HomeMy WebLinkAbout007 - A211 - Construction Floor PlanDN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
A501
1
Typ.
12' - 0" +/-
5' - 0 5/8"
12' - 7 3/4"
13' - 0 5/8"
M3
G
M3S
D
M3S
D
M3S
D
M3S
D
M3S
D
M3S
D
M3S
D
M3S.1
+6"
M3
G
M3S
D
M3S
D
M3S
D
M3S
D
M3S
D
M3S
D
M3S.1
+6"
M3S.1
+6"
M3S.1
+6"
M3.1
G
M3.1
D
M5
B
M5
B
M3S
D
M3S.1
D
2' - 6"
6' - 2" +/-
9' - 3 5/8" +/-
413
412
410
409 408 407 406 405 404 403
402
417
C1
C1
C1
C1 C1 C1 C1
M3.1
G
M3.1
G
M3S.1
D
M3S.1
D
M3S.1
D
Office
403
Office
404
Office
405
Office
406
Office
407
Office
408
Office
409
Office
410
Lounge
411
Office
412
Office
413
Conference
414
Breakroom
401
Wellness/Conference
417
Janitor
IT / Storage
419
M3S
+6"
M3S
+6"
Open Office
415
Corridor
420
Corridor
421
Copy
416
Storage
402
2"
M2.1
G
82°
M1.1
G
M5
B
M5
B
4"
2"
2"
2"
M3S.1
D
M2.1
G
M1.1
G
M1.1
M2.1 G
G
M2.1
G
1
2
3
4
5
6
7
8
P1
A B C D E F G H
2 A501
A501
3
M3.1
G
M2.1
G
M2.1
G
M1.1
G
Entrance
400
A501
4
A501
5
A270
1
min.
4' - 3"
A270
2
C2
C2
C3
82°
4' - 6" +/-
4' - 4 7/8" +/-
82°
1
1
1
1
1
M3.1
G
M2.1
G
M3.1
G
M3.1
G
1
1
1
C4
1
414
GI G
Suspended acoustical
ceiling tile - refer to
room finish schedule.
Refer to wall type
schedule for wall
construction.
+6"
Sound batt insulation
above ceiling. Extend
2'-0" min. each side of
wall.
6"
D
Framed to
deck above
Attach deflection slip
track to underside of
deck. Provide sealant
for acoustical and/or
fire rated wall types as
designated.
U.L. Listed fire rated
sealant (1/4 bead) @ fire
rated wall types. Refer
to UL assembly and/or
acoustical manufacturer
guidelines.
Framed to ceiling
grid
Framed to ceiling grid.
Insulate ceiling 2'-0" (min.)
each side of wall
Frame wall to 6" above
ceiling
Suspended acoustical
ceiling tile - refer to
room finish schedule.
Refer to wall type
schedule for wall
construction.
Sound batt insulation
above ceiling. Extend
2'-0" min. each side of
wall.
Continuous acoustical
tape, typ
Spacer as required, typ
Suspended acoustical
ceiling tile - refer to
room finish schedule.
Refer to wall type
schedule for wall
construction.
Sound batt insulation
above to extend above
ceiling 4'-0".
Suspended acoustical
ceiling tile - refer to
room finish schedule.
Refer to wall type
schedule for wall
construction.
Metal top track
channel, continuous,
install fasteners at 2'-0"
o.c., max
USG or Eq. 200-B Metal
"L" Trim continuous,
floated-in, typical.
Continuous acoustical
tape, typ
Spacer as required, typ
Provide bracing to
structure to provide
adequate lateral
stability to the wall
assembly.
USG or Eq. 200-B Metal
"L" Trim continuous,
floated-in, typical.
Metal top track
channel, continuous,
install fasteners at 2'-0"
o.c., max
Existing Partition to
Remain
Existing Shell of Building
Structure
M3
D
Type of Wall Stud
M=Metal Stud Framing
Wall Stud Size / Type
1=Metal Hat Channel
2=2 1/2" Stud Size
3=3 5/8" Stud Size
6=6" Stud Size
S=Sound Insulation
F=Fire Rated
.1=One Side of Gypsum Board
Top of Wall Conditions
(See Standard Top of Wall
Condition Details)
G=Grid
GI=Grid / Insulation
+6=+6 Above Grid
D=Framed to Deck Above
R=Fire Rated
B=Framed to Bulkhead Above
New Partition - Non-Insulated
New Partition Insulated
Construction Key
Note(s)
Miscellaneous Specialty Item
and/or Equipment - refer to
Miscellaneous Specialties and
Equipment Schedule
101 Door - Refer to Door Schedule
Indicates area not in
contract. Refer to
floor plans for
additional information.
1 CONSTRUCTION 1/8" = 1'-0" FLOOR PLAN
1/2" = 1'-0"
TOP OF WALL CONDITION DETAILS
PLAN LEGEND
GENERAL NOTES - CONSTRUCTION
A. REFER TO GENERAL NOTES AND REFERENCE SPECIFICATIONS ON SHEET A001 & A021 FOR
SPECIFICATIONS REGARDING NEW CONSTRUCTION AND FINISHES.
B. Refer to Reflected Ceiling Plans (A22 Series Sheets) for ceiling heights unless otherwise
indicated.
C. Refer to Electrical Location Plans (A23 Series Sheets) for additional Miscellaneous
Specialties & Equipment items that may not be indicated on this sheet.
D. Refer to Finish Plan and Finish Notes (A24 Series Sheets) for wall base type and ceiling
types.
E. Refer to top of wall condition details, this sheet, for additional information regarding
wall heights and termination.
F. Provide air-tight acoustical and/or fire-rated sealant around perimeter of all wall types
with acoustical insulation.
G. All joints and penetrations of fire rated assemblies to be sealed with approved U.L.
listed "F" and "T" systems. Submit product data and installation information prior to
installation for Architect's approval. Label/identify fire rated partitions for future
reference on each side of wall above ceiling, concealed from view. Note the UL
assembly designation with 6" red stenciled letters
H. Dimensions are taken from the face of masonry walls, column centerlines, finish face of
existing walls and/or stud face of new walls unless otherwise indicated.
J. Verify all critical dimensions within and/or related to the existing building. Dimensions
and conditions indicated were determined by visual survey and/or information from
existing drawings.
K. +/- Dimension is equal to verify in field.
L. Plans are not to be scaled for finish or wall information. Contractor to contact
Architect for any questions or clarifications on plan dimensions.
M. Walls behind and directly adjacent to all toilet room fixtures (lavatories, toilets and
urinals) shall have a smooth, hard, non-absorbant surface. Partitions in these areas
shall be constructed with cement board or moisture resistant gypsum board in lieu of
gypsum wall board and/or finished with an epoxy paint. Toilet room accessories (grab
bars, toilet paper dispensers, etc.) in these areas shall be installed and sealed to
prevent moisture penetration.
N. Provide tile backer board at locations to receive wall tile. Refer to the Finish Plan sheet
A204 for locations.
P. Contractor shall verify the size and location of all required mechanical pads and wall
openings.
Q. All walls shall be type "M3SD" unless otherwise noted.
R. All column build outs to be constructed at smallest dimension possible.
KEYED NOTES - CONSTRUCTION
C1 Align center line of new wall construction with centerline of exterior wall
construction Refer to typical detail, sheet 3/A001.
C2 Align wall construction with existing wall. Refer to typical detail, sheet 4/A001.
C3 Provide water line and drain for icemaker, final location TBD.
C4 Contstruct partions based on shower pan specified. GC to select shower pan.
Shower pan must be ADA compliant.
SHEET NUMBER:
COPYRIGHT 2015 CARSON DESIGN ASSOCIATES
JOB NO.
DATE:
DRAWING TITLE:
STAMP:
ISSUE:
MIDWEST
SOUTHWEST
12301 Research Blvd
Bldg IV - Suite 130
Austin, TX 78759
Tel 512.977.0520 Fax 512.977.0384
www.carsondesign.com
9229 Delegates Row
Suite 250
Indianapolis, IN 46240
Tel 317.843.5979 Fax 317.843.5975
A211
I1720009
01.31.18
Construction Floor
Plan
211 W. Main St., Carmel, IN 46032
Invesque, Inc.
Monon & Main
Suite 400
01.31.18
Construction Documents -
Addendum No.1 01.31.18
SCHEDULE - WALL TYPES
Wall Type
Wall Construction Top of Wall Construction
Stud Size Insulation Fire Rating U.L. or G.A. # Description Code Description
M1.1 0' - 0 7/8" No -- Metal Hat Channels w/ (1) layer 5/8" gypsum
board
G Frame wall to 6" above ceiling
M2.1 0' - 2 1/2" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board
G Frame wall to 6" above ceiling
M3 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board each side
D Framed to deck above
M3 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board each side
G Framed to ceiling grid, Insulate ceiling 2'-0" (min.)
each side of wall
M3.1 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board
D Framed to deck above
M3.1 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board
G Framed to ceiling grid
M3S 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board each side
+6" Frame wall to 6" above ceiling
M3S 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board each side
D Framed to deck above
M3S.1 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board
+6" Frame wall to 6" above ceiling
M3S.1 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board
D Framed to deck above
M5 0' - 5 1/2" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum
board each side
B Framed to bulkhead above
0'
1/8" = 1'-0"
8' 4' 8' 16'
PLAN
1
1
1 Addendum No. 1 12.28.17
02/26/18
Nick Mishler