HomeMy WebLinkAbout007 - A211 - Construction Floor PlanDN ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN A501 1 Typ. 12' - 0" +/- 5' - 0 5/8" 12' - 7 3/4" 13' - 0 5/8" M3 G M3S D M3S D M3S D M3S D M3S D M3S D M3S D M3S.1 +6" M3 G M3S D M3S D M3S D M3S D M3S D M3S D M3S.1 +6" M3S.1 +6" M3S.1 +6" M3.1 G M3.1 D M5 B M5 B M3S D M3S.1 D 2' - 6" 6' - 2" +/- 9' - 3 5/8" +/- 413 412 410 409 408 407 406 405 404 403 402 417 C1 C1 C1 C1 C1 C1 C1 M3.1 G M3.1 G M3S.1 D M3S.1 D M3S.1 D Office 403 Office 404 Office 405 Office 406 Office 407 Office 408 Office 409 Office 410 Lounge 411 Office 412 Office 413 Conference 414 Breakroom 401 Wellness/Conference 417 Janitor IT / Storage 419 M3S +6" M3S +6" Open Office 415 Corridor 420 Corridor 421 Copy 416 Storage 402 2" M2.1 G 82° M1.1 G M5 B M5 B 4" 2" 2" 2" M3S.1 D M2.1 G M1.1 G M1.1 M2.1 G G M2.1 G 1 2 3 4 5 6 7 8 P1 A B C D E F G H 2 A501 A501 3 M3.1 G M2.1 G M2.1 G M1.1 G Entrance 400 A501 4 A501 5 A270 1 min. 4' - 3" A270 2 C2 C2 C3 82° 4' - 6" +/- 4' - 4 7/8" +/- 82° 1 1 1 1 1 M3.1 G M2.1 G M3.1 G M3.1 G 1 1 1 C4 1 414 GI G Suspended acoustical ceiling tile - refer to room finish schedule. Refer to wall type schedule for wall construction. +6" Sound batt insulation above ceiling. Extend 2'-0" min. each side of wall. 6" D Framed to deck above Attach deflection slip track to underside of deck. Provide sealant for acoustical and/or fire rated wall types as designated. U.L. Listed fire rated sealant (1/4 bead) @ fire rated wall types. Refer to UL assembly and/or acoustical manufacturer guidelines. Framed to ceiling grid Framed to ceiling grid. Insulate ceiling 2'-0" (min.) each side of wall Frame wall to 6" above ceiling Suspended acoustical ceiling tile - refer to room finish schedule. Refer to wall type schedule for wall construction. Sound batt insulation above ceiling. Extend 2'-0" min. each side of wall. Continuous acoustical tape, typ Spacer as required, typ Suspended acoustical ceiling tile - refer to room finish schedule. Refer to wall type schedule for wall construction. Sound batt insulation above to extend above ceiling 4'-0". Suspended acoustical ceiling tile - refer to room finish schedule. Refer to wall type schedule for wall construction. Metal top track channel, continuous, install fasteners at 2'-0" o.c., max USG or Eq. 200-B Metal "L" Trim continuous, floated-in, typical. Continuous acoustical tape, typ Spacer as required, typ Provide bracing to structure to provide adequate lateral stability to the wall assembly. USG or Eq. 200-B Metal "L" Trim continuous, floated-in, typical. Metal top track channel, continuous, install fasteners at 2'-0" o.c., max Existing Partition to Remain Existing Shell of Building Structure M3 D Type of Wall Stud M=Metal Stud Framing Wall Stud Size / Type 1=Metal Hat Channel 2=2 1/2" Stud Size 3=3 5/8" Stud Size 6=6" Stud Size S=Sound Insulation F=Fire Rated .1=One Side of Gypsum Board Top of Wall Conditions (See Standard Top of Wall Condition Details) G=Grid GI=Grid / Insulation +6=+6 Above Grid D=Framed to Deck Above R=Fire Rated B=Framed to Bulkhead Above New Partition - Non-Insulated New Partition Insulated Construction Key Note(s) Miscellaneous Specialty Item and/or Equipment - refer to Miscellaneous Specialties and Equipment Schedule 101 Door - Refer to Door Schedule Indicates area not in contract. Refer to floor plans for additional information. 1 CONSTRUCTION 1/8" = 1'-0" FLOOR PLAN 1/2" = 1'-0" TOP OF WALL CONDITION DETAILS PLAN LEGEND GENERAL NOTES - CONSTRUCTION A. REFER TO GENERAL NOTES AND REFERENCE SPECIFICATIONS ON SHEET A001 & A021 FOR SPECIFICATIONS REGARDING NEW CONSTRUCTION AND FINISHES. B. Refer to Reflected Ceiling Plans (A22 Series Sheets) for ceiling heights unless otherwise indicated. C. Refer to Electrical Location Plans (A23 Series Sheets) for additional Miscellaneous Specialties & Equipment items that may not be indicated on this sheet. D. Refer to Finish Plan and Finish Notes (A24 Series Sheets) for wall base type and ceiling types. E. Refer to top of wall condition details, this sheet, for additional information regarding wall heights and termination. F. Provide air-tight acoustical and/or fire-rated sealant around perimeter of all wall types with acoustical insulation. G. All joints and penetrations of fire rated assemblies to be sealed with approved U.L. listed "F" and "T" systems. Submit product data and installation information prior to installation for Architect's approval. Label/identify fire rated partitions for future reference on each side of wall above ceiling, concealed from view. Note the UL assembly designation with 6" red stenciled letters H. Dimensions are taken from the face of masonry walls, column centerlines, finish face of existing walls and/or stud face of new walls unless otherwise indicated. J. Verify all critical dimensions within and/or related to the existing building. Dimensions and conditions indicated were determined by visual survey and/or information from existing drawings. K. +/- Dimension is equal to verify in field. L. Plans are not to be scaled for finish or wall information. Contractor to contact Architect for any questions or clarifications on plan dimensions. M. Walls behind and directly adjacent to all toilet room fixtures (lavatories, toilets and urinals) shall have a smooth, hard, non-absorbant surface. Partitions in these areas shall be constructed with cement board or moisture resistant gypsum board in lieu of gypsum wall board and/or finished with an epoxy paint. Toilet room accessories (grab bars, toilet paper dispensers, etc.) in these areas shall be installed and sealed to prevent moisture penetration. N. Provide tile backer board at locations to receive wall tile. Refer to the Finish Plan sheet A204 for locations. P. Contractor shall verify the size and location of all required mechanical pads and wall openings. Q. All walls shall be type "M3SD" unless otherwise noted. R. All column build outs to be constructed at smallest dimension possible. KEYED NOTES - CONSTRUCTION C1 Align center line of new wall construction with centerline of exterior wall construction Refer to typical detail, sheet 3/A001. C2 Align wall construction with existing wall. Refer to typical detail, sheet 4/A001. C3 Provide water line and drain for icemaker, final location TBD. C4 Contstruct partions based on shower pan specified. GC to select shower pan. Shower pan must be ADA compliant. SHEET NUMBER: COPYRIGHT 2015 CARSON DESIGN ASSOCIATES JOB NO. DATE: DRAWING TITLE: STAMP: ISSUE: MIDWEST SOUTHWEST 12301 Research Blvd Bldg IV - Suite 130 Austin, TX 78759 Tel 512.977.0520 Fax 512.977.0384 www.carsondesign.com 9229 Delegates Row Suite 250 Indianapolis, IN 46240 Tel 317.843.5979 Fax 317.843.5975 A211 I1720009 01.31.18 Construction Floor Plan 211 W. Main St., Carmel, IN 46032 Invesque, Inc. Monon & Main Suite 400 01.31.18 Construction Documents - Addendum No.1 01.31.18 SCHEDULE - WALL TYPES Wall Type Wall Construction Top of Wall Construction Stud Size Insulation Fire Rating U.L. or G.A. # Description Code Description M1.1 0' - 0 7/8" No -- Metal Hat Channels w/ (1) layer 5/8" gypsum board G Frame wall to 6" above ceiling M2.1 0' - 2 1/2" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board G Frame wall to 6" above ceiling M3 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board each side D Framed to deck above M3 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board each side G Framed to ceiling grid, Insulate ceiling 2'-0" (min.) each side of wall M3.1 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board D Framed to deck above M3.1 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board G Framed to ceiling grid M3S 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board each side +6" Frame wall to 6" above ceiling M3S 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board each side D Framed to deck above M3S.1 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board +6" Frame wall to 6" above ceiling M3S.1 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board D Framed to deck above M5 0' - 5 1/2" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board each side B Framed to bulkhead above 0' 1/8" = 1'-0" 8' 4' 8' 16' PLAN 1 1 1 Addendum No. 1 12.28.17 02/26/18 Nick Mishler