HomeMy WebLinkAbout009 - A231 - Electrical Location & Equipment PlanDN
GFCI
+42"
+42"
+42"
+42"
+42" GFCI
D
D
+54"
1/1
+54"
+54" TV
+54" TV
+54" TV
D
D
+54"
U181813 U183013F
F183013U U181813
U181813
U183013F U181813
F183013U
181840BCR 181840BCL
181840BCR 181840BCL
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
RS3078TL RS3078TR
RS3078TL RS3078TR
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4 1033.BK2.T.AR4
1033.BK2.T.AR4
U181813
U183013F U181813
F183013U
U181813 U183013F
F183013U U181813
181840BCR 181840BCL
181840BCR 181840BCL
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
RS3078TL RS3078TR
RS3078TL RS3078TR
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
1033.BK2.T.AR4
1033.BK2.T.AR4
U181813
U183013F U181813
F183013U
U181813 U183013F
F183013U U181813
181840BCR 181840BCL
181840BCR 181840BCL
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
RS3078TL RS3078TR
RS3078TL RS3078TR
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
1033.BK2.T.AR4
1033.BK2.T.AR4
U181813
U183013F U181813
F183013U
U181813 U183013F
F183013U U181813
181840BCR 181840BCL
181840BCR 181840BCL
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
RS3078TL RS3078TR
RS3078TL RS3078TR
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
1033.BK2.T.AR4
1033.BK2.T.AR4
U181813 U183013F
F183013U U181813
U181813
U183013F U181813
F183013U
181840BCR 181840BCL
181840BCR 181840BCL
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
MTL228
RS3078TL RS3078TR
RS3078TL RS3078TR
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
DMD4410
DP3040
DMD4410
DP3040
1033.BK2.T.AR4
1033.BK2.T.AR4
1033.BK2.T.AR4
1
2
3
4
5
6
7
8
P1
A B C D E F G H
E1
E1
E1
E1
E1
E1 E1
E1
E1
Office
403
Office
404
Office
405
Office
406
Office
407
Office
408
Office
409
Office
410
Lounge
411
Office
412
Office
413
Conference
414
Open Office
415
Corridor
421
Corridor
400
IT / Storage
419
Wellness/Conference
417
Janitor
RESTROOM
RESTROOM
Shower
416
Entrance
400
Elevator
STAIR 4
STAIR 3
Copy
416
E3
E3 E3 E3 E3
E3
E3
E3
E2
E5
E6
E1
E3
E6
E4
Breakroom
401
Storage
402
E4
E7
E3
9' - 11"
EQ. EQ.
E8 E8
E8
1
1
E8
1
E9
E2
E7
E8
TA20 TA20
TA20
TA20 TA20 TA20
TA20
TA20
TA20
TA20
+42"
Wall mounted dedicated duplex
outlet on dedicated circuit at
standard height.
Special mounting height indication
for wall outlets. Taken to centerline.
Wall mounted electrical
J-box outlet
Thermostat
Wall mounted duplex outlet
at standard height.
Wall mounted duplex ground
fault circuit interrupt outlet at
standard height.
Wall mounted data outlet.
Wall mounted audio / video box.
Wall mounted cable television box.
Wall mounted telephone and data
shared outlet (1 Data / 1 Voice
U.O.N.)
Wall mounted quadruplex outlet
at standard height.
Wall mounted quadruplex ground
fault circuit interrupt outlet at
standard height.
Floor mounted power
and/or data
Ceiling mounted electrical J-box
outlet
Miscellaneous Specialty Item
and/or Equipment - refer to
Miscellaneous Specialties and
Equipment Schedule
Indicates area not in
contract. Refer to floor
plans for additional
information.
1i
NOTE: Standard outlet height is 18" A.F.F. (U.O.N.)
3
Indicates switching type
(3, 4, D, K, K3, OS)
Wall mounted switch
1. Refer to attached M, E, & P drawings for more information. If drawings are not
included and scope requires M, P, or E work Contractor shall provide design build-
design and permitting services for the scope required for a successful project.
2. The design and installation of all MEP systems shall comply with the current Codes
in force by the AHJ at the project location. Any required energy compliance or
environmental reports required by the AHJ shall be prepared by the Contractor if
not provided by the Owner or Architect’s consultants.
3. Contractor to field verify all existing building conditions and systems affected by
the project work and be familiar with the drawings and project requirements prior
to bid or contracting with Owner. No structural cutting, coring, or drilling shall be
performed that impacts any part of the existing facility, without prior approval.
Contractor shall retain the services of a structural engineer, if required by the
Architect, Owner, or AHJ to obtain a required approval.
4. Architectural drawing have been provided to show the locations of all devices
and systems. Contractor shall be responsible for reconfigurations, modifications,
and/or new work needed to provide a complete functioning job without
permanently disrupting existing building systems. Contractor shall coordinate with
Owner, Building Facilities, and or other Tenants 48 hours minimum in advance of
any interruption of any building service.
5. Architectural drawings shall take precedence over all other trades drawings
when conflicts arise. Contractor to bring conflicts or inconsistencies between the
architectural drawings and the drawing of other trades to the attention of the
architect prior to bid, order, or installation.
6. Fire sprinkler modifications and new work shall be designed by a licensed fire
sprinkler system designer in the state the project resides in, and must be installed
by a state licensed installer. Contractor shall obtain any required approvals from
the AHJ prior to start of construction.
7. Zoning of MEP systems shall be exclusive to the project area without cross over to
other building areas, except as is indicated on the documents or as approved in
advance.
8. Contractor to provide all required test and balance reports, O&M manuals, and
commissioning activities required by the AHJ or project requirements in the
appropriate phases of the project.
Note: E.C. and/or design build contractor is to verify that project meets Indiana ASHRAE
90.1 energy codes. Design intent is to be within watts per square foot. Provide energy
managment controls, such as sensor controls (ultrasonic and motion detection) and/or
relay time clocks, as required by the code. Indiana required energy compliance report
(ComCheck) is the responsibility of the owner or owner's representative. Drawings,
specifications and energy control devices are shown with the intent of meeting current
state energy codes. Submitting party is to alert designer and owner of any additional
devices or load changes necessary to adhere to the code prior to submission of
ComCheck.
1 ELECTRICAL 1/8" = 1'-0" LOCATION & EQUIPMENT PLAN
ELECTRICAL LEGEND
MECH, ELEC, & PLUMBING DESIGN REQ.
GENERAL NOTES - ELECTRICAL
A. REFER TO GENERAL NOTES AND REFERENCE SPECIFICATIONS ON SHEET A001 & A021 FOR
SPECIFICATIONS REGARDING NEW CONSTRUCTION AND ELECTRICAL/LIGHTING.
B. See detail 4/A001 for typical installation alignment requirements for electrical devices.
C. Refer to Construction Floor Plans (A21 Series Sheets) for additional Miscellaneous Specialties
& Equipment items that may not be indicated on this sheet.
D. All dimensions are from finished wall surface or column centerline to centerline of outlets or
centerline of pairs of outlets.
E. All wall mounted wiring devices and receptacles shown back-to-back shall be offset a
minimum of 8" and acoustically sealed.
F. Where direct connection to prewired furniture panels occurs, provide power and
telecommunication feeds to indicated panel locations from wall, column or floor source
directly adjacent to this location.
G. All existing floor mounted electrical/telecommunication locations which are not reused are
to be removed. Remove all associated cable, wire and conduit back to the source.
Properly patch and repair affected wall, floor and/or ceiling construction.
H. Unless otherwise noted, all device elevations refer to centerline.
J. Refer to Reflected Ceiling Plans (A22 Series Sheets) for locations of light switches.
K. All outlets that are in the vicinity of any wet areas (kitchens, break rooms, restrooms, janitorial
rooms with floor sinks, laundry rooms, stand alone wall mounted sinks, electrical water
fountains, etc.) ground fault circuit interrupt (G.F.C.I.) type. See Electrical Legend.
L. Furniture will be provided by tenant and is shown for reference only.
M. If 50% or more of the total number of light fixtures or luminaires are replaced, provide lighting
and occupancy controls per 2015 IECC.
N. Provide emergency lighting as required by code.
KEYED NOTES - ELECTRICAL
E1 Core Drill final location TBD. Type of poke thru to be verified with tenant and furniture
requirements.
E2 Core to be drilled for future use. Cap opening and install carpet tile over.
E3 2 data drops
E4 POTS line
E5 Coordinate with tenant for location and height requirement for IT equipment.
E6 IT equipment installed overhead no less than 80" AFF. Contractor to provide designer
with options for installation.
E7 duplex only this location.
E8 Provide data drop in wall for future TV location. Cap off and keep concealed in
wall.
E9 Data to be provided for future conference use. Cap off and keep concealed in
floor.
MISC. SPECIALTIES & EQUIPMENT
Mark Item Make Model Comments Count
E1 Refrigerator TBD TBD TFCI 1
E2 Microwave TBD TBD TFCI 1
E3 Dishwasher TBD TBD TFCI - GC to provide 1/4"
copper line
1
E4 Copier TBD TBD TFCI 1
E5 Television TBD TBD TFCI 3
E6 Mini Fridge TBD TBD TFCI 1
E7 Coffee Maker TBD TBD TFCI 1
E8 Water Cooler TBD TBD TFCI, countertop model 1
TA20 Coat hook DOUG MOCKETT CH53 CPCI 17
SHEET NUMBER:
COPYRIGHT 2015 CARSON DESIGN ASSOCIATES
JOB NO.
DATE:
DRAWING TITLE:
STAMP:
ISSUE:
MIDWEST
SOUTHWEST
12301 Research Blvd
Bldg IV - Suite 130
Austin, TX 78759
Tel 512.977.0520 Fax 512.977.0384
www.carsondesign.com
9229 Delegates Row
Suite 250
Indianapolis, IN 46240
Tel 317.843.5979 Fax 317.843.5975
A231
I1720009
01.31.18
Electrical Location &
Equipment Plan
211 W. Main St., Carmel, IN 46032
Invesque, Inc.
Monon & Main
Suite 400
01.31.18
Construction Documents -
Addendum No.1 01.31.18
0'
1/8" = 1'-0"
8' 4' 8' 16'
PLAN
**NOTE: Tenant to provide cut-sheets for all tenant provided equipment for contractor coordination. Verify final locations
of equipment with tenant.
1
1 Addendum No. 1 12.28.17
02/26/18
Nick Mishler