DOCUMENT APPROVAL
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
___________________________________ _____________________________________________ _____________________________________________ ___________
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT.
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
T111 COVER SHEET AND GENERAL PROJECT NOTES
L100 LIFE SAFETY PLAN
A111 DEMOLITION / ARCHITECTURAL & ELECTRICAL PLAN / REFLECTED
CEILING PLAN: HVAC / LIGHTING / FINISH PLAN
INDEX OF DRAWINGS
COVER SHEET AND
GENERAL NOTES
T111
DATE DESCRIPTION
ISSUE
07.13.17 CONSTRUCTION ISSUE
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
BALDWIN
& LYONS
111 CONGRESSIONAL BLVD - 2ND FLOOR
CARMEL, IN 46032
MKB SLF
2017.253
2ND FLOOR
VICINITY MAP
NOT TO SCALE
NOT TO SCALE
KEY PLAN - 2ND FLOOR
GENERAL PROJECT NOTES
1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
x
OFFICE
204
11'-0" 10'-2"
x
OFFICE
202
11'-10" 10'-3"
x
OFFICE
205
12'-1" 10'-6"
x
OFFICE
203
11'-0" 10'-3"
6x6 6x6
6x6 6x6
6x6
REFRIG
BY
TENANT
8x9'6
DOWN
VEND.
REFRIG
BY
TENANT
FE
ENTRY
201
FE
NLEL
OPEN AREA
206
FE
x
OFFICE
204
11'-0" 10'-2"
x
OFFICE
202
11'-10" 10'-3"
x
OFFICE
205
12'-1" 10'-6"
x
OFFICE
203
11'-0" 10'-3"
ENTRY
201
FE
NLEL
OPEN AREA
206
FE
LIFE SAFETY
WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
3'-4" 4'-5"
SN
SN
SN
S
N
SN
NLEL
OFFICE
204
OFFICE
202
OFFICE
205
OFFICE
203
ENTRY
201
EQ. EQ. EQ.
8'-0"
HOLD
12'-51
2"
FE
OPEN AREA
206
FE
OFFICE
204
OFFICE
202
OFFICE
205
OFFICE
203
ENTRY
201
OPEN AREA
206
8'-0"
D1
3'-0"
F1
8'-2"
3'-0"
3'-4"
2" 2"
8'-0" 2"
ELEC, RCP &
FINISH PLANS
A111
NOT TO SCALE
WALL AT MULLION DETAIL
ARCH. & ELEC. PLAN
WALL - MUST MATCH
WALL CONSTRUCTION
AND INSULATION TYPE AS
ADJOINING WALL.
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
W1 WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
A111
1
DATE DESCRIPTION
ISSUE
07.13.17 CONSTRUCTION ISSUE
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
BALDWIN
& LYONS
111 CONGRESSIONAL BLVD - 2ND FLOOR
CARMEL, IN 46032
MKB SLF
2017.253
2ND FLOOR
N
0 2' 4' 8' 16'
DEMOLITION PLAN
REMOVE WALL MOUNTED STORAGE BOXES.
REMOVE EXISTING 4' DOOR AND FRAME AS SHOWN.
DEMOLITION PLAN NOTES
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
DEMOLITION LEGEND
AREA NOT IN CONTRACT
AREA OF WORK
DEMO, ARCH,
ARCH. & ELEC. NOTES
0 2' 4' 8' 16'
AREA NOT IN CONTRACT
AREA OF WORK
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET, DUPLEX
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
ELECTRICAL LEGEND
GENERAL ELEC. NOTES
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE.
3. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
0 2' 4' 8' 16'
ALIGN FINISHED WALL SURFACES. PROVIDE SAME
THICKNESS STUDS AS EXISTING WALL AT DOOR
INFILLS OR WHERE NEW WALLS ARE IN LINE WITH
EXISTING WALLS.
CONTRACTOR TO PROVIDE NEW FIRE
EXTINGUISHER. ALL FIRE EXTINGUISHERS MUST BE
INSTALLED ACCORDING TO NFPA 10.
PROVIDE POWER AS REQUIRED FOR ELECTRIC
STRIKE AT DOOR FOR CARD READER (CARD
READER BY TENANT). COORDINATE WITH
TENANT'S SECURITY CONTRACTOR. SEE DOOR
SCHEDULE FOR MORE DETAILS.
EXIT LIGHT FIXTURE
EXISTING/RELOCATED
DIFFUSER, LAY-IN, 4"x4'
EXISTING/RELOCATED
DIFFUSER, LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
INDICATES NIGHT LIGHT
LOCATION WITH
EMERGENCY LIGHT
CONNECTION
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND
CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
NEW OR RELOCATED EXISTING TO REMAIN
INDICATES NIGHT LIGHT
LOCATION
EXIT LIGHT FIXTURE
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER, LAY-IN, 4"x4'
DIFFUSER, LAY-IN, 2'x2'
LIGHT FIXTURE, 2'x4'
CEILING LEGEND GENERAL RCP NOTES PLAN NOTES
MECHANICAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE
CODES.
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT 8'-9" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN
TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED
OR MISSING TILES WITH NEW TO MATCH EXISTING. ALL NEW GRID
AND TILES MUST MATCH EXISTING TILE THROUGHOUT SPACE.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1
STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO
MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
5. ALL AIR RETURNS IN PRIVATE OFFICES MUST HAVE A SOUND BOOT
INSTALLED SUCH THAT NO SOUND TRANSFER FROM EACH OFFICE IS
EVIDENT.
LIGHT SWITCH LIGHT SWITCH
REFLECTED CEILING PLAN
0 2' 4' 8' 16'
MFG: ARMSTRONG
TYPE: ULTIMA
COLOR: WHITE
GRID: 15
16" WHITE
REVEAL EDGE
LIGHT FIXTURE, 2'x4', LED
CREE - CR24; REUSE
SALVAGED IN OWNER'S
STOCK
ALL ENTRY AND OPEN AREA LIGHTING TO BE TIED INTO NEW
CORRIDOR SWITCH AND BE CONNECTED TO "SENSOR SWITCH"
MOTION SENSORS WITH PASSIVE INFRARED AND MICROPHONICS
DUAL TECHNOLOGY. EXACT LOCATION AND SPECIFICATION OF
SENSORS TO BE COORDINATED WITH PROPERTY MANAGEMENT
AND MAY INCLUDE CEILING MOUNTED SENSORS.
AREA NOT IN CONTRACT
AREA OF WORK
PLAN NOTES
FLOOR COVERINGS
PAINT / WALLCOVERING
LEGEND
CARPET
PROVIDE KOROSEAL KOROGARD EXTRUDED CORNER GUARD, STYLE #: G875, 3
4" WINGS, FROM TOP OF VINYL BASE TO
BOTTOM OF CEILING. GUARD ANGLE MUST BE 90 DEGREES OR 135 DEGREES AS SHOWN ON PLAN. COLOR TO MATCH
SCHEDULED PAINT AS FOLLOWS:
PT1 - VAPOR
AREA NOT IN CONTRACT FINISH PLAN
AREA OF WORK
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC
INTERIOR LATEX
COLOR: SW 7637 OYSTER WHITE
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC
INTERIOR LATEX
COLOR: SW 6136 HARMONIC TAN
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC
INTERIOR LATEX
COLOR: SW 6348 REYNARD
FINISH: EGGSHELL
MFG: JOHNSONITE
TYPE: 4" VINYL COVE, 1
8" GAUGE
COLOR: 27 MIST
MFG: JOHNSONITE
TYPE: 4" VINYL COVE, 1
8" GAUGE
COLOR: 461 WICKER
MFG: JOHNSONITE
TYPE: 4" VINYL COVE, 1
8" GAUGE
COLOR: 165 SQUASHED
MFG: SHAW CONTRACT GROUP
TYPE: MODULAR
PATTERN: 5T018 TANGLE
COLOR: 18740 INTERLACE
NOTE: INSTALL QUARTER-TURN
1. EXISTING CEILING GRID AND TILE TO REMAIN. REMOVE ALL
EXISTING LIGHT FIXTURES THROUGHOUT. SEE REFLECTED
CEILING PLAN FOR NEW LIGHTING INFORMATION.
2. REMOVE ANY ELECTRICAL OUTLETS OR DATA ABOVE THE
STANDARD 18" A.F.F. ALL THOSE AT THE STANDARD 18" CAN
REMAIN AND BE REUSED WHERE POSSIBLE.
GENERAL DEMO NOTES
TYP.
A111
1
DOOR SCHEDULE
NUM. DIMENSIONS DOORS FRAME
TYPE MATERIAL FINISH
HARDWARE
TYPE MATERIAL FINISH SET
3'-0"x8'-0"x13
4" D1 F1 PS, CH
3'-0"x8'-0"x13
4" D1 F1
SOLID CORE
PLAIN SLICED. BOMBAY FRAMEWORKS
CLEAR
ANODIZED
SOLID CORE
PLAIN SLICED. BOMBAY FRAMEWORKS
CLEAR
ANODIZED SL, ES, CL, CR
3'-0"x8'-0"x13
4" D1 F1 PS, CH
SOLID CORE
PLAIN SLICED. BOMBAY FRAMEWORKS
CLEAR
ANODIZED
3'-0"x8'-0"x13
4" D1 F1 PS, CH
SOLID CORE
PLAIN SLICED. BOMBAY FRAMEWORKS
CLEAR
ANODIZED
3'-0"x8'-0"x13
4" D1 F1 PS, CH
SOLID CORE
PLAIN SLICED. BOMBAY FRAMEWORKS
CLEAR
ANODIZED
1. REUSE SALVAGED DOORS FROM BUILDING STORAGE
THAT MATCH BALDWIN STANDARDS. TOUCH UP AS
NEEDED FOR AS-NEW APPEARANCE. STAIN NEW
DOORS TO MATCH EXISTING. PRE-MACHINE NEW
DOORS FOR CYLINDRICAL LOCKSETS.
2. PROVIDE NEW HARDWARE TO MATCH BALDWIN
STANDARD ON NEW DOORS. REUSE EXISTING
HARDWARE ON SALVAGED DOORS WHERE
POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE
BUILDING STANDARD, GRADE 2 MINIMUM. PROVIDE
A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK
AND LATCHSETS.
3. PROVIDE NEW BALDWIN STANDARD FRAMES AS
REQUIRED. REUSE SALVAGED WHERE POSSIBLE.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM
ADJACENT WALL CORNERS UNLESS OTHERWISE
NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING
REQUIREMENTS AND LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE
SPECIFICATION, PURCHASE, AND INSTALLATION OF
ALL ACCESS CONTROLLED ELECTRONIC AND/OR
MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST
COMPLY WITH THE INDIANA BUILDING CODE,
CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR
FRAMES UNLESS OTHERWISE NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE
APPLICABLE) AT EACH DOOR UNLESS OTHERWISE
NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
CL CLOSER
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
PS PASSAGE LATCHSET
SL STOREROOM LOCKSET
HARDWARE LEGEND
LIFE SAFETY PLAN L100
DATE DESCRIPTION
ISSUE
07.13.17 CONSTRUCTION ISSUE
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
BALDWIN
& LYONS
111 CONGRESSIONAL BLVD - 2ND FLOOR
CARMEL, IN 46032
MKB SLF
2017.253
2ND FLOOR
N
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
LIFE SAFETY NOTES
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
GENERAL NOTES
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
FE FE
AREA NOT IN CONTRACT
AREA OF WORK
TRAVEL DISTANCE
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
NUMBER OF EXITS REQUIRED: 1 PROVIDED: 1
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
38,897 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 8
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978? NO
775
775
8
BUILDING CONSTRUCTION TYPE I-B
TRAVEL DISTANCE = 48'
38,897 5 194,485
0 4' 8' 16'
ENLARGED LIFE SAFETY PLAN
0 2' 4' 8' 16'
EX
EX
BUSINESS
BUSINESS
BUSINESS
BUSINESS
BUSINESS
BUSINESS
ATRIUM
OPEN TO BELOW
EP
NIGHT LIGHT/EMERGENCY LIGHTING
NLEL
EP
BASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE
DESIGN-BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY
FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR
PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL
INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL,
ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL
APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM
SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND
MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR
COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS.
2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST
COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE
ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE
OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE
OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD.
4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE
PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS
REQUIRED BY CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR
OTHER CONFLICTS.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER
AND DATA OUTLETS AS REQUIRED.
9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO
BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND
PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCH
EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
PURCHASE.
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.
REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE
TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM
WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE
FOR WIRING THE BASE PANELS OF THE WORKSTATIONS.
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL
CONDUITS TO JUNCTION BOXES.
14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN
EXISTING SPACES. CONSULT WITH LANDLORD.
15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.
16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.
REQUIREMENTS.
17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVER PLATE.
18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.
19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS
OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION.
FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR
EXPENSE.
21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS
(I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS).
MECHANICAL &
ELECTRICAL NOTES
1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA
BUILDING CODE FOR CLASS A FIRE RATINGS.
2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM
ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS,
CORNER BEADS, ETC.)
3. ALL NEW PLATES AND SWITCHES ARE TO MATCH EXISTING COLOR, UNLESS OTHERWISE
NOTED. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS.
CONTRACTOR TO CONFIRM EXISTING COLOR PRIOR TO PURCHASING NEW.
4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH
COATS.
5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET).
6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE
NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK.
PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING
OWNER.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.
8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO
MATCH ADJACENT WALL FINISH.
9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT
DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL
MILLWORK.
10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH
INFORMATION.
11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
FINISH NOTES
1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
PROVIDED UNDER THE GENERAL CONTRACT.
2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
(A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING
SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION
DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
CONTRACTOR.
6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.
BACKSPLASHES TO BE FIELD APPLIED.
7. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS
(CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY).
8. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
MILL/CASEWORK NOTES
1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO
DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS.
2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR
OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT
MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE
CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR
AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING
THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE
ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF
WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS.
4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE
BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN
THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING
AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY
OWNER.
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN.
VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION.
6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES TO REMAIN.
7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.
SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.
8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID
INSTRUCTIONS.
9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO
REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION
EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE
CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY
SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE
BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE
OWNER'S USE IN THE PROJECT.
10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION)
REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING
BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES,
AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES.
REFER TO SECTION 300.21.
11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL
TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN
"AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS.
12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
DEMOLITION NOTES
1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE .
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND
LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE
CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.
3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS
OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR
WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS
OF THE SCOPE OF WORK.
4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS
PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS.
NOTED DIMENSIONS TAKE PRECEDENCE.
5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY
DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC.
6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL
ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS
STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,
AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE
CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN
ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.
7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING
HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING
HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND
WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS
OF ADJACENT TENANTS.
8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL
COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE
OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER
FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR
DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE
CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.
9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH
APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY
SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.
10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND
SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,
SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR
MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.
11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO
CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR
STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING
CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES
SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED
BY CONSTRUCTION CREWS.
13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF
DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST
PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6
MIL VAPOR BARRIER ON EACH SIDE.
14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED
BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF
THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING
MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS
INDICATED ON THE CEILING PLAN).
15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY,
PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT
OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE.
16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS
INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR
APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO
DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT
INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.
18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT
TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF
MATERIALS AND EQUIPMENT.
19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY
STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH
ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL,
MECHANICAL, AND ELECTRICAL CONSTRUCTION.
20. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY
SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.
21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER
TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY
CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER
DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING
MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT
ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED
AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED.
23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING
WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION
JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS.
24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH
DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE
FOR FINISH.
25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.
26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE
CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT
REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL
CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK.
27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR
INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT.
28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM
BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE
DRAWINGS. WRITTEN DIMENSIONS GOVERN.
29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS.
REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING
STANDARD.
30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS
REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND
SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT
DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL
CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR
AGREEMENT.
31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH
APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED
PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE
DAMPERED IF REQUIRED.
33. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND
WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW
CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED.
1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN,
INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE
SPRINKLER SYSTEM.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE,
THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND
REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE
SUPPRESSION SYSTEMS.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND
SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
FIRE PROTECTION NOTES