HomeMy WebLinkAbout010 - A241 - Finish Plan and NotesDN
1
2
3
4
5
6
7
8
P1
A B C D E F G H
Office
403
WB1
P1
CPT2
Office
404
WB1
P1
CPT2
Office
405
WB1
P1
CPT2
Office
406
WB1
P1
CPT2
Office
407
WB1
P1
CPT2
Office
408
WB1
P1
CPT2
Office
409
WB1
P1
CPT2
Office
410
WB1
P1
CPT2
Lounge
411
WB1
PT1/PT2
LVT1
Office
412
WB1
P1
CPT2
Office
413
WB1
P1
CPT2
Conference
414
WB1
P1
CPT2
Open Office
415
WB1
P1/P3
CPT1/CPT2
Breakroom
401
WB1
PT2/PT3
LVT1
Corridor
421
WB1
P1/P2
CPT1
Wellness/Conference
417
WB1
P1
CPT1
Janitor
418
PT-1
IT / Storage
419
EX
P1
Shower
416
CBT1
PT1/CWT1
CFT1
Corridor
400
WB1
PT2
CPT1
Entrance
400
WB1
P1/P2
CPT1
90°
P3
P3
P2
P2
P2
P2
Storage
402
WB1
P1
CPT1
P4 P4
P4 P4
P4 P4
P4
P4
P4
P4
82°
F1
F1
F1
F1
1 1
P2
P2
F2
P4
1
P4
Indicates Finish Material.
Indicates Keynotes.
PT1
2
Indicates
finish material.
Arrows
indicate
extent of
finish.
Wall
Room name
101
Floor
Wall Base
PT1
CPT1 CPT2
1 FINISH 1/8" = 1'-0" PLAN
FINISH NOTES
1. General
A. REFER TO GENERAL NOTES AND REFERENCE SPECIFICATIONS ON A0 SERIES SHEETS FOR
SPECIFICATIONS REGARDING NEW CONSTRUCTION AND FINISHES.
B. Dimensions are taken from the face of masonry walls, column centerlines, finish face
of existing walls and/or stud face of new walls unless otherwise indicated.
C. Verify all critical dimensions within and/or related to the exisitng building dimensions
and conditions indicated by visual survey and/or information from existing drawings.
D. Field verify all dimensions indicated as either +/- or V.I.F. (Verify in field).
E. Refer to Finish Legend and finish plan for all required finish information.
F. Plans are not to be scaled for finish information or dimensions. Contact the
Architect/Designer for clarification of finish information or dimensions.
G. Provide finish materials with flame spread and smoke developed ratings per code
required limits, based on ASTM E-84 Test Method
2. Painting/Staining
A All metal doors to be painted PT1(semi-gloss finish), unless noted otherwise.
B All painted metal door frames to be painted PT1 (semi-gloss finish), unless noted
otherwise.
C Refer to Door Schedule and Details Sheet for Door information.
D Paint begins from wall edges and corners, unless otherwise noted.
E Metal stair railings, risers, and stringers to be primed with appropriate primer and
painted PT1 (semi-gloss finish), unless noted otherwise.
3. Furniture/Equipment
A Verify all existing equipment and furniture sizes.
B Existing furniture or equipment shown as dashed and/or not identified are not part of
this work and are to be supplied and installed by the owner/tenant.
4. Flooring
A All carpet shall be CP1, unless noted otherwise.
B All VCT shall be RF1, unless noted otherwise.
C All ceramic tile shall be CM1, unless noted otherwise.
D If applicable, floors in toilet and bathing rooms shall have a smooth, hard,
nonabsorbent surface that extends onto the adjacent wall surfaces at a minimum of
6" above finish floor.
E Grout joints on floor tile to be 1/8" width, unless otherwise noted. Grout joints on wall
tile to be 1/8" width unless otherwise noted. If manufacturers recommended
installation instructions differ from this contractor to notify designer of condition.
F Flooring contractor to submit floor seaming diagram to Architect/Designer for review
and approval.
G Sheet vinyl welding rods to be used on seams where two colors join. All other seams
to be chemically bonded. Welding rod color for sheet vinyl is to match unless
otherwise noted.
5. Ceilings/Walls
A All walls shall be painted P1, unless noted otherwise.
B All base shall be WB1, unless noted otherwise and is to be provided in rolled goods
format.
C All ceiling shall be CL1, unless noted otherwise.
D All vertical faces of bulkheads to be painted standard ceiling white, unless otherwise
noted.
E All under side of bulkheads to be painted standard ceiling white, unless otherwise
noted.
F Gypsum board ceilings to be painted standard ceiling white, unless otherwise noted.
G Existing typical ceiling height is _'-_". Contractor should verify all critical dimensions
when determining wall finish requirements.
KEYED NOTES - FINISHES
F1 Align floor pattern with outside face (open office side) of bulkhead above.
F2 Provide vertical metal U-channel here if needed to seperate paint colors. Verify in
the field and consult designer prior to installation.
F3
F4
F5
F6
F7
F8
F9
F10
SCHEDULE - FINISH LEGEND
Mark Description Manufacturer Pattern Model Comments Wall Base Finish
CFT1 Ceramic Floor Tile TBD TBD TBD To match Core & Shell building
standard
CL1 Acoustic Ceiling Tile 24 x 24 Armstrong White Cirrus Tegular 2'x2' Tile
CPT1 Carpet Tile J+J Flooring Group Terra Firma Modular 7958 Color: 2014 Badwater Installation Method: Ashlar
(24"x24")
WB1: Johnsonite Charcoal 4" Continous Cove - Vinyl
CPT2 Carpet Tile J+J Flooring Group Milky Way 7956 Color: 2014 Badwater Installation Method: Ashlar
(24"x24")
WB1: Johnsonite Charcoal 4" Continous Cove - Vinyl
CWT1 Ceramic Wall Tile Interceramic Wall Tile Collection Group 3 Bold Tones - Classic Navy 3"x6" tile; grout: Laticrete
Specktralock epoxy in color 60
Dusty Grey
CWT2 Ceramic Wall Tile TBD TBD TBD To match Core & Shell building
standard
GL1 Clear Tempered Glazing TBD N/A Clear Tempered Glazing
LVT1 Luxury Vinyl Tile Shaw Contract Flooring Solitude 0648V Color: Umber 48761 Stagger Installation method WB1: Johnsonite Charcoal 4" Continous Cove - Vinyl
P1 Generic Paint Sherwin Williams SW 7008 Alabaster Eggshell Finish WB1: Johnsonite Charcoal 4" Continous Cove - Vinyl
P2 Accent Paint Sherwin Williams SW 7066 Gray Matters Eggshell Finish WB1: Johnsonite Charcoal 4" Continous Cove - Vinyl
P3 Accent Paint Sherwin Williams SW 7615 Sea Serpent Eggshell Finish Paint exposed deck above P3 in
flat finish
P4 Dry Erase Paint MDC Clear Fuze Install over specified paint color
P5 Exposed Column Paint Sherwin Williams SW 7069 Grizzle Gray Gloss
PL1 Plastic Laminate Wilsonart D91-60 Slate Grey vertical panel at breakroom
island
QZ1
SS1 Solid Surface Wilsonart Soothing Grey 9116GS
WD1 Wood Wood Stain to match Armstrong
Woodworks Natural Variations
Walnut
FINISH KEY
SCHEDULE - FINISH PLAN ABBREVIATIONS
Category Key Name Comments on Finish
Ceramic CFT / CWT Anything requiring a setting bed and grout,
including stacked stone
Ceiling CL Acoustical, specialty and wood
Carpet CP Includes carpet base
Existing To Remain EX
Fabric FB Upholstery and window covering including leather
and vinyl
Glass GL Back Painted, filmed, patterned, fritted, textured
and mirrors
LVT LVT Luxury Vinyl Tile
Miscellaneous MA Covers items not covered in other categories
Not In Contract NIC
Plastic Laminate PL Any laminate applied to a substrate including
metal, plastic and wood
Paint PT Includes paint treatments like Zolotone
Quartz QZ
Solid Surface SS Corian, 3 Form, Silestone, Avonite, Compac
Verify In Field VIF
Wall Base WB All wall bases including rubber, vinyl, and wood-
excluding stone and carpet bases
Wood WD Real wood in all applications excluding base
Finish Legend Key XD Indicates finish to be determined
SHEET NUMBER:
COPYRIGHT 2015 CARSON DESIGN ASSOCIATES
JOB NO.
DATE:
DRAWING TITLE:
STAMP:
ISSUE:
MIDWEST
SOUTHWEST
12301 Research Blvd
Bldg IV - Suite 130
Austin, TX 78759
Tel 512.977.0520 Fax 512.977.0384
www.carsondesign.com
9229 Delegates Row
Suite 250
Indianapolis, IN 46240
Tel 317.843.5979 Fax 317.843.5975
A241
I1720009
01.31.18
Finish Plan and Notes
211 W. Main St., Carmel, IN 46032
Invesque, Inc.
Monon & Main
Suite 400
01.31.18
Construction Documents -
Addendum No.1 01.31.18
0'
1/8" = 1'-0"
8' 4' 8' 16'
PLAN
CARPET KEY LEGEND
1
1
1
1 Addendum No. 1 12.28.17
02/26/18
Nick Mishler