HomeMy WebLinkAbout016 - P-410 - 04 PlumbingDN
DN
3
4
5
6
7
8
P1
F G
H
SK
SH-1 WH
3/4" DCW
1/2" DCW
1/2" DHW
3/4" DHW
1
-
---
3/4" DHW
3/4" DHW
2
3
4
5
6
7
8
P1
F G
H
1
2
3
5
4
2" V
2" S
2" V
2" S
2" V
-
---
4" V
4" S
2" V
2" S
2" S
EXISTING PIPING
2" V
2" V
SK
CONNECT SAN TO EXISTING SAN
SH-1
1/2" DCW
1/2" DHW
1/2" DHW 1/2" DCW
3/4" DHW
3/4" DCW
3/4" DCW
3/4" DHW
1/2" DCW
1/2" DHW
SK
SH-1
WH
ROUTE P&T TO EXISTING
MOPSINK
3/4" DHW
Scale
Date
Drawn By
Checked By
Project Number
Mechanical Constractors, INC.
9151 Ford Circle
Fishers, Indiana 46038-3000
Phone: (317) 841 - 7877
www.leach-russellmech.com
Leach and Russell
Genesis
Engineering Group
Indiana Office
1203 East St. Clair
St.,Suite B
Indianapolis, Indiana
(317) 46206 927-8307
genesis-
engineering.com
1/4" = 1'-0"
01/09/2018 10:33:42 AM
P - 410
04 Plumbing
Invesque Inc.
Monon & Main Suite 400
Checker
J. Kemp
01/04/2018
000
1/4" = 1'-0"
1
1 - Domestic Water
Plumbing Fixtures
SH-1 60" x 35" x 6" White Fiberglass Shower Base
Dalta
Diamond
R10000-UNBX Valve body, T11800 3- Setting Diverter Trim,
55013 Hand Shower w/ 69" hose, 50560 CRM Wall Elbow,and
T142338 Shower Trim Monitior 14 Series LAHARA
SK-1 Elkay DSE-23322-3 Dayton Sink DLB Bowl 8"Deep 3 Hole 20 ga
Dalta 9178-DST LF Delta Kitchen Faucet SGLE HDLE Pull Down Chrome
Insinkerator Badger V 1/2 HP DISP
WH AO Smith DEN-30D 9 KW 208V 3PH WTR HTR 34" H x 18" D 95#
1/4" = 1'-0"
2
1 - Sanitary and Vent
3
Sanitary Vent
4
Domestic Water
No. Description Date
PLAN NOTES
1. EXISTING SANITARY VENT PIPING
2. TIE NEW SANITAR VENT INTO EXISTING SANITARY VENT
3. ROUTE SANITARY TO EXISTING SANITARY WC CARRIER
4. TIE NEW SANITARY VENT INTO EXISTING 4" VENT RISER
5. TIE NEW SANITARY INTO EXISTING 4" SANITARY RISER
PLAN NOTES
1. TIE NEW DOMESTIC COLD INTO EXISTING DOMESTIC WATER
2. ROUTE P&T TO EXISTING MOPSINK
1 State Submittal 1/8/18
02/26/18
Nick Mishler