HomeMy WebLinkAboutFCC - SMITH_CONSTRUCTION SET 12_15_17+ 11'-0-5/8"
LEVEL TWO
+ 0'-0"
LEVEL ONE
12
9
9 : 12 PITCH
5 : 12 PITCH
EXISTING BLOCK
BASE TO REMAIN
EXISTING BLOCK
BASE TO REMAIN
NEW 12"
WOOD COLUMNS
NEW 12"
WOOD COLUMNS
NEW 12"
WOOD COLUMNS
NEW 12"
WOOD COLUMNS
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
EXIST
FOUNDATION
SHINGLE ROOF
SHINGLE ROOF
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
NOTE:
INSTALL FLASHING AT TOP
OF 1 x TRIM AS REQ'D
ALL ROOFS TO
ALIGN WITH RIDGE
+ 11'-0-5/8"
LEVEL TWO
+ 0'-0"
LEVEL ONE
12
5
12
5
12
12 9
9
EXISTING BLOCK
BASE TO REMAIN
NEW 12"
WOOD COLUMNS
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
REMOVE DOOR AND PREP
FOR NEW WINDOW
REMOVE WINDOW AND
PREP FOR NEW WINDOW
REMOVE UPPER CONC
REMOVE UPPER CONC BLOCK FROM COLUMN
BLOCK FROM COLUMN
REMOVE EXIST WOOD
COLUMN - PREP FOR NEW
REMOVE EXIST WOOD
COLUMN - PREP FOR NEW
REMOVE WINDOW
REMOVE WINDOW
REMOVE WINDOWS
CUT WALL FOR NEW
WINDOW
CUT WALL FOR NEW
WINDOW
REMOVE EXIST PLUMBING
- PREP FOR NEW
EXISTING SUB-FLOOR TO
REMAIN
EXISTING SUB-FLOOR TO
REMAIN
EXISTING SUB-FLOOR TO
REMAIN
REMOVE EXIST CHIMNEY
REMOVE EXIST BEARING
WALL - INSTALL NEW LAM
BEAM ON CENTERLINE
FOR LEVEL TWO JOISTS
REMOVE EXIST BEARING
WALL - INSTALL NEW LAM
BEAM ON CENTERLINE
FOR LEVEL TWO JOISTS
REMOVE EXIST STAIRS -
PREP FOR NEW
REMOVE WINDOW AND
PREP FOR NEW WINDOW
NOTE:
REMOVE EXIST LEVEL TWO
FLOOR JOISTS AND ENTIRE
ROOF STRUCTURE
4'-0" 36'-8 1/4"
24'-4 1/4"
9'-0" 15'-4 1/4"
5'-4 1/2" 3'-7 1/2" 3'-3 1/2" 6'-11" 5'-1 3/4"
18'-5" 10'-3" 1'-1 1/4" 10'-11"
25'-3 1/4"
4'-2 3/8" 7'-4 1/8" 13'-8 3/4"
5'-11 1/2" 12'-5 1/2" 5'-1 1/2" 5'-1 1/2" 6'-3 1/2" 4'-7 1/2"
26'-0 1/4" 4'-0" 5'-2"
19'-2 3/8" 17'-5 7/8"
7'-5 3/4" 5'-6" 4'-0" 6'-6"
12'-9" 8'-6"
2'-1" 5'-11 1/2"
1'-0 1/2" 7'-2" 2'-5 1/2"
2'-1 1/2" 10'-9 1/2"
2'-1 3/4" 1'-10 1/4"
12'-4 1/4"
RAFTER BEARING
FINISH FLOOR
JOIST BEARING
EXITING FLOOR
0'-0"
+10'-0"
+11'-0-5/8"
+20'-1-3/4"
10'-0" 1'-0 5/8" 9'-1 1/8"
ATTIC
ATTIC ATTIC
GREAT ROOM
LANDING
DINING ROOM
12
9
12
9
EXTEND WALL TO
10'-0" HIGH - SIMPSON
ATTACHMENT
ANCHOR
DROPPED LAM BEAM
IN BULKHEAD
DROPPED LAM BEAM
IN BULKHEAD
FRONT PORCH
NEW LAM BEAM
EXIST BLOCK BASE
TO REMAIN
REMOVE BLOCK
INSTALL 12"
WOOD COLUMN
RAFTER BEARING
+13'-0-5/8"
2'-0"
5'-0"
RAFTER BEARING
+10'-8-3/8"
BRACE KNEE WALL
AS REQ'D
6'-2 1/4"
1
3
RAFTER BEARING
FINISH FLOOR
JOIST BEARING
EXITING FLOOR
0'-0"
+10'-0"
+11'-0-5/8"
+20'-1-3/4"
ATTIC
ATTIC MASTER BEDROOM MASTER CLOSET LAUNDRY HALL BEDROOM
FRONT PORCH GREAT ROOM
LANDING
KITCHEN MUD ROOM
CATHEDRAL CEILING
12
9
REMOVE DOOR AND PREP
FOR NEW WINDOW
REMOVE WINDOW AND
PREP FOR NEW WINDOW
REMOVE UPPER CONC
REMOVE UPPER CONC BLOCK FROM COLUMN
BLOCK FROM COLUMN
REMOVE EXIST WOOD
COLUMN - PREP FOR NEW
REMOVE EXIST WOOD
COLUMN - PREP FOR NEW
REMOVE WINDOW
REMOVE WINDOW
REMOVE WINDOWS
CUT WALL FOR NEW
WINDOW
CUT WALL FOR NEW
WINDOW
REMOVE EXIST PLUMBING
- PREP FOR NEW
EXISTING SUB-FLOOR TO
REMAIN
EXISTING SUB-FLOOR TO
REMAIN
EXISTING SUB-FLOOR TO
REMAIN
REMOVE EXIST CHIMNEY
REMOVE EXIST BEARING
WALL - INSTALL NEW LAM
BEAM ON CENTERLINE
FOR LEVEL TWO JOISTS
REMOVE EXIST BEARING
WALL - INSTALL NEW LAM
BEAM ON CENTERLINE
FOR LEVEL TWO JOISTS
REMOVE EXIST STAIRS -
PREP FOR NEW
REMOVE WINDOW AND
PREP FOR NEW WINDOW
NOTE:
REMOVE EXIST LEVEL TWO
FLOOR JOISTS AND ENTIRE
ROOF STRUCTURE
F
R R R
R R R
S S S
R
R
R
S
R R R
R R R
R
GFI
SS
S
SS
R R
R R
S
GFI
GFI
R R R
SSSS
S
TO LEVEL
TWO
TO
BASEMENT
S SS
S
WP
WP
S
GFI
GFI
R R
R
GFI
F
F
R R R
SS
TO LEVEL
ONE
S
S
S S
S
SS
SS
S
S
S
S3
S
220 OUTLET
WP DUPLEX WATER PROOF
DUPLEX ABOVE FINISH FLOOR
DUPLEX GROUND FAULT
SINGLE POLE SWITCH
3-WAY SWITCH
SURFACE MOUNTED FIXTURE
SUSPENDED FIXTURE
PENDANT FIXTURE
RECESSED CAN
RECESSED CAN WATERPROOF
COMBINATION FAN / LIGHT
STANDARD DUPLEX OUTLET
+36"
WALL SCONCE
GFI
P
R
WP
S
L
CEILING FAN / LIGHT
ELECTRICAL LEGEND
SMOKE DETECTOR
DUAL HEAD EXT. FLOOD
F
F L RECESSED FAN / LIGHT CAN
F EXHAUST FAN
R RECESSED DIRECTIONAL
WALL MOUNTED STRIP FLUORESCENT
UNDER CABINET LIGHT
4
ELECTRICAL
PLANS
ALL IDEAS, DESIGNS AND PLANS INDICATED OR
REPRESENTED BY THESE DRAWINGS ARE OWNED
BY, AND THE PROPERTY OF STUART R SHADE, RA.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS
RESERVED, EXCEPT FOR USES EXPRESSLY
PERMITTED IN WRITING.
SHEET NUMBER:
DATE:
CERTIFICATION:
SRS ARCHITECTS
13245 ALLISONVILLE RD
FISHERS, INDIANA 46038
PHONE: 317-989-6248
E-MAIL : stushade@att.net
15 SEPTEMBER, 2016
REV 1:
T
A
N
N
I
A
R
A
T
U
S
A
E
R
I
G
T
S
R
T
R.
H
S
STATE OF
E
E
D
D
E
R
E
A
I
D
I
T
C
H
C
AR00034184
PROJECT :
GREENFIELD , INDIANA
PRIVATE RESIDENCE
REVIEW SET 12_8_17
BUILDER :
13590 - NORTH MERIDIAN ST
FCC DEVELOPMENT
SUITE 100
CARMEL , INDIANA 46032
SCALE:
1
1/4"=1'-0"
LEVEL ONE ELECTRICAL
SCALE:
2
1/4"=1'-0"
LEVEL TWO ELECTRICAL
12
5
12
LINE OF ROOF 5
BEYOND
LINE OF SLOPED
CEILING BEYOND
LINE OF ROOF
BEYOND
LINE OF SLOPED
CEILING BEYOND
STAIRS BEHIND WALL
10"
7 3/4"
DROPPED LAM BEAM
IN BULKHEAD
DROPPED LAM BEAM
IN BULKHEAD EXTEND WALL TO
10'-0" HIGH - SIMPSON
ATTACHMENT
ANCHOR
NEW LAM BEAM
EXIST BLOCK BASE
TO REMAIN
REMOVE BLOCK
INSTALL 12"
WOOD COLUMN
RAFTER BEARING
+10'-8-3/8"
10'-0" 1'-0 5/8" 9'-1 1/8"
2
3
3
3
2'-0"
1'-0"
12'-0"
FLASHING
1 x 10 COMP TRIM
MTL DRIP EDGE
CONT. GUTTER
1 x 6 COMP TRIM
COMP SOFFIT W/
AREA VENTS
1 x 8 COMP TRIM
SHINGLE ROOF
7/16" OSB SHEATHING
2 x RAFTERS @ 16" CC
DORMER BEYOND
3/4" T & G SHEATHING
ENGINEERED FLOOR
SYSTEM - INSUL WHERE
REQUIRED
1/2" GYP CEILING
NOTE:
EXTEND EXIST WALL TO
10'-0" ABOVE FLOOR -
SECURE WITH SIMPSON
WALL TIES OR EXTEND
NEW STUDS BELOW EXIST
PLATE
INSULATION
NEW COMP LAP SIDE
REPLACE SHEATHING AS
REQUIRED
EXISTING FLOOR
12'-0"
FLASHING
1 x 10 COMP TRIM
1/2" GYP CEILING
NOTE:
EXTEND EXIST WALL TO
10'-0" ABOVE FLOOR -
SECURE WITH SIMPSON
WALL TIES OR EXTEND
NEW STUDS BELOW EXIST
PLATE
INSULATION
NEW COMP LAP SIDE
REPLACE SHEATHING AS
REQUIRED
EXISTING FLOOR
1'-0"
MTL DRIP EDGE
CONT. GUTTER
1 x 6 COMP TRIM
COMP SOFFIT
1 x 8 COMP TRIM
1'-0"
MTL DRIP EDGE
CONT. GUTTER
1 x 6 COMP TRIM
COMP SOFFIT W/
AREA VENTS
1 x 8 COMP TRIM
SHINGLE ROOF
7/16" OSB SHEATHING
2 x RAFTERS @ 16" CC
AIR BAFFLE
SHINGLE ROOF
7/16" OSB SHEATHING
2 x RAFTERS @ 16" CC
1 x 6 COMP TRIM
MTL FLASHING
LAP COMP SIDING
OVER 7/16" OSB
1/2" GYP
CLG JOISTS W/ R-38 BATT
1/2" GYP OVER 2 x 4'S @
16" CC W/ R-13 BATT INSUL
ROOF BEYOND
3/4" T & G SHEATHING
OVER ENGINEERED JOISTS
2'-0"
SHINGLE ROOF
7/16" OSB SHEATHING
2 x RAFTERS @ 16" CC
1'-5"
MTL DRIP EDGE
CONT. GUTTER
1 x 6 COMP TRIM
COMP SOFFIT W/
AREA VENTS
1 x 10 COMP TRIM
10'-8 3/8"
1'-2"
1 x 10 TRIM
COMP SOFFIT
LAM BEAM
3/4" T & G SHEATHING
OVER ENGINEERED JOISTS
BEAR RAFTERS BETWEEN
FLOOR JOISTS
3
CROSS SECTIONS
WALL SECTIONS
ALL IDEAS, DESIGNS AND PLANS INDICATED OR
REPRESENTED BY THESE DRAWINGS ARE OWNED
BY, AND THE PROPERTY OF STUART R SHADE, RA.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS
RESERVED, EXCEPT FOR USES EXPRESSLY
PERMITTED IN WRITING.
SHEET NUMBER:
DATE:
CERTIFICATION:
SRS ARCHITECTS
13245 ALLISONVILLE RD
FISHERS, INDIANA 46038
PHONE: 317-989-6248
E-MAIL : stushade@att.net
15 SEPTEMBER, 2016
REV 1:
T
A
N
N
I
A
R
A
T
U
S
A
E
R
I
G
T
S
R
T
R.
H
S
STATE OF
E
E
D
D
E
R
E
A
I
D
I
T
C
H
C
AR00034184
PROJECT :
GREENFIELD , INDIANA
PRIVATE RESIDENCE
REVIEW SET 12_8_17
BUILDER :
13590 - NORTH MERIDIAN ST
FCC DEVELOPMENT
SUITE 100
CARMEL , INDIANA 46032
SCALE:
WALL SECTION
1/2"=1'-0"
2
SCALE:
CROSS SECTION
1/4"=1'-0"
A-A
SCALE:
CROSS SECTION
1/4"=1'-0"
SCALE: B-B
WALL SECTION
1/2"=1'-0"
1
SCALE:
WALL SECTION
1/2"=1'-0"
3
LIVING ROOM
CEILING HGT.
10'-0"
WDH 210510
DINING ROOM
CEILING HGT.
10'-0"
12'-1 5/8" 2'-1 1/8" 11'-9 1/2"
KITCHEN
CEILING HGT.
10'-0"
OFFICE
CEILING HGT.
10'-0"
MUD ROOM
CEILING HGT.
10'-0" HALL
CL
POWDER
CEILING HGT.
10'-0"
PANTRY
CEILING HGT.
10'-0"
3/0 x 6/8 BARN
3/0 x 6/8
2/0 x 6/8
2/4 x 6/8
2/4 x 6/8
2/6 x 6/8
2/4 x 6/8
3/0 x 8/0
3'-8" 6'-5 1/2" 8'-2 3/4"
2'-1 1/2" 3'-0" 1'-1 1/2"
WDH 210410
WDH 210410
WDH 210510
WDH 210510
WDH 210510
WDH 20310
(3) WDH 2454
REMOVE AND
INSTALL NEW
WINDOW
NEW WINDOW IN
EXIST WALL
THICKEN WALL TO
RECEIVE DUCT
WORK
NEW LAM BEAM ON OLD
WALL CENTERLINE
NOTE:
FLOOR PROVIDER TO
DESIGN FOR LEVEL TWO
WALLS ABOVE
2'-0"
NOTE:
SET ADDITION ON EXIST
CONC SLAB - FLASH BASE
AS REQUIRED
NOTES:
· FINISHED AREA - 962 SQ FT
· WINDOW NUMBERS PER
ANDERSEN 400 SERIES
BED ROOM 2
CEILING HGT.
9'-0"
8'-7 3/4" 7'-6" 5'-0" 2'-0" 11'-8 1/2"
10'-6" 10'-6"
12'-1 3/4" 6'-0 1/2" 2'-11 1/2" 3'-4" 2'-3 1/2"
3'-0" 2'-5 1/8" 12'-0" 5'-10 1/8"
24'-4 1/4"
5'-10 1/8" 6'-4" 6'-4" 5'-10 1/8"
21'-10 1/2" 1'-6"
5'-6 1/2" 10'-9 1/2" 5'-6 1/2"
3'-6" 31'-0 3/4" 5'-7 1/2"
7'-4 3/8" 5'-7 7/8" 13'-4" 4'-8 1/2"
3'-6" 19'-6 1/2" 6'-9 3/4" 4'-8 1/2" 5'-7 1/2"
2'-0"
6'-9" 5'-6 1/2" 2'-0" 8'-6"
4'-6" 2'-8 1/2"
3'-4" 6'-0 3/4" 4'-0" 6'-0"
10'-3 1/2"
11" 11 3/4"
5'-6"
BED ROOM 3
CEILING HGT.
9'-0"
MASTER BEDROOM
CEILING HGT.
9'-0" TO CATHEDRAL
2/4 x 6/8
2/6 x 6/8
2/6 x 6/8
2/6 x 6/8
6/0 x 6/8 6/0 x 6/8
2/4 x 6/8
5/6 x 6/8 FOLD 2/0 x 6/8
FOLD
BATH
BATH
LAUNDRY
CLOSET
CLOSET CLOSET
LANDING
3'-0" 10'-10" 7'-9 1/4"
SLOPED
SLOPED
SLOPED
SLOPED
FLAT
FLAT
NOTES:
· FINISHED AREA - 874 SQ FT
· WINDOW NUMBERS PER
ANDERSEN 400 SERIES
WDH 2852 EGRESS
WDH 2042
WDH 2852 EGRESS WDH 2852 EGRESS
WDH 2852 EGRESS
WDH 210310
WDH 210310
(3) WTR 2831
LAM BEAM LAM BEAM
AREA OF SLOPED
CEILING
AREA OF SLOPED
CEILING
2 x 6 WALL
2'-4" 2'-2"
REMOVE DOOR AND PREP
FOR NEW WINDOW
REMOVE WINDOW AND
PREP FOR NEW WINDOW
REMOVE UPPER CONC
REMOVE UPPER CONC BLOCK FROM COLUMN
BLOCK FROM COLUMN
REMOVE EXIST WOOD
COLUMN - PREP FOR NEW
REMOVE EXIST WOOD
COLUMN - PREP FOR NEW
REMOVE WINDOW
REMOVE WINDOW
REMOVE WINDOWS
CUT WALL FOR NEW
WINDOW
CUT WALL FOR NEW
WINDOW
REMOVE EXIST PLUMBING
- PREP FOR NEW
EXISTING SUB-FLOOR TO
REMAIN
EXISTING SUB-FLOOR TO
REMAIN
EXISTING SUB-FLOOR TO
REMAIN
REMOVE EXIST CHIMNEY
REMOVE EXIST BEARING
WALL - INSTALL NEW LAM
BEAM ON CENTERLINE
FOR LEVEL TWO JOISTS
REMOVE EXIST BEARING
WALL - INSTALL NEW LAM
BEAM ON CENTERLINE
FOR LEVEL TWO JOISTS
REMOVE EXIST STAIRS -
PREP FOR NEW
REMOVE WINDOW AND
PREP FOR NEW WINDOW
NOTE:
REMOVE EXIST LEVEL TWO
FLOOR JOISTS AND ENTIRE
ROOF STRUCTURE
2
DEMOLITION
FLOOR PLANS
SCALE:
D
1/4"=1'-0"
DEMO PLAN
ALL IDEAS, DESIGNS AND PLANS INDICATED OR
REPRESENTED BY THESE DRAWINGS ARE OWNED
BY, AND THE PROPERTY OF STUART R SHADE, RA.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS
RESERVED, EXCEPT FOR USES EXPRESSLY
PERMITTED IN WRITING.
SHEET NUMBER:
DATE:
CERTIFICATION:
SRS ARCHITECTS
13245 ALLISONVILLE RD
FISHERS, INDIANA 46038
PHONE: 317-989-6248
E-MAIL : stushade@att.net
15 SEPTEMBER, 2016
REV 1:
T
A
N
N
I
A
R
A
T
U
S
A
E
R
I
G
T
S
R
T
R.
H
S
STATE OF
E
E
D
D
E
R
E
A
I
D
I
T
C
H
C
AR00034184
PROJECT :
GREENFIELD , INDIANA
PRIVATE RESIDENCE
REVIEW SET 12_8_17
BUILDER :
13590 - NORTH MERIDIAN ST
FCC DEVELOPMENT
SUITE 100
CARMEL , INDIANA 46032
SCALE:
1
1/4"=1'-0"
LEVEL ONE
SCALE:
2
1/4"=1'-0"
LEVEL TWO
COMPOSITE
LAP SIDING
EXIST
FOUNDATION
NEW WOOD DECK
RAILINGS REQ'D OVER 18"
ABOVE GRADE
8'-10 3/4"
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
1 x 10 BASE TRIM
NOTE:
INSTALL FLASHING AT TOP
OF 1 x TRIM AS REQ'D
ALL ROOFS TO
ALIGN WITH RIDGE
+ 11'-0-5/8"
LEVEL TWO
+ 0'-0"
LEVEL ONE
12
5
12
5
12
12 9
9
9 : 12 PITCH
EXISTING BLOCK
BASE TO REMAIN
NEW 12"
WOOD COLUMNS
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
EXIST
FOUNDATION
NEW WOOD DECK
RAILINGS REQ'D OVER 18"
ABOVE GRADE
SHINGLE ROOF
8'-10 3/4"
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
1 x 10 BASE TRIM 1 x 12 BASE TRIM 1 x 10 BASE TRIM
NOTE:
INSTALL FLASHING AT TOP
OF 1 x TRIM AS REQ'D
ALL ROOFS TO
ALIGN WITH RIDGE
12
9
9 : 12 PITCH
5 : 12 PITCH
COMPOSITE
LAP SIDING
COMPOSITE
LAP SIDING
EXIST
FOUNDATION
NEW WOOD DECK
RAILINGS REQ'D OVER 18"
ABOVE GRADE
SHINGLE ROOF
SHINGLE ROOF
1 x 6 WINDOW
TRIM
1 x 6 WINDOW
TRIM
1 x 10 BASE TRIM
NOTE:
INSTALL FLASHING AT TOP
OF 1 x TRIM AS REQ'D
ALL ROOFS TO
ALIGN WITH RIDGE
RIDGE W/ VENT
LAM BEAM
5/12 SHED DORMER
5/12 SHED DORMER
INCREASED
OVERHANG
DETAIL PRIOR TO CONSTRUCTION
9/12 PITCH ROOF
9/12 PITCH ROOF
9/12 PITCH ROOF
9/12 PITCH ROOF
CATHEDRAL CEILING BELOW
1
EXTERIOR
ELEVATIONS
SCALE:
R
1/4"=1'-0"
ROOF PLAN
ALL IDEAS, DESIGNS AND PLANS INDICATED OR
REPRESENTED BY THESE DRAWINGS ARE OWNED
BY, AND THE PROPERTY OF STUART R SHADE, RA.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS
RESERVED, EXCEPT FOR USES EXPRESSLY
PERMITTED IN WRITING.
SHEET NUMBER:
DATE:
CERTIFICATION:
SRS ARCHITECTS
13245 ALLISONVILLE RD
FISHERS, INDIANA 46038
PHONE: 317-989-6248
E-MAIL : stushade@att.net
15 SEPTEMBER, 2016
REV 1:
T
A
N
N
I
A
R
A
T
U
S
A
E
R
I
G
T
S
R
T
R.
H
S
STATE OF
E
E
D
D
E
R
E
A
I
D
I
T
C
H
C
AR00034184
PROJECT :
GREENFIELD , INDIANA
PRIVATE RESIDENCE
REVIEW SET 12_8_17
BUILDER :
13590 - NORTH MERIDIAN ST
FCC DEVELOPMENT
SUITE 100
CARMEL , INDIANA 46032
SCALE:
N
1/4"=1'-0"
NORTH ELEVATION
SCALE:
E
1/4"=1'-0"
EAST ELEVATION
SCALE:
S
1/4"=1'-0"
SOUTH ELEVATION
SCALE:
W
1/4"=1'-0"
WEST ELEVATION