Loading...
HomeMy WebLinkAbout15A077_ZTA Headquarters_Revision #5 Drawings1 1 2 2 3 3 4 4 5 5 A A B B C C D D E E F F G H E.5 C.5 S 429 2 300 OUTDOOR STORAGE L08 A-3 470 95 5 ENTRY LOBBY L05 252 1 300 ELECTRICAL L07 69 1 300 ELEV. EQUIP. L03 B 1423 143 100 MAIL ROOM L06 S 137 1 300 STORAGE L04 CHASE 6294 32 200 GARAGE L09 1 HR RATING MIN. 1 HR RATING MIN. 5 5 GENERAL LIFE SAFETY NOTES 1. THE MOST RESTRICTIVE FIRE RATING FOR WALLS AND OTHER COMPONENTS WHICH ARE SUBJECT TO MULTIPLE VARYING FIRE RATING REQUIREMENTS SHALL BE THE FIRE RATING FOR THAT ASSEMBLY. 2. FIRE RATED ASSEMBLIES SHALL COMPLY WITH THE FULL EXISTING OR ADJACENT WALL CONSTRUCTION 5/8" TYPE 'X' GYP. BD. 5 1/2" BATT INSULATION - R-16 MIN. STRUCTURAL DECK ABOVE 5/8" GYP. BD. EACH SIDE METAL STUD FRAMING AT 16" O.C. COORDINATE LOCATIONS WITH STRUCTURAL AND OTHER TRADES. PROVIDE 3" SOUND ATTENUATION BATT INSULATION WHEN INDICATED GRAPHICALLY ON PLANS, SECTIONS, DETAILS, OR BY OTHER NOTATIONS. TOP OF SLAB ACOUSTICAL SEALANT EACH SIDE ACOUSTICAL SEALANT EACH SIDE SET METAL STUD TRACK IN BED OF SEALANT. CMU SIZE FIRE RATINGS SEE DETAIL C CMU WALL C10 C12 12" CMU C 1-HR RATED MIN. C 2-HR RATED MIN. C 3-HR RATED MIN. EXTEND TO DECKING ABOVE C C4 C6 C8 4" CMU 6" CMU 8" CMU 10" CMU 1 2 3 CMU - SEE STRUCTURAL FOR REINFORCEMENT STUD SIZE FIRE RATINGS SEE DETAIL CONTRACTOR TO FULLY COMPLY WITH UL INSTALLATION AND CONSTRUCTION REQUIREMENTS B "B" DENOTES TO PROVIDE BATTS OF TYPE SHOWN MA METAL FURRING MA0 MA1 MA2 MA3 7/8" FURRING UP UP 1 1 2 2 3 3 4 4 5 5 A A B B C C D D E E F F G H E.5 C.5 STAIR L01 OUTDOOR STORAGE L08 ENTRY LOBBY L05 ELEV. LE01 STAIR L02 ELECTRICAL L07 ELEV. EQUIP. L03 MAIL ROOM L06 ME3 ME3 C8 C8 C8 12' - 8 3/4" 18' - 0" 3' - 4" 9' - 5 1/4" 19' - 10 5/8" 19' - 3 3/8" CLR 5' - 8" 9' - 3 5/8" 6' - 4" 38' - 8 1/2" 19' - 3" CLR 35' - 7 3/4" GARAGE L09 L06-1 L08-1 L03-1 L01-2 L01-1 L04-1 Lower Level 88' - 0" FT FT 5 D1 D2 SEE SCHED. SEE SCHED. 10" 2' - 4 3/8" 2 1/2" 4 1/2" 4 1/2" 7 1/2" 1 1/2" SEE SCHED. SEE SCHED. D3 SEE SCHED. SEE SCHED. FULL LIGHT 3 5/8" 3 5/8" 10" 3 5/8" 5 2nd Floor 114' - 0" 8' - 6" 2" EQ 2" EQ 2" EQ 2" EQ 2" 2" 1' - 6" 2" 4' - 10" 2" 1' - 6" 2" 16' - 3 1/2" FT FT FT FT FT FT FT FT F1 F2 F3 SEE SCHED. 2" SEE SCHED. 2" 2" SEE SCHED. 4" SEE SCHED. 2" 2" 4' - 8 7/8" 2" 3' - 0" 2" 1' - 2 7/8" 2" 7' - 0" 2" TYP 1' - 2 7/8" 1st Floor 100' - 0" 123-1 7' - 10" 2" 1' - 4 1/2" 8" 2' - 11" 2" 2' - 11" 8' - 0" 2" 7' - 8" 2" FT 2nd Floor 114' - 0" 216-1 15' - 0" 4' - 6" 6' - 0" 4' - 6" 8' - 8" 2' - 2" 4' - 2" 2' - 4" FT FT . . WF-2 WF-2 4' - 8" SEE WALL TYPE 4 1/2" 5/8" TYPE 'X' GYP. BD. MTL. STUDS @ 16" O.C. MAX. 3/8" BACKER ROD AND SEALANT @ EACH SIDE OFFSET GLAZED STOREFRONT SYSTEM HEAD 01 WOOD SHIM AS NECESSARY HEAD 02 2" 4 1/4" 4 1/2" 5" 2" SEE WALL TYPE 5/8" TYPE 'X' GYP. BD. 5 1/2" BATT INSULATION - R-16 MIN. 8" BOND BEAM W/ (2) #5 BARS TOP AND BOTTOM IN SOLID GROUT FILL (3000 PSI, 145 PCF) OFFSET GLAZED WOOD SHIM AS STOREFRONT SYSTEM NECESSARY MTL. STUDS @ 16" O.C MAX. WOOD BLOCKING 3/8" BACKER ROD AND SEALANT @ EACH SIDE JAMB SIMILAR JAMB SIMILAR 2 X BLOCKING VAPOR BARRIER (SHOWN DASHED) 5 HOLLOW METAL DOOR FRAME - SOLID GROUT FILL DOOR AS PER SCHEDULE (2) PRECAST CONCRETE UNITS (3000 PSI, 145 PCF), (1) #5 TOP AND BOTTOM 8" DEEP X 4" WIDE. SCORED TO MATCH WALL PATTERN. 3/8" BACKER ROD AND SEALANT @ EACH SIDE 5/8" TYPE 'X' GYP. BD. 5 1/2" BATT INSULATION - R-16 MIN. MTL. STUDS @ 16" O.C. MAX. WOOD BLOCKING SEE WALL TYPE VAPOR BARRIER (SHOWN DASHED) 4" 1 1/8" 5 3/4" 7 3/8" 3/8" BACKER ROD AND SEALANT @ EACH SIDE 5/8" TYPE 'X' GYP. BD. WOOD BLOCKING VAPOR BARRIER (SHOWN DASHED) DOOR AS PER SCHEDULE HOLLOW METAL DOOR FRAME - SOLID GROUT FILL JAMB ANCHORS (3 PER JAMB) MTL. STUDS @ 16" O.C. MAX. SEE WALL TYPE 8" CMU - GROUT SOLID W/ #5 BAR VERTICAL @ JAMB DOOR AS PER SCHEDULE MTL. STUDS @ 16" O.C. MAX. 5/8" TYPE 'X' GYP. BD. INTERIOR GRADE WOOD FRAME WOOD SHIM AS NECESSARY WOOD CASING TO MATCH EXISTING SEE WALL TYPE 1/4" 1 3/4" 3/4" SEE WALL TYPE 1 3/4" 1/4" 3/4" DOOR AS PER SCHEDULE MTL. STUDS @ 16" O.C. MAX. 5/8" TYPE 'X' GYP. BD. INTERIOR GRADE WOOD FRAME WOOD SHIM AS NECESSARY WOOD CASING TO MATCH EXISTING 2 X BLOCKING 2 X BLOCKING HEAD 03 HEAD 04 JAMB 01 JAMB 02 1st Floor 100' - 0" 2nd Floor 114' - 0" 13' - 9" STOREFRONT 3" SLAB 8' - 8" STOREFRONT 2" 2' - 6" 2" 7' - 0" 2" 3' - 7" 2" 3" 2" 2' - 6 1/4" 2" 5' - 7 3/4" 2" 1' - 10 5/8" 2" 1' - 6 5/8" 2" FT FT See Drawing A R C H I T E C T J O N A T H A N R . H E S S No. AR00890137 I N D I A N A R E G I S T E R E D STATE OF CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.bdmd.com Browning Day Mullins Dierdorf Architects Architecture Landscape Architecture Planning Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 3450 Founders Rd. Indianapolis, IN 46268 Phone: (317) 872-0540 www.zetataualpha.org Zeta Tau Alpha Fraternity Structural Engineer McComas Engineering MEP Engineer Circle Design Group 1717 East 116th St., Suite 200 Carmel, Indiana 46032 Phone: (317) 580-0402 www.mccomaseng.com 5510 S. East Street, Suite F Indianapolis, IN 46227 Phone: (317) 781-6200 www.circledesigngroup.com Interior Design 8/14/2017 1:56:40 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt A8.01 Door and Window Details 15A077 Author Checker August 7, 2017 Zeta Tau Alpha Headquarters 1036 S. Rangeline Road, Carmel, IN 100% Construction Documents DOOR SCHEDULE Mark Room Name Hardware Set SIZE DOOR FRAME DETAILS Fire Width Height Thickness Material Finish Elevation Rating Comments Frame Material Frame Finish Frame Elevation Head Jamb Sill L01-1 STAIR 3' - 0" 7' - 2" 1 3/4" AL/GL AL EXISTING L01-2 STAIR 3' - 0" 7' - 0" 1 3/4" HM HM EXISTING L01-3 STAIR 3' - 0" 7' - 2" 1 3/4" AL/GL AL EXISTING L02-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING L03-1 ELEV. EQUIP. 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING L04-1 STORAGE 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING L05-1 ENTRY LOBBY #02 3' - 0" 7' - 0" 1 3/4" IHM D3 HM F2 60 MIN 60 MIN FIRE RATED FIREGLASS - SEE SPECS L06-1 MAIL ROOM #05 6' - 0" 7' - 0" 1 3/4" IHM D2 HM F2 60 MIN PAIR L06-2 MAIL ROOM #06 6' - 0" 7' - 0" 1 3/4" HM D2 WD F1 L08-1 OUTDOOR STORAGE 6' - 0" 7' - 2" 1 3/4" HM HM EXISTING L09-1 GARAGE 20' - 0" 9' - 0" 1 3/4" AL STL EXISTING, COILING DOOR 101-1 STAIR 3' - 0" 7' - 0" 1 3/4" HM HM EXISTING 102-1 STAIR 3' - 0" 7' - 0" 1 3/4" HM HM EXISTING 103-1 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE 103-2 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE 103-3 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE 103-4 GRAND FOYER #01 3' - 0" 7' - 10 1/2" 1 3/4" AL/GL D1 AL STORE 104-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 105-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 106-1 ARCHIVE #07 6' - 0" 8' - 2" 1 3/4" WD D2 WD F1 106-2 ARCHIVE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 106-3 ARCHIVE #12 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1 107-1 ELECTRICAL 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 108-1 HOUSING CORP SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 109-1 HOUSING CORP SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 110-1 HOUSING CORP SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 110A-1 CLOSET 2' - 6" 7' - 0" 1 3/4" WD WD EXISTING 112-1 MEETING 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 113-1 MAIL ROOM OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 114-1 ARCHIVE STAFF 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 115-1 WORKROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 116-1 SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 117-1 BOARD ROOM #10 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1 118-1 CATERING KITCHEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 119-1 EXEC DINING #09 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1 119-2 EXEC DINING #11 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1 POCKET 119-3 EXEC DINING #11 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1 POCKET 120-1 JAN. 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 121-1 VISITOR OFF 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 122-1 CROWN + CO COORDINATOR OFFICE #08 3' - 0" 7' - 0" 1 3/4" WD D2 WD F3 -REUSE- 123-1 GRAND FOYER #03 6' - 0" 7' - 0" 1 3/4" AL/GL D1 AL STORE PAIR 124-1 EXEC RR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 125-1 EXEC RR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 201-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING 202-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING 203-1 MOTHERS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 204-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 205-1 MEETING #13 3' - 0" 7' - 0" 1 3/4" WD D2 WD F1 205A-1 CLOSET 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 206-1 MULTI-PURPOSE #14 5' - 0" 7' - 0" 1 3/4" WD D2 WD F1 UNEVEN PAIR 206-2 MULTI-PURPOSE #15 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1 208-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 209-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 210-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 211-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 212-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 213-1 MEMBERSHIP OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 214-1 JAN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 215-1 CONFERENCE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 215-2 CONFERENCE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 215A-1 CLOSET 6' - 0" 7' - 0" 1 3/4" WD WD EXISTING 215B-1 ELEC. CLOSET 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 216-1 CORRIDOR #04 6' - 0" 8' - 5 3/4" 1 3/4" GL AL DORMA AGILE 150 SYSTEM - SEE SPECS 217-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 218-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 219-1 LEGAL FILES 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 220-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 222-1 FINANCE SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 223-1 IT SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 224-1 IT SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 225-1 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 226-1 SERVER ROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 227-1 IT SHARED OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 228-1 CATERING KITCHEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 228-2 CATERING KITCHEN #16 6' - 0" 7' - 0" 1 3/4" WD D2 WD F1 229-1 WOMEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 230-1 MEN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 301-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING 302-1 STAIR 3' - 0" 7' - 0" 1 3/4" WD HM EXISTING 303-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 304-1 RESTROOM 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 305-1 JAN 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 306-1 ELEC. 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 307-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 308-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 309-1 FOUNDATION OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 310-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 311-1 FOUNDATION OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 312-1 OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 313-1 FOUNDATION OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 314-1 EXECUTIVE ASSISTANT 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 315-1 EXECUTIVE DIRECTOR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 315-2 EXECUTIVE DIRECTOR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 315A-1 EXECUTIVE DIRECTOR 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 317-1 COMM. OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 318-1 VIDEO CONFERENCE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 318A-1 CLOSET 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 319-1 COMM. OFFICE #08 3' - 0" 7' - 0" 1 3/4" WD D2 WD F3 -REUSE- 320-1 OPEN OFFICE 3' - 0" 7' - 0" 1 3/4" AL/GL AL EXISTING 321-1 OPEN OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 321-2 FITNESS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 322-1 OPEN OFFICE 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 322-2 FITNESS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 323-1 COLLABORATIVE MEETING 3' - 0" 7' - 0" 1 3/4" AL/GL AL EXISTING 324-1 FITNESS 3' - 0" 7' - 0" 1 3/4" WD WD EXISTING 324A-1 STEAM 2' - 6" 7' - 0" 1 3/4" - - EXISTING 324B-1 CLOSET 2' - 6" 7' - 0" 1 3/4" WD WD EXISTING 324C-1 SAUNA 2' - 6" 7' - 0" 1 3/4" - - EXISTING W1 Lobby L05 Glazing Interior Elevation A8.01 1/4" = 1'-0" 9 Door Elevations W3 Meeting 205 Glazing Interior Elevation A8.01 1/4" = 1'-0" 8 Frame Elevations LEGEND: AL - ALUMINUM FL - FULLY TEMPERED GL - GLAZING HM - HOLLOW METAL IHM - INSULATED HOLLOW METAL STL - STEEL STORE - STOREFRONT/CURTAIN WALL WD - WOOD W2 Crown & Co. 123 Glazing W4 Collab Meeting 216 Glazing DORMA AGILE 150 GLAZING SYSTEM OFFSET GLAZED KAWNEER 451T STOREFRONT SYSTEM OFFSET GLAZED KAWNEER 451T STOREFRONT SYSTEM OFFSET GLAZED KAWNEER 451T STOREFRONT SYSTEM Detail A8.01 1 1/2" = 1'-0" 7 Storefront Details NOTES: 1. CONTRACTOR IS TO REUSE DOORS AND FRAMES FROM DEMOLITION ANYWHERE APPLICABLE. 2. ALL EXISTING DOORS ARE TO BE STRIPPED AND STAINED. ALL EXISTING FRAMES TO BE STAINED. COLOR BY ARCHITECT. TAKE CARE NOT TO DAMAGE HARDWARE - TO BE REINSTALLED. Detail A8.01 1 1/2" = 1'-0" 6 Door Details W5 Crown & Co Glazing OFFSET GLAZED KAWNEER 451T STOREFRONT SYSTEM DOOR SCHEDULE: DOOR L05-1 AND L06-1 REVISED. 5 REVISION SCHEDULE Rev. # Revision Description Issue Date 4 For Construction 8/7/2017 5 Revision #5 8/14/2017 L02-1 L09-1 ALIGN STORAGE L04 L01-3 ALIGN CHASE 2' - 0" 6' - 0" 12' - 11 7/8" MA1 MA1 MA1 MA1 C8 MA1 MA1 MA1 CE3 7 ITEM L06-2 5 ITEM 1 1 1 1 5 5 5 5 L05-1 5 MA1 GENERAL PLAN NOTES 1. DO NOT SCALE DRAWINGS. 2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY, FACE OF EXISTING FINISHES, AND COLUMN LINES UNLESS SPECIFICALLY NOTED OTHERWISE. FINISHED (FIN, FD) OR CLEAR (CLR) DIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALLS OR FROM FINISH SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR OR CENTERLINE OF PLUMBING FIXTURES. 3. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR REGARDING SUCH ITEMS. 4. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE AND FOOD SERVICE ELEMENTS ARE SHOWN FOR REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE CONFLICTS WITH THE ARCHITECT. 5. FLOORS SHALL SLOPE TO FLOOR DRAINS. SLOPES SHALL COMPLY WITH ADA ACCESSIBILITY GUIDELINES. 6. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE UNDERSIDE OF THE DECK ABOVE UNLESS NOTED OTHERWISE. 7. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED WITHIN THE DRAWING SET. 8. GENERAL CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR PROVIDED ITEMS REPRESENTED WITHIN THE DRAWINGS AND SPECIFICATIONS. 9. GENERAL CONTRACTOR TO PROVIDE BACKER ROD AND SEALANT OF A TYPE APPROPRIATE TO EACH CONDITION, BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR THROUGHOUT THE INTERIOR AND EXTERIOR OF THE BUILDING. (COLORS TO BE SELECTED BY ARCHITECT) 10. EACH EXTERIOR STUD WALL ACROSS THE ENTIRETY OF THE BUILDING IS TO RECEIVE A MINIMUM R-19 BATT INSULATION. 11. SEE STRUCTURAL DRAWINGS FOR INFORMATION REGARDING CMU AND CAST-IN-PLACE WALLS. 12. ALL EXISTING DOORS, FRAMES AND HARDWARE TO REMAIN UNLESS OTHERWISE NOTED. 13. ALL EXISTING WINDOW COVERINGS TO REMAIN UNLESS NOTED OTHERWISE. EXISTING WALLS TO REMAIN PLAN LEGEND NEW CONSTRUCTION 1A WALL TAG: SEE SHEET A0.10 FOR WALL TYPE AND FIRE RATING REQUIREMENTS. . CODED NOTES. SEE SCHEDULES ON THIS PAGE. DOOR TAG: SEE SHEET A8-SERIES DRAWINGS SYMBOL LEGEND 1 ITEM 100 W2 GLAZING TAG: SEE SHEET A-8 SERIES DRAWINGS. CODED PLAN NOTES 1 ITEM CUSTOM DISPLAY. SEE A5 SERIES FOR ELEVATIONS, SECTIONS AND DETAILS. WALL NEEDS TO SUPPORT TV AND TECHNOLOGY. PROVIDE BLOCKING IN WALL AS REQUIRED. 2 ITEM NEW CASEWORK. SEE A5 SERIES FOR ELEVATIONS, SECTIONS AND DETAILS. 3 ITEM 6" METAL SCUPPER. SEE A3 SERIES FOR DETAILS. 4 ITEM CHAIN LINK FENCING UP TO FINISH CEILING W/ 6'-0"W X 7'-0"T DOUBLE SWING GATE. 5 ITEM 6 WOOD FRAMED CASED OPENING. SEE SECTION 8/A5.22. ITEM EXISTING ELEVATOR TO REMAIN. NEW DOOR AND FRAME. SEE INTERIOR ELEVATIONS FOR FINISHES. 7 ITEM INTERNALLY LIT, FULL HEIGHT, GLAZED, DISPLAY CASEWORK. SEE A5 SERIES DETAILS FOR SIMILAR MATERIALS. 8 ITEM CROWN AND COMPANY RETAIL DISPLAY. LOW DRAWERS WITH ADJUSTABLE SHELVING AND HANGING ABOVE, FULL HANGING. 9 ITEM WOOD PARTITION WALLS, STAINED TO MATCH WD- 1. REFER TO FINISH PLAN FOR DETAILS. 10 ITEM EXISTING OPERABLE PARTITION TO REMAIN. SEE FINISH PLANS FOR FINISH DETAILS. 11 ITEM See Drawing A R C H I T E C T J O N A T H A N R . H E S S No. AR00890137 I N D I A N A R E G I S T E R E D STATE OF CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.bdmd.com Browning Day Mullins Dierdorf Architects Architecture Landscape Architecture Planning Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 3450 Founders Rd. Indianapolis, IN 46268 Phone: (317) 872-0540 www.zetataualpha.org Zeta Tau Alpha Fraternity Structural Engineer McComas Engineering MEP Engineer Circle Design Group 1717 East 116th St., Suite 200 Carmel, Indiana 46032 Phone: (317) 580-0402 www.mccomaseng.com 5510 S. East Street, Suite F Indianapolis, IN 46227 Phone: (317) 781-6200 www.circledesigngroup.com Interior Design 8/14/2017 1:56:39 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt A1.00 Lower Level Plan 15A077 Author Checker August 7, 2017 Zeta Tau Alpha Headquarters 1036 S. Rangeline Road, Carmel, IN 100% Construction Documents Floor Plan A1.00 1/8" = 1'-0" 1 Lower Level Plan NORTH 0' 4' 8' 16' 32' REVISION SCHEDULE Rev. # Revision Description Issue Date 4 For Construction 8/7/2017 5 Revision #5 8/14/2017 1 1/2" FURRING 2 1/2" STUD 3 5/8" STUD MA4 MA6 MA8 4" STUD 6" STUD 8" STUD MA MA SECTION MA MA STUD SIZE FIRE RATINGS SEE DETAIL CONTRACTOR TO FULLY COMPLY WITH UL INSTALLATION AND CONSTRUCTION REQUIREMENTS B "B" DENOTES TO PROVIDE BATTS OF TYPE SHOWN ME METAL STUD WALL TYPE ME0 ME1 ME2 ME3 7/8" FURRING 1 1/2" FURRING 2 1/2" STUD 3 5/8" STUD ME4 ME6 ME8 4" STUD 6" STUD 8" STUD ME 1-HR FIRE PARTITION UL: U-419 ME STC: 45 to 49 WITH 3" SAB GYPSUM ASSOCIATION WP-1070 SECTION ME ME 1 STUD SIZE FIRE RATINGS SEE DETAIL CONTRACTOR TO FULLY COMPLY WITH UL INSTALLATION AND CONSTRUCTION REQUIREMENTS B "B" DENOTES TO PROVIDE BATTS OF TYPE SHOWN CE3 COLUMN ENCLOSURE CE30 CE31 CE32 CE33 CE34 CE36 CE38 CE3 1-HR RATED CE3 PLAN CE3 CE3 2 1/2" MTL. STUDS @ 16" O.C. MAX. 5/8" TYPE 'X' GYP. BD. STRUCTURAL DECK ABOVE 5/8" GYP. BD. ONE SIDE METAL STUD FRAMING AT 16" O.C. COORDINATE LOCATIONS WITH STRUCTURAL AND OTHER TRADES. PROVIDE 3" SOUND ATTENUATION BATT INSULATION WHEN INDICATED GRAPHICALLY ON PLANS, SECTIONS, DETAILS, OR BY OTHER NOTATIONS. TOP OF SLAB ACOUSTICAL SEALANT EACH SIDE ACOUSTICAL SEALANT EACH SIDE SET METAL STUD TRACK IN BED OF SEALANT. STUD SIZE FIRE RATINGS SEE DETAIL CONTRACTOR TO FULLY COMPLY WITH UL INSTALLATION AND CONSTRUCTION REQUIREMENTS B "B" DENOTES TO PROVIDE BATTS OF TYPE SHOWN MF METAL STUD WALL TYPE MF0 MF1 MF2 MF3 7/8" FURRING 1 1/2" FURRING 2 1/2" STUD 3 5/8" STUD MF4 MF6 MF8 4" STUD 6" STUD 8" STUD MF MF STC: 45 to 49 WITH 3" SAB GYPSUM ASSOCIATION WP-1070 SECTION MF MF 1 METAL STUD FRAMING AT 16" O.C. COORDINATE LOCATIONS WITH STRUCTURAL AND OTHER TRADES. VAPOR BARRIER 1 7/8" AIR SPACE 5 PROVIDE BACKER ROD AND FIREPROOF SEALANT AS REQUIRED DECKING ABOVE PROVIDE MINERAL WOOL FIRESTOP INSULATION INFILL AS REQUIRED WHERE CMU MEETS DECK VERTICAL CONTROL JOINTS ARE TO CONTAIN CERAMIC FIBER BLANKET W/ BACKER ROD AND SEALANT WHERE REQUIRED FOR FIRE RATING GENERAL WALL TYPE NOTES 1. PROVIDE MOISTURE RESISTANT GYP. BD. AT TOILET ROOMS, KITCHENS, JANITOR'S CLOSETS, COUNTERTOPS WITH SINKS, AND OTHER SIMILAR LOCATIONS. 2. PROVIDE AN ADDITIONAL 1/4" TILE BACKER BOARD ON WALL SURFACES TO RECEIVE A TILE FINISH. SEE INTERIOR FINISH SPECIFICATIONS, SCHEDULES AND DETAILS. 3. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES AND AROUND ALL WALL PENETRATIONS. SEE SPECIFICATIONS. 4. SEE SPECIFICATION FOR MATERIALS INDICATED ON THE WALL TYPE LEGEND. 5. SEE INTERIOR FINISH SPECIFICATIONS, SCHEDULES, AND DETAILS FOR ADDITIONAL WALL FINISH MATERIAL REQUIREMENTS. 6. PROVIDE ADDITIONAL LAYERS OF GYP. BD., BLOCKING, OR FRAMING AS NEEDED TO ACCOUNT FOR ALIGNING OF WALL TYPES OR FLUSH CONDITIONS. 7. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE. 8. VERIFY FIRE RATINGS OF WALLS WITH BUILDING SUMMARY AND OTHER NOTATIONS THROUGHOUT THE DRAWING SET. 9. VERIFY STRUCTURAL LOAD BEARING COMPONANTS OF WALLS WITH STRUCTURAL DRAWINGS. 10. STUD CONTRACTOR TO PROVIDE IN-WALL BLOCKING FOR CONTRACTOR PROVIDED ITEMS AND FOR OWNER PROVIDED ITEMS. COORDINATE WITH OWNER. 11. PROVIDE VERTICAL AND HORIZONTAL DRAFT STOPPING IN WALLS AND WALL CAVITIES AT 10' O.C. MAXIMUM INTERVALS FOR THE FULL EXTENT OF WALL. 12. CONTRACTOR TO DETERMINE GAUGING AND RELATED ENGINEERING FOR STUDS NOT OTHERWISE ESTABLISHED IN THE STRUCTURAL DRAWINGS. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DESCREPANCIES. 13. CONTRACTOR TO FULLY COMPLY WITH CONSTRUCTION REQUIREMENTS OF FIRE RATED ASSEMBLIES AS ESTABLISHED BY UL. 14. CONTRACTOR TO FULLY COMPLY WITH CONSTRUCTION REQUIREMENTS TO OBTAIN DESIGNATED STC RATINGS AS ESTABLISHED BY THE GYPSUM ASSOCIATION. 15. EACH FLOOR TRACK OF WALL ASSEMBLIES DESIGNATED WITH AN STC RATING ARE TO BE SET IN A CONTINUOUS BED OF SEALANT. 16. FIRE RESISTANCE RATED WALLS SHALL USE RATED FIRE RESISTANT FILL MATERIALS IN CONJUNCTION WITH APPROPRIATELY RATED FIRE STOPPING SYSTEM. NON- FIRE-RATED WALLS SHALL USE ACOUSTICAL SEALANT. 17. EXTERIOR WALLS AND FIRE RESISTANCE RATED WALLS SHALL USE MINERAL WOOL INSULATION. NON-RATED WALLS REQUIRING SOUND ATTENUATION SHALL USE SOUND ATTENUATION BLANKETS. 18. RETURN GYP. BD. AND INTERIOR FINISHES INTO OPENINGS IN WALLS. 19. RETURN BRICK AT EACH EXTERIOR WALL OPENING. 20. FIRE PARTITIONS OF THE SAME FIRE RATING MAY HAVE A COMMON DRAFT-STOPPED CAVITY. FIRE BARRIERS MAY NOT SHARE A COMMON CAVITY WITH OTHER ASSEMBLIES AND UNINTERUPTED CONTINUITY OF THE FIRE BARRIER ASSEMBLY MUST BE MAINTAINED FOR THE FULL EXTENT OF THAT WALL. 21. SEE STRUCTURAL DRAWINGS FOR LOCATIONS WHERE ADDITIONAL LAYERS OF SHEATHING ARE REQUIRED. 22. FIRE RATED ASSEMBLIES ARE TO CONTAIN 5/8" TYPE-X GYP. BD. See Drawing A R C H I T E C T J O N A T H A N R . H E S S No. AR00890137 I N D I A N A R E G I S T E R E D STATE OF CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.bdmd.com Browning Day Mullins Dierdorf Architects Architecture Landscape Architecture Planning Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 3450 Founders Rd. Indianapolis, IN 46268 Phone: (317) 872-0540 www.zetataualpha.org Zeta Tau Alpha Fraternity Structural Engineer McComas Engineering MEP Engineer Circle Design Group 1717 East 116th St., Suite 200 Carmel, Indiana 46032 Phone: (317) 580-0402 www.mccomaseng.com 5510 S. East Street, Suite F Indianapolis, IN 46227 Phone: (317) 781-6200 www.circledesigngroup.com Interior Design 8/14/2017 1:56:39 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt A0.10 Wall Types 15A077 Author Checker August 7, 2017 Zeta Tau Alpha Headquarters 1036 S. Rangeline Road, Carmel, IN 100% Construction Documents REVISION SCHEDULE Rev. # Revision Description Issue Date 4 For Construction 8/7/2017 5 Revision #5 8/14/2017 CONSTRUCTION AND INSTALLATION REQUIREMENTS DEFINED BY THEIR DESIGNATED UL-ASSEMBLY. 3. SEE BUILDING CODE SUMMARY ON SHEET 0.01. 4. DIMENSIONS SHOWN ON THE LIFE SAFETY PLANS ARE FOR MEANS-OF-EGRESS / LIFE-SAFETY REFERENCE ONLY AND ARE NOT FOR CONSTRUCTION. CONTRACTOR IS TO UTILIZE PRECISE DIMENSIONS PROVIDED ON A1-SERIES DRAWINGS FOR FLOOR PLAN CONSTRUCTION DIMENSIONS. 5. MAXIMUM ALLOWABLE TRAVEL DISTANCE FOR ( R ) and ( M ) OCCUPANCIES IS 250'. PER IAC SECTION 1016. 7. DIMENSIONS LABELED AS "TRAVEL" INDICATE THE EXIT ACCESS DISTANCE ( TRAVEL DISTANCE ) FROM THE MIDPOINT BETWEEN TWO EXITS TO EITHER OF THE ASSOCIATED EXITS. 6. MAXIMUM ALLOWABLE TRAVEL DISTANCE FOR ( B ) OCCUPANCIES IS 300'. PER IAC SECTION 1016. CODED LIFE SAFETY NOTES 1-Hr RATED 2-Hr RATED 3-Hr RATED 1-HR RATED ASSM. SEE FLOOR PLANS AND WALL TYPES 2-HR RATED ASSM. SEE FLOOR PLANS AND WALL TYPES 3-HR RATED ASSM. SEE FLOOR PLANS AND WALL TYPES CODED NOTES OF VARYING TYPES: SEE SCHEDULES ON THIS SHEET SYMBOL LEGEND 1 FINISH DENOTES EXIT ACCESS / PATH OF EGRESS OCCUPANCY GROUP ROOM 101 E 150 42 20 1 NOMINAL SQ. FT. NUMBER OF EXITS REQUIRED OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS See Drawing A R C H I T E C T J O N A T H A N R . H E S S No. AR00890137 I N D I A N A R E G I S T E R E D STATE OF CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.bdmd.com Browning Day Mullins Dierdorf Architects Architecture Landscape Architecture Planning Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 3450 Founders Rd. Indianapolis, IN 46268 Phone: (317) 872-0540 www.zetataualpha.org Zeta Tau Alpha Fraternity Structural Engineer McComas Engineering MEP Engineer Circle Design Group 1717 East 116th St., Suite 200 Carmel, Indiana 46032 Phone: (317) 580-0402 www.mccomaseng.com 5510 S. East Street, Suite F Indianapolis, IN 46227 Phone: (317) 781-6200 www.circledesigngroup.com Interior Design 8/14/2017 1:56:38 PM \\xd-uem01\UserShare\hwilson\Documents\Revit Local\15077_ZTA\15A077_ZTA National Headquarters_for construction_HAW local.rvt A0.00-L Lower Level Life Safety Plan 15A077 Author Checker August 7, 2017 Zeta Tau Alpha Headquarters 1036 S. Rangeline Road, Carmel, IN 100% Construction Documents Floor Plan A0.00-L 1/8" = 1'-0" 1 Lower Level Life Safety Plan NORTH 0' 4' 8' 16' 32' REVISION SCHEDULE Rev. # Revision Description Issue Date 4 For Construction 8/7/2017 5 Revision #5 8/14/2017