORIENTATION; ADDED WALLAL/06DEC201610MOVED EQUIPMENT WESTWARD; MODIFIED RECESSINGWALL/ELEVATIONMDS/13FEB2017800-548-48731/4" = 1'-0"05SEP2003JMMDS1R103589PAGE3 OF 3PARTIAL ELEVATION PLANSTERILE PROCESSING DEPARTMENTFINISHED W.O. ELEVATIONST VINCENT CARMEL HOSPITALCARMEL, INDIANA