Loading...
HomeMy WebLinkAboutT1.5 SECOND LEVEL LIFE SAFETY PLANProject Number: Sheet Title: Issue Date: Sheet Number: Project: CARMEL, INDIANA 46032 By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RARE BIRD Print Date Drawn By Checked By Revisions: 200 SOUTH RANGE LINE ROAD SUITE 244 INDIANA DESIGN CENTER COPYRIGHT & OWNERSHIP OF DOCUMENTS SERVER PLOTTER DESK 30X60 CREDENZA 18X36 DP5 T1.5 SECOND LEVEL LIFE SAFETY PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC 1/24/18 CONSTRUCTION DOCUMENTS 1/24/18 STATE RELEASE THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. KEY PLAN SCALE: N.T.S. SECOND FLOOR N K.5 22 K K.1 K.5 3 2.9 3.8 3.3 G.3 G.4 H H.5 J K K.1 K.5 L L.6 L.7 L.9 M .6 .5 1 F 5 7 G 6 3 2.9 2 8 8.1 A.1 C E 10 4 H.9 11 9.1 8.15 9.9 10.9 10.85 7.8 7.3 3.8 3.3 .5A A A.2 B D 9 F 22 K K.1 K.5 3 2.9 3.8 3.3 G DW SECOND FLOOR OFFICE 3,176 SQ. FT 138'-11" 116'-11" 80'-2" BUILDING CODES: SPRINKLER SYSTEM: PROJECT BUILDING CODES BUILDING HEIGHT: OCCUPANCY LOAD: 32 PERSONS PER TABLE 1004.1.2. FULLY PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM AS PER NFPA 13 - 2010 CODE COMPLIANCE SCHEDULE OCCUPANCY Group B - Office Use Group CONSTRUCTION TYPE: Type II-B - Non-combustible construction materials; Non-rated PROJECT AREA: APPROVALS: PROJECT NO. 323831 CDR LETTER FOUNDATION RELEASE 02.02.07 PROJECT NO. 323831 CDR LETTER STANDARD RELEASE - ARCHITECTURAL 02.16.07 PROJECT NO. 323831 CDR LETTER STANDARD RELEASE - MEP 02.04.08 FIREWALL VARIANCE NO. 10-04-57 (A,B,C,D) 04.06.10 2 STORY. 3,176 S.F. GROSS TENANT AREA Indiana Building Code, 2014 Edition (IBC 2012) Indiana Accessibility Code (ICC/ANSI A117.1-2009) Minimum Design Loads (ASCE 7-2010) Indiana Plumbing Code, 2012 Edition (IPC 2006) Indiana Mechanical Code, 2014 Edition (IMC 2012) Indiana Fuel Gas Code, 2014 Edition (IFGC 2012) NFPA 10-2010 Portable Fire Extinguishers 2014 2014 2014 2012 2014 2014 2014 Indiana Electrical Code, 2009 Edition (NFPA 70-2008) 2009 General Administrative Rules (675 IAC 12) 2006 NFPA 13-2010 Installation of Sprinkler Systems 2014 NFPA 14-2010 Edition, Installation of Standpipes 2014 NFPA 72-2010 National Fire Alarm Code 2014 Indiana Energy Conservation Code, 2010 Edition (IECC 2007) 2014 SCALE: 1/16" = 1'-0" 1 SECOND LEVEL LIFE SAFETY PLAN T1.5 BNR MC