Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Carmel [solidcore] G-A Sheets
26 34" CLR = 170 OCC. CAPACITY TRAVEL DISTANCE = 83'-0" ADJACENT TENANT SPACE SECONDARY EXIT NOT REQUIRED, BUT AVAILABLE EXISTING 1 HOUR RATED SEPARATION PARTITION CONTINUOUS BETWEEN TENANT SPACES - WITH ADDITIONAL SOUND PARTITION (TYPE 1) EXERCISE MACHINES 1 2 3 4 5 6 7 8 9 10 11 ADJACENT TENANT SPACE 26 TOTAL OCCUPANTS IN THIS SPACE EXTERIOR DOCK AREA EXISTING 1 HOUR RATED SEPARATION PARTITION CONTINUOUS BETWEEN TENANT SPACES - WITH ADDITIONAL SOUND PARTITION (TYPE 1) FE FE (A) FRONT APPROACH, PULL SIDE 60" MIN. 18" MIN. (C) HINGE APPROACH, PULL SIDE 60" MIN. 36" MIN. (B) FRONT APPROACH, PUSH SIDE 48" MIN. 12" MIN.* *IF BOTH CLOSER AND LATCH ARE PROVIDED (D) HINGE APPROACH, PUSH SIDE 54" MIN. 42" MIN. (E) HINGE APPROACH, PUSH SIDE 42" MIN.** 12" MIN.* *IF BOTH CLOSER AND LATCH ARE PROVIDED **48 MIN. IF BOTH CLOSER AND LATCH ARE PROVIDED 22" MIN. (F) LATCH APPROACH, PULL SIDE MILLWORK NOTES: I. MILLWORK SHALL BE FABRICATED AND INSTALLED BY A QUALIFIED WOODWORKER WITH EXPERIENCE IN COMMERCIAL APPLICATIONS SIMILAR IN SCOPE TO THE WORK. 2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CATALOGUE CUTS OF MILLWORK AND HARDWARE FOR REVIEW BY THE OWNER AND IN COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS. SHOP DRAWINGS SHALL SHOW THE DESIGN AND DIMENSIONS AND CLEARLY INDICATE AT A LARGE SCALE TO THE ARCHITECT THE METHOD AND MEANS OF CONSTRUCTION. FABRICATION OF MILLWORK SHALL NOT PROCEED UNTIL SHOP DRAWINGS HAVE BEEN APPROVED BY THE OWNER. 3. THE METHOD OF MANUFACTURING, FABRICATING AND INSTALLING MILLWORK, EQUIPMENT, AND ITS STRUCTURAL COMPONENTS DEFINED IN THE CONTRACT DOCUMENTS IS REPRESENTATIVE AND INDICATES DESIGN INTENT ONLY. IF THE MATERIALS, DETAILS OR DIMENSIONAL PROPERTIES ARE AT VARIANCE WITH THE CONTRACTOR'S OR MANUFACTURERS RECOMMENDATIONS, ALTERNATE DETAILS WILL BE CONSIDERED BY THE OWNER. MILLWORK AND EQUIPMENT SHALL HAVE PROPER SUPPORT, STABILITY AND FAULT-FREE PERFORMANCE. WORK SHALL CONFORM TO AMERICAN WOODWORKING INSTITUTE (AWl) STANDARDS FOR PREMIUM GRADE CONSTRUCTION. 4. MILLWORK COVERED WITH PLASTIC LAMINATE OR WOOD VENEER SHALL BE FABRICATED AND ASSEMBLED BY SKILLED WORKMEN TO THE SATISFACTION OF THE OWNER. EXPOSED SURFACES SHALL BE FREE FROM DENTS, TOOL MARKS, WARPAGE, BUCKING, OR OPEN JOINTS. JOINTS, CORNERS AND MITERED CONNECTIONS SHALL BE MADE TIGHTLY SO THAT EDGES ARE ENTIRELY CONCEALED. 5. CONTRACTOR SHALL OBTAIN ACCURATE FIELD MEASUREMENTS AND VERIFY DIMENSIONS TO ENSURE AN ACCURATE FIT. 6. FURNISH ALL NECESSARY HARDWARE TO COMPLETE THE WORK. UNSPECIFIED HARDWARE SHALL BE OF THE HIGHEST QUALITY AND DURABILITY. PROVIDE CATALOGUE CUTS OF HARDWARE FOR REVIEW BY THE OWNER. 7. INSTALL MILLWORK TO BE PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS NEEDED USING CONCEALED SHIMS. PROVIDE NEEDED BLOCKING AT NEW OR EXISTING CONSTRUCTION FOR INSTALLATION OF MILLWORK. 8. SCRIBE AND CUT MILLWORK TO FIT ADJOINING WORK. CAULK BACK-SPLASHES AT ALL PANTRY/ KITCHEN LOCATIONS. PROVIDE PLASTIC GROMMETS AT DESIGNATED PLASTIC LAMINATE CABINETRY AND COUNTERS FOR WIRE MANAGEMENT. SUBMIT CATALOGUE CUT SHEETS AND PROPOSED LOCATIONS TO ARCHITECT FOR APPROVAL. 9. EXPOSED ANCHORS, NAIL HEADS, SCREW HEADS, CHIPS, INDENTATIONS OR IMPERFECTIONS IN WOOD SURFACES TO BE PAINTED SHALL BE FILLED, SANDED, SEALED AND PREPARED FOR FINISHING. 10. WOOD CABINETS, COUNTERTOPS, TRIM AND RAILS ARE TO COMPLY WITH AWl SECTION 400 AND OTHER APPLICABLE AMERICAN WOODWORKING INSTITUTE STANDARDS (AWl) FOR CUSTOM GRADE. I I. LUMBER, PARTICLE BOARD, FINISH WOOD, PLYWOOD, BLOCKING, ETC. SHALL BE FIRE RETARDANT TREATED WHERE REQUIRED BY LOCAL BUILDING CODES, OR AS INTERPRETED BY THE LOCAL CODE OFFICIAL. 12. DELIVERED UNITS SHALL MATCH THE FINAL APPROVED SHOP DRAWINGS AND SAMPLES. WORK WHICH IS MARRED, CHIPPED OR OTHERWISE DAMAGED SHALL BE REPAIRED OR REPLACED AS DETERMINED BY THE OWNER. THE WORK SHALL BE PROTECTED DURING SHIPMENT AND INSTALLATION. AFTER INSTALLATION OF WORK IN PROPER LOCATION, PROTECTION SHALL BE REMOVED AND SURFACES THOROUGHLY CLEANED TO THE COMPLETE SATISFACTION OF THE OWNER. SURFACES SHALL THEN BE RECOVERED AND PROTECTED. 13. INSTALL MILLWORK IN COMPLIANCE WITH AWl SECTION 1700, PREMIUM GRADE UNLESS OTHERWISE INDICATED. FLUSH WOOD PANELING SHALL CONFORM TO AWl SECTION 500, PREMIUM. WOOD VENEER TO HAVE "AA" FACE. SEE DRAWINGS FOR SPECIES. VENEER SHALL BE BOOK MATCHED, BALANCE MATCH PANEL FACES AND SEQUENCE BETWEEN ADJACENT PANELS. EXPOSED EDGES TO BE VENEERED SAME SPECIES AND FINISH AS FACE. OWNER SHALL APPROVE VENEER FLITCHES PRIOR TO MANUFACTURE OF VENEER FACED MILLWORK. 14. TO THE GREATEST EXTENT POSSIBLE, FURNISH MILLWORK WITH SHOP APPLIED FINISHES. DEFER ONLY FINAL TOUCH-UP, CLEANING, AND POLISHING UNTIL AFTER INSTALLATION. SHOP APPLIED FINISHES SHALL COMPLY WITH AWl 1500, PREMIUM GRADE, TR-2 CATALY7ED A101 FLOOR PLAN 07.28.17 BID SET 1 2 3 4 5 6 7 8 9 10 11 6 A103 A 3'-0" 2" 7'-0" 7'-2" 3'-4" 2" HOLLOW METAL 1 3'-0" SOLID CORE WOOD 7'-0" KICKPLATE, BOTH SIDES. 2" PAINT P2 3 A103 4 A103 2 A103 5 A103 8 A103 ENTRY / RETAIL 100 TOILET 101 EXERCISE STUDIO 102 TOILET 103 STORAGE / UTILITY 104 7 A103 9 A103 101 EXIST. L A102 REFLECTED CEILING PLAN © 2017 daryl bachmeier, aia DRAWN BY: drb CHECKED BY: drb MARK PROJECT # : 1709-05 DATE DESCRIPTION CLAY TERRACE - BLDG C 14390 CLAY TERRACE BLVD - CARMEL, IN 1513 FIFTH STREET SOUTH FARGO, NORTH DAKOTA 58103 Email: drbach24@gmail.com Phone: 701-799-4025 [solidcore] (202) 517-6708 2298 Champlain St NW Washington, DC 20001 [solidcore] daryl bachmeier, ARCHITECT Unit C STATE OF AR11700074 D A R Y L R A Y B A C H M E I E R R E G I S T E R E D I N D I A N A A103 INTERIOR ELEVATIONS NOTES 18 45'-6" - VERIFY 10" 8'-0" @ MIRRORS 5 FINISH FLOOR TO STRUCTURE ABOVE - VERIFY 4 A.C.T. CEILING @ 11'-0" MIN. 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 5'-0" 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 2'-2" VERIFY 19'-5 1/2" - VERIFY WD1 FINISH FLOOR TO STRUCTURE ABOVE - VERIFY 10" CEILING @ 11'-0" MIN. 8'-0" @ MIRRORS © 2017 daryl bachmeier, aia DRAWN BY: drb CHECKED BY: drb MARK PROJECT # : 1709-05 DATE DESCRIPTION CLAY TERRACE - BLDG C 14390 CLAY TERRACE BLVD - CARMEL, IN 1513 FIFTH STREET SOUTH FARGO, NORTH DAKOTA 58103 Email: drbach24@gmail.com Phone: 701-799-4025 [solidcore] (202) 517-6708 2298 Champlain St NW Washington, DC 20001 [solidcore] daryl bachmeier, ARCHITECT Unit C STATE OF AR11700074 D A R Y L R A Y B A C H M E I E R R E G I S T E R E D I N D I A N A H I C R A E T T C 10" 8'-0" @ MIRRORS 19'-5 1/2" - VERIFY 3'-1" CLR. OPENING WD1 FINISH FLOOR TO STRUCTURE ABOVE - VERIFY CEILING @ 11'-0" MIN. 10" 8'-0" @ MIRRORS 10" 8'-0" @ MIRRORS - HOLD [solidcore] EQUAL EQUAL 8 7 07.28.17 BID SET 1'-0" 3'-6" 3'-4" 3'-0" MTPMRROAAOTDDEDEERULNINCAAUTLMMEBER K-CH_U2D86S3ONCALSATVATORY IRON 1'-0" 3'-0" 3'-0" 1'-4" 1'-6" 3'-4" D 4'-8" P1 WT1 A2 2'-10" 9'-0" 7'-3" - VERIFY 6'-7 3/4" - VERIFY 7" - 9" A3 14 WT1 P1 4'-0" @ WT1 16 A1 3'-4" 1'-6" 2'-0" C 9'-0" P1 7'-3" - VERIFY 13 B1 P2 12 P1 12 9'-0" 6'-7 3/4" - VERIFY 9'-0" B1 WC2 B 14 P1 P2 P2 7'-11 1/2" 15'-7 1/2" - VERIFY 7'-8" (@ TOILET RM. WALL) FINISH FLOOR TO STRUCTURE ABOVE - VERIFY 10'-0" B.O. SOFFIT A.F.F. 2 3 REF. 8 [solidcore] 7 WC1 WD1 WD1 8'-0" 6'-0" 5'-0" 2'-10" 4'-0" 14'-0" - VERIFY FINISH FLOOR TO STRUCTURE ABOVE - VERIFY @ OPN'G. FINISH FLOOR TO STRUCTURE ABOVE - VERIFY 9 P2 B1 5'-0" 17 3'-0" 7 WD1 B1 WD2 WD1 WD1 WRAP AROUND 7'-0 3/4" 12'-10 3/4" 19'-11 1/2" - VERIFY (@ TOILET ROOM WALL) VERIFY WD1 6'-7" (@ ENTRY / RETAIL ROOM WALL) 1'-0" 3'-0 1/4" CORNERS. 10'-0" A.F.F. TO B.O. SOFFIT P2 B1 10'-0" A.F.F. TO B.O. SOFFIT 11 11 7 2'-0" 1'-0" 3'-0" EQ. 5'-0" EQ. 7 11'-0" A.F.F. TO B.O. A.C.T. FINISH FLOOR TO STRUCTURE ABOVE - VERIFY 10'-0" A.F.F. TO B.O. SOFFIT 11'-0" A.F.F. TO B.O. A.C.T. OUTLINE OF EXERCISE EQUIPMENT - TYPICAL. 11'-0" A.F.F. TO B.O. A.C.T. P2 P2 P2 (ALSO @ EXISTING STOREFRONT WINDOW) 1 1 1 WD1 A B C D WD1 19'-11 1/2" - VERIFY 5'-0" 10'-0" A.F.F. 4'-0" 19 EQ. EQ. INT. ELEV. @ ENTRY / RETAIL 100 3 SCALE: 1/4" = 1'-0" INT. ELEV. @ ENTRY / RETAIL 100 2 SCALE: 1/4" = 1'-0" INT. ELEV. @ ENTRY / RETAIL 100 4 SCALE: 1/4" = 1'-0" INT. ELEV. @ ENTRY / RETAIL 100 5 SCALE: 1/4" = 1'-0" INTERIOR ELEVATIONS @ TOILET 101 (TOILET 103 SIMILAR OPPOSITE HAND) 1 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION @ STUDIO 102 6 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION @ STUDIO 102 7 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION @ STUDIO 102 8 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION @ STUDIO 102 9 SCALE: 1/4" = 1'-0" RESTROOM ACCESSORY SCHEDULE A1 TAG DESCRIPTION 42" GRAB BAR A2 36" GRAB BAR A3 18" GRAB BAR B MIRROR - 4'-8" HIGH, VERIFY WIDTH C TOILET PAPER DISPENSER (RECESSED) D LAVATORY PIPE INSULATION SINGLE SMALL ROLL MODEL # BOBRICK B-5806-42 BOBRICK B-5806-36 BOBRICK B-5806-18 PROVIDED & INSTALLED BY G.C. BOBRICK B-6677 LAVGUARD TRUEBRO 100 SERIES, GREY MOUNTING HEIGHTS 34" TO HORIZONTAL C.L. - MOUNT AT SIDE WALL OF WATER CLOSET, MOUNT VERTICAL. 40" A.F.F. TO CENTERLINE OF BRACKET. BOTTOM OF REFLECTIVE SURFACE AT 40" A.F.F. 24" A.F.F. AT CENTERLINE, 7" TO 9" CENTERLINE IN FRONT OF WATER CLOSET. INSTALL OVER HOT / COLD WATER AND DRAIN PIPES. 12" FROM CENTERLINE OF BRACKET TO BACK WALL. 34" TO HORIZONTAL C.L. - MOUNT AT BACK WALL OF WATER CLOSET, 6" FROM CENTERLINE OF BRACKET TO SIDE WALL. PLUG-IN SHELF DETAIL 10 SCALE: 1 1/2" = 1'-0" 1'-3" 1 1/2" 1'-0" WD1 WD1 2 X 4 FRT WOOD CLEAT 1/2" FRT PLYWOOD 4'-0" AFF 40" AFF RECEPTACLE LOCATION ENDS OPEN FOR ACCESSING OUTLETS 10 A103 VERIFY 1'-8" 2'-2" TYP. WC1 G.C.TO INSTALL 1/2" PLYWOOD OVER G.W.B. FROM FINISH FLOOR TO ROOF DECK THIS WALL AND TYP. ALL OTHER WALLS WITH PALLETWOOD G.C.TO INSTALL 1/2" PLYWOOD OVER G.W.B. FROM FINISH FLOOR TO INSTALL 2 LAYERS OF 5/8" GYP. BD. WITH GREEN GLUE BETWEEN - THIS ENTIRE WALL ROOF DECK THIS WALL AND TYP. ALL OTHER WALLS WITH PALLETWOOD 2'-0" HOLD 3'-0" MIN. - HOLD DRAWING NOTES - SHEET A103: 1 NOTE: SEE MECHANICAL, ELECTRICAL DRAWINGS FOR FIXTURES, FURNISHINGS, EQUIPMENT, UTILITIES, ETC. NOT SHOWN ON THIS PLAN - TYPICAL. 2 COUNTER FOR TOWELS BY G.C. COVER WITH WD1. CUT 8" DIAMETER HOLE FOR TOWEL DROP THROUGH COUNTER. 3 4 5 6 WD1 WALL FINISH WRAPPED AROUND WALL. SEE FINISH MATERIALS SCHEDULE / PLAN. 7 DASHED LINE INDICATES 2X FRT BLOCKING. COORDINATE FINAL LAYOUT WITH OWNER PRIOR TO BLOCKING INSTALLATION. 8 LOGO SIGN - TENANT FURNISHED AND CONTRACTOR INSTALLED. COORDINATE WITH TENANT. 9 HIGH - LOW WATER COOLER WITH BOTTLE FILL FUNCTION. SEE MECHANICAL. 10 TENANT PROVIDED APPAREL ROD. INSTALLED BY GENERAL CONTRACTOR. 11 TENANT PROVIDED SHELVING, INSTALLED BY GENERAL CONTRACTOR. 12 DOOR FRAME TO BE PAINTED P1. DOOR TO BE PAINTED P2. SEE FINISH MATERIALS SCHEDULE. 13 WALL MOUNT ELECTRIC HAND DRYER. MOUNT TO MEET CURRENT A.D.A. REQUIREMENTS. SEE ELECTRICAL. 14 CONTINUE TILE WT1 TO FINISH FLOOR. 15 16 1- 1 2" MIN. CLEARANCE REQUIRED BETWEEN FIXTURES AND GRAB BARS WHERE OCCUR - TYPICAL. 17 TENANT PROVIDED COAT RACK. INSTALLED BY G.C. 18 A.D.A. COMPLIANT TOILET - SEE MECHANICAL. 8'-0" HIGH MIRROR - TO BE MOUNTED WITH HIDDEN FASTENERS. GENERAL CONTRACTOR TO PROVIDE ALL. CONTRACTOR SHALL VERIFY WIDTH. MIRRORS TO BE MOUNTED TO INSURE SEAM IS SPACED BETWEEN FITNESS ROOM EQUIPMENT, NOT DIRECTLY IN FRONT OF EQUIPMENT. PROVIDE 1/16" GAP BETWEEN ALL MIRROR PANELS - TYPICAL. MOUNT BOTTOM OF MIRRORS 1'-0" ABOVE FINISH FLOOR. PAINT P2 ABOVE MIRRORS - TYPICAL. SEE FINISH MATERIALS SCHEDULE / PLAN. PAINT P1 BELOW MIRRORS - TYPICAL. SEE FINISH MATERIALS SCHEDULE / PLAN. UNDER-COUNTER REFRIGERATOR PROVIDED AND INSTALLED BY G.C. VERIFY SIZE WITH OWNER. TENANT-PROVIDED CUBBIES. 19 INSTRUCTOR PLUG-IN. G.C. TO PROVIDE AND INSTALL A 12" DEEP, 30" WIDE SHELF AT 48" A.F.F. G.C. TO COVER SHELF IN PALLET WOOD. G.C. TO COORDINATE SHELF LOCATION WITH TENANT AND A/V EQUIPMENT, AND INSTALL BLOCKING IN WALL CAVITY TO SUPPORT. SEE DETAIL 10/A103. FINISH MATERIALS SCHEDULE TAG MATERIAL / FINISH CON1 B1 EXISTING CONCRETE P1 P2 P3 P4 WC1 WC2 DESCRIPTION WALL BASE WALL PAINT ACCENT PAINT EXPOSED CEILING PAINT CEILING PAINT WALL COVERING WALL COVERING MANUFACTURER LUMISEAL FX SEALANT N + SHERWIN WILLIAMS FLAVOR PAPER FLAVOR PAPER WD1 PALLET WOOD SALVAGED WOOD WT1 WALL TILE T.B.D. SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS FINISH / PATTERN GLOSSY COAT 4" STRAIGHT SW7005 DAUPHINE PARTY GIRL FACTORY APPLIED HIGH / LOW SPLIT FACE SW6243 SW6243 SW7005 FIRE TREATMENT COLOR GRAY BLACK PURE WHITE BYWATER BLUE ELECTRIC NATURAL T.B.D. DISTANCE DISTANCE PURE WHITE FINISH RASPBERRY LOCATION / REMARKS ROLLED GOODS ONLY. EGGSHELL TYP. - EPOXY AT TOILET RMS EGGSHELL FLAT FLAT PROVIDED AND INSTALLED BY G.C. RECLAIMED WOOD PALLET, PROVIDED AND INSTALLED BY G.C. INSTALLED BY G.C. INSTALLED BY G.C. ON RESTROOM WET WALL AND ADJACENT TOILET WALL. G.C. TO PROVIDE $6/SF MATERIAL ALLOWANCE FOR TILE. WD2 SLATWALL AAADISPLAYS ACRYLIC MIRROR - PROVIDED BY TENANT, INSTALLED BY G.C. 20 EXISTING ELECTRICAL PANEL TO REMAIN - SEE ELECTRICAL. ADHERE PALLETWOOD TO PANEL COVER AND DOOR FACE WITH PALLETWOOD TO MATCH WALL SURFACE. LEAVE PANEL COVER SCREWS ACCESSIBLE FOR COVER REMOVAL. P2 48'-2" - VERIFY 10" 8'-0" @ MIRRORS 5 FINISH FLOOR TO STRUCTURE ABOVE - VERIFY 4 A.C.T. CEILING @ 11'-0" MIN. 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 5'-0" 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 3'-10" 15 4'-10" VERIFY P1 P2 OUTLINE OF EXERCISE EQUIPMENT - TYPICAL. VERIFY 2'-2" 1'-8" TYP. INSTALL 2 LAYERS OF 5/8" GYP. BD. WITH GREEN GLUE BETWEEN - THIS ENTIRE WALL 2'-0" HOLD 2'-2" 1'-8" TYP. B1 WD2 WD1 P1 H I C R A E T T C 07.28.17 BID SET DRAWING NOTES - SHEET A102: 1 NOTE: SEE MECHANICAL, ELECTRICAL DRAWINGS FOR FIXTURES, FURNISHINGS, EQUIPMENT, UTILITIES, ETC. NOT SHOWN ON THIS PLAN - TYPICAL. FRAME GYPSUM BOARD CEILING WITH 6" METAL STUD CEILING JOISTS @ 16" O.C. THIS ROOM. REFLECTED CEILING PLAN GENERAL NOTES: 1. HEIGHT OF CEILINGS SHALL BE MEASURED FROM FINISH FLOOR TO FINISH FACE OF CEILING AS INDICATED ON THE REFLECTED CEILING PLAN, UNLESS NOTED OTHERWISE. 2. BORDERS AT LAY-IN ACOUSTIC CEILING SHALL BE CUT AND FINISHED TO MATCH FACTORY EDGE PROFILE. 3. DIMENSIONED LIGHT FIXTURES ARE FROM FINISHED FACE OF PARTITIONS TO CENTERLINE OF FIXTURE AND FROM CENTERLINE OF FIXTURE TO CENTERLINE OF FIXTURE. AT LAY-IN CEILINGS, FIXTURES SHALL BE INSTALLED IN CENTERLINE OF CEILING TILE UNLESS NOTED OTHERWISE. 4. DISCREPANCIES WITH LIGHT FIXTURES, SWITCHES, THERMOSTATS, AND / OR DIFFUSERS AS TO LOCATIONS BETWEEN VARIOUS DRAWINGS OR BETWEEN THE DRAWINGS AND EXISTING FIELD CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT BEFORE PROCEEDING WITH INSTALLATION. EXACT LOCATIONS SHALL BE IDENTIFIED BY THE CONTRACTOR AND VERIFIED BY THE ARCHITECT PRIOR TO INSTALLATION. 5. NO EXPOSED FASTENERS SHALL BE PERMITTED, INCLUDING POP RIVETS AND TAPPETS. 6. NO CEILING TILES SHALL BE CUT TO LESS THAN 3" WIDTH WITHOUT ARCHITECT'S APPROVAL. CONTRACTOR SHALL NOTIFY ARCHITECT IF GRID PLACEMENT WILL CAUSE TILES TO BE UNDERSIZE. 7. SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF ASTM C 635 AND ASTM C 636 (IBC 808.1.1). 8. ALL CEILING FINISHES SHALL BE CLASS A (FLAME SPREAD INDEX 0-25, SMOKE DEVELOPED INDEX 0-450) WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723; OR, SHALL COMPLY WITH IBC 803.1.2.1 WHEN TESTED IN ACCORDANCE WITH NFPA 286 OR OTHERWISE DEMONSTRATE COMPLIANCE WITH IBC 803.11.2. 9. METAL FRAMING FOR GYPSUM WALL BOARD CEILING SHALL CONSIST OF 1-1/2" COLD ROLLED STEEL CHANNELS AT 4'-0" O.C. SUSPENDED BY 8 GAUGE GALVANIZED WIRE HANGERS SPACED 4'-0" O.C. WITH 7/8" , 25 GAUGE METAL FURRING STRIPS RUNNING PERPENDICULAR TO CHANNELS AT 2'-0" O.C., ATTACHED TO CHANNELS WITH APPROVED CLIPS. ALTERNATE SYSTEMS MAY BE USED IF REVIEWED WITH ARCHITECT PRIOR TO CONSTRUCTION. ACT-1 CEILING SPECIFICATION (2 PIECE ASSEMBLY) CEILING TILE 'A' (EXPOSED FACE) CERTAINTEED - PERFORMA THEATRE BLACK F TYPE: XII SIZE: 24 x 24 x 5/8" EDGE: TRIM (SQUARE) SURFACE: LAMINATED, BLACK CORE: FIBERGLASS RECYCLED CONTENT: 33% CEILING TILE 'B' (INSTALL ON TOP OF CEILING TILE 'A') CETAINTEED - PERFORMA BAROQUE TYPE: III SIZE: 24 x 24 x 5/8" EDGE: TRIM (SQUARE) SURFACE: WHITE CORE: MINERAL FIBER RECYCLED CONTENT: 33% SUSPENSION SYSTEM 15/16" CLASSIC STAB, INTERMEDIATE DUTY, HEAVY DUTY PER ASTM C635. FLANGE: 15/16" COLOR: BLACK MAIN RUNNERS: 12' CROSS TEES: 4', 12' EDGE MOLDING: ANGLE ANCHORS SUFFICIENT FOR FIVE TIMES DESIGN LOAD PER ASTM C635. WIRE FOR HANGERS OF SIZE AND TYPE TO SUIT INTENDED APPLICATION PER ASTM C641. PERFORMANCE CRITERIA FOR 2-PIECE CEILING TILE ASSEMBLY: NOISE REDUCTION COEFFICIENT (NRC) : 0.75 (FOR 2-PIECE ASSEMBLY). LIGHT REFLECTANCE (LR): PER ASTM E1477. CEILING ATTENUATION CLASS (CAC): 40 (FOR 2-PIECE ASSEMBLY). FLAME SPREAD CLASSIFICATION PER ASTM E84: CLASS A. THIRD PARTY VERIFIED TYPE I ENVIRONMENTAL LABEL - PER ISO 14024. EXISTING STRUCTURE, FIELD VERIFY A.F.F. 5/8" GYPSUM WALL BOARD. 1/2" FRT PLYWOOD. WD1 WALL FINISH MATERIAL. DIAGONAL BRACING AS REQUIRED. 3-5/8" METAL STUD SOFFIT FRAMING @ 24" O.C. METAL CORNER BEAD, TYPICAL AT ALL CORNERS. 5/8" GYPSUM WALL BOARD. 1/2" FRT PLYWOOD. WD1 WALL FINISH MATERIAL. CEILING AS SCHEDULED, SEE R.C.P. ALL MECHANICAL WALL PENETRATIONS TO BE SEALED WITH ACOUSTICAL SEALANT AND WRAPPED IN ABSORPTIVE MATERIAL. ALL SHARED DUCTWORK IN THE STUDIO SPACE TO BE ROUND WHERE POSSIBLE, S-SHAPED BENDS WHERE POSSIBLE AND BE LINED WHERE POSSIBLE. ALL DUCTWORK IN THE STUDIO SHOULD BE ROUND WHERE POSSIBLE AND WRAPPED WITH ABSORPTIVE MATERIAL AND LINED TO MINIMIZE SOUND TRANSMISSION. REFLECTED CEILING PLAN LEGEND: NOTE: SEE MECHANICAL AND ELECTRICAL DRAWING SHEETS FOR ADDITIONAL FIXTURES NOT SHOWN ON THIS PLAN - TYPICAL. 1' x 4' CEILING LIGHT FIXTURE @ 9'-0" A.F.F. (VERIFY). SEE ELECTRICAL. TRACK LIGHT FIXTURE @ 9'-6" A.F.F. (VERIFY). SEE ELECTRICAL. PENDANT LIGHT FIXTURE @ 9'-6" A.F.F. (VERIFY). SEE ELECTRICAL. PENDANT LIGHT FIXTURE @ 9'-6" A.F.F. (VERIFY). SEE ELECTRICAL. RECESSED CAN LIGHT. SEE ELECTRICAL. EXIT SIGN. SEE ELECTRICAL. EXIT SIGN. SEE ELECTRICAL. EMERGENCY LIGHT FIXTURE. SEE ELECTRICAL. LAY-IN CEILING DIFFUSER. SEE MECHANICAL. LAY-IN CEILING RETURN AIR GRILLE. SEE MECHANICAL. HVAC DIFFUSER. SEE MECHANICAL. VENTILATION FAN WITH LIGHT. SEE MECHANICAL. 2 SUSPENDED LED TRACK LIGHTING. SEE ELECTRICAL. 3 SUSPENDED LED PENDANT LIGHT. SEE ELECTRICAL. 4 SUSPENDED FLUORESCENT LIGHT. SEE ELECTRICAL. 5 RECESSED CAN LIGHT AT SOFFIT. SEE ELECTRICAL. 6 LED EMERGENCY EXIT LIGHT FIXTURE. SEE ELECTRICAL. 7 1 2 2 3 TYP. 5 5 6 7 7 7 7 8 HVAC DIFFUSER. SEE MECHANICAL. WALL MOUNT LED EMERGENCY LIGHT FIXTURE. SEE ELECTRICAL. A.C.T.-1 11'-0" A.F.F. A.C.T.-1 11'-0" A.F.F. WD1 SOFFIT 10'-0" A.F.F. WD1 SOFFIT 10'-0" A.F.F. EXISTING VERIFY A.F.F. B.O. SOFFIT SEE R.C.P. B.O. CEILING SEE R.C.P. DIMENSION PER PLAN 6" EXISTING STRUCTURE, FIELD VERIFY A.F.F. 5/8" GYPSUM WALL BOARD. 1/2" FRT PLYWOOD. WD1 WALL FINISH MATERIAL. DIAGONAL BRACING AS REQUIRED. 3-5/8" METAL STUD SOFFIT FRAMING @ 24" O.C. METAL CORNER BEAD, TYPICAL AT ALL CORNERS. 5/8" GYPSUM WALL BOARD. 1/2" FRT PLYWOOD. WD1 WALL FINISH MATERIAL. B.O. SOFFIT SEE R.C.P. B.O. CEILING SEE R.C.P. DIMENSION PER PLAN 2" AIR SPACE, MINIMUM. 6" 18 GA. METAL STUDS @ 16" O.C. 6" UNFACED SOUND BATT INSULATION. 2 LAYERS OF 5/8" TYPE 'X' GYPSUM WALL BOARD WITH JOINTS STAGGERED. INSTALL WITH 2 TUBES OF GREEN GLUE PER SHEET OF GYPSUM WALL BOARD SANDWICHED BETWEEN LAYERS. EXISTING TENANT SEPARATION WALL. FIELD VERIFY CONSTRUCTION. GWB (P4) 9'-0" A.F.F. 3 A103 2 A102 7 8 TYP. 8 TYP. North NOTE: SHADING REPRESENTS LANDLORD/ADJACENT TENANT AREA. 8 3 101 102 REFLECTED CEILING PLAN 1 SCALE: 1/4" = 1'-0" SOFFIT DETAIL 2 SCALE: 1-1/2" = 1'-0" SOFFIT DETAIL 3 SCALE: 1-1/2" = 1'-0" 6 EXISTING VERIFY A.F.F. 1 2 2 2 3 4 5 6 7 7 7 7 7 7 7 7 7 7 7 8 8 11 11 13 12 15 16 1 A103 C A B D © 2017 daryl bachmeier, aia DRAWN BY: drb CHECKED BY: drb MARK PROJECT # : 1709-05 DATE DESCRIPTION CLAY TERRACE - BLDG C 14390 CLAY TERRACE BLVD - CARMEL, IN 1513 FIFTH STREET SOUTH FARGO, NORTH DAKOTA 58103 Email: drbach24@gmail.com Phone: 701-799-4025 [solidcore] (202) 517-6708 2298 Champlain St NW Washington, DC 20001 [solidcore] daryl bachmeier, ARCHITECT Unit C STATE OF AR11700074 D A R Y L R A Y B A C H M E I E R R E G I S T E R E D I N D I A N A H I C R A E T T C 17 WC 9 9 1'-8" 2'-0" TYP. 3'-0" HOLD 2'-2" 14'-0" +/- 7 1/4" 2" AIR 6'-7 3/4" 5" 6'-2 1/2" 1'-3" 3'-0 3/4" 2'-4 3/4" SPACE MIN. 10 5 EX. E.P. W.H. North TYPE DOOR AND FRAME SCHEDULE DOOR WIDTH SIZE HEIGHT THICK. MAT. FINISH. FRAME MAT. TYPE DOOR NOTES 101 1-3/4" SCWD 1 H.M. A FINISH P1 NO. 3'-0" 7'-0" P2 SOLID CORE WOOD DOOR HEIGHT A.F.F. N. WALL CEILING ROOM FINISH SCHEDULE ROOM NAME FLOORING BASE E. WALL S. WALL W. WALL CEILING NOTES: NO. ROOM 100 101 ABBREVIATIONS: G.B. = GYPSUM BOARD P1 / P2 / P3 / P4 ENTRY / RETAIL AREA = PAINT 103 104 STORAGE / UTILITY 102 STUDIO FRP = FIBERGLASS REINFORCED PANEL B1 = RUBBER BASE CON1 = LUMISEAL FX OVER ARDEX CON1 WC2 = WALL COVERING TOILET WARE HARD- 1 HARDWARE GROUP 1: HINGES: 1 1/2 PAIR; MCKINNEY - T4A3386. LOCKSET: PRIVACY; SARGENT 11 LINE LEVER - B, ROSE P LEVER - 619 SATIN NICKEL FINISH. DOOR STOP: FLOOR; ROCKWOOD - 441H - 619 SATIN NICKEL FINISH. KICKPLATE: (1) EACH SIDE OF DOOR. ROCKWOOD - K1050 - 619 SATIN NICKEL FINISH. GENERAL DOOR NOTES: 1. PROVIDE (3) SILENCERS (GRAY COLOR) FOR SINGLE DOOR FRAME AND (6) SILENCERS FOR DOUBLE DOOR FRAMES. 2. CLOSER AND OTHER HARDWARE SHALL MEET THE REQUIREMENTS OF A.D.A. REGULATIONS. 3. ALL HARDWARE ALLOWS FREE EGRESS IN THE DIRECTION OF EGRESS. 4. ALL ACCESS CONTROLLED EGRESS DOORS TO BE EQUIPPED WITH APPROVED ENTRANCE AND EGRESS ACCESS CONTROL SYSTEM TO COMPLY WITH IBC 1008.1.9.8. 5. UNDERCUT DOORS AS REQUIRED - SEE MECHANICAL DRAWINGS. B1 11'-0"+ 1., 2., 3. WT1/B1 EXIST. / P4 8'-0" --- - -- - 4. ACT1 11'-0" + 2. WD1/WD2 P2/WD1/WD2 WC1 P1 ACT1 B1 WT1/P1 WC2 P1 WT1/P1 - - - P1 / P2 WD1 P1 / P2 WD1 WD1 = PALLET WOOD WD2 = SLATWALL ACT1 = ACOUSTIC CEILING TILE WC1 = WALL COVERING REFER TO FINISH MATERIALS PLAN AND SCHEDULE FOR MORE DETAILED MATERIAL INFORMATION. CON1 EXIST. CON1 DOOR ELEVATION 2 SCALE: 1/4" = 1'-0" NOTE: SHADING REPRESENTS LANDLORD/ADJACENT TENANT AREA. NOTES: 1. PALLETWOOD AROUND WALL BUMP-OUTS. 2. RAISE SUSPENDED CEILING AS HIGH AS POSSIBLE. ALLOW ENOUGH SPACE FOR DUCTWORK, RECESSED CEILING ITEMS, ETC. 3. PAINT DRYWALL P1 AREAS EXPOSED ABOVE AND BELOW STOREFRONT. 4. NO NEW FINISHES THIS ROOM. TOILET CON1 WT1/B1 WT1/P1 WT1 / P1 P1 WC2 G.B. / P4 9'-0" EX. / EXIST. = EXISTING FRAME ELEVATION 3 SCALE: 1/4" = 1'-0" FLOOR PLAN 1 SCALE: 1/4" = 1'-0" EXIST. EXIST. 14 DEMOLITION PLAN 4 SCALE: 1/8" = 1'-0" FINISHES PLAN 5 SCALE: 1/8" = 1'-0" GENERAL DEMOLITION NOTES - SHEET A101: A NOTE: SEE MECHANICAL, ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS, NOTES, ETC. NOT SHOWN ON THIS PLAN - TYPICAL. EXISTING FLOOR TILE TO REMAIN THROUGHOUT SPACE AND USED AS THE FINISH FLOORING IN LOBBY AND RESTROOMS, TILE TO BE COVERED WITH NEW RUBBER FLOORING IN EXERCISE STUDIO. B REMOVE EXISTING CEILING GRID, TILE, TREATMENTS THROUGHOUT SPACE WITH THE EXCEPTION OF THE EXISTING TOILET ROOM AND STORAGE / UTILITY ROOM CEILINGS. C REMOVE EXISTING CEILING SOFFITS AT THIS LOCATION. C C C C D REMOVE EXISTING DOOR AND DOOR FRAME COMPLETE AT THIS LOCATION. E REMOVE EXISTING INTERIOR PARTITION COMPLETE AT THIS LOCATION. PATCH FLOOR W/ ARDEX LEVEL W/ EXISTING TILE TO REMAIN. E E E E E D B E A A A A C C 17 10 8" 7 1/4" 19'-5 1/2" AIR SPACE 2" AIR SPACE MIN. 7 1/4" P2 P1 RB1 B1 P2 P1 WD1 WD1 WD1 EXIST. B1 WC1 WD1 P1/WT1 P1 WC2 - A103 C A B D EX. E.P. WD2 P2 WD1 DRAWING NOTES - SHEET A101: 1 NOTE: SEE MECHANICAL, ELECTRICAL DRAWINGS FOR FIXTURES, FURNISHINGS, EQUIPMENT, UTILITIES, ETC. NOT SHOWN ON THIS PLAN - TYPICAL. G.C. TO PROVIDE MAG LOCK TYPE DOOR HARDWARE ON EXISTING ENTRY DOOR. G.C. TO INSTALL DOOR BUZZER NOTIFICATION SYSTEM THAT HAS MAG LOCK OPENING FEATURE INSTALLED AT RECEPTION DESK. COORDINATE EXACT SYSTEM REQUIREMENTS WITH TENANT. SEE ELECTRICAL DRAWINGS. 2 CUBBIES PROVIDED BY TENANT. VERIFY SIZE AND QUANTITY WITH TENANT. 3 TENANT PROVIDED COAT RACK, INSTALLED BY G.C. ALSO SEE DETAIL 4/A103. 4 FURNITURE PROVIDED BY TENANT. VERIFY LOCATIONS WITH TENANT. 5 LOGO SIGN - TENANT FURNISHED AND CONTRACTOR INSTALLED. G.C. TO COORDINATE WITH TENANT TO DETERMINE HEIGHT AND LOCATION. ALSO SEE DETAILS 5/A103 AND 10/A103. 6 G.C. TO INSTALL TENANT PROVIDED APPAREL SHELVING / APPAREL HANGING SYSTEM, SLATWALL PANELS - ACRYLIC MIRROR - WITH ACCESSORIES. 7 DASHED LINES INDICATE TENANT PROVIDED FITNESS EQUIPMENT. MANUFACTURER: SWEATLANA. G.C. TO ASSEMBLE AND INSTALL. 14 TOTAL (VERIFY). 8 WALL MOUNTED STUDIO MIRRORS ACROSS ENTIRE LENGTH OF WALL. MIRRORS TO BE CENTERED ON FITNESS EQUIPMENT @ 3'-8" O.C. (VERIFY). JOINTS IN MIRRORS TO OCCUR AT MIDPOINT BETWEEN EQUIPMENT. 9 10 WALL MOUNTED MIRRORS ACROSS ENTIRE LENGTH OF THIS WALL. SEE SHEET G002. 11 EXISTING ELECTRICAL PANEL - SEE ELECTRICAL. ADHERE PALLETWOOD TO PANEL COVER AND DOOR FACE WITH PALLETWOOD TO MATCH WALL SURFACE. LEAVE PANEL COVER SCREWS ACCESSIBLE FOR COVER REMOVAL. 12 SOUND RACK BY VENDOR - SEE ELECTRICAL. 13 TENANT PROVIDED TOWEL CART. 14 EXISTING MOP SINK AND NEW WATER HEATER. SEE MECHANICAL. 15 INSTRUCTOR PLUG-IN. G.C. TO PROVIDE AND INSTALL A 12" DEEP, 30" WIDE SHELF AT 48" A.F.F. G.C. TO COVER SHELF IN PALLET WOOD. G.C. TO COORDINATE SHELF LOCATION WITH TENANT AND A/V EQUIPMENT, AND INSTALL BLOCKING IN WALL CAVITY TO SUPPORT. SEE DETAIL 11/A103. 16 UNDER-COUNTER REFRIGERATOR BY G.C. - MANUFACTURER: DANBY MODEL # DBC 120BLS STAINLESS STEEL. 17 PROVIDE AND INSTALL ELECTRIC HAND DRYER. HAND DRYER - MODEL # XLERATOR XL, COLOR STAINLESS STEEL WITH XLERATOR 895 WALL GUARD. SEE ELECTRICAL. COVER BACK OF NEW WALL FRAMING WITH PRE-FINISHED SHEET METAL TO MATCH STOREFRONT FRAME COLOR. FIELD VERIFY. FINISH MATERIALS SCHEDULE TAG MATERIAL / FINISH CON1 B1 EXISTING CONCRETE P1 P2 P3 P4 WC1 WC2 DESCRIPTION WALL BASE WALL PAINT ACCENT PAINT EXPOSED CEILING PAINT CEILING PAINT WALL COVERING WALL COVERING MANUFACTURER LUMISEAL FX SEALANT N + SHERWIN WILLIAMS FLAVOR PAPER FLAVOR PAPER WD1 PALLET WOOD SALVAGED WOOD WT1 WALL TILE T.B.D. SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS FINISH / PATTERN GLOSSY COAT 4" STRAIGHT SW7005 DAUPHINE PARTY GIRL FACTORY APPLIED HIGH / LOW SPLIT FACE SW6243 SW6243 SW7005 FIRE TREATMENT COLOR GRAY BLACK PURE WHITE BYWATER BLUE ELECTRIC NATURAL T.B.D. DISTANCE DISTANCE PURE WHITE FINISH RASPBERRY LOCATION / REMARKS ROLLED GOODS ONLY. EGGSHELL TYP. - EPOXY AT TOILET RMS. EGGSHELL FLAT FLAT PROVIDED AND INSTALLED BY G.C. RECLAIMED WOOD PALLET, PROVIDED AND INSTALLED BY G.C. INSTALLED BY G.C. INSTALLED BY G.C. ON RESTROOM WET WALL AND ADJACENT TOILET WALL. G.C. TO PROVIDE $6/SF MATERIAL ALLOWANCE FOR TILE. 18 INSTALL UNI-STRUT CHANNEL FACING UP, RUNNING DOWN THE CENTER OF STUDIO, 6" ABOVE CEILING GRID. USE KINETICS NOISE CONTROL CEILING HANGER MODEL ICC OR SIMILAR. NOTE: DIMENSIONS SHOWN ARE FROM OUTSIDE FACE OF WALL FINISH TYPICAL. WD2 SLATWALL AAADISPLAYS ACRYLIC MIRROR - PROVIDED BY TENANT, INSTALLED BY G.C. HOLD 19'-0" BETWEEN MIRRORS 2'-0" 1'-0" 1'-0" 5'-3" 2'-2" 19 18 VERIFY EXACT LOCATION OF EXISTING COLUMN - NOTIFY ARCHITECT IF COLUMN IS NOT WHERE INDICATED. 22 F EXISTING WALLS, DOORS, CEILING AND FLOORING TO REMAIN IN-PLACE THIS AREA. F G WT1 = CERAMIC TILE RB1 RUBBER FLOORING AMARCO STYLE-FLECK - 3/8" THICK 604 PROVIDED AND INSTALLED BY G.C. 45'-6" COUNTER FOR TOWELS BY G.C. COVER WITH WD1. CUT CIRCULAR OPENINGS AT COUNTER TOP FOR TOWEL DROP. UNDER-COUNTER RECEPTACLE FOR TOWELS PROVIDED AND INSTALLED BY TENANT. A.D.A. COMPLIANT HIGH - LOW WATER COOLER WITH BOTTLE FILL FUNCTION. SEE MECHANICAL. 19 20 21 22 20 G REMOVE EXISTING TOILET, WALL-MOUNTED LAVATORY, GRAB BARS, WALL TILE, LIGHT FIXTURES, SHELVING, ETC. COMPLETE AT THIS TOILET ROOM. COORDINATE WITH M & E. 23 WALLS TO BE PATCHED WITH DRYWALL, OR TILE BACKER BOARD AT NEW WALL TILE, WHERE EXISTING WALL TILE IS REMOVED AT THIS EXISTING TOILET ROOM. 23 WD1 3'-4 5" 1 2" 11" P1/WT1 P1 WC2 P1 LACQUER. 15. ALL CABINETS SHALL BE OF FLUSH OVERLAY CONSTRUCTION UNLESS OTHERWISE NOTED OR DETAILED WITH 4" SATIN CHROME WIRE PULLS U.O.N. INTERIOR SURFACES OF CABINETS NOT EXPOSED TO VIEW SHALL BE WHITE MELAMINE WITH PLASTIC LAMINATE EDGE BANDING TO MATCH DOORS. ALL CABINET EXTERIOR SURFACES EXPOSED TO VIEW SHALL BE PLASTIC LAMINATE. CABINET DOORS TO BE PLASTIC LAMINATE AS SPECIFIED AT ALL FACES AND EDGES. ALL OPEN SHELVING SHALL BE PLASTIC LAMINATE. 16. COMPOSITE WOOD, AS DEFINED BY THE CALIFORNIA AIR RESOURCES BOARD, AIRBORNE TOXIC MEASURE TO REDUCE FORMALDEHYDE EMISSIONS FROM COMPOSITE WOOD PRODUCTS REGULATION, MUST BE DOCUMENTED TO HAVE LOW FORMALDEHYDE EMISSIONS THAT MEET THE CALIFORNIA AIR RESOURCES BOARD ATCM FOR FORMALDEHYDE REQUIREMENTS FOR ULTRA-LOW-EMITTING FORMALDEHYDE (ULEF) RESINS OR NO ADDED FORMALDEHYDE RESINS. FLOOR FINISH NOTES: I. G.C. TO CLEAN EXISTING CONCRETE SLAB. APPLY COAT WITH ADDED GRIT FOR SLIP RESISTANCE ON ALL CONCRETE FLOORS. 2. USE ROLL GOODS ONLY FOR VINYL BASE. UNROLL VINYL BASE 24 HOURS PRIOR TO INSTALLATION TO ALLOW VINYL TO LOSE MEMORY. 3. PROVIDE PROTECTION FOR FLOOR DURING CONSTRUCTION AND MOVE-IN AFTER INSTALLATION. 4. INTERIOR FLOOR FINISH MATERIALS SHALL COMPLY WITH DOC FF-I "PILL TEST" (CSPC I G CFR PART I (30) OR ASTM D 285fJ. WALL FINISH NOTES: I. UNLESS OTHERWISE INDICATED, INTERIOR WALL FINISHES SHALL BE CLASS C (FLAME SPREAD INDEX 7G-200, SMOKE-DEVELOPED INDEX 0-450) OR BETTER WHEN TESTED IN ACCORDANCE WITH ASTM E B4 OR UL 723; OR SHALL COMPLY WITH IBC 803.1.2 WHEN TESTED IN ACCORDANCE WITH NFPA 28G. 2. FINISHES NOT APPLIED DIRECTLY TO NON-COMBUSTIBLE CONSTRUCTION SHALL COMPLY WITH IBC 803.11.1 OR IBC 803.11.2 OR DEMONSTRATE COMPLIANCE WITH IBC 803. 11. 3. G.W.B. SOFFITS TO BE PAINTED P4, U.N.O. 4. DECORATIVE WOOD PALLET WALL (WD I). APPLY FLAME STOP, INC., FLAME STOP /I (OR EQUIVALENT MANUFACTURER WITH EQUAL TESTING" RATING) TO WOOD PLANKS AND FRAME PRIOR TO INSTALLATION TO ENSURE A MINIMUM CLASS A RATING FOR FIRE RESISTANCE. APPLICATION SHALL BE CONDUCTED IN CONTROLLED ENVIRONMENT AND THOROUGHLY DOCUMENTED. REFERENCE FLAME STOP /I SPECIFICATIONS FOR ADDITIONAL INFORMATION AND APPLICATION PROCEDURES. PRESENT BOTH DOCUMENTATION AND SPEC INFORMATION ON-SITE TO BE VISIBLE AT ALL TIMES. INTERIOR DRYWALL FINISH NOTES: I. GYPSUM WALL BOARD INSTALLATION SHALL CONFORM TO ASTM C840, THE RECOMMENDATIONS OF THE GYPSUM ASSOCIATION, THE SPECIFIC RECOMMENDATIONS OF THE MANUFACTURER, AND THE REQUIREMENTS OF THE UL FIRE RESISTANCE DIRECTORY (AT FIRE RATED PARTITIONS). APPLY TAPE AND JOINT COMPOUND OVER JOINTS, INTERIOR ANGLES, FASTENER HEADS, METAL TRIMS, AND ACCESSORIES IN COMPLIANCE WITH LEVELS OF GYPSUM BOARD FINISH AS INDICATED IN GYPSUM ASSOCIATION PUBLICATION 214. 2. MECHANICAL, ELECTRICAL, AND PLUMBING PENETRATIONS IN FIRE RATED PARTITIONS SHALL BE FIRE-STOPPED AT THEIR PERIMETER WITH APPROVED FIRE-STOPPING MATERIALS. MECHANICAL, ELECTRICAL, AND PLUMBING PENETRATIONS IN SOUND RATED PARTITIONS SHALL BE SEALED AT THEIR PERIMETER WITH APPROVED ACOUSTICAL SEALER. 3. GYPSUM WALL BOARD SHALL BE FINISHED TO WITHIN 1/4" OF FLOOR SLAB AT PARTITIONS TO RECEIVE BASE. 4. PARTITIONS ARE DIMENSIONED TO FACE OF GYPSUM WALLBOARD, UNLESS OTHERWISE NOTED. DIMENSIONS INDICATED AS "CLEAR' OR "CLR' SHALL BE MAINTAINED. DISCREPANCIES OR VARIATIONS IN THESE DIMENSIONS SHALL BE REVIEWED WITH THE ARCHITECT BEFORE BEGINNING CONSTRUCTION. HORIZONTAL DIMENSIONS INDICATED ARE TO / FROM FACE OF GYPSUM WALLBOARD UNLESS NOTED OTHERWISE. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB EXCEPT WHERE NOTED TO BE ABOVE FINISHED FLOOR. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT APPROVAL OF ARCHITECT. 5. PARTITIONS, EDGE TRIM, CORNER BEADS, PRE-FORMED REVEALS AND JOINTS TO EXISTING GYPSUM WALL BOARD SURFACES SHALL BE TAPED, BEDDED IN JOINT COMPOUND AND SANDED SMOOTH WITH NO VISIBLE JOINTS. "J" TRIM SHALL NOT BE USED. PROVIDE BACKING FOR REVEALS AS RECOMMENDED BY MANUFACTURER. 6. OUTSIDE CORNERS OF GYPSUM WALL BOARD SHALL HAVE METAL CORNER BEADS (SCREWED TYPE), UNLESS NOTED OTHERWISE. 7. CONTROL JOINTS SHALL BE INSTALLED IN UNBROKEN PARTITIONS EXCEEDING 30 FEET. CONTROL JOINTS SHALL BE INSTALLED IN UNBROKEN CEILING PLANES EXCEEDING 50 FEET. CONTROL JOINTS IN FIRE RATED PARTITIONS SHALL CONFORM TO THOSE TESTED IN COMPLIANCE WITH ASTM E I 19. 8. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL RELATIVE TO THE CEILING PLANE, AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANE. 9. PARTITION TYPES ABOVE DOORS AND WINDOWS SHALL BE SAME AS THE ADJACENT PARTITIONS, UNLESS NOTED OTHERWISE. 10. PREFORMED METAL WALL REVEALS IF NOT SPECIFICALLY INDICATED ON DRAWINGS SHALL BE EITHER PITTCON INDUSTRIES MODEL #STR-050-050 1/2" CHANNEL OR PITTCON INDUSTRIES MODEL #SWR-050-050 1/2" (OR APPROVED EQUAL) CHANNEL AS NEEDED BY APPLICATION. 11. AS REQUIRED, PARTITIONS AND DOOR JAMBS ARE TO BE BRACED TO THE UNDERSIDE OF STRUCTURE ABOVE. 12. WALL SURFACES, GYPSUM WALL BOARD, CEILINGS, METAL FRAMES, AND TRIM SHALL BE PAINTED, UNLESS NOTED OTHERWISE. REFER TO WALL FINISH PLANS, ELEVATIONS AND FINISH SCHEDULE FOR TYPE AND EXTENT OF WALL FINISHES. 13. SURFACES TO BE PAINTED SHALL BE PREPARED FOR PRIMING IN COMPLIANCE WITH THE WALL FINISH MANUFACTURERS' RECOMMENDATIONS. 14. PAINTED SURFACES SHALL RECEIVE I PRIME AND 2 FINISH COATS OF SCHEDULED PAINT. ALL PAINT AND PRIMERS ARE TO BE LOW VOC. 15. ALL PAINTS AND COATINGS WET-APPLIED ON SITE MUST MEET THE APPLICABLE VOC LIMITS OF THE CALIFORNIA AIR RESOURCES BOARD (CARB) 2007, SUGGESTED CONTROL MEASURE (SCM) FOR ARCHITECTURAL COATINGS, OR THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1 1 13, EFFECTIVE JUNE 3, 2011. 16. ALL ADHESIVES AND SEALANTS WET-APPLIED ON SITE MUST MEET THE APPLICABLE CHEMICAL CONTENT REQUIREMENTS OF SCAQMD RULE 1 1 68, JULY 1, 2005, ADHESIVE AND SEALANT APPLICATIONS, AS ANALYZED BY THE METHODS SPECIFIED IN RULE 1 1 68. THE PROVISIONS OF SCAQMD RULE 1 1 68 DO NOT APPLY TO ADHESIVES AND SEALANTS SUBJECT TO STATE OR FEDERAL CONSUMER PRODUCT VOC REGULATIONS. PARTITION NOTES : 1. INSTALLATION OF INTERIOR GYPSUM WALL BOARD METAL FRAMING SYSTEMS SHALL CONFORM TO ASTM C754 2. VERIFY BLOCKING REQUIREMENTS WITH MILLWORK SUBCONTRACTOR PRIOR TO INSTALLATION. 3. METAL FRAMING SHALL NOT BE ATTACHED TO DUCTWORK. 4. CONTRACTOR SHALL CUT AND PATCH EXISTING BASE BUILDING CORE WALLS AS REQUIRED FOR INSTALLATION OF NEW TELEPHONE DATA OR ELECTRICAL OUTLETS OR EQUIPMENT. COMPLY WITH U.L. DESIGN GUIDELINES WHEN CUTTING AND PATCHING RATED PARTITIONS. 5. ALL PENETRATIONS TO BE SEALED WITH ACOUSTIC SEALANT, FIRE-CAULKED AT RATED PARTITIONS. ANCHOR TRACK TO STRUCTURE ABOVE. 1/2" MIN. CLEAR, TOP OF STUD TO TRACK. SLOTTED TOP TRACK ATTACHED TO STUDS. INSTALL SCREWS AT CENTERED IN SLOT WITH STAND OFF WASHERS. 5/8" GYPSUM WALL BOARD BOTH SIDES. 3-5/8 25 GA. CFS C-SHAPED STUDS @ 16" O.C. WITH SOUND BATT INSULATION. 25 GA. CFS BOTTOM TRACK ATTACHED WITH ANCHORS @ 24" O.C. MAX. WALL BASE AND FINISH FLOORING AS SCHEDULED. 2 3 1/2" MIN. CLEAR, TOP OF STUD TO TRACK. SLOTTED TOP TRACK ATTACHED TO STUDS. INSTALL SCREWS AT CENTERED IN SLOT WITH STAND OFF WASHERS. 5/8" GYPSUM WALL BOARD BOTH SIDES. 6" 18 GA. METAL STUDS @ 16" O.C. WITH UN-FACED SOUND BATT INSULATION. 18 GA. METAL STUD TRACK ATTACHED WITH ANCHORS @ 24" O.C. MAX. WALL BASE AND FINISH FLOORING AS SCHEDULED. ACOUSTIC SEALANT TYPICAL ALL PERIMETER JOINTS. WALLMAT (KINETICS). KAI-S ANCHOR INSULATOR BUSHING (KINETICS). 6" 18 GA. SLOTTED TOP TRACK, ATTACHED TO STUDS. INSTALL SCREWS CENTERED IN SLOT WITH STAND OFF WASHERS. 2 LAYERS OF 5/8" TYPE 'X' GYPSUM WALL BOARD WITH JOINTS STAGGERED. INSTALL WITH 2 TUBES OF GREEN GLUE PER SHEET OF GYPSUM WALL BOARD SANDWICHED BETWEEN LAYERS. 2" AIR SPACE. 6" 18 GA. METAL STUDS @ 16" O.C. 6" ROXUL SAFE 'N SOUND MINERAL WOOL INSULATION. ACOUSTIC SEALANT TYPICAL ALL PERIMETER JOINTS. WALLMAT (KINETICS). KAI-S ANCHOR INSULATOR BUSHING (KINETICS). 6" 18 GA. METAL STUD TRACK, ATTACHED WITH ANCHORS AT 24" O.C. TENANT SEPARATION WALL BY LANDLORD. VERIFY CONSTRUCTION TYPE AND MATERIALS: 5/8" GYP. BD./6" ST. STUDS/ MINERAL WOOL INSULATION. FLOOR STRUCTURE VERIFY ELEVATION - TYPICAL. VERIFY ELEVATION - TYPICAL. VERIFY ELEVATION - TYPICAL. FINISH FLOOR AS SCHEDULED. EXIST. FLOOR SLAB. VERIFY ELEVATION - TYPICAL. WT1 WALL FINISH AT TOILET ROOMS. SEE FINISH MATERIALS SCHEDULE. PARTITION AS SCHEDULED. SEE PLAN. 40" - VERIFY LED LIGHT FIXTURE TO BE INSTALLED CONTINUOUS WITH MIRRORS. SEE ELECTRICAL DRAWINGS. LED LIGHT FIXTURE TO BE INSTALLED CONTINUOUS WITH MIRRORS. SEE ELECTRICAL DRAWINGS. PAINT P1 ABOVE MIRROR. SEE FINISH MATERIALS SCHEDULE. CEILING AS SCHEDULED. MIRROR PROVIDED AND INSTALLED BY G.C. MOUNT MIRROR TO CLEAT WITH HIDDEN FASTENERS. CLEATS BY G.C. WALL BASE AND FINISH FLOOR AS SCHEDULED. VERIFY ELEVATION - TYPICAL. PAINT P1 BELOW MIRROR. PARTITION AS SCHEDULED. SEE PLAN. 10" - VER. LED LIGHT FIXTURE TO BE INSTALLED CONTINUOUS WITH MIRRORS. SEE ELECTRICAL DRAWINGS. LED LIGHT FIXTURE TO BE INSTALLED CONTINUOUS WITH MIRRORS. SEE ELECTRICAL DRAWINGS. PAINT P2 ABOVE MIRROR. SEE FINISH MATERIALS SCHEDULE. CEILING AS SCHEDULED - AS HIGH AS PRACTICAL. MIRROR PROVIDED AND INSTALLED BY G.C. MOUNT MIRROR TO CLEAT WITH HIDDEN FASTENERS. CLEATS BY G.C. TOILET ROOMS MIRROR STUDIO MIRROR EXIST. FLOOR SLAB. EXIST. FLOOR SLAB. EXIST. FLOOR SLAB. EXIST. FLOOR SLAB. 0'-0" (VERIFY) 0'-0" (VERIFY) 0'-0" (VERIFY) 0'-0" (VERIFY) 0'-0" (VERIFY) 3A GYPSUM BOARD ONE SIDE. ANCHOR TRACK TO STRUCTURE ABOVE. SLOTTED TOP TRACK ATTACHED TO STUDS. INSTALL SCREWS AT CENTERED IN SLOT WITH STAND OFF WASHERS. 3-5/8 25 GA. CFS C-SHAPED STUDS @ 16" O.C. WITH SAFE 'N SOUND ROXUL MINERAL INSUL. 4 VERIFY ELEVATION - TYPICAL. EXIST. FLOOR SLAB. 0'-0" (VERIFY) 2 LAYERS OF 5/8" TYPE 'X' GYPSUM WALL BOARD WITH JOINTS STAGGERED. INSTALL WITH 2 TUBES OF GREEN GLUE PER SHEET OF GYPSUM WALL BOARD SANDWICHED BETWEEN LAYERS. ACOUSTIC SEALANT TYPICAL AT ALL ACOUSTIC SEALANT TYPICAL CEILING AS SCHEDULED PERIMETER JOINTS. ALL PERIMETER JOINTS BY LANDLORD. SLOTTED TOP TRACK ACOUSTIC SEALANT TYPICAL ALL PERIMETER JOINTS BY LANDLORD. TENANT SEPARATION WALL BY LANDLORD. VERIFY CONSTRUCTION TYPE AND MATERIALS: 5/8" GYP. BD./6" ST. STUDS/ MINERAL WOOL INSULATION. ADJACENT TENANT SOLIDCORE SPACE PARTITION TYPES 1 SCALE: 1/4" = 1'-0" WALLMAT (KINETICS). KAI-S ANCHOR INSULATOR BUSHING (KINETICS). ACOUSTIC SEALANT TYPICAL ALL PERIMETER JOINTS. WALLMAT (KINETICS). KAI-S ANCHOR INSULATOR BUSHING (KINETICS). 25 GA. CFS BOTTOM TRACK ATTACHED WITH ANCHORS AT 24" O.C. CLEATS BY G.C. ACOUSTIC SEALANT TYPICAL ALL PERIMETER JOINTS. ACOUSTIC SEALANT TYPICAL ALL PERIMETER JOINTS. EXISTING 1 HR RATED FLOOR STRUCTURE EXISTING 1 HR RATED FLOOR STRUCTURE EXISTING 1 HR RATED FLOOR STRUCTURE EXISTING 1 HR RATED FLOOR STRUCTURE EXISTING 1 HR RATED FLOOR STRUCTURE EXISTING 1 HR RATED UNDER-SLAB UTILITIES STUBBED INTO SPACE BY LANDLORD TYP., EXTENSION OF UTILITIES REQUIRED TO NEW LOCATIONS ALONG WITH ASSOCIATED CONCRETE SLAB SAWCUTTING/REPLACEMENT TO BE BY TENANT'S CONTRACTORS 1 UL DESIGN NO. U466 - 1 HOUR RATED STC = 70 © 2017 daryl bachmeier, aia DRAWN BY: drb CHECKED BY: drb MARK PROJECT # : 1709-05 DATE DESCRIPTION CLAY TERRACE - BLDG C 14390 CLAY TERRACE BLVD - CARMEL, IN 1513 FIFTH STREET SOUTH FARGO, NORTH DAKOTA 58103 Email: drbach24@gmail.com Phone: 701-799-4025 [solidcore] (202) 517-6708 2298 Champlain St NW Washington, DC 20001 [solidcore] daryl bachmeier, ARCHITECT Unit C S T A T E O F AR11700074 D A R Y L R A Y B A C H M E I E R R E G I S T E R E D I N D I A N A H I C R A E T T C NOTES PARTITION TYPES G002 07.28.17 PLAN REVIEW SET 48" MIN.* 24" MIN. (G) LATCH APPROACH, PUSH SIDE 24" MIN. *54 MIN. IF CLOSER IS PROVIDED 42" MIN. VIEWERS/SIGNAGE KICK PLATE PUSH PLATES, HANDLES & PUSH BARS DEAD BOLTS C L B MAXIMUM FORWARD REACH OVER AN OBSTRUCTION A. FORWARD REACH TO WALL MOUNTED OBJECTS BABY CHANGING STATION HC PHONE PROVIDE WOOD BLOCKING IN WALL AT MOUNTING POINTS OF ACCESSORIES TYPICAL AT COIN SLOT HC MOUNTING HEIGHT MIN. GRAB BAR WC 19" MIN FE1 CAB WC URINAL AT TOP OF CABINET FE 1'-4" 2'-11" 4'-0" 4'-0" 33" MIN - 36" MAX 17" MIN 3'-0" 6" 3'-0" 1'-6" 3'-4" 1'-6" 4'-0" 3'-6" 3'-1" 3'-6" 1'-5" 2'-10" 19" MIN. 3'-0" 7" 1 1/2" CLR 2'-8" 3'-6" 3'-0" 1'-0" 3'-4" 4" 3'-0" 1'-6" 4'-0" 15" MIN 4'-0" 17"-19" 4'-0" 2'-6" 2'-6" 1'-6" 1'-6" 9" 5'-0" 4'-0" 3'-2" 11" WALL MOUNTED LAVATORY MAXIMUM SIDE REACH OVER AN OBSTRUCTION 3'-6" COAT HOOK PURSE SHELF 9" 4'-6" 10" 2'-6" MAX. C MAXIMUM HIGH AND LOW REACH 4'-5" MIRROR 3'-4" TO BOTTOM OF REFLECTING SURFACE ELECTRIC HAND DRYER NOTE: GENERAL HEIGHT REFERENCE ONLY - SOME OF THESE ITEMS ARE NOT APPLICABLE TO THIS PROJECT 4'-0" (MIN.) CLEAR FRONT ELEV. SIDE ELEV. 2'-6" TO BUBBLER 3'-0" TO RIM ELECTRIC WATER COOLER/ DRINKING FOUNTAIN VICINITY AND LOCATION MAP NORTH CLAY TERRACE LOCATION 1 A101 [solidcore] LIFE SAFETY PLAN LEGEND EXIT SIGN WITH DIRECTIONAL ARROW XX EXIT TRAVEL DISTANCE TD = XX' AND OCCUPANT LOAD FE FIRE EXTINGUISHER (VERIFY LOCATIONS W/ LOCAL FIRE MARSHALL) SUITE IN BUILDING C OF CLAY TERRACE - TOTAL TRAVEL DISTANCE = 83' PROJECT INFO G001 07.28.17 PLAN REVIEW SET FIRE / SPRINKLER NOTES © 2017 daryl bachmeier, aia DRAWN BY: drb CHECKED BY: drb MARK PROJECT # : 1709-05 DATE DESCRIPTION CLAY TERRACE - BLDG C 14390 CLAY TERRACE BLVD - CARMEL, IN 1513 FIFTH STREET SOUTH FARGO, NORTH DAKOTA 58103 Email: drbach24@gmail.com Phone: 701-799-4025 [solidcore] (202) 517-6708 2298 Champlain St NW Washington, DC 20001 [solidcore] daryl bachmeier, ARCHITECT Unit C S T A T E O F AR11700074 D A R Y L R A Y B A C H M E I E R R E G I S T E R E D I N D I A N A H I C R A E T T C SUITE LOCATION WITHIN BUILDING C OF CLAY TERRACE NORTH CLAY TERRACE - BUILDING C 14390 CLAY TERRACE BLVD - CARMEL, IN GENERAL G001 PROJECT INFORMATION G002 NOTES, PARTITION TYPES ARCHITECTURAL A101 FLOOR PLAN, DOOR SCHEDULE A102 REFLECTED CEILING PLAN A103 INTERIOR ELEVATIONS, NOTES MECHANICAL M001 MECHANICAL LEGEND, SCHEDULES M002 MECHANICAL SPECIFICATIONS M003 MECHANICAL SPECIFICATIONS M101 MECHANICAL PLANS ELECTRICAL E001 ELECTRICAL SYMBOLS, LEGEND E101 REFLECTED CEILING PLAN LIGHTING E201 FLOOR PLAN POWER E301 ELECTRICAL SCHEDULES, DETAILS