Loading...
HomeMy WebLinkAbout020 - E000 - Electrical Notes, Symbols & ScheduleDate Drawn By Checked By Project Number REVISIONS 1. 2. 3. 4. 5. ERMCO, Inc. 1625 W. Thompson Rd. P.O. Box 1507 Indianapolis, IN 46206-1507 (317) 780-2923 www.ermco.com All rights reserved. 1/10/2018 1:01:53 PM E000 ELECTRICAL NOTES, SYMBOLS & SCHEDULE MONON & MAIN SUITE 400 211 W. Main St., Carmel, IN 46032 INVESQUE, INC MAH JEP 01-08-18 Project Number 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED LABOR, MATERIAL, EQUIPMENT AND SERVICES NECESSARY TO COMPLETE THE INSTALLATION OF ALL SYSTEMS INDICATED. THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL ITEMS REQUIRED FOR A FULLY FUNCTIONING SYSTEM. 2. ALL MATERIALS AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY RECOGNIZED CODES AND STANDARDS. 3. DO NOT LOCATE BOXES BACK TO BACK IN WALL PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE SOUND TRANSMISSION. 4. COORDINATE THE SERVICE INSTALLATION WITH THE UTILITY COMPANY. INSTALL METER CABINET PROVIDED BY THE UTILITY COMPANY IN ACCORDANCE WITH THE UTILITY COMPANY'S STANDARDS. 5. PROVIDE ALL GROUNDING AS REQUIRED TO MEET THE UTILITY AND NEC SECTION 250 REQUIREMENTS. 6. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED AND LABELED. 7. ALL EQUIPMENT AND DEVICES SHALL BE INSTALLED IN A PROFESSIONAL AND WORKMANSHIP MANNER AND IN COMPLIANCE WITH NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION (NECA) RECOMMENDED STANDARDS. 8. MATERIALS SHALL BE RECEIVED AND STORED IN A MANNER TO BEST PROTECT THE MATERIALS PRIOR TO INSTALLATION. PROTECTIVE COVERS SHALL REMAIN IN PLACE AS MUCH AS POSSIBLE. 9. HANGERS AND SUPPORTS SHALL BE USED AS REQUIRED TO PROPERLY AND FULLY SUPPORT ALL ELECTRICAL MATERIALS AND EQUIPMENT IN A PERMANENT MANNER. 10. ALL MATERIALS AND EQUIPMENT USED SHALL BE OF THE TYPE DESIGNED AND SUITABLE FOR THE MANNER IN WHICH THEY ARE INSTALLED. 11. EQUIPMENT SHALL BE INSTALLED LEVEL, PLUMB AND TRUE WITH THE STRUCTURE AND OTHER EQUIPMENT AND INSTALLED IN A HORIZONTAL OR VERTICAL POSITION AS INTENDED. 12. ROUTE RACEWAYS PARALLEL OR PERPENDICULAR TO BUILDING SURFACES OR EXPOSED STRUCTURAL MEMBERS AND FOLLOW SURFACE CONTOURS IN ORDER TO PRESENT A NEAT APPEARANCE. 13. GROUP RACEWAYS WHERE POSSIBLE AND COMPLY WITH RECOMMENDED SPACING STANDARDS. 14. BENDS AND OFFSETS IN PARALLEL RACEWAYS SHALL BE MADE FROM THE SAME CENTER LINE SO THE BENDS AND OFFSETS REMAIN PARALLEL. 15. TAKE ALL NECESSARY PRECAUTIONS TO PREVENT FOREIGN MATTER FROM ENTERING RACEWAYS. IF NECESSARY, CLEAN OUT RACEWAYS PRIOR TO PULLING IN THE CONDUCTORS. 16. ALL WIRE AND CABLE SHALL BE SUITABLE FOR THE TEMPERATURE, CONDITIONS, AND LOCATIONS WHERE THEY ARE INSTALLED. 17. TAKE ALL NECESSARY PRECAUTIONS WHEN PULLING WIRE AND CABLES TO PREVENT DAMAGE TO THE INSULATION. 18. ALL CONDUCTORS TO BE PULLED IN A RACEWAY SHALL BE PULLED TOGETHER. 19. KEEP CONDUCTOR SPLICES TO A MINIMUM. 20. TYPICAL DEVICE MOUNTING HEIGHTS (ABOVE THE FINISHED FLOOR TO THE CENTER OF BOX) ARE AS FOLLOWS: a. WALL SWITCHES 48” b.RECEPTACLES 18” c.COUNTERTOP RECEPTACLES 42” OR 6” ABOVE THE COUNTERTOP d.DISCONNECTS 72” TO THE TOP OF THE HANDLE e.PANELBOARDS 72” TO THE TOP f. TELECOM OUTLETS 18” g.THERMOSTATS 54” h.PULL STATIONS 48” I. VISUAL STROBES 80” GENERAL NOTES ELECTRICAL SHEET INDEX E000 ELECTRICAL NOTES, SYMBOLS, AND SCHEDULES E101 LIGHTING PLAN E201 POWER AND SYSTEMS PLAN E500 ELECTRICAL PANEL SCHEDULES LABELING AND IDENTIFICATION: • PROVIDE NAME PLATE LABEL (IDENTIFICATION) TO SERVICE EQUIPMENT, PANELBOARDS, DISCONNECT SWITCHES AND SIMILAR EQUIPMENT. • PROVIDE LABEL TO IDENTIFY CIRCUIT NUMBER AT JUNCTION BOXES AND DEVICE BOXES USING BLACK MARKER. RACEWAYS: • EMT, MINIMUM 3/4" CONDUIT, COMPRESSION FITTING, USE FOR EQUIPMENT CONNECTION, FEEDERS AND BRANCH CIRCUITS. USE PVC40 FOR OUTDOOR UNDERGROUND INSTALLATIONS. SUPPORT: • EMT CONDUIT: CONDUIT STRAP 3 FEET FROM END AND AT EVERY 10 FEET. CONDUCTORS: • 600VOLTS, 98% CONDUCTIVITY, COPPER, CLASS B, THHN/THWN INSULATION, MINIMUM #12AWG. USE EMT CONDUITS FOR #8AWG AND LARGER. WIRING DEVICES: • RECEPTACLES: (NEMA 5-20R), DUPLEX, 20 AMP, 125 VAC, GROUNDING TYPE, WHITE COLOR, HUBBELL 5352 OR EQUAL. MOUNT AT 18" A.F.F. UNLESS OTHERWISE NOTED. • GFCI TYPE RECEPTACLE: (NEMA 5-20RGFI), DUPLEX, 20 AMP, 125 VAC, DUPLEX 5 ML AMP SENSITIVITY TRIP TYPE, HUBBELL GF-5362 OR EQUAL. MOUNT AT 18" A.F.F. UNLESS OTHERWISE NOTED. • OCCUPANCY SENSORS (WALL MOUNTED): REFER TO DRAWINGS FOR MODEL NUMBER. MOUNT AT 48" A.F.F. UNLESS NOTED OTHERWISE. • COVERPLATES: OFFICE: NYLON SCRATCH PROOF DOCK: STAINLESS STEEL • WEATHERPROOF: BELL BOX WITH WEATHERPROOF COVER. MOTOR STARTERS: • MANUAL STARTER SHALL BE HORSEPOWER RATED, THERMAL OVERLOAD TYPE WITH PILOT LIGHT. MOUNT AT +72" A.F.F. TO TOP. SQUARE D 2500 OR EQUAL. DISCONNECT SWITCHES: • HEAVY DUTY TYPE, FUSIBLE OR NON FUSIBLE AS INDICATED ON DRAWINGS, QUICK-MAKE QUICK-BREAK TYPE, HINGE LOCKABLE COVER, OPERATING LEVER. MOUNTING AT +72" A.F.F. TO TOP. SQUARE D HEAVY DUTY OR EQUAL. SPECIFICATIONS GROUNDING: • GROUNDING SYSTEM SHALL MEET REQUIREMENTS OF NEC ARTICLE 250. BOND WATER PIPE, BUILDING STRUCTURE, AND 25' OF BARE COPPER WIRE, COPPER CLAD GROUND ROD 3/4"D x 10'L, AND CONNECT WITH #2/0 AWG BARE COPPER CABLE TO MAIN SERVICE DISTRIBUTION BUS. PROVIDE A SEPARATE GROUND WIRE WITH EVERY BRANCH CIRCUIT. TEST IN ACCORDANCE WITH NEC ARTICLE 250. • PROVIDE AN INTERSYSTEM BONDING TERMINATION FOR THE TELECOMMUNICATIONS HEAD END EQUIPMENT AND BOND TO THE ELECTRICAL GROUNDING ELECTRODE SYSTEM STEP DOWN TRANSFORMER: • TRANSFORMER HOUSING SHALL BE ENCLOSED IN VENTILATED, DRIP-PROOF CODE GAUGE STEEL HOUSING, REMOVABLE ACCESS PANELS, RODENT BARRIERS ON OPENING, PHOSPHATIZED, AND FINISH WITH CORROSION INHIBITING UNDERCOAT AND ANSI GRAY FINISH. • CORE AND COIL ASSEMBLY SHALL BE CONSTRUCTED OF CONTINUOUS COPPER WINDING, HIGH GRADE, NON-AGING, GRAIN ORIENTED SILICON STEEL CORE, COMPLETELY ISOLATED FROM THE ENCLOSURE USING VIBRATION ABSORBING MOUNT,FLEXIBLE GROUNDING STRAP. • TWO 2-1/2% FCAN AND FOUR 2-1/2% FCBN TAPS. • INSULATION SHALL BE 600VAC, DRY TYPE, AIR COOLED, 220°C TEMPERATURE CLASS 150°C. • NOISE LEVEL SHALL BE LESS THAN ANSI STANDARD. • DRY TYPE TRANSFORMER SHALL BE SIMILAR TO SQUARE D WATCH DOG SERIES OR EQUAL. SERVICE PANELBOARD: • MAIN BUS, NEUTRAL AND GROUND BAR SHALL BE COPPER, NEMA-1 CABINET, GRAY PAINT, NAME PLATE, U.L. LISTED. LISTED TO USE AS SERVICE ENTRANCE. SIMILAR TO SQUARE D NQOD OR EQUAL. BRANCH CIRCUIT PANELBOARD: • MAIN BUS, NEUTRAL BUS, AND GROUND BAR, SHALL BE COPPER, NEMA-1 CABINET, GRAY PAINT, NAME PLATE, BOLT-ON BREAKERS, DOOR AND TRIM WITH DOOR-IN-DOOR CONSTRUCTION, U.L. LISTED. PANEL DIRECTORY. SIMILAR TO SQUARE D NQOD OR EQUAL. LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER DESCRIPTION LAMP INPUT WATTS NOTES D1 ALPHABET NU4 RD RECESSED DOWNLIGHT LED 32 W OR EQUAL D2 ALPHABET BETA4 PENDANT LED 34 W OR EQUAL D3 ALPHABET NU4 RD RECESSED DOWNLIGHT LED 32 W MATCH EXISTING EX TBD TBD EXIT LIGHT LED 4 W MATCH EXISTING F1 FINELITE HP-2D DIRECT LINEAR LED 28 W OR EQUAL F1.1 FINELITE HP-2 WW LINEAR WALLWASH LED 28 W OR EQUAL K1 COLUMBIA LIGHTING LCAT22 2'x2' TROFFER LED 32 W OR EQUAL K2 COLUMBIA LIGHTING LCAT22 2'x2' TROFFER WITH ELL14 EMERGENCY BATTERY PACK LED 32 W OR EQUAL P1 LSI TBD DEEP BOWL ALUMINUM REFLECTOR LED 75 W OR EQUAL POWER AND SYSTEMS SYMBOL FIRE ALARM SYMBOL SCHEDULE LIGHTING SYMBOL SCHEDULE SCHEDULE SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION PLAN NOTE ELECTRICAL PANEL DUPLEX RECEPTACLE, 16" AFF (TYP) DUPLEX RECEPTACLE, GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, GROUND FAULT INTERRUPTER, WEATHERPROOF, WITH "WHILE-IN-USE" COVER DOUBLE DUPLEX RECEPTACLE SPECIALTY RECEPTACLE FLOORBOX FLOOR POKE THRU TELECOMMUNICATIONS OUTLET PHONE OUTLET, WALL MOUNTED AT 48" TV CABLE OUTLET PUSHBUTTON START/STOP STATION JUNCTION BOX, WALL MOUNTED JUNCTION BOX, CEILING MOUNTED MOTOR DISCONNECT SWITCH, NF = NON-FUSED 4'X8' PLYWOOD TELEPHONE BACKBOARD SPEAKER CEILING MOUNTED POKE THRU - 4" CORE FURNITURE FEED - 2" CORE CARD READER MOTION SENSOR REQUEST TO EXIT NOTE: ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON THE PROJECT. NOTE: ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON THE PROJECT. NOTE: ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON THE PROJECT. MANUAL PULL STATION, 48" AFF (TYP) SMOKE DETECTOR SMOKE DETECTOR-DUCT MTD HEAT DETECTOR TAMPER SWITCH FLOW SWITCH HORN/STROBE NOTIFICATION DEVICE, 80" AFF (TYP) STROBE ONLY NOTIFICATION DEVICE SPEAKER NOTIFICATION DEVICE FIRE ALARM CONTROL PANEL FIRE ALARM REMOTE ANNUNCIATOR SWITCH, a = SWITCH LEG, 48" AFF (TYP) 3-WAY SWITCH SLIDE DIMMER SWITCH OCCUPANCY SENSOR SWITCH, WALL MOUNTED PHOTOCELL TIME CLOCK 2' x 4' LIGHT FIXTURE - XX DENOTES TYPE, a SIGNIFIES SWITCH LEG, # DENOTES CIRCUIT EMERGENCY BATTERY PACK EXIT SIGN, WALL MOUNTED EXIT SIGN , CEILING MOUNTED EXTERIOR WALL PACK PENDANT LIGHT FIXTURE TIMER SWITCH NIGHT LIGHT HORN/STROBE NOTIFICATION DEVICE, WEATHERPROOF OCCUPANCY SENSOR SWITCH, CEILING MOUNTED # GFI GFI WP TV J J W NF S F FF CR MS REX F S S H TS FS D F F V WP S FARA FACP OC PC TC S a 3 D OC a xx # T NL BACK BOX ROUGH-IN W/ EMPTY 1" CONDUIT EXTENDED 6" ABOVE CEILING AND PULL-STRING S S S S FF FURNITURE FEED - WALL S HORN/STROBE - CEILING F S STROBE ONLY - CEILING F FLOORBOX SCHEDULE MODEL MANUFACTURER DESCRIPTION SIZE 4FF WIREMOLD FLUSH POKE-THRU FURNITURE FEED 4" 6AT WIREMOLD FLUSH POKE-THRU 6" RC3 WIREMOLD FLUSH POKE-THRU 4" JAMES EDWARD POTTS 01/08/2018 CERTIFIED BY DATE 02/26/18 Nick Mishler