HomeMy WebLinkAbout15A077_ZTA Headquarters_Revision #5 Drawings1
1
2
2
3
3
4
4
5
5
A A
B B
C C
D D
E E
F F
G
H
E.5
C.5
S 429
2 300
OUTDOOR
STORAGE
L08
A-3 470
95 5
ENTRY LOBBY
L05
252
1 300
ELECTRICAL
L07
69
1 300
ELEV. EQUIP.
L03
B 1423
143 100
MAIL ROOM
L06
S 137
1 300
STORAGE
L04
CHASE
6294
32 200
GARAGE
L09
1 HR RATING MIN.
1 HR RATING MIN.
5
5
GENERAL LIFE SAFETY NOTES
1. THE MOST RESTRICTIVE FIRE RATING FOR WALLS AND
OTHER COMPONENTS WHICH ARE SUBJECT TO MULTIPLE
VARYING FIRE RATING REQUIREMENTS SHALL BE THE FIRE
RATING FOR THAT ASSEMBLY.
2. FIRE RATED ASSEMBLIES SHALL COMPLY WITH THE FULL
EXISTING OR ADJACENT WALL
CONSTRUCTION
5/8" TYPE 'X' GYP. BD.
5 1/2" BATT INSULATION - R-16 MIN.
STRUCTURAL DECK ABOVE
5/8" GYP. BD. EACH SIDE
METAL STUD FRAMING AT 16" O.C.
COORDINATE LOCATIONS WITH
STRUCTURAL AND OTHER TRADES.
PROVIDE 3" SOUND ATTENUATION BATT
INSULATION WHEN INDICATED GRAPHICALLY ON
PLANS, SECTIONS, DETAILS, OR BY OTHER
NOTATIONS.
TOP OF SLAB
ACOUSTICAL SEALANT EACH SIDE
ACOUSTICAL SEALANT EACH SIDE
SET METAL STUD TRACK IN BED OF
SEALANT.
CMU SIZE FIRE RATINGS
SEE DETAIL
C CMU WALL
C10
C12 12" CMU
C
1-HR RATED
MIN.
C
2-HR RATED
MIN.
C
3-HR RATED
MIN.
EXTEND TO DECKING ABOVE
C
C4
C6
C8
4" CMU
6" CMU
8" CMU
10" CMU
1
2
3
CMU - SEE STRUCTURAL
FOR REINFORCEMENT
STUD SIZE FIRE RATINGS
SEE DETAIL
CONTRACTOR TO FULLY COMPLY WITH UL
INSTALLATION AND CONSTRUCTION
REQUIREMENTS
B "B" DENOTES TO
PROVIDE BATTS
OF TYPE SHOWN
MA METAL FURRING
MA0
MA1
MA2
MA3
7/8" FURRING
UP
UP
1
1
2
2
3
3
4
4
5
5
A A
B B
C C
D D
E E
F F
G
H
E.5
C.5
STAIR
L01
OUTDOOR
STORAGE
L08
ENTRY
LOBBY
L05
ELEV.
LE01
STAIR
L02
ELECTRICAL
L07
ELEV.
EQUIP.
L03
MAIL
ROOM
L06
ME3
ME3
C8
C8
C8
12' - 8 3/4"
18' - 0" 3' - 4" 9' - 5 1/4"
19' - 10 5/8" 19' - 3 3/8" CLR
5' - 8" 9' - 3 5/8" 6' - 4" 38' - 8 1/2"
19' - 3" CLR
35' - 7 3/4"
GARAGE
L09
L06-1 L08-1
L03-1
L01-2
L01-1
L04-1
Lower Level
88' - 0"
FT FT
5
D1 D2
SEE SCHED.
SEE SCHED.
10" 2' - 4 3/8" 2 1/2"
4 1/2" 4 1/2"
7 1/2"
1 1/2"
SEE SCHED.
SEE SCHED.
D3
SEE SCHED.
SEE SCHED.
FULL LIGHT
3 5/8" 3 5/8"
10" 3 5/8"
5
2nd Floor
114' - 0"
8' - 6"
2" EQ 2" EQ 2" EQ 2" EQ 2"
2" 1' - 6" 2" 4' - 10" 2" 1' - 6" 2"
16' - 3 1/2"
FT
FT
FT
FT
FT
FT
FT
FT
F1 F2 F3
SEE SCHED. 2"
SEE SCHED.
2" 2"
SEE SCHED. 4"
SEE SCHED.
2" 2"
4' - 8 7/8"
2" 3' - 0" 2"
1' - 2 7/8"
2"
7' - 0" 2"
TYP
1' - 2 7/8"
1st Floor
100' - 0"
123-1
7' - 10"
2" 1' - 4 1/2" 8" 2' - 11" 2" 2' - 11"
8' - 0"
2" 7' - 8" 2"
FT
2nd Floor
114' - 0"
216-1
15' - 0"
4' - 6" 6' - 0" 4' - 6"
8' - 8"
2' - 2" 4' - 2" 2' - 4"
FT FT
. .
WF-2
WF-2
4' - 8"
SEE WALL TYPE
4 1/2"
5/8" TYPE 'X' GYP. BD.
MTL. STUDS @ 16" O.C. MAX.
3/8" BACKER ROD AND
SEALANT @ EACH SIDE
OFFSET GLAZED
STOREFRONT SYSTEM
HEAD 01
WOOD SHIM AS NECESSARY
HEAD 02
2"
4 1/4" 4 1/2" 5"
2"
SEE WALL TYPE
5/8" TYPE 'X' GYP. BD.
5 1/2" BATT INSULATION
- R-16 MIN.
8" BOND BEAM W/ (2) #5 BARS TOP AND
BOTTOM IN SOLID GROUT FILL (3000
PSI, 145 PCF)
OFFSET GLAZED
WOOD SHIM AS STOREFRONT SYSTEM
NECESSARY
MTL. STUDS @ 16"
O.C MAX.
WOOD BLOCKING
3/8" BACKER ROD AND
SEALANT @ EACH SIDE
JAMB SIMILAR JAMB SIMILAR
2 X BLOCKING
VAPOR BARRIER
(SHOWN DASHED)
5
HOLLOW METAL
DOOR FRAME -
SOLID GROUT FILL
DOOR AS PER
SCHEDULE
(2) PRECAST CONCRETE UNITS (3000 PSI, 145
PCF), (1) #5 TOP AND BOTTOM 8" DEEP X 4"
WIDE. SCORED TO MATCH WALL PATTERN.
3/8" BACKER ROD AND
SEALANT @ EACH SIDE
5/8" TYPE 'X' GYP. BD.
5 1/2" BATT INSULATION -
R-16 MIN.
MTL. STUDS @ 16"
O.C. MAX.
WOOD BLOCKING
SEE WALL TYPE
VAPOR BARRIER (SHOWN DASHED)
4"
1 1/8" 5 3/4" 7 3/8"
3/8" BACKER ROD AND
SEALANT @ EACH SIDE
5/8" TYPE 'X' GYP. BD.
WOOD BLOCKING
VAPOR BARRIER (SHOWN DASHED)
DOOR AS PER
SCHEDULE
HOLLOW METAL DOOR FRAME
- SOLID GROUT FILL
JAMB ANCHORS (3 PER JAMB)
MTL. STUDS @
16" O.C. MAX.
SEE WALL TYPE
8" CMU - GROUT
SOLID W/ #5 BAR
VERTICAL @ JAMB
DOOR AS PER SCHEDULE
MTL. STUDS @ 16" O.C. MAX.
5/8" TYPE 'X' GYP. BD.
INTERIOR GRADE WOOD FRAME
WOOD SHIM AS NECESSARY
WOOD CASING TO MATCH EXISTING
SEE WALL TYPE
1/4" 1 3/4"
3/4"
SEE WALL TYPE
1 3/4" 1/4"
3/4"
DOOR AS PER SCHEDULE
MTL. STUDS @ 16" O.C. MAX.
5/8" TYPE 'X' GYP. BD.
INTERIOR GRADE WOOD FRAME
WOOD SHIM AS NECESSARY
WOOD CASING TO MATCH EXISTING
2 X BLOCKING
2 X BLOCKING
HEAD 03 HEAD 04
JAMB 01 JAMB 02
1st Floor
100' - 0"
2nd Floor
114' - 0"
13' - 9" STOREFRONT
3" SLAB
8' - 8" STOREFRONT
2"
2' - 6" 2" 7' - 0" 2" 3' - 7" 2"
3"
2"
2' - 6 1/4"
2"
5' - 7 3/4"
2"
1' - 10 5/8"
2" 1' - 6 5/8" 2"
FT
FT
See Drawing
A
R
C
H
I
T
E
C
T
J
O
N
A
T
H
A
N
R
.
H
E
S
S
No.
AR00890137
I
N
D
I
A
N
A
R
E
G
I
S
T
E
R
E
D
STATE OF
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.bdmd.com
Browning Day Mullins Dierdorf Architects
Architecture
Landscape Architecture
Planning
Checked By:
Scale:
Issue Date:
Drawn By:
Project No.:
Owner
3450 Founders Rd.
Indianapolis, IN 46268
Phone: (317) 872-0540
www.zetataualpha.org
Zeta Tau Alpha Fraternity
Structural Engineer
McComas Engineering
MEP Engineer
Circle Design Group
1717 East 116th St., Suite 200
Carmel, Indiana 46032
Phone: (317) 580-0402
www.mccomaseng.com
5510 S. East Street, Suite F
Indianapolis, IN 46227
Phone: (317) 781-6200
www.circledesigngroup.com
Interior Design
8/14/2017 1:56:40 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt
A8.01
Door and Window Details
15A077
Author
Checker
August 7, 2017
Zeta Tau Alpha Headquarters
1036 S. Rangeline Road,
Carmel, IN
100% Construction Documents
DOOR SCHEDULE
Mark Room Name
Hardware
Set
SIZE DOOR FRAME DETAILS
Fire
Width Height Thickness Material Finish Elevation Rating Comments
Frame
Material
Frame
Finish
Frame
Elevation Head Jamb Sill
L01-1 STAIR 3' - 0" 7' - 2" 1 3/4" AL/GL AL EXISTING
L01-2 STAIR 3' - 0" 7' - 0" 1 3/4" HM HM EXISTING
L01-3 STAIR 3' - 0" 7' - 2" 1 3/4" AL/GL AL EXISTING
L02-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
L03-1 ELEV. EQUIP. 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
L04-1 STORAGE 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
L05-1 ENTRY LOBBY #02 3' - 0" 7' - 0" 1 3/4" IHM D3 HM F2 60 MIN 60 MIN FIRE RATED FIREGLASS - SEE SPECS
L06-1 MAIL ROOM #05 6' - 0" 7' - 0" 1 3/4" IHM D2 HM F2 60 MIN PAIR
L06-2 MAIL ROOM #06 6' - 0" 7' - 0" 1 3/4" HM D2 WD F1
L08-1 OUTDOOR STORAGE 6' - 0" 7' - 2" 1 3/4" HM HM EXISTING
L09-1 GARAGE 20' - 0" 9' - 0" 1 3/4" AL STL EXISTING, COILING DOOR
101-1 STAIR 3' - 0" 7' - 0" 1 3/4" HM HM EXISTING
102-1 STAIR 3' - 0" 7' - 0" 1 3/4" HM HM EXISTING
103-1 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE
103-2 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE
103-3 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE
103-4 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE
104-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
105-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
106-1 ARCHIVE #07 6' - 0" 8' - 2" 1 3/4" WD D2 WD F1
106-2 ARCHIVE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
106-3 ARCHIVE #12 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1
107-1 ELECTRICAL 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
108-1 HOUSING CORP SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
109-1 HOUSING CORP SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
110-1 HOUSING CORP SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
110A-1 CLOSET 2' - 6" 7' - 0" 1 3/4" WD WD EXISTING
112-1 MEETING 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
113-1 MAIL ROOM OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
114-1 ARCHIVE STAFF 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
115-1 WORKROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
116-1 SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
117-1 BOARD ROOM #10 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1
118-1 CATERING KITCHEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
119-1 EXEC DINING #09 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1
119-2 EXEC DINING #11 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1 POCKET
119-3 EXEC DINING #11 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1 POCKET
120-1 JAN. 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
121-1 VISITOR OFF 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
122-1 CROWN + CO COORDINATOR OFFICE #08 3' - 0" 7' - 0" 1 3/4" WD D2 WD F3 -REUSE-
123-1 GRAND FOYER #03 6' - 0" 7' - 0" 1 3/4" AL/GL D1 AL STORE PAIR
124-1 EXEC RR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
125-1 EXEC RR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
201-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
202-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
203-1 MOTHERS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
204-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
205-1 MEETING #13 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1
205A-1 CLOSET 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
206-1 MULTI-PURPOSE #14 5' - 0" 7' - 0" 1 3/4" WD D2 WD F1 UNEVEN PAIR
206-2 MULTI-PURPOSE #15 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1
208-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
209-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
210-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
211-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
212-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
213-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
214-1 JAN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
215-1 CONFERENCE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
215-2 CONFERENCE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
215A-1 CLOSET 6' - 0" 7' - 0" 1 3/4" WD WD EXISTING
215B-1 ELEC. CLOSET 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
216-1 CORRIDOR #04 6' - 0" 8' - 5 3/4" 1 3/4" GL AL DORMA AGILE 150 SYSTEM - SEE SPECS
217-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
218-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
219-1 LEGAL FILES 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
220-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
222-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
223-1 IT SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
224-1 IT SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
225-1 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
226-1 SERVER ROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
227-1 IT SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
228-1 CATERING KITCHEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
228-2 CATERING KITCHEN #16 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1
229-1 WOMEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
230-1 MEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
301-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
302-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING
303-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
304-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
305-1 JAN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
306-1 ELEC. 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
307-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
308-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
309-1 FOUNDATION OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
310-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
311-1 FOUNDATION OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
312-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
313-1 FOUNDATION OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
314-1 EXECUTIVE ASSISTANT 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
315-1 EXECUTIVE DIRECTOR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
315-2 EXECUTIVE DIRECTOR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
315A-1 EXECUTIVE DIRECTOR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
317-1 COMM. OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
318-1 VIDEO CONFERENCE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
318A-1 CLOSET 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
319-1 COMM. OFFICE #08 3' - 0" 7' - 0" 1 3/4" WD D2 WD F3 -REUSE-
320-1 OPEN OFFICE 3' - 0" 7' - 0" 1 3/4" AL/GL AL EXISTING
321-1 OPEN OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
321-2 FITNESS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
322-1 OPEN OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
322-2 FITNESS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
323-1 COLLABORATIVE MEETING 3' - 0" 7' - 0" 1 3/4" AL/GL AL EXISTING
324-1 FITNESS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING
324A-1 STEAM 2' - 6" 7' - 0" 1 3/4" - - EXISTING
324B-1 CLOSET 2' - 6" 7' - 0" 1 3/4" WD WD EXISTING
324C-1 SAUNA 2' - 6" 7' - 0" 1 3/4" - - EXISTING
W1
Lobby L05 Glazing
Interior Elevation
A8.01 1/4" = 1'-0"
9 Door Elevations
W3
Meeting 205 Glazing
Interior Elevation
A8.01 1/4" = 1'-0"
8 Frame Elevations
LEGEND:
AL - ALUMINUM
FL - FULLY TEMPERED
GL - GLAZING
HM - HOLLOW METAL
IHM - INSULATED HOLLOW METAL
STL - STEEL
STORE - STOREFRONT/CURTAIN WALL
WD - WOOD
W2
Crown & Co. 123 Glazing
W4
Collab Meeting 216 Glazing
DORMA AGILE 150 GLAZING SYSTEM OFFSET GLAZED KAWNEER
451T STOREFRONT SYSTEM
OFFSET GLAZED KAWNEER
451T STOREFRONT SYSTEM
OFFSET GLAZED KAWNEER
451T STOREFRONT SYSTEM
Detail
A8.01 1 1/2" = 1'-0"
7 Storefront Details
NOTES:
1. CONTRACTOR IS TO REUSE DOORS AND FRAMES
FROM DEMOLITION ANYWHERE APPLICABLE.
2. ALL EXISTING DOORS ARE TO BE STRIPPED AND
STAINED. ALL EXISTING FRAMES TO BE STAINED.
COLOR BY ARCHITECT. TAKE CARE NOT TO DAMAGE
HARDWARE - TO BE REINSTALLED.
Detail
A8.01 1 1/2" = 1'-0"
6 Door Details
W5
Crown & Co Glazing
OFFSET GLAZED KAWNEER
451T STOREFRONT SYSTEM
DOOR SCHEDULE:
DOOR L05-1 AND L06-1 REVISED.
5
REVISION SCHEDULE
Rev. # Revision Description Issue Date
4 For Construction 8/7/2017
5 Revision #5 8/14/2017
L02-1
L09-1
ALIGN
STORAGE
L04
L01-3
ALIGN
CHASE
2' - 0"
6' - 0"
12' - 11 7/8"
MA1
MA1 MA1
MA1
C8
MA1
MA1
MA1
CE3
7
ITEM
L06-2
5
ITEM
1
1
1
1
5
5
5
5
L05-1
5
MA1
GENERAL PLAN NOTES
1. DO NOT SCALE DRAWINGS.
2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF
CONCRETE, FACE OF MASONRY, FACE OF EXISTING
FINISHES, AND COLUMN LINES UNLESS SPECIFICALLY
NOTED OTHERWISE. FINISHED (FIN, FD) OR CLEAR (CLR)
DIMENSIONS INDICATE FINISH SURFACE TO FINISH
SURFACE SPANS BETWEEN WALLS OR FROM FINISH
SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR
OR CENTERLINE OF PLUMBING FIXTURES.
3. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE
BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH
CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO
COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION
SHALL BE PROVIDED BY THE CONTRACTOR REGARDING
SUCH ITEMS.
4. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LOW
VOLTAGE AND FOOD SERVICE ELEMENTS ARE SHOWN
FOR REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE
ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE
CONFLICTS WITH THE ARCHITECT.
5. FLOORS SHALL SLOPE TO FLOOR DRAINS. SLOPES SHALL
COMPLY WITH ADA ACCESSIBILITY GUIDELINES.
6. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES
SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE
UNDERSIDE OF THE DECK ABOVE UNLESS NOTED
OTHERWISE.
7. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED
WITHIN THE DRAWING SET.
8. GENERAL CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING
FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR
PROVIDED ITEMS REPRESENTED WITHIN THE DRAWINGS
AND SPECIFICATIONS.
9. GENERAL CONTRACTOR TO PROVIDE BACKER ROD AND
SEALANT OF A TYPE APPROPRIATE TO EACH CONDITION,
BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR
THROUGHOUT THE INTERIOR AND EXTERIOR OF THE
BUILDING. (COLORS TO BE SELECTED BY ARCHITECT)
10. EACH EXTERIOR STUD WALL ACROSS THE ENTIRETY OF THE
BUILDING IS TO RECEIVE A MINIMUM R-19 BATT INSULATION.
11. SEE STRUCTURAL DRAWINGS FOR INFORMATION
REGARDING CMU AND CAST-IN-PLACE WALLS.
12. ALL EXISTING DOORS, FRAMES AND HARDWARE TO
REMAIN UNLESS OTHERWISE NOTED.
13. ALL EXISTING WINDOW COVERINGS TO REMAIN UNLESS
NOTED OTHERWISE.
EXISTING WALLS TO REMAIN
PLAN LEGEND
NEW CONSTRUCTION
1A WALL TAG: SEE SHEET A0.10 FOR WALL TYPE
AND FIRE RATING REQUIREMENTS. .
CODED NOTES. SEE SCHEDULES
ON THIS PAGE.
DOOR TAG: SEE SHEET A8-SERIES DRAWINGS
SYMBOL LEGEND
1
ITEM
100
W2
GLAZING TAG: SEE SHEET A-8 SERIES
DRAWINGS.
CODED PLAN NOTES
1
ITEM
CUSTOM DISPLAY. SEE A5 SERIES FOR
ELEVATIONS, SECTIONS AND DETAILS.
WALL NEEDS TO SUPPORT TV AND TECHNOLOGY.
PROVIDE BLOCKING IN WALL AS REQUIRED.
2
ITEM
NEW CASEWORK. SEE A5 SERIES FOR ELEVATIONS,
SECTIONS AND DETAILS.
3
ITEM
6" METAL SCUPPER. SEE A3 SERIES FOR DETAILS.
4
ITEM
CHAIN LINK FENCING UP TO FINISH CEILING
W/ 6'-0"W X 7'-0"T DOUBLE SWING GATE.
5
ITEM
6 WOOD FRAMED CASED OPENING. SEE SECTION 8/A5.22.
ITEM
EXISTING ELEVATOR TO REMAIN. NEW DOOR
AND FRAME. SEE INTERIOR ELEVATIONS FOR
FINISHES.
7
ITEM
INTERNALLY LIT, FULL HEIGHT, GLAZED,
DISPLAY CASEWORK. SEE A5 SERIES
DETAILS FOR SIMILAR MATERIALS.
8
ITEM
CROWN AND COMPANY RETAIL DISPLAY. LOW
DRAWERS WITH ADJUSTABLE SHELVING AND
HANGING ABOVE, FULL HANGING.
9
ITEM
WOOD PARTITION WALLS, STAINED TO MATCH WD-
1. REFER TO FINISH PLAN FOR DETAILS.
10
ITEM
EXISTING OPERABLE PARTITION TO REMAIN. SEE
FINISH PLANS FOR FINISH DETAILS.
11
ITEM
See Drawing
A
R
C
H
I
T
E
C
T
J
O
N
A
T
H
A
N
R
.
H
E
S
S
No.
AR00890137
I
N
D
I
A
N
A
R
E
G
I
S
T
E
R
E
D
STATE OF
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.bdmd.com
Browning Day Mullins Dierdorf Architects
Architecture
Landscape Architecture
Planning
Checked By:
Scale:
Issue Date:
Drawn By:
Project No.:
Owner
3450 Founders Rd.
Indianapolis, IN 46268
Phone: (317) 872-0540
www.zetataualpha.org
Zeta Tau Alpha Fraternity
Structural Engineer
McComas Engineering
MEP Engineer
Circle Design Group
1717 East 116th St., Suite 200
Carmel, Indiana 46032
Phone: (317) 580-0402
www.mccomaseng.com
5510 S. East Street, Suite F
Indianapolis, IN 46227
Phone: (317) 781-6200
www.circledesigngroup.com
Interior Design
8/14/2017 1:56:39 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt
A1.00
Lower Level Plan
15A077
Author
Checker
August 7, 2017
Zeta Tau Alpha Headquarters
1036 S. Rangeline Road,
Carmel, IN
100% Construction Documents
Floor Plan
A1.00 1/8" = 1'-0"
1 Lower Level Plan
NORTH
0' 4' 8' 16' 32'
REVISION SCHEDULE
Rev. # Revision Description Issue Date
4 For Construction 8/7/2017
5 Revision #5 8/14/2017
1 1/2" FURRING
2 1/2" STUD
3 5/8" STUD
MA4
MA6
MA8
4" STUD
6" STUD
8" STUD
MA
MA
SECTION
MA
MA
STUD SIZE FIRE RATINGS
SEE DETAIL
CONTRACTOR TO FULLY COMPLY WITH UL
INSTALLATION AND CONSTRUCTION
REQUIREMENTS
B "B" DENOTES TO
PROVIDE BATTS
OF TYPE SHOWN
ME METAL STUD WALL TYPE
ME0
ME1
ME2
ME3
7/8" FURRING
1 1/2" FURRING
2 1/2" STUD
3 5/8" STUD
ME4
ME6
ME8
4" STUD
6" STUD
8" STUD
ME
1-HR FIRE
PARTITION
UL: U-419
ME
STC: 45 to 49 WITH 3" SAB
GYPSUM ASSOCIATION WP-1070
SECTION
ME
ME
1
STUD SIZE FIRE RATINGS
SEE DETAIL
CONTRACTOR TO FULLY COMPLY WITH UL
INSTALLATION AND CONSTRUCTION
REQUIREMENTS
B "B" DENOTES TO
PROVIDE BATTS
OF TYPE SHOWN
CE3 COLUMN ENCLOSURE
CE30
CE31
CE32
CE33
CE34
CE36
CE38
CE3 1-HR RATED
CE3
PLAN
CE3
CE3
2 1/2" MTL. STUDS
@ 16" O.C. MAX.
5/8" TYPE 'X' GYP.
BD.
STRUCTURAL DECK ABOVE
5/8" GYP. BD. ONE SIDE
METAL STUD FRAMING AT 16" O.C.
COORDINATE LOCATIONS WITH
STRUCTURAL AND OTHER TRADES.
PROVIDE 3" SOUND ATTENUATION BATT
INSULATION WHEN INDICATED GRAPHICALLY ON
PLANS, SECTIONS, DETAILS, OR BY OTHER
NOTATIONS.
TOP OF SLAB
ACOUSTICAL SEALANT EACH SIDE
ACOUSTICAL SEALANT EACH SIDE
SET METAL STUD TRACK IN BED OF
SEALANT.
STUD SIZE FIRE RATINGS
SEE DETAIL
CONTRACTOR TO FULLY COMPLY WITH UL
INSTALLATION AND CONSTRUCTION
REQUIREMENTS
B "B" DENOTES TO
PROVIDE BATTS
OF TYPE SHOWN
MF METAL STUD WALL TYPE
MF0
MF1
MF2
MF3
7/8" FURRING
1 1/2" FURRING
2 1/2" STUD
3 5/8" STUD
MF4
MF6
MF8
4" STUD
6" STUD
8" STUD
MF
MF
STC: 45 to 49 WITH 3" SAB
GYPSUM ASSOCIATION WP-1070
SECTION
MF
MF
1
METAL STUD FRAMING AT 16" O.C.
COORDINATE LOCATIONS WITH
STRUCTURAL AND OTHER TRADES.
VAPOR BARRIER
1 7/8" AIR SPACE
5
PROVIDE BACKER ROD AND
FIREPROOF SEALANT AS
REQUIRED
DECKING ABOVE
PROVIDE MINERAL WOOL
FIRESTOP INSULATION INFILL
AS REQUIRED WHERE CMU
MEETS DECK
VERTICAL CONTROL JOINTS
ARE TO CONTAIN CERAMIC
FIBER BLANKET W/ BACKER
ROD AND SEALANT WHERE
REQUIRED FOR FIRE RATING
GENERAL WALL TYPE NOTES
1. PROVIDE MOISTURE RESISTANT GYP. BD. AT TOILET
ROOMS, KITCHENS, JANITOR'S CLOSETS, COUNTERTOPS
WITH SINKS, AND OTHER SIMILAR LOCATIONS.
2. PROVIDE AN ADDITIONAL 1/4" TILE BACKER BOARD ON WALL
SURFACES TO RECEIVE A TILE FINISH. SEE INTERIOR FINISH
SPECIFICATIONS, SCHEDULES AND DETAILS.
3. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES AND
AROUND ALL WALL PENETRATIONS. SEE SPECIFICATIONS.
4. SEE SPECIFICATION FOR MATERIALS INDICATED ON THE
WALL TYPE LEGEND.
5. SEE INTERIOR FINISH SPECIFICATIONS, SCHEDULES, AND
DETAILS FOR ADDITIONAL WALL FINISH MATERIAL
REQUIREMENTS.
6. PROVIDE ADDITIONAL LAYERS OF GYP. BD., BLOCKING, OR
FRAMING AS NEEDED TO ACCOUNT FOR ALIGNING OF WALL
TYPES OR FLUSH CONDITIONS.
7. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND
FROM TOP OF SLAB TIGHT TO UNDERSIDE OF DECK
UNLESS NOTED OTHERWISE.
8. VERIFY FIRE RATINGS OF WALLS WITH BUILDING SUMMARY
AND OTHER NOTATIONS THROUGHOUT THE DRAWING SET.
9. VERIFY STRUCTURAL LOAD BEARING COMPONANTS OF
WALLS WITH STRUCTURAL DRAWINGS.
10. STUD CONTRACTOR TO PROVIDE IN-WALL BLOCKING FOR
CONTRACTOR PROVIDED ITEMS AND FOR OWNER PROVIDED
ITEMS. COORDINATE WITH OWNER.
11. PROVIDE VERTICAL AND HORIZONTAL DRAFT STOPPING IN
WALLS AND WALL CAVITIES AT 10' O.C. MAXIMUM INTERVALS
FOR THE FULL EXTENT OF WALL.
12. CONTRACTOR TO DETERMINE GAUGING AND RELATED
ENGINEERING FOR STUDS NOT OTHERWISE ESTABLISHED
IN THE STRUCTURAL DRAWINGS. CONTRACTOR TO NOTIFY
ARCHITECT OF ANY DESCREPANCIES.
13. CONTRACTOR TO FULLY COMPLY WITH CONSTRUCTION
REQUIREMENTS OF FIRE RATED ASSEMBLIES AS
ESTABLISHED BY UL.
14. CONTRACTOR TO FULLY COMPLY WITH CONSTRUCTION
REQUIREMENTS TO OBTAIN DESIGNATED STC RATINGS AS
ESTABLISHED BY THE GYPSUM ASSOCIATION.
15. EACH FLOOR TRACK OF WALL ASSEMBLIES DESIGNATED
WITH AN STC RATING ARE TO BE SET IN A CONTINUOUS
BED OF SEALANT.
16. FIRE RESISTANCE RATED WALLS SHALL USE RATED FIRE
RESISTANT FILL MATERIALS IN CONJUNCTION WITH
APPROPRIATELY RATED FIRE STOPPING SYSTEM. NON-
FIRE-RATED WALLS SHALL USE ACOUSTICAL SEALANT.
17. EXTERIOR WALLS AND FIRE RESISTANCE RATED WALLS
SHALL USE MINERAL WOOL INSULATION. NON-RATED WALLS
REQUIRING SOUND ATTENUATION SHALL USE SOUND
ATTENUATION BLANKETS.
18. RETURN GYP. BD. AND INTERIOR FINISHES INTO OPENINGS
IN WALLS.
19. RETURN BRICK AT EACH EXTERIOR WALL OPENING.
20. FIRE PARTITIONS OF THE SAME FIRE RATING MAY HAVE A
COMMON DRAFT-STOPPED CAVITY. FIRE BARRIERS MAY
NOT SHARE A COMMON CAVITY WITH OTHER ASSEMBLIES
AND UNINTERUPTED CONTINUITY OF THE FIRE BARRIER
ASSEMBLY MUST BE MAINTAINED FOR THE FULL EXTENT
OF THAT WALL.
21. SEE STRUCTURAL DRAWINGS FOR LOCATIONS WHERE
ADDITIONAL LAYERS OF SHEATHING ARE REQUIRED.
22. FIRE RATED ASSEMBLIES ARE TO CONTAIN 5/8" TYPE-X
GYP. BD.
See Drawing
A
R
C
H
I
T
E
C
T
J
O
N
A
T
H
A
N
R
.
H
E
S
S
No.
AR00890137
I
N
D
I
A
N
A
R
E
G
I
S
T
E
R
E
D
STATE OF
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.bdmd.com
Browning Day Mullins Dierdorf Architects
Architecture
Landscape Architecture
Planning
Checked By:
Scale:
Issue Date:
Drawn By:
Project No.:
Owner
3450 Founders Rd.
Indianapolis, IN 46268
Phone: (317) 872-0540
www.zetataualpha.org
Zeta Tau Alpha Fraternity
Structural Engineer
McComas Engineering
MEP Engineer
Circle Design Group
1717 East 116th St., Suite 200
Carmel, Indiana 46032
Phone: (317) 580-0402
www.mccomaseng.com
5510 S. East Street, Suite F
Indianapolis, IN 46227
Phone: (317) 781-6200
www.circledesigngroup.com
Interior Design
8/14/2017 1:56:39 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt
A0.10
Wall Types
15A077
Author
Checker
August 7, 2017
Zeta Tau Alpha Headquarters
1036 S. Rangeline Road,
Carmel, IN
100% Construction Documents
REVISION SCHEDULE
Rev. # Revision Description Issue Date
4 For Construction 8/7/2017
5 Revision #5 8/14/2017
CONSTRUCTION AND INSTALLATION REQUIREMENTS
DEFINED BY THEIR DESIGNATED UL-ASSEMBLY.
3. SEE BUILDING CODE SUMMARY ON SHEET 0.01.
4. DIMENSIONS SHOWN ON THE LIFE SAFETY PLANS ARE
FOR MEANS-OF-EGRESS / LIFE-SAFETY REFERENCE ONLY
AND ARE NOT FOR CONSTRUCTION. CONTRACTOR IS TO
UTILIZE PRECISE DIMENSIONS PROVIDED ON A1-SERIES
DRAWINGS FOR FLOOR PLAN CONSTRUCTION
DIMENSIONS.
5. MAXIMUM ALLOWABLE TRAVEL DISTANCE FOR ( R ) and ( M )
OCCUPANCIES IS 250'. PER IAC SECTION 1016.
7. DIMENSIONS LABELED AS "TRAVEL" INDICATE THE EXIT
ACCESS DISTANCE ( TRAVEL DISTANCE ) FROM THE
MIDPOINT BETWEEN TWO EXITS TO EITHER OF THE
ASSOCIATED EXITS.
6. MAXIMUM ALLOWABLE TRAVEL DISTANCE FOR ( B )
OCCUPANCIES IS 300'. PER IAC SECTION 1016.
CODED LIFE SAFETY NOTES
1-Hr
RATED
2-Hr
RATED
3-Hr
RATED
1-HR RATED ASSM. SEE FLOOR PLANS AND WALL TYPES
2-HR RATED ASSM. SEE FLOOR PLANS AND WALL TYPES
3-HR RATED ASSM. SEE FLOOR PLANS AND WALL TYPES
CODED NOTES OF VARYING TYPES:
SEE SCHEDULES ON THIS SHEET
SYMBOL LEGEND
1
FINISH
DENOTES EXIT ACCESS / PATH OF EGRESS
OCCUPANCY GROUP
ROOM
101
E 150
42 20
1
NOMINAL SQ. FT.
NUMBER OF EXITS REQUIRED
OCCUPANT LOAD FACTOR
NUMBER OF OCCUPANTS
See Drawing
A
R
C
H
I
T
E
C
T
J
O
N
A
T
H
A
N
R
.
H
E
S
S
No.
AR00890137
I
N
D
I
A
N
A
R
E
G
I
S
T
E
R
E
D
STATE OF
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.bdmd.com
Browning Day Mullins Dierdorf Architects
Architecture
Landscape Architecture
Planning
Checked By:
Scale:
Issue Date:
Drawn By:
Project No.:
Owner
3450 Founders Rd.
Indianapolis, IN 46268
Phone: (317) 872-0540
www.zetataualpha.org
Zeta Tau Alpha Fraternity
Structural Engineer
McComas Engineering
MEP Engineer
Circle Design Group
1717 East 116th St., Suite 200
Carmel, Indiana 46032
Phone: (317) 580-0402
www.mccomaseng.com
5510 S. East Street, Suite F
Indianapolis, IN 46227
Phone: (317) 781-6200
www.circledesigngroup.com
Interior Design
8/14/2017 1:56:38 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt
A0.00-L
Lower Level Life Safety Plan
15A077
Author
Checker
August 7, 2017
Zeta Tau Alpha Headquarters
1036 S. Rangeline Road,
Carmel, IN
100% Construction Documents
Floor Plan
A0.00-L 1/8" = 1'-0"
1 Lower Level Life Safety Plan
NORTH
0' 4' 8' 16' 32'
REVISION SCHEDULE
Rev. # Revision Description Issue Date
4 For Construction 8/7/2017
5 Revision #5 8/14/2017