HomeMy WebLinkAboutAllegion Bid Set REV2 11.30.17MICRO REFRIG MICRO VEND. VEND. ICE COVER SHEET AND GENERAL NOTES T111 DATE DESCRIPTION ISSUE 10.11.17 REVIEW SET 10.13.17 PERMIT SET 11.09.17 BID SET REVISIONS MARK DATE DB DESCRIPTION 11.10.17 AM REV1 11.30.17 AM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com ALLEGION ENGINEERING 11805 N. PENNSYLANNIA ST. - 1ST FLOOR CARMEL, IN 46032 MMS/ACM MMS 2017.280 1ST FLOOR DOCUMENT APPROVAL TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. ___________________________________ _____________________________________________ _____________________________________________ ___________ TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT. THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. GENERAL PROJECT NOTES 1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO BASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN-BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL, ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS. 2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 x ELECTRICAL 133 11'-5" 13'-4" 6x5 6x5 6x5 6x5 6x5 6x5 6x5 x CONFERENCE 108 x 12'-8" 18'-11" CONFERENCE 103 24'-6" 14'-10" x CONFERENCE 102 24'-6" 16'-4" WOMEN MEN 107 106 x OFFICE 113 13'-7" 11'-2" x CONFERENCE 132 18'-1" 11'-8" OPEN OFFICE 129 OPEN OFFICE 135 OPEN OFFICE 112 ENTRY 101 COPY WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL FE EL OFFICE 107 OFFICE 109 ENTRY 101 ADVANCED DEVE. AREA 102 TESTING 108 INDUSTRIAL DESIGN MEETING AREA 104 ID LAB 105 FLEX SPACE 106 INDUSTRIAL DESIGN AREA 103 22'-83 4" 4'-5 3 4" (CLEAR) 21'-51 4" CONFERENCE 141 FE 10'-113 4" 8'-21 4" EQ. 8'-0" EQ. P P OFFICE 107 OFFICE 109 ENTRY 101 DISPLAY CASE 6x5 6x5 6x5 6x5 6x5 6x5 LF ADVANCED DEVE. AREA 102 TESTING 108 6x5 6x5 LF LF PLOTTER TV LF INDUSTRIAL DESIGN MEETING AREA 104 ID LAB 105 FLEX SPACE 106 LF LF INDUSTRIAL DESIGN AREA 103 VF VF VF VF 6x5 LF LF 6x5 6x5 6x5 TV TV CONFERENCE 141 J J J +72" +72" DED +72" +72" P +72" +72" +72" EXIST 4"V. EXIST 4"W. 2"W. F.F. 2"W. 2"W. SINK TO BUILDING DRAIN F.F. 11 2"V. CLG. 11 2"V. CLG. TO EXISTING STACK TILE CUT TILE AS SCHEDULED SILICONE TRIM PIECE (TR1) DRYWALL TILE 6" F1 8'-0" 2" 3'-0" 3'-4" 2" 2" 7'-10" 7'-10" D1 3'-0" 3'-8" 8" 8" 7'-10" 3'-0" D3 1 4" TEMPERED GLASS 1'-8" 1/2" TEMPERED GLASS 8'-0" 3'-0" 3'-6" 4" STAINLESS STEEL TOP RAIL 4" STAINLESS STEEL BOTTOM RAIL PROVIDE ONE PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2), AS NOTED IN REMARKS D2 4'-2" 8'-0" 7'-8" 7'-6" SLIDING DOOR HARDWARE AS SCHEDULED, TOP TRACK 8'-0"W x 7'-6"H DRYWALL WRAPPED OPENING 4'-2" D4 5' LONG PULL AS NOTED IN REMARK OFFICE 107 OFFICE 109 ENTRY 101 ADVANCED DEVE. AREA 102 TESTING 108 INDUSTRIAL DESIGN MEETING AREA 104 ID LAB 105 FLEX SPACE 106 INDUSTRIAL DESIGN AREA 103 CONFERENCE 141 8" 8" 8" 7'-10" 3'-0" D5 1 4" TEMPERED GLASS DOOR SCHEDULE INTERIOR DETAILS A211 NOTE: REFER TO FLOORPLAN FOR SINK LOCATIONS. DATE DESCRIPTION ISSUE 10.11.17 REVIEW SET 10.13.17 PERMIT SET 11.09.17 BID SET REVISIONS MARK DATE DB DESCRIPTION 11.10.17 AM REV1 11.30.17 AM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com ALLEGION ENGINEERING 11805 N. PENNSYLANNIA ST. - 1ST FLOOR CARMEL, IN 46032 MMS/ACM MMS 2017.280 1ST FLOOR 2 1 FINISH PLAN NOTES AREA NOT IN CONTRACT AREA OF WORK FINISH PLAN FINISH PLAN/ FLOOR COVERINGS LEGEND PROVIDE SCHLUTER SCHIENE TRANSITION STRIP AT CARPET TO TILE TRANSITION, FINISH: BRUSHED STAINLESS STEEL (EB). PROVIDE LEVELING LATEX UNDER CARPET AS SUCH THAT TOP OF FINISHES ARE LEVEL. SEAM SEAL CARPET EDGES. TRANSITION STRIP MUST BE LEVEL WITH OR SLIGHTLY HIGHER THAN TILE EDGE. TRANSITION PROFILE MUST BE APPROPRIATE FOR FLOORING MATERIALS AND MUST BE SUBMITTED TO SDI FOR FINAL APPROVAL PRIOR TO INSTALLATION. EXISTING WALL FINISH TO REMAIN. INSTALL DRY ERASE WALLCOVERING WC1, FROM 36" TO 84" A.F.F. WALL FINISH ABOVE AND BELOW TO BE PAINTED. PROVIDE 1 1/2" ANODIZED ALUMINUM TRIM AT TOP AND BOTTOM EDGE OF WALLCOVERING. PROVIDE 48" WIDE ANODIZED ALUMINUM MARKER TRAY CENTERED ON BOTTOM TRIM. PROVIDE ALTERNATE PRICE TO INSTALL WC1 FULL HEIGHT. SEAM SEAL ALL CUT CARPET EDGES. TRANSITION TO OCCUR 35'-0" FROM CORNER OUTSIDE OFFICE 113 AS SHOWN ON PLAN. DESIGN INTENT IS FOR AREA WITH TILES TO BEGIN ON NORTH SIDE WITH FULL PLANK AND END ON SOUTH SIDE WITH FULL PLANK. ADJUST SOUTH SIDE TRANSITION AS REQUIRED. EDGE OF CARPET TO ALIGN WITH EDGE OF WALL. PROVIDE VERTICAL ANODIZED ALUMINUM TRIM AT TOP OF EXPOSED EDGE OF WALLCOVERING. TYPICAL ALL SINGLE LOCATIONS,NOT TO SCALE RISER DIAGRAM A211 1 0 2' 4' 8' 16' DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 01 R2 02 DRYWALL WRAPPED OPENING 8R ,3R 03 04 05 06A NEW SEE REMARKS SEE REMARKS R1 06B PS, CL 07 R4 08A CASED OPENING 08B R5 08C R6 08D R7 08E CASED OPENING 09 R4 41 R4 CL CLOSER CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES HARDWARE LEGEND HERCULITE SYSTEM D2 HERCULITE GLASS SYSTEM -- -- -- SEE REMARK D4 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. SEE REMARK 3'-0"x7'-10"x13 4" D5 SOLID CORE BIRCH VNR. DRYWALL WRAPPED OPENING PS REMARKS TYPE MATERIAL FINISH TYPE MATERIAL FINISH DOOR/FRAME TYPES DOOR/FRAME NOTES 1. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. R1. NEW EXTERIOR STOREFRONT DOUBLE DOOR TO BE INTEGRATED INTO EXISTING STOREFRONT. INTENT IS TO MATCH EXISTING MATERIALS/FINISHES. PROVIDE ALL NECESSARY SWEEPS, SEALS, HARDWARE, THRESHOLDS, ETC AS REQUIRED FOR EXTERIOR DOOR. DOOR TO HAVE TENANT PROVIDED CARD READER. DOOR STYLE TO HAVE 6" STYLE, 6" TOP RAIL, 10" MIN. BOTTOM RAIL, FULL GLASS. CONTACT KEVIN MORGAN FOR REQUIREMENTS (317)715-4506. ALLEGION TO PROVIDE ALL HARDWARE TO EXTERIOR DOORS. INTENT IS FOR DOOR TO HAVE CARD READER ACCESS. INSTALLATION TO BE COMPLETED BY CONTRACTOR. R2. PROVIDE CRL ALL GLASS PANIC BOTTOM MOUNT HANDLE PA110 ON PUSH SIDE OF DOOR. ON TENANT SIDE, PROVIDE FULL HEIGHT LADDER PULL. DOOR TO BE DELAYED EGRESS PER IBC 2012. DOOR TO RECEIVE MAGLOCK, CLOSER, AND CARD READER (BY OWNER). R3. PROVIDE 8'-0" W X 7'-6"H DRYWALL OPENING WITH WALL MOUNTED HARDWARE REQUIRED FOR SLIDING "BARN" DOOR ASSEMBLY. PROVIDE BOTTOM CATCH AND STOP AS REQUIRED. CONTRACTOR TO PROVIDE CUT SHEETS FOR TENANT APPROVAL PRIOR TO ORDERING. DESIGN INTENT IS FOR MOUNTING HARDWARE TO BE ABOVE DOOR OPENING AND DOOR TO EXTEND TO FLOOR. CONTRACTOR TO WORK WITH SDI TO ENSURE THIS INTENT IS MET. PROVIDE 5' LONG ROCKWOOD OVALTEK-TEK STAINLESS STEEL PULL ON BOTH SIDES. R4. PROVIDE NEW WOOD FLUSH BEAD LITE KIT TO MATCH DOOR TYPE "D3". FLUSH BEAD TRIM TO MATCH DOOR STAIN EXACTLY. R5. "TESTING" RESIDENTIAL TYPE WOOD DOOR TO BE PREPPED FOR RESIDENTIAL DEADBOLT AND LEVER, COORDINATE WITH TENANT ON EXACT REQUIREMENTS. R6. "TESTING" FRAME TO BE PREPPED WITH LE-LOCK, COORDINATE WITH TENANT ON EXACT REQUIREMENTS. ALLEGION TO PROVIDE DOOR. COORDINATE EXACT FRAME WITH ALLEGION. R7. "TESTING" DOOR/FRAME TO BE ALUMINUM PREPPED FOR 99 RIM X 996 TRIM EXIT. COORDINATE WITH TENANT ON EXACT REQUIREMENTS. R8. PROVIDE ALTERNATE PRICE FOR 1 2" TEMPERED FULL GLASS BARN DOOR ASSEMBLY. PROVIDE PULLS ON BOTH SIDES OF DOOR AND SLIDING BARN DOOR TRACK AS SPECIFIED IN "R3" IF ACCEPTABLE FOR FULL GLASS DOORS. IF NOT, PROVIDE SIMILAR SUBSTITUTE. GENERAL NOTES: 1. ALL EXTERIOR DOORS TO BE PROVIDED AND INSTALLED BY CONTRACTOR, ALLEGION TO PROVIDE ALL HARDWARE TO EXTERIOR DOORS. 2. ALLEGION TO PROVIDE NEW ALL INTERIOR DOOR HARDWARE AND INSTALLED BY CONTRACTOR. 3. SEE ELECTRICAL PLAN (NOTE E01) FOR LOCATIONS OF TENANT PROVIDED CARD READERS. CONTRACTOR TO PROVIDE HARDWARE AND POWER AS REQUIRED. 4. ALL EXISTING DOOR FRAMES TO BE PAINTED TO MATCH TIMELY CHARCOAL. 5. ALLEGION PROVIDED HARDWARE INCLUDES ALL LEVERS, HINGES, ETC. STAIN TO MATCH EXIST. F1 TIMELY LAOCRAHC 3'-0"x7'-10"x13 4" D3 SOLID CORE BIRCH VNR. PS STAIN TO MATCH EXIST. F1 TIMELY LAOCRAHC 3'-0"x7'-10"x13 4" D3 SOLID CORE BIRCH VNR. PS STAIN TO MATCH EXIST. F1 TIMELY LAOCRAHC 3'-0"x7'-10"x13 4" D3 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F1 TIMELY LAOCRAHC SEE REMARK EXISTING -- -- -- -- -- -- EXISTING -- -- -- -- -- -- EXISTING -- -- -- -- -- -- -- -- 3'-0"x7'-10"x13 4" 3'-0"x7'-10"x13 4" 3'-0"x7'-10"x13 4" D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F1 TIMELY LAOCRAHC F1 TIMELY LAOCRAHC F1 TIMELY LAOCRAHC F1 TIMELY LAOCRAHC F1 TIMELY LAOCRAHC 0 1' 2' 4' RESTROOM ALCOVE A211 2 CERAMIC TILE MFG: ATLAS CONCORD SIZE: 24" X 24" COLOR: CALACATTA EXTRA UNPOLISHED INSTALLATION: MONOLITHIC GROUT: TEC POWER GROUT 934 DELOREAN GRAY (1 8" JOINT) NOTE: CONTACT TRACEY KESSENS (LOUISVILLE TILE) FOR MORE INFORMATION (317)366-2835 WALL BASE MFG: JOHNSONITE TYPE: 4" VINYL COVE, 1 8" GAUGE COLOR: BURNT UMBER 63 PAINT / WALLCOVERING MISCELLANEOUS MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: BENJAMIN MOORE BARREN PLAIN 2111-60 FINISH: EGGSHELL MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 9170 ACIER FINISH: EGGSHELL MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: BENJAMIN MOORE ELECTRIC ORANGE 2015-10 FINISH: EGGSHELL CARPET MFG: TANDUS TYPE: BROADLOOM CARPET PATTERN: REVERB II 44024 COLOR: RADIOGRAPH 02770 NOTE: CONTACT DOUG EDWARDS FOR SPECIAL PRICING (317)443-9579 MFG: PATCRAFT TYPE: MODULAR FACET PATTERN: MIXED MATERIALS CONVERGE - CUBE AND COLOR COLOR: 75% - CLOVE 00180 15% - TANGERINE 00650 10% - LEMON 00250 INSTALLATION: RANDOM TRIM PEICES MFG: SCHLUTER (FINISH TRIM ATOP ALL CB1 LOCATIONS) STYLE: JOLLY COLOR: STAINLESS STEEL NOTE: INSTALL ALL SCHLUTER EDGING TRIM PIECES TO BE FLUSH WITH ADJACENT TILE SURFACE, WITH NO OVERHANG. CONTRACTOR RESPONSIBLE FOR SELECTING PROPER TRIM THICKNESS. DESIGNER TO APPROVE SAMPLE PRIOR TO INSTALLATION. SEE DETAIL 3/A211 FOR MORE INFORMATION. DELETED DRY ERASE WALLCOVERING: MFG: KOROSEAL WALLTALKERS TYPE/ COLOR: DRYERASE/MAGNETIC (WHITE) NOTE: MUST BE INSTALLED BY CERTIFIED INSTALLER. DRYWALL MUST BE PREPARED TO LEVEL OF FINISH AS RECOMMENDED BY MANUFACTURER PRIOR TO INSTALLATION OF PRODUCT. PRODUCT TO BE INSTALLED RAILROADED. CONTACT: MANUFACTURER FOR INSTALLATION CERTIFICATION AND RECOMMENDATIONS, PRICING AND KIT SIZES MFG: ATLAS CONCORD SIZE: 24" WIDE - HEIGHT TO MATCH EXISTING TILE BASE COLOR: CALACATTA EXTRA UNPOLISHED INSTALLATION: ALIGN GROUT JOINTS WITH ADJACENT FLOOR TILE GROUT: TEC POWER GROUT 934 DELOREAN GRAY (1 8" JOINT) NOTE: SEE DETAIL 3/A211 1. ALL EXISTING TIMELY AND/OR HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH TIMELY - CHARCOAL. 2. ALL FIRE EXTINGUISHER CABINETS TO BE PAINTED TO MATCH ADJACENT WALL FINISH. PAINT TO BE SEMI-GLOSS FINISH. GENERAL NOTES NOT TO SCALE DETAIL - TILE TRIM A211 3 LUXURY VINYL TILE MFG: PATCRAFT PATTERN: METALLIX FACET I315V COLOR: 50% - ALUMINUM 00530 25% - PEWTER 0057O 25% - MOLTEN ORANGE 00650 INSTALLATION: RANDOM MFG: PATCRAFT PATTERN: METALLIX FACET I315V COLOR: 50% - ALUMINUM 00530 50% - PEWTER 0057O INSTALLATION: RANDOM PROVIDE TANDUS-CENTIVA METALEDGE STEEL #00179. VERIFY TRANSITION STRIP PROFILE IS APPROPRIATE FOR HEIGHT OF SPECIFIED FINISHES. USE LEVELING LATEX AS NEEDED SUCH THAT TOP OF LVT IS LEVEL WITH TOP OF CARPET PILE. CENTER TRANSITION ON END OF WALL WHEN APPLICABLE AS SHOWN. CONTRACTOR TO VERIFY TRANSITION STRIP SPECIFIED IS APPROPRIATE FOR APPLICATION. CONSULT WITH SDI UPON DETERMINATION. PROVIDE ALTERNATE PRICE FOR COMMERCIAL GRADE EPOXY FLOOR OVER EXISTING CONCRETE. REMOVE ANY IMPERFECTIONS IN EXISTING CONCRETE TO ALLOW FOR SMOOTH APPLICATION OF EPOXY FLOORING. DESIGN INTENT IS FOR ANTI-SLIP FINISH. COLOR: TBD. TRANSITION FROM EPOXY FLOORING TO CARPET TO BE TANDUS CENTIVA METALEDGE DEUX TRIM #MET02 STEEL #00179. BASE BID TO INCLUDE LVT2. DESIGN INTENT IS TO MITRE OUTSIDE CORNER OF EXISTING CB1 AND NEW CB1. ALTER AS REQUIRED TO CREATE SEAMLESS TRANSITION. FINISH NEW WALL TO MATCH EXISTING PAINT AND VINYL BASE. PROVIDE SCHLUTER SCHIENE TRANSITION STRIP, FINISH: BRUSHED STAINLESS STEEL (EB), BETWEEN NEW MOSAIC TILE AND EXISTING RESTROOM TILE. PROVIDE ALTERNATE PRICE FOR WC1, WHERE INDICATED ON WALL. PAINT TO BE IN BASE BID. INSTALL TILE IN SAME DIRECTION AS EXISTING TILE IN LOBBY AND BREAK AREA. ALIGN 2 SPECIALTY FLOORING MFG: ARMSTRONG (ALTERNATE PRICE) PATTERN: STATIC DISSIPATIVE TILE COLOR: TBD INSTALLATION: ADHESIVE TO HAVE APPROPRIATE COPPER GROUNDING STRIPS 2 2 2 2 +72" TV DED 6x5 6x5 LF LF LF LF LF LF LF LF LF P P J 4x3 6x5 6x5 6x5 6x5 6x5 6x5 LF LF LF LF P P OFFICE 107 OFFICE 109 ENTRY 101 DISPLAY CASE 6x5 6x5 6x5 6x5 6x5 6x5 LF ADVANCED DEVE. AREA 102 TESTING 108 6x5 6x5 LF LF PLOTTER TV LF INDUSTRIAL DESIGN MEETING AREA 104 ID LAB 105 FLEX SPACE 106 LF LF INDUSTRIAL DESIGN AREA 103 VF VF VF VF 6x5 LF LF 6x5 6x5 6x5 TV TV CONFERENCE 141 J J J +72" +72" DED +72" +72" P +72" +72" +72" +72" TV DED 6x5 6x5 LF LF LF LF LF LF LF LF LF P P J 4x3 6x5 6x5 6x5 6x5 6x5 6x5 LF LF LF LF ELN S N3 S N3 S3ND S N3 S N3 S N3 S N3 S N3 S N3 ELN ELN ELN ELN ELN SND S 3ND N S ELN S N3 S N3 S3ND S N3 S N3 S N3 S N3 S N3 S N3 ELN ELN ELN ELN ELN SND S 3ND N S REFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 10.11.17 REVIEW SET 10.13.17 PERMIT SET 11.09.17 BID SET REVISIONS MARK DATE DB DESCRIPTION 11.10.17 AM REV1 11.30.17 AM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com ALLEGION ENGINEERING 11805 N. PENNSYLANNIA ST. - 1ST FLOOR CARMEL, IN 46032 MMS/ACM MMS 2017.280 1ST FLOOR 0 2' 4' 8' 16' N 2 1 AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN POWER POLE FOR ELECTRICAL AND DATA. PROVIDE JUNCTION BOX ABOVE CEILING. POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX ELECTRICAL PLAN/ A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION GENERAL RCP NOTES CEILING PLAN NOTES MECHANICAL NOTES EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GENERAL ELEC. NOTES PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE COPIER RECEPTACLE WITH TENANT AND FURNITURE VENDOR. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. DESIGN INTENT IS FOR COPIER TO BE FED FROM WORKSTATIONS FOR POWER AND DATA IF POSSIBLE. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE POWER AND DATA FOR POWER POLE. VERIFY ELECTRIC REQUIREMENTS WITH TENANT PRIOR TO INSTALLING. POWER POLE PROVIDED BY CONTRACTOR AND TO MATCH BUILDING STANDARD POWER POLE STYLE AND COLOR. PROVIDE POWER AND DATA AT 72" A.F.F. FOR TENANT'S WALL MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE 1 1 4" CONDUIT IN WALL. COORDINATE POWER REQUIREMENTS FOR TENANT PROVIDED PLOTTER, PROVIDE DEDICATED POWER AS NEEDED. PROVIDE WIRE MOLD ALONG EXTERIOR PERIMETER OF ROOM. COORDINATE WITH TENANT FOR EXACT QUANTITY OF OUTLETS WITH TENANT. COORDINATE EXACT LOCATION AND HEIGHT WITH TENANT. WIRE MOLD TO HAVE POWER ONLY, NO DATA REQUIRED. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE WIRE MOLD ALONG EXTERIOR WALL AT BACK OF WORK SURFACE TO HOLD (4) POWER OUTLETS. COORDINATE EXACT LOCATION AND HEIGHT WITH TENANT. WIRE MOLD TO HAVE POWER ONLY, NO DATA REQUIRED. COORDINATE WITH TENANT IF ADDITIONAL POWER IS REQUIRED IN ELECTRICAL ROOM. PROVIDE POWER FOR OWNER PROVIDED DISPLAY CASE. COORDINATE REQUIREMENTS WITH OWNER. 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. CONTROL ID LAB LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. CONTROL FLEX SPACE LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. CONTROL TESTING LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE 2"H X 4"W DRYWALL BULKHEAD AND STRUCTURAL SUPPORT IN CEILING AS REQUIRED TO SUPPORT HERCULITE DOOR AND FRAMELESS GLASS SYSTEM. COORDINATE EXACT LOCATION AND HEIGHT OF LINEAR PENDANT WITH SDI PRIOR TO INSTALLATION. 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO MATCH BUILDING STANDARD. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 5. ALL WIRELESS ACCESS PRODUCTS AND INSTALLATION TO BE COORDINATED BY ALLEGION. J J B O J +42" 1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. EXISTING GRID IS 2'x2' AT 8'-0" A.F.F. PROVIDE NEW CEILING TILES THROUGHOUT TO MATCH BUILDING STANDARD: 2'x2' ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE WITH NEW AS REQUIRED. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO MATCH BUILDING STANDARD. REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. PROVIDE ALTERNATE PRICE TO REPLACE ALL EXISTING SWITCHES TO DIMMER SWITCH AND ALL NEW SWITCHING TO BE DIMMABLE. LIGHT CIRCUIT EXIT LIGHT FIXTURE DELETED LIGHT FIXTURE, 2'x4', MOBERN MFPEL24LED50DMVWH40 LED EDGELIT FLAT PANEL - CONTACT PATRICK MCDOWELL FOR INFORMATION (317)697-1983 NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC LEGEND RECESSED LIGHT FIXTURE, INCANDESCENT SWITCH, PROJECTOR SCREEN LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH SWITCH, PROJECTOR SCREEN LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH SWITCH, GARBAGE DISPOSAL SWITCH, GARBAGE DISPOSAL LIGHT FIXTURE, 2'x2', GMAX LEDPANEL 40 4000K - CONTACT PATRICK MCDOWELL FOR INFORMATION (317)697-1983 EXISTING/RELOCATED DIFFUSER, LAY-IN, 4"x4' EXISTING/RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. FOR PROJECTS REQUIRING STATE DESIGN REVIEW, HVAC DIFFUSER RELOCATIONS ARE TO BE REVIEWED/RELEASED AS PART OF THE ARCHITECTURAL SCOPE OF WORK. CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' GYPSUM BOARD CEILING - PAINT EXIST. GYPSUM BOARD CEILING WAC LIGHTING E=EM² - MODEL: PD-457 dwelLED LED LINEAR PENDANT, BRUSHED ALUMINUM FINISH. CONTACT PATRICK MCDOWELL FOR INFORMATION (317)697-1983 LIGHT FIXTURE, PENDANT LIGHT FIXTURE, LED - VODE ZIP TWO 707 - PERPENDICULAR TO T-BAR - CONTACT PATRICK MCDOWELL FOR INFORMATION (317)697-1983 1 2 2 2 2 2 2 2 2 14'-3" 4'-0" (CLEAR) FE (24 x 36 OPEN WALL SPACE) 12" DEEP ADJUSTABLE GLASS SHELVES (DOUG MOCKETT SH14 SETS WITH 2X C-STYLETRACKS, 5 1 2" BRACKETS) 3'-0" 5'-8" EQ. EQ. VINYL BASE 1'-4" 3'-0" 2'-0" 9" 1'-0" 3'-0" ARCHITECTURAL FLOOR PLAN NOT TO SCALE A111 WALL AT MULLION DETAIL AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL STANDARD WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING W1 W2 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. A111 1 DATE DESCRIPTION ISSUE 10.11.17 REVIEW SET 10.13.17 PERMIT SET 11.09.17 BID SET REVISIONS MARK DATE DB DESCRIPTION 11.10.17 AM REV1 11.30.17 AM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com ALLEGION ENGINEERING 11805 N. PENNSYLANNIA ST. - 1ST FLOOR CARMEL, IN 46032 MMS/ACM MMS 2017.280 1ST FLOOR 0 2' 4' 8' 16' N 2 1 DEMOLITION PLAN REMOVE EXISTING ENTRY DOOR AND ADJACENT EXTERIOR GLAZING. COORDINATE WITH OWNER/MANUFACTURER FOR NEW DOOR REQUIREMENTS NECESSARY FOR EXTERIOR APPLICATION. REMOVE EXISTING WALL AS REQUIRED FOR NEW DOOR INSTALLATION. SALVAGE EXISTING FIRE EXTINGUISHER CABINET FOR REINSTALLATION. REMOVE EXISTING WALL CONSTRUCTION TO CORNER. REPAIR EXISTING ADJACENT WALL CONSTRUCTION AS REQUIRED. SALVAGE EXISTING LED LIGHT FIXTURE FOR RELOCATION. REFER TO CEILING PLAN FOR FURTHER INFORMATION. DEMOLITION PLAN NOTES ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME CEILING GRID AND TILES, 2'x4' SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT EXIT LIGHT DEMOLITION LEGEND AREA NOT IN CONTRACT AREA OF WORK DEMOLITION PLAN/ 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. CONFIRM THAT ALL EXISTING WALLS ARE FULLY INSULATED. IF NOT, PROVIDE NEW INSULATION AS REQUIRED. PROVIDE 2' OF INSULATION ABOVE CEILING ON EITHER SIDE OF WALL. 3. ALL WALLS RECEIVING PT2 OR DRY ERASE WALLCOVERING (WC1) SHALL RECEIVE LEVEL 5 DRYWALL FINISH. REFER TO SHEET A211 FOR LOCATIONS. 4. PROVIDE ALTERNATE COST TO EXTEND ALL WALLS SURROUNDING OFFICES AND CONFERENCE ROOMS TO DECK. GENERAL NOTES PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. COORDINATE WITH TENANT ON EXACT SINK REQUIREMENT AND SPECIFICATION. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NOT USED. NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. IF FIRE EXTINGUISHER IS EXISTING, CONTRACTOR TO ENSURE IT IS IN PROPER WORKING ORDER OR PROVIDE NEW AS NEEDED. REUSE SALVAGED FIRE EXTINGUISHERS FROM DEMOLITION IF POSSIBLE. PROVIDE BLOCKING IN WALL OR BLACK MELAMINE BACKER BOARD FOR TENANT PROVIDED FLAT SCREEN TV. CONFIRM WITH TENANT ON EXACT LOCATION AND HEIGHT. PROVIDE FRAMELESS SIDELITE WITH 4" SIDELITE STAINLESS STEEL TOP AND BOTTOM RAIL SIMILAR TO D2. NOTE GLASS RUNS STRAIGHT TO FLUSH WALL CORNER AND THERE IS NO 4" WING WALL. PROVIDE BLOCKING AS REQUIRED FOR BARN DOOR ASSEMBLY. REFER TO SHEET A211 FOR FURTHER INFORMATION. PROVIDE BLOCKING AS REQUIRED FOR OWNER PROVIDED GLASS MARKER BOARDS. CONFIRM INSTALLATION LOCATION WITH OWNER. SINGLE BASIN MOLDED PLASTIC UTILITY SINK. PROVIDE CUT SHEETS TO OWNER FOR APPROVAL. ARCHITECTURAL PLAN NOTES 0 2' 4' 8' 16' TYP. A111 1 1. REMOVE UPGRADED PROFILE CEILING TILE THROUGH HALLWAY. REFER TO CEILING PLAN FOR FURTHER INFORMATION. 2. WHERE EXISTING LIGHT FIXTURE INTERSECTS WITH GRID, REPAIR GRID TO "LIKE NEW CONDITION". DEMOLITION GENERAL NOTES 0 1' 2' 4' ELEVATION A111 2 A111 2 1 109 STG. 104 JANITOR 105 MICRO REFRIG MICRO 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 6x5 5x3 5x3 6x5 6x5 5x3 5x3 x MOTHERS 124 10'-0" 8'-0" x SPRINKLER 121 15'-1" 5'-0" x OFFICE 134 14'-10" 11'-7" x OFFICE 138 14'-10" 11'-11" x OFFICE 127 x 11'-7" 15'-6" OFFICE 128 x 11'-7" 15'-6" OFFICE 131 11'-7" 15'-6" OPEN OFFICE 126 COPY 130 COPY 125 x CONFERENCE 116 14'-0" 19'-5" x SHARED OFFICE 123 13'-2" 19'-5" x HUDDLE 118 9'-9" 13'-4" x QUIET ROOM 120 15'-1" 9'-11" x SERVER 122 13'-5" 11'-0" x SERVER 119 14'-4" 13'-4" x FOCUS 137 5'-8" 8'-0" x FOCUS 136 5'-11" 8'-0" 6x5 6x5 6x5 6x5 6x5 6x5 5x3 6x5 6x5 6x5 6x5 x HUDDLE 114 6'-7" 11'-3" VEND. VEND. FE FE FE EL EL x VESTIBULE 100 25'-0" 10'-10" x BREAK 139 19'-7" 13'-2" ELN ELN ELN ELN ELN ELN ELN ELN ELN ICE x OFFICE 107 11'-0" 11'-9" x OFFICE 109 11'-0" 11'-9" ENTRY 101 DISPLAY CASE 6x5 6x5 6x5 6x5 6x5 6x5 LF ADVANCED DEVE. AREA 102 TESTING 108 6x5 6x5 LF LF LF x INDUSTRIAL DESIGN MEETING AREA 104 18'-2" 11'-9" x ID LAB 105 14'-10" 11'-11" x FLEX SPACE 106 14'-11" 22'-4" LF LF INDUSTRIAL DESIGN AREA 103 567 SF VF VF VF VF 6x5 LF LF 6x5 6x5 6x5 x CONFERENCE 141 18'-1" 12'-1" FE ELN ELN ELN ELN ELN 6x5 6x5 LF LF LF LF LF LF LF LF LF 4x3 6x5 6x5 6x5 6x5 6x5 6x5 LF LF LF LF FE LIFE SAFETY LIFE SAFETY PLAN L100 DATE DESCRIPTION ISSUE 10.11.17 REVIEW SET 10.13.17 PERMIT SET 11.09.17 BID SET REVISIONS MARK DATE DB DESCRIPTION 11.10.17 AM REV1 11.30.17 AM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com ALLEGION ENGINEERING 11805 N. PENNSYLANNIA ST. - 1ST FLOOR CARMEL, IN 46032 MMS/ACM MMS 2017.280 1ST FLOOR N 2 1 0 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK LIFE SAFETY NOTES GENERAL NOTES SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 20,024 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 47 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE A121) BUILT BEFORE 1978? NO 4,626 4,626 20,024 1 20,024 47 BUILDING CONSTRUCTION TYPE II-B 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN - MATCH BUILDING STANDARD FE EMERGENCY LIGHT - MATCH BUILDING STANDARD FE TRAVEL DISTANCE NUMBER OF EXITS REQUIRED: 1 PROVIDED: 4 EP EX EX EX BUSINESS TRAVEL DISTANCE = 145' EX EP DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. 4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I. 10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. 15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS. 17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVER PLATE. 18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED. 19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS). MECHANICAL & ELECTRICAL NOTES 1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS 3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. 5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET). 6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. 8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT. 12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. FINISH NOTES 1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. 8. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS (CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY). 9. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. MILL/CASEWORK NOTES 1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS. 2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS. 4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. 6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. 8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 300.21. 11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. DEMOLITION NOTES VICINITY MAP NOT TO SCALE NOT TO SCALE KEY PLAN - 1ST FLOOR 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE . 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. 3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. 5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC. 6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE. 14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. 17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 20. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK. 27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. 32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON L100 IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. FIRE PROTECTION NOTES N T111 COVER SHEET AND GENERAL PROJECT NOTES L100 LIFE SAFETY PLAN A111 DEMOLITION PLAN & ARCHITECTURAL FLOOR PLAN A121 REFLECTED CEILING PLAN: HVAC / LIGHTING / ELECTRICAL PLAN A211 DOOR SCHEDULE / INTERIOR DETAILS / FINISH PLAN INDEX OF DRAWINGS = AREA OF WORK