HomeMy WebLinkAbout1800W106TH_TIMOTHY_AS-DESIGNEDBUILDING FILE REPORT File Name: 1800W106TH_TIMOTHY_CODE.blg Date: October 06, 2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Property/Builder: Organization Building Name: Org. Name: TSI ENERGY SOLUTIONS Owner's Name: TIMOTHY HOMES Address: P.O. BOX 705 Property Address: 1800 W 106TH ST City, St, Zip: CARMEL, IN 46082 City, St, Zip: CARMEL (AS DESIGNED), IN 46032 Phone No: 317-846-4655 Phone No: Website: www.tsienergysolutions.com Builder's Name: TIMOTHY HOMES Rater's Name: MICHAEL HILL Phone No: Rater's Email: mhill@tsienergysolutions.com Email Address: Rater's ID: 9479271 Model: CUSTOM Provider ID: 1998-053 Development: 1800 W 106TH ST Sample Set ID: 0000 Permit Date/Number: Rating Date: 10/06/2017 Rating Type: Projected Rating Reason: New Home Rating No.: Registry ID: Verifier's Name: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name: Verifier's ID: BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. General Building Information Area of Cond. Space(sq ft): 9807 Volume of Cond. Space: 104218 Year Built: 2017 Housing Type: Single-family detached Level Type(Apartments Only): None Floors on or Above-Grade: 2 Number of Bedrooms: 5 Foundation Type: Conditioned basement Enclosed Crawl Space Type: N/A Number of Stories Including Conditioned Basement: 3 Thermal Boundary Location: N/A Foundation Wall Info: 1 2 3 Name COND/AMB COND/AMB UNFIN COND/GARAGE UNFIN Library Type R-19 2X6 FINISHED Uninsulated Uninsulated Length(ft) 126.0 146.0 26.0 Total Height(ft) 10.0 10.0 10.0 Depth Below Grade(ft) 9.0 9.0 9.0 Height Above Grade(ft) 1.0 1.0 1.0 Location Cond->ambient/grnd Cond->ambient/grnd Cond->garage/grnd Uo Value (wall, airfilm, & soil) 0.041 0.171 0.171 Uo Value (wall assembly only) 0.062 1.205 1.205 Foundation Wall: R-19 2X6 FINISHED Type: Solid concrete or stone Thickness(in): 8.0 Studs: Wood, 2x6, 16" o.c. Interior Insulation: Continuous R-Value: 0.5 Frame Cavity R-Value: 19.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 0.0 ft from bottom of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft from top of wall Ins bottom: 0.0 ft below grade Note: BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Foundation Wall: Uninsulated Type: Solid concrete or stone Thickness(in): 10.0 Studs: None Interior Insulation: Continuous R-Value: 0.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 0.0 ft from bottom of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft from top of wall Ins bottom: 0.0 ft below grade Note: Slab Floor Info: 1 Name BSMT Library Type Uninsulated Area(sq ft) 4011 Depth Below Grade(ft) 9.0 Full Perimeter(ft) 298 Exposed Perimeter(ft) 298 On-Grade Perimeter(ft) 0 Slab Floor: Uninsulated Slab Covering None Perimeter Insulation (R-Value): 0.0 Perimeter Insulation Depth (ft): 0.0 Under-Slab Insulation (R-Value): 0.0 Under-Slab Insulation Width (ft): 0.0 Slab Insulation Grade: 1 Radiant Slab: No Note: BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Rim and Band Joist: 1 2 3 Name COND/AMB COND/GARAGE COND/ATTIC Area(sq ft) 367.0 26.0 79.0 Continuous Ins 0.5 0.5 0.5 Framed Cavity Ins 19.0 19.0 19.0 Cavity Ins Thk(in) 5.5 5.5 5.5 Joist Spacing 16.0 16.0 16.0 Insulation Grade 1 1 1 Location Cond -> ambient Cond -> garage Cond -> attic Uo Value 0.049 0.049 0.049 Above-Grade Wall: 1 2 3 Name COND/AMB COND/AMB 2X6 COND/GAR Library Type G1 R-16 BATT, OSB G1 R-19, OSB 2x6 G1 R-16 Gar Walls Gross Area(sq ft) 3077.00 902.00 260.00 Exterior Color Medium Medium Medium Location Cond -> ambient Cond -> ambient Cond -> garage Uo Value 0.073 0.058 0.074 Above-Grade Wall: 4 Name COND/ATTIC Library Type G1 R-16 BATT, OSB Gross Area(sq ft) 775.00 Exterior Color Medium Location Cond -> attic Uo Value 0.073 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-16 BATT, OSB Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 16.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 16.000 4.375 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 18.740 7.115 3.770 U-Value 0.053 0.141 0.265 Relative Area 0.770 0.230 0.000 UA 0.041 0.032 0.000 Total Component UA: 0.073 Total Component Area: 1.0 Component Uo: 0.073 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-19, OSB 2x6 Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 19.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1988 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 19.000 6.875 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 21.740 9.615 3.770 U-Value 0.046 0.104 0.265 Relative Area 0.801 0.199 0.000 UA 0.037 0.021 0.000 Total Component UA: 0.058 Total Component Area: 1.0 Component Uo: 0.058 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-16 Gar Walls Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 16.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 1.0 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.900 0.900 0.900 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 16.000 4.375 1.030 Continuous ins 0.000 0.000 0.000 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 18.690 7.065 3.720 U-Value 0.054 0.142 0.269 Relative Area 0.770 0.230 0.000 UA 0.041 0.033 0.000 Total Component UA: 0.074 Total Component Area: 1.0 Component Uo: 0.074 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 8 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 1 2 3 Name FRONT FRONT 2X6 FRONT RIGHT Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 190.00 40.00 20.00 Orientation South South Southeast Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 2 AGWall 1 Window Information: 4 5 6 Name FRONT LEFT BACK SLIDER Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 20.00 36.00 48.00 Orientation Southwest North North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 9 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 7 8 9 Name GD LEFT SIDE GD Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 24.00 216.00 24.00 Orientation North West West Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Window Information: 10 11 12 Name RIGHT 2X6 RIGHT SIDE GD 2X6 RIGHT SIDE GD 2X6 Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 132.00 48.00 48.00 Orientation East East East Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 2 AGWall 2 AGWall 2 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 10 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 13 Name BSMT RIGHT Library Type U-.31, SHGC-.30 U-Value 0.310 SHGC 0.300 Area(sq ft) 18.00 Orientation East Overhang Depth 0.0 Overhang To Top 0.0 Overhang To Bottom 0.0 Interior Winter Shading 0.85 Interior Summer Shading 0.70 Adjacent Winter Shading None Adjacent Summer Shading None Wall Assignment FndWall 1 Window: U-.31, SHGC-.30 U-Value: 0.310 Solar Heat Gain Coefficient: 0.300 Note: Door Information: 1 2 Name FRONT GARAGE Opaque Area(sq ft) 48.0 18.0 Library Type Steel-polystyrene Steel-polystyrene Wall Assignment AGWall 2 AGWall 3 Uo Value 0.341 0.341 Door: Steel-polystyrene R-Value of Opaque Area: 2.0 Storm Door: No Note: Roof Information: 1 Name SECOND Library Type R-38 Blown, Attic, 1 Ceiling Area(sq ft) 4011.00 Roof Area(sq ft) 4011.00 Color Medium Radiant Barrier No Type(Attic) Attic Uo Value 0.026 Clay or Cement Tiles: No Sub Roof Ventilation: No BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 11 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Ceiling: R-38 Blown, Attic, 1 Information From Quick Fill Screen: Continous Insulation (R-Value) 25.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Attic Note: Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.450 0.450 0.450 Cavity Ins/Frm 4.375 13.000 0.000 Continuous ins 25.000 25.000 25.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.610 0.610 0.610 Total R-Value 31.045 39.670 26.670 U-Value 0.032 0.025 0.037 Relative Area 0.110 0.890 0.000 UA 0.004 0.022 0.000 Total Component UA: 0.026 Total Component Area: 1.0 Component Uo: 0.026 Mechanical Equipment: General Number of Mechanical Systems: 5 Heating SetPoint(F): 68.00 Heating Setback Thermostat: Present Cooling SetPoint(F): 78.00 Cooling Setup Thermostat: Present BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 12 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Heat: 912SA60100S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 97.1 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 930 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 50 Number Of Units: 1 Heat: 912SA60100S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 97.1 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 930 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 50 Number Of Units: 1 Cooling Equipment: CA13NA048 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 45.5 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 50 Number Of Units: 1 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 13 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Cooling Equipment: CA13NA048 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 45.5 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 50 Number Of Units: 1 Water Heating Equipment: GPVX 75L 200 Water Heater Type: Conventional Fuel Type: Natural gas Energy Factor: 0.68 Recovery Efficiency: 0.84 Water Tank Size (gallons): 75 Extra Tank Insulation (R-Value): 0.0 Note: Location: Conditioned area Percent Load Served: 100 Performance Adjustment: 100 Number Of Units: 1 DHW Efficiencies All bath faucets & showers <= 2gpm: false All DHW pipes fully insulated >= R-3: false Recirculation type: None (standard system) Farthest fixture to DHW heater 80 TOTAL Pipelength for longest DHW run: 110 DWHR unit present?: false BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 14 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct System Information: Name SYSTEM 1 Heating System 912SA60100S17A Cooling System CA13NA048 Supply Area(sq ft) 527.6 Return Area(sq ft) 293.1 Conditioned Floor Area(sq ft) 5211.0 # of Registers 3 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 208.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 416.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 1 2 Type Supply Return Percent Area 100.0 100.0 R-Value 6.0 6.0 Location Conditioned space Conditioned space Duct System Information: Name SYSTEM 2 Heating System 912SA60100S17A Cooling System CA13NA048 Supply Area(sq ft) 465.3 Return Area(sq ft) 258.5 Conditioned Floor Area(sq ft) 4596.0 # of Registers 3 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 180.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 360.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 1 2 3 Type Supply Return Supply Percent Area 95.0 95.0 5.0 R-Value 30.0 30.0 6.0 Location Attic, under insulation Attic, under insulation Conditioned space BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 15 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct Information: 4 Type Return Percent Area 5.0 R-Value 6.0 Location Conditioned space Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type: Blower door test Heating Season Infiltration Value: 4.00 ACH @ 50 Pascals Cooling Season Infiltration Value: 4.00 ACH @ 50 Pascals Shelter Class 4 Code Verification: Tested Mechanical Ventilation for IAQ Type: None Rate(cfm): 0 Sensible Recovery Efficiency(%): 0.00 Total Recovery Efficiency(%): 0.00 Hours per Day: 24.00 Fan Power (watts): 0.00 ECM Fan Motor: false Ventilation Strategy for Cooling Cooling Season Ventilation: Natural Ventilation Lights and Appliances Simplified Audit Refrigerator KWh: 709 Refrigerator Location: Conditioned Dishwasher EF: 0.46 Dishwasher kWh/yr: 0 Dishwasher Capacity: 12 Dishwasher kWh/Year: 0 Range/Oven Fuel Type: Natural gas Induction Range: No Convection Oven: No Clothes Dryer Fuel Type: Electric Clothes Dryer Location: Conditioned Clothes Dryer Moisture Sensing: No Clothes Dryer Energy Factor: 3.01 Clothes Dryer Gas Energy Factor: 2.67 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 16 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Lights and Appliances Clothes Washer Location: Conditioned Clothes Washer LER: 704.0 Clothes Washer MEF: 0.817 Clothes Washer Capacity: 2.874 Clothes Washer Electricity Rate: 0.08 Clothes Washer Gas Rate: 0.58 Clothes Washer Annual Gas Cost: 23.00 Percent CFLs: 0.0 Percent Fluorescent: 10.0 Percent Exterior Lights: 0.0 Percent Garage Lights: 0.0 Ceiling Fan CFM / Watt: 0.00 BUILDING FILE REPORT 1800W106TH_TIMOTHY_CODE.blg Page 17 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Mandatory Requirements IECC Requirements Verified IECC 04: true Verified IECC 06: true Verified IECC 09: true Verified IECC 12: false Verified IECC 15: false Verified NY-ECCC 2010: false Verified Michigan: false Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist (National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Refrigerators: 0 Ceiling Fans: 0 Exhaust Fans: 0 Dishwashers: 0 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grade: false Basement Floor Area: 0 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist: false EPA Field App ID ENERGY CODE INSPECTION CHECKLIST Date: October 06, 2017 Rating No.: Building Name: Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: TIMOTHY HOMES Phone No.: 317-846-4655 Property: 1800 W 106TH ST Rater's Name: MICHAEL HILL Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 9479271 Builder's Name: TIMOTHY HOMES Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: 1800W106TH_TIMOTHY_CODE.blg Rating Date: 10/06/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Building Information: Conditioned Area (sq ft): 9807 Conditioned Volume (cubic ft): 104218 Insulated Shell Area (sq ft): 16488 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TSI ENERGY SOLUTIONS's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings: [ ] 1. Attic: R-38 Blown, Attic, 1 (4011 s.f.) R-25.0 continuous insulation, R-13.0 cavity insulation. Name: SECOND Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Above-Grade Walls: [ ] 1. Wall: G1 R-16 BATT, OSB (3077 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-16.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: G1 R-19, OSB 2x6 (902 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/AMB 2X6 Insulation Grade: I II III Face / Inset ENERGY CODE INSPECTION CHECKLIST 1800W106TH_TIMOTHY_CODE.blg Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ [ ] 3. Wall: G1 R-16 Gar Walls (260 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-16.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 4. Wall: G1 R-16 BATT, OSB (775 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-16.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Windows and Skylights: Window-to-Wall Area Ratio: 0.17 [ ] 1. Window: U-.31, SHGC-.30 (190 s.f., South), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: FRONT Orientation: South Comments/Location___________________________________________________________ [ ] 2. Window: U-.31, SHGC-.30 (40 s.f., South), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: FRONT 2X6 Orientation: South Comments/Location___________________________________________________________ [ ] 3. Window: U-.31, SHGC-.30 (20 s.f., Southeast), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: FRONT RIGHT Orientation: Southeast Comments/Location___________________________________________________________ [ ] 4. Window: U-.31, SHGC-.30 (20 s.f., Southwest), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: FRONT LEFT Orientation: Southwest Comments/Location___________________________________________________________ [ ] 5. Window: U-.31, SHGC-.30 (36 s.f., North), U-Value: 0.310, SHGC: 0.300 ENERGY CODE INSPECTION CHECKLIST 1800W106TH_TIMOTHY_CODE.blg Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. For windows without labeled U-factors, describe features: Name: BACK Orientation: North Comments/Location___________________________________________________________ [ ] 6. Window: U-.31, SHGC-.30 (48 s.f., North), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: SLIDER Orientation: North Comments/Location___________________________________________________________ [ ] 7. Window: U-.31, SHGC-.30 (24 s.f., North), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: GD Orientation: North Comments/Location___________________________________________________________ [ ] 8. Window: U-.31, SHGC-.30 (216 s.f., West), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: LEFT SIDE Orientation: West Comments/Location___________________________________________________________ [ ] 9. Window: U-.31, SHGC-.30 (24 s.f., West), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: GD Orientation: West Comments/Location___________________________________________________________ [ ] 10. Window: U-.31, SHGC-.30 (132 s.f., East), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: RIGHT 2X6 Orientation: East Comments/Location___________________________________________________________ [ ] 11. Window: U-.31, SHGC-.30 (48 s.f., East), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: RIGHT SIDE GD 2X6 Orientation: East Comments/Location___________________________________________________________ ENERGY CODE INSPECTION CHECKLIST 1800W106TH_TIMOTHY_CODE.blg Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. [ ] 12. Window: U-.31, SHGC-.30 (48 s.f., East), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: RIGHT SIDE GD 2X6 Orientation: East Comments/Location___________________________________________________________ [ ] 13. Window: U-.31, SHGC-.30 (18 s.f., East), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: BSMT RIGHT Orientation: East Comments/Location___________________________________________________________ Doors: [ ] 1. Door: Steel-polystyrene (48 s.f.), R-Value 2.0 Comments/Location___________________________________________________________ [ ] 2. Door: Steel-polystyrene (18 s.f.), R-Value 2.0 Comments/Location___________________________________________________________ Foundation Walls: [ ] 1. Wall: R-19 2X6 FINISHED (1260 s.f.), Between conditioned space and ambient/ground R-0.5 interior continuous insulation, R-19.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: Uninsulated (1460 s.f.), Between conditioned space and ambient/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/AMB UNFIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Wall: Uninsulated (260 s.f.), Between conditioned space and garage/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/GARAGE UNFIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Slab Floors: ENERGY CODE INSPECTION CHECKLIST 1800W106TH_TIMOTHY_CODE.blg Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. [ ] 1. Slab: Uninsulated (4011 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: BSMT Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Rim and Band Joists: [ ] 1. Joist: COND/AMB (367 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Joist: COND/GARAGE (26 s.f.), Between conditioned space and garage R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/GARAGE Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Joist: COND/ATTIC (79 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Mechanical Equipment: [ ] 1. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 2. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 3. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 4. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ ENERGY CODE INSPECTION CHECKLIST 1800W106TH_TIMOTHY_CODE.blg Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. [ ] 5. Water Heating: Conventional, Natural gas, 0.68 EF, 75.0 Gal. Make and Model Number:_____________________________________________________ Air Leakage Control: [ ] Blower Door Test at Final __________________________ [ ] House is air-sealed so as to achieve 4.00 ACH50 or less at final blower door test. (Max CFM50 is: 6948) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. INFILTRATION REQUIREMENTS FOR IECC. 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation: [ ] Duct System 1 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at 208.000 CFM @ 25 Pascals [ ] Duct System 1 Total Duct Leakage is specified in REM/Rate at 416.000 CFM @ 25 Pascals [ ] Duct System 2 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 2 Leakage to Outside is specified in REM/Rate at 180.000 CFM @ 25 Pascals [ ] Duct System 2 Total Duct Leakage is specified in REM/Rate at 360.000 CFM @ 25 Pascals DUCT LEAKAGE CODE REQUIREMENTS FOR IECC 2009 IECC Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. ENERGY CODE INSPECTION CHECKLIST 1800W106TH_TIMOTHY_CODE.blg Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. NOTES 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: October 06, 2017 Rating No.: Building Name: Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: TIMOTHY HOMES Phone No.: 317-846-4655 Property: 1800 W 106TH ST Rater's Name: MICHAEL HILL Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 9479271 Builder's Name: TIMOTHY HOMES Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: 1800W106TH_TIMOTHY_CODE.blg Rating Date: 10/06/2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2009 IECC As Designed Heating: 2127 2130 Cooling: 511 455 Water Heating: 184 192 SubTotal - Used to Determine Compliance: 2822 2776 Lights & Appliances: 2029 2035 Photovoltaics: -0 -0 Service Charge: 248 248 Total: 5100 5059 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.310 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 1.6%. Name: MICHAEL HILL Signature: Organization: TSI ENERGY SOLUTIONS Date: October 06, 2017 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 97.1 kBtuh, 92.1 AFUE. Heating: Fuel-fired air distribution, 97.1 kBtuh, 92.1 AFUE. Cooling: Air conditioner, 45.5 kBtuh, 13.0 SEER. Cooling: Air conditioner, 45.5 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.68 EF. 2009 IECC ANNUAL ENERGY COST COMPLIANCE 1800W106TH_TIMOTHY_CODE.blg Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Window-to-Floor Area Ratio: 0.09 Blower door test: Htg: 0.30 Clg: 0.30 ACHnat In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 1800 W 106TH ST, CARMEL (AS DESIGNED), IN by TIMOTHY HOMES exceeds the minimum requirements for the 2009 International Energy Conservation Code Building Features Ceiling Flat: R-38.0 Duct Leakage to Outside: 208.00 CFM @ 25 Pascals Sealed Attic: NA Total Duct Leakage: 416.00 CFM @ 25 Pascals Vaulted Ceiling: NA Infiltration: Htg: 4.00 Clg: 4.00 ACH50 Above Grade Walls: R-16.5 Window: U-Value: 0.310, SHGC: 0.300 Foundation Walls: R-0.0 Heating Fuel-fired air distribution, Natural gas, 92.1 AFUE. Exposed Floor: NA Cooling Air conditioner, Electric, 13.0 SEER. Slab: R-0.0 Edge, R-0.0 Under Water Heating Conventional, Natural gas, 0.68 EF, 75.0 Gal. Duct: NA 10/06/2017 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name: MICHAEL HILL Signature: Organization: TSI ENERGY SOLUTIONS Date: October 06, 2017 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.3