Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
JGH007_MCKENZIE_AS-DESIGNED
BUILDING FILE REPORT File Name: JGH007_MCKENZIE_CODE.blg Date: August 11, 2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Property/Builder: Organization Building Name: JGH007 Org. Name: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Address: P.O. BOX 705 Property Address: 478 SIMON DR City, St, Zip: CARMEL, IN 46082 City, St, Zip: CARMEL (AS DESIGNED), IN 46032 Phone No: 317-846-4655 Phone No: Website: www.tsienergysolutions.com Builder's Name: HOMES BY McKENZIE, INC Rater's Name: MICHAEL HILL Phone No: 317-574-8806 Rater's Email: mhill@tsienergysolutions.com Email Address: jmckenzie1@johnmckenziecollection.com Rater's ID: 9479271 Model: GROSMONT Provider ID: 1998-053 Development: HAMLET @ JACKSON'S GRANT 7 Sample Set ID: 0000 Permit Date/Number: Rating Date: 08-10-2017 Rating Type: Projected Rating Reason: New Home Rating No.: Registry ID: Verifier's Name: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name: Verifier's ID: BUILDING FILE REPORT JGH007 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. General Building Information Area of Cond. Space(sq ft): 3336 Volume of Cond. Space: 39603 Year Built: 2017 Housing Type: Single-family detached Level Type(Apartments Only): None Floors on or Above-Grade: 2 Number of Bedrooms: 2 Foundation Type: Slab Enclosed Crawl Space Type: N/A Number of Stories Including Conditioned Basement: 2 Thermal Boundary Location: N/A Slab Floor Info: 1 Name SLAB Library Type R-10, 1'down, 3' in Area(sq ft) 2243 Depth Below Grade(ft) 0.0 Full Perimeter(ft) 278 Exposed Perimeter(ft) 278 On-Grade Perimeter(ft) 278 Slab Floor: R-10, 1'down, 3' in Slab Covering Carpet Perimeter Insulation (R-Value): 10.0 Perimeter Insulation Depth (ft): 1.0 Under-Slab Insulation (R-Value): 10.0 Under-Slab Insulation Width (ft): 3.0 Slab Insulation Grade: 1 Radiant Slab: No Note: Floor Info: 1 2 Name OVER GARAGE OVER AMB Library Type GR-1 R-30 GR-1 R-30 Area (sq ft) 17 55 Location Btwn cond & ambient Btwn cond & ambient Uo Value 0.035 0.035 BUILDING FILE REPORT JGH007 Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Floor: GR-1 R-30 Information From Quick Fill Screen: Continous Insulation R-Value 0.0 Cavity Insulation R-Value 30.0 Cavity Insulation Thickness (in.) 9.5 Cavity Insulation Grade 1.0 Joist Size (w x h, in) 1.5 x 9.5 Joist Spacing (in oc) 16.0 Framing Factor - (default) 0.1300 Floor Covering CARPET Note: Layers Paths Cavity Framing Grade Inside Air Film 0.920 0.920 0.920 Floor covering 1.230 1.230 1.230 Subfloor 0.820 0.820 0.820 Cavity ins 30.000 0.000 0.000 Continuous ins 0.000 0.000 0.000 Framing 0.000 11.875 0.000 0.000 0.000 0.000 Outside Air Film 0.455 0.455 0.455 Total R-Value 33.425 15.300 3.425 U-Value 0.030 0.065 0.292 Relative Area 0.870 0.130 0.000 UA 0.026 0.008 0.000 Total Component UA: 0.035 Total Component Area: 1.0 Component Uo: 0.035 BUILDING FILE REPORT JGH007 Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Rim and Band Joist: 1 2 Name COND/AMB COND/ATTIC Area(sq ft) 91.0 33.0 Continuous Ins 0.5 0.5 Framed Cavity Ins 15.0 15.0 Cavity Ins Thk(in) 3.5 3.5 Joist Spacing 16.0 16.0 Insulation Grade 1 1 Location Cond -> ambient Cond -> attic Uo Value 0.061 0.061 Above-Grade Wall: 1 2 3 Name COND/AMB COND/AMB 2X6 COND/GAR Library Type G1 R-15 BATT, OSB G1 R-19, OSB 2x6 G1 R-15 Gar Walls Gross Area(sq ft) 2530.00 1393.00 380.00 Exterior Color Medium Medium Dark Location Cond -> ambient Cond -> ambient Cond -> garage Uo Value 0.076 0.058 0.076 Above-Grade Wall: 4 5 Name COND/GAR 2X6 COND/ATTIC Library Type G1 R-19, 2x6 GAR G1 R-15 BATT, OSB Gross Area(sq ft) 120.00 130.00 Exterior Color Dark Dark Location Cond -> garage Cond -> attic Uo Value 0.058 0.076 BUILDING FILE REPORT JGH007 Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-15 BATT, OSB Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 15.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 15.000 4.375 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 17.740 7.115 3.770 U-Value 0.056 0.141 0.265 Relative Area 0.770 0.230 0.000 UA 0.043 0.032 0.000 Total Component UA: 0.076 Total Component Area: 1.0 Component Uo: 0.076 BUILDING FILE REPORT JGH007 Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-19, OSB 2x6 Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 19.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1988 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 19.000 6.875 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 21.740 9.615 3.770 U-Value 0.046 0.104 0.265 Relative Area 0.801 0.199 0.000 UA 0.037 0.021 0.000 Total Component UA: 0.058 Total Component Area: 1.0 Component Uo: 0.058 BUILDING FILE REPORT JGH007 Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-15 Gar Walls Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 15.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 1.0 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.900 0.900 0.900 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 15.000 4.375 1.030 Continuous ins 0.000 0.000 0.000 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 17.690 7.065 3.720 U-Value 0.057 0.142 0.269 Relative Area 0.770 0.230 0.000 UA 0.044 0.033 0.000 Total Component UA: 0.076 Total Component Area: 1.0 Component Uo: 0.076 BUILDING FILE REPORT JGH007 Page 8 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-19, 2x6 GAR Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 19.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1988 Gypsum Thickness (in) 1.0 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.900 0.900 0.900 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 19.000 6.875 1.030 Continuous ins 0.000 0.000 0.000 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 21.690 9.565 3.720 U-Value 0.046 0.105 0.269 Relative Area 0.801 0.199 0.000 UA 0.037 0.021 0.000 Total Component UA: 0.058 Total Component Area: 1.0 Component Uo: 0.058 BUILDING FILE REPORT JGH007 Page 9 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 1 2 3 Name FRONT 2X6 FRONT 2X4 FRONT 2X6 GD Library Type U-.29, SHGC-.27 U-.29, SHGC-.27 U-.29, SHGC-.27 U-Value 0.290 0.290 0.290 SHGC 0.270 0.270 0.270 Area(sq ft) 144.00 10.00 24.00 Orientation North North North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 2 AGWall 1 AGWall 2 Window Information: 4 5 6 Name BACK 2X6 BACK LEFT SIDE 2X6 Library Type U-.30, SHGC-.26 U-.30, SHGC-.26 U-.29, SHGC-.27 U-Value 0.300 0.300 0.290 SHGC 0.260 0.260 0.270 Area(sq ft) 37.00 16.00 74.00 Orientation South South East Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 2 AGWall 1 AGWall 2 BUILDING FILE REPORT JGH007 Page 10 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 7 8 9 Name LEFT SIDE RIGHT SIDE 2X6 RIGHT SIDE Library Type U-.29, SHGC-.27 U-.29, SHGC-.27 U-.29, SHGC-.27 U-Value 0.290 0.290 0.290 SHGC 0.270 0.270 0.270 Area(sq ft) 204.00 30.00 30.00 Orientation East West West Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 2 AGWall 1 Window: U-.29, SHGC-.27 U-Value: 0.290 Solar Heat Gain Coefficient: 0.270 Note: Window: U-.30, SHGC-.26 U-Value: 0.300 Solar Heat Gain Coefficient: 0.260 Note: Door Information: 1 2 Name FRONT GARAGE Opaque Area(sq ft) 30.0 24.0 Library Type Steel-urth w/brk Steel-urth w/brk Wall Assignment AGWall 2 AGWall 4 Uo Value 0.187 0.187 Door: Steel-urth w/brk R-Value of Opaque Area: 4.4 Storm Door: No Note: BUILDING FILE REPORT JGH007 Page 11 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Roof Information: 1 Name MAIN Library Type R-50, Attic GR1 Ceiling Area(sq ft) 2315.00 Roof Area(sq ft) 2315.00 Color Medium Radiant Barrier No Type(Attic) Attic Uo Value 0.020 Clay or Cement Tiles: No Sub Roof Ventilation: No BUILDING FILE REPORT JGH007 Page 12 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Ceiling: R-50, Attic GR1 Information From Quick Fill Screen: Continous Insulation (R-Value) 37.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Attic Note: Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.450 0.450 0.450 Cavity Ins/Frm 4.375 13.000 0.000 Continuous ins 37.000 37.000 37.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.610 0.610 0.610 Total R-Value 43.045 51.670 38.670 U-Value 0.023 0.019 0.026 Relative Area 0.110 0.890 0.000 UA 0.003 0.017 0.000 Total Component UA: 0.020 Total Component Area: 1.0 Component Uo: 0.020 BUILDING FILE REPORT JGH007 Page 13 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Skylight Information: 1 Name MEDIA ROOM SKYLIGHT Library Type U-.31, SHGC-.32 U-Value 0.310 SHGC 0.320 Area(sq ft) 64.0 Winter Shading None Summer Shading None Orientation South Pitch[?/12] 2 Ceiling Assignment Roof 1 Window: U-.31, SHGC-.32 U-Value: 0.310 Solar Heat Gain Coefficient: 0.320 Note: Mechanical Equipment: General Number of Mechanical Systems: 3 Heating SetPoint(F): 68.00 Heating Setback Thermostat: Present Cooling SetPoint(F): 78.00 Cooling Setup Thermostat: Present Heat: 912SA48060S14 SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 58.0 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 528 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 100 Number Of Units: 1 BUILDING FILE REPORT JGH007 Page 14 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Cooling Equipment: 13ACX-048-230 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 48.0 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 100 Number Of Units: 1 Water Heating Equipment: NAVIEN CR-240A Water Heater Type: Instant water heater Fuel Type: Natural gas Energy Factor: 0.98 Recovery Efficiency: 0.00 Water Tank Size (gallons): 0 Extra Tank Insulation (R-Value): 0.0 Note: Location: Garage or open crawl space Percent Load Served: 100 Performance Adjustment: 100 Number Of Units: 1 DHW Efficiencies All bath faucets & showers <= 2gpm: false All DHW pipes fully insulated >= R-3: false Recirculation type: None (standard system) Farthest fixture to DHW heater 80 TOTAL Pipelength for longest DHW run: 100 DWHR unit present?: false BUILDING FILE REPORT JGH007 Page 15 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct System Information: Name MAIN Heating System 912SA48060S14 Cooling System 13ACX-048-230 Supply Area(sq ft) 675.5 Return Area(sq ft) 500.4 Conditioned Floor Area(sq ft) 3336.0 # of Registers 4 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 198.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 264.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 1 2 3 Type Supply Return Supply Percent Area 5.0 50.0 95.0 R-Value 30.0 30.0 6.0 Location Attic, under insulation Attic, under insulation Conditioned space Duct Information: 4 Type Return Percent Area 50.0 R-Value 6.0 Location Conditioned space BUILDING FILE REPORT JGH007 Page 16 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type: Blower door test Heating Season Infiltration Value: 5.00 ACH @ 50 Pascals Cooling Season Infiltration Value: 5.00 ACH @ 50 Pascals Shelter Class 4 Code Verification: Tested Mechanical Ventilation for IAQ Type: None Rate(cfm): 0 Sensible Recovery Efficiency(%): 0.00 Total Recovery Efficiency(%): 0.00 Hours per Day: 24.00 Fan Power (watts): 0.00 ECM Fan Motor: false Ventilation Strategy for Cooling Cooling Season Ventilation: Natural Ventilation Lights and Appliances Simplified Audit Refrigerator KWh: 673 Refrigerator Location: Conditioned Dishwasher EF: 0.46 Dishwasher kWh/yr: 0 Dishwasher Capacity: 12 Dishwasher kWh/Year: 0 Range/Oven Fuel Type: Electric Induction Range: No Convection Oven: No Clothes Dryer Fuel Type: Electric Clothes Dryer Location: Conditioned Clothes Dryer Moisture Sensing: No Clothes Dryer Energy Factor: 3.01 Clothes Dryer Gas Energy Factor: 2.67 Clothes Washer Location: Conditioned Clothes Washer LER: 704.0 Clothes Washer MEF: 0.817 Clothes Washer Capacity: 2.874 Clothes Washer Electricity Rate: 0.08 BUILDING FILE REPORT JGH007 Page 17 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Lights and Appliances Clothes Washer Gas Rate: 0.58 Clothes Washer Annual Gas Cost: 23.00 Percent CFLs: 0.0 Percent Fluorescent: 10.0 Percent Exterior Lights: 0.0 Percent Garage Lights: 0.0 Ceiling Fan CFM / Watt: 0.00 Mandatory Requirements IECC Requirements Verified IECC 04: true Verified IECC 06: true Verified IECC 09: true Verified IECC 12: false Verified IECC 15: false Verified NY-ECCC 2010: false Verified Michigan: false Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist (National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Refrigerators: 0 Ceiling Fans: 0 Exhaust Fans: 0 Dishwashers: 1 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grade: false Basement Floor Area: 0 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist: false EPA Field App ID ENERGY CODE INSPECTION CHECKLIST Date: August 11, 2017 Rating No.: Building Name: JGH007 Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Phone No.: 317-846-4655 Property: 478 SIMON DR Rater's Name: MICHAEL HILL Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 9479271 Builder's Name: HOMES BY McKENZIE, INC Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: JGH007_MCKENZIE_CODE.blg Rating Date: 08-10-2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Building Information: Conditioned Area (sq ft): 3336 Conditioned Volume (cubic ft): 39603 Insulated Shell Area (sq ft): 9307 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TSI ENERGY SOLUTIONS's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings: [ ] 1. Attic: R-50, Attic GR1 (2315 s.f.) R-37.0 continuous insulation, R-13.0 cavity insulation. Name: MAIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Above-Grade Walls: [ ] 1. Wall: G1 R-15 BATT, OSB (2530 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: G1 R-19, OSB 2x6 (1393 s.f.), Between conditioned space and ambient ENERGY CODE INSPECTION CHECKLIST JGH007 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/AMB 2X6 Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Wall: G1 R-15 Gar Walls (380 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-15.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 4. Wall: G1 R-19, 2x6 GAR (120 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-19.0 cavity insulation. Name: COND/GAR 2X6 Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 5. Wall: G1 R-15 BATT, OSB (130 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Windows and Skylights: Window-to-Wall Area Ratio: 0.12 [ ] 1. Window: U-.29, SHGC-.27 (144 s.f., North), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: FRONT 2X6 Orientation: North Comments/Location___________________________________________________________ [ ] 2. Window: U-.29, SHGC-.27 (10 s.f., North), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: FRONT 2X4 Orientation: North Comments/Location___________________________________________________________ [ ] 3. Window: U-.29, SHGC-.27 (24 s.f., North), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: FRONT 2X6 GD Orientation: North ENERGY CODE INSPECTION CHECKLIST JGH007 Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ [ ] 4. Window: U-.30, SHGC-.26 (37 s.f., South), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK 2X6 Orientation: South Comments/Location___________________________________________________________ [ ] 5. Window: U-.30, SHGC-.26 (16 s.f., South), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK Orientation: South Comments/Location___________________________________________________________ [ ] 6. Window: U-.29, SHGC-.27 (74 s.f., East), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: LEFT SIDE 2X6 Orientation: East Comments/Location___________________________________________________________ [ ] 7. Window: U-.29, SHGC-.27 (204 s.f., East), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: LEFT SIDE Orientation: East Comments/Location___________________________________________________________ [ ] 8. Window: U-.29, SHGC-.27 (30 s.f., West), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: RIGHT SIDE 2X6 Orientation: West Comments/Location___________________________________________________________ [ ] 9. Window: U-.29, SHGC-.27 (30 s.f., West), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: RIGHT SIDE Orientation: West Comments/Location___________________________________________________________ [ ] 10. Skylight: U-.31, SHGC-.32 (64 s.f.), U-Value: 0.310, SHGC: 0.320 For skylights without labeled U-factors, describe features: Name: MEDIA ROOM SKYLIGHT Orientation: South ENERGY CODE INSPECTION CHECKLIST JGH007 Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ Doors: [ ] 1. Door: Steel-urth w/brk (30 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ [ ] 2. Door: Steel-urth w/brk (24 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ Floors: [ ] 1. Floor: GR-1 R-30 (17 s.f.), Between conditioned space and ambient conditions R-0.0 continuous insulation, R-30.0 cavity insulation. Name: OVER GARAGE Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Floor: GR-1 R-30 (55 s.f.), Between conditioned space and ambient conditions R-0.0 continuous insulation, R-30.0 cavity insulation. Name: OVER AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Slab Floors: [ ] 1. Slab: R-10, 1'down, 3' in (2243 s.f.) R-10.0 perimeter insulation, R-10.0 under slab insulation. Name: SLAB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Rim and Band Joists: [ ] 1. Joist: COND/AMB (91 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Joist: COND/ATTIC (33 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-15.0 cavity insulation. ENERGY CODE INSPECTION CHECKLIST JGH007 Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Mechanical Equipment: [ ] 1. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 2. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 3. Water Heating: Instant water heater, Natural gas, 0.98 EF, 0.0 Gal. Make and Model Number:_____________________________________________________ Air Leakage Control: [ ] Blower Door Test at Final __________________________ [ ] House is air-sealed so as to achieve 5.00 ACH50 or less at final blower door test. (Max CFM50 is: 3300) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. INFILTRATION REQUIREMENTS FOR IECC. 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation: [ ] Duct System 1 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at 198.000 CFM @ 25 Pascals [ ] Duct System 1 Total Duct Leakage is specified in REM/Rate at 264.000 CFM @ 25 Pascals DUCT LEAKAGE CODE REQUIREMENTS FOR IECC 2009 IECC Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. ENERGY CODE INSPECTION CHECKLIST JGH007 Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. NOTES 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: August 11, 2017 Rating No.: Building Name: JGH007 Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Phone No.: 317-846-4655 Property: 478 SIMON DR Rater's Name: MICHAEL HILL Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 9479271 Builder's Name: HOMES BY McKENZIE, INC Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: JGH007_MCKENZIE_CODE.blg Rating Date: 08-10-2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2009 IECC As Designed Heating: 1171 1161 Cooling: 297 288 Water Heating: 161 161 SubTotal - Used to Determine Compliance: 1629 1610 Lights & Appliances: 971 973 Photovoltaics: -0 -0 Service Charge: 248 248 Total: 2848 2831 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.291 Skylight U-Factor Check (Section 402.5) Skylight U-Factor (Design must be equal or lower): 0.750 0.310 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 1.2%. Name: MICHAEL HILL Signature: Organization: TSI ENERGY SOLUTIONS Date: August 11, 2017 2009 IECC ANNUAL ENERGY COST COMPLIANCE JGH007 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 58.0 kBtuh, 92.1 AFUE. Cooling: Air conditioner, 48.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window-to-Floor Area Ratio: 0.17 Blower door test: Htg: 0.30 Clg: 0.30 ACHnat In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 478 SIMON DR, CARMEL (AS DESIGNED), IN by HOMES BY McKENZIE, INC exceeds the minimum requirements for the 2009 International Energy Conservation Code Building Features Ceiling Flat: R-50.0 Duct Leakage to Outside: 198.00 CFM @ 25 Pascals Sealed Attic: NA Total Duct Leakage: 264.00 CFM @ 25 Pascals Vaulted Ceiling: NA Infiltration: Htg: 5.00 Clg: 5.00 ACH50 Above Grade Walls: R-15.5 Window: U-Value: 0.290, SHGC: 0.270 Foundation Walls: NA Heating Fuel-fired air distribution, Natural gas, 92.1 AFUE. Exposed Floor: R-30.0 Cooling Air conditioner, Electric, 13.0 SEER. Slab: R-10.0 Edge, R-10.0 Under Water Heating Instant water heater, Natural gas, 0.98 EF, 0.0 Gal. Duct: NA 08-10-2017 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name: MICHAEL HILL Signature: Organization: TSI ENERGY SOLUTIONS Date: August 11, 2017 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.3