Loading...
HomeMy WebLinkAbout019 - SM-01 - Build Area Duct PlanRA RB RC RD RE RF RG RA RB RC RD RE RF RG R1 R4 R6 R8 PLAN NOTES GRILLES, REGISTERS, AND DIFFUSERS SYMBOL MANUFACTURER/MODEL MATERIAL & TYPE MAX CFM NOM SIZE NECK SIZE NC REMARKS SD1 METALAIRE STEEL 115 24x24 6" 15 3 5750 SQUARE PLAQUE FACE SD2 METALAIRE STEEL 225 24x24 8" 16 3 5750 SQUARE PLAQUE FACE SD3 METALAIRE STEEL 375 24x24 10" 20 3 5750 SQUARE PLAQUE FACE SD4 METALAIRE STEEL 225 24x24 8" 20 1,3 5750 SQUARE PLAQUE FACE SG1 METALAIRE ALUMINUM 225 14X8 12X6 18 4 4002PCF SPIRAL DUCT GRILLE RG1 METALAIRE ALUMINUM N/A 24X12 22X10 N/A 2 CC45 EGGCRATE RETURN RG2 METALAIRE ALUMINUM N/A 24X24 22X22 N/A 2 CC45 EGGCRATE RETURN EG1 METALAIRE STEEL 100 8X8 6X6 14 4 RH LOUVER FACE 11/16", SINGLE, 45 DEG SL1 METALAIRE STEEL 210 4"x48" 8" 18 5 6610 [2] 1" SLOT SLOT DIFFUSER SCHEDULE REMARKS EXHAUST FAN SCHEDULE UNIT TAG EF-1 SERVES IT CLOSET MANUFACTURER PANASONIC MODEL FV-08-11VF5 ELEC PH-HZ 120/60 DISCONNECT MFR. FAN CFM 80 STATIC PRESSURE 0.1 NOTES NOTES 1 1. FAN ON/OFF WITH THERMOSTAT SM-01 MECHANICAL CONTRACTOR: CONSTRUCTION NOT INDICATED HEREIN WILL IN NO WAY BE PERMITTED OR CONVEY ADDED SPECIFIED AND THAT ANY USE OF THESE DESIGNS, EITHER IN WHOLE OR IN PART, FOR OTHER IT IS THE INTENT OF THIS CONTRACTOR THAT THESE DRAWINGS BE USED ONLY FOR THE PROJECT INTENT OR RESPONSIBILITY BY METAL MASTERS INC. NO. DRAWING ISSUED DESCRIPTION DATE 1 STATE SUBMITTAL 01-05-18 DRAWN BY: DRAWING OF: SCALE: J. GULDI 1/4" = 1'-0" BUILDING / AREA DUCT PLAN Leech & Russel 2514 East Bethel Avenue, Indianapolis, IN 46203 Phone (317)780-1864 Fax (317)780-7968 FLEXIBLE DUCT AND NECK SIZE DIFFUSER/GRILLE TYPE - CFM TOP & BOTTOM DUCT ELEVATION TRANSITION FLAT ON TOP SYMBOL LEGEND 90° ELBOW W/TURNING VANES ACCESS DOOR IN DUCT FIRE DAMPER VOLUME DAMPER EXHAUST AIR GRILLE RETURN AIR GRILLE SUPPLY AIR DIFFUSER FOT TOD = BOD = SD - 300 12 Ø FOB TRANSITION FLAT ON LEFT FD M MOTORIZED DAMPER VD W x H L(x) DUCT SIZE AND LENGTH W x H DUCT SIZE AND LENGTH L(x) W x H L(x) LINED DUCT SIZE AND LENGTH DIMENSIONS ARE O.D. DUCT SIZE FLEXIBLE CONNECTION GENERAL NOTES 1. ALL DUCTWORK TO BE FABRICATED AND INSTALLED PER S.M.A.C.N.A. STANDARDS, PROJECT SPECIFICATIONS, ADDENDUMS, AND SHOP STANDARDS SUBMITTAL PER THIS PROJECT. 2. ALL DUCT ELEVATIONS ARE FROM FINISHED FLOOR 0'-0" UNLESS NOTED ON DRAWINGS. 3. ALL DUCT DIMENSIONS ARE NOTED AS OUTSIDE DIMENSIONS. 4. ALL SQUARE 90° ELBOWS AND TEES TO HAVE TURNING VANES. 5. ALL SQUARE 90° ELBOWS AND TEES ARE 6" THROATS UNLESS NOTED ON DRAWINGS. 6. ALL RADIUS 90° ELBOWS ARE 1 1 2 (x) AT CENTERLINE UNLESS NOTED ON DRAWINGS. 7. VERIFY LOCATION AND ELEVATION OF DUCT, ARRANGEMENT OF GRD's, EQUIPMENT AND ACCESS DOORS AFTER COORDINATION WITH OTHER TRADES. Job # 7484 1 STATE SUBMITTAL 01-08-18 02/26/18 Nick Mishler