HomeMy WebLinkAboutAllegion Bid Set REV2 11.30.17MICRO
REFRIG
MICRO
VEND. VEND.
ICE
COVER SHEET AND
GENERAL NOTES
T111
DATE DESCRIPTION
ISSUE
10.11.17 REVIEW SET
10.13.17 PERMIT SET
11.09.17 BID SET
REVISIONS
MARK DATE DB DESCRIPTION
11.10.17 AM REV1
11.30.17 AM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
ALLEGION
ENGINEERING
11805 N. PENNSYLANNIA ST. - 1ST FLOOR
CARMEL, IN 46032
MMS/ACM MMS
2017.280
1ST FLOOR
DOCUMENT APPROVAL
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
___________________________________ _____________________________________________ _____________________________________________ ___________
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT.
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
GENERAL PROJECT NOTES
1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
BASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE
DESIGN-BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY
FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR
PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL
INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL,
ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL
APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM
SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND
MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR
COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS.
2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
6x5
6x5
6x5
6x5 6x5
6x5
6x5
6x5
6x5 6x5
6x5
6x5
6x5
6x5
6x5 6x5
6x5
6x5
6x5
6x5
6x5
6x5
x
ELECTRICAL
133
11'-5" 13'-4"
6x5
6x5
6x5 6x5
6x5
6x5
6x5
x
CONFERENCE
108
x 12'-8" 18'-11"
CONFERENCE
103
24'-6" 14'-10"
x
CONFERENCE
102
24'-6" 16'-4"
WOMEN
MEN 107
106
x
OFFICE
113
13'-7" 11'-2"
x
CONFERENCE
132
18'-1" 11'-8"
OPEN OFFICE
129
OPEN OFFICE
135
OPEN OFFICE
112
ENTRY
101
COPY
WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
FE
EL
OFFICE
107
OFFICE
109
ENTRY
101
ADVANCED
DEVE. AREA
102
TESTING
108
INDUSTRIAL DESIGN
MEETING AREA
104
ID LAB
105
FLEX
SPACE
106
INDUSTRIAL
DESIGN AREA
103
22'-83
4"
4'-5
3
4"
(CLEAR)
21'-51
4"
CONFERENCE
141
FE
10'-113
4"
8'-21
4"
EQ. 8'-0" EQ.
P
P
OFFICE
107
OFFICE
109
ENTRY
101
DISPLAY
CASE
6x5
6x5
6x5
6x5
6x5
6x5
LF
ADVANCED
DEVE. AREA
102
TESTING
108
6x5 6x5
LF LF PLOTTER
TV
LF
INDUSTRIAL DESIGN
MEETING AREA
104
ID LAB
105
FLEX
SPACE
106
LF LF
INDUSTRIAL
DESIGN AREA
103
VF VF VF VF
6x5
LF
LF
6x5
6x5
6x5
TV TV
CONFERENCE
141
J
J
J
+72"
+72"
DED
+72"
+72"
P
+72"
+72"
+72"
EXIST
4"V.
EXIST
4"W.
2"W.
F.F.
2"W.
2"W.
SINK
TO
BUILDING
DRAIN
F.F.
11
2"V.
CLG.
11
2"V.
CLG.
TO EXISTING
STACK
TILE
CUT TILE AS
SCHEDULED
SILICONE
TRIM PIECE (TR1)
DRYWALL
TILE
6"
F1
8'-0"
2"
3'-0"
3'-4"
2" 2"
7'-10" 7'-10"
D1
3'-0"
3'-8" 8"
8"
7'-10"
3'-0"
D3
1
4" TEMPERED
GLASS
1'-8"
1/2" TEMPERED
GLASS
8'-0"
3'-0" 3'-6"
4" STAINLESS STEEL
TOP RAIL
4" STAINLESS STEEL
BOTTOM RAIL
PROVIDE ONE PULL ON
EACH SIDE OF DOOR
(TOTAL COUNT 2), AS
NOTED IN REMARKS
D2
4'-2"
8'-0"
7'-8"
7'-6"
SLIDING DOOR
HARDWARE
AS SCHEDULED,
TOP TRACK
8'-0"W x 7'-6"H
DRYWALL
WRAPPED
OPENING
4'-2"
D4
5' LONG PULL
AS NOTED IN
REMARK
OFFICE
107
OFFICE
109
ENTRY
101
ADVANCED
DEVE. AREA
102
TESTING
108
INDUSTRIAL DESIGN
MEETING AREA
104
ID LAB
105
FLEX
SPACE
106
INDUSTRIAL
DESIGN AREA
103
CONFERENCE
141
8" 8"
8"
7'-10"
3'-0"
D5
1
4" TEMPERED
GLASS
DOOR SCHEDULE
INTERIOR DETAILS
A211
NOTE: REFER TO FLOORPLAN
FOR SINK LOCATIONS.
DATE DESCRIPTION
ISSUE
10.11.17 REVIEW SET
10.13.17 PERMIT SET
11.09.17 BID SET
REVISIONS
MARK DATE DB DESCRIPTION
11.10.17 AM REV1
11.30.17 AM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
ALLEGION
ENGINEERING
11805 N. PENNSYLANNIA ST. - 1ST FLOOR
CARMEL, IN 46032
MMS/ACM MMS
2017.280
1ST FLOOR
2
1
FINISH PLAN NOTES
AREA NOT IN CONTRACT AREA OF WORK
FINISH PLAN
FINISH PLAN/
FLOOR COVERINGS
LEGEND
PROVIDE SCHLUTER SCHIENE TRANSITION STRIP AT CARPET TO TILE TRANSITION,
FINISH: BRUSHED STAINLESS STEEL (EB). PROVIDE LEVELING LATEX UNDER CARPET AS
SUCH THAT TOP OF FINISHES ARE LEVEL. SEAM SEAL CARPET EDGES. TRANSITION
STRIP MUST BE LEVEL WITH OR SLIGHTLY HIGHER THAN TILE EDGE. TRANSITION
PROFILE MUST BE APPROPRIATE FOR FLOORING MATERIALS AND MUST BE SUBMITTED
TO SDI FOR FINAL APPROVAL PRIOR TO INSTALLATION.
EXISTING WALL FINISH TO REMAIN.
INSTALL DRY ERASE WALLCOVERING WC1, FROM 36" TO 84" A.F.F. WALL FINISH
ABOVE AND BELOW TO BE PAINTED. PROVIDE 1 1/2" ANODIZED ALUMINUM TRIM AT
TOP AND BOTTOM EDGE OF WALLCOVERING. PROVIDE 48" WIDE ANODIZED
ALUMINUM MARKER TRAY CENTERED ON BOTTOM TRIM. PROVIDE ALTERNATE PRICE
TO INSTALL WC1 FULL HEIGHT.
SEAM SEAL ALL CUT CARPET EDGES.
TRANSITION TO OCCUR 35'-0" FROM CORNER OUTSIDE OFFICE 113 AS SHOWN ON
PLAN. DESIGN INTENT IS FOR AREA WITH TILES TO BEGIN ON NORTH SIDE WITH FULL
PLANK AND END ON SOUTH SIDE WITH FULL PLANK. ADJUST SOUTH SIDE TRANSITION
AS REQUIRED.
EDGE OF CARPET TO ALIGN WITH EDGE OF WALL.
PROVIDE VERTICAL ANODIZED ALUMINUM TRIM AT TOP OF EXPOSED EDGE OF
WALLCOVERING.
TYPICAL ALL SINGLE LOCATIONS,NOT TO SCALE
RISER DIAGRAM
A211
1
0 2' 4' 8' 16'
DOOR SCHEDULE
# DIMENSIONS DOOR FRAME HARDWARE REM.
01 R2
02 DRYWALL WRAPPED
OPENING 8R ,3R
03
04
05
06A NEW SEE REMARKS SEE REMARKS R1
06B PS, CL
07 R4
08A CASED OPENING
08B R5
08C R6
08D R7
08E CASED OPENING
09 R4
41 R4
CL CLOSER
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
DB DEADBOLT
DL DUMMY LEVER
EL ELECTROMAGNETIC LOCK (PER IBC 2012)
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
H HOLD OPEN
KP KICK PLATE
KS KICK STOP
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
HARDWARE LEGEND
HERCULITE SYSTEM D2 HERCULITE GLASS SYSTEM -- -- -- SEE REMARK
D4
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST. SEE REMARK
3'-0"x7'-10"x13
4" D5
SOLID CORE
BIRCH VNR.
DRYWALL WRAPPED OPENING
PS
REMARKS
TYPE MATERIAL FINISH TYPE MATERIAL FINISH
DOOR/FRAME TYPES
DOOR/FRAME NOTES
1. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE; TOUCH UP EXISTING
DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS
MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO
MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL
LOCKSETS.
2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW
DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD.
PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE
EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING
REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
R1. NEW EXTERIOR STOREFRONT DOUBLE DOOR TO BE INTEGRATED INTO
EXISTING STOREFRONT. INTENT IS TO MATCH EXISTING MATERIALS/FINISHES.
PROVIDE ALL NECESSARY SWEEPS, SEALS, HARDWARE, THRESHOLDS, ETC
AS REQUIRED FOR EXTERIOR DOOR. DOOR TO HAVE TENANT PROVIDED
CARD READER. DOOR STYLE TO HAVE 6" STYLE, 6" TOP RAIL, 10" MIN.
BOTTOM RAIL, FULL GLASS. CONTACT KEVIN MORGAN FOR
REQUIREMENTS (317)715-4506. ALLEGION TO PROVIDE ALL HARDWARE
TO EXTERIOR DOORS. INTENT IS FOR DOOR TO HAVE CARD READER
ACCESS. INSTALLATION TO BE COMPLETED BY CONTRACTOR.
R2. PROVIDE CRL ALL GLASS PANIC BOTTOM MOUNT HANDLE PA110 ON
PUSH SIDE OF DOOR. ON TENANT SIDE, PROVIDE FULL HEIGHT LADDER
PULL. DOOR TO BE DELAYED EGRESS PER IBC 2012. DOOR TO RECEIVE
MAGLOCK, CLOSER, AND CARD READER (BY OWNER).
R3. PROVIDE 8'-0" W X 7'-6"H DRYWALL OPENING WITH WALL MOUNTED
HARDWARE REQUIRED FOR SLIDING "BARN" DOOR ASSEMBLY. PROVIDE
BOTTOM CATCH AND STOP AS REQUIRED. CONTRACTOR TO PROVIDE
CUT SHEETS FOR TENANT APPROVAL PRIOR TO ORDERING. DESIGN INTENT
IS FOR MOUNTING HARDWARE TO BE ABOVE DOOR OPENING AND DOOR
TO EXTEND TO FLOOR. CONTRACTOR TO WORK WITH SDI TO ENSURE THIS
INTENT IS MET. PROVIDE 5' LONG ROCKWOOD OVALTEK-TEK STAINLESS
STEEL PULL ON BOTH SIDES.
R4. PROVIDE NEW WOOD FLUSH BEAD LITE KIT TO MATCH DOOR TYPE
"D3". FLUSH BEAD TRIM TO MATCH DOOR STAIN EXACTLY.
R5. "TESTING" RESIDENTIAL TYPE WOOD DOOR TO BE PREPPED FOR
RESIDENTIAL DEADBOLT AND LEVER, COORDINATE WITH TENANT ON
EXACT REQUIREMENTS.
R6. "TESTING" FRAME TO BE PREPPED WITH LE-LOCK, COORDINATE WITH
TENANT ON EXACT REQUIREMENTS. ALLEGION TO PROVIDE DOOR.
COORDINATE EXACT FRAME WITH ALLEGION.
R7. "TESTING" DOOR/FRAME TO BE ALUMINUM PREPPED FOR 99 RIM X 996
TRIM EXIT. COORDINATE WITH TENANT ON EXACT REQUIREMENTS.
R8. PROVIDE ALTERNATE PRICE FOR 1
2" TEMPERED FULL GLASS BARN
DOOR ASSEMBLY. PROVIDE PULLS ON BOTH SIDES OF DOOR AND
SLIDING BARN DOOR TRACK AS SPECIFIED IN "R3" IF ACCEPTABLE FOR
FULL GLASS DOORS. IF NOT, PROVIDE SIMILAR SUBSTITUTE.
GENERAL NOTES:
1. ALL EXTERIOR DOORS TO BE PROVIDED AND INSTALLED BY
CONTRACTOR, ALLEGION TO PROVIDE ALL HARDWARE TO
EXTERIOR DOORS.
2. ALLEGION TO PROVIDE NEW ALL INTERIOR DOOR HARDWARE AND
INSTALLED BY CONTRACTOR.
3. SEE ELECTRICAL PLAN (NOTE E01) FOR LOCATIONS OF TENANT
PROVIDED CARD READERS. CONTRACTOR TO PROVIDE HARDWARE
AND POWER AS REQUIRED.
4. ALL EXISTING DOOR FRAMES TO BE PAINTED TO MATCH TIMELY
CHARCOAL.
5. ALLEGION PROVIDED HARDWARE INCLUDES ALL LEVERS, HINGES,
ETC.
STAIN TO
MATCH EXIST. F1 TIMELY LAOCRAHC
3'-0"x7'-10"x13
4" D3
SOLID CORE
BIRCH VNR. PS
STAIN TO
MATCH EXIST. F1 TIMELY LAOCRAHC
3'-0"x7'-10"x13
4" D3
SOLID CORE
BIRCH VNR. PS
STAIN TO
MATCH EXIST. F1 TIMELY LAOCRAHC
3'-0"x7'-10"x13
4" D3
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST. F1 TIMELY LAOCRAHC
SEE REMARK
EXISTING -- -- -- -- -- --
EXISTING -- -- -- -- -- --
EXISTING -- -- -- -- -- --
--
--
3'-0"x7'-10"x13
4"
3'-0"x7'-10"x13
4"
3'-0"x7'-10"x13
4"
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
D1 SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F1 TIMELY LAOCRAHC
F1 TIMELY LAOCRAHC
F1 TIMELY LAOCRAHC
F1 TIMELY LAOCRAHC
F1 TIMELY LAOCRAHC
0 1' 2' 4'
RESTROOM ALCOVE
A211
2
CERAMIC TILE
MFG: ATLAS CONCORD
SIZE: 24" X 24"
COLOR: CALACATTA EXTRA UNPOLISHED
INSTALLATION: MONOLITHIC
GROUT: TEC POWER GROUT
934 DELOREAN GRAY (1
8" JOINT)
NOTE: CONTACT TRACEY KESSENS
(LOUISVILLE TILE) FOR MORE INFORMATION
(317)366-2835
WALL BASE
MFG: JOHNSONITE
TYPE: 4" VINYL COVE, 1
8" GAUGE
COLOR: BURNT UMBER 63
PAINT / WALLCOVERING
MISCELLANEOUS
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: BENJAMIN MOORE BARREN PLAIN 2111-60
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW 9170 ACIER
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: BENJAMIN MOORE ELECTRIC ORANGE 2015-10
FINISH: EGGSHELL
CARPET
MFG: TANDUS
TYPE: BROADLOOM CARPET
PATTERN: REVERB II 44024
COLOR: RADIOGRAPH 02770
NOTE: CONTACT DOUG EDWARDS FOR
SPECIAL PRICING (317)443-9579
MFG: PATCRAFT
TYPE: MODULAR FACET
PATTERN: MIXED MATERIALS CONVERGE -
CUBE AND COLOR
COLOR: 75% - CLOVE 00180
15% - TANGERINE 00650
10% - LEMON 00250
INSTALLATION: RANDOM
TRIM PEICES
MFG: SCHLUTER (FINISH TRIM ATOP ALL CB1 LOCATIONS)
STYLE: JOLLY
COLOR: STAINLESS STEEL
NOTE: INSTALL ALL SCHLUTER EDGING TRIM PIECES TO
BE FLUSH WITH ADJACENT TILE SURFACE, WITH NO
OVERHANG. CONTRACTOR RESPONSIBLE FOR
SELECTING PROPER TRIM THICKNESS. DESIGNER TO
APPROVE SAMPLE PRIOR TO INSTALLATION. SEE
DETAIL 3/A211 FOR MORE INFORMATION.
DELETED
DRY ERASE WALLCOVERING:
MFG: KOROSEAL WALLTALKERS
TYPE/ COLOR: DRYERASE/MAGNETIC (WHITE)
NOTE: MUST BE INSTALLED BY CERTIFIED INSTALLER.
DRYWALL MUST BE PREPARED TO LEVEL OF
FINISH AS RECOMMENDED BY MANUFACTURER
PRIOR TO INSTALLATION OF PRODUCT.
PRODUCT TO BE INSTALLED RAILROADED.
CONTACT: MANUFACTURER FOR INSTALLATION
CERTIFICATION AND RECOMMENDATIONS,
PRICING AND KIT SIZES
MFG: ATLAS CONCORD
SIZE: 24" WIDE - HEIGHT TO MATCH EXISTING TILE BASE
COLOR: CALACATTA EXTRA UNPOLISHED
INSTALLATION: ALIGN GROUT JOINTS WITH ADJACENT FLOOR TILE
GROUT: TEC POWER GROUT
934 DELOREAN GRAY (1
8" JOINT)
NOTE: SEE DETAIL 3/A211
1. ALL EXISTING TIMELY AND/OR HOLLOW METAL DOOR
FRAMES TO BE PAINTED TO MATCH TIMELY - CHARCOAL.
2. ALL FIRE EXTINGUISHER CABINETS TO BE PAINTED TO MATCH
ADJACENT WALL FINISH. PAINT TO BE SEMI-GLOSS FINISH.
GENERAL NOTES
NOT TO SCALE
DETAIL - TILE TRIM
A211
3
LUXURY VINYL TILE
MFG: PATCRAFT
PATTERN: METALLIX FACET I315V
COLOR: 50% - ALUMINUM 00530
25% - PEWTER 0057O
25% - MOLTEN ORANGE 00650
INSTALLATION: RANDOM
MFG: PATCRAFT
PATTERN: METALLIX FACET I315V
COLOR: 50% - ALUMINUM 00530
50% - PEWTER 0057O
INSTALLATION: RANDOM
PROVIDE TANDUS-CENTIVA METALEDGE STEEL #00179. VERIFY TRANSITION STRIP PROFILE
IS APPROPRIATE FOR HEIGHT OF SPECIFIED FINISHES. USE LEVELING LATEX AS NEEDED
SUCH THAT TOP OF LVT IS LEVEL WITH TOP OF CARPET PILE. CENTER TRANSITION ON END
OF WALL WHEN APPLICABLE AS SHOWN. CONTRACTOR TO VERIFY TRANSITION STRIP
SPECIFIED IS APPROPRIATE FOR APPLICATION. CONSULT WITH SDI UPON
DETERMINATION.
PROVIDE ALTERNATE PRICE FOR COMMERCIAL GRADE EPOXY FLOOR OVER EXISTING
CONCRETE. REMOVE ANY IMPERFECTIONS IN EXISTING CONCRETE TO ALLOW FOR
SMOOTH APPLICATION OF EPOXY FLOORING. DESIGN INTENT IS FOR ANTI-SLIP FINISH.
COLOR: TBD. TRANSITION FROM EPOXY FLOORING TO CARPET TO BE TANDUS CENTIVA
METALEDGE DEUX TRIM #MET02 STEEL #00179. BASE BID TO INCLUDE LVT2.
DESIGN INTENT IS TO MITRE OUTSIDE CORNER OF EXISTING CB1 AND NEW CB1. ALTER AS
REQUIRED TO CREATE SEAMLESS TRANSITION.
FINISH NEW WALL TO MATCH EXISTING PAINT AND VINYL BASE.
PROVIDE SCHLUTER SCHIENE TRANSITION STRIP, FINISH: BRUSHED STAINLESS STEEL (EB),
BETWEEN NEW MOSAIC TILE AND EXISTING RESTROOM TILE.
PROVIDE ALTERNATE PRICE FOR WC1, WHERE INDICATED ON WALL. PAINT TO BE IN
BASE BID.
INSTALL TILE IN SAME DIRECTION AS EXISTING TILE IN LOBBY AND BREAK AREA.
ALIGN
2
SPECIALTY FLOORING
MFG: ARMSTRONG (ALTERNATE PRICE)
PATTERN: STATIC DISSIPATIVE TILE
COLOR: TBD
INSTALLATION: ADHESIVE TO HAVE
APPROPRIATE COPPER GROUNDING STRIPS 2
2 2
2
+72"
TV
DED
6x5
6x5
LF LF
LF
LF
LF
LF
LF
LF
LF
P
P
J 4x3
6x5
6x5
6x5
6x5
6x5
6x5
LF LF LF LF
P
P
OFFICE
107
OFFICE
109
ENTRY
101
DISPLAY
CASE
6x5
6x5
6x5
6x5
6x5
6x5
LF
ADVANCED
DEVE. AREA
102
TESTING
108
6x5 6x5
LF LF PLOTTER
TV
LF
INDUSTRIAL DESIGN
MEETING AREA
104
ID LAB
105
FLEX
SPACE
106
LF LF
INDUSTRIAL
DESIGN AREA
103
VF VF VF VF
6x5
LF
LF
6x5
6x5
6x5
TV TV
CONFERENCE
141
J
J
J
+72"
+72"
DED
+72"
+72"
P
+72"
+72"
+72"
+72"
TV
DED
6x5
6x5
LF LF
LF
LF
LF
LF
LF
LF
LF
P
P
J 4x3
6x5
6x5
6x5
6x5
6x5
6x5
LF LF LF LF
ELN
S
N3
S
N3
S3ND
S
N3
S
N3
S
N3
S
N3
S
N3
S
N3
ELN
ELN
ELN
ELN
ELN
SND
S
3ND
N S
ELN
S
N3
S
N3
S3ND
S
N3
S
N3
S
N3
S
N3
S
N3
S
N3
ELN
ELN
ELN
ELN
ELN
SND
S
3ND
N S
REFLECTED
CEILING PLAN
A121
REFLECTED CEILING PLAN
DATE DESCRIPTION
ISSUE
10.11.17 REVIEW SET
10.13.17 PERMIT SET
11.09.17 BID SET
REVISIONS
MARK DATE DB DESCRIPTION
11.10.17 AM REV1
11.30.17 AM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
ALLEGION
ENGINEERING
11805 N. PENNSYLANNIA ST. - 1ST FLOOR
CARMEL, IN 46032
MMS/ACM MMS
2017.280
1ST FLOOR
0 2' 4' 8' 16' N
2
1
AREA NOT IN CONTRACT
AREA OF WORK
AREA NOT IN CONTRACT
AREA OF WORK
ELECTRICAL PLAN NOTES
ELECTRICAL PLAN
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER POLE FOR
ELECTRICAL AND DATA.
PROVIDE JUNCTION BOX
ABOVE CEILING.
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
ELECTRICAL LEGEND
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
ELECTRICAL PLAN/
A121
1
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
GENERAL RCP NOTES
CEILING PLAN NOTES
MECHANICAL NOTES
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
GENERAL ELEC. NOTES
PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE
FOR MORE DETAILS.
COORDINATE COPIER RECEPTACLE WITH TENANT AND FURNITURE
VENDOR. PROVIDE DEDICATED RECEPTACLE AS REQUIRED.
DESIGN INTENT IS FOR COPIER TO BE FED FROM WORKSTATIONS
FOR POWER AND DATA IF POSSIBLE.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
PROVIDE POWER AND DATA FOR POWER POLE. VERIFY ELECTRIC
REQUIREMENTS WITH TENANT PRIOR TO INSTALLING. POWER POLE
PROVIDED BY CONTRACTOR AND TO MATCH BUILDING
STANDARD POWER POLE STYLE AND COLOR.
PROVIDE POWER AND DATA AT 72" A.F.F. FOR TENANT'S WALL
MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH
TENANT. PROVIDE 1 1
4" CONDUIT IN WALL.
COORDINATE POWER REQUIREMENTS FOR TENANT PROVIDED
PLOTTER, PROVIDE DEDICATED POWER AS NEEDED.
PROVIDE WIRE MOLD ALONG EXTERIOR PERIMETER OF ROOM.
COORDINATE WITH TENANT FOR EXACT QUANTITY OF OUTLETS
WITH TENANT. COORDINATE EXACT LOCATION AND HEIGHT WITH
TENANT. WIRE MOLD TO HAVE POWER ONLY, NO DATA
REQUIRED.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS
FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO
ORDERING.
PROVIDE WIRE MOLD ALONG EXTERIOR WALL AT BACK OF WORK
SURFACE TO HOLD (4) POWER OUTLETS. COORDINATE EXACT
LOCATION AND HEIGHT WITH TENANT. WIRE MOLD TO HAVE
POWER ONLY, NO DATA REQUIRED.
COORDINATE WITH TENANT IF ADDITIONAL POWER IS REQUIRED IN
ELECTRICAL ROOM.
PROVIDE POWER FOR OWNER PROVIDED DISPLAY CASE.
COORDINATE REQUIREMENTS WITH OWNER.
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE
AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN
MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO
RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL
LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING
ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY
WITH THE INDIANA MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
CONTROL ID LAB LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION.
CONTROL FLEX SPACE LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION.
CONTROL TESTING LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION.
PROVIDE 2"H X 4"W DRYWALL BULKHEAD AND STRUCTURAL
SUPPORT IN CEILING AS REQUIRED TO SUPPORT HERCULITE DOOR
AND FRAMELESS GLASS SYSTEM.
COORDINATE EXACT LOCATION AND HEIGHT OF LINEAR PENDANT
WITH SDI PRIOR TO INSTALLATION.
0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION
OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES
UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO MATCH BUILDING
STANDARD.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS
TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE
TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL
ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING.
ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
5. ALL WIRELESS ACCESS PRODUCTS AND INSTALLATION TO BE COORDINATED BY ALLEGION.
J
J
B
O
J
+42"
1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2'x2' AT 8'-0" A.F.F. PROVIDE NEW CEILING
TILES THROUGHOUT TO MATCH BUILDING STANDARD: 2'x2'
ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND
REPLACE WITH NEW AS REQUIRED.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE
ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN
RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH
PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO
INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1
STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO
MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI.
4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE
OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE
BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR
RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI).
EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE.
5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO MATCH
BUILDING STANDARD. REPLACE WITH NEW AS REQUIRED.
WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO
ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE
SHOWN ADJACENT ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND
IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS
LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL
OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE
CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE
BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE
PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
7. PROVIDE ALTERNATE PRICE TO REPLACE ALL EXISTING
SWITCHES TO DIMMER SWITCH AND ALL NEW SWITCHING TO BE
DIMMABLE.
LIGHT CIRCUIT
EXIT LIGHT FIXTURE
DELETED
LIGHT FIXTURE, 2'x4',
MOBERN
MFPEL24LED50DMVWH40
LED EDGELIT FLAT
PANEL - CONTACT
PATRICK MCDOWELL
FOR INFORMATION
(317)697-1983
NEW OR RELOCATED EXISTING TO REMAIN
EXIT LIGHT FIXTURE
LIGHT CIRCUIT
LIGHT FIXTURE, 2'x2',
FLUORESCENT.
PARABOLIC
LIGHT FIXTURE, 2'x4',
FLUORESCENT,
PARABOLIC
LEGEND
RECESSED LIGHT FIXTURE,
INCANDESCENT
SWITCH, PROJECTOR
SCREEN
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
SWITCH, PROJECTOR
SCREEN
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
SWITCH, GARBAGE
DISPOSAL
SWITCH, GARBAGE
DISPOSAL
LIGHT FIXTURE, 2'x2',
GMAX LEDPANEL 40
4000K - CONTACT
PATRICK MCDOWELL
FOR INFORMATION
(317)697-1983
EXISTING/RELOCATED
DIFFUSER, LAY-IN, 4"x4'
EXISTING/RELOCATED
DIFFUSER, LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND
CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
FOR PROJECTS REQUIRING STATE DESIGN REVIEW, HVAC DIFFUSER
RELOCATIONS ARE TO BE REVIEWED/RELEASED AS PART OF THE
ARCHITECTURAL SCOPE OF WORK.
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER, LAY-IN, 4"x4'
DIFFUSER, LAY-IN, 2'x2'
GYPSUM BOARD
CEILING - PAINT
EXIST. GYPSUM BOARD
CEILING
WAC LIGHTING E=EM² -
MODEL: PD-457
dwelLED LED LINEAR
PENDANT, BRUSHED
ALUMINUM FINISH.
CONTACT PATRICK
MCDOWELL FOR
INFORMATION
(317)697-1983
LIGHT FIXTURE,
PENDANT
LIGHT FIXTURE, LED - VODE
ZIP TWO 707 -
PERPENDICULAR TO T-BAR
- CONTACT PATRICK
MCDOWELL FOR
INFORMATION
(317)697-1983
1
2
2
2
2
2
2
2
2
14'-3" 4'-0"
(CLEAR)
FE
(24 x 36 OPEN
WALL SPACE)
12" DEEP ADJUSTABLE
GLASS SHELVES (DOUG
MOCKETT SH14 SETS WITH
2X C-STYLETRACKS, 5 1
2"
BRACKETS)
3'-0"
5'-8"
EQ. EQ.
VINYL BASE
1'-4" 3'-0" 2'-0"
9" 1'-0" 3'-0"
ARCHITECTURAL
FLOOR PLAN
NOT TO SCALE A111
WALL AT MULLION DETAIL
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
STANDARD WALL
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING
W1
W2
WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
A111
1
DATE DESCRIPTION
ISSUE
10.11.17 REVIEW SET
10.13.17 PERMIT SET
11.09.17 BID SET
REVISIONS
MARK DATE DB DESCRIPTION
11.10.17 AM REV1
11.30.17 AM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
ALLEGION
ENGINEERING
11805 N. PENNSYLANNIA ST. - 1ST FLOOR
CARMEL, IN 46032
MMS/ACM MMS
2017.280
1ST FLOOR
0 2' 4' 8' 16' N
2
1
DEMOLITION PLAN
REMOVE EXISTING ENTRY DOOR AND ADJACENT EXTERIOR
GLAZING. COORDINATE WITH OWNER/MANUFACTURER FOR NEW
DOOR REQUIREMENTS NECESSARY FOR EXTERIOR APPLICATION.
REMOVE EXISTING WALL AS REQUIRED FOR NEW DOOR
INSTALLATION.
SALVAGE EXISTING FIRE EXTINGUISHER CABINET FOR
REINSTALLATION.
REMOVE EXISTING WALL CONSTRUCTION TO CORNER. REPAIR
EXISTING ADJACENT WALL CONSTRUCTION AS REQUIRED.
SALVAGE EXISTING LED LIGHT FIXTURE FOR RELOCATION. REFER
TO CEILING PLAN FOR FURTHER INFORMATION.
DEMOLITION PLAN NOTES
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE, TRACK
LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
DEMOLITION LEGEND
AREA NOT IN CONTRACT
AREA OF WORK
DEMOLITION PLAN/
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. CONFIRM THAT ALL EXISTING WALLS ARE FULLY INSULATED. IF
NOT, PROVIDE NEW INSULATION AS REQUIRED. PROVIDE 2' OF
INSULATION ABOVE CEILING ON EITHER SIDE OF WALL.
3. ALL WALLS RECEIVING PT2 OR DRY ERASE WALLCOVERING
(WC1) SHALL RECEIVE LEVEL 5 DRYWALL FINISH. REFER TO SHEET
A211 FOR LOCATIONS.
4. PROVIDE ALTERNATE COST TO EXTEND ALL WALLS
SURROUNDING OFFICES AND CONFERENCE ROOMS TO DECK.
GENERAL NOTES
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS. COORDINATE WITH TENANT ON
EXACT SINK REQUIREMENT AND SPECIFICATION.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
NOT USED.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10. IF FIRE EXTINGUISHER IS EXISTING,
CONTRACTOR TO ENSURE IT IS IN PROPER WORKING ORDER OR
PROVIDE NEW AS NEEDED. REUSE SALVAGED FIRE EXTINGUISHERS
FROM DEMOLITION IF POSSIBLE.
PROVIDE BLOCKING IN WALL OR BLACK MELAMINE BACKER
BOARD FOR TENANT PROVIDED FLAT SCREEN TV. CONFIRM WITH
TENANT ON EXACT LOCATION AND HEIGHT.
PROVIDE FRAMELESS SIDELITE WITH 4" SIDELITE STAINLESS STEEL TOP
AND BOTTOM RAIL SIMILAR TO D2. NOTE GLASS RUNS STRAIGHT
TO FLUSH WALL CORNER AND THERE IS NO 4" WING WALL.
PROVIDE BLOCKING AS REQUIRED FOR BARN DOOR ASSEMBLY.
REFER TO SHEET A211 FOR FURTHER INFORMATION.
PROVIDE BLOCKING AS REQUIRED FOR OWNER PROVIDED GLASS
MARKER BOARDS. CONFIRM INSTALLATION LOCATION WITH
OWNER.
SINGLE BASIN MOLDED PLASTIC UTILITY SINK. PROVIDE CUT SHEETS
TO OWNER FOR APPROVAL.
ARCHITECTURAL PLAN NOTES
0 2' 4' 8' 16'
TYP.
A111
1
1. REMOVE UPGRADED PROFILE CEILING TILE THROUGH HALLWAY. REFER
TO CEILING PLAN FOR FURTHER INFORMATION.
2. WHERE EXISTING LIGHT FIXTURE INTERSECTS WITH GRID, REPAIR GRID TO
"LIKE NEW CONDITION".
DEMOLITION GENERAL NOTES
0 1' 2' 4'
ELEVATION
A111
2
A111
2
1
109
STG.
104
JANITOR
105
MICRO
REFRIG
MICRO
6x5
6x5
6x5 6x5 6x5 6x5
6x5 6x5
6x5 6x5
6x5
6x5
6x5
6x5
6x5
6x5
6x5
6x5
6x5
6x5 6x5
6x5
6x5 6x5
6x5
6x5 6x5
6x5 6x5
6x5
6x5
5x3 5x3
6x5
6x5
5x3 5x3
x
MOTHERS
124
10'-0" 8'-0"
x
SPRINKLER
121
15'-1" 5'-0"
x
OFFICE
134
14'-10" 11'-7"
x
OFFICE
138
14'-10" 11'-11"
x
OFFICE
127
x 11'-7" 15'-6"
OFFICE
128
x 11'-7" 15'-6"
OFFICE
131
11'-7" 15'-6"
OPEN OFFICE
126
COPY
130
COPY
125
x
CONFERENCE
116
14'-0" 19'-5"
x
SHARED
OFFICE
123
13'-2" 19'-5"
x
HUDDLE
118
9'-9" 13'-4"
x
QUIET
ROOM
120
15'-1" 9'-11"
x
SERVER
122
13'-5" 11'-0"
x
SERVER
119
14'-4" 13'-4"
x
FOCUS
137
5'-8" 8'-0"
x
FOCUS
136
5'-11" 8'-0"
6x5
6x5
6x5
6x5 6x5
6x5
5x3
6x5 6x5
6x5 6x5 x
HUDDLE
114
6'-7" 11'-3"
VEND. VEND.
FE
FE
FE
EL
EL
x
VESTIBULE
100
25'-0" 10'-10"
x
BREAK
139
19'-7" 13'-2"
ELN
ELN
ELN
ELN
ELN
ELN
ELN
ELN ELN
ICE
x
OFFICE
107
11'-0" 11'-9"
x
OFFICE
109
11'-0" 11'-9"
ENTRY
101
DISPLAY
CASE
6x5
6x5
6x5
6x5
6x5
6x5
LF
ADVANCED
DEVE. AREA
102
TESTING
108
6x5 6x5
LF LF
LF
x
INDUSTRIAL DESIGN
MEETING AREA
104
18'-2" 11'-9"
x
ID LAB
105
14'-10" 11'-11"
x
FLEX
SPACE
106
14'-11" 22'-4"
LF LF
INDUSTRIAL
DESIGN AREA
103
567 SF
VF VF VF VF
6x5
LF
LF
6x5
6x5
6x5
x
CONFERENCE
141
18'-1" 12'-1"
FE
ELN
ELN
ELN
ELN
ELN
6x5
6x5
LF LF
LF
LF
LF
LF
LF
LF
LF
4x3
6x5
6x5
6x5
6x5
6x5
6x5
LF LF LF LF
FE
LIFE SAFETY
LIFE SAFETY PLAN L100
DATE DESCRIPTION
ISSUE
10.11.17 REVIEW SET
10.13.17 PERMIT SET
11.09.17 BID SET
REVISIONS
MARK DATE DB DESCRIPTION
11.10.17 AM REV1
11.30.17 AM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
ALLEGION
ENGINEERING
11805 N. PENNSYLANNIA ST. - 1ST FLOOR
CARMEL, IN 46032
MMS/ACM MMS
2017.280
1ST FLOOR
N
2
1
0 4' 8' 16'
AREA NOT IN CONTRACT
AREA OF WORK
LIFE SAFETY NOTES GENERAL NOTES
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
20,024 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 47
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE A121)
BUILT BEFORE 1978? NO
4,626
4,626
20,024 1 20,024
47
BUILDING CONSTRUCTION TYPE II-B
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN - MATCH BUILDING STANDARD
FE
EMERGENCY LIGHT - MATCH BUILDING STANDARD
FE
TRAVEL DISTANCE
NUMBER OF EXITS REQUIRED: 1 PROVIDED: 4
EP
EX
EX
EX
BUSINESS
TRAVEL DISTANCE = 145'
EX
EP
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST
COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE
ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE
OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE
OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD.
4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE
PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS
REQUIRED BY CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR
OTHER CONFLICTS.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER
AND DATA OUTLETS AS REQUIRED.
9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO
BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND
PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCH
EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
PURCHASE.
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.
REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE
TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM
WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE
FOR WIRING THE BASE PANELS OF THE WORKSTATIONS.
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL
CONDUITS TO JUNCTION BOXES.
14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN
EXISTING SPACES. CONSULT WITH LANDLORD.
15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.
16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.
REQUIREMENTS.
17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVER PLATE.
18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.
19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS
OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION.
FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR
EXPENSE.
21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS
(I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS).
MECHANICAL &
ELECTRICAL NOTES
1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA
BUILDING CODE FOR CLASS A FIRE RATINGS.
2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM
ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS,
CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR
NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS
3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF
ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING
AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR
TO PURCHASING NEW.
4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH
COATS.
5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET).
6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE
NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK.
PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING
OWNER.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.
8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO
MATCH ADJACENT WALL FINISH.
9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT
DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL
MILLWORK.
10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH
INFORMATION.
11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
FINISH NOTES
1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
PROVIDED UNDER THE GENERAL CONTRACT.
2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
(A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING
SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION
DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
CONTRACTOR.
6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.
BACKSPLASHES TO BE FIELD APPLIED.
7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC
LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED
OTHERWISE.
8. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS
(CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY).
9. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
MILL/CASEWORK NOTES
1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO
DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS.
2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR
OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT
MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE
CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR
AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING
THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE
ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF
WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS.
4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE
BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN
THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING
AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY
OWNER.
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN.
VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION.
6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES TO REMAIN.
7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.
SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.
8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID
INSTRUCTIONS.
9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO
REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION
EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE
CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY
SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE
BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE
OWNER'S USE IN THE PROJECT.
10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION)
REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING
BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES,
AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES.
REFER TO SECTION 300.21.
11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL
TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN
"AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS.
12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
DEMOLITION NOTES
VICINITY MAP
NOT TO SCALE NOT TO SCALE
KEY PLAN - 1ST FLOOR
1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE .
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND
LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE
CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.
3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS
OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR
WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS
OF THE SCOPE OF WORK.
4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS
PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS.
NOTED DIMENSIONS TAKE PRECEDENCE.
5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY
DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC.
6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL
ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS
STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,
AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE
CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN
ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.
7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING
HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING
HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND
WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS
OF ADJACENT TENANTS.
8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL
COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE
OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER
FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR
DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE
CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.
9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH
APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY
SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.
10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND
SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,
SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR
MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.
11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO
CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR
STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING
CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES
SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED
BY CONSTRUCTION CREWS.
13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF
DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST
PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6
MIL VAPOR BARRIER ON EACH SIDE.
14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED
BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF
THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING
MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS
INDICATED ON THE CEILING PLAN).
15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY,
PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT
OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE.
16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS
INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR
APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO
DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT
INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.
18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT
TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF
MATERIALS AND EQUIPMENT.
19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY
STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH
ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL,
MECHANICAL, AND ELECTRICAL CONSTRUCTION.
20. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY
SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.
21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER
TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY
CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER
DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING
MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT
ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED
AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED.
23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING
WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION
JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS.
24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH
DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE
FOR FINISH.
25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.
26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE
CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT
REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL
CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK.
27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR
INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT.
28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM
BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE
DRAWINGS. WRITTEN DIMENSIONS GOVERN.
29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS.
REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING
STANDARD.
30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS
REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND
SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT
DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL
CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR
AGREEMENT.
31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH
APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED
PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE
DAMPERED IF REQUIRED.
33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN
INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON L100 IS BASED UPON AVAILABLE
INFORMATION AND FIELD VERIFICATION.
34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND
WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW
CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED.
1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN,
INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE
SPRINKLER SYSTEM.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE,
THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND
REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE
SUPPRESSION SYSTEMS.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND
SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
FIRE PROTECTION NOTES
N
T111 COVER SHEET AND GENERAL PROJECT NOTES
L100 LIFE SAFETY PLAN
A111 DEMOLITION PLAN & ARCHITECTURAL FLOOR PLAN
A121 REFLECTED CEILING PLAN: HVAC / LIGHTING / ELECTRICAL PLAN
A211 DOOR SCHEDULE / INTERIOR DETAILS / FINISH PLAN
INDEX OF DRAWINGS
= AREA
OF WORK