Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.2 ELEC. DATA_REFLECTED CEILING PLANS
Project Number: Sheet Title: Issue Date: Sheet Number: Project: CARMEL, INDIANA 46032 By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RARE BIRD Print Date Drawn By Checked By Revisions: 200 SOUTH RANGE LINE ROAD SUITE 244 INDIANA DESIGN CENTER COPYRIGHT & OWNERSHIP OF DOCUMENTS SERVER PLOTTER DESK 30X60 CREDENZA 18X36 DP5 A1.2 ELEC. DATA/ REFLECTED CEILING PLANS Parcel 12 PEDCOR DESIGN GROUP, LLC 1/24/18 CONSTRUCTION DOCUMENTS 1/24/18 STATE RELEASE THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. KEY PLAN SCALE: N.T.S. SECOND FLOOR N N SUSPENDED CEILING HEIGHT IS 10'-0" A.F.F. UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 PROVIDE NEW SUSPENDED CEILING SYSTEM TO MATCH BUILDING STANDARD CEILING SYSTEM. CEILING SYSTEM TO BE: ARMSTRONG, DUNE ANGLED TEGULAR 2'X2'X5/8" W/ PRELUDE 15/16" GRID. 7. 6. 5. 4. 1. 2. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. CP2 CP3 CP4 PROVIDE NEW SUSPENDED CEILING CLOUD TO BE THREE (3) OPTIMA CAPZ REVERSE TEGULAR 3936 PANELS OPTIMA WHITE. CONTACT PHIL CAITO, 317.519.2829. CP5 PENDANT LIGHTS TO BE ON THEIR OWN TIMED CIRCUIT. CP6 CP7 NL EMERGENCY/NIGHTLIGHT LOCATION. GYPSUM BOARD BULKHEAD. NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, DUNE ANGLED TEGULAR 2'X2'X5/8" WITH PRELUDE XL 15/16" EXPOSED TEE GRID. REFLECTED CEILING LEGEND: 6" RECESSED DOWNLIGHT FIXTURES TO BE: CREE 6" LED RECESSED DOWNLIGHT, LR6C, LR6C-10L, 3500 W/RC6 HOUSING. LIGHTS TO BE DIMMABLE. A B DRYWALL BULKHEAD WITH BLOCKING FOR DRAPERY PANEL TRACK. SEE SECTION 8/A4.1 FOR DETAILS. CP8 REVIEW EXISTING HVAC DESIGN AND INCLUDE RENOVATIONS NEEDED FOR NEW TENANT. CP9 LIGHTS TO BE CONTROLLED BY INDIVIDUAL MOTION SENSORS WITH OVERRIDE SWITCHES IN EACH ROOM. MOTION SENSORS TO FACE INWARD TO AVOID MOVEMENT THROUGH GLASS. CP10 RELOCATE TYPE R TRACK LIGHT FIXTURES REMOVED DURING DEMOLITION. LIGHTS AT THE ENTRY DOORS TO BE ON A 24-HOUR NIGHTLIGHT CIRCUIT. CP11 ALL ELECTRICAL IN NEW TENANT SPACE TO BE REMOVED FROM EXISTING TENANT'S PANEL AND TIED INTO A DEDICATED PANEL. 8. 2 X 2 LED TROFFERS TO BE: CREE 2'X2' LED TROFFER ZR22-32L-35K-10V. C NOT USED. D DECORATIVE PENDANT FIXTURE TO BE: LAMPS PLUS, AVENUE ROBERTSON BLVD. 8" BLACK MINI PENDANT #12T34. LOCATION OF LIGHTING TIMER SYSTEM. PROVIDE SEPARATE CIRCUITS ON A TIMER FOR THE OPEN OFFICE AREA. PUT EVERY OTHER ROW ON THE SAME CIRCUIT TO ALLOW MULTIPLE LIGHT LEVELS. GENERAL CEILINGS ARE TO BE OPEN WITH ALL EXPOSED HVAC UNITS, DUCTWORK, AND CONDUIT TO BE PAINTED P3. PROVIDE SMOKE DETECTORS AND LIFE SAFETY ITEMS AS REQUIRED. ADD OR RELOCATE FIRE PROTECTION SPRINKLERS AS REQUIRED. ALL ELECTRICAL IN SOUTH TENANT SPACE TO BE REMOVED FROM EXISTING PANEL AND TIED INTO NORTH TENANT SPACE. ALL ELECTRICAL TO BE TIED TO METER 106983401. 9. CP12 PROVIDE DIMMERS FOR LIGHT FIXTURES. ILLUMINATED EXIT SIGN. LITHONIA LIGHTING, SURFACE MOUNT EDGE LIT EXIT LIGHT, EDG 1R 120/277 ELN OR EQUAL. EMERGENCY NIGHT LIGHTS. PROVIDE EMERGENCY LIGHTS AS REQUIRED AND DETERMINED BY MEP CONSULTANT. FIXTURES ARE TO BE: MERCURY LIGHTING, MER-R1. CP13 PROVIDE SEPARATE CONTROL FOR THESE TWO (2) LIGHT FIXTURES. 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" OPEN 10'-0" 10'-0" 10'-0" 10'-0" 8 A4.1 8 A4.1 CP1 CP4 CP1 CP4 CP1 CP4 CP1 CP4 CP1CP10 CP6 CP11 CP5 CP5 CP3 CP7 CP11 CP11 CP10 CP11 CP10 CP11CP10 CP9 CP10 CP8 CP11 CP10 CP1 CP2 CP2 CP12 CP4 CP12 CP12 CP12 CP12 CP13 B R R R R R R R R R R R R R R R R R R R R A A A A A A A A A A A A A A B B B B B B B B B D D D NL A NL D D D B B .6 .5 1 3 2.9 2 J K K.1 K.5 L L.6 F J D T DW J D J D EP2 EP3 EP7 EP2 EP3 EL7 EP3 EP7 EP4 EP2 EP3 EL6 EP7 EP3 EP5 EP1 EP2 EP3 EP7 EP2 EP3 EP7 EP7 EP4 EP2 EP2 EP8 EL6 EL6 OFFICE SUITE 244 3,176 RSF RECEPTION 201 ENTRY 200 OFFICE 205 FLEX SPACE 204 OFFICE 206 OFFICE 207 N N N N N D N +44 GFI N +44 GFI +60 N +60 N N N N N N N D N N N N N N N N N N +60 N +60 N N T STORAGE 203 MARKER BOARD OPEN WORKSPACE 211 COAT CLOSET BREAK AREA 210 CONFERENCE 208 OPEN FLEX SPACE 209 MARKER BOARD .6 .5 1 3 2.9 2 J T D GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. JUNCTION BOXES IN OPEN CEILING AREAS TO HAVE RIDGID CONDUIT EXTENDING TO DECK ABOVE. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY PEDCOR IT UNLESS OTHERWISE INDICATED. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 5. 6. 4. 3. TIE ALL ELECTRICAL FROM SOUTH HALF OF THE SUITE INTO NEW SUITE ELECTRICAL PANEL. LOCATION OF ELECTRICAL PANEL. SEE NOTE 9. EP1 EP2 PROVIDE ELECTRICAL SUPPLY AND DATA BOXES AS SHOWN WITH AN "N". DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET. D ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +54" HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. PROVIDE DATA WIRING, PHONE SERVICE, AND INTERNET SERVICE. PULL CABLE AND INCLUDE CONNECTIONS FOR PHONE AND DATA AT NEW DATA LOCATIONS. COORDINATE ELECTRICAL WITH TENANT PROVIDED EQUIPMENT. EP3 7. ALL ELECTRICAL IN SOUTH TENANT SPACE TO BE REMOVED FROM EXISTING PANEL AND TIED INTO NORTH TENANT SPACE. ALL ELECTRICAL TO BE TIED TO METER 106983401. PROVIDE POWER AND DATA AT 60" AFF AND INSTALL BLOCKING FOR TV. TV SUPPLIED AND INSTALLED BY TENANT. EP4 EP5 PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED REFRIGERATOR. PROVIDE ELECTRICAL JUNCTION BOX AND DATA BOX AT THE DECK ABOVE FOR SYSTEMS FURNITURE POWER POLE. INCLUDE FOUR (4) CIRCUITS AT ELECTRICAL JUNCTION BOX. INCLUDE CONNECTION OF TENANT PROVIDED POWER POLE IN-FEED. EP6 ALL FURNITURE, FIXTURES, AND EQUIPMENT TO BE SUPPLIED BY TENANT UNLESS NOTED OTHERWISE. EP7 MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. 8. 9. CEILING MOUNTED JUNCTION BOX AND DATA BOX. THERMOSTAT. EP8 PROVIDE ELECTRICAL FOR TENANT PROVIDED DISHWASHER. J K K.1 K.5 L L.6 SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2 BNR MC