HomeMy WebLinkAboutFCC - SMITH_CONSTRUCTION SET 12_15_17+ 11'-0-5/8" LEVEL TWO + 0'-0" LEVEL ONE 12 9 9 : 12 PITCH 5 : 12 PITCH EXISTING BLOCK BASE TO REMAIN EXISTING BLOCK BASE TO REMAIN NEW 12" WOOD COLUMNS NEW 12" WOOD COLUMNS NEW 12" WOOD COLUMNS NEW 12" WOOD COLUMNS COMPOSITE LAP SIDING COMPOSITE LAP SIDING COMPOSITE LAP SIDING EXIST FOUNDATION SHINGLE ROOF SHINGLE ROOF 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM NOTE: INSTALL FLASHING AT TOP OF 1 x TRIM AS REQ'D ALL ROOFS TO ALIGN WITH RIDGE + 11'-0-5/8" LEVEL TWO + 0'-0" LEVEL ONE 12 5 12 5 12 12 9 9 EXISTING BLOCK BASE TO REMAIN NEW 12" WOOD COLUMNS COMPOSITE LAP SIDING COMPOSITE LAP SIDING COMPOSITE LAP SIDING REMOVE DOOR AND PREP FOR NEW WINDOW REMOVE WINDOW AND PREP FOR NEW WINDOW REMOVE UPPER CONC REMOVE UPPER CONC BLOCK FROM COLUMN BLOCK FROM COLUMN REMOVE EXIST WOOD COLUMN - PREP FOR NEW REMOVE EXIST WOOD COLUMN - PREP FOR NEW REMOVE WINDOW REMOVE WINDOW REMOVE WINDOWS CUT WALL FOR NEW WINDOW CUT WALL FOR NEW WINDOW REMOVE EXIST PLUMBING - PREP FOR NEW EXISTING SUB-FLOOR TO REMAIN EXISTING SUB-FLOOR TO REMAIN EXISTING SUB-FLOOR TO REMAIN REMOVE EXIST CHIMNEY REMOVE EXIST BEARING WALL - INSTALL NEW LAM BEAM ON CENTERLINE FOR LEVEL TWO JOISTS REMOVE EXIST BEARING WALL - INSTALL NEW LAM BEAM ON CENTERLINE FOR LEVEL TWO JOISTS REMOVE EXIST STAIRS - PREP FOR NEW REMOVE WINDOW AND PREP FOR NEW WINDOW NOTE: REMOVE EXIST LEVEL TWO FLOOR JOISTS AND ENTIRE ROOF STRUCTURE 4'-0" 36'-8 1/4" 24'-4 1/4" 9'-0" 15'-4 1/4" 5'-4 1/2" 3'-7 1/2" 3'-3 1/2" 6'-11" 5'-1 3/4" 18'-5" 10'-3" 1'-1 1/4" 10'-11" 25'-3 1/4" 4'-2 3/8" 7'-4 1/8" 13'-8 3/4" 5'-11 1/2" 12'-5 1/2" 5'-1 1/2" 5'-1 1/2" 6'-3 1/2" 4'-7 1/2" 26'-0 1/4" 4'-0" 5'-2" 19'-2 3/8" 17'-5 7/8" 7'-5 3/4" 5'-6" 4'-0" 6'-6" 12'-9" 8'-6" 2'-1" 5'-11 1/2" 1'-0 1/2" 7'-2" 2'-5 1/2" 2'-1 1/2" 10'-9 1/2" 2'-1 3/4" 1'-10 1/4" 12'-4 1/4" RAFTER BEARING FINISH FLOOR JOIST BEARING EXITING FLOOR 0'-0" +10'-0" +11'-0-5/8" +20'-1-3/4" 10'-0" 1'-0 5/8" 9'-1 1/8" ATTIC ATTIC ATTIC GREAT ROOM LANDING DINING ROOM 12 9 12 9 EXTEND WALL TO 10'-0" HIGH - SIMPSON ATTACHMENT ANCHOR DROPPED LAM BEAM IN BULKHEAD DROPPED LAM BEAM IN BULKHEAD FRONT PORCH NEW LAM BEAM EXIST BLOCK BASE TO REMAIN REMOVE BLOCK INSTALL 12" WOOD COLUMN RAFTER BEARING +13'-0-5/8" 2'-0" 5'-0" RAFTER BEARING +10'-8-3/8" BRACE KNEE WALL AS REQ'D 6'-2 1/4" 1 3 RAFTER BEARING FINISH FLOOR JOIST BEARING EXITING FLOOR 0'-0" +10'-0" +11'-0-5/8" +20'-1-3/4" ATTIC ATTIC MASTER BEDROOM MASTER CLOSET LAUNDRY HALL BEDROOM FRONT PORCH GREAT ROOM LANDING KITCHEN MUD ROOM CATHEDRAL CEILING 12 9 REMOVE DOOR AND PREP FOR NEW WINDOW REMOVE WINDOW AND PREP FOR NEW WINDOW REMOVE UPPER CONC REMOVE UPPER CONC BLOCK FROM COLUMN BLOCK FROM COLUMN REMOVE EXIST WOOD COLUMN - PREP FOR NEW REMOVE EXIST WOOD COLUMN - PREP FOR NEW REMOVE WINDOW REMOVE WINDOW REMOVE WINDOWS CUT WALL FOR NEW WINDOW CUT WALL FOR NEW WINDOW REMOVE EXIST PLUMBING - PREP FOR NEW EXISTING SUB-FLOOR TO REMAIN EXISTING SUB-FLOOR TO REMAIN EXISTING SUB-FLOOR TO REMAIN REMOVE EXIST CHIMNEY REMOVE EXIST BEARING WALL - INSTALL NEW LAM BEAM ON CENTERLINE FOR LEVEL TWO JOISTS REMOVE EXIST BEARING WALL - INSTALL NEW LAM BEAM ON CENTERLINE FOR LEVEL TWO JOISTS REMOVE EXIST STAIRS - PREP FOR NEW REMOVE WINDOW AND PREP FOR NEW WINDOW NOTE: REMOVE EXIST LEVEL TWO FLOOR JOISTS AND ENTIRE ROOF STRUCTURE F R R R R R R S S S R R R S R R R R R R R GFI SS S SS R R R R S GFI GFI R R R SSSS S TO LEVEL TWO TO BASEMENT S SS S WP WP S GFI GFI R R R GFI F F R R R SS TO LEVEL ONE S S S S S SS SS S S S S3 S 220 OUTLET WP DUPLEX WATER PROOF DUPLEX ABOVE FINISH FLOOR DUPLEX GROUND FAULT SINGLE POLE SWITCH 3-WAY SWITCH SURFACE MOUNTED FIXTURE SUSPENDED FIXTURE PENDANT FIXTURE RECESSED CAN RECESSED CAN WATERPROOF COMBINATION FAN / LIGHT STANDARD DUPLEX OUTLET +36" WALL SCONCE GFI P R WP S L CEILING FAN / LIGHT ELECTRICAL LEGEND SMOKE DETECTOR DUAL HEAD EXT. FLOOD F F L RECESSED FAN / LIGHT CAN F EXHAUST FAN R RECESSED DIRECTIONAL WALL MOUNTED STRIP FLUORESCENT UNDER CABINET LIGHT 4 ELECTRICAL PLANS ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF STUART R SHADE, RA. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. SHEET NUMBER: DATE: CERTIFICATION: SRS ARCHITECTS 13245 ALLISONVILLE RD FISHERS, INDIANA 46038 PHONE: 317-989-6248 E-MAIL : stushade@att.net 15 SEPTEMBER, 2016 REV 1: T A N N I A R A T U S A E R I G T S R T R. H S STATE OF E E D D E R E A I D I T C H C AR00034184 PROJECT : GREENFIELD , INDIANA PRIVATE RESIDENCE REVIEW SET 12_8_17 BUILDER : 13590 - NORTH MERIDIAN ST FCC DEVELOPMENT SUITE 100 CARMEL , INDIANA 46032 SCALE: 1 1/4"=1'-0" LEVEL ONE ELECTRICAL SCALE: 2 1/4"=1'-0" LEVEL TWO ELECTRICAL 12 5 12 LINE OF ROOF 5 BEYOND LINE OF SLOPED CEILING BEYOND LINE OF ROOF BEYOND LINE OF SLOPED CEILING BEYOND STAIRS BEHIND WALL 10" 7 3/4" DROPPED LAM BEAM IN BULKHEAD DROPPED LAM BEAM IN BULKHEAD EXTEND WALL TO 10'-0" HIGH - SIMPSON ATTACHMENT ANCHOR NEW LAM BEAM EXIST BLOCK BASE TO REMAIN REMOVE BLOCK INSTALL 12" WOOD COLUMN RAFTER BEARING +10'-8-3/8" 10'-0" 1'-0 5/8" 9'-1 1/8" 2 3 3 3 2'-0" 1'-0" 12'-0" FLASHING 1 x 10 COMP TRIM MTL DRIP EDGE CONT. GUTTER 1 x 6 COMP TRIM COMP SOFFIT W/ AREA VENTS 1 x 8 COMP TRIM SHINGLE ROOF 7/16" OSB SHEATHING 2 x RAFTERS @ 16" CC DORMER BEYOND 3/4" T & G SHEATHING ENGINEERED FLOOR SYSTEM - INSUL WHERE REQUIRED 1/2" GYP CEILING NOTE: EXTEND EXIST WALL TO 10'-0" ABOVE FLOOR - SECURE WITH SIMPSON WALL TIES OR EXTEND NEW STUDS BELOW EXIST PLATE INSULATION NEW COMP LAP SIDE REPLACE SHEATHING AS REQUIRED EXISTING FLOOR 12'-0" FLASHING 1 x 10 COMP TRIM 1/2" GYP CEILING NOTE: EXTEND EXIST WALL TO 10'-0" ABOVE FLOOR - SECURE WITH SIMPSON WALL TIES OR EXTEND NEW STUDS BELOW EXIST PLATE INSULATION NEW COMP LAP SIDE REPLACE SHEATHING AS REQUIRED EXISTING FLOOR 1'-0" MTL DRIP EDGE CONT. GUTTER 1 x 6 COMP TRIM COMP SOFFIT 1 x 8 COMP TRIM 1'-0" MTL DRIP EDGE CONT. GUTTER 1 x 6 COMP TRIM COMP SOFFIT W/ AREA VENTS 1 x 8 COMP TRIM SHINGLE ROOF 7/16" OSB SHEATHING 2 x RAFTERS @ 16" CC AIR BAFFLE SHINGLE ROOF 7/16" OSB SHEATHING 2 x RAFTERS @ 16" CC 1 x 6 COMP TRIM MTL FLASHING LAP COMP SIDING OVER 7/16" OSB 1/2" GYP CLG JOISTS W/ R-38 BATT 1/2" GYP OVER 2 x 4'S @ 16" CC W/ R-13 BATT INSUL ROOF BEYOND 3/4" T & G SHEATHING OVER ENGINEERED JOISTS 2'-0" SHINGLE ROOF 7/16" OSB SHEATHING 2 x RAFTERS @ 16" CC 1'-5" MTL DRIP EDGE CONT. GUTTER 1 x 6 COMP TRIM COMP SOFFIT W/ AREA VENTS 1 x 10 COMP TRIM 10'-8 3/8" 1'-2" 1 x 10 TRIM COMP SOFFIT LAM BEAM 3/4" T & G SHEATHING OVER ENGINEERED JOISTS BEAR RAFTERS BETWEEN FLOOR JOISTS 3 CROSS SECTIONS WALL SECTIONS ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF STUART R SHADE, RA. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. SHEET NUMBER: DATE: CERTIFICATION: SRS ARCHITECTS 13245 ALLISONVILLE RD FISHERS, INDIANA 46038 PHONE: 317-989-6248 E-MAIL : stushade@att.net 15 SEPTEMBER, 2016 REV 1: T A N N I A R A T U S A E R I G T S R T R. H S STATE OF E E D D E R E A I D I T C H C AR00034184 PROJECT : GREENFIELD , INDIANA PRIVATE RESIDENCE REVIEW SET 12_8_17 BUILDER : 13590 - NORTH MERIDIAN ST FCC DEVELOPMENT SUITE 100 CARMEL , INDIANA 46032 SCALE: WALL SECTION 1/2"=1'-0" 2 SCALE: CROSS SECTION 1/4"=1'-0" A-A SCALE: CROSS SECTION 1/4"=1'-0" SCALE: B-B WALL SECTION 1/2"=1'-0" 1 SCALE: WALL SECTION 1/2"=1'-0" 3 LIVING ROOM CEILING HGT. 10'-0" WDH 210510 DINING ROOM CEILING HGT. 10'-0" 12'-1 5/8" 2'-1 1/8" 11'-9 1/2" KITCHEN CEILING HGT. 10'-0" OFFICE CEILING HGT. 10'-0" MUD ROOM CEILING HGT. 10'-0" HALL CL POWDER CEILING HGT. 10'-0" PANTRY CEILING HGT. 10'-0" 3/0 x 6/8 BARN 3/0 x 6/8 2/0 x 6/8 2/4 x 6/8 2/4 x 6/8 2/6 x 6/8 2/4 x 6/8 3/0 x 8/0 3'-8" 6'-5 1/2" 8'-2 3/4" 2'-1 1/2" 3'-0" 1'-1 1/2" WDH 210410 WDH 210410 WDH 210510 WDH 210510 WDH 210510 WDH 20310 (3) WDH 2454 REMOVE AND INSTALL NEW WINDOW NEW WINDOW IN EXIST WALL THICKEN WALL TO RECEIVE DUCT WORK NEW LAM BEAM ON OLD WALL CENTERLINE NOTE: FLOOR PROVIDER TO DESIGN FOR LEVEL TWO WALLS ABOVE 2'-0" NOTE: SET ADDITION ON EXIST CONC SLAB - FLASH BASE AS REQUIRED NOTES: · FINISHED AREA - 962 SQ FT · WINDOW NUMBERS PER ANDERSEN 400 SERIES BED ROOM 2 CEILING HGT. 9'-0" 8'-7 3/4" 7'-6" 5'-0" 2'-0" 11'-8 1/2" 10'-6" 10'-6" 12'-1 3/4" 6'-0 1/2" 2'-11 1/2" 3'-4" 2'-3 1/2" 3'-0" 2'-5 1/8" 12'-0" 5'-10 1/8" 24'-4 1/4" 5'-10 1/8" 6'-4" 6'-4" 5'-10 1/8" 21'-10 1/2" 1'-6" 5'-6 1/2" 10'-9 1/2" 5'-6 1/2" 3'-6" 31'-0 3/4" 5'-7 1/2" 7'-4 3/8" 5'-7 7/8" 13'-4" 4'-8 1/2" 3'-6" 19'-6 1/2" 6'-9 3/4" 4'-8 1/2" 5'-7 1/2" 2'-0" 6'-9" 5'-6 1/2" 2'-0" 8'-6" 4'-6" 2'-8 1/2" 3'-4" 6'-0 3/4" 4'-0" 6'-0" 10'-3 1/2" 11" 11 3/4" 5'-6" BED ROOM 3 CEILING HGT. 9'-0" MASTER BEDROOM CEILING HGT. 9'-0" TO CATHEDRAL 2/4 x 6/8 2/6 x 6/8 2/6 x 6/8 2/6 x 6/8 6/0 x 6/8 6/0 x 6/8 2/4 x 6/8 5/6 x 6/8 FOLD 2/0 x 6/8 FOLD BATH BATH LAUNDRY CLOSET CLOSET CLOSET LANDING 3'-0" 10'-10" 7'-9 1/4" SLOPED SLOPED SLOPED SLOPED FLAT FLAT NOTES: · FINISHED AREA - 874 SQ FT · WINDOW NUMBERS PER ANDERSEN 400 SERIES WDH 2852 EGRESS WDH 2042 WDH 2852 EGRESS WDH 2852 EGRESS WDH 2852 EGRESS WDH 210310 WDH 210310 (3) WTR 2831 LAM BEAM LAM BEAM AREA OF SLOPED CEILING AREA OF SLOPED CEILING 2 x 6 WALL 2'-4" 2'-2" REMOVE DOOR AND PREP FOR NEW WINDOW REMOVE WINDOW AND PREP FOR NEW WINDOW REMOVE UPPER CONC REMOVE UPPER CONC BLOCK FROM COLUMN BLOCK FROM COLUMN REMOVE EXIST WOOD COLUMN - PREP FOR NEW REMOVE EXIST WOOD COLUMN - PREP FOR NEW REMOVE WINDOW REMOVE WINDOW REMOVE WINDOWS CUT WALL FOR NEW WINDOW CUT WALL FOR NEW WINDOW REMOVE EXIST PLUMBING - PREP FOR NEW EXISTING SUB-FLOOR TO REMAIN EXISTING SUB-FLOOR TO REMAIN EXISTING SUB-FLOOR TO REMAIN REMOVE EXIST CHIMNEY REMOVE EXIST BEARING WALL - INSTALL NEW LAM BEAM ON CENTERLINE FOR LEVEL TWO JOISTS REMOVE EXIST BEARING WALL - INSTALL NEW LAM BEAM ON CENTERLINE FOR LEVEL TWO JOISTS REMOVE EXIST STAIRS - PREP FOR NEW REMOVE WINDOW AND PREP FOR NEW WINDOW NOTE: REMOVE EXIST LEVEL TWO FLOOR JOISTS AND ENTIRE ROOF STRUCTURE 2 DEMOLITION FLOOR PLANS SCALE: D 1/4"=1'-0" DEMO PLAN ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF STUART R SHADE, RA. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. SHEET NUMBER: DATE: CERTIFICATION: SRS ARCHITECTS 13245 ALLISONVILLE RD FISHERS, INDIANA 46038 PHONE: 317-989-6248 E-MAIL : stushade@att.net 15 SEPTEMBER, 2016 REV 1: T A N N I A R A T U S A E R I G T S R T R. H S STATE OF E E D D E R E A I D I T C H C AR00034184 PROJECT : GREENFIELD , INDIANA PRIVATE RESIDENCE REVIEW SET 12_8_17 BUILDER : 13590 - NORTH MERIDIAN ST FCC DEVELOPMENT SUITE 100 CARMEL , INDIANA 46032 SCALE: 1 1/4"=1'-0" LEVEL ONE SCALE: 2 1/4"=1'-0" LEVEL TWO COMPOSITE LAP SIDING EXIST FOUNDATION NEW WOOD DECK RAILINGS REQ'D OVER 18" ABOVE GRADE 8'-10 3/4" 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM 1 x 10 BASE TRIM NOTE: INSTALL FLASHING AT TOP OF 1 x TRIM AS REQ'D ALL ROOFS TO ALIGN WITH RIDGE + 11'-0-5/8" LEVEL TWO + 0'-0" LEVEL ONE 12 5 12 5 12 12 9 9 9 : 12 PITCH EXISTING BLOCK BASE TO REMAIN NEW 12" WOOD COLUMNS COMPOSITE LAP SIDING COMPOSITE LAP SIDING COMPOSITE LAP SIDING EXIST FOUNDATION NEW WOOD DECK RAILINGS REQ'D OVER 18" ABOVE GRADE SHINGLE ROOF 8'-10 3/4" 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM 1 x 10 BASE TRIM 1 x 12 BASE TRIM 1 x 10 BASE TRIM NOTE: INSTALL FLASHING AT TOP OF 1 x TRIM AS REQ'D ALL ROOFS TO ALIGN WITH RIDGE 12 9 9 : 12 PITCH 5 : 12 PITCH COMPOSITE LAP SIDING COMPOSITE LAP SIDING EXIST FOUNDATION NEW WOOD DECK RAILINGS REQ'D OVER 18" ABOVE GRADE SHINGLE ROOF SHINGLE ROOF 1 x 6 WINDOW TRIM 1 x 6 WINDOW TRIM 1 x 10 BASE TRIM NOTE: INSTALL FLASHING AT TOP OF 1 x TRIM AS REQ'D ALL ROOFS TO ALIGN WITH RIDGE RIDGE W/ VENT LAM BEAM 5/12 SHED DORMER 5/12 SHED DORMER INCREASED OVERHANG DETAIL PRIOR TO CONSTRUCTION 9/12 PITCH ROOF 9/12 PITCH ROOF 9/12 PITCH ROOF 9/12 PITCH ROOF CATHEDRAL CEILING BELOW 1 EXTERIOR ELEVATIONS SCALE: R 1/4"=1'-0" ROOF PLAN ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF STUART R SHADE, RA. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. SHEET NUMBER: DATE: CERTIFICATION: SRS ARCHITECTS 13245 ALLISONVILLE RD FISHERS, INDIANA 46038 PHONE: 317-989-6248 E-MAIL : stushade@att.net 15 SEPTEMBER, 2016 REV 1: T A N N I A R A T U S A E R I G T S R T R. H S STATE OF E E D D E R E A I D I T C H C AR00034184 PROJECT : GREENFIELD , INDIANA PRIVATE RESIDENCE REVIEW SET 12_8_17 BUILDER : 13590 - NORTH MERIDIAN ST FCC DEVELOPMENT SUITE 100 CARMEL , INDIANA 46032 SCALE: N 1/4"=1'-0" NORTH ELEVATION SCALE: E 1/4"=1'-0" EAST ELEVATION SCALE: S 1/4"=1'-0" SOUTH ELEVATION SCALE: W 1/4"=1'-0" WEST ELEVATION