Loading...
HomeMy WebLinkAbout014 - A600 - Door Notes, Elevations, and Details5/8" G.W.B. 3 5/8" METAL STUDS DOOR (REFER TO DOOR SCHEDULE) HOLLOW METAL FRAME 2" 1/2" 1 3/4" 1 3/4" 5/8" G.W.B. 3 5/8" METAL STUDS DOOR (REFER TO DOOR SCHEDULE) HOLLOW METAL FRAME 2" 5 7/8" 1 3/4" 1 3/4" 1/2" 5/8" G.W.B. 1/4" TEMPERED GLASS TIMELY FRAME 3 5/8" METAL STUDS CONT. WOOD BLOCKING 1 1/2" 1/4" TEMPERED GLASS 5/8" G.W.B. ALUMINUM FRAME 3 5/8" METAL STUDS CONT. WOOD BLOCKING 1 1/2" 1/4" TEMPERED GLASS ALUMINUM FRAME CONT. WOOD BLOCKING CONCRETE FLOOR SLAB 3/8" 1 1/2" SHEET NUMBER: COPYRIGHT 2015 CARSON DESIGN ASSOCIATES JOB NO. DATE: DRAWING TITLE: STAMP: ISSUE: MIDWEST SOUTHWEST 12301 Research Blvd Bldg IV - Suite 130 Austin, TX 78759 Tel 512.977.0520 Fax 512.977.0384 www.carsondesign.com 9229 Delegates Row Suite 250 Indianapolis, IN 46240 Tel 317.843.5979 Fax 317.843.5975 A600 I1720009 01.31.18 Door Notes, Elevations, and Details 211 W. Main St., Carmel, IN 46032 Invesque, Inc. Monon & Main Suite 400 01.31.18 Construction Documents - Addendum No.1 01.31.18 1 DOOR 3" = 1'-0" DETAIL-TIMELY DOOR HEAD GENERAL NOTES - DOOR & HARDWARE 1 Door stops to be wall mounted baseboard stops unless otherwise noted in door schedule remarks. Provide blocking inside wall for all wall mounted stops. Install wall stop just above base. 2 All new and existing doors to receive building standard lever handles. 3 All existing doors to be repaired for any damaged, scratched or worn areas. 4 All office doors to receive (1) coat hook Mockett CH23 (equipment code TA20) or equal. All coat hooks to be mounted on center of door at 5'-0" a.f.f. 5 Egress doors shall be readily openable from the egress side without the use of a key, special knowledge or effort. In group A occupancies having an occupant load less than 300, and group B,M & S occupancies, the main exterior door(s) are permitted to be equipped with key operated locking devices or deadbolt from the egress side provided that the locking device is readily distinguishable as locked and a readily visible durable sign is posted on the egress side on or adjacent to the door stating "This door to remain unlocked when building is occupied". The sign shall be 1" high letters on a contrasting background. Refer to 2015 International Building Code Section 1010.1.9.3,2.2 (Verify with local building code requirements). 6 Hardware Specifications given communicate performace and design intent. Contractor shall coordinate hardware submittal to comply with all building standard styles, finishes and specifications. Substitutions may be allowed unless noted otherwise. 7 Contractor shall coordinate scope for all security devices, conduit, power and junction box requirements with security vendor. 8 All access-controlled egress doors shall comply with IBC 2015 Section 1010.1.9 and .9. Door hardware supplier shall verify compliance and recommend to Architect any modifications to the door hardware group as required. 9 Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 1010.1.9. (TAS 404.2.7). Operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground. 2 DOOR 3" = 1'-0" DETAIL-TIMELY DOOR JAMB 3 DOOR 3" = 1'-0" DETAIL-TIMELY GLASS HEAD 4 DOOR 3" = 1'-0" DETAIL-TIMELY GLASS JAMB 5 DOOR 3" = 1'-0" DETAIL-TIMELY SILL 117 1 Addendum No. 1 12.28. 1 1 1 1 02/26/18 Nick Mishler