HomeMy WebLinkAbout18020131 Building PlansRELEASE 10. HLL UUUR rlMIV ULr-3 3rlHLL Dr- Ur I rlC Lr-VCR I irr-, rlHRU VV HRC 3rlHLL Dr- I V I U U IV I CU IVU rl1 UrICR I rlMIV 40 HDUVr- r1IV 13 rl r L U U rC. 19. ALLACCESS PANELS SHALLBE 24"X30" UNLESS OTHERWISE NOTED. 20. ALLGLASS UNITS LOCATED IN HAZARDOUS LOCATIONS AS INDICATED IN IBC 2406.3 SHALLCOMPLY WITH TEST REQUIREMENTS OF CONSUMER PRODUCT SAFETY COMMISSION 16, CFR PART 1201 FOR HUMAN IMPACT LOADS. 21. ALLSAW CUTTING AND CORING LOCATIONS SHALLBE REVIEWED IN FIELD BYTHE GENERALCONTRACTOR PRIOR TO CUTTING/CORING. 22. ALLWOOD IS TO BE FIRE -RETARDANT TREATED PER AWPA C20 AND C27 AND SHALLNOT HAVE A FLAME SPREAD OF GREATER THAN 25 WHEN TESTED IN ACCORDANCE WITH ASTM E-84. PER IBC SECTION 2303.2. S.F. / OCCUPANT EGRESS EXITS EXITS EGRESS USE AREA PERSON LOAD REQUIRED REQUIRED PROVIDED WIDTH O.L. X .20 = PROVIDED IBCTABLE IBC 1005.1 IBCTABLE 1004.1.1 1021.1 M USE GROUP 743 SQ. FT. 30 25 36" 1 1 36" SPACEF30A 26 FIREBLOCKING SHALLBE INSTALLED AT ALLINTERCONNECTIONS BETWEEN VERTICALAND HORIZONTALSPACES SUCH AS OCCUR AT SOFFITS OVER GR ESS: 23. ALLEXTERIOR WOOD BLOCKING IS TO BE PRESSURE TREATED PER AWPA U1 AND M4. REQ'D PROVIDED 24. ALL FASTENERS, CONNECTORS, OR OTHER HARDWARE IN DIRECT CONTACT WITH PRESERVATIVE TREATED OR FIRE RETARDANT TREATED WOOD SHALL EGRESS WIDTH (OCC LOAD x .2") = 25 x .2" = 5" 36" IBC SECTION 1005.1 BE STAINLESS STEELTYPE 304 OR TYPE 316, OR HOT -DIPPED GALVANIZED STEELASTM A653, CLASS G-185 WITH 1.85 OUNCES OF ZINC PER SQUARE FOOTTO REDUCE THE CORROSION PROCESS. NUMBER OF EXITS: 1 1 IBC SECTION 1021.2 EXIT ACCESS TRAVELDISTANCE: 250'-0" 35'-11" IBC TABLE 1016.1 25. FIREBLOCKING SHALLBE INSTALLED IN CONCEALED SPACES OF STUD WALLAND PARTITIONS, INCLUDING FURRED OR STUDDED -OFF SPACES OF COMMON PATH OF TRAVEL: 75'-0" 11'-6" IBC SECTION 1014.3 MASONRY OR CONCRETE WALLS, AND AT THE CEILING AND FLOOR OR ROOF LEVELS. PER IBC SECTION 717.2.2. PLUMBING FIXTURES PROVIDED: IBC TABLE 2902.1 CABINETS, DROP CEILINGS, COVE CEILINGS AND SIMILAR LOCATIONS. PER IBC SECTION 717.2.3. 27. REQUIRED FLAME SPREAD RATING: INTERIOR FINISH OF WALLS AND CEILINGS SHALLHAVE A FLAME SPREAD RATING NOT GREATER THAN THAT DESIGNATED BYTHE CLASS PRESCRIBED FOR THE VARIOUS GROUPS LISTED IN IBC TABLE 803.5, WHEN TESTED IN ACCORDANCE WITH IBC SECTION 803.2. 28. PROVIDE PORTABLE FIRE EXTINGUISHERS WITH U.L. LABELAND A RATING OF NOT LESS THAN 4A 80B:C WITH 75 FT TRAVELDISTANCE TO ALL POSITIONS OF BUILDING OR AS DIRECTED BYTHE FIRE DEPARTMENT FIELD INSPECTOR. WATER CLOSET/URINALS LAVATORIES MS USE OCC. CALC. MALE/FEMALE CALC. MALE/FEMALE 1 OCCUPANT LOAD M 25 1:50 .25/.25 1:80 .15/.15 REQUIRED NUMBER OF FIXTURES .25/.25 .15/.15 1 NUMBER OF FIXTURES PROVIDED 1 1 1 AREA OF WORK ACCESSIBILITY INFORMATION SITE LOCATION MAP PROJECT TEAM 1. ACCESS TO THESE FACILITIES SHALLBE PROVIDED AT PRIMARY ENTRANCES. PROJECT OWNER ARCHITECT MEP ENGINEER 2. THE SLOPE OF PUBLIC WALKS SHALLNOT EXCEED MAX. CROSS SLOPE 2 %. Washington Prime Group red architecture + planning red architecture + planning 3. WALKING SURFACES SLOPING GREATER THAN 2 % SHALLBE SLIP RESISTANT. 4. PROVIDE A 60" x 60" MIN. LANDING ON STRIKE SIDE OF DOOR WITH 44" MINIMUM WIDTH IN DIRECTION OF TRAVEL. PROJECT LOCATION 180 East Broad Street Colu mbu s,Ohio 43215 855 Grandview Ave, Suite295 Colu mbu s,Ohio 43215 855 Grandview Ave, Suite295 Colu mbu s,Ohio 43215 5. WALKS SHALLEXTEND 24 TOTHE SIDE OF THE STRIKE EDGE OF DOOR OR GATE T HAT SWINGS TOWARD THE WALK. P:614.887.5664 P:614.487.8770 P:614.487.8770 6. EVERY REQUIRED EXIT DOORWAY SHALLBE SIZED FOR A DOOR NOT LESS THAN 3'-0" WIDE BY 6'-8" HIGH CAPABLE OF OPENING 90 DEGREES AND CONTACT: Chad Biniker F: 614.487.8777 CONTACT: Stephan Sahayda F:614.487.8777 CONTACT: DougSmelker MOUNTED SO THATTHE CLEAR WIDTH OF THE EXIT SHALLBE A MINIMUM OF 32". 7. THRESHOLDS TO BE A MAXIMUM OF i"ABOVE THE ADJACENT FINISHED FLOOR. CONTRACTOR 8. MAXIMUM EFFORT TO OPERATE DOORS SHALLNOT EXCEED 5 LBS FOR INTERIOR DOORS AND 15 LBS FOR EXTERIOR DOORS. 9. THE BOTTOM 10" OF ALLDOORS EXCEPT AUTOMATIC SLIDERS SHALLHAVE A SMOOTH UNINTERRUPTED SURFACE. TBD 10. THE BUILDING SHALLCOMPLY WITH THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) AND ANSI A117.1-2009, INCLUDING BUT NOT LIMITED TO IBC CHAPTER 11. 11. CONTROLS AND OPERATING MECHANISMS SHALLBE ACCESSIBLE AND HAVE MOUNTING HEIGHTS COMPLYING WITH ANSI 4.27. RIFE CNN RULjIbhROOM, DIRECTIONAL, AND INFORMATION SIGNS SHALLBE ACCESSIBLE DESIGN COMPLYING WITH ANSI 4.13 AND 4.30. Suubjeatto morepdG of State andLocal Codes 0tp of Camal DATE: 03/07/18 Nick Mishler • • un Ln O n ra r-1 rr_ n ra N N � r- (3) M 00 00 • .� 00 00 > •- �O ra ' Lr)Ln C (6 00 Z3 0 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. v z w Ln W N > 0 nro = 0 1 Z) 0 00 C^ L Z)0 J Q zmo J N m (DW Q LU LU J Q � Q z �o () O Wa z o Q �m M>_z a w U J LU z~ cn U � � V) w m Q O Q 0 (� rl U Li �: r-I PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 SHEET: COVER SHEET Celili z_ 18" MIN. FRONT APPROACH, PULLSIDE FIGURE 404.2.3.2 (a) RECESSED DOOR FRONT APPROACH, PUSH SIDE FIGURE 404.2.3.5 (b) NOTE - Y = 48" IF DOOR HAS BOTH A CLOSER AND LATCH z c.l 22" MIN. u HINGE APPROACH, PUSH SIDE FIGURE 404.2.3.2 (e) a rn 00 RELEASED IFCR CONSTRUCH Suubjeul to aumpliamce with all regulatimms at State and Ilocal Endles IC'Itp u Caimal ntro DATE: 03/07/18 Nick Mishler I- � II z 0 18" MIN. 00 x RECESSED DOOR FRONT APPROACH, PULLSIDE FIGURE 404.2.3.5 (a) z 00 ^ 12" MIN.00 � In RECESSED DOOR FRONT APPROACH, PUSH SIDE WITH BOTH CLOSER AND LATCH FIGURE 404.2.3.2 (c) NOTE - Y = 54" IF DOOR HAS A CLOSER BO 24" MIN. LATCH APPROACH, PULLSIDE FIGURE 404.2.3.2 (f) i z II � li I� z 00 X = 22" MIN. POCKET/ FOLDING DOOR POCKET/ FOLDING DOOR FRONT APPROACH POCKET OR HINGE APPROACH FIGURE 404.2.3.3 (a) FIGURE 404.2.3.3 (b) WITHOUT DOOR WITHOUT DOOR FRONT APPROACH SIDE APPOACH FIGURE 404.2.3.4 (a) FIGURE 404.2.3.4 (b) NOTE : X = 12" IF DOOR HAS BOTH A CLOSER AND LATCH z_ 00 FRONT APPROACH, PUSH SIDE FIGURE 404.2.3.2 (b) 42" } NOTE- X = 36" MIN. IF Y = 60" X=42" IFY=54" HINGE APPROACH, PULLSIDE FIGURE 404.2.3.2 (c & d) NOTE - Y = 48" IF DOOR HAS A CLOSER cz_ G 24' I N u L } LATCH APPROACH, PUSH SIDE FIGURE 404.2.3.2 (9) z I X=24" MIN. J POCKET / FOLDING DOOR STOP OR LATCH APPROACH FIGURE 404.2.3.3 (c) MANEUVERING CLEARANCES AT DOORS 1/4" = 1'-0" x a 2 1� a x a FIGURE 303.2 FIGURE 303.3 VERTICALCHANGE IN LEVEL BEVELED CHANGE IN LEVEL CHANGES IN LEVEL N.T.S. 12" MIN. 36" MIN. 12" MIN. 10 10 N z_ 60" MIN. m CIRCULAR T-SHAPED FIGURE 304.3 (a) FIGURE 304.3 (b) WHEELCHAIR TURNING 1/4" = 1'-0" 37" MIN_ HINGED DOOR FIGURE 404.2.2 (a) 32� Cl 32" MIN. 1 FOLDING DOOR FIGURE 404.2.2 (c) CLEAR DOO RWA 1/4" = 1'-0" X a in 2 0 10" MA)qLl .1 UNOBSTRUCTED SIDE REACH FIGURE 308.3.1 -9--� SIDE REACH 4" MAX. I I OF n' x o 11 x N 12" MAX. 12" MAX. a n N x n N FIGURE 307.2 FIGURE 307.3 LIMITS OF PROTRUDING OBJECTS POST -MOUNTED PROTRUDING OBJECTS PROTRUDING OBJECTS 1/4" = 1'-0" 1pm m m m 42" MIN. 42" MIN. 36" MIN. 36" MIN. 24" MA 48" MIN. 24" MAX. X < 48" X < 48" 180 DEGREE TURN 180 DEGREE TURN (EXCEPTION) FIGURE 403.5 FIGURE 403.5.1 CLEAR WIDTH AT 180 DEGREE TURN r5--� CLEAR WIDTH OF AN ACCESSIBLE ROUTE SLIDING DOOR FIGURE 404.2.2 (b) 36" MIN. MO N DOORWAYS WITHOUT DOORS FIGURE 404.2.2 (d) YWIDTH &DEPTH a � a a 2 0 1.0 m 10" MAX 10" - 24" MAX. UNOBSTRUCTED HIGH SIDE REACH FIGURE 308.3.2 (a) 1/4" = 1'-0" 0 Of O O — 0 � z 00 0 0 FIGURE 404.2.5 (a) FIGURE 404.2.5 (b) FIGURE 404.2.5 (c) TWO HINGED DOORS IN SERIES 1/4" = 1'-0" 48" MIN. 2 L _ UNOBSTRUCTED FORWARD REACH FIGURE 308.2.1 10 FO RWA X a 2 00 UNOBSTRUCTED HIGH FORWARD REACH FIGURE 308.2.2 (a) RD REACH > 20"-25" M AREA OF REFUGE ARE RFF OF \ G �\ z a ARIES 2 - SEE FIGURE 00 � 12/A0.2 TACTILE CHARACTERS Of Lu z w U F- Z C� VARIES - COORD: IN FIELD cZ 4 G CLEAR FLOOR SPACE, 18 MIN. CENTERED ON TACTILE CHARACTERS ARC OF DOOR SWING FIGURE 703.3.10 FIGURE 703.3.11 HEIGHT OF RAISED CHARACTERS LOCATION OF SIGNS AT DOORS ABOVE FLOOR COMMUNICATION ELEMENTS AND FEATURES 1/4" = 1'-0" 91, EDGE OF DOOR FRAME O O z_ - y �\ to RESTROOM FAMILY MEN STAIRS 11/2" HIGH WHITE LETTERING ON BLACKBACKGROUND z_ 0 WOMEN PROVIDE (1) SIGN PER TOILET COMPLYING WITH ANSI 2009, SECTION 703. SIGN TO HAVE RAISED AND BRAILLE CHARACTERS AND PICTORIALSYMBOL OF ACCESSIBILITY. MOUNT 5'-0" TO CENTERLINE A.F.F. BLACKPLASTIC (FIELD) 74M. BACKGROUND w/ WHITE RAISED OR DEPRESSED EMBLEMS (NOTE- EMBLEMS & LETTERING MUST BE RAISED OR UNOBSTRUCTED HIGH DEPRESSED MIN. 1/32" TYPICAL) FORWARD REACH FIGURE 308.2.2 (b) 1/4" = 1'-0" G0.1 1/4" = 1'-0" 48" MIN. N � n n v__ x x ri z_ z z 0 0 0 CD o 13� 00 M, % X > 24" , 36" MIN. , 60" MIN. CLEARFLOORSPACE FORWARD APPROACH PARALLELAPPROACH FORWARD APPROACH PARALLELAPPROACH FIGURE 303.5 FIGURE 303.5 (a) FIGURE 303.5 (b) FIGURE 305.7 (a) FIGURE 305.7 (b) MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS 1/4" = 1'-0" EXIT Nouns SOON moons INTERNATIONALSYMBOL INTERNATIONALTDD INTERNATIONALSYMBOL OF ACCESSIBILITY SYMBOL OF ACCESS FOR HEARING FIGURE 703.6.3.1 FIGURE 703.6.3.2 LOSS FIGURE 703.6.3.3 ADASIGNAGE 1/4" = 1'-0" • • un Ln O n ru r-1 ri r_ n ru N N � r- (3) M 00 00 • .� O 00 00 > •— �O ' Ln (13 Ln E 00 Z3 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z uj W ��-I N O = 0 1 D 0 5m L 00 CL � J O Q zm0 J N m (DW Q Lu W Lu JQQ � z � V) o O Wa zo p �m CE ILL�z waJ U W z~ cn U w M � Q O00 Q O (� rl U Li rl PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 ADAAG / ANSI DETAILS SHEET: GOel NOTE : 0" X 48" OF CLEAR FLOORSPACE IS REQUIRED IN EVERY RESTROOM. WHEN 30" X 48" CLEARFLOOR SPACE IS PROVIDED BEYOND THE ARC OF THE DOOR SWING, THE DOOR IS PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOOR MAY SWING INTO A REQUIRED WHEELCHAIRTURNING SPACE. PER2009 ANSI SECTION 603.2.2, AN EXCEPTION IS MADE IN SINGLE 7'-2" OCCUPANCY TOILET ROOMS TO ALLOW DOOR TO 7'-2" SWING INTO THE REQUIRED FIXTURE CLEAR FLOOR OR 60" MIN. GROUND SPACE \ WHEN ANOTHER CLEAR FLOOROR 60" MIN. 16" 52" 16"-18" GROUND SPACE IS PROVIDED OUTSIDE THE RADIUS OF 16" 52" 16"-1 THE DOOR SWING_01 WALLHUN4&� LAVATORY FLOOR MOUN WALLHUNG TANK -TYPE WATER ��J•� LAVATORY ��� O�� CLOSET��l���Prn O C �0 SHADE AREAS 30" MIN x 48" MIN. C� / SHADE AREAS = CLEAR SPACE 30" MIN x 48" MIN. _ CLEAR SPACE L FLOOR MOUNTED TANK -TYPE WATER (A) CLOSET MINIMUM CLEAR DIMENSIONAL REQUIREMENTS - INWARD DOOR SWING (B) MINIMUM CLEAR DIMENSIONAL SINGLEOCCUPANT TOILET ROOM REQUIREMENTS- OUTWARDDOORSWING 1/4" = 1'-0" 4" MAX. OR 52" MIN. WALLMOUNTED W.C. 4" MA OR 55" MIN. FLOOR MOUNTED 32" MIN. a DOOR o z_ Ln m u u 42" MIN. 12" MAX. 56" WALLMOUNTED W.C. X = 42" 59" MIN. FLOOR MOUNTED W.0 STANDARD STALL FIGURES 604.9.3.1 (a & b) TO I LET STALLS 1/4" = 1'-0" DOOR SHALLNOT SWING INTO THE REQUIRED MIN. AREA OF THE COMPARTMENT 00 56" MIN. WALLMOUNTED W.C. 36" MIN. 59" MIN. FLOOR MOUNTED W.C. STANDARD STALL (END OF ROW) FIGURES 604.9.3.1 (c) 54" MIN. 36" MII N. 39"-41" 12" MI 2" MAX. z_ 24" MIN, 42" MIN. rn c-I c-I m r PROTRUDI - z -1 - m an rn DISPENSER ' cn can `" rnBELOW GRAB - = BAR 4" MIN. 42" MAX. REAR WALL SIDE WALL FIGURE 604.5.2 FIGURE 604.4 FIGURE 604.5.1 FIGURE 604.7 (a) FIGURE 604.11.4 WATER CLOSET GRAB BARS 1/4" = 1'-0" a rn 00 o ,r" RELEASED IFCR CONSTRUCTION Suubjeut to aurnpliance with all regulatimns of State and Vocal Endles ICltp of Cannel ntro DATE: 03/07/18 Nick Mishler Fol X 2 Q Q x X z— 00 a� - �. �. m. " MAX. 8" MIP 17" MIN. Fol X a a z- 00 - a� - �. �. m. " MAX. 6" MIP 17" MIN. oor FIGURE 606.3 2 LAV. CLEARANCES G0.2 1/4" = 1'-0" m i� 42" MIN. A, 2" MAX. 66" MIN. WALL MOUNTED W.C. X = 42" 69" MIN. FLOOR MOUNTED W.C. AMBULATORY STALL FIGURES 604.10 48' MIN 36" BACK 18" J J J O J CONTROLAREA a z � O F N x m 00 bo m rn CONTROLWALL 36" BY 36" STALLGRAB 36" BY 36" STALLSHOWER BARS AT SHOWER STALL SIZE AND CLEARANCES 10 SHOWER REQUIREMENTS 1/4" = 1'-0" 48" MIN. 19" MACl X. 11 z_ 0 m 17" MIN. Tj 48" MIN. 19" MAX. z_ F_ rn 17" MIN.'' LAV. CLEAR FLOOR SPACE 1/4" = 1'-0" 18" N OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA LAV. 60" MIN. CLEARANCE FOR WATER CLOSET FIGURE 604.3 W.C. CLEAR FLOOR SPACE GG 1/4" = 1'-0" 13 1/2" MIN. 13 1/2" MIN. PARTITION PARTITION " MIN. 6" MIN. x a _ � z z WALLHUNG TYPE STALLTYPE FIGURE 605.2 (a) FIGURE 605.2 (b) 7 URINAL CLEARANCES 1/4" = 1'-0" 23" MAX x Q 2 N N Lln cL O 1 1/2" MAX Lu 16"M SHOWER SEAT DESIGN NOTE- Y=36" WHEELCHAIRACCESSIBLE Y= 38" -43" STANDING PERSONS 5" MAX. 15" MIN. 8" MIN. 6" MAX. SPOUT HEIGHT AND KNEE CLEARANCE FIGURE 602.5 (b) DRINKING FOUNTAINS 1/4" = 1'-0" ELEVATION ADULT ELEVATION CHILDREN FIGURE 604.9.5 (a) FIGURE 604.9.5 (b) TOILET STALLS CLEARHEIGHT 1/4" = 1'-0" PLAN FIGURE 604.9.5 (c) • • un Ln O n ru r-1 ri r_ n ru N N � r- (3) M 00 00 • .� O 00 00 > •— �O ' LnLn C (13 00 Z3 0 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z w uj N O NO = 0 1 Z) 5m 00 Z) J O O Q zm0 J N m (DW Q L u W LJJ cl:� J Q � Q z �o () OWa z0 �o 0 CE � �z a w U J Lu z ~ cn U � � V) w Cn R:I- Q O Qo 00 (� rl U L L rl PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 ADAAG / ANSI DETAILS SHEET: G0s2 a 1.0 0 0 N RELEASED IFCR CONSTRUCTION Suubjeut to aornpliance with all regofatimns of State and Ilmeal Endles ICltp of Cannel ntro DATE: 03/07/18 Nick Mishler LIFE SAFETY PLAN 1/4" = 1'-0" 27'-1" LIFE SAFETY GENERAL NOTES A. 36 INCHES REQUIRED AISLE WIDTH MINIMUM. IBC SEC 1017.3. B. ONE EXIT OR ACCESS DOORWAY REQUIRED FOR B,M USES UNDER 50 OCCUPANTS. IBC TABLE 1015.1 C. NO DEAD END CORRIDORS OVER 20'-0" IN LENGTH. (50'-0" ALLOWED FOR B, MUSE WITH FULLY AUTOMATED SPRINKLER SYSTEM). IBC SEC 1018.4 D. MAXIMUM COMMON PATH TRAVELDISTANCE TO AN EXIT IS 75'-0". MEASURED ATTHE MOST REMOTE POINT ALONG THE NATURALAND UNOBSTRUCTED PATH OF HORIZONTALAND VERTICAL TRAVELTO THE EXIT FOR A SPACE WITH MORE THAN 1 EGRESS. FOR B, S OCCUPANCIES, WHERE THE SPACE IS PROVIDED WITH A FULLY AUTOMATED SPRINKLER SYSTEM, THE MAXIMUM DISTANCE IS 100'-0". IBC TABLE 1014.3 E. MAXIMUM EXIT ACCESS TRAVELDISTANCE IS 250'-0" WITH SPRINKLERS. (MUSE), AND 300'-0" WITH SPRINKLERS (B USE). IBC TABLE 1016.2 F. WALKING SURFACES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALLCOMPLY WITH 2O10 ADA SEC 403. G. TRANSITIONS AT DOORWAYS AND BETWEEN FLOORING MATERIALS SHALL NOT BE GREATER THAN 1/2". 2010 ADA SEC 404.2.5 H. DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED MEANS OF EGRESS WIDTH BY MORE THAN 7 INCHES. DOORS IN ANY POSITION SHALLNOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE HALF. IBC SEC 1005.7.1. CODED NOTESO 1. LEASE LINE. 6. EMERGENCY LIGHTING. REFER TO MEP DRAWINGS. 2. PROPOSED FIRE EXTINGUISHER LOCATION. 7. EXISTING STRUCTURALCOLUMN TO REMAIN. 3. EXISTING ELECTRIC PANELAND TRANSFORMER LOCATION. REFER TO ELECTRICALDRAWINGS. 4. ADJACENT TENANT, N.I.C. 5. EXISTING 1—HR RATED DEMISING WALL. FIRE EXTINGUISHER NOTES 1. G.C. TO PROVIDE MIN. OF 1 FIRE EXTINGUISHERS. G.C. TO VERIFY AND COORDINATE LOCATIONS AND QUANTITIES WITH LOCALFIRE MARSHAL. 2. PER IFC, THE MINIMUM IS A 2A1013C EXTINGUISHER WITHIN 75' OF TRAVELDISTANCE OF ALL AREAS. 3. NFPA INSPECTION TAGS SHALL BE ATTACHED TO ALL FIRE EXTINGUISHERS. CALCULATIONS LEASE AREA 743 S.F. LEASE AREA CALCULATIONS F30A (MERCANTILE) 743 S.F. 1 : 30 SF 25 CODE COMPLIANCE MEANS OF EGRESS — INDIANA BLDG CODE (IBC 2006) MEANS OF EGRESS — REQUIRED 1 MEANS OF EGRESS EACH SPACE PROVIDED 1 MEANS OF EGRESS MAX COMMON PATH OF TRAVEL ALLOWED 75'-0" (FULLY SPRINKLERED) PROVIDED 35'-11" FIRE —RESISTANCE RATINGS — EXISTING DEMISING WALLS- (TYPE 1113, SPRINKLERED) 1 HIR RATED LEGEND 36" CLEAR FLOOR SPACE DIRECTION OF TRAVEL • Ln Ln O I- > Ol N N Qjm0000 �tR*rI^ •O Z3 O 00 00 > to •— q* �O >✓ vi l0 l!7 ty0 � Lnaj m Ln E +1 L 00 O U COPYRIGHT 2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z w Ln Lu N O = 0 1 Z) 0 00 CL Z)0 J Q zm0 J N m (DW Q Lu Lu J Q �z Q �o () O Wa z0 �CE a z m w U J Lu z~ cn U � � V) w M Q O Q O (� rl U LL �: r-I PROJECT NUMBER: WPGO07 ISSUE DATE PERMIT FEB. 01, 2018 LIFE SAFETY PLAN SHEET: G0.3 a m77 ai 00 I O N RELEASED IFCR CONSTRUCTION Suubjeut to aornpliance with all regofatimns of State and Ilmeal Endles ICltp of Cannel ntro DATE: 03/07/18 Nick Mishler ARCH ITECTURALFLOOR AND FINISH PLAN 1/4" = 1'-0" REFLECTED CEILING PLAN 1/4" = 1'-0" y WALLPARTITION SCHEDULE SYMBOL DIAGRAM DESCRIPTION DETAIL RATING 5/8" GYPSUM BOARD TO 1/2" ABOVE FRAMING A 1 3 5/8" (20 GA) METALSTUDS @ 24" O.C. CONTINUOUS SOUND BATTS 8/A8.1 --- 5/8" GYPSUM BOARD TO 1/2" ABOVE FRAMING 12'-0" A.F.F. NOTES: 1. FIELD VERIFY ALL DIMENSIONS. DIMENSIONS ARE TO THE FACE SHEATHING UNLESS NOTED OTHERWISE. 2. PROVIDE VERTICALCONTROLJOINTS AT 30'-0" O.C. MAX. SEE DETAILS 4/A1.2 AND 5/A1.2. 3. ALLPARTITIONS THAT ARE TO BE BUILTTO DECK SHALL INCLUDE ANY STRUCTURE (JOISTS, BEAMS, ETC.) THAT MAY NEED TO BE FRAMED OUT IN ORDER TO PROVIDE DRYWALLTO DECK. ALLPENETRATIONS AND FLUTES IN DECKSHALL BE SEALED AS REQUIRED. 4. PROVIDE A GALVANIZED STEELSHEET DEEP LEG DEFLECTION TRACK(20 GA.), 'SLP-TRK' BY SLIPTRACKSYSTEMS, INC. AT ALLFRAMING THAT EXTENDS FROM THE SLAB TO THE UNDERSIDE OF THE STRUCTURE ABOVE. SECURE DEFLECTION TRACKTO STRUCTURE WITH FASTENERS AT 2'-0" O.C. MAXIMUM. DO NOT SECURE TRACKTO VERTICALSTUDS. PROVIDE MINIMUM OF 5/8" TO TOP OF METALSTUD. 5. ALLBOTTOM TRACKRUNNERS ARE TO BE HELD IN PLACE WITH FASTENERS AT 2'-0" O.C. MAX WITH HILTI POWER DRIVER ANCHOR ICBO #2388, .0145" DIAMETER SHANK WITH 1 1/8" MINIMUM PENETRATION. SEE DETAILS 4/A1.2 6. PROVIDE HORIZONTALBRIDGING IN ALLPARTITION FRAMING ATA MINIMUM OF 6'-0" O.C. VERTICALLY. GENERAL CONTRACTOR TO COORDINATE WITH METALSTUD MANUFACTURER TO DETERMINE IF HORIZONTAL BRIDGING IS REQUIRED FOR METALSTUD PARTITION WALLS THAT HAVE GYPSUM BOARD ON BOTH SIDES THAT EXTEND FROM FINISHED FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. 7. METALSTUD NON-STRUCTURALWALLSYSTEMS ARE TO FOLLOW ASTM C754 & ASTM C645. 8. ALLGYPSUM BOARD IS TO BE 5/8" THICK UNLESS NOTED OTHERWISE. PROVIDE TYPE'X' GYPSUM BOARD AT ALLFIRE RATED PARTITIONS. 9. TAPE, MUD, AND SAND GYPSUM BOARD SMOOTH READY FORTENANT FINISHES AT INTERIOR FACE OF ALLGYPSUM BOARD SURFACES. PROVIDE ASTM C840 LEVEL4 FINISH UNLESS NOTED OTHERWISE. 10. ALLPLYWOOD BLOCKING IS TO BE FIRE RETARDANT TREATED. 11. PROVIDE FIRE SAFING AT ALLPARTITION/FURRING CAVITIES AT CEILING LEVELS OPEN TO CEILING PLENUMS. SYMBOLLEGEND O FLOOR PLAN CODED NOTE (SEE SCHEDULE ON THIS SHEET) XX WALLTYPE TAG (SEE SCHEDULE ON THIS SHEET) XXX DOORTAG (SEE SCHEDULE ON SHEET 8.1) WALLLEGEND EXISTING WALL/PARTITION TO REMAIN NEW WALL/PARTITION REFLECTED CEILING PLAN LEGEND ® 24" x 24" SUPPLY AIR DIFFUSER (SEE MECHANICALSHEETS) ❑O 24" X 24" RECESSED TROUGH LIGHT REFER TO ELECTRICALDRAWINGS 24" x 24" RETURN AIR GRILLE (SEE MECHANICALSHEETS) 24" X 48" ACOUSTICALCEILING TILE - ARMSTRONG 1851 DUNE OR APPROVED EQUAL. NOTE - SEE MECHANICALAND ELECTRICALSHEETS FOR ALL FIXTURE SPECIFICATIONS, WIRING, AND POWER REQUIREMENTS. GENERAL FLOOR PLAN NOTES A. ALLUNMARKED WALLS SHALLBE THE SAME AS THE CLOSEST MARKED WALLTYPE. SEE THIS SHEET FOR WALL/PARTITION SCHEDULE. B. GENERAL CONTRACTOR TO PROVIDE ALL NEW WALLS INDICATED ON FLOOR PLAN. SEE WALL/PARTITION SCHEDULE FOR ALLWALLTYPES. C. ALL EXISTING WALLS AFFECTED BY DEMO WORKTO BE PATCHED AND REPAIRED. PROVIDE ASTM C840 LEVEL4 FINISH UNLESS NOTED OTHERWISE. D. REFER TO MEP DRAWINGS FOR ADDITIONALSCOPE OF WORK. ARCH ITECTRUALFLOOR PLN CODED NOTES O 1. EXISTING STRUCTURALCOLUMN TO REMAIN 8. REMOVE EXTERIOR CERAMIC GLAZED TILE UNER STOREFRONTTO EXTERIORSHEATHING. INSTALLNEW 2. EXISTING DEMISING WALL. TAPE, SPACKLE, AND SAND AS MASONRY VENEER PER MANUFACTURER'S REQUIRED TO PROVIDE LEVEL4 FINISH READY TO INSTRUCTIONS. RECEIVE TENANT SELECTED FINISHES 3. EXISTING ELECTRICALPANELS AND TRANSFORMER. REFER TO MEP DRAWINGS. 4. ADJACENT SPACE. N.I.C. 5. LEASE LINE 6. EXISTING EXTERIOR SIDEWALK 7. EXISTING STOREFRONT. FINISH SCHEDULE MARK MANUFACTURER DESCRIPTION NOTES WALL BASE B TBD RUBBER 4" COVE COLOR: TBD BY TENANT WALLS PT-1 SHERMAN WILLIAMS PAINT COLOR: TBD BY TENANT P- TBD FRP PANEL COLOR: TBD BY TENANT CEILING C-1 ARMSTRONG CEILING TILE COLOR: DUNE 1851 GENERALNOTES aim0:11:1:ir l:14:1i1IN1011111:fATMI►MUMgo]:a1[el:Is.]:1Fil191 2. ALLEMERGENCY FIXTURES, LIGHTS AND STROBES SHALLBE ALIGNED OR CENTERED ON WALLS REFLECTED CEILING PLAN CODED NOTES O 1. EXISTING STRUCTURALCOLUMN TO REMAIN. 2. LIGHT FIXTURE. REFER TO ELECTRICALPLANS. 3. MECHANICAL DIFFUSER. REFER TO MECHANICAL PLANS FOR ADDITIONALINFORMATION. 4. EXISTING SOFFIT. SYMBOL LEGEND OFLOOR PLAN CODED NOTE (SEE SCHEDULE ON THIS SHEET) FINISH HEIGHT TAG ALL MODIFICATIONS TO SPRINKLER SYSTEM/ FIREALARM SYSTEM SHALL BE PERFORMED BY LICENSED SPRINKLER/ FIRE ALARM CONTRACTOR UNDER A SEPARATE PERMIT AT DISCRETION OF CONTRACTOR •� LnLnOn r-1 r-I rl � N N rl r- O M 00 00 • .�_ O 00 00 > •- 0 f6cuLn Ln E 4' 00 Z3 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z w 75; Ln W N > 0 nro = 0 1 Z) o 00 CL Z)0 J Q zmo J N m (DW Q W Lu J Q �z Q �o () O Wa z0 �o �m M>-z a w U J Lu z~ cn U � � V) w M Q O Q 0 (� rl U LL �: r-I PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 ARCH ITECTURALFLOOR PLAN AND REFLECTED CEILING PLAN SHEET: Alel ENLARGED RESTROOM PLAN 1/2" = 1'-0" 2 E LEVAT I O N 1/4" = 1'-0" a 00 Ln 0 0 N RELEASED IFCR CONSTRUCTION Suubjeut to aornpliance with all regofatimns of State and Ilmeal Endles ICltp of Cannel ntro DATE: 03/07/18 Nick Mishler YP BOARD FRP 0 m 3 E LEVAT I O N 1/4" = 1'-0" GYPBOARD RUBBER BASE 4 ELEVATION 1/4" = 1'-0" IOARD I:11.1:1evlq 5 E LEVAT I O N A 1.2 1/4" = 1'-0" IOARD TOILET ROOM ACCESSORIES MARK DESCRIPTION/MANUFACTURER NOTES TOILET PAPER DISPENSER - MOUNT AT 24" A.F.F. TO CENTERLINE FURTHER EDGE 1 BOBRICKB-6857 36" FROM REAR WALL GRAB BAR - 42" LONG, 1 1/4"-1 1/2" DIA., MOUNT 12" FROM REAR WALL 2 BOBRICKB-6206x42 33" - 36" A.F.F. GRAB BAR - 36" LONG, 1 1/4"-1 1/2" DIA., MOUNT 6" FROM SIDE WALL 3 BOBRICKB-6206x36 33" - 36" A.F.F. GRAB BAR - 18" LONG, 1 1/4"-1 1/2" DIA., MOUNT CENTERLINE OF BOTTOM RAIL 4 BOBRICKB-6206x18 39" - 41" A.F.F. FRAMED 1/4" MIRROR - 24" WIDTH X 36" HIGH MOUNT WITH BOTTOM OF REFLECTIVE 5 BOBRICKB-294 SURFACE AT 40" A.F.F. 6 WALLMOUNTED SOAP DISPENSER MOUNT TOP OF UNIT AT 4'-1" A.F.F. BOBRICKB-4112 7 SURFACE MOUNTED PAPER TOWEL DISPENSER MOUNT TOP OF UNIT AT 5'-8" A.F.F. BOBRICKB-4262 8 SANITARY NAPKIN DISPOSAL(WOMEN'S ONLY) MOUNT PER MANUFACTURER'S SPECIFICATIONS BOBRICKB-353 REFER TO SHEET G0.3 FOR ADDITIONAL INFORMATION ON ACCESSIBILITY MOUNTING REQUIREMENTS •� LnLnOn r-1 r-I rl n � N N rl r- O M 00 00 4-1n r- • .�_ O 00 00 > •- 0 cubA � Ln Ln E 4' 00 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z w 75; Ln W N > 0 nro = 0 1 Z) 0CL 5m L 00 Z)0 J Q zmo J N M I� (DW Q W Lu �V) JQQ � z �o 0 Wa z0 �m CE LL<z a w U J Lu z~ cn U � � V) w m Q 0 Q 0 00 (� rl U LL � r-I PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 ENLARGED RESTROOM PLAN AND ELEVATIONS SHEET: Als2 5/8" 35/8�5/8" 5/8" GWB OVER METAL FRAMING AS SCHEDULED 20 GA. MTLSTUD TYP @ HEAD CONT. SEALANT BOTH SIDES KNOCKDOWN FRAME, PRIMED DOOR PER SCHEDULE DOOR HEAD DETAIL 1" = 1'-0" RELEASED IFCR CONSTRUCTION Suufv�ankto �aaupdGaNca wrltlo aIV ragaf�timna at State and Ilmeail Endlen IC'Itp at Caimal DATE: 03/07/18 Nick Mishler c /oll o c /oll c /oll 5/8" GWB OVER METAL FRAMING AS SCHEDULED DBL. 20 GA. MTLSTUDSTYP @ JAMBS CONT. SEALANT BOTH SIDES KNOCKDOWN FRAME, W/ (3) JAMB ANCHORS PER SIDE, PRIMED DOOR PER SCHEDULE DOORJAMB DETAIL 1" = 1'-0" 3'-0" FLUSH PANELSOLID CORE WOOD DOOR 1 DOOR ELEVATION_ 1/4" = 1'-0" DOORJAMB SILL 1" = 1'-0" DOOR PER SCHEDULE METAL FRAME BEYOND WEATHERSTRIP ADA COMPLIANT THRESHOLD SET IN SEALANT EXPANSION JOINT DOOR AND FRAME SCHEDULE DOOR FRAME IDETAILS RATING NOTES NO. LOCATION SIZE MATERIAL FINISH ELEV. HARDWARE SET PROFILE MATERIAL FINISH JELEV. IHEAD JJAMB7SILL 100 ENTRY EXISTING --- --- --- 1 EXISTING 101 RESTROOM T-0" x 7'-0" x 1 3/4" SOLID CORE WOOD PAINT 1/A8.1 2 3/A8.1 K.D.H.M. I PAINT I 2/A8.1 I 4/A8.1 I 5/A8.1 I 6/A8.1 NOTES: 1. ALL DOOR LOCKSETS / PASSAGE SETS SHALL BE OF THE LEVER HANDLE TYPE. HARDWARE SHALL BE MOUNTED NO HIGHER THAN 48" ABOVE FINISHED FLOOR (MOUNTED BETWEEN 44" TO 48"). PROVIDE LEVER HANDLE AT ALL HANDICAPPED ACCESSIBLE DOORS. MAXIMUM PULL FORCES FOR INTERIOR DOORS TO BE 5.0 LBS FORCE. MAXIMUM PULL FORCES FOR EXTERIOR DOORS TO BE 15.0 LBS FORCE. 2. PER ADAAG 4.16.6 - MINIMUM MANEUVERING CLEARANCE AT DOORS THAT ARE NOT AUTOMATIC OR POWER -ASSISTED / FOR FRONT APPROACHES TO PUSH SIDE OF DOORS, NOT EQUIPPED WITH LATCH AND CLOSER SHALLHAVE MANEUVERING SPACE THAT IS THE SAME WIDTH AS DOOR OPENING AND EXTENDS 48-INCHES MINIMUM PERPENDICULARTO THE DOORWAY. DOORS WILLBE PROVIDED WITH 36" X 48" MANEUVERING CLEARANCE ON PUSH SIDE WHEN NOT EQUIPPED WITH LATCH AND CLOSER. AT PULLSIDE OF DOOR, 18-INCH EXTENSION BEYOND LATCH SIDE OF DOOR IS PROVIDED. 3. VERIFY ALLROUGH OPENING SIZES AND REQUIREMENTS WITH DOOR MANUFACTURER. 4. INTERIOR SOLID CORE WOOD DOORS TO BE BIRCH VENEER PAINT GRADE. PAINT WOOD DOORS SEMI -GLOSS AS SCHEDULED. 5. PROVIDE SOLID F.R.T. WOOD BLOCKING WITHIN STUD WALL FRAMING ADJACENT TO STRIKE PLATE. BLOCKING TO EXTEND MIN. 12" ABOVE AND BELOW STRIKE PLATE. 6. ALL LOCKSETS TO BE PROVIDED WITH REMOVABLE CONSTRUCTION CORE CYLINDERS SUPPLIED BY HARDWARE MANUFACTURER. CONTRACTOR TO PROVIDE OWNER WITH PERMANENT CORE CYLINDERS FOR MASTER KEYING BY CONTRACTOR AT THE COMPLETION OF THE PROJECT. 7. ALL HARDWARE TO COMPLY W/THE LATEST REQUIREMENTS OF ADAAG/ANSI. 8. KEYING SEQUENCE TO BE COORDINATED W/ OWNER'S PROPERTY MANAGER. 9. PAINT FRAME AND DOOR TO MATCH MALLSTANDARDS. 2" 3'-0" 2" N 0 n INTERIOR (16 GA.) WELDED HOLLOW METAL FRAME ELEVATION 1/4" = 1'-0" NEW BREAKMETALTRIM CAP TO MATCH STOREFRONT. 5/8" GWB DOOR HARDWARE SCHEDULE HARDWARE SET #1 - ENTRY QTY. DESCRIPTION MANUFACTURER NUMBER FINISH 3 EA. HINGES IVES 5BB1 4.5 x 4.5 652 1 EA. SURFACE BOLT IVES SB453 8" TB 652 1 EA. ENTRANCE/OFFICE LOCK SCHLAGE ND50HD RHO 626 1 EA. WALLSTOP IVES WS33 626 HARDWARE SET #2 - RESTROOM QTY. DESCRIPTION MANUFACTURER NUMBER FINISH 3 EA. HINGES IVES 5BB1 4.5 x 4.5 652 1 EA. PRIVACY LOCK SCHLAGE S219OD-JUP 200 SERIES NICKEL 2 EA. WALLSTOP IVES WS33 626 2 EA. SILENCER IVES SR64 GRY 1 EA. CLOSER LCN 4010 ALUM ALLLOCKABLE DOORS SHALLBE EQUIPPED WITH REMOVABLE CORE HARDWARE, MANUFACTURED BY "SCHLAGE". HARDWARE TO BE SUPPLIED FROM THE MANUFACTURER WITH "SCHLAGE" REMOVABLE CORE CYLINDERS WITH CONSTRUCTION MASTER -KEYING. 2„ 5/8" 00 Ln 00 a Z 0 z N Lu V1 Of LuoC =a a 11 w �0 > LU LL 0 of 00 Ln \ Ln HOLLOW METAL 3 FRAME PROFILE A$.1 3" = 1'-0" EXTERIORWALL DETAIL 1" = 1'-0" EXISTING STOREFRONT EXISTING VENEER CONSTRUCTION NEW MASONRY VENEER. FINISH TBD BY OWNER. WALLBRACING AS REQUIRED T.O. METAL STUD PARTITION, REFER TO WALL BRACING LEGEND ABOVE REFER TO PLANS T.O. STUD REFER TO PLANS B.O. SUSPENDED CEILING FULLWIDTH SOUND BATT INSULATION IICrda 1.1 197e\:111 1► i�re���rn.�� i�i►i�y:�rrz•�:�e��Yya�.l��r�. 100'-0" Y FINISHED FLOOR WALLSECTION 1/2" = 1'-0" •� •LnLnOn ro r-1 ri r- n ro N N r-� r- O M 00 00 . .�_ O 00 00 > •- 0 cubA � Ln Ln E 4' 00 Z3 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. v z w 75; Ln W N > O = O 1 Z) � Im 0 0 CL Z) J 0 Q Q zmo J N M I� (DW Q Lu Lu J Q Crz Q �o () 0 Wa z0 �m CE LL<z a w U J Lu z~ cn U � � � w m Rl- Q O Q o (� rl U LL �: r-I PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 DOOR SCHEDULE AND DETAILS SHEET: A8ol SHEET NOTES: GENERAL A. WHERE ITEMS/ELEMENTS ARE INDICATED HEREIN TO BE LISTED/APPROVED, THE INTENT OF THIS L. FIRE PROTECTION ITEMS AND ELEMENTS SHALL BE INSTALLED WITH DUE REGARD TO 2. ALL RODS, ANGLES, RAILS, STRUTS, BRACES, PLATES, PLATFORMS, ETC., REQUIRED 5. SPRINKLERS; AS SPECIFIED ON PLANS. SPECIFICATION IS THAT SAID ITEM/ELEMENT SHALL BE LISTED BY ALL APPLICABLE PRESERVATION OF THE STRENGTH OF STRUCTURAL MEMBERS AND PREVENTION OF DAMAGE TO FOR SUSPENSION AND/OR SUPPORT OF PIPING, AND ALL MISCELLANEOUS MATERIAL/CONSTRUCTION STANDARDS, AND SUBJECT TO FINAL APPROVAL (INCLUDING WALLS, SURFACES AND OTHER STRUCTURES THROUGH INSTALLATION, BEARING SUPPORT OR SPECIALTIES AND ITEMS/ELEMENTS REQUIRED FOR THE ATTACHMENT OF HANGERS A. SPARE SPRINKLER HEAD CABINET - PROVIDE CABINET AT MAIN RISER LOCATION WITH METHODS OF INSTALLATION) BY ALL REVIEW/INSPECTION/APPROVAL AUTHORITIES. SUBSEQUENT USAGE OF FIRE PROTECTION ITEMS AND ELEMENTS. NO FRAMING OR OTHER AND SUPPORTS TO THE STRUCTURE. SPRINKLER HEADS AND HEAD WRENCH(ES) FOR EMERGENCY USE. SPARE HEAD QUANTITIES TO BE AS SPECIFIED BY NFPA PAMPHLET NO. 13, CORRESPONDING B. UNLESS INDICATED OTHERWISE, ALL FIRE PROTECTION CONTRACT ITEMS/ELEMENTS (PIPE, FITTINGS, SUPPORT STRUCTURE SHALL BE CUT NOTCHED OR BORED IN EXCESS OF LIMITATIONS SPECIFIED D. UNLESS OTHERWISE NOTED, HANGERS SHALL BE AS FOLLOWS: PROPORTIONALLY TO THE TOTAL NUMBER OF EACH TYPE INSTALLED IN THE BUILDING. VALVES, SPECIALTIES, FIXTURES, EQUIPMENT, ETC.) MATERIALS, CONSTRUCTION, PERFORMANCE, IN THE BUILDING CODE, OR BY THE MANUFACTURER OF THE FRAMING OR OTHER SUPPORT B. ALL SPRINKLER HEADS IN LIGHT AND ORDINARY HAZARD OCCUPANCY APPLICATIONS TO TESTING AND METHODS OF INSTALLATION TO BE AS LISTED/APPROVED BY ALL APPLICABLE STRUCTURE, AS CONFIRMED IN ADVANCE OF WORK BY THE FIRE PROTECTION CONTRACTOR. l . PIPING 8" SIZE AND SMALLER, HANGER SHALL BE SIMILAR TO GRINNELL FIG. 69, WITH BE LISTED/APPROVED "QUICK RESPONSE'' TYPE. GALVANIZED ADJUSTABLE NUT AND CARBON STEEL BAND. MATERIAL/CONSTRUCTION/INSTALLATION STANDARDS FOR SAME, AND BE IN ACCORDANCE FIRE PROTECTION PIPING SYSTEM - WET C. SPRINKLER HEADS AS MANUFACTURED/PROVIDED BY RELIABLE, AUTOMATIC, CENTRAL, WITH THE REQUIREMENTS OF ALL REVIEW/INSPECTION/APPROVAL AUTHORITIES. THIS INCLUDES, 2. PIPING 10'' SIZE AND LARGER, HANGER SHALL BE SIMILAR TO GRINNELL FIG. 260, GRINNELL, VIKING OR VICTAULIC MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. BUT IS NOT LIMITED TO, THE STANDARDS AND AUTHORITIES REFERENCED IN THIS SPECIFICATION. IN PRODUCTS CARBON STEEL, ADJUSTABLE WROUGHT CLEVIS TYPE. THE ABSENCE OF SUCH STANDARDS AND/OR REQUIREMENTS, THE ITEM/ELEMENT 1. PIPING AND FITTINGS 3. TRAPEZE HANGERS EXECUTION MANUFACTURER'S RECOMMENDATIONS, AS CONFIRMED BY THE FIRE PROTECTION CONTRACTOR IN ADVANCE, SHALL BE FOLLOWED. A. PIPE SHALL BE SCHEDULE 40 BLACK STEEL WITH CLASS 125 CAST OR MALLEABLE IRON A. WHERE SEVERAL PIPES OCCUR AT THE SAME ELEVATION, TRAPEZE TYPE 1. INSTALLATION SCREWED FITTINGS PER NFPA STANDARDS. THE CONTRACTOR HAS THE OPTION TO HANGERS MAY BE USED. TRAPEZE HANGERS SHALL BE SIMILAR TO GRINNELL C. ALL FIRE PROTECTION CONTRACT ITEMS/ELEMENTS SHALL HAVE THE MANUFACTURER'S MARK OR PROVIDE SCHEDULE 10 BLACK STEEL PIPE FOR 2" TO 6" (INCLUSIVE) PIPE SIZE WITH FIG. 46 WITH GRINNELL FIG. 137 U-BOLT OR FIG. 262 STRAP. BRACKET SHALL A. PROVIDE DRAIN VALVES AND AUXILIARY DRAINS PER NFPA REQUIREMENTS, AND AT LOW NAME AND THE QUALITY OF THE PRODUCT OR IDENTIFICATION OF SAME CAST, EMBOSSED, LISTED/APPROVED ROLL GROOVED MECHANICAL COUPLING FITTINGS AS SPECIFIED HEREIN. BE GRINNELL FIG. 195. POINTS OF SYSTEM TO ALLOW COMPLETE DRAINAGE. CONTRACTOR TO BE RESPONSIBLE THREADED FITTINGS OR CUT GROOVE COUPLINGS NOT PERMITTED WITH SCHEDULE 10 TO INSTALL SPRINKLER SYSTEM TO DRAIN PROPERLY. PIPING SHALL BE INSTALLED TO STAMPED OR INDELIBLY MARKED ON EACH ITEM/ELEMENT IN ACCORDANCE WITH THE PIPE. DRAIN AT THE MAIN RISER WHENEVER POSSIBLE. STANDARDS UNDER WHICH THEY ARE ACCEPTED AND APPROVED PER APPLICABLE CODE(S). 3. VALVES AND SPECIALTIES B. ALL SCHEDULE 10 PIPE SHALL USE LISTED/APPROVED GROOVED FITTINGS WITH A. WEDGE DISC BRONZE GATE VALVES -LISTED/APPROVED OUTSIDE SCREW AND YOKE, , , B. INSTALL VALVES AND SPECIALTIES WHERE INDICATED AND/OR AS REQUIRED FOR APPROVAL. D. CONNECTIONS TO EXISTING BUILDING UTILITIES SHALL BE MADE WITH APPROVED MATERIALS OF MALLEABLE IRON MECHANICAL COUPLINGS SIMILAR TO THAT MANUFACTURED BY SCREWED TYPE FOR SIZE 2" AND SMALLER, FLANGED FOR SIZES 2-1/2'' AND LARGER, THE SAME TYPE AS, OR LISTED FOR COMPATIBILITY WITH, EXISTING MATERIALS. MATERIAL TYPES VICTAULIC. THE CONTRACTOR MAY, AT HIS OPTION FOR SCHEDULE 40 PIPE 2" SIZE AND WITH IRON BODY AND BRONZE FITTINGS. COUNTERCLOCKWISE OPENING AND 175 PSIG C. THE ENTIRE SPRINKLER SYSTEM INSTALLATION SHALL CONFORM TO THE REQUIREMENTS TO BE VERIFIED BY THIS CONTRACTOR IN THE FIELD IN ADVANCE OF WORK. LARGER, USE LISTED/APPROVED GROOVED FITTINGS AND MALLEABLE IRON MECHANICAL WORKING PRESSURE. USE NON -RISING -STEM TYPE FOR POST INDICATING VALVE OF NFPA PAMPHLET NO. 13. COUPLINGS SIMILAR TO THAT MANUFACTURED BY VICTAULIC. ASSEMBLIES. D. PIPING MUST BE LINED UP PARALLELING AND AT RIGHT ANGLES TO THE BUILDING WALLS E. UNLESS INDICATED OTHERWISE, ALL FIRE PROTECTION PIPING SHALL BE IN ACCORDANCE WITH l . COUPLINGS SHALL BE SIMILAR TO VICTAULIC RIGID STYLE 005 FIRELOCK WITH EDPM 1. WHERE GATE VALVES ARE INDICATED ON PLANS, THE CONTRACTOR MAY, AT HIS AND OTHER PRIMARY STRUCTURAL ELEMENTS; ANGULAR OFFSETS SUCH AS 45' CUTS THE FOLLOWING STANDARDS IN REGARD TO MATERIALS, CONSTRUCTION, GASKET AND HOUSING FABRICATED IN TWO OR MORE PARTS OF MALLEABLE IRON OPTION, USE BUTTERFLY VALVES AS SPECIFIED IN SECTION 15027, PROVIDED THEY ACROSS CORNERS AND ELSEWHERE WILL NOT BE PERMITTED UNLESS SPECIFICALLY DIMENSIONS/TOLERANCES AND METHODS OF INSTALLATION (AS APPLICABLE), AND SHALL BE CASTINGS. LISTED OUTLET COUPLINGS MAY BE USED SUBJECT TO APPROVAL BY ALL ARE LISTED/APPROVED FOR FIRE PROTECTION SERVICE. SHOWN. SO LISTED. FINAL APPROVAL FOR USE IS SUBJECT OF THE REQUIREMENTS OF THE REVIEW AND REVIEW AND INSPECTION AUTHORITIES. FINAL ASSEMBLIES SHALL BE RATED FOR 175 PSIG WORKING PRESSURE. E. THIS CONTRACTOR MUST ASSUME THE FULL RESPONSIBILITY OF VERIFYING PRESENT INSPECTION AUTHORITIES. B. WATER PRESSURE GAUGES - LISTED/APPROVED 3-1/2" BRASS PRESSURE GAUGES RANGE ELEVATIONS IN THE FIELD AND MAKING ANY ADJUSTMENTS AS MAY BE NECESSARY, ALL 2. ASSEMBLY AND INSTALLATION OF COUPLINGS TO BE IN ACCORDANCE WITH THE 0 TO 300 PSIG, WITH NPT MALE PIPE CONNECTION. INSTALL AT EACH INSPECTOR'S TEST OF WHICH MUST BE INCLUDED IN HIS PROPOSAL PRICE. F. STEEL PIPE, MALLEABLE AND CAST IRON FITTINGS AND JOINING METHODS; SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. CONNECTION, ALARM VALVE AND ELSEWHERE AS REQUIRED, AND/OR AS SHOWN ON PLANS. F. PROVIDE SLEEVES FOR PIPES WHERE PIPING PENETRATES MASONRY WALLS. ALL PIPE APPLICABLE ASTM/ANSI/ASME STANDARDS. 3. PIPE GROOVING SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S PENETRATIONS THROUGH MASONRY WALLS SHALL BE ADEQUATELY SEALED WITH MORTAR SPECIFICATIONS. ROLL GROOVING ONLY PERMITTED FOR SCHEDULE 10 PIPE: ROLL OR C. CONTRACTOR TO FURNISH AND INSTALL IDENTIFICATION SIGNAGE WHERE REQUIRED, OR APPROVED FIRE RESISTANT CAULKING. G. WHERE STANDARDS, CODES OR GUIDELINES ARE REFERENCED HEREIN AND THROUGHOUT THE CUT GROOVING MAY BE USED FOR SCHEDULE 40 PIPE, AT THE CONTRACTOR'S SIMILAR TO RELIABLE MODEL A. AS A MINIMUM, AN ENGRAVED SIGN SHALL BE PROVIDED FIRE PROTECTION CONTRACT DOCUMENTATION, INCLUDING PLANS AND SPECIFICATIONS, THE OPTION. AT THE MAIN SUPPLY RISER/CONTROL VALVE INDICATING BASIC DESIGN INFORMATION. 2. SPRINKLER HEADS LATEST VERSION/EDITION SHALL BE APPLIED, UNLESS THE BUILDING CODE REFERENCES ANOTHER 4. THE CONTRACTOR MAY, AT HIS OPTION, PROVIDE EQUAL MECHANICAL COUPLINGS AS D. SPRINKLER VALVES AND ACCESSORIES AS MANUFACTURED/PROVIDED BY RELIABLE, VERSION/EDITION, WHICH SHALL TAKE PRECEDENCE. MANUFACTURED BY ITT GRINNELL, ANVIL GRUVLOK OR CENTRAL SPRINK, MEETING ALL AUTOMATIC, CENTRAL, GRINNELL, VIKING OR VICTAULIC MAY BE FURNISHED AT THE A. QUANTITY AND LOCATION OF SPRINKLER HEADS TO BE DETERMINED BY THE FIRE H. REFER TO PROJECT DOCUMENTATION FURNISHED WITH THE COMPLETE CONSTRUCTION REQUIREMENTS LISTED FOR GROOVED PIPING INSTALLATION. CONTRACTOR'S OPTION. ACCORDANCE WITH SPECIFICATIONS ON PLANS. PACKAGE IN ADVANCE OF WORK FOR OVERALL COORDINATION AND VERIFICATION OF 5. ELEMENTS DESCRIBED ELSEWHERE IN THIS SPECIFICATION MAY BE PROVIDED WITH REQUIREMENTS AT WORK OF OTHER TRADES RELATING TO, INTERFACING WITH, AND/OR COMPATIBLE ALTERNATE CONNECTIONS WHEN INSTALLED IN MECHANICAL COUPLING 4. ALARM INITIATING DEVICES B. UNLESS INDICATED OR REQUIRED OTHERWISE, NOMINAL SPRINKLER HEAD OPERATING PIPING SYSTEMS. THE MECHANICAL COUPLING CONNECTIONS FOR THESE ELEMENTS TEMPERATURE RATINGS TO BE AS FOLLOWS: IMPACTING WORK IN THE FIRE PROTECTION CONTRACT. THIS INCLUDES EXACT LOCATIONS, MUST BE PROVIDED BY THE MANUFACTURER WITH APPROPRIATE LISTINGS, A. GATE VALVE SUPERVISORY SWITCHES - FURNISH AND INSTALL LISTED/APPROVED 1. FINISHED, GENERAL ACCESS AREAS - 175 DEGREES F. QUANTITIES, PHYSICAL SIZES, ROUGH -IN DETAILS, PIPE ROUTING, CONNECTION SIZES, ETC., FOR APPROVALS AND PRESSURE RATINGS AS SPECIFIED. THIS INCLUDES VALVES, SUPERVISORY SWITCHES ON ALL TYPES OF SHUT-OFF VALVES CAPABLE OF INTERRUPTING 2. NON -FINISHED, RESTRICTED ACCESS AREAS (MECHANICAL/ELECTRICAL UTILITY ITEMS INCLUDED BOTH IN THE FIRE PROTECTION CONTRACT AND UNDER SEPARATE CONTRACT. APPURTENANCES, EQUIPMENT AND OTHER ELEMENTS INSTALLED IN OR CONNECTED TO FLOW IN THE SPRINKLER SYSTEM. COORDINATE INSTALLATION AND INTERFACE REQUIREMENTS WITH THE APPROPRIATE MECHANICAL COUPLING PIPING SYSTEMS. ROOMS, STORAGE ROOMS, ETC.) - 200 DEGREES F. CONTRACTOR(S) IN ADVANCE OF WORK. 2. PIPING HANGERS AND SUPPORTS B. FLOW SWITCH - LISTED/APPROVED VANE -TYPE WATERFLOW DETECTOR WITH PIPE SADDLE 3. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO DETERMINE IF CONNECTION FITTING, U-BOLT SECURING ASSEMBLY, ADJUSTABLE PNEUMATIC RETARD TO SPRINKLERS WITH TEMPERATURE RATINGS OTHER THAN THOSE INDICATED HEREIN ARE I. INCLUDE ANY MINOR DETAILS, ITEMS AND/OR ELEMENTS ESSENTIAL TO NECESSARY APPROVALS A. PIPING SHALL BE ADEQUATELY SUPPORTED BY MEANS OF HANGERS AND SUPPORTS, AND PREVENT FALSE ALARMS AND TWO (2) SETS OF FORM "C" CONTACTS. MAXIMUM PRESSURE RATING OF 300 PSIG. REQUIRED DUE TO SPECIFIC CONDITIONS AT EACH INSTALLATION, AND PROVIDE AND SUCCESSFUL OPERATION IN ADDITION TO THE ITEMS SPECIFIED HEREIN AND SHOWN ON BE IN COMPLIANCE WITH NFPA PAMPHLET 13. CARRY OVERHEAD LINES DIRECTLY ON SPRINKLERS WITH APPROPRIATE TEMPERATURE RATING AT THESE LOCATIONS. PLANS. SUPPORTS OR SUSPEND BY HANGERS FROM SUPPORTS. FURNISH REQUIRED SUPPORTING STEEL, HANGERS, ETC. C. PRESSURE SWITCH - FURNISH PRESSURE DIFFERENTIAL TYPE SWITCH ASSEMBLIES FOR C. RECESS SPRINKLER HEADS TO BE INSTALLED WITH DEFLECTORS NO GREATER THAN 1 /2" J. WHERE EXISTING ITEMS/ELEMENTS ARE INDICATED TO BE REUSED AS A PART OF NEW WORK, THE ALARM ACTUATION, ADJUSTABLE TYPE FOR SUPERVISORY FUNCTIONS. SWITCHES TO BE FROM MAXIMUM RECESSED CAPABILITY. DEFLECTORS OF ADJACENT HEADS TO BE AT B. PIPING AT EQUIPMENT AND CONTROL VALVES, ETC. SHALL BE SUPPORTED SO THAT AUTOMATIC RESETTING, SINGLE POLE/DOUBLE THROW. MAXIMUM PRESSURE RATING OF SAME ELEVATION, PLUS OR MINUS 1 /4". FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR ACTION REQUIRED TO ASSURE THAT SUCH THOSE ELEMENTS/ITEMS CAN BE REMOVED WITHOUT PROVIDING ADDITIONAL SUPPORT 300 PSIG. ITEMS/ELEMENTS WILL FUNCTION PROPERLY IN THE COMPLETED REVISED SETTING, AND BE IN ELEMENTS. PIPING SHALL NOT INTRODUCE ANY STRAINS OR DISTORTIONS ON CONNECTED D. SPRINKLER HEADS TO BE ALIGNED IN RESPECT TO STRUCTURE, AND ADJACENT HEADS TO COMPLIANCE WITH THE REQUIREMENTS OF THE REVIEW, INSPECTION AND APPROVAL EQUIPMENT. VERTICAL PIPING SHALL BE SUPPORTED AT BASE OF RISER. D. ALARM INITIATING DEVICES AS MANUFACTURED/PROVIDED BY FCI, NOTIFIER, HONEYWELL, PRESENT A UNIFORM, EVEN LINEAR APPEARANCE. AUTHORITIES. THIS INCLUDES REMOVAL, CLEANING AND/OR RECONDITIONING OF POTTER, SYSTEM SENSOR OR ANY OF THE MANUFACTURERS LISTED FOR SPRINKLER ITEMS/ELEMENTS IF REQUIRED. C. THE FOLLOWING ITEMS SHALL BE PROVIDED: EQUIPMENT AND ACCESSORIES MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. E. SPRINKLER HEAD TYPE AND FINISH TO BE DETERMINED BY THE ARCHITECT AND 1. SUPPLEMENTARY CHANNELS, PLATES, ETC. WHERE SUPPORTS ARE REQUIRED BETWEEN CONSTRUCTION MANAGER. SEE FIRE PROTECTION GENERAL NOTES ON THIS SHEET. K. SEE GENERAL "FIRE PROTECTION NOTES'' ON PLANS FOR ADDITIONAL CONDITIONS AND BUILDING STRUCTURAL MEMBERS, SPANNING THE SPACE AND ATTACHED TO BUILDING REQUIREMENTS RELATIVE TO THE FIRE PROTECTION CONTRACT. STRUCTURAL MEMBERS BY WELDING OR BOLTING. Ln 0 00 r o RELEASED IFCR CONSTRUCTION 5uud9ezttncnmiplanumwith 311llse9ubtmma _ of State and lmeal Endes 0tp at Caimal ntro DATE: 03/07/18 Nick Mishler FLOOR PLAN - FIRE PROTECTION 1 /4" = 1'-0" EN SPRINKLER HEAD LOCATION NOTES: l . ALL LOCATIONS INDICATED ARE TO BE MAINTAINED WITHIN PLUS OR MINUS 1 /2", AND ALIGNED WITH ADJACENT HEADS FOR A UNIFORM, EVEN APPEARANCE OF COMPLETED INSTALLATION. POSITIONS INDICATED APPLY TO FULL SIZE SMOOTH SURFACE TILES, AS WELL AS FULL SIZE SUB-GRIDDED (SCORED OR GRAPHICALLY DIVIDED) SURFACE TILES. THE APPEARANCE OF THE FINISHED CEILING TILE FACE AS INSTALLED OVERRIDES THE ACTUAL PHYSICAL DIMENSIONS OF THE TILE FOR PLACEMENTS INDICATED HEREIN. VERIFY CEILING TILE TYPES FROM ARCHITECTURAL DOCUMENTATION. 2. RECESSED PENDANT SPRINKLER HEADS TO BE INSTALLED WITH DEFLECTORS AT SAME ELEVATION AS ADJACENT SPRINKLERS IN SAME AREA/ENCLOSURE, PLUS OR MINUS 1 /4''. RECESSED HEADS TO BE INSTALLED SO DEFLECTOR IS A MAXIMUM OF 1" BELOW THE ELEVATION OF THE CEILING PLANE. CONCEALED HEADS TO BE INSTALLED WITH COVERS FLUSH TO CEILING PLANE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 3. INSTALLATION OF ALL SPRINKLER HEADS TO BE COORDINATED WITH STRUCTURE AND WORK OF OTHER TRADES, VERIFIED IN ADVANCE BY THE FIRE PROTECTION CONTRACTOR. 4. VERIFY EXACT TYPE, FINISH AND LOCATION OF ALL HEADS WITH ARCHITECT AND AND CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. 24"x24" CEILING TILE 12"x48" CEILING TILE 24"x48" CEILING TILE N N 12" 12"lo ol 10 18" 6" 12"xl2" CEILING TILE 12"x48" CEILING TILE 24"x48" CEILING TILE DETAIL - SPRINKLER HEAD LOCATION N.T.S. FIRE PROTECTION MATERIAL &EQUIPMENT SCHEDULE l . FINAL DECISION ON THE FINISH AND OR COLOR AND STYLE OF SPRINKLER HEADS TO BE DETERMINED BY THE ARCHITECT DURING THE REVIEW PROCESS. 2. THE ARCHITECT RESERVES THE RIGHT TO RELOCATE OR ADD SPRINKLER HEADS TO THE SPRINKLER CONTRACTOR'S LAYOUT. FIRE PROTECTION SPRINKLER HEADS A. RECESSED PENDENT HEADS; SIMILAR TO VIKING MODEL VK302 WITH 1 /2" STD. ORIFICE, 1 /2" NPT INLET, OUTLET SPRAY DEFLECTOR, 5.6 "K" FACTOR & ADJUSTABLE TWO-PIECE ESCUTCHEON. ESCUTCHEON & HEAD TO BE FURNISHED WITH MANUFACTURER APPLIED WHITE FINISH. HEAD TO BE LISTED "QUICK RESPONSE'' TYPE. SIDEWALL HEADS (IF REQUIRED) TO BE SIMILAR, WITH HORIZONTAL DEFLECTOR. INLET, ADJUSTABLE DRY BARREL AND COMPRESSED CENTER STRUT ACTUATOR. PENDENT AND SIDEWALL HEADS FOR USE IN AREAS WITH CONCEALING "FINISH" STRUCTURE WITH CONCEALED SUPPLY PIPING. B. CONCEALED PENDENT HEADS: TO BE USED IN ALL CEILINGS UNLESS NOTED OTHERWISE. SIMILAR TO VIKING MODEL VK462 WITH 1 /2'' STD. ORIFICE, 1 /2'' NPT INLET, OUTLET SPRAY DEFLECTOR, 5.6 "K" FACTOR, ADJUSTABLE TWO-PIECE ESCUTCHEON AND COVERPLATE WITH MANUFACTURER APPLIED WHITE FINISH. HEAD TO BE LISTED''QUICK RESPONSE" TYPE. UNLESS NOTED OTHERWISE, IN AREAS WITH DRYWALL, PANELBOARD OR OTHER DROP CEILING STRUCTURE WITH CONCEALED SUPPLY PIPING. HEADS LOCATED IN WOOD PANELS TO BE PROVIDED WITH MANUFACTURER APPLIED FINISH COLOR FOR COVERPLATE AS APPROVED BY THE OWNER'S REPRESENTATIVE IN ADVANCE OF INSTALLATION. EQUAL MANUFACTURER'S: RELIABLE, VIKING, AUTOMATIC, CENTRAL, GUARDIAN, VICTAULIC, POTTER-ROEMER OR GRINNELL MAY BE PROVIDED AT THE CONTRACTOR'S OPTION NOTE; A. FOR BIDDING PURPOSE THIS CONTRACTOR SHALL PROVIDE CONCEALED HEADS IN ALL DRYWALL CEILINGS AND/OR SPECIAL CONSTRUCTION CEILINGS. FOR ALL ACOUSTICAL TILE CEILINGS THIS CONTRACTOR SHALL PROVIDE RECESSED SPRINKLER HEADS. ALL FINISHES AND OR COLORS OF SPRINKLER HEADS SHALL BE DETERMINED BY THE ARCHITECT USING THE STANDARD AVAILABLE COLORS OR FINISHES AVAILABLE FROM THE MANUFACTURER. FIRE PROTECTION SPRINKLER PIPING A. WET SPRINKLER PIPING, ASTM LISTED SCHEDULE 40 BLACK STEEL PIPE WITH THREADED IRON FITTINGS, OR SCHEDULE 40 BLACK STEEL ROLL GROOVED PIPE WITH GASKETED IRON MECHANICAL COUPLINGS SIMILAR TO VICTAULIC SERIES 005 FIRELOCK RIGID TYPE. PIPING SIZES 2-1/2" AND LARGER MAY BE ASTM LISTED SCHEDULE 10 BLACK STEEL ROLL GROOVED PIPE WITH MECHANICAL COUPLINGS AS PREVIOUSLY SPECIFIED. ALL GROOVED PIPING TO BE ROLL TYPE; CUT GROOVES NOT PERMITTED. PIPING INSTALLATION TO BE RATED FOR 175 PSIG WORKING PRESSURE. B. ALL FIRE PROTECTION PIPING TO BE IN ACCORDANCE NFPA PAMPHLET NO. 13, NFPA 9.1 AND NFPA 9.1.3 REQUIREMENTS FOR MATERIALS AND METHODS OF INSTALLATION. C. HANGERS TO BE SIMILAR TO GRINNELL FIG. 69 WITH GALVANIZED ADJUSTABLE NUT AND CARBON STEEL BAND. INSTALL IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, NFPA 9.1 AND NFPA 9.1.3 REQUIREMENTS FOR MATERIALS AND METHODS OF INSTALLATION. D. TESTING OF PIPING TO MEET NFPA REQUIREMENTS. FIRE PROTECTION NOTES: A. PROVIDE ALTERATIONS AND MODIFICATIONS AS NECESSARY TO FURNISH AND INSTALL A COMPLETE FULLY AUTOMATIC WET PIPE FIRE PROTECTION SYSTEM INCLUDING PIPING, HANGERS, VALVES, ALARMS, SUPPORTS AND SPRINKLER HEADS PER NFPA PAMPHLET NO. 13. THE SYSTEM SHALL COMPLY WITH ALL REQUIREMENTS OF LOCAL, STATE AND FEDERAL AUTHORITIES AND LANDLORD'S INSURING AGENCY. B. ALL WORK SHALL BE PERFORMED BY AN APPROVED AUTOMATIC FIRE PROTECTION SPRINKLER CONTRACTOR. SHOP DRAWINGS AND CALCULATIONS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL ENGINEER. APPROVED CONTRACTOR AND THE CONTRACTOR'S REGISTERED ENGINEER SHALL BE LICENSED WITH THE PROPER AUTHORITIES FOR THE STATE OF TENNESSEE. C. DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL INTENT OF WORK. FINAL CONSTRUCTION DOCUMENTS, HYDRAULIC CALCULATIONS AND PERMITTING SHALL BE BY THE FIRE PROTECTION CONTRACTOR. D. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR THE EXACT NUMBER, DENSITY, TYPE AND LOCATION OF SPRINKLER HEADS AS WELL AS PIPING LAYOUTS INCLUDED IN THE SET OF CERTIFIED STAMPED SHOP DRAWINGS PROVIDED BY THE FIRE PROTECTION CONTRACTOR. E. ALL AUTHORITIES HAVING JURISDICTION SHALL BE NOTIFIED AT LEAST THREE (3) WORKING DAYS PRIOR TO COMMENCEMENT OF WORK. F. FIRE PROTECTION CONTRACTOR SHALL PROVIDE TENANT SPRINKLER SYSTEM SHUT-OFF VALVE AND VALVE TAMPER SWITCH AND COORDINATE ELECTRICAL REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. G. SPECIAL CONSIDERATION SHALL BE GIVEN TO AREAS THROUGHOUT THE BUILDING SUCH AS DROPPED SOFFITS, LIGHTING SOFFITS AND RECESSED STORAGE RACKS THAT NECESSITATE ADDITIONAL SPRINKLER HEADS. H. RUN PIPING HORIZONTALLY AND AT RIGHT ANGLES TO WALLS AND CEILINGS. CENTER SPRINKLER HEADS IN BOTH HORIZONTAL DIRECTION WITH RESPECT TO CEILING COMPONENTS, SUCH AS CEILING GRID, LIGHT FIXTURES, HVAC DIFFUSERS AND SPEAKERS OR AS DIRECTED BY OWNER'S REPRESENTATIVE. I. PROVIDE MAIN DRAINS AND AUXILIARY DRAINS WHERE NECESSARY. J. PROVIDE TEST CONNECTIONS AT MOST REMOTE POINT OF MAIN PORTION OF EACH SPRINKLER SYSTEM. K. LAYOUT THE SPRINKLER PIPING SO THAT THERE IS A MINIMUM SEPARATION OF 12" BETWEEN THE CEILING HEIGHT AND THE BOTTOM OF THE SPRINKLER PIPE OR ROUTE PIPING AROUND LIGHT FIXTURES TO AVOID CONFLICTS. L. ALL PIPING SHALL BE ROUTED IN THE SUSPENDED CEILING SPACE, CONCEALED IN WALLS AND BEHIND FIXED FURNISHINGS, UNLESS OTHERWISE INDICATED. ALL PIPING EXPOSED TO VIEW SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO THE UNDERSIDE OF THE STRUCTURE. M. REFER TO ARCHITECTURAL DRAWINGS OR CONSULT ARCHITECT FOR EXACT LOCATION OF FIXTURES, EQUIPMENT, ETC. AND FINAL FINISHED ELEVATIONS PRIOR TO ANY INSTALLATION WORK. N. EXISTING SYSTEMS THAT REQUIRE RELOCATION AND SERVE EXISTING FIXTURES OR EQUIPMENT OR AREAS THAT MUST REMAIN ACTIVE, SHALL BE RELOCATED DURING OWNER SCHEDULED SHUT -DOWNS. TEMPORARY CONNECTIONS AND EXTENSIONS OF REQUIRED SYSTEMS SHALL BE PROVIDED AS NEEDED AND AT THE CONTRACTOR'S EXPENSE. O. CONTRACTOR SHALL VISIT THE SITE AND DOCUMENT EXISTING CONDITIONS WITHIN THE LIMITS OF DEMOLITION, PRIOR TO START OF ANY WORK. FORWARD TO ARCHITECT/ENGINEER, FOR REVIEW, ONE (1) COPY OF EQUIPMENT AND SYSTEMS BEING REMOVED BY DEMOLITION WORK AND NEW INSTALLATION WORK. LIMITS OF DEMOLITION AREA SHALL BE AS INDICATED ON DRAWINGS PREPARED BY THE ARCHITECTURAL CONSULTANT. P. CAREFULLY REVIEW THE INTERIOR DESIGN, ARCHITECTURAL, STRUCTURAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL ITEMS TO BE REMOVED, RELOCATED, OR ACCOMMODATED; INCLUDE ALL COSTS IN BASE BID FOR THIS WORK. Q. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING DUCTWORK SHOP DRAWINGS FROM HVAC CONTRACTOR AND COORDINATING ROUTING OF SPRINKLER PIPING. ANY RELOCATION REQUIRED BY FIRE PROTECTION CONTRACTOR'S FAILURE TO COORDINATE SHALL BE DONE AT NO COST OR DELAY TO THE OWNER. R. DRAINING AND REFILLING OF SYSTEMS AS REQUIRED FOR DEMOLITION AND/OR NEW INSTALLATIONS WORK, SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR. MINIMIZE ANY AND ALL SHUTDOWNS OF THE FIRE PROTECTION SYSTEM. WHEN REQUESTING A SHUTDOWN, GIVE PROPER NOTICE TO OWNER WHEN MAKING SHUTDOWNS AND PAY ANY FEES REQUIRED, PERFORM ANY DUTIES REQUIRED BY OWNER WHEN MAKING A SHUTDOWN, FILL OUT A SHUTDOWN NOTICE FORM ANSWERING ALL ITEMS REQUESTED SUCH AS TIME AND LOCATION OF SHUTDOWN, SYSTEMS AFFECTED, AREAS AFFECTED, ETC.. PROVIDE FIRE WATCH AS REQUIRED DURING A SHUTDOWN. DURATION OF SHUTDOWNS SHALL BE KEPT TO A MINIMUM. IN NO CASE SHALL THE FIRE PROTECTION SYSTEM BE SHUTDOWN DURING OFF HOURS OF WORK DAY WITHOUT A FIRE WATCH. SYSTEM SHALL BE RETURNED TO NORMAL OPERATING CONDITIONS AT END OF WORK DAY. S. ALL SPRINKLERS IN CEILINGS SHALL BE RECESSED PENDENT HEADS OF WHATEVER TYPE AND FINISH APPROVED BY THE ARCHITECT AND CONSTRUCTION MANAGER. ALL SPRINKLERS IN OPEN CEILING AREA SHALL BE UPRIGHT PENDENT TYPE OF FINISH APPROVED BY THE ARCHITECT AND CONSTRUCTION MANAGER. EXACT LOCATIONS OF EACH AND EVERY SPRINKLER WILL BE APPROVED BY THE ARCHITECT AND CONSTRUCTION MANAGER. SUBMIT PRODUCTS AND SPRINKLER LOCATIONS TO THE ARCHITECT AND CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO THE SHOP DRAWING PROCESS. T. THE FIRE PROTECTION CONTRACTOR SHALL PERFORM A FLOW TEST. INFORMATION FROM THE CONTRACTOR'S FLOW TEST SHALL BE USED FOR THE CONTRACTOR'S HYDRAULIC CALCULATIONS AND SHALL INCLUDE A 10%SAFETY FACTOR. U. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE EXCEPT IN HIGH TEMPERATURE AREAS. CODED NOTES: O l . MODIFY THE EXISTING F.P. SPRINKLER INSTALLATION WITHIN THIS SPECIFIC AREA AS REQUIRED BY THE NEW ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL LAYOUT. THIS INCLUDES, BUT IS NOT LIMITED TO, REVISING THE EXISTING SPRINKLER PIPING LAYOUT AS REQUIRED BY INSTALLATION OF NEW WORK, AS WELL AS THE COORDINATION OF NEW SPRINKLER HEADS AND THE REVISED/NEW SPRINKLER PIPING LAYOUT WITH BOTH EXISTING AND NEW DUCTWORK, AIR DEVICES, LIGHTING, SPEAKERS, CEILING FEATURES, AND STRUCTURAL MEMBERS. PROTECTION/ COVERAGE TO BE PER NFPA PAMPHLET 13 ORDINARY HAZARD OCCUPANCY REQUIREMENTS. 2. MODIFY THE EXISTING F.P. SPRINKLER INSTALLATION WITHIN THIS SPECIFIC AREA AS REQUIRED BY THE NEW ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL LAYOUT. THIS INCLUDES, BUT IS NOT LIMITED TO, REVISING THE EXISTING SPRINKLER PIPING LAYOUT AS REQUIRED BY INSTALLATION OF NEW WORK, AS WELL AS THE COORDINATION OF NEW SPRINKLER HEADS AND THE REVISED/NEW SPRINKLER PIPING LAYOUT WITH BOTH EXISTING AND NEW DUCTWORK, AIR DEVICES, LIGHTING, SPEAKERS, CEILING FEATURES, AND STRUCTURAL MEMBERS. PROTECTION/ COVERAGE TO BE PER NFPA PAMPHLET 13 LIGHT HAZARD OCCUPANCY REQUIREMENTS. THIS DRAWING IS NOT BEING SUBMITTED FOR PLAN APPROVAL PURPOSES THIS PLAN IS PREPARED TO ASSIST FIRE PROTECTION (SUB) CONTRACTORS IN SUBMITTING A BID. SUCCESSFUL LICENSED FIRE PROTECTION (SUB)CONTRACTOR SHALL PREPARE DETAILED CONSTRUCTION DRAWINGS, PERFORM DETAILED HYDRAULIC FLOW CALCULATIONS, PAY FOR PLAN APPROVAL FEES, OBTAIN PERMITS, AND SUBMIT DOCUMENTS TO AUTHORITY(IES) HAVING JURISDICTION FOR REVIEW. Ln Ln p r- ro N N r- �m0000 . .� =3 O 00 00 > cn ._ C �O L vi lfl lD X Ln a) ro Ln E *� 00 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE+ PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z W G L.ii W N \ O = 0 5� G Z) Co 0 2 Oo Z)o J Q zm0 J N M (Dw W JUG 2� ' as �z �o V) O'a '� Q zo M�z � m W Q U J W (D~ cn <Mq o � w Sao < < 00 rl U L rl PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 FLOOR PLAN FIRE PROTECTION SHEET: F P a 1 a 0 0 00 00 RELEASED IFCR CONSTRUCTION 5uud9ezttn cnmiplanum with 311l1se9ulations _ of State and lmeal Endes 0tp at Caimal ntro DATE: 03/07/18 Nick Mishler DEMOLITION AND FLOOR PLAN - MECHANICAL 1 /4"=1 '-0" FLOOR PLAN - PLUMBING 1 /4"=1-0" MECHANICAL CODED NOTES: (D 1. COMPLETELY DEMOLISH EXISTING RTU AND ALL ASSOCIATED CURBS AND ACCESSORIES. COORDINATE WORK WITH ELECTRICAL CONTRACTOR. REPAIR / MODIFY ROOF PENETRATION AS NECESSARY FOR NEW RTU-1 INSTALLATION. 2. PROVIDE NEW PACKAGED ROOFTOP UNIT (RTU-1)AND CURB PER SCHEDULE. PROVIDE WITH SPECIFIED ACCESSORIES AND ASSOCIATED ADDITIONAL ITEMS NEEDED FOR A COMPLETE INSTALLATION. COORDINATE NEW WORK WITH ELECTRICAL CONTRACTOR. ENSURE ROOFTOP PENETRATIONS ARE FLASHED / COUNTER -FLASHED AND SEALED WEATHER -TIGHT. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. REFER TO INSTALLATION DETAIL. 3. PROVIDE TRANSFER GRILLES (Gl) IN LAY -IN CEILING PER SCHEDULE FOR RETURN AIR TO RTU. 4. PROVIDE FULL-SIZED RETURN AIR DUCT DROP. 5. ENSURE UNDERCUT IN DOOR. 6. ABOVE CEILING IN DASHED OUTLINED AREA TO BE CONSIDERED PLENUM RETURN AREA. ALL MATERIALS TO BE INSTALLED IN THIS AREA MUST BE PLENUM -RATED. 7. EXHAUST FAN / LIGHT COMBINATION FIXTURE PROVIDED BY EC. MC TO PROVIDE 4" EXHAUST DUCT TO ROOF PENETRATION. ENSURE ROOF PENETRATION IS LOCATED AT LEAST 10' FROM NEAREST OUTDOOR AIR INTAKE. ENSURE ROOF PENETRATION IS SEALED WEATHER -TIGHT. PLUMBING CODED NOTES: O 1. PROVIDE 4" SANITARY CONNECTION INTO SPACE FROM EXISTING SANITARY MAIN OF EQUAL OR GREATER SIZE. VERIFY EXACT LOCATION, SIZE, AND INVERT AND FLOW OF CONNECTION POINT PRIOR TO BID. COORDINATE TRENCHING AND WITH GC AND LANDLORD. CUT, BACKFILL AND PATCH AS REQUIRED. 2. CONNECT NEW DCW SERVICE TO EXISTING 1" DCW ROUGH -IN. PROVIDE SHUT-OFF VALVE AT POINT OF CONNECTION. 3. PROVIDE NEW ELECTRIC WATER HEATER PER SCHEDULE. INSTALL ABOVE RESTROOM CEILING ON DRAIN PAN, AVOIDING RESTROOM EXHAUST FAN. PROVIDE FULL-SIZE INDIRECT HARD -PIPED RELIEF VALVE DRAIN TO MOP SINK WITH 3'' AIR GAP ROUTED CLOSE TO WALL AS POSSIBLE. 4. PROVIDE 3" VENT THROUGH ROOF FOR RESTROOM VENT. INSTALL PER DETAIL ON THIS SHEET, ENSURING AT LEAST 10' CLEARANCE FROM ANY OUTSIDE AIR INTAKE. VENT TO BE CPVC, PLENUM -RATED MATERIAL. 5. ABOVE CEILING IN DASHED OUTLINED AREA TO BE CONSIDERED PLENUM RETURN AIR AREA. ALL MATERIALS TO BE INSTALLED IN THIS AREA MUST BE PLENUM -RATED. 3'' VTR 2 -\ - � I 2" i 2" I LAV-1 �I CO-1 13„ - WC-1 4" 2" \�4 \ / MS-1 \ � ool 3„- CO -I SANITARY STACK - PLUMBING N.T.S. MECHANICAL ABBREVIATIONS (D) DEMOLITION DN DOWN (E) EXISTING EA EXHAUST AIR (F) FUTURE EFF EFFICIENCY (R) (RELOCATE) EXH EXHAUST AAV AUTOMATIC AIR VENT MFR MANUFACTURER AFF ABOVE FINISHED FLOOR N/A NOT APPLICABLE BAS BUILDING AUTOMATIC SYSTEM NTS NOT TO SCALE BDD BACKDRAFT DAMPER OA OUTSIDE AIR BFP BACKFLOW PREVENTER RA RETURN AIR BOB BOTTOM OF BEAM SA SUPPLY AIR BOD BOTTOM OF DUCT TCP TEMPERATURE CONTROL PANEL BOP BOTTOM OF PIPE TYP TYPICAL BOS BOTTOM OF STRUCTURE UNO UNLESS NOTED OTHERWISE MECHANICAL LEGEND SUPPLY DUCT UP GRILLE/REGISTER SUPPLY DUCT DOWN �� TURNING VANES RETURN DUCT UP L- VOLUME DAMPER RETURN DUCT DOWN OT THERMOSTAT SD SMOKE DETECTOR LINEAR DIFFUSER WITH FLEX CONNECTION N_ SPIN -IN WITH VOLUME DAMPER DIFFUSER WITH FLEX CONNECTION 450 RETURN DUCT TAP WITH VOL. DAMPER PLUMBING ABBREVIATIONS (D) DEMOLITION HP HORSEPOWER (E) EXISTING MS MOP SINK CAP CAPACITY N/A NOT APPLICABLE CFM CUBIC FEET PER MINUTE NTS NOT TO SCALE CO CLEANOUT PSI POUNDS PER SQUARE INCH DCW DOMESTIC COLD WATER TMV THERMOSTATIC MIXING VALVE DHW DOMESTIC HOT WATER TYP TYPICAL OF DEGREES FAHRENHEIT UNO UNLESS NOTED OTHERWISE FD FLOOR DRAIN V VENT GPH GALLONS PER HOUR VTR VENT THRU ROOF GPM GALLONS PER MINUTE WC WATER CLOSET PLUMBING LEGEND EXISTING SANITARY ---->*- BALANCING VALVE SAN SANITARY BALL VALVE ----GW---- GREASE WASTE �'�� CHECK VALVE - DOMESTIC COLD WATER CONNECT TO EXISTING - - - - DOMESTIC HOT WATER SOH- PLUG VALVE - - - - - DOMESTIC HOT WATER RETURN �� PRESSURE REGULATOR - - - - - VENT _C9 RELIEF VALVE 0__ PIPE TURNED UP SOLENOID VALVE C- PIPE TURNED DOWN STRAINER FLOOR PENETRATION MARKER Q WATER HAMMER ARRESTOR MECHANICAL GENERAL NOTES: 1. ALL WORK TO BE PERFORMED TO MEET ALL STATE, CITY & LOCAL CODE REQUIREMENTS. 2. ALL ROOF CUTTING AND PATCHING TO BE BY THE GENERAL CONTRACTOR.. 3. HVAC CONTRACTOR IS TO COORDINATE WITH OTHER TRADES BEFORE INSTALLING DUCTWORK. IF THE HVAC CONTRACTOR FAILS TO COORDINATE WITH OTHER TRADES AND THE WORK MUST BE ALTERED THE HVAC CONTRACTOR WILL CHANGE IT AT HIS OWN EXPENSE. 4. ONCE THE SYSTEM IS COMPLETE THE AIR SIDE SHALL BE BALANCED. 5. COORDINATE THE EXACT LOCATION OF ALL GRILLES, REGISTERS & DIFFUSER WITH ARCHITECTURAL REFLECTED CEILING PLAN. ALSO COORDINATE MOUNTING HEIGHTS OF FIXTURES. 6. HVAC CONTRACTOR IS TO SUBMIT TO THE ARCHITECT FOR REVIEW ELECTRONIC COPY OF ALL EQUIPMENT & MATERIAL TO BE USED ON THE PROJECT. 7. HVAC CONTRACTOR IS TO VISIT THE SITE PRIOR TO SUBMITTING A BID & INCLUDE IN THE BID ANY ITEMS NECESSARY FOR A COMPLETE & OPERATIONAL SYSTEM. 8. DRAWINGS ARE SCHEMATIC IN NATURE & HVAC CONTRACTOR IS TO INCLUDE ANY ITEMS REQUIRED FOR A COMPLETE & OPERATIONAL SYSTEM WHETHER SHOWN OR NOT SHOWN ON THE DRAWINGS. 9. HVAC CONTRACTOR TO FURNISH ALL PERMITS REQUIRED FOR HIS PORTION OF THE WORK. FIELD VERIFY ALL CONDITIONS: DESIGN DRAWINGS ARE DIAGRAMMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. PLUMBING GENERAL NOTES: 1. ALL WORK TO BE INSTALLED TO MEET ALL STATE, CITY & LOCAL CODE REQUIREMENTS. 2. PLUMBING CONTRACTOR TO VISIT THE SITE PRIOR TO SUBMITTING BID, INCLUDE ANY ADDITIONAL ITEMS REQUIRED FOR A COMPLETE & OPERATIONAL SYSTEM. 3. PLUMBING CONTRACTOR TO FURNISH ALL PERMITS REQUIRED FOR THEIR WORK. 4. PLUMBING CONTRACTOR TO COORDINATE ALL WORK WITH OTHER TRADES. IF PLUMBING CONTRACTOR FAILS TO COORDINATE WITH OTHER TRADES AND WORK IS REQUIRED TO BE ALTERED, THE PLUMBING CONTRACTOR WILL BE RESPONSIBLE FOR THE WORK AT THEIR OWN EXPENSE. 5. VERIFY LOCATION, SIZE & INVERTS OF ALL UTILITIES PRIOR TO STARTING WORK. 6. ALL CUTTING OF EXISTING FLOORS, EXCAVATION & BACK FILL TO BE PART OF THE PLUMBING CONTRACTOR BID. PATCHING OF FLOORS & ROOF TO BE BY GENERAL CONTRACTOR. 7. COORDINATE ALL FLOOR PENETRATIONS WITH STRUCTURAL DRAWINGS. SET SLEEVES IN FLOORS AND WALLS AND ATTACHMENTS FOR HANGERS AS CONSTRUCTION PROGRESSES. ALL PENETRATIONS MUST BE SEALED AND HELD AS TIGHT TO COLUMNS OR WALLS AS POSSIBLE. 8. ALL PIPING SHALL BE CONCEALED INSIDE WALLS, BELOW FLOORS OR ABOVE CEILINGS UNLESS INDICATED OTHERWISE. 9. ALL PIPING SHALL BE SLOPED AS PER THE MINIMUM GRADE REQUIRED BY CODE (UNLESS NOTED OTHERWISE) FOR EACH PARTICULAR PIPE SIZE. 10. DO NOT RUN PLUMBING PIPING DIRECTLY ABOVE ELECTRICAL PANELS OR THROUGH OTHER WATER SENSITIVE AREAS. 11. ALL EQUIPMENT, PIPING, APPURTENANCES SHALL BE PROTECTED FROM DEBRIS AND DAMAGE. SENSITIVE EQUIPMENT SHALL NOT BE DELIVERED TO THE JOB SITE UNTIL IT IS TO BE INSTALLED. PIPING ENDS SHALL BE CLOSED BY TEMPORARY MEANS WHEN PORTIONS OF THE SYSTEM ARE NOT COMPLETE. 12. LOCATE ALL VALVES WHERE THEY ARE ACCESSIBLE FOR SERVICE AND USE. WHERE ACCESS PANELS ARE REQUIRED COORDINATE SELECTION AND LOCATION WITH ARCHITECT. 13. ALL PENETRATIONS AT FLOORS AND RATED PARTITIONS SHALL HAVE A UL CLASSIFIED FIRE STOP SYSTEM TESTED TO ASTM E814 AND UL 1497 BY UNDERWRITERS LABORATORIES. FIRE STOP SYSTEMS SHALL BE PROSET SYSTEMS, PENSIL FIRESTOP SYSTEMS OR 3M COMPANY. 14. PLUMBING CONTRACTOR TO COORDINATE WITH GC AND TENANT ON EXACT LOCATION OF ROUGH -INS. 15. PLUMBING CONTRACTOR TO VERIFY INVERT OF ALL TIE-IN POINTS INDICATED ON PLAN PRIOR TO INSTALLATION. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY IF EXISTING INVERT WILL BE INSUFFICIENT. DRAWING INDEX M1.1 MECHANICAL AND PLUMBING PLAN M2.1 MECHANICAL AND PLUMBING SCHEDULES AND DETAILS M3.1 PLUMBING SPECIFICATIONS M3.2 MECHANICAL SPECIFICATIONS M3.3 I MECHANICAL SPECIFICATIONS ro N N r- M 00 00 . .� =3 O 00 00 > cn ._ �O L vi lfl lD t]A � Ln Ln E +' 4-- 00 =5 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE+ PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z W 75; Lr) W N O = O Z) - Co 0 2 Oo Z)O J Q zmo J N M (Dw W JUG 2� ' as �z �o V) O'�'a Q zo ��z 0m W Q U J W (D~ V) v02 <M< V)w Sao < 00 rl U L rl PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 MECHANICAL AND PLUMBING PLAN SHEET: PACKAGED ROOFTOP UNIT SCHEDULE BASED ON TRANE U.N.O UNIT DATA PERFORMANCE DATA COOLING DATA HEATING DATA ELECTRCIAL DATA NOMINAL EFFICIENCY TOTAL MIN. OA ESP TOTAL SENSIBLE E.A.T (°F) INPUT OUTPUT TAG MODEL FAN (HP) REFRIG. FUEL TYPE VOLT PH MCA MOCP WEIGHT COMMENTS TONS (SEER) CFM CFM (IN. WC) MBH MBH DB/WB (kW) (MBH) RTU-1 THC036E3EGA 3 15.0 1200 360 0.4 1.0 38.5 27 80° / 67° R410-A 18 (3PH) 61.47 ELECTRIC 208 3 51.6 60 1000 LB 1-5 COMMENTS: 1. HAIL GUARD 4. FACTORY PROVIDED ENTHALPY ECONOMIZER AND BAROMETRIC RELIEF 2. 14" ROOF CURB 5. PROVIDE WITH DIGITAL PROGRAMMABLE THERMOSTAT 3. FACTORY PROVIDED DISCONNECT TAG -NECK SIZE CFM GRILLES, REGISTERS, AND DIFFUSERS SCHEDULE D = DIFFUSER G=GRILLE R=REGISTER BASED ON TITUS U.N.O. UNIT DATA PERFORMANCE DATA TAG FUNCTION MODEL FACE SIZE FRAME TYPE MATERIAL FINISH BALANCE DAMPER MAX N.C. COMMENTS D1 SUPPLY OMNI 24"x 24" LAY -IN ALUMINUM STANDARD - 25 1,2 G1 RETURN 50F 24"x 24" LAY -IN ALUMINUM STANDARD - 25 NOTES: 1. ALL SUPPLY DIFFUSERS TO BE INSULATED VIA FACTORY SYSTEM. 2. MATCH DUCT SIZES WITH SIZES ON PLANS. EXHAUST FAN SCHEDULE BASED ON COOK U.N.O UNIT DATA PERFORMANCE DATA BELT OR TAG MODEL FUNCTION FAN TYPE CFM ESP COMMENTS DIRECT NUTONE 7 EF RESTROOM EXHAUST CEILING MOUNTED LIGHT / FAN 70 0.10 - 1,2 (PROVIDED BY BY EC) NOTES: 1. MC TO PROVIDE 4" EXHAUST DUCT TO ROOF 2. EXHAUST FAN / LIGHT COMBO TO BE PROVIDED BY ELECTRICAL CONTRACTOR VACUUM RELIEF VALVE t-DCW - - - O t-DHWR-y-FZ�HOly 'I"111lI-IHO� RP-1 T O ET-1 I = PROVIDE 4" DEEP OVERFLOW PAN AND DRAIN TO MOP BASIN PLUMBING FIXTURE SCHEDULE FIXTURE ACCESSORIES TAG ITEM MANUF. MODEL DCW DHW DRAIN VENT ITEM MANUF. MODEL DESCRIPTION WC-1 WATER CLOSET STANDARD 2467.016 1/2" - 3" 2" SEAT OLSONITE 95CTSS ADA COMPLIANT FLOOR MOUNTED WHITE VITREOUS CHINA TANK TYPE WATER CLOSET WITH ELONGATED SIPHON JET BOWL, PRESSURE - ASSISTED FLUSHING SYSTEM, 1.6 GPF, 16-1/2" RIM HEIGHT, CHROME FLUSH LEVER AND TANK WITH LOCKING COVER DEVICE (*: MODEL NUMBER TO VARY BASED ON FLUSH LEVER ORIENTATION). PROVIDE HEAVY-DUTY PLASTIC OPEN FRONTSEAT LESS COVER. PROVIDE TANK COVER LOCKS. PROVIDE CHROME PLATED BRASS LOOSE KEY ANGLE STOP WITH CHROME PLATED FLEXIBLE COPPER SUPPLY RISER. PROVIDE TANK WITH FLUSH LEVER ON WIDE SIDE OF ROOM. INSTALLATION TO COMPLY WITH ADA ACCESSIBILITY REQUIREMENTS. LOCKING COVER AMERICAN STD. *4142.6 LAV-1 LAVATORY KOHLER K-2084 1/2" 1/2" 1-1/2' 1-1/2" FAUCET MOEN 6190 ADA COMPLIANT WALL MOUNTED WHITE VITREOUS CHINA LAVATORY WITH SINGLE FAUCET HOLE AND OVERFLOW. PROVIDE LEAD FREE CHROME PLATED SINGLE LEVER SINGLE HOLE FAUCET WITH 0.5 GPM FLOW RATE, PROVIDE CHROME PLATED GRID STRAINER DRAIN WITH CHROME PLATED BRASS TAILPIECE. PROVIDE CHROME PLATED BRASS P-TRAP WITH CLEANOUT, WALL BEND AND WALL FLANGE. PROVIDE CHROME PLATED BRASS LOOSE KEY ANGLE STOP WITH CHROME PLATED FLEXIBLE COPPER SUPPLY RISERS. PROVIDE CHROME FINISH ASSE 1070 LISTED UNDER -SINK THERMOSTATIC MIXING VALVE SET AT 105°F. PROVIDE MOLDED VINYL SAFETY COVERS FOR ALL EXPOSED SUPPLY AND DRAIN PIPING BELOW LAVATORY. PROVIDE RIGID IN -WALL CONCEALED LAVATORY SUPPORT SYSTEM. INSTALLATION TO COMPLY WITH ADA ACCESIBILITY REQUIREMENETS. DRAIN K R 57248 TRAP McGUIGUI RE 8912CBEC0 SUPPLY McGUIRE LF2165LK TMV WATTS LFUSG-B-M2-SC PIPING COVER TRUEBRO LAV-GUARD 2 E-Z CARRIER ZURN Z1231 MS-1 MOP SINK MUSTEE 63M 1/2" 1/2" 3" 1-1/2" FAUCET T&S BRASS B-0665-BSTR FLOOR MOUNTED ONE-PIECE MOLDED HIGH IMPACT RESISTANT DURASTONE STRUCTURAL FIBERGLASS MOP SERVICE BASIN WITH INTEGRAL MOLDED -IN DRAIN AND REMOVABLE STAINLESS STEEL STRAINER. PROVIDE CHROME PLATED CAST BRASS SERVICE SINK FAUCET WITH COLOR -CODED METAL CROSS HANDLES, QUARTER -TURN CERAMIC DISC CARTRIDGES, INTEGRAL SERVICE STOPS, INTEGRAL CHECK STOPS, 6" CAST BRASS SPOUT WITH VACUUM BREAKER, 3/4" HOSE THREAD OUTLET, PAIL HOOK AND ADJUSTABLE WALL BRACE. INSTALL FAUCET AT36" ABOVE FINISH FLOOR. PROVIDE HEAVY-DUTY STAINLESS STEEL WALL MOUNTED HOSE BRACKET. HOSE BRACKET MUSTEE 65.700 PLUMBING EQUIPMENT SCHEDULE TAG ITEM MANUFACTURER MODEL NO. COMMENTS ELECTRIC DOMESTIC WATER ELECTRIC DOMESTIC WATER HEATER, ETL LISTED. 3500 W, 30 GAL CAPACITY, 14 GPH RECOVERY RATE @ 100' F EWH-1 gRADFORD WHITE LE130L3-3 HEATER TEMPERATURE RISE. PROVIDE WITH DRAIN PAN AND DRAIN TO MOP SINK BELOW. ALL BRASS BODY TRAP PRIMER VALVE, PRESSURE DROP OF 5 - 10 PSIG OPENS VALVE, OPERATING RANGE: 35 - 75 PSIG, TP-1 TRAP PRIMER PRECISION PLUMBING PR-500 1/2" MALE NPT INLET CONNECTION, 1/2" FEMALE NPT OUTLET CONNECTION. DRAIN AND CLEANOUT SCHEDULE TAG ITEM MANUFACTURER MODEL NO. COMMENTS CAST IRON FLOOR DRAIN WITH SECONDARY DRAINAGE/ANCHOR FLANGE, WEEPHOLES, ADJUSTABLE FRAME AND GRATE WITH POLISHED FD-1 FLOOR DRAIN ZURN ZN-415 NICKEL BRONZE FINISH, 6" DIAMETER ROUND TOP WITH SQUARE OPENINGS AND BOTTOM GASKET CONNECTION OUTLET. CAST IRON BODY ADJUSTABLE CLEANOUT WITH ANCHOR FLANGE, POLISHED NICKEL BRONZE ROUND SCORIATED FRAME AND TOP, AND co-] FLOOR CLEANOUT ZURN ZN-1400 BOTTOM GASKET CONNECTION OUTLET. �Z�Z�1�1�►[eZK�71_��7:711Vr DRAIN LINE SAME SIZE AS NIPPLE ON DRAIN PAN CAPPED TEE FOR CLEANOUT 2"MIN. a rn N RELEASED IFCR CONSTRUCTION rsahiedtogumplanum with 311llsegulmums _ u95tate and Ilocal Endles 0tp at Cairemal ntro DATE: 03/07/18 Nick Mishler RTU ROOF CU ROOF `PRIME TRAP BEFORE UNIT START-UP A(IN) B(IN) DRAWTHRU COIL FAN INLET STATIC "A" /2+1 RTU CONDENSATE DRAIN DETAIL N.T.S SUPPORT BY GC BURNER THERMOSTAT AND PRESSURE REGULATOR FURNISHED WITH WATER HEATER CEILING SIZED WITH AGA/CGA TEMPERATURE STEAM RATING 10% OVER HEATER INPUT PROVIDE A HARD COPPER RELIEF VALVE COPPER DISCHARGE LINE. FULL SIZE OF VALVE OUTLET TO END OVER TO MS-1 WITH AN AIR GAP 2 TIMES THE PIPE DIAMETER. �---DCW -�--Z I _--AUTOMATIC TRAP PRIMER VALVE DRAIN VALVE. ROUTE 1" DRAIN LINE TO MOP BASIN BELOW FINISHED FLOOR REFER TO SPECIFICATIONS AND PLUMBING FIXTURE SCHEDULE. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO FLOOR PLAN FOR PIPE SIZES. SET WATER HEATER THERMOSTAT AT 140°F. PROVIDE SEISMIC STRAP OR BRACING AND FLEXIBLE CONNECTORS TO WATER AND GAS CONNECTIONS IF/AS REQUIRED BY LOCAL AUTHORITIES. ELECTRIC WATER HEATER DETAIL N.T.S. WOOD DECK WOOD BEAM FLAT WASHER THROUGH BOLT --- TOP BEAM C-CLAMP IF STEEL BAR JOIST ADJUSTABLE BAND HANGER FOR PIPING FOUR INCH OR LESS DO NOT HANG PIPE FROM BOTTOM OF JOISTS STRUCTURAL ANGLE DOUBLE NUT ATTACHMENT /-ALL -THREAD ROD. — LENGTH AS REQUIRED FOR PIPE SLOPE PROVIDE COPPER OR NON-METALLIC COATING WHERE HANGERS CONTACT BARE COPPER PIPE CLEVIS HANGER FOR PIPE OVER FOUR INCH PROVIDE A ONE FOOT LENGTH OF NON -COMPRESSIBLE INSULATION AT HANGERS FOR ALL PIPE 2" AND LARGER PROVIDE GALVANIZED STEEL SADDLE FOR ALL INSULATED PIPE LARGER THAN 3/4''. VERIFY INSULATION THICKNESS WHEN SIZING HANGERS PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: COPPER: 4''=12'; 3''=1 1'; 2-1 /2"=10'; 2"=9'; 1-1 /2''=8'; 1-1 /4''=7', 1"=6', 3/4''=6', 1 /2"=5'. CAST IRON: 10' AND ONE NEAR ALL JOINTS. STEEL: 4"=14'; 3"=12'; 2-1 /2"=1 l'; 2''=10'; 1-1 /2''=9'; 1 '=7; 3/4"=6'; 1 /2"=5'. LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT ACCEPTABLE. REFER TO CODES AND SPECIFICATIONS FOR FURTHER INFORMATION. PIPE HANGER DETAIL N.T.S. GASKET (SUPPLIED WITH CURB) FACTORY FABRICATED ROOF CURB z 1� I ROOF FLASHI EXISTING STRUCTURE INDOOR DUCT INSULATIO PACKAGED ROOFTOP UNIT FLEXIBLE DUCT CONNECTION DUCTWORK EXPANDING POLYURETHANE FOAM INSUL. AROUND PERIM. OF DUCT IN METAL DECK NOTES: PLANE 1. IN -FILL BETWEEN EQUIPMENT CURB AND DUCTWORK, ALL SIDES WITH BATT. INSULATION (TYP.). PACKAGED ROOFTOP UNIT DETAIL N.T.S COVER VALVE BODIES WITH - INSULATION, BUT NOT UNIONS DISTRIBUTION UNIT IF 2 OR MORE FLOOR DRAINS ARE BEING FED FROM ONE TAP Ifilm lulml 1/2" TYPE X" COPPER TUBING I I PIPING ROUTED IN WALLS WHEN APPLICABLE. SLEEVE PIPING BELOW CONCRETE SLAB. SLOPE TO DRAIN TRAP PRIMER DETAIL N.T.S. FLOOR DRAIN SANITARY PIPING ROOF STRUCTURE SHOWN FOR REFERENCE ONLY. REFER TO PIPE HANGER DETAIL. TAPE JOINTS MITER THE INSULATION AT TEES AND ELBOWS FIBERGLASS INSULATION SO THAT THERE ARE NO GAPS AT JOINTS. PROVIDE ONE-PIECE PRE -MOULDED PVC PROVIDE A ONE FOOT LENGTH OF FITTING COVERS NON -COMPRESSIBLE INSULATION AT HANGERS FOR ALL PIPE 2'' AND LARGER PROVIDE INSULATION ON DOMESTIC HOT/COLD WATER PIPES, STORM WATER REFER TO OTHER DETAILS FOR TREATMENT PIPES, AND CONDENSATE DRAIN PIPING IN OF INSULATION AT PENETRATION OF WALLS AND CHASES WALLS AND FIREWALLS a a , n a a PROVIDE FIBERGLASS INSULATION WITH ALL -SERVICE JACKET WITH VAPOR BARRIER ON ALL COLD/HOT WATER PIPING AND CONDENSATE DRAIN PIPE. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURERS INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT AND TAPE. FLAME -SPREAD AND SMOKE -DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. PIPE INSULATION DETAIL N.T.S. NOTE: VENT TO BE LOCATED NO LESS THAN 12'-0'' HORIZONTALLY FROM ANY BUILDING FRESH AIR INTAKE AND NO LESS THAN 3'-0'' VERTICAL ABOVE ANY BUILDING FRESH AIR INTAKE. ----------- STAINLESS STEEL CLAMP NOTE: ALL CUTTING, FLASHING AND SEALING OF ROOF SHALL BE DONE BY 00 N LANDLORD'S ROOFING CONTRACTOR AT I r THIS CONTRACTOR'S EXPENSE. ROOF RIGID INSULATION ROOF DECK PIPE CLAMP ANCHOR TO MEDIUM EXPANSION CLIP ANGLE INSULATING FOAM INSTALL 1/2" THICK FIBERGLASS INSULATION TO REFER TO PLANS FOR FIRST 90 EIBON OR A MAX EXACT SIZE AND LOCATION OF 5-2" VERT VENT THROUGH ROOF DETAIL N.T.S. > 01 c-I r- r- � N N r- r- N M 00 00 . .� =5 O 00 00 > L =; _ _ �0 L av m Ln E +� 4 00 =3 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z W 2 Ln N \W O = 0 Z) Co 0 G Oo Z) J o Q z J Co N M (D w Q w w ILu �V) JQQ Q=z Q a-o Q L1J ~ Io z 0 ro �z �Co = W j J z Vow Qrn� =a Vw ��Q0Q00 PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 MECHANICAL AND PLUMBING SCHEDULES AND DETAILS SHEET: M2ol SPECIFICATIONS - DIVISION 22 - PLUMBING GENERAL CONDITIONS SERVICE/TRANSMISSION MEDIUM (WATER, AIR, GAS, ETC.) AND METHODS OF INSTALLATION (AS APPLICABLE), AND SHALL BE SO LISTED. FINAL APPROVAL FOR USE IS SUBJECT TO THE REQUIREMENTS OF THE REVIEW AND h. HANGER RODS MUST BE PERPENDICULAR BEFORE INSULATION IS INSTALLED. WATER HAMMER ARRESTORS A. GENERAL INSPECTION AUTHORITIES: BUILDING SOIL, WASTE AND VENT SYSTEM 1. SIMILAR TO ZURN SHOCKTROL SERIES Z-1700, SIZED AND INSTALLED AS RECOMMENDED BY THE MANUFACTURER 1. THIS CONTRACT SHALL INCLUDE A VISIT TO THE JOB SITE AND TAKE INTO CONSIDERATION MECHANICAL, a. CAST IRON PIPE, FITTINGS AND JOINING METHODS; PER APPLICABLE ASTM/ANSI/ASME/CISPI STANDARDS. 1. APPLICATIONS FOR SANITARY AND VENT SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: FOR SPECIFIC CONDITIONS AT EACH LOCATION. ELECTRICAL AND GENERAL TRADE WORK IN PLACE AND WORK TO BE PUT INTO PLACE PRIOR TO BIDDING. REROUTING OF DUCTWORK, PIPING, AND EQUIPMENT, AS REQUIRED TO MISS THIS WORK SHALL BE b. COPPER/COPPER ALLOY/BRASS PIPE/TUBE, FITTINGS AND JOINING METHODS; PER APPLICABLE a. SANITARY AND VENT PIPING FROM DESIGNATED POINTS WITH ALL CONNECTIONS. 2. EQUAL SHOCK ABSORBERS AS MANUFACTURED BY J.R. SMITH, JOSAM, SIOUX CHIEF OR PRECISION PLUMBING ACCOMPLISHED AT NO ADDITIONAL COST TO THE OWNER. ASTM/ANSI/ASME STANDARDS. IN ADDITION, WHERE UTILIZED FOR POTABLE WATER SERVICE, ALL ELEMENTS PRODUCTS MAY BE PROVIDED AT THE CONTRACTOR'S OPTION. SHALL BE PER APPLICABLE NSF STANDARDS. b. DRAINAGE AND VENT PIPING FOR ALL OTHER MISCELLANEOUS SYSTEMS OR EQUIPMENT AS INDICATED ON DRAINS, CLEANOUTS, AND DRAINAGE SPECIALTIES B. SCOPE OF WORK DOCUMENTS AND AS REQUIRED. 4. ALL PLUMBING CONTRACT ITEMS/ELEMENTS SHALL HAVE THE MANUFACTURER'S MARK OF NAME AND THE 1. GENERAL 1. THE WORK INCLUDES MODIFICATION TO THE EXISTING PLUMBING SYSTEM AND PROVIDING NEW MATERIALS, QUALITY OF THE PRODUCT OR IDENTIFICATION OF SAME CAST, EMBOSSED, STAMPED OR INDELIBLY MARKED ON c. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SANITARY PIPING FINAL CONNECTIONS AND ALL FITTINGS AND ACCESSORIES NECESSARY FOR A COMPLETE FUNCTIONING PLUMBING SYSTEM. THE WORK ALSO EACH ITEM/ELEMENT IN ACCORDANCE WITH THE STANDARDS UNDER WHICH THEY ARE ACCEPTED AND INDIRECT PIPING FROM EQUIPMENT TO DRAIN TO COMPLETE THE SANITARY WASTE AND VENT PIPING SYSTEM e. FURNISH AND INSTALL DRAINS, CLEANOUTS AND DRAINAGE SPECIALTIES AS INDICTED ON THE DRAWINGS, INCLUDES ROUGH -IN AND FINAL CONNECTIONS TO EQUIPMENT PROVIDED BY OTHERS. ALL WORK SHALL BE IN APPROVED PER APPLICABLE CODE(S). AND TO COMPLETE THE INDIRECT DRAINAGE PIPING SYSTEM TO OPERATE ALL EQUIPMENT AND FIXTURES AND ELSEWHERE AS REQUIRED FOR COMPLETE DRAINAGE, ACCESS AND SPECIAL FUNCTION/OPERATION AT ACCORDANCE WITH OWNER'S REQUIREMENTS, STATE AND LOCAL CODES AND/OR ORDINANCES AND IS PROPERLY. ALL ITEMS/ELEMENTS AND AREAS REQUIRING SAME AND FOR PROPER INTEGRATION WITH THE BUILDING SUBJECT TO INSPECTION. 5. PLUMBING UTILITY CONNECTIONS PROVIDE FOR ITEMS OR ELEMENTS NOT INCLUDED IN THE PLUMBING DRAINAGE SYSTEM. CONTRACT. 2. SCOPE 2. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, TOOLS, INCIDENTALS, DETAILS, ETC. NECESSARY TO f. UNLESS INDICATED OTHERWISE, ALL ITEMS/ELEMENTS AND THEIR COMPONENT PARTS DESCRIBED HEREIN TO PROVIDE A COMPLETE, OPERATIONAL AND APPROVED PLUMBING SYSTEM, INCLUDING BUT NOT LIMITED TO ALL a. UNLESS INDICATED OTHERWISE, THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL TRAPS AND a. FURNISH A COMPLETE SYSTEM OF INTERIOR SOIL WASTE DRAINAGE (INCLUDES SANITARY AND VENT PIPING) BE OF METALLIC CONSTRUCTION WHEN SUCH IS AVAILABLE FOR THE BASE SPECIFIED ITEM/ELEMENT. USE OF ITEMS AND ELEMENTS DESCRIBED IN THE PLUMBING SPECIFICATION AND SHOWN ON THE PLUMBING DRAWINGS, STOPS (AS APPLICABLE) AS REQUIRED FOR ITEMS FURNISHED UNDER SEPARATE CONTRACT. THIS INCLUDES FROM BUILDING FIXTURES, EQUIPMENT, AND ANY OTHER ELEMENTS REQUIRING THE SAME. PLASTIC, COMPOSITE, OR OTHER NON-METALIC COMPONENTS AND/OR MATERIALS BY LISTED ALTERNATE AND AS REQUIRED FOR COORDINATION AND/OR INTERFACE WITH WORK UNDER SEPARATE CONTRACT AS ITEMS WITH CONNECTIONS BY THE PLUMBING CONTRACTOR OR WITH CONNECTIONS UNDER SEPARATE 3. PRODUCTS ITEMS/ELEMENTS IS PROHIBITED. INDICATED BY COMPLETE CONSTRICTION DOCUMENTATION PACKAGE. CONTRACT. a. DRAINAGE WASTE AND VENT (DWV) PIPING TO BE AS FOLLOWS (INCLUDES SANITARY, VENT, STORM & 2. PRODUCTS 3. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR SATISFACTORILY ADDRESSING ALL REVIEW AND INSPECTION b. UNLESS INDICATED OTHERWISE, FIXTURE TRAPS ABOVE FLOOR SLAB CONNECTED TO THE SANITARY WASTE GREASE WASTE): AUTHORITIES REQUIREMENTS AND DIRECTIVES IN REGARD TO METHODS OF INSTALLATION NECESSARY FOR FINAL SYSTEM SHALL BE CAST BRASS P-TRAPS WITH INTEGRAL CLEANOUT. P-TRAPS BELOW FLOOR SLAB TO BE CAST a. THIS CONTRACTOR MAY, AT HIS OPTION, USE ABS PLASTIC PLUGS IN LIEU OF BRONZE PLUGS WHERE APPROVAL. IRON, LESS CLEANOUT. SEE DRAWINGS FOR SIZES. 1. ASTM A 74, CISPI HS 74 CAST IRON SERVICE WEIGHT HUB AND SPIGOT PIPE AND FITTINGS WITH NEOPRENE SPECIFIED, EXCEPT ABS PLUGS SHALL NOT BE PERMITTED IN RETURN AIR PLENUMS OR AT EXPOSED GASKETS OR ASTM A 888, CISPI 301 CAST IRON SERVICE WEIGHT HUBLESS PIPE AND FITTINGS WITH ASTM C LOCATIONS. LOCATION OF THE RETURN AIR PLENUM TO BE CONFIRMED WITH THE HVAC CONTRACTOR. C. SUBSTITUTIONS AND MISCELLANEOUS EQUIPMENT c. UNLESS INDICATED OTHERWISE, FIXTURE TRAPS CONNECTED TO WASTE OR DRAIN SYSTEMS OTHER THAN THE 1277, CISPI 310 HUBLESS COUPLINGS. HUBLESS COUPLINGS TO BE INSTALLED ABOVE GRADE ONLY. SANITARY WASTE SYSTEM SHALL BE OF THE SAME MATERIAL AND CONSTRUCTION TYPE AS THE ASSOCIATED b. EQUAL DRAINS, DRAINAGE SPECIALTIES AND CLEANOUTS AS MANUFACTURED BY ZURN, ZURN LC, JOSAM, 1. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED PIPING SYSTEM. P-TRAPS TO BE PROVIDED AS INDICATED ON THE DRAWINGS. 2. ASTM D 2665, SCHEDULE 40 TYPE 1, GRADE 1 PVC DWV PIPE AND ASTM D 2665, MADE TO ASTM D 3311, SIOUX CHIEF, WATTS, JRS PRODUCTS, OR J.R. SMITH MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. HEREIN. WHERE ONE OR MORE NAMES OF MANUFACTURERS ARE MENTIONED ANY ONE MAY BE UTILIZED. FITTINGS WITH ASTM F 656 ADHESIVE PRIMER AND ASTM D 2564 SOCKET SOLVENT SOLDER JOINTS AND 2. ALTERNATIVE EQUIPMENT MAY BE BID AS A SUBSTITUTION TO THAT SPECIFIED WITH THE APPROPRIATE DEDUCT d. UNLESS INDICATED OTHERWISE, SUPPLY ROUGH -INS TO BE FURNISHED WITH ACCESSIBLE SHUT OFFS AT CONNECTIONS. PLASTIC PIPING NOT PERMITTED FOR INSTALLATION IN RETURN AIR PLENUMS OR 3. EXECUTION NOTED. HOWEVER; THE EQUIPMENT SUBSTITUTED SHALL MEET ALL SPECIFICATIONS IN DESIGN AND BE SUBJECT TO CONNECTIONS POINTS. SHUT OFFS AT SUPPLY ROUGH -INS FOR FIXTURES (SINKS, LAVATORIES, ETC.) TO BE LOCATIONS EXPOSED TO RETURN AIR PLENUMS. a. PROVIDE A COMPATIBLE FASTENING ASSEMBLY WITH INTERNAL SECONDARY DRAINAGE FLANGE AND OWNER AND/OR ENGINEER APPROVAL. ANY ADDITIONAL COST INCURRED DUE TO SUBSTITUTION SHALL BE THE ANGLES TYPE COMPRESSION STOPS. SHUT OFFS AT SUPPLY ROUGH -INS FOR EQUIPMENT OF OTHER ELEMENTS WEEPHOLES FOR ALL ITEMS SPECIFIED HEREIN BEING INSTALLED IN STRUCTURES HAVING A WATER PROOF RESPONSIBILITY OF THE CONTRACTOR AT NO EXPENSE TO THE OWNER. TO BE IN -LINE VALVES AS SPECIFIED FOR INDIVIDUAL SERVICES. 4. EXECUTION MEMBRANE, FLASHING, VAPOR BARRIER, OR SIMILAR ELEMENT PROVIDED UNDER SEPARATE CONTRACT. e. UNLESS INDICATED OTHERWISE, WHERE CONNECTION ELEMENTS DESCRIBED HEREIN ARE EXPOSED IN a. ALL CAST IRON SOIL PIPE SHALL BE BITUMASTIC COATED INSIDE AND OUTSIDE. ALL CAST IRON PIPING INSTALLATION CONDITIONS TO BE VERIFIED FROM ARCHITECTURAL DOCUMENTATION AND COORDINATED 3. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE PIPING SYSTEMS SUCH AS FITTING, HANGERS, ETC., CAN LOCATIONS OTHER THAN THE RESTRICTED ACCESS UTILITY OR MAINTENANCE AREAS, ALL METALLIC (INCLUDING JOINTS AND CONNECTIONS) SHALL BE INSTALLED IN ACCORDANCE WITH STANDARDS AS SET WITH THE APPROPRIATE CONTRACTOR. BE OF ANY RECOGNIZED MANUFACTURER PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET BY THE COMPONENTS TO BE FURNISHED WITH A POLISHED CHROME FINISH. WALL OR OTHER STRUCTURE PIPING FORTH BY THE CAST IRON SOIL PIPE INSTITUTE (CSPI). b. COUNTER FLASHING (WHEN REQUIRED) FOR ITEMS SPECIFIED HEREIN IS TO BE COMPATIBLE WITH ENGINEER. PENETRATIONS AT THESE LOCATION TO BE PROVIDED WITH POLISHED CHROME FINISH ESCUTCHEONS. b. AT THE CONTRACTOR'S OPTION, HUBLESS CAST IRON SOIL PIPE MAY BE JOINED BY USING HEAVY DUTY WATERPROOF MEMBRANE, VAPOR BARRIER, FLASHING, OR SIMILAR ELEMENTS PROVIDED UNDER SEPARATE D. DRAWINGS EXECUTION GENERAL "CLAMP ALL" COUPLINGS IN LIEU OF "NO -HUB" COUPLINGS. COUPLINGS ARE TO BE MADE OF 24 GAUGE CONTRACT AT THE INTERFACE POINT. COUNTER FLASHING TO BE PROVIDED AND SET IN PLACE BY THE 1. DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO SHOW THE APPROXIMATE LOCATION OF OUTLETS, TYPE 304 STAINLESS STEEL WITH HI -TORQUE CLAMPS AND NEOPRENE GASKETS. COUPLINGS SHALL BE PLUMBING CONTRACTOR. BUT WILL BE MADE WATERTIGHT BY THE CONTRACTOR INSTALLING THE EQUIPMENT AND PIPING. 1. WHERE STANDARDS, CODES OR GUIDELINES ARE REFERENCED HERIN AND THROUGHOUT THE PLUMBING INSTALLED AND TESTED IN ACCORDANCE WITH THE MANUFACTURE'S RECOMMENDATIONS. MEMBRANE, VAPOR BARRIER, FLASHING OR SIMILAR ELEMENTS PROVIDED UNDER SEPARATE CONTRACT. CONTRACT DOCUMENTATION, INCLUDING PLANS AND SPECIFICATIONS, THE LATEST VERSION/EDITION SHALL BE INSTALLATION CONDITIONS TO BE VERIFIED FROM ARCHITECTURAL DOCUMENTATION AND COORDINATED 2. THE EXACT LOCATION OF OUTLETS, EQUIPMENT AND PIPING MAY BE CHANGED FROM TIME TO TIME AS WORK APPLIED, UNLESS THE BUILDING CODE REFERENCES ANOTHER VERSION/EDDITION, WHICH SHALL TAKE c. PLASTIC PIPING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND WITH THE APPROPRIATE CONTRACTOR. PROGRESSES. UNDER THIS CONTRACT ALL LOCATIONS SHALL BE VERIFIED WITH ALL TRADES AND THAT THEY ARE PRECEDENCE. RECOMMENDATIONS, WITH PARTICULAR ATTENTION TO REQUIREMENTS FOR JOINING METHODS, SUPPORT, ACCORDING TO THE LATEST INFORMATION AVAILABLE. SHOULD THIS NOT BE DONE THE WORK WILL BE AND ALLOWANCES FOR EXPANSION AND CONTRACTION. PLASTIC PIPING SHALL NOT BE INSTALLED IN ANY c. THIS CONTRACTOR SHALL RESPONSIBLE FOR HAVING ALL DRAINS, CLEANOUTS AND OTHER ITEMS SO CHANGED AT NO ADDITIONAL EXPENSE TO THE OWNER. 2. REFER TO PROJECT DOCUMENTATION FURNISHED WITH THE COMPLETE CONSTRUCTION PACKAGE IN ADVANCE RETURN AIR PLENUM OR CHASE THAT IS USED FOR RETURN AIR. A NOTED INSTALLED FLUSH AND LEVEL WITH FINISH WALL, FLOOR ORR OTHER STRUCTURE AS APPLIES. OF WORK FOR OVERALL COORDINATION AND VERIFICATION OF REQUIREMENTS AT WORK OF OTHER TRADES COORDINATE INSTALLATION WITH CONTRACTOR'S PROVIDING ASSOCIATED STRUCTURE, INCLUDING 3. THE OWNER RESERVES THE RIGHT TO MAKE MINOR CHANGES IN LOCATION OF EQUIPMENT AND PIPING RELATING TO, INTERFACING WITH, AND/OR IMPACTING WORK IN THE PLUMBING CONTRACT. THIS INCLUDES d. COORDINATE INSTALLATION WITH STRUCTURE, EXISTING CONDITIONS AND WORK OF OTHER TRADES AT AND REQUIRED ELEVATIONS AND DIMENSIONAL LOCATIONS. ITEMS NOT PROPERLY INSTALLED SHALL BE REMOVED ARRANGEMENTS UP TO THE TIME OF ROUGH -IN WITHOUT ADDITIONAL COSTS TO THE OWNER. EXACT LOCATIONS, QUANTITIES, PHYSICAL SIZES, ROUGH -IN DETAILS, PIPE ROUTING, CONNECTION SIZES, ETC., ADJACENT TO SOIL, WASTE AND VENT SERVICE PIPING INSTALLATION. AND REPLACED TO THE SATISFACTION OF THE OWNERS' ON -SITE REPRESENTATIVE. FOR ITEMS INCLUDING BOTH IN THE PLUMBING CONTRACT AND UNDER SEPARATE CONTRACT. COORDINATE 4. THE DRAWINGS AND SPECIFICATION ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIALS OR INSTALLATION AND INTERFACE REQUIREMENTS WITH THE APPROPRIATE CONTRACTOR(S) IN ADVANCE OF DOMESTIC WATER PIPING SYSTEMS d. ALL ITEMS AND ACCESSORIES SPECIFIED HEREIN ARE TO BE INSTALLED IN ACCORDANCE WITH THE LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NO MENTIONED IN BOTH. ANY MATERIAL OR WORK. 1. GENERAL MANUFACTURER'S RECOMMENDATIONS, AND IN ACCORDANCE THE THE REQUIREMENTS OF THE LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS BUT WHICH IS INSPECTION/APPROVAL AUTHORITIES. OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR 3. INCLUDE ANY MINOR DETAILS, ITEMS AND/OR ELEMENTS ESSENTIAL TO NECESSARY APPROVALS AND a. THE DOMESTIC WATER PIPING SYSTEM SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: CHARACTER SHALL BE FURNISHED UNDER THIS CONTRACT. SUCCESSFUL OPERATION IN ADDITION TO THE ITEMS SPECIFIED HEREIN AND SHOWN ON THE DRAWINGS. e. WITH THE EXCEPTION OF CLEANOUTS, ALL ITEMS SPECIFIED ARE TO HAVE CONNECTION SIZE SAME AS 1. COLD WATER SUPPLY, HOT WATER SUPPLY. CONNECTED PIPING SIZE SHOWN ON THE DRAWINGS, UNLESS DIRECTED OTHERWISE. E. CLEANING UP 4. SEE GENERAL "PLUMBING NOTES" ON DRAWINGS FOR ADDITIONAL CONDITIONS AND REQUIREMENTS RELATIVE TO THE PLUMBING CONTRACT. 2. PRODUCTS f. CLEANOUTS ARE TO HAVE OUTLET SIZE, CONNECTION PIPE AND FITTINGS OF SAME SIZE AS SHOWN ON 1. UNLESS OTHERWISE NOTED, ALL EXCESS MATERIALS AND DEBRIS CAUSED BY THIS WORK SHALL BE COME THE PLANS FOR WASTE/DRAIN PIPING BEING SERVED, UP TO AND INCLUDING 3" SIZE. CLEANOUTS ARE TO HAVE PROPERTY OF THE CONTRACTOR AND PROMPTLY BE REMOVED FROM THE SITE. ALL FIXTURES AND EQUIPMENT 5. PLUMBING ITEMS AND ELEMENTS SHALL BE INSTALLED WITH DUE REGARD TO PRESERVATION OF THE STRENGTH a. PIPE AND FITTINGS. OUTLET SIZE, CONNECTING PIPE AND FITTINGS OF 4" SIZE WHEN SHOWN ON THE DRAWINGS SERVING INSTALLED SHALL BE THOROUGHLY CLEANED WEEKLY. ALL MOTORS AND EQUIPMENT SHALL BE COVERED OR OF STRUCTURAL MEMBERS AND PREVENTION OF DAMAGE TO WALLS, SURFACES AND OTHER STRUCTURES 1. ABOVE GROUND PIPING UP TO AND INCLUDING 3" SIZE TO BE ASTM B88, ANSI/NSF 61 TYPE L HARD WASTE/DRAIN PIPING 4" SIZE AND LARGER. OTHERWISE PROTECTED FORM CONSTRUCTION DUST AND DEBRIS. NO EQUIPMENT OTHER THAN THOSE THROUGH INSTALLATION, BEARING SUPPORT OF SUBSEQUENT USAGE OF PLUMBING ITEMS AND ELEMENTS. NO DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND SOCKET SOLDER JOINTS AND DESIGNED TO ARE TO BE EXPOSED TO INCLEMENT WEATHER. TOUCH UP ALL SCRATCHES AND REPAIR ANY DENTS FRAMING OR OTHER SUPPORT STRUCTURE SHALL BE CUT, NOTCHED OR BORED IN EXCESS OF LIMITATIONS CONNECTIONS. TEE DRILL MECHANICAL SADDLE CONNECTIONS MAY BE UTILIZED FOR BRANCH g• COORDINATE LOCATIONS OF ITEMS SPECIFIED HEREIN, AND INSTALLED IN OR AT STRUCTURE PROVIDED IN EQUIPMENT. SPECIFIED IN THE BUILDING CODE, OR BY THE MANUFACTURER OF THE FRAMING OR OTHER SUPPORT TAKE -OFFS. PIPING BELOW GRADE 2" DIAMETER AND SMALLER SHALL BE ASTM B88 LISTED/APPROVED TYPE UNDER SEPARATE CONTRACT, RELATIVE TO FOUNDATIONS, BEAMS AND OTHER STRUCTURE ELEMENTS TO STRUCTURE, AS CONFIRMED IN ADVANCE OF WORK BY THE PLUMBING CONTRACTOR. K SOFT COPPER TUBING IN A SINGLE LENGTH WITH NO IN -LINE COUPLINGS OR JOINTS. COMPLETED AVOID CONFLICTS. MAKE MINOR ADJUSTMENTS AS REQUIRED FOR PROPER INSTALLATION, CLEARANCE F. CUTTING AND PATCHING AND ACCESSIBILITY. REFER TO ARCHITECTURAL/STRUCTURAL DOCUMENTATION IN ADVANCE OF WORK AND SLEEVES INSTALLATION TO BE RATED 135 S.W.P AND 400 W.O.G. COORDINATE INSTALLATION WITH THE APPROPRIATE CONTRACTOR. 1. CUTTING FOR OPENINGS, WHEN NECESSARY, SHALL BE DONE BY THIS CONTRACTOR WITH SUCH TOOLS AND METHODS AS TO PREVENT UNNECESSARY DAMAGE TO SURROUNDING AREAS OR EQUIPMENT. 1. SLEEVE MATERIAL: BLACK STEEL PIPE, MACHINE CUT, LARGE ENOUGH TO ALLOW 1/4" CLEARANCE ALL AROUND 2. BALL VALVES 3" SIZE AND SMALLER SHALL BE LEAD-FREE TWO-PIECE BRONZE BODY BALL VALVE, SOLDERED PIPE AND PIPE COVERING. USE MACHINE CUT COPPER SLEEVES FOR NON -INSULATED COPPER PIPE. CONNECTIONS, UNION CONNECTION BODY, TEFLON SEATS, FULL PORT WITH BLOW OUT PROOF STEM, PIPE ANCHORS, HANGERS AND SUPPORTS 2. FILL SPACE IN ALL AREAS PACKING WHERE REQUIRED TO MAINTAIN FIRE RATING, OPENINGS SHALL BE ADJUSTABLE PACKING GLAND, CHROME PLATED BRONZE BALL AND LEVER HANDLE LABELED FOR THE TEMPORARILY FIRE STOPPED UNTIL PERMANENT FIRE STOPPING IS DONE. THIS INCLUDES HOLES LEFT DUE TO 2. SLEEVES IN PARTITIONS TO HAVE LENGTH EQUAL TO THE THICKNESS OF FINISHED PARTITIONS. SLEEVES IN FLOORS SERVICE CONTROLLED. DESIGN FOR 150 S.W.P. AND 400 W.O.G. EQUAL TO APOLLO 70LF SERIES. 1. ALL PIPING SHALL BE SEPARATELY HUNG AND SUPPORTED FROM APPROVED STRUCTURAL MEMBERS OR REMOVAL OF PIPING. OF FINISHED AREAS TO PROJECT 2" ABOVE THE FINISHED FLOOR. SLEEVES IN FLOORS OF NON -FINISHED AREAS CONCRETE OVERHEAD STRUCTURE ONLY. NO PIPE SHALL BE HUNG FROM ROOF DECK, PIPE DUCTS, OR OTHER TO PROJECT 2" ABOVE THE FINISHED FLOOR. FILL SPACE BETWEEN PIPE AND SLEEVES INTO EXPOSED AREAS WITH 3. VALVES BY MILWAUKEE, NIBCO OR WATTS MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. COMPONENTS OR EQUIPMENT OF OTHER TRADES. 3. PATCHING SHALL MATCH EXISTING SURFACES IN KIND AND FINISH, AND SHALL BE DONE BY THE GENERAL CONTRACTOR. SEALING COMPOUND. REAM ALL SLEEVES BEFORE INSTALLING. 5. ALL DOMESTIC WATER PIPING SHALL BE CLEAN, FLUSHED AND TESTED PER STATE AND LOCAL HEALTH 2. PROVIDE LISTED/APPROVED ADJUSTABLE HANGERS, INSERTS, BRACKETS, CLAMPS, SUPPLEMENTAL STEEL AND PLUMBING INSULATION DEPARTMENT REQUIREMENTS. OTHER DEVICES REQUIRED FOR PROPER SUPPORT OF ALL PIPE LINES. 4. NO STRUCTURAL MEMEBER WILL BE CUT INTO WITHOUT THE EXPRESSED PERMISSION THE OWNER'S REPRESENTATIVE. RE 1. GENERAL 6. ALL DOMESTIC WATER PIPING SHALL BE CERTIFIED SAFE FOR HUMAN CONSUMPTION BY A CERTIFIED 3. HANGERS SHALL BE DESIGNED TO ALLOW FOR EXPANSION AND CONTRACTION AND TO ALLOW INSULATION PROFESSIONAL BY THE STATE OF WEST VIRGINIA (BACTERIAL CERTIFICATION NUMBER) EMPLOYED BY A (WHERE APPLICABLE) TO RUN CONTINUOUSLY THROUGH HANGERS. G. GUARANTEE a. PROVIDE LISTED INSULATION COVER FOR ALL ITEMS/ELEMENTS AS SPECIFIED HEREIN, AS SHOWN ON TESTING LABORATORY THAT STATES THE SYSTEM MEETS THE DEPARTMENT OF HEALTH REQUIREMENTS AND IS DRAWINGS, AND FOR ANY OTHER ITEMS/ELEMENTS REQUIRING SAME. APPROVED FOR HUMAN CONSUMPTION. 4. WIRE OR STRAP HANGERS ARE NOT PERMITTED. ADJUST HANGERS SO AS TO DISTRIBUTE WEIGHT LOAD EQUALLY 1. ALL LABOR AND MATERIALS FURNISHED UNDER THIS CONTRACT SHALL BE GUARANTEED FOR A PERIOD OF ONE ON ATTACHMENTS. (1) YEAR FORM THE DATE OF FINAL ACCEPTANCE BY THE OWNER WHICH WILL COMMENCE UPON THE FINAL b. INSULATE PIPING AND ASSOCIATED ACCESSORIES AND APPURTENANCES INCLUDING IN THE FOLLOWING 7. SOLDER AND FLUX MATERIAL SHALL BE CERTIFIED "LEAD FREE" AND LISTED FOR USE WITH POTABLE WATER INSPECTION BY THE ENGINEER. DURING THIS TIME, ALL LEAKS, CORRECTION OF ALL THE FAILURES TO SUCH SYSTEMS: SYSTEMS. 5. USE OF TRAPEZE HANGERS DO NOT PERMIT THE ELIMINATION OF THE PIPING INSULATION TO NOT BE MATERIAL AND THE CORRECTION OF ALL DISCREPANCIES WITH THE PLUMBING CODE, THE CONTRACT 1. DOMESTIC COLD WATER AND HOT WATER. 3. EXECUTION CONTINUOUS THRU THE HANGER. DRAWINGS, AND THE PROJECT SPECIFICATIONS SHALL BE DONE UNDER THIS CONTRACT AT NO ADDITIONAL 6. NO PIPE SHALL BE SUPPORTED FROM ANOTHER PIPE. ALL HANGERS SHALL BE PLUMBED BEFORE INSULATION IS EXPENSE TO THE OWNER. 2. PRODUCTS a. ALL PIPING THAT SUPPLIES A FLUSH VALVE, SOLENOID VALVE (OTHER THAN SLOW -CLOSING TYPE) SPRING APPLIED AND ALL HANGERS SHALL BE DOUBLE NUTTED. ALL HANGERS SHALL MEET LOCAL CODE REQUIREMENTS. H. EXCAVATION AND BACKFILL a. ALL INSULATING MATERIALS, INCLUDING JACKETS, CEMENTS, ADHESIVES, VAPOR BARRIERS, ETC., SHALL BE RETURN OPERATOR OR OTHER QUICK CLOSING TYPE DEVICE SHALL HAVE A SHOCK ABSORBER INSTALLED IN ALL PLASTIC PIPE SHALL BE INSTALLED AND SUPPORTED PER MANUFACTURERS INSTRUCTIONS. U.L. LISTED, WITH A FLAME SPREAD RATING NOT TO EXCEED25, AND A SMOKE DEVELOPMENT RATING NOT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. UNLESS INDICATED OTHERWISE, WHERE 1. THIS CONTRACTOR SHALL EXCAVATE AND BACKFILL ALL TRENCHES AND OTHER EXCAVATIONS REQUIRED FOR TO EXCEED 50. ALL EXTERIOR FINISHES SHALL HAVE A MINIMUM SERVICE TEMPERATURE LIMIT (FSTM 70) OF MULTIPLE FIXTURES OR EQUIPMENT IN ADJACENT LOCATIONS (SUCH AS WITHIN A CHASE OR OTHER PLUMBING FIXTURES LAYING DRAINS, SEWERS, APPURTENANCES AND OTHER EXCAVATIONS REQUIRED FOR HIS WORK. MINUS 50 TO 220 DEGREES F. ENCLOSURE) ARE SUPPLIED BY COMMON PIPING MANIFOLD, A PROPERLY SIZED AND INSTALLED SHOCK ABSORBER MAY BE UTILIZED. 1. GENERAL 2. EARTH FILL: SOIL AS APPROVED BY THE OWNER'S REPRESENTATIVE, FREE OF ORGANIC SOIL, SOD, ROOTS, b. MOLDED PLASTIC FITTING COVERS SHALL BE U.L. LISTED WITH A FLAME SPREAD RATING NOT TO EXCEED 25, WOOD METAL RUBBISH DEBRIS LUMPS OR EXCESSIVE AMOUNTS OF CLAY AND ROCKS GREATER THAN 2" IN AND A SMOKE DEVELOPMENT RATING NOT TO EXCEED 50. b. RUN ALL WATER PIPING LEVEL AND CONCEAL WHENEVER POSSIBLE. PIPING TO BE INSTALLED TO ALLOW a. FURNISH AND INSTALL ALL PLUMBING FIXTURES AND ASSOCIATED ACCESSORIES AS SPECIFIED HEREIN AT DIAMETER; CAPABLE OF BEING COMPACTED INTO DENSE AND STABLE CONDITIONS AS SPECIFIED. COMPLETE DRAIN DOWN OF SYSTEM BACK TO MAIN RISER AT BASE OF SYSTEM WHENEVER POSSIBLE. LOCATIONS INDICATED ON THE DRAWINGS. FIXTURES TO BE PROVIDED FREE OF DEFECTS AND SET IN A NEAT, c. INSULATED THICKNESS IS BASED ON INSULATION HAVING THERMAL RESISTANCE IN THE RANGE OF 4.0 HR F. FINISHED AND UNIFORM MANNER. 3. ALL UNDERGROUND PIPING SHALL BE INSTALLED ON A MINIMUM OF A 3" BED OF COMPACTED SAND. ALL FT2/BTU TO 4.6 HR F. FT2/BTU PER INCH OF THICKNESS ON A FLATSURFACE AT A MEAN TEMPERATURE OF 75 c. COORDINATE INSTALLATION WITH STRUCTURE, SITE CONDITIONS AND WORK OF OTHER TRADES AT AND UNDERGROUND PIPING SHALL BE BACKFILLED BY HAND TO A LEVEL OF 6" ABOVE THE PIPE WITH CLEAN SAND. DEGREES F. MINIMUM INSULATION THICKNESS SHALL BE INCREASED FOR MATERIALS HAVING R VALUES LESS ADJACENT TO DOMESTIC WATER SERVICE PIPING INSTALLATIONS. b. WHERE FIXTURES ARE INDICATED TO BE HANDICAP ACCESSIBLE, INSTALL AS DIRECTED HEREIN AND IN ALL BACKFILL SHALL BE MADE IN LIFTS NOT TO EXCEED 12". EACH LIFT SHALL BE MECHANICALLY COMPACTED THAN 4.0 OR MAY BE REDUCED FOR MATERIALS HAVING R VALUES GREATER THAN 4.6 TO GIVE EQUIVALENT 4. FLUSHING AND STERILIZATION COMPLIANCE WITH THE CODES AND GUIDELINES REFERENCED. TO A MINIMUM OF 92% MODIFIED PROCTOR. "R" VALUES. 2. PRODUCTS 4. PROTECT ALL UTILITIES SHOWN ON DRAWINGS OR ENCOUNTERED IN THE CONSTRUCTION WORK. ANY DAMAGE "MICRO-LOK" a. FLUSH OUT ALL DOMESTIC WATER PIPING SYSTEMS TO REMOVE ALL DIRT AND GREASE FROM PIPING AND TO UTILITIES SHALL BE REPAIRED BY THIS CONTRACTOR TO OWNER'S SATISFACTION, WITHOUT COST TO THE d. PIPE COVERS SHALL BE SIMILAR TO JOHNS MANVILLE GLASS FIBER INSULATION, RATED FOR 850 EQUIPMENT BEFORE SYSTEMS ARE PLACED INTO OPERATION. CLEAN STRAINERS AFTER EACH FLUSHING UNTIL a. PLUMBING FIXTURES, TRIM, FITTINGS, ACCESSORIES, APPURTENANCES, ETC. NOT INCLUDED HEREIN ARE AS DEGREES F. WITH A FACTORY APPLIED AP-T ALL-PURPOSE SELF-SEALING VAPOR BARRIER JACKET. BUTT STRIPS THE STRAINER REMAINS CLEAN. SPECIFIED ON PLAN. OWNER. SHALL BE MINIMUM 3" WIDE, AND OF SAME MATERIAL AS JACKET. EQUAL MATERIALS, INCLUDING THICKNESS 5. THIS CONTRACTOR SHALL REMOVE ANY UNUSABLE OF SURPLUS EXCAVATED MATERIAL FROM THE SITE. AND CONDUCTIVITY RATINGS/LISTINGS. AS MANUFACTURED BY OWENS CORNING, KNAUF OR MANSON b. AFTER DOMESTIC WATER LINES ARE ALL INSTALLED, STERILIZE LINES AS PRESCRIBED BY AWWA-C-651. b. CHINA PLUMBING FIXTURES AND ACCESSORIES AS MANUFACTURED BY SLOAN. MAY BE FURNISHED, AT THE CONTRACTOR'S OPTION. WHERE INSULATION THICKNESS IS INDICATED FOR STERILIZATION SHALL BE DONE UNDER IMMEDIATE -ON-THE-JOB SUPERVISION OF A WATER TESTING c. BATTERY POWERED, SENSOR ACTIVATED FAUCETS AND ACCESSORIES AS MANUFACTURED BY SLOAN. I. RECORD DRAWINGS COVER HEREIN. IT IS NOMINAL THICKNESS REQUIRED THICKNESS. LABORATORY REGULARLY ENGAGED IN THE SERVICE AND SHALL BE DONE PER THEIR INSTRUCTIONS. ALL FEES 1. THIS CONTRACTOR SHALL KEEP AN ACCURATE RECORD OF ALL DEVIATIONS FROM CONTRACT DRAWINGS AND e. ALL CEMENTS, ADHESIVES, FINISHES, AND ASSOCIATED MATERIALS SHALL BE SIMILAR TO THAT PROVIDED BY FOR TESTING AND TEST EQUIPMENT SHALL BE PAID BY THIS CONTRACTOR. d. SEATS FOR WATER CLOSETS AS MANUFACTURED BY BEMIS, CHURCH, OR OLSONITE MAY BE FURNISHED AT SPECIFICATIONS. HE SHALL NEATLY AND CORRECTLY ENTER IN COLORED PENCIL ANY DEVIATIONS ON THE BLUE FOSTER. EQUAL MATERIALS AS PROVIDED BY CHILDERS OR VIMASCO MAY BE FURNISHED AT THE c. FURNISH A CERTIFICATE OF STERILIZATION AND APPROVAL FOR HUMAN CONSUMPTION SIGNED BY A THE CONTRACTOR'S OPTION. ALL SEATS ARE TO BE FURNISHED WITH SELF-SUSTAINING STAINLESS STEEL CHECK PRINTS OR BLUE LINE DRAWINGS. AT COMPLETION OF THE PROJECT DELIVER DRAWINGS TO OWNER'S CONTRACTOR'S OPTION. PROFESSIONAL ENGINEER REGISTERED WITHIN THE STATE AND REGULARLY IN THE EMPLOY OF THE TESTING HINGES UNLESS NOTED OTHERWISE. REPRESENTATIVE. LABORATORY. CERTIFICATION SHALL BE FURNISHED TO THE ARCHITECT/ENGINEER PRIOR TO ANY PAYMENT IS e. EQUIVALENT FIXTURE CARRIERS AS MANUFACTURED BY ZURN, JOSAM, J. R. SMITH, MIFAB, OR WATTS MAY BE PERMITS AND FEES f. LONGITUDINAL LAP JOINTS AND BUTT STRIPS FOR GLASS FIBER PIPING INSULATION SHALL BE SECURED WITH MADE. FURNISHED AT THE CONTRACTOR'S OPTION. STAPLES ON THREE (3) INCH CENTERS, AND SEALED WITH AN APPROVED VAPOR BARRIER ADHESIVE WHERE 1. THE PLUMBING CONTRACTOR SHALL APPLY FOR AND PAY ANY REVIEW INSPECTION, PERMIT, LICENSE, TESTING APPLICABLE. STAPLES ARE NOT REQUIRED WHEN INSULATION UTILIZES A "DOUBLE" ADHESIVE SELF-SEALING d. STERILIZATION: CHLORINATING MATERIAL EITHER LIQUID CHLORINE MEETING AWWA STANDARD B301, f. UNLESS INDICATED OTHERWISE, ALL EXPOSED METALLIC PARTS, PIPING, TRIM, FITTINGS, ACCESSORIES, AND/OR OTHER SERVICE FEES REQUIRED BY ALL REVIEW/INSPECTION/APPROVAL AUTHORITIES IN CONNECTION SYSTEM. SODIUM OR CALCIUM HYPOCHLORITE MEETING AWWA STANDARD B300. APPURTENANCES, ETC, ASSOCIATED WITH PLUMBING FIXTURES SHALL BE POLISHED CHROME FINISH WHEN WITH THE WORK UNDER THIS CONTRACT. 6. EXECUTION AVAILABLE. PROVIDE POLISHED CHROME PLATED BRASS ESCUTCHEONS ON PIPING AT ALL EXPOSED 3. EXECUTION STRUCTURE PENETRATIONS (WALLS, FLOORS, CEILINGS, CASEWORK, ETC,) AND AT ALL FIXTURE 2. ALL WORK SHALL ALSO BE INSTALLED IN ACCORDANCE WITH REGULATIONS OF THE FIRE UNDERWRITERS HAVING a. COVER DOMESTIC COLD WATER AND HOT WATER PIPING WITH V THICKNESS GLASS FIBER PIPE INSULATION. a. WITH ALL OUTLETS CLOSED, FILL SYSTEM TO WORKING PRESSURE AND CLOSE VALVE AT SUPPLY MAIN. CONNECTIONS. JURISDICTION AND LOCAL UTILITIES. CONTRACTOR SHALL ALSO SECURE ANY PERMITS OR PAY ANY FEES TO THE LOCAL UTILITY COMPANIES FOR THE WORK REQUIRED. b. ALL APPURTENANCES AND ACCESSORIES SUCH AS VALVES, FLANGES, UNIONS, ETC. INSTALLED IN b. A CLEANING SOLUTION CONTAINING NOT LESS THAN 150 PARTS PER MILLION OF CHLORINE SHALL BE g. AT ALL HANDICAP ACCESS LAVATORIES AND/OR SINKS WITH EXPOSED SUPPLY AND DRAIN PIPING BELOW, PRODUCTS GENERAL REFERENCED PIPING SHALL BE WRAPPED WITH FULL THICKNESS INSULATION AND COVERED WITH A LISTED INTRODUCED INTO THE SYSTEM. PROVIDE PRE -FABRICATED CLOSED CELL VINYL INSULATION/COVER ASSEMBLIES WITH SEAMLESS PVC 1. WHERE ITEMS/ELEMENTS ARE INDICATED HEREIN TO BE LISTED/APPROVED. THE INTENT OF THE SPECIFICATION IS MOLDED PLASTIC FITTING COVER, OR AN OPEN MESH GLASS CLOTH SHALL BE FIRE RESISTANT MASTIC. c. EACH OUTLET, HOT AND COLD, SHALL BE TESTED DURING FILL TO PROVE THE PRESENCE OF CHLORINE AT JACKET FOR ALL SUPPLY (FULL RANGE OF HOT, COLD AND TEMPERED) AND DRAIN PIPING. ASSEMBLY TO BE SIMILAR TO MCGUIRE PRO -WRAP SERIES, OFFSET DRAINS (IF USED) TO BE PROVIDED WITH COVER ASSEMBLIES THAT SAID ITEM/ELEMENT SHALL BE LISTED BY ALL APPLICABLE MATERIAL/CONSTRUCTION STANDARDS, AND c. USE 12" LONG SECTIONS OF CALCIUM SILICATE RIGID INSULATION, WITH JACKET SAME AS ADJACENT PIPE THAT OUTLET AND VALVES AND FAUCETS SHALL BE OPENED AND CLOSED SEVERAL TIMES DURING THE SPECIFICALLY DESIGNED FOR SAME. ASSEMBLIES TO BE LISTED BY MANUFACTURER AS HANDICAP ACCESS SUBJECT TO FINAL APPROVAL (INCLUDING METHODS OF INSTALLATION) BY ALL REVIEW/INSPECTION/APPROVAL COVERING FOR TRANSFER OF SUPPORT TO PIPING AT EACH HANGER, WITHOUT STRESS TO THE PIPE DISINFECTING TIME PERIOD. COMPLIANT. AUTHORITIES. COVERING ASSEMBLY. AT THE CONTRACTOR'S OPTION, AN APPROVED WOOD OR HIGH -DENSITY (20 LB./CU. d. WATER PIPING SYSTEMS SHALL REMAIN FILLED FOR A PERIOD OF 24 HOURS AND EACH OUTLET SHALL BE 2. UNLESS INDICATED OTHERWISE, ALL PLUMBING CONTRACT ITEMS/ELEMENTS (PIPE, FITTINGS, VALVES, FT.) FIBERGLASS BLOCK MAY BE SUBSTITUTED FOR THE RIGID INSULATION SECTION. VAPOR BARRIER TO BE AGAIN TESTED AND SHALL PRODUCE NOT LESS THAN 100 PARTS PER MILLION OF CHLORINE AT THE END OF 3. EXECUTION SPECIALTIES, FIXTURES, EQUIPMENT, ETC.) MATERIALS, CONSTRUCTION, PERFORMANCE, TESTING AND METHODS MAINTAINED THROUGHOUT. THE RETENTION PERIOD. a. PROVIDE INDIVIDUAL ACCESSIBLE STOP VALVES ON ALL FIXTURES AND EQUIPMENT SUPPLY PIPING. OF INSTALLATION TO BE AS LISTED/APPROVED BY ALL APPLICABLE MATERIAL/ CONSTRUCTION/ INSTALLATION d. ALL APPLICATIONS SHALL BE MADE ON CLEAN, DRYSURFACES WITH ALL JOINTS BUTTED FIRMLY TOGETHER. e. ALL OUTLETS SHALL BE OPENED WIDE AND THE MAIN SUPPLY VALVES OPENED. FLUSHING SYSTEM WITH b. INSTALL ALL FIXTURES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. STANDARDS FOR SAME, AND BE IN ACCORDANCE WITH THE REQUIREMENTS OF ALL REVIEW/INSPECTION/ e. INSULATION MUST RUN CONTINUOUS THROUGH HANGERS, SLEEVES AND WALL FOR ALL COLD WATER AND WATER UNTIL THE CHLORINE CONTENT IS NOT GREATER THAN 0.2 PARTS PER MILLION OR UNTIL APPROVED BY APPROVAL AUTHORITIES. THIS INCLUDES, BUT IS NOT LIMITED TO, THE STANDARDS AND AUTHORITIES REFERENCED THE HEALTH DEPARTMENT. FLUSH DRAIN VALVES. C. MOUNTING HEIGHTS OF FIXTURES AS ASSOCIATED EQUIPMENT AS INDICATED ON ARCHITECTURAL IN THIS SPECIFICATION. IN THE ABSENCE OF SUCH STANDARDS AND/OR REQUIREMENTS, THE HOT WATER PIPING. DRAWINGS. ITEM/ELEMENTMANUFACTURER'S RECOMMENDATIONS, AS CONFIRMED BY THE PLUMBING CONTRACTOR IN f. INSULATION SHALL NOT BE APPLIED UNTIL GENERAL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO f. AFTER FINAL FLUSHING ALL AERATORS ON PLUMBING BRASS SHALL BE REMOVED, CLEANED AND ADVANCE, SHALL BE FOLLOWED. MINIMIZE POTENTIAL FOR PHYSICAL OR MOISTURE DAMAGE TO THE COVER ASSEMBLY. ALL DAMAGED REINSTALLED. d. JOINTS FORMED WHERE FIXTURES COME INTO CONTACT WITH WALLS OF FLOORS SHALL BE SEALED WATERTIGHT WITH AND APPROVED SEALING COMPOUND, COORDINATE INSTALLATION AND COLOR WITH 3. UNLESS INDICATED OTHERWISE, ALL PLUMBING PIPING SHALL BE IN ACCORDANCE WITH THE FOLLOWING COVER SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. g. STERILIZATION TEST MAY BE PERFORMED AT THE SAME TIME THE PRESSURE TEST IS PLACED ON THE SYSTEM. THE CONSTRUCTION MANAGER. STANDARDS IN REGARD TO MATERIALS, CONSTRUCTION, DIMENSIONS/TOLERANCES, TYPE OF g, INSTALL PROTECTIVE SLEEVE ON ALL INSULATED, EXPOSED PIPES PENETRATING THE FLOOR STRUCTURE. RELEASED IFCR CONSTRUCTION at State and lmeal Endles 0tp at Caimal DATE: 03/07/18 Nick Mishler • Ln Ln O I- � Ol c-I � � N N � rl_ M 00 00 . .� =3 O 00 00 > cn ._ �O � vi lfl lD aA � Lna) ro Ln E +1 L 00 =5 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE+ PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z W 5 G L.ii W N \ O = 0 5� G V) Z) Co 0 2 Oo Z)O J Q zm0 J N M (Dw ~ Lu W JUG 2� QQ V) Q°Ca_ a O Lu ~o O0 M z Co W Q U J W (D~ V) w �o M< <q PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 SPECIFICATIONS PLUMBING 610: 15 M3ol 19 SPECIFICATIONS - DIVISION 23 - HVAC GENERAL MECHANICAL REQUIREMENTS: MECHANICAL CONTRACTOR SHALL SUBMIT COMPLIANCE CHECKLIST TO BUILDING OFFICIAL UPON SUBSTANTIAL COMPLETION OF PROJECT. PROVIDE EQUIPMENT INDICATED ON THE DRAWINGS, AND AS REQUIRED FOR A COMPLETE FUNCTIONING SYSTEM. DEFINITIONS: FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR INSTALLATION. INSTALL MEANS TO PLACE IN POSITION AND MAKE CONNECTIONS FOR SERVICE OR USE. PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE. COORDINATION: COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. DUCT DIMENSIONS: UNLESS OTHERWISE NOTED, DUCT DIMENSIONS ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. END OF SECTION SECTION 230700 - HVAC INSULATION PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. SURFACE -BURNING CHARACTERISTICS: 1. INDOOR INSULATION AND RELATED MATERIALS: TO BE FACTORY LABELED DESIGNATING MAXIMUM FLAME -SPREAD INDEX OF 25 OR LESS, AND SMOKE -DEVELOPED INDEX OF 50 OR LESS ACCORDING TO ASTM E 84. 2.2 INSULATION MATERIALS A. FLEXIBLE ELASTOMERIC: CLOSED -CELL, SPONGE- OR EXPANDED -RUBBER MATERIALS. COMPLY WITH ASTM C 534, TYPE I FOR TUBULAR MATERIALS AND TYPE II FOR SHEET MATERIALS. B. MINERAL -FIBER BLANKET INSULATION: COMPLY WITH ASTM C 553, TYPE II AND ASTM C 1290, TYPE I. 1. FSK JACKET: ALUMINUM -FOIL, FIBERGLASS -REINFORCED SCRIM WITH KRAFT-PAPER BACKING; COMPLYING WITH ASTM C 1136, TYPE II. 2. FSK TAPE: FOIL -FACE, VAPOR -RETARDER TAPE MATCHING FACTORY -APPLIED JACKET WITH ACRYLIC ADHESIVE; COMPLYING WITH ASTM C 1136. C. MINERAL -FIBER, PIPE AND TANK INSULATION: COMPLYING WITH ASTM C 1393, TYPE II OR TYPE IIIA CATEGORY 2, OR WITH PROPERTIES SIMILAR TO ASTM C 612, TYPE IB; AND HAVING FACTORY -APPLIED ASJ JACKET. NOMINAL DENSITY IS 2.5 LB/CU. FT. OR MORE. THERMAL CONDUCTIVITY (K-VALUE) AT 100 DEG F IS 0.29 BTU X IN./H X SQ. FT. X DEG F OR LESS. 1. ASJ: WHITE, KRAFT-PAPER, FIBERGLASS -REINFORCED SCRIM WITH ALUMINUM -FOIL BACKING; COMPLYING WITH ASTM C 1136, TYPE I. 2. ASJ TAPE: WHITE VAPOR -RETARDER TAPE MATCHING FACTORY -APPLIED JACKET WITH ACRYLIC ADHESIVE, COMPLYING WITH ASTM C 1136. D. FLEXIBLE ELASTOMERIC ADHESIVE: COMPLY WITH MIL-A-24179A,TYPE II, CLASS I. E. MINERAL -FIBER ADHESIVE: COMPLY WITH MIL-A-3316C, CLASS 2, GRADE A. F. VAPOR -BARRIER MASTIC: WATER BASED; SUITABLE FOR INDOOR AND OUTDOOR USE ON BELOW AMBIENT SERVICES; COMPLY WITH MIL-PRF-19565C, TYPE II. PART 3 - EXECUTION 3.1 INSULATION INSTALLATION A. COMPLY WITH REQUIREMENTS OF THE MIDWEST INSULATION CONTRACTORS ASSOCIATION'S "NATIONAL COMMERCIAL & INDUSTRIAL INSULATION STANDARDS" FOR INSULATION INSTALLATION ON PIPES AND EQUIPMENT. B. INSULATION INSTALLATION AT INTERIOR WALL AND PARTITION PENETRATIONS (THAT ARE NOT FIRE RATED): INSTALL INSULATION CONTINUOUSLY THROUGH WALLS AND PARTITIONS. C. INSULATION INSTALLATION AT FIRE -RATED WALL, PARTITION, AND FLOOR PENETRATIONS: INSTALL INSULATION CONTINUOUSLY THROUGH PENETRATIONS. SEAL PENETRATIONS. COMPLY WITH REQUIREMENTS IN SECTION 078400. D. FLEXIBLE ELASTOMERIC INSULATION INSTALLATION: 1. SEAL LONGITUDINAL SEAMS AND END JOINTS WITH ADHESIVE TO ELIMINATE OPENINGS IN INSULATION THAT ALLOW PASSAGE OF AIR TO SURFACE BEING INSULATED. 2. INSULATION INSTALLATION ON PIPE FITTINGS AND ELBOWS: INSTALL MITERED SECTIONS OF PIPE INSULATION. SECURE INSULATION MATERIALS AND SEAL SEAMS WITH ADHESIVE TO ELIMINATE OPENINGS IN INSULATION THAT ALLOW PASSAGE OF AIR TO SURFACE BEING INSULATED. E. MINERAL -FIBER INSULATION INSTALLATION: 1. INSULATION INSTALLATION ON STRAIGHT PIPES AND TUBES: WHERE VAPOR BARRIERS ARE INDICATED, SEAL LONGITUDINAL SEAMS, END JOINTS, AND PROTRUSIONS WITH VAPOR -BARRIER MASTIC AND JOINT SEALANT. 2. FOR INSULATION WITH FACTORY -APPLIED JACKETS ON ABOVE AMBIENT SURFACES, SECURE LAPS WITH OUTWARD CLINCHED STAPLES AT 6 INCHES O.C. 3. FOR INSULATION WITH FACTORY -APPLIED JACKETS ON BELOW AMBIENT SURFACES, DO NOT STAPLE LONGITUDINAL TABS BUT SECURE TABS WITH ADDITIONAL ADHESIVE AS RECOMMENDED BY INSULATION MATERIAL MANUFACTURER AND SEAL WITH VAPOR -BARRIER MASTIC AND FLASHING SEALANT. 4. BLANKET INSULATION INSTALLATION ON DUCTS AND PLENUMS: SECURE WITH ADHESIVE AND INSULATION PINS. 5. FOR DUCTS AND PLENUMS WITH SURFACE TEMPERATURES BELOW AMBIENT, INSTALL A CONTINUOUS UNBROKEN VAPOR BARRIER. F. PLENUMS AND DUCTS REQUIRING INSULATION: 1. CONCEALED SUPPLY AIR. 2. CONCEALED AND EXPOSED OUTDOOR AIR. 3. CONCEALED AND EXPOSED RETURN AIR LOCATED IN NONCONDITIONED SPACE. 3.2 DUCT AND PLENUM INSULATION SCHEDULE RETAIN " ONE OF" OPTION IN PARAGRAPHS IN THIS ARTICLE TO ALLOW CONTRACTOR TO SELECT PIPING MATERIALS FROM THOSE RETAINED. A. CONCEALED DUCT INSULATION SHALL BE 1-1/2" THICK MINERAL -FIBER BLANKET WITH A 1.5-LB/CU. FT. NOMINAL DENSITY. 3.3 HVAC PIPING INSULATION SCHEDULE A. CONDENSATE PIPING: INSULATION SHALL BE 1 " THICK FLEXIBLE ELASTOMERIC. B. REFRIGERANT PIPING: INSULATION SHALL BE 1 " THICK FLEXIBLE ELASTOMERIC. END OF SECTION 230700 SECTION 233100 - HVAC DUCTS AND CASINGS PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." B. STRUCTURAL PERFORMANCE: DUCT HANGERS AND SUPPORTS SHALL WITHSTAND THE EFFECTS OF GRAVITY LOADS AND STRESSES WITHIN LIMITS AND UNDER CONDITIONS DESCRIBED IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE". C. COMPLY WITH NFPA 96 FOR DUCTS CONNECTED TO COMMERCIAL KITCHEN HOODS. RELEASED IFCR CONSTRUCTION 5uuh;ezttn cnmiplanum with 311l1regwlmu ma _ m95tate and lmeal Endles 0tp at Cairemal ntro DATE: 03/07/18 Nick Mishler 2.2 DUCTS A. GALVANIZED -STEEL SHEET: ASTM A 653/A 653M, AND A 924 WITH G90 HOT -DIP GALVANIZED COATING. 1. GALVANIZED COATING DESIGNATION: G90. 2. FINISHES FOR SURFACES EXPOSED TO VIEW: MILL PHOSPHATIZED. DUCTWORK SHALL BE CLEANED OF DEBRIS AND OIL, THEN WIPED DOWN WITH VINEGAR OR OTHER SURFACE PREPARING CHEMICAL TO PREPARE DUCT FOR PAINT. B. JOINT AND SEAM TAPE, AND SEALANT: COMPLY WITH UL 181 A. PROVIDE POLYMERIC RUBBER TYPE SEALANT FOR USE ON BOTH INTERIOR LOCATED DUCTWORK AND DUCTWORK EXPOSED TO OUTDOOR CONDITIONS. SEALER SHALL HAVE HIGH BONDING STRENGTH FOR SURE, FIRST TIME SEALING OF JOINTS IN LOW, MEDIUM, AND HIGH PRESSURE DUCT SYSTEMS. SEALER SHALL BE HIGH IN SOLID CONTENT. PROVIDE A TWO PART TAPE SEALING SYSTEM, CONSISTING OF WOVEN FIBER TAPE IMPREGNATED WITH A GYPSUM MINERAL COMPOUND, AND A MODIFIED ACRYLIC/SILICONE ACTIVATOR THAT REACTS EXOTHERMICALLY WITH THE TAPE. TWO PART TAPE SEALING SYSTEM MUST BE RATED FOR BOTH INDOOR AND OUTDOOR APPLICATION. TAPE SHALL NOT CONTAIN ASBESTOS. C. METAL DUCT FABRICATION: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." 2.3 ACCESSORIES A. VOLUME DAMPERS AND CONTROL DAMPERS: SINGLE -BLADE AND MULTIPLE OPPOSED -BLADE DAMPERS, STANDARD LEAKAGE RATING, AND SUITABLE FOR HORIZONTAL OR VERTICAL APPLICATIONS; FACTORY FABRICATED AND COMPLETE WITH REQUIRED HARDWARE AND ACCESSORIES. 1. ROUND VOLUME DAMPERS: PROVIDE MINIMUM 20 GAUGE GALVANIZED STEEL FRAME AND BLADES, MINIMUM 3/8" SQUARE STEEL AXLE, MOLDED SYNTHETIC BEARINGS, WITH LOCKING POSITION REGULATOR. REGULATOR SHALL BE POSITIONED WITH SHEET METAL BRACKET BEYOND DUCT COVERING. WHERE POSITIONING REGULATOR IS NOT ACCESSIBLE, PROVIDE COUPLING AND EXTENSION ROD WITH REGULATOR FOR CEILING OR WALL INSTALLATION, AS REQUIRED. 2. RECTANGULAR VOLUME DAMPERS: PROVIDE MINIMUM 16 GAUGE GALVANIZED STEEL CHANNEL FRAME, 16 GAUGE GALVANIZED STEEL BLADES, MINIMUM '/2" HEXAGONAL AXLE, BOLDED SYNTHETIC BEARINGS, WITH 3/8" SQUARE PLATED STEEL CONTROL SHAFT. LINKAGES SHALL BE CONCEALED IN THE FRAME. OPERATING SHAFT SHALL EXTEND BEYOND FRAME AND DUCT TO A LOCKING QUADRANT WITH ADJUSTABLE LEVER. MAXIMUM BLADE WIDTH SHALL NOT EXCEED 6". B. FLEXIBLE DUCT CONNECTORS: FLAME -RETARDED OR NONCOMBUSTIBLE FABRICS, COATINGS, AND ADHESIVES COMPLYING WITH UL 181, CLASS 1. CONNECTOR TO BE 30 OUNCE, NEOPRENE COATED, FIBERGLASS FABRIC. C. FLEXIBLE DUCTS: FACTORY ASSEMBLED, UL 181, CLASS 1, WITH 1-1/2-INCH THICK (R-5 MIN.), 1 PCF FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPOR BARRIER. FLEXIBLE DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50, AND SHALL BE RATED FOR MINIMUM 2-INCH WG PRESSURE AND 0 TO 250OF TEMPERATURE. PROVIDE SCREW -OPERATED METAL ADJUSTABLE CLAMPING DEVICES. USE TWIST -LOCK CONICAL TAP COLLARS AT CONNECTIONS INTO SHEET METAL DUCTWORK. MAXIMUM EXTENDED LENGTH OF FLEXIBLE DUCT SHALL NOT EXCEED 5 FEET. D. TURNING VANES: PROVIDE FABRICATED TURNING VANES AND VANE RUNNERS, CONSTRUCTED IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS". PROVIDE TURNING VANES CONSTRUCTED OF CURVED BLADES, SUPPORTED WITH BARS PERPENDICULAR TO BLADES, AND SET INTO SIDE STRIPS SUITABLE FOR MOUNTING IN DUCTWORK. FOLLOW SMACNA GUIDELINES FOR SPACING SUPPORT, AND CONSTRUCTION. ALL BLADES SHALL BE DOUBLE THICKNESS AIRFOIL TYPE. E. BIRD SCREENS AND FRAMES: PROVIDE BIRD SCREENS THAT CONFORM TO ASTM E 2016, NO. 2 MESH, ALUMINUM OR STAINLESS STEEL. PROVIDE "MEDIUM -LIGHT" RATED ALUMINUM SCREENS. PROVIDE "LIGHT" RATES STAINLESS STEEL SCREENS. F. DUCT -MOUNTED ACCESS DOORS: FABRICATE ACCESS PANELS ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE"; FIGURES 2-10, "DUCT ACCESS DOORS AND PANELS," AND 2-11, "ACCESS PANELS - ROUND DUCT." PART 3 - EXECUTION 3.1 INSTALLATION A. INSTALL DUCTWORK, ACCESSORIES, AND SUPPORTS ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" UNLESS OTHERWISE INDICATED. B. SEAL DUCTS TO THE FOLLOWING SEAL CLASSES ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE": 1-INCH WG, SEAL CLASS A. C. CONCEAL DUCTS FROM VIEW IN FINISHED AND OCCUPIED SPACES. D. AVOID PASSING THROUGH OR ABOVE ELECTRICAL EQUIPMENT SPACES AND ENCLOSURES. E. CLEAN DUCT SYSTEMS BEFORE TESTING, ADJUSTING, AND BALANCING. 3.2 TESTING, ADJUSTING, AND BALANCING A. BALANCE AIRFLOW WITHIN DISTRIBUTION SYSTEMS, INCLUDING SUBMAINS, BRANCHES, AND TERMINALS TO INDICATED QUANTITIES PER SPECIFICATIONS. END OF SECTION 233100 SECTION 233713 - DIFFUSERS, REGISTERS, AND GRILLES PART1- GENERAL 1.1 SECTION REQUIREMENTS A. SUBMITTALS: 1. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED, INCLUDING COLOR CHARTS FOR FACTORY FINISHES. PART 2 - PRODUCTS 2.1 DIFFUSERS, REGISTERS, AND GRILLES: A. REFER TO SCHEDULES FOR FINISH TYPE, COLOR, MATERIAL, AND MOUNTING. PART 3 - EXECUTION 3.1 INSTALLATION A. INSTALL DIFFUSERS, REGISTERS, AND GRILLES LEVEL AND PLUMB. B. CEILING -MOUNTED OUTLETS AND INLETS: DRAWINGS INDICATE GENERAL ARRANGEMENT OF DUCTS, FITTINGS, AND ACCESSORIES. MAKE FINAL LOCATIONS WHERE INDICATED, AS MUCH AS PRACTICAL. FOR UNITS INSTALLED IN LAY -IN CEILING PANELS, LOCATE UNITS IN THE CENTER OF PANEL UNLESS OTHERWISE INDICATED. WHERE ARCHITECTURAL FEATURES OR OTHER ITEMS CONFLICT WITH INSTALLATION, NOTIFY ARCHITECT FOR A DETERMINATION OF FINAL LOCATION. C. AFTER INSTALLATION, ADJUST DIFFUSERS, REGISTERS, AND GRILLES TO AIR PATTERNS INDICATED, OR AS DIRECTED, BEFORE STARTING AIR BALANCING. END OF SECTION 233713 SECTION 237413 - PACKAGED ROOFTOP UNITS 1.1 SUMMARY A. THIS SECTION INCLUDES PACKAGED, ROOFTOP UNITS WITH THE FOLLOWING COMPONENTS AND ACCESSORIES: 1. DIRECT -EXPANSION COOLING. 2. ELECTRIC RESISTANCE HEATING. 3. ECONOMIZER OUTDOOR -AND RETURN -AIR DAMPER SECTION. 4. INTEGRAL, SPACE TEMPERATURE CONTROLS. 5. ROOF CURBS. 1.2 SECTION REQUIREMENTS A. SUBMITTALS: 1. PRODUCT DATA: INCLUDE MANUFACTURER'S TECHNICAL DATA FOR EACH RTU, INCLUDING RATED CAPACITIES, DIMENSIONS, REQUIRED CLEARANCES, CHARACTERISTICS, FURNISHED SPECIALTIES, AND ACCESSORIES. PART 2 - PRODUCTS 2.1 CASING A. GENERAL FABRICATION REQUIREMENTS FOR CASINGS: FORMED AND REINFORCED INSULATED PANELS, FABRICATED TO ALLOW REMOVAL FOR ACCESS TO INTERNAL PARTS AND COMPONENTS, WITH JOINTS BETWEEN SECTIONS SEALED. B. EXTERIOR CASING MATERIAL: GALVANIZED STEEL WITH FACTORY -PAINTED FINISH, WITH PITCHED ROOF PANELS AND KNOCKOUTS WITH GROMMET SEALS FOR ELECTRICAL AND PIPING CONNECTIONS AND LIFTING LUGS. 1. CASING THICKNESS: 16 G/'HUGE::: FlilCl(. C. CASING INSULATION AND ADHESIVE: COMPLY WITH NFPA 90A. 1. MATERIALS: ASTM C 1071,TYPE I. 2. THICKNESS: 1/2 INCH 3. LINER MATERIALS SHALL HAVE AIR -STREAM SURFACE INSULATED WITH A MINIMUM 1/2-IN. THICK, MINIMUM 1 1/2 LB DENSITY, FLEXIBLE FIBERGLASS INSULATION BONDED WITH A PHENOLIC BINDER, NEOPRENE COATED ON THE AIR SIDE. 4. LINER ADHESIVE: COMPLY WITH ASTM C 916, TYPE I. D. UNIT SHALL HAVE A THRU-THE-BASE GAS AND ELECTRICAL CONNECTIONS. 2.2 FANS OPTION A OR B: A. DIRECT -DRIVEN SUPPLY -AIR FANS: DOUBLE WIDTH, BACKWARD INCLINED, CENTRIFUGAL; WITH PERMANENTLY LUBRICATED, MOTOR RESILIENTLY MOUNTED IN THE FAN INLET. ALUMINUM OR PAINTED -STEEL WHEELS, AND GALVANIZED- OR PAINTED -STEEL FAN SCROLLS. B. BELT -DRIVEN SUPPLY -AIR FANS: DOUBLE WIDTH, FORWARD CURVED, CENTRIFUGAL; WITH PERMANENTLY LUBRICATED, SINGLE -SPEED MOTOR INSTALLED ON AN ADJUSTABLE FAN BASE RESILIENTLY MOUNTED IN THE CASING. ALUMINUM OR PAINTED -STEEL WHEELS, AND GALVANIZED- OR PAINTED -STEEL FAN SCROLLS. C. CONDENSER -COIL FAN: DIRECT DRIVE, PROPELLER, MOUNTED ON SHAFT OF PERMANENTLY LUBRICATED MOTOR WITH THERMAL OVERLOAD PROTECTION. D. POWER EXHAUST: FORWARD CURVED, SHAFT MOUNTED ON PERMANENTLY LUBRICATED MOTOR. 2.3 COILS A. SUPPLY -AIR REFRIGERANT COIL: 1. ALUMINUM -PLATE FIN AND SEAMLESS INTERNALLY GROOVED COPPER TUBE IN STEEL CASING WITH EQUALIZING -TYPE VERTICAL DISTRIBUTOR. 2. POLYMER STRIP SHALL PREVENT ALL COPPER COIL FROM CONTACTING STEEL COIL FRAME OR CONDENSATE PAN. 3. CATHODIC EPDXY COATING. 4. CONDENSATE DRAIN PAN: GALVANIZED STEEL WITH CORROSION -RESISTANT COATING FORMED WITH PITCH AND DRAIN CONNECTIONS. B. OUTDOOR -AIR REFRIGERANT COIL: 1. ALUMINUM -PLATE FIN AND SEAMLESS INTERNALLY GROOVED COPPER TUBE IN STEEL CASING WITH EQUALIZING -TYPE VERTICAL DISTRIBUTOR. 2. POLYMER STRIP SHALL PREVENT ALL COPPER COIL FROM CONTACTING STEEL COIL FRAME OR CONDENSATE PAN. 3. CATHODIC EPDXY COATING. C. HOT -GAS REHEAT REFRIGERANT COIL (OPTIONAL): 1. ALUMINUM -PLATE FIN AND SEAMLESS INTERNALLY GROOVED COPPER TUBE IN STEEL CASING WITH EQUALIZING -TYPE VERTICAL DISTRIBUTOR. 2. POLYMER STRIP SHALL PREVENT ALL COPPER COIL FROM CONTACTING STEEL COIL FRAME OR CONDENSATE PAN. 3. CATHODIC EPDXY COATING. 2.4 REFRIGERANT CIRCUIT COMPONENTS A. NUMBER OF REFRIGERANT CIRCUITS: TWO B. COMPRESSOR: HERMETIC, SCROLL, MOUNTED ON VIBRATION ISOLATORS; WITH INTERNAL OVERCURRENT AND HIGH -TEMPERATURE PROTECTION, INTERNAL PRESSURE RELIEF AND CRANKCASE HEATER. C. REFRIGERATION SPECIALTIES: 1. REFRIGERANT: R-410A 2. EXPANSION VALVE WITH REPLACEABLE THERMOSTATIC ELEMENT. 3. REFRIGERANT FILTER/DRYER. 4. MANUAL -RESET HIGH-PRESSURE SAFETY SWITCH. 5. AUTOMATIC -RESET LOW-PRESSURE SAFETY SWITCH. 6. MINIMUM OFF -TIME RELAY. 7. AUTOMATIC -RESET COMPRESSOR MOTOR THERMAL OVERLOAD. 8. BRASS SERVICE VALVES INSTALLED IN COMPRESSOR SUCTION AND LIQUID LINES. 9. LOW -AMBIENT KIT HIGH-PRESSURE SENSOR. 10. HOT -GAS REHEAT SOLENOID VALVE WITH A REPLACEABLE MAGNETIC COIL. 2.5 AIR FILTRATION A. PROVIDE 2" THROW -AWAY FIBERGLASS FILTERS. 2.7 DAMPERS A. OUTDOOR AND RETURN AIR MIXING DAMPERS: PARALLEL OR OPPOSED -BLADE GALVANIZED -STEEL DAMPERS MECHANICALLY FASTENED TO CADMIUM PLATED FOR GALVANIZED -STEEL OPERATING ROD IN REINFORCED CABINET. CONNECT OPERATING RODS WITH COMMON LINKAGE AND INTERCONNECT LINKAGES SO DAMPERS OPERATE SIMULTANEOUSLY. 1. DAMPER MOTOR: MODULATING WITH ADJUSTABLE MINIMUM POSITION. 2. RELIEF AIR DAMPER: GRAVITY ACTUATED, WITH BIRD SCREEN AND HOOD. 2.8 ELECTRICAL POWER CONNECTION A. PROVIDE FOR SINGLE CONNECTION OF POWER TO UNIT WITH UNIT -MOUNTED DISCONNECT SWITCH ACCESSIBLE FROM OUTSIDE UNIT AND CONTROL -CIRCUIT TRANSFORMER WITH BUILT-IN OVERCURRENT PROTECTION. 2.9 CONTROLS A. BASIC UNIT CONTROLS: 1. CONTROL -VOLTAGE TRANSFORMER. 2. WALL -MOUNTED THERMOSTAT OR SENSOR WITH THE FOLLOWING FEATURES: a.HEAT-COOL-OFF SWITCH. b. FAN ON -AUTO SWITCH. c. FAN -SPEED SWITCH. d. AUTOMATIC CHANGEOVER. e. ADJUSTABLE DEADBAND. f. EXPOSED SET POINT. g.EXPOSED INDICATION. h. DEGREE F INDICATION. i. UNOCCUPIED -PERIOD -OVERRIDE PUSH BUTTON. j. DATA ENTRY AND ACCESS PORT TO INPUT TEMPERATURE AND HUMIDITY SET POINTS, OCCUPIED AND UNOCCUPIED PERIODS, AND OUTPUT ROOM TEMPERATURE AND HUMIDITY, SUPPLY -AIR TEMPERATURE, OPERATING MODE, AND STATUS. 3. WALL -MOUNTED HUMIDISTAT OR SENSOR WITH THE FOLLOWING FEATURES: a.EXPOSED SET POINT. b. EXPOSED INDICATION. 4. REMOTE WALL -MOUNTED ANNUNCIATOR PANEL WITH KEYED ACCESS FOR EACH UNIT: a.LIGHTS TO INDICATE POWER ON, UNIT ALARM OR FAILURE, SMOKE DETECTION. B. DDC CONTROLLER: 2. SAFETY CONTROL OPERATION: a. SMOKE DETECTORS: STOP FAN AND CLOSE OUTDOOR -AIR DAMPER IF SMOKE IS DETECTED. PROVIDE ADDITIONAL CONTACTS FOR ALARM INTERFACE TO FIRE ALARM CONTROL PANEL. b. FIRE ALARM CONTROL PANEL INTERFACE WHERE APPLICABLE. c. LOW -DISCHARGE TEMPERATURE: STOP FAN AND CLOSE OUTDOOR -AIR DAMPER IF SUPPLY AIR TEMPERATURE IS LESS THAN 40°F. RETAIN FIRST SUBPARAGRAPH BELOW FOR AIR-TO-AIR HEAT -PUMP FEATURE. d.DEFROST CONTROL FOR CONDENSER COIL: PRESSURE DIFFERENTIAL SWITCH TO INITIATE DEFROST SEQUENCE. 3. UNIT SHALL BE CAPABLE OF DIRECT COMMUNICATION WITH GENERIC OPEN PROTOCOL SUCH AS BACNET MS/TP, LONTALK, OR MODUS. THIS WILL ALLOW THE UNIT TO INTEGRATE WITH A FACILITY ENERGY MANAGEMENT SYSTEM. 4. SCHEDULED OPERATION: OCCUPIED AND UNOCCUPIED PERIODS ON SEVEN-DAY CLOCK WITH A MINIMUM OF FOUR PROGRAMMABLE PERIODS PER DAY. 5. UNOCCUPIED PERIOD: a. HEATING SETBACK: 10°F. b. COOLING SETBACK: SYSTEM OFF. c. OVERRIDE OPERATION: TWO HOURS. 6. SUPPLY FAN OPERATION: a. OCCUPIED PERIODS: RUN FAN CONTINUOUSLY. b. UNOCCUPIED PERIODS: CYCLE FAN TO MAINTAIN SETBACK TEMPERATURE. 7. REFRIGERANT CIRCUIT OPERATION: a. OCCUPIED PERIODS: CYCLE OR STAGE COMPRESSORS, AND OPERATE HOT -GAS BYPASS TO MATCH COMPRESSOR OUTPUT TO COOLING LOAD TO MAINTAIN ROOM TEMPERATURE AND HUMIDITY. CYCLE CONDENSER FANS TO MAINTAIN MAXIMUM HOT -GAS PRESSURE. OPERATE LOW -AMBIENT CONTROL KIT TO MAINTAIN MINIMUM HOT -GAS PRESSURE. b. UNOCCUPIED PERIODS: CYCLE COMPRESSORS AND CONDENSER FANS FOR HEATING TO MAINTAIN SETBACK TEMPERATURE. 8. HOT -GAS REHEAT -COIL OPERATION (OPTIONAL): a. OCCUPIED PERIODS: HUMIDISTAT OPENS HOT -GAS VALVE TO PROVIDE HOT -GAS REHEAT, AND CYCLES COMPRESSOR. b. UNOCCUPIED PERIODS: REHEAT NOT REQUIRED. 9. GAS FURNACE OPERATION: a. OCCUPIED PERIODS: STAGE BURNER TO MAINTAIN ROOM TEMPERATURE. b. UNOCCUPIED PERIODS: CYCLE BURNER TO MAINTAIN SETBACK TEMPERATURE. 10. FIXED MINIMUM OUTDOOR -AIR DAMPER OPERATION: a. OCCUPIED PERIODS: OPEN TO 25 PERCENT. b. UNOCCUPIED PERIODS: CLOSE THE OUTDOOR -AIR DAMPER. 11. ECONOMIZER OUTDOOR -AIR DAMPER OPERATION: a. OCCUPIED PERIODS: OPEN TO 25 PERCENT FIXED MINIMUM INTAKE, AND MAXIMUM 100 PERCENT OF THE FAN CAPACITY TO COMPLY WITH ASHRAE CYCLE II. CONTROLLER SHALL PERMIT AIR -SIDE ECONOMIZER OPERATION WHEN OUTDOOR AIR IS LESS THAN 60 ° F. USE MIXED -AIR TEMPERATURE AND SELECT BETWEEN OUTDOOR -AIR AND RETURN -AIR ENTHALPY TO ADJUST MIXING DAMPERS DURING ECONOMIZER CYCLE OPERATION, LOCK OUT COOLING. b. UNOCCUPIED PERIODS: CLOSE OUTDOOR -AIR DAMPER AND OPEN RETURN -AIR DAMPER. 2.10 ACCESSORIES A. DUPLEX, 115-V, GROUND -FAULT -INTERRUPTER OUTLET WITH 15-A OVERCURRENT PROTECTION. INCLUDE TRANSFORMER IF REQUIRED. B. LOW -AMBIENT KIT STAGED DOWN TO 0°F. C. FILTER DIFFERENTIAL PRESSURE SWITCH WITH SENSOR TUBING ON EITHER SIDE OF FILTER. SET FOR FINAL FILTER PRESSURE LOSS. D. HAIL GUARDS OF GALVANIZED STEEL, PAINTED TO MATCH CASING. E. DUCT MOUNTED SMOKE DETECTOR IN RETURN AIR STREAM CAPABLE OF SHUTTING DOWN THE UNIT IN THE PRESENCE OF SMOKE DETECTION. 2.11 ROOF CURBS A. MATERIALS: GALVANIZED STEEL WITH CORROSION -PROTECTION COATING, WATERTIGHT GASKETS, AND FACTORY -INSTALLED WOOD NAILER; COMPLYING WITH N RCA STANDARDS. 1. CURB INSULATION AND ADHESIVE: COMPLY WITH NFPA 90A OR NFPA 90B. a. MATERIALS: ASTM C 1071,TYPE I OR II. b. THICKNESS: 1-1/2 INCHES. 2. APPLICATION: FACTORY APPLIED WITH ADHESIVE AND MECHANICAL FASTENERS TO THE INTERNAL SURFACE OF CURB. a. LINER ADHESIVE: COMPLY WITH ASTM C 916, TYPE I. b. MECHANICAL FASTENERS: GALVANIZED STEEL, SUITABLE FOR ADHESIVE ATTACHMENT, MECHANICAL ATTACHMENT, OR WELDING ATTACHMENT TO DUCT WITHOUT DAMAGING LINER WHEN APPLIED AS RECOMMENDED BY MANUFACTURER AND WITHOUT CAUSING LEAKAGE IN CABINET. c. LINER MATERIALSSHALL HAVE AIR -STREAM SURFACE INSULATED WITH A MINIMUM 1/2-IN. THICK, MINIMUM 1 1/2 LB DENSITY, FLEXIBLE FIBERGLASS INSULATION BONDED WITH A PHENOLIC BINDER, NEOPRENE COATED ON THE AIR SIDE. d. LINER ADHESIVE: COMPLY WITH ASTM C 916, TYPE I. B. CURB HEIGHT: 14 INCHES TYPICAL. PROVIDE 24 INCH CURB IN AREAS WITH EXPECTED HEAVY SNOWFALL. • Ln Ln O I- > Ol c-I � � N N � rl_ M 00 00 . .� =3 O 00 00 > cn .- �O L vi lfl lD t]A � Ln a) Cu Ln E +1 L 00 =5 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE+ PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z W 75;G L.ii W N \ O = 0 5� G Z) Co 0 2 Oo Z)o J Q zm0 J N M (Dw W JUG 2� ' QQ �z �o V) O'�'a C) zo M�z �m W Q U J W (D~ cn U < � � � w M Sao < <q 00 rl U L rl PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 SPECIFICATIONS MECHANICAL SHEET: M3o2 SPECIFICATIONS -DIVISION 23 - HVAC (CONTINUED) PART 3 - EXECUTION 3.1 EXAMINATION A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF RTUS. B. EXAMINE ROUGHING -IN FOR RTUS TO VERIFY ACTUAL LOCATIONS OF PIPING AND DUCT CONNECTIONS BEFORE EQUIPMENT INSTALLATION. C. EXAMINE ROOFS FOR SUITABLE CONDITIONS WHERE RTUS WILL BE INSTALLED. D. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.2 INSTALLATION A. ROOF CURB: INSTALL ON ROOF STRUCTURE, LEVEL AND SECURE. INSTALL RTUS ON CURBS AND COORDINATE ROOF PENETRATIONS AND FLASHING WITH ROOF CONSTRUCTION. RTUS TO UPPER CURB RAIL, AND SECURE CURB BASE TO ROOF FRAMING OR CONCRETE BASE WITH ANCHOR BOLTS. 3.3 CONNECTIONS A. . THE FOLLOWING ARE SPECIFIC CONNECTION REQUIREMENTS: 1. INSTALL DUCTS TO TERMINATION AT TOP OF ROOF CURB. 2. REMOVE ROOF DECKING ONLY AS REQUIRED FOR PASSAGE OF DUCTS. DO NOT CUT OUT DECKING UNDER ENTIRE ROOF CURB. 3.4 COORDINATION A. CONTRACTOR TO COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER TO ENSURE THAT THE RTUS ARE COORDINATED WITH THE KITCHEN EQUIPMENT, PARTICULARLY THE EXHAUST HOODS AND THE MAKE-UP AIR UNIT, TO PROPERLY PRESSURIZE THE BUILDING/SPACE. B. CONTRACTOR TO ENSURE THAT ALL THERMOSTATS AND SENSORS ARE COMPATIBLE WITH THE RTU CONTROLS. 3.5 FIELD QUALITY CONTROL A. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT, TEST, AND ADJUST COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS. REPORT RESULTS IN WRITING. B. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. 1. MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS, INCLUDING CONNECTIONS, AND TO ASSIST IN TESTING. REPORT RESULTS IN WRITING. C. TESTSAND INSPECTIONS: 1. AFTER INSTALLING RTUS AND AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, TEST UNITS FOR COMPLIANCE WITH REQUIREMENTS. 2. OPERATIONAL TEST: AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, START UNITS TO CONFIRM PROPER MOTOR ROTATION AND UNIT OPERATION. 3. TEST AND ADJUST CONTROLS AND SAFETIES. REPLACE DAMAGED AND MALFUNCTIONING CONTROLS AND EQUIPMENT. D. REMOVE AND REPLACE MALFUNCTIONING UNITS AND RETEST AS SPECIFIED ABOVE. 3.6 STARTUP SERVICE A. ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO PERFORM STARTUP SERVICE. B. COMPLETE INSTALLATION AND STARTUP CHECKS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS AND DO THE FOLLOWING: 1. INSPECT FOR VISIBLE DAMAGE TO UNIT CASING, FURNACE COMBUSTION CHAMBER, COMPRESSOR, COILS, AND FANS. 2. VERIFY THAT LABELS ARE CLEARLY VISIBLE, CLEARANCES HAVE BEEN PROVIDED FOR SERVICING, CONTROLS ARE CONNECTED AND OPERABLE, AND FILTERS ARE INSTALLED. 3. CLEAN CONDENSER COIL AND FURNACE AND INSPECT FOR CONSTRUCTION DEBRIS. 4. REMOVE PACKING FROM VIBRATION ISOLATORS. 5. VERIFY LUBRICATION ON FAN AND MOTOR BEARINGS. 6. INSPECT FAN -WHEEL ROTATION FOR MOVEMENT INCORRECT DIRECTION WITHOUT VIBRATION AND BINDING. 7. ADJUST FAN BELTS TO PROPER ALIGNMENT AND TENSION. 8. START UNIT ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. a. INSPECT AND RECORD PERFORMANCE OF INTERLOCKS AND PROTECTIVE DEVICES; VERIFY SEQUENCES. 10. OPERATE UNIT FOR AN INITIAL PERIOD AS RECOMMENDED OR REQUIRED BY MANUFACTURER. 11. PERFORM THE FOLLOWING OPERATIONS FOR BOTH MINIMUM AND MAXIMUM FIRING. ADJUST BURNER FOR PEAK EFFICIENCY. a. MEASURE GAS PRESSURE ON MANIFOLD. b. INSPECT OPERATION OF POWER VENTS. c. MEASURE SUPPLY -AIR TEMPERATURE AND VOLUME WHEN BURNER IS AT MAXIMUM FIRING RATE AND WHEN BURNER IS OFF. CALCULATE USEFUL HEAT TO SUPPLY AIR. 20. ADJUST AND INSPECT HIGH -TEMPERATURE LIMITS. 21. INSPECT OUTDOOR -AIR DAMPERS FOR PROPER STROKE AND INTERLOCK WITH RETURN -AIR DAMPERS. 22. INSPECT CONTROLS FOR CORRECT SEQUENCING OF HEATING, MIXING DAMPERS, REFRIGERATION, AND NORMAL AND EMERGENCY SHUTDOWN. 23. SIMULATE MAXIMUM COOLING DEMAND AND INSPECT THE FOLLOWING: a. COMPRESSOR REFRIGERANT SUCTION AND HOT -GAS PRESSURES. b. SHORT CIRCUITING OF AIR THROUGH CONDENSER COIL OR FROM CONDENSER FANS TO OUTDOOR -AIR INTAKE. 27. VERIFY OPERATION OF REMOTE PANEL INCLUDING PILOT -LIGHT OPERATION AND FAILURE MODES. INSPECT THE FOLLOWING: a. HIGH -TEMPERATURE LIMIT ON HEAT EXCHANGER. b. LOW -TEMPERATURE SAFETY OPERATION. c. FILTER HIGH-PRESSURE DIFFERENTIAL ALARM. d.ECONOMIZER TO MINIMUM OUTDOOR -AIR CHANGEOVER. e. RELIEF -AIR FAN OPERATION. f. SMOKE ALARMS. 28. AFTER STARTUP AND PERFORMANCE TESTING AND PRIOR TO SUBSTANTIAL COMPLETION, REPLACE EXISTING FILTERS WITH NEW FILTERS. 3.7 CLEANING AND ADJUSTING A. OCCUPANCY ADJUSTMENTS: WHEN REQUESTED WITHIN 12 MONTHS OF DATE OF SUBSTANTIAL COMPLETION, PROVIDE ON -SITE ASSISTANCE IN ADJUSTING SYSTEM TO SUIT ACTUAL OCCUPIED CONDITIONS. PROVIDE UP TO TWO VISITS TO SITE DURING OTHER -THAN -NORMAL OCCUPANCY HOURS FOR THIS PURPOSE. B. AFTER COMPLETING SYSTEM INSTALLATION AND TESTING, ADJUSTING, AND BALANCING RTU AND AIR -DISTRIBUTION SYSTEMS, CLEAN FILTER HOUSINGS AND INSTALL NEW FILTERS. 19 a v 0 � 0) M 00 00 n rl_ > N •— C: TH T__l 10 ta vi l0 l0 qp =5 Ln Ln 00 :3 0 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE+ PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z 5W G L.ii W N \ O = 0 5� G Z) 0 Sm Oo Z)0 J Q zm0 J N M �w W J U ' QQ �z �o V) Q 0 LU �_ Q z 00 M � Q z � Co W J z UocWc Q al G =a cn W � �< <o rl U L rl PROJECT NUMBER: WPGO07 ISSUE DATE PERMIT FEB. 01, 2018 SPECIFICATIONS MECHANICAL 610: 15 M33 RELEASED IFCR CONSTRUCTION 5uuh;ezttn cnmiplanum with 311l1regwlmu ma _ m95tate and lmeal Endles 0tp at Cairemal ntro DATE: 03/07/18 Nick Mishler a N O V1 r- o r RELEASED IFCR CONSTRUCTION 5uud9ezttn cnmplanum with 311l1ru9ulmtima _ n9 State and lmeal Endes ntro DATE: 03/07/18 Nick Mishler LUMINAIRE SCHEDULE TYPE DESCRIPTION MANUFACTURER MODEL HOUSING / MOUNTING LAMP TYPE BALLAST / DRIVER COMMENTS VOLTS INPUT WATTS R1 COMBO LIGHT/FAN NUTONE 769RL RECESSED INCANDESCENT ELECTRONIC - 120 100 R2 LED TROFFER CREE ZR22-32L-40K-1 OV RECESSED LED ENGINE LED DRIVER - 120 40 EX1 COMBINATION EMERGENCY EXIT SIGN LITHONIA LHQM-SW 3R-HO UNIVERSAL WITH UNIT N/A WITH EMERGENCY BATTERY PACK 120 3.3 EM1 EMERGENCY BATTERY PACK WITH DUAL HEADS NAVILITE N1 W H W ALL WITH UNIT N/A WITH EMERGENCY BATTERY PACK 120 10.8 NOTES: 1.) ELECTRICAL CONTRACTOR SHALL PROVIDE LIGHTING FIXTURES ABOVE. ANY LIGHTING EQUALS SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW AND APPROVAL. PANEL NAME A (EXISTING) I VOLTAGE 1 208 1 PHASE 3 1 WIRE 4 LOCATION: REAR SOURCE: (E) TENANT DISCONNECI I 1200AMCB # K L R M X H C BREAKER DESCRIPTION KVA/PHASE DESCRIPTION BREAKER K L R M X H C# AMP POLE A B C AMP POLE 1 30 2 SPARE 6.1 1hlllllllllllll RTU -1 (HACR RATED BREAKER) 60 3 6.1 2 3 6.1 6.1 4 5 0.2 20 1 RESTROOM LIGHTING ................................ 6.3 6.1 6 7 0.3 2 0 1 TENANT SPACE - LIGHTING 0.3 .,.,., S PARE 2 0 1 8 9 0.4 2 0 1 SHOW WINDOW RECEPTACLES .4 0. S PARE 2 0 1 1 0 11 1.1 15 3 EWH-1 - ELECTRIC WATER HEATER 1.1 SPARE 20 1 12 13 1.1 1...1 SPARE 40 2 14 15 1.1 1.,.,1 16 17 1 0.2 1 1 L20 1 NIGHT LIGHTING EMERG FIXTURES / O .2 S PARE 2 0 1 1 8 19 0.4 20 1 RECEPTACLES 0.4 SPARE 20 1 20 21 20 1 SPARE 0.0)) SPARE 20 1 22 23 20 1 SPARE ................................ 0.0 SPARE 20 1 24 25 20 1 SPARE 0.0 SPARE 20 1 26 27 20 1 SPARE 0.0 ))))))))))))))) SPARE 20 1 28 29 20 1 SPARE 0.0 SPARE 20 1 30 3 1 0.8 2 0 1 EX. AD RE PT. BELOW PNL'A' QUAD C O 0.8 S PARE 2 0 1 3 2 33 20 1 SPARE 0.0 ))))))))))))))) SPARE 20 1 34 35 20 1 SPARE 0.0 SPARE 20 1 36 37 20 1 SPARE 0.0 SPARE 20 1 38 391 1 1 1 1 1 1 1 20 1 1 ISPARE 0.0 ii iiiiii SPARE 20 1 I40 411 1 1 1 1 1 1 1 20 1 1 ISPARE 0.0 SPARE 1 20 1 1 1 1 42 TOTAL CONNECTED LOAD/PH 8.7 7.6 7.6 BREAKER NOTES H = PROVIDE HID RATED BREAKER. L = PROVIDE A BREAKER LOCK ON DEVICE T = PROVIDE ASHUNT TRIP BREAKER. G = PROVIDE A GFI BREAKER. A= PROVIDE AN ARC FAULT CIRCUIT INTERRUPTER BREAKER. 0.01 0.71 1.61 0.01 3.31 0.01 18.31 TOTAL CONNECTED LOAD 23.90 K = KITCHEN DEMAND 65% 0.0 KVA L = LITE DEMAND 125% 0.9 KVA R = RCPT FIRST IOKVAAT 100% AND REMAINING AT 50% 1.6 KVA M = MOTOR DEMAND 100% 0.0 KVA X = MISC DEMAND 100% 3.3 KVA COMMENTS 1. PROVIDE (2)#12,(1)#12GND,3/4"C FOR ALL BRANCH CCTS UNLESS STATED OTHERWISE. 2. PROVIDE HACR RATED BREAKERS ON ALL MOTOR LOADS. 3. PROVIDE LOCKING TYPE BREAKER FOR ALL LIFE SAFETY AND NIGHT LIGHTING BRANCH CIRCUITS. H = HEAT I IDEMAND 100% IF H>C, 0% IF H<C 0.0 KVA C = COOL I IDEMAND 100% IF C>H, 0% IF C<H 18.3 KVA TOTAL PANEL DEMAND = TOTAL PANEL AMPS = 24.1 KVA 669 AMPS ELECTRICAL - LIGHTING 1 /4" = Y-O" ELECTRICAL - POWER 1 /4" = Y-0" ELECTRICAL LEGEND DETAIL DESCRIPTION DUPLEX RECEPTACLE GFI DUPLEX RECEPTACLE - GFCI 'OLGFI DUPLEX RECEPTACLE - GFCI, ABOVE COUNTER A-1 BRANCH CIRCUIT HOME -RUN WITH CIRCUIT NUMBER Q JUNCTION BOX ELECTRICAL PANEL DISCONNECT - NON FUSED DISCONNECT - FUSED O 2X2 LAY -IN TROFFER El2X2 NIGHT LIGHT ❑❑ CEILING MOUNTED LIGHT/FAN COMBO FIXTURE EMERGENCY BATTERY PACK AND DUAL HEADS EXIT/EMERGENCY LIGHT W/ BATTERY PACK AND DUAL HEADS Q WALL MOUNTED OCCUPANCY SENSOR TOGGLE SWITCH SINGLE POLE SWITCH WITH COVER PLATE I GENERAL NOTES: I A. ALL WORK TO COMPLY TO ALLSTATE, LOCAL, NEC, & NFPA CODES. B. ELECTRICAL CONTRACTOR TO VISIT THE SITE PRIOR TO SUBMITTING A BID & INCLUDE IN THEIR BID ANY ITEM ANY ITEMS NECESSARY FOR A COMPLETE & OPERATIONAL SYSTEM. C. DRAWINGS ARE SCHEMATIC IN NATURE. ELECTRICAL CONTRACTOR IS TO ADD ANY ITEMS THAT ARE REQUIRED FOR A COMPLETE & OPERATIONAL SYSTEM IN THEIR PROPOSAL. D. ELECTRICAL CONTRACTOR IS TO COORDINATE THEIR INSTALLATION WITH THE OTHER TRADES. IF A CONFLICT OCCURS AND IT IS DUE TO THE ELECTRICAL CONTRACTOR'S LACK OF COORDINATION, ALL WORK INVOLVED IN RESOLVING THE CONFLICT WILL BE AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. E. ELECTRICAL CONTRACTOR TO FURNISH A TYPE WRITTEN PANEL SCHEDULE DESCRIBING EACH CIRCUIT AND WHAT LOCATION IT CONTROLS PER NEC 408.4 CODED NOTES: O 1. PROVIDE SHOW WINDOW DUPLEX RECEPTACLE AT NO MORE THAN 18'' ABOVE WINDOW. 2. LANDLORD TO PROVIDE 2" PVC EMPTY CONDUIT STUBBED HIGH ON WALL INTO SPACE FOR TELECOMMUNICATIONS WIRING FOR FUTURE TENANT. 3. EWH-1: 9.7 AMPS, 208V, 30 ELECTRIC WATER HEATER SUPPLIED BY PLUMBING CONTRACTOR. WIRED BY EC. EC SHALL PROVIDE SWITCH FOR DISCONNECT MEANS. PROVIDE (3) # 12, # 12G IN 3/4" CONDUIT FROM 15A/3P BREAKER IN PANEL'A'. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH PLUMBING CONTRACTOR PRIOR TO ROUGH -IN. MAKE FINAL CONNECTIONS 4. EC SHALL INSTALL OCCUPANCY SENSOR WALL SWITCH TO CONTROL RESTROOM LIGHT/FAN COMBO FIXTURE. SEE #3 DIAGRAM ON THIS DRAWING FOR WIRING. (LEVITON #OSS10-IDW OR EQUAL PROVIDE FACE PLATE). 5. NEW RTU-1 TO REPLACE OLD ROOFTOP UNIT. EC SHALL COORDINATE WITH MECHANICAL CONTRACTOR DEMOLITION OF OLD RTU. EC SHALL DE -ENERGIZE OLD UNIT AND REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE. NEW RTU-1: 51 MCA, 208V/3PH. PROVIDE (3) # 6, # 1 OG IN 1" CONDUIT FROM NEW 60/3P HACR BREAKER THROUGH FACTORY SUPPLIED DISC SWITCH TO UNIT. MAKE FINAL CONNECTION. ABBREVIATIONS (A) EXISTING TO BE ABANDONED HPC HIGH PRESSURE CONTACT SWITCH (D) EXISTING TO BE DEMOLISHED HZ HERTZ (E) EXISTING TO REMAIN IG ISOLATED GROUND (R) EXISTING TO BE RELOCATED IMC INTERMEDIATE METAL CONDUIT A AMPERE KVA KILOVOLT AMPERE AF AMP FUSED KW KILOWATT AS AMP SWITCH LTG LIGHTING OR LIGHT AFF ABOVE FINISHED FLOOR MCA MAXIMUM CURRENT AMPACITY AWG AMERICAN WIRE GAUGE MCB MAIN CIRCUIT BREAKER C CONDUIT MDP MAIN DISTRIBUTION PANEL CB CIRCUIT BREAKER MLO MAIN LUGS ONLY CKT CIRCUIT MOCP MAXIMUM OVERCURRENT PROTECTION CM CONSTRUCTION MANAGER MH METAL HALIDE DP DISTRIBUTION PANELBOARD MTS MANUAL TRANSFER SWITCH EB ELECTRONIC BALLAST NL NIGHTLIGHTING EC ELECTRICAL CONTRACTOR OCC OCCUPANCY EM EMERGENCY PB PULL BOX OR PUSH BUTTON EWC ELECTRIC WATER COOLER RECPT RECEPTACLE FA FIRE ALARM TC TIME CLOCK FLA FULL LOAD AMPS TYP TYPICAL G GROUND UNO UNLESS NOTED OTHERWISE GC GENERAL TRADES CONTRACTOR V VOLT GFCI GROUND FAULT CIRCUIT INTERRUPTER W WATT GEN GENERATOR WP WEATHERPROOF, NEMA 3R UNO HP IHORSEPOWER IXFMR ITRANSFORMIER L O A NEUTRAL WHT r RED I D POWER HOT BILK I T RED I PACK T o Lu J J ll:� Co m r ISOLATED RELAY DT-200 OCCUPANCY SENSOR WITH MANUAL -ON STANDARD SCHEMATIC RED RLY COM.' ORG N.O. BRN L-----------------LGT.LEVEL N.C. BLU OCCUPANCY YLW SENSORS USING -0 GRIN CTRL OUT. EIGHT WIRES MAN. SW WITH MANUAL -ON VIO +24V GRA COMMON *MOMENTARY SWITCH DT-200 WIRES NOTE: THE MANUAL ON FEATURE VIA A MOMENTARY SWITCH IS OPTIONAL. REFER TO THE INSTALLATION INSTRUCTION FOR ADDITIONAL INFORMATION. OCCUPANCY SENSOR WIRING DIAGRAM N.T.S. rn IN r, rl- ro N N !`_� rl_ �m0000 It n r. . .� =3 O 00 00 > �O L vi lfl lD 4A Z3 Ln a) ro Ln E 4-- 00 =5 O 1 U COPYRIGHT2018. ALLDRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE+ PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. z W 5 G Ln W N \ O = 0 5� G Z) Co 0 2 Oo Z)o J Q zm0 J N M Il� (Dw � L1J JUG 2� ' QQ �z �o V) O'�'a C) zo LL_�z �m W WV) Q U J Lu Z ~ <<q � � � w PROJECT NUMBER: W P GO07 ISSUE DATE PERMIT FEB. 01, 2018 I.171:111:11115 ELECTRICAL PLANS E 1 a 1 00 00 N SPECIFICATIONS - DIVISION 26 - ELECTRICAL GENERAL REQUIREMENTS 208Y/120V SYSTEM: BLACK, RED, BLUE & WHITE (NEUTRAL) 20 AMPERE #12 #12 #12 PROVIDE LUMINAIRES AND/OR LUMINAIRE OUTLET BOXES WITH HANGERS TO PROPERLY SUPPORT LUMINAIRE WEIGHT. EQUIPMENT GROUNDING: GREEN 25 AMPERE #10 #10 #10 ALL LUMINAIRES INSTALLED IN OR ON SUSPENDED CEILING SYSTEMS SHALL BE ANCHORED DIRECTLY TO THE BUILDING THE GENERAL PROVISIONS OF THE CONTRACT INCLUDING THE GENERAL AND SUPPLEMENTAL CONDITIONS AND ALL EQUIPMENT & SYSTEM IDENTIFICATION NOMENCLATURE SHOWN ON DRAWINGS OR LISTED HEREIN IS SHOWN FOR 30 AMPERE #10 #10 #10 STRUCTURAL SYSTEM ABOVE (ANCHORED PER NEC). SUCH ANCHORING SHALL BE INDEPENDENT OF THE CEILING GENERAL REQUIREMENTS APPLY TO THE WORK IN THIS SECTION. BEFORE SUBMITTING A BID, EXAMINE DOCUMENTS GENERAL DESIGN AND INSTALLATION REFERENCE ONLY. THE ACTUAL NAMEPLATE, ETC. NOMENCLATURE FOR THIS 35 AMPERE # 8 # 8 #10 SUPPORTSYSTEM. ALL LUMINAIRES SHALL BE INSTALLED PLUMB AND LEVEL. SUPPORT SURFACE MOUNTED LUMINAIRES OF ALL OTHER TRADES, VISIT THE SITE AND GET ACQUAINTED WITH ALL CONDITIONS THAT MAY IN ANY WAY PROJECT SHALL BE VERIFIED BY ELECTRICAL CONTRACTOR IN FIELD PRIOR TO FABRICATION AND WHERE APPLICABLE, 40 AMPERE # 8 # 8 #10 GREATER THAN 2 FEET IN LENGTH AT A POINT IN ADDITION TO THE OUTLET BOX LUMINAIRE STUD. WHATSOEVER AFFECT THE EXECUTION OF THIS CONTRACT. TAKE MEASUREMENTS AND BE RESPONSIBLE FOR EXACT SHALL BE AN EXTENSION OF EXISTING NOMENCLATURE USED ON THE SITE AS DETERMINED IN FIELD BY ELECTRICAL SIZE AND LOCATIONS OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF WORK. FIGURED DIMENSIONS ARE CONTRACTOR. MECHANICAL EQUIPMENT REASONABLY ACCURATE AND SHOULD GOVERN IN SETTING OUT WORK. WHERE DETAILED METHOD OF CONDUIT AND FITTINGS OUTLETS SHALL BE LOCATED APPROXIMATELY AS SHOWN ON THE PLANS AND SHALL BE WIRED TO PROVIDE INSTALLATION IS NOT INDICATED OR WHERE VARIATIONS EXIST BETWEEN DESCRIBED WORK AND APPROVED CONTROL OF OUTLETS INDICATED. ALL WIRES OF ANY ONE CIRCUIT SHALL BE RUN IN THE SAME CONDUIT. PRACTICE, DIRECTION OF THE OWNERS REPRESENTATIVE ON JOB SITE SHALL BE FOLLOWED. PROVIDE ALL CONDUIT AND OUTLET BOXES AS REQUIRED FOR ALL CONTROL WIRING AND THERMOSTATS. FURNISH NORMAL SYSTEM BRANCH CIRCUITS SHALL BE INSTALLED IN SEPARATE RACEWAYS FROM EMERGENCY SYSTEM TYPE AC/MC CABLE MAY BE UTILIZED ONLY IF NEC APPROVED AND IF APPROVED BY LOCAL AUTHORITY HAVING AND INSTALL POWER WIRING AND MAKE LINE CONNECTIONS TO ALL HEATING, VENTILATING AND AIR THE CONTRACT INCLUDES ALL ITEMS OF MATERIAL AND LABOR REQUIRED FOR THE COMPLETE INSTALLATION AND POWER. JURISDICTION AND IF INCLUDED IN THE APPLICATIONS DEFINED BELOW. CONDITIONING EQUIPMENT. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY DISCONNECTS TO FULL OPERATION OF THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND HEREINAFTER SPECIFIED. ALL OPERATE THE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM AS DESCRIBED ON DRAWINGS OF ALL OTHER MATERIALS AND METHODS SHALL BE IN ACCORDANCE WITH APPLICABLE CODES, REGULATIONS AND/OR ALL WIRING FOR DIFFERENT POWER VOLTAGES SHALL BE INSTALLED IN RACEWAY SYSTEMS SEPARATE FROM EACH 15 THROUGH 30 AMPERE BRANCH CIRCUIT WORK. THIS SHALL APPLY ONLY UNDER ALL OF THE FOLLOWING TRADES. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONTROL AND INTERLOCK WIRING AS SPECIFICALLY INDICATED ON THE DRAWINGS. ALL OTHER CONTROL WIRING REQUIRED FOR OPERATION OF THE SYSTEMS SHALL BE ORDINANCES AND MEET THE APPROVAL OF LOCAL INSPECTION AUTHORITY HAVING JURISDICTION. THE LATEST OTHER. CIRCUMSTANCES AND CONDITIONS. PROVIDED BY THE HEATING CONTRACTOR. EDITION OF THE NATIONAL ELECTRIC CODE SHALL BE THE MINIMUM REQUIREMENT FOR ALL WORK. EXAMINE THE DRAWINGS AND SPECIFICATIONS FOR COMPLIANCE WITH THE ABOVE CODES, REGULATIONS AND ORDINANCES AND BASE BID AND WORK ACCORDINGLY. OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS RELATED TO THIS ALL WIRING FOR THE VARIOUS ELECTRICAL SYSTEMS SHALL BE INSTALLED IN RACEWAY SYSTEMS SEPARATE FROM ONLY WHERE CONCEALED (ALL EXPOSED WIRING SHALL BE INSTALLED IN CONDUIT). ELECTRICAL CONTRACTOR SHALL EXAMINE THE APPROVED DRAWINGS OF ALL BRANCHES AND SHALL WIRE AND EACH OTHER. WORK. A CERTIFICATE OF APPROVAL FOR WORK FROM INSPECTION AUTHORITY SHALL BE GIVEN TO THE OWNER CONNECT ALL MOTORS, DISCONNECTS, CONTROL DEVICES AND OTHER ITEMS REQUIRING ELECTRICITY FOR BEFORE FINAL ACCEPTANCE WILL BE GIVEN BY OWNERS REPRESENTATIVE. ROUTE ALL CABLES PERPENDICULAR AND PARALLEL TO THE BUILDING ARCHITECTURAL OPERATION. THIS CONTRACTOR SHALL MAKE THE NECESSARY ELECTRICAL CONNECTIONS BETWEEN THE SPECIFIED ALL CONDUIT INSTALLED INDOORS SHALL BE GALVANIZED STEEL EMT MINIMUM ALL FITTINGS FOR SAME SHALL LINES/SURFACES/STRUCTURAL MEMBERS, KEEPING OFFSETS TO A MINIMUM AND FOLLOWING SURFACE EQUIPMENT AND THE JUNCTION BOX NEAR EQUIPMENT WITH FLEXIBLE METALLIC CONDUIT AND MATCHED ALL WORK, MATERIALS, AND EQUIPMENT SHALL HAVE A WARRANTY FOR THE DURATION OF THE INSTALLATION OR A BESET -SCREW COMPRESSION TYPE STEEL, WITH INSULATED THROATTS.S. UNLESS INDICATED OTHERWISE ON CONTOURS WHERE POSSIBLE. MAINTAIN A UNIFORM ELEVATION FOR ALL CABLE RUNS WHEREVER POSSIBLE. ALL CONNECTORS. NO FLEXIBLE CONDUIT SHALL BE EXPOSED IN FINISHED ROOMS. PERIOD OF 1 YEAR, WHICHEVER IS LESS, AFTER ACCEPTANCE OF THE WORK BY THE OWNER. ANY DEFECTIVE ITEMS IN DRAWINGS OR N OTHER PARTS OF THE ELECTRICAL SPECIFICATIONS. CABLES SHALL BE SUPPORTED/ANCHORED AT MAXIMUM 4 FOOT INTERVALS AND WITHIN 12" OF BOX OR OUTLET SHALL BE REMOVED AND REPLACED AT THE ELECTRICAL SUB -CONTRACTORS EXPENSE AND TO THE SATISFACTION OF AND SHALL NOT SAG. INSTALL CABLES IN A MANNER THAT PREVENTS OVERHEATING. CABLES SHALL BE THE OWNER. CONDUIT SHALL BE CLEANED INSIDE BEFORE ANY WIRES ARE PULLED. CONDUIT ENDS SHALL BE CAPPED AND FASTENED DIRECTLY TO THE STRUCTURE USING FACTORY CLAMPS/CLIPS SPECIFICALLY DESIGNED FOR THE PLUGGED WITH STANDARD ACCESSORIES AS SOON AS CONDUIT HAS BEEN PERMANENTLY INSTALLED. CONDUIT RESPECTIVE CABLE (CADDY OR EQUAL). PERFORM WORK UNDER THIS CONTRACT IN CLOSE HARMONY WITH OTHER CONTRACTORS SO COMPLETED WORK INSTALLED WITHOUT CONDUCTORS SHALL BE PROVIDED WITH SWEEP BENDS AND BALING WIRE FOR PULLING. SHALL PRESENT A NEAT AND WORKMANLIKE INSTALLATION. EXPOSED FINISHED MATERIALS AND EQUIPMENT SHALL BE OUTLET, JUNCTION AND SWITCHBOXES MISCELLANEOUS SPECIALTIES CAREFULLY CLEANED AND WIPED TO REMOVE GREASE, SMUDGES, DUST AND OTHER SPOTS AND LEFT SMOOTH AND ALL JOINTS SHALL BE MADE TIGHT WITH WATERTIGHT COUPLINGS MATCHING CONDUIT AND ALL CORNERS SHALL BE CLEAN. DURING THE PROGRESS OF THE WORK, THE ELECTRICAL SUB -CONTRACTOR SHALL CAREFULLY CLEAN UP MAKE WITH LONG RADIUS. THE ENDS OF ALL CONDUITS SHALL BE CUT SQUARE AND REAMED AND ALL JOINTS PROVIDE A COMPLETE WIRING SYSTEM TO KITCHEN EQUIPMENT. DETERMINE EXACT LOCATION, MOUNTING HEIGHT AFTER HIS MEN AND SHALL LEAVE THE PREMISES AND ALL PORTIONS OF THE BUILDING IN WHICH HE IS WORKING FREE BROUGHT TO A SHOULDER. CONDUIT SHALL BE CONTINUOUS BETWEEN OUTLETS TO MAKE A COMPLETE IN GENERAL, GANG TYPE OUTLET BOXES SHALL NOT BE USED. THE OUTLET BOX LOCATIONS INDICATED ON AND TERMINATION REQUIREMENTS FROM MANUFACTURERS EQUIPMENT SUBMITTALS. PROVIDE EITHER DIRECT OF DEBRIS AND IN A CLEAN AND SAFE CONDITION. INSTALLATION AND TO EFFECT A CONTINUOUS GROUND. SUITABLE SUPPORTS AND FASTENING SHALL BE PROVIDED DRAWINGS SHALL BE CONSIDERED APPROXIMATE, AND THEREFORE, IT SHALL BE INCUMBENT UPON THIS CONNECTIONS OR CORD & PLUG CONNECTIONS (INCLUDING CORDS, PLUGS AND RECEPTACLES) AS DETERMINED FOR CONDUIT. CONTRACTOR TO STUDY THE GENERAL CONSTRUCTION WITH RELATION TO SPACES AND EQUIPMENT SURROUNDING IN FIELD; VERIFY CASE BY CASE PRIOR TO ROUGH -IN. VERIFY ELECTRICAL RATINGS IN FIELD PRIOR TO ROUGH -IN. WHENEVER THE WORDS "CONTRACTOR", "THIS CONTRACTOR", ETC. APPEAR ON DRAWINGS OR IN THESE EACH OUTLET. ALL OUTLET, SWITCH AND JUNCTION BOXES SHALL BE MADE OF CODE GALVANIZED STEEL COMPLETE MAKE FINAL CONNECTIONS TO EQUIPMENT. SPECIFICATIONS FOR THE ELECTRICAL WORK, IT SHALL REFER TO THE ELECTRICAL SUB -CONTRACTOR. WHENEVER THE WITH RINGS AND SCREW COVER PLATES AND LOCATED WHERE SHOWN AND NOTED ON DRAWINGS. WHERE WORD "PROVIDE" APPEARS IN THESE DOCUMENTS, IT SHALL BE INTERPRETED TO MEAN "FURNISH & INSTALL". CONDUIT SHALL BE SUPPORTED BY APPROVED STRAPS, FASTENERS AND HANGERS. HANGERS SHALL BE SUSPENDED CONDUIT IS CONCEALED, BOXES SHALL NOT BE LESS THAN 4" SQUARE X 1-1/2" DEEP. ALL BOXES SHALL BE EQUIPPED FROM RODS. PERFORATED STRAPS WILL NOT BE ACCEPTABLE. FASTENERS SHALL BE LEAD EXPANSION SHIELDS IN WITH PROPER COVERS TO BRING FLUSH WITH FINISHED WALL SURFACE. BLOCK OR CONCRETE, TOGGLE BOLTS IN HOLLOW WALLS, MACHINE SCREWS ON METAL SURFACES AND WOOD THE EXACT MOUNTING HEIGHT OF OUTLETS SHALL BE DETERMINED IN THE FIELD WITH RELATION TO ARCHITECTURAL SCREWS ON WOOD CONSTRUCTION. ALL CONDUIT SHALL BE SUPPORTED INDEPENDENTLY FROM ALL OTHER DETAILS AND EQUIPMENT BEING SERVED. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE BUILDING SYSTEMS AND SHALL BE SUPPORTED DIRECTLY FROM STRUCTURAL COMPONENTS. WHERE DEFLECTION IS WHERE OUTLET BOXES OCCUR IN FACING TILE OR OTHER MATERIAL WHERE SUCH MATERIALS FORM THE FINISHED OUTLET LOCATION WITH EQUIPMENT. THE OWNERS REPRESENTATIVE SHALL BE PERMITTED TO RELOCATE ANY OUTLET EXPECTED, CONDUITS SHALL BE PROVIDED WITH EXPANSION FITTINGS WITH BONDING JUMPERS. CONDUITS PASSING WALL SURFACE, THE OPENING FOR THE BOX SHALL BE CUT NEATLY AND OF THE SIZE THAT THE COVER PLATE WILL PRIOR TO INSTALLATION WITHIN A 15 FOOT LIMIT AT NO ADDITIONAL CHARGE IN CONTRACT PRICE. ALL FASTENERS, THROUGH STRUCTURAL MEMBERS SHALL BE PROVIDED WITH STUB AND COUPLING OR SLEEVE IN THE MEMBER. COVER ALL PARTS OF THE OPENING. CONDULETS SHALL BE USED ON EXPOSED RACEWAYS. IN GENERAL, JUNCTION HANGERS AND METHODS OF HANGING EXPOSED WORK IN FINISHED AREAS SHALL BE SUBMITTED TO THE OWNERS BOXES SHALL BE FURNISHED AND REQUIRED BY THE NATIONAL ELECTRIC CODE, OF THE PROPER SIZES, AND SHALL BE REPRESENTATIVE FOR APPROVAL BEFORE INSTALLATION. CONSTRUCTED OF #12 GAUGE STEEL WITH REMOVABLE FRONT FASTENED ON WITH COUNTER SUNK HEAD SCREWS ALL RACEWAYS SHALL BE ENTIRELY FREE OF PLASTER, MORTAR, WATER AND OTHER FOREIGN MATTER. OR OTHER APPROVED MEANS. FOR SPECIAL APPLICATION, JUNCTION BOXES SHALL BE NOTED, DETAILED AND/OR THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER INSTRUCTION OF EACH SYSTEM TO THE SATISFACTION OF SIZED ON THE DRAWINGS OR IN THE FIELD AS REQUIRED. THE OWNERS REPRESENTATIVE. PROVIDE RIGID STEEL, HEAVY WALL, FULL WEIGHT, ZINC -COATED, THREADED TYPE CONDUITS (GROUNDED) THAT TURN UP FROM BELOW GRADE OR BELOW SLAB, EXCLUDING THE 90 DEGREE FITTINGS THAT CONNECT TO HEIGHT OF BOXES THE ELECTRICAL CONTRACTOR SHALL CONSULT THE PLUMBING, HEATING AND ARCHITECTURAL PLANS IN ALL HORIZONTAL CONDUITS BELOW GRADE OR SLAB. INSTANCES BEFORE INSTALLING HIS WORK SO THAT HIS PIPING WILL NOT INTERFERE WITH THOSE BRANCHES. IN THE PRIOR TO ROUGH -IN, VERIFY ALL BOX/DEVICE MOUNTING HEIGHTS AND LOCATIONS IN FIELD WITH OWNERS EVENT OF A CONFLICT, THIS CONTRACTOR SHALL REPORT TO THE OWNERS REPRESENTATIVE AT ONCE AND DO NO BOXES AND FITTINGS REPRESENTATIVE. IN GENERAL, WHERE NOT LOCATED AT COUNTER AREAS, THE HEIGHT OF BOXES FROM FINISHED FURTHER WORK UNTIL A SATISFACTORY ARRANGEMENT IS DECIDED UPON. ANY WORK DONE, OR EQUIPMENT FLOOR TO CENTER OF BOXES SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED ON PLANS: PLACED IN POSITION BY THIS CONTRACTOR, CREATING A CONFLICT IN VIOLATION HEREOF, SHALL BE READJUSTED TO THE SATISFACTION OF THE OWNERS REPRESENTATIVE AT THE EXPENSE OF THE CONTRACTOR. THE DECISION OF THE PROVIDE MINIMUM SIZE OF 4 INCHES SQUARE BY 1-1/2 INCHES DEEP FOR OUTLET BOXES AND JUNCTION BOXES. OWNERS REPRESENTATIVE SHALL BE FINAL IN REGARD TO CHANGES DUE TO CONFLICTING CONDITIONS. PROVIDE OUTLET BOX ACCESSORIES AS REQUIRED FOR EACH INSTALLATION, INCLUDING BOX SUPPORTS, MOUNTING SWITCHES: 48" CONTRACTOR SHALL COMPLETE HIS WORK OR ANY PART THEREOF AT SUCH TIME AS MAY BE DESIGNATED BY THE EARS AND BRACKETS, WALLBOARD HANGERS, BOX EXTENSION RINGS, FIXTURE STUDS, CABLE CLAMPS, AND METAL DEVICES AT SPECIAL HEIGHTS: AS DIRECTED INFIELD. OWNER, SO THAT IT CAN BE USED FOR TEMPORARY OR PERMANENT USE AND SUCH USE OF THE SYSTEM SHALL NOT BE STRAPS FOR SUPPORTING OUTLET BOXES, WHICH ARE COMPATIBLE WITH OUTLET BOXES BEING USED TO FULFILL RECEPTACLES: 18" (UNLESS COUNTER HEIGHT) CONSTRUED AS AN ACCEPTANCE OF SAME BY OWNER. INSTALLATION REQUIREMENTS FOR INDIVIDUAL WIRING SITUATIONS. PROVIDE WITH STAINLESS STEEL NUTS, BOLTS, TELEPHONE OUTLETS (DESK PHONE): 18" SCREWS AND WASHERS. TELEPHONE OUTLETS (WALL PHONE): 48" EXISTING CONDITIONS WIRE AND CABLE DATA CABLE OUTLETS: 18"CONTROL STATIONS: 48" WHERE THE TERM "DEMOLITION" IS USED HEREIN, INTERPRET IT TO MEAN "DEMOLITION" OR "SELECTIVE DEMOLITION" AS APPLICABLE. FURNISH AND INSTALL ALL NECESSARY CABLE OF THE SIZE AND TYPE INDICATED ON THE DRAWINGS OR SPECIFIED WIRING DEVICES PERFORM A DETAILED PRE -BID WALK-THROUGH FIELD INSPECTION TO REVIEW THE EXISTING STRUCTURES AND HEREINAFTER. ALL WIRE SHALL BE COPPER. ALL WIRING SHALL BE NEW. NO WIRE SMALLER THAN #12 AWG SHALL BE PREMISES, TO DETERMINE EXISTING CONDITIONS, AND TO DETERMINE SCOPE OF REQUIRED ELECTRICALLY RELATED INSTALLED UNLESS SPECIFICALLY DESIGNATED. USE OF #14 COLOR CODED WIRE WILL BE ALLOWED FOR CONTROL PROVIDE WALL SWITCHES THAT ARE FLUSH SELF -GROUNDING WITH GREEN GROUND SCREW AND COLOR CODED DEMOLITION WORK. INCLUDE APPLICABLE ACCESSIBLE CEILING CAVITY AREAS IN THIS INSPECTION. CIRCUITS ONLY. ALL CONDUCTORS SHALL BE COPPER. PROVIDE STRANDED CONDUCTORS FOR ALL SIZES UNLESS COVER, SNAP TOGGLE TYPE, BACK AND SIDE WIRED, SPECIFICATION GRADE. PROVIDE WALL SWITCHES RATED 20A, INDICATED OTHERWISE. 120/277 VOLTS, 1 HP AT 120V, A.C. QUIET TYPE. SINGLE POLE SWITCHES SHALL BE EQUAL TO LEVITON #1221-2 SERIES. IT IS NOT THE INTENT OF THESE THIS SECTION, OR OF DRAWINGS, THAT EXISTING CONDITIONS BE ACCURATELY DOUBLE -POLE SWITCHES SHALL BE EQUAL TO LEVITON #1222-2 SERIES. SHOWN. EXISTING ELECTRICAL WORK IS SHOWN TO A VERY LIMITED EXTENT ON DRAWINGS AND IS SHOWN FOR GENERAL PLANNING REFERENCE ONLY. LOCATIONS AND INFORMATION WERE DERIVED FROM CURSORY VISUAL PROVIDE THHN/THWN INSULATION FOR ALL CONDUCTORS NO. 8 AWG AND SMALLER. FOR ALL OTHER SIZES OBSERVATIONS OR FROM PORTIONS OF DOCUMENTS THAT WERE PREPARED FOR PREVIOUSLY INSTALLED WORK (NOT PROVIDE THW OR THHN/THWN INSULATION AS APPROPRIATE FOR THE LOCATIONS WHERE INSTALLED. PROVIDE PROVIDE DUPLEX AND SINGLE SPECIFICATION GRADE RECEPTACLES, 2-POLE, 3-WIRE GROUNDING, FROM RECORD DRAWINGS OR "AS-BUILTS"). COLOR CODED INSULATION/JACKET FOR PHASE IDENTIFICATION. ALL WIRES SHALL BE RATED AT 600 VOLTS. SELF -GROUNDING, GREEN GROUNDING SCREW, GROUND TERMINALS AND POLES INTERNALLY CONNECTED TO MOUNTING YOKE, COLOR CODED BASE, 20-AMPERES, 125-VOLTS, WITH METAL PLASTER EARS, BACK & SIDE WIRING, DO NOT REUSE REMOVED ELECTRICAL MATERIALS UNLESS SPECIFICALLY INDICATED IN PROJECT MANUAL OR ON TYPE AC AND MC CABLE SHALL BE FORMED FROM CONTINUOUS LENGTH OF SPIRALLY WOUND, INTERLOCKED NEMA CONFIGURATION 5-20R. PROVIDE DUPLEX RECEPTACLES EQUAL TO LEVITON #5362 SERIES. FOR RECEPTACLE DRAWINGS. EXISTING WIRING SYSTEMS MAY BE UTILIZED ONLY TO THE EXTENT INDICATED IN PROJECT MANUAL, OR ZINC -COATED OR GALVANIZED (INSIDE & OUTSIDE) STRIP STEEL. ALL CONDUCTORS SHALL BE RATED FOR 90 DEG. C. CIRCUITS PROTECTED WITH 15A BREAKERS, PROVIDE NEMA 5-15R EQUIVALENTS. ON DRAWINGS, OR AS DIRECTED BY OWNER'S REPRESENTATIVE IN FIELD. MINIMUM. PROVIDE WITH FULL PARITY SIZED GREEN INSULATED EQUIPMENT GROUND CONDUCTOR. PROVIDE LOCATE, IDENTIFY, AND PROTECT ELECTRICAL SERVICES PASSING THROUGH DEMOLITION AREAS AND SERVING COMPATIBLE STEEL FITTINGS WITH INTEGRAL RED PLASTIC INSULATED THROAT BUSHINGS, COMPLIANT WITH NEC 350-5. PROVIDE SELF -GROUNDING COMMERCIAL SPECIFICATION GRADE, DUPLEX RECEPTACLES, GROUND -FAULT CIRCUIT OTHER AREAS OUTSIDE THE DEMOLITION LIMITS. MAINTAIN SERVICES TO AREAS OUTSIDE DEMOLITION LIMITS. WHEN CABLES SHALL BE 90 DEG. C. RATED WITH ALL COMPONENTS AND FITTINGS LISTED FOR GROUNDING AND INTERRUPTERS; FEED-THRU TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON SINGLE SERVICES MUST BE INTERRUPTED, INSTALL TEMPORARY SERVICES FOR AFFECTED AREAS. COMPLIANT WITH THE FOLLOWING. CIRCUIT, GROUNDING TYPE UL-RATED 943, CLASS A, GROUP 1, SPECIFICATION GRADE, 20-AMPERES RATING (DEVICE & FEED-THRU), 125-VOLTS, 60 HZ; WITH SOLID-STATE GROUND -FAULT SENSING AND SIGNALING (MAXIMUM PROVIDE ELECTRICAL DEMOLITION WORK AS REQUIRED TO ACCOMMODATE PROJECT DEMOLITION AND AS UL STD.4 AND UL STD. 83. THRESHOLD OF 5MA AT 0.025 SECONDS MAXIMUM); EQUIP WITH 20-AMPERE PLUG CONFIGURATION, NEMA 5-20R. REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. ANSI E119 AND E814. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLES EQUAL TO LEVITON #8898 SERIES. REFER TO OWNER'S REPRESENTATIVE FOR DISPOSAL INSTRUCTIONS FOR ABANDONED ELECTRICAL MATERIALS NEC ARTICLES 250 AND 333. REMOVED DURING DEMOLITION AND THEREAFTER. NEATLY STORE ELECTRICAL MATERIALS THAT THE OWNER ELECTS SPECIAL PURPOSE RECEPTACLES SHALL BE OF THE SIZE, TYPE AND MANUFACTURER AS INDICATED ON THE PLANS OR TO RETAIN AT THE SITE AS DESIGNATED BY THE OWNER'S REPRESENTATIVE. LEGALLY DISPOSE OF MATERIALS THAT THE METHOD OF WIRING -POWER AS DETERMINED IN FIELD. REFER TO GROUNDING SECTION FOR SPECIAL RECEPTACLE GROUNDING REQUIREMENTS. OWNER ELECTS NOT TO RETAIN. AFFECTED EQUIPMENT/MATERIALS AREAS FOLLOWS. NEATLY DRESS ALL WORK. INSTALL ALL WORK PARALLEL AND PERPENDICULAR TO SURFACES OR EXPOSED ALL DEVICE WALLPLATES SHALL BE STANDARD SIZE; "MIDWAY", "OVERSIZED" ("JUMBO") OR "EXTRA DEEP" WALLPLATES SHALL NOT BE ACCEPTABLE. CONSTRUCT WITH METAL SCREWS FOR SECURING PLATES TO DEVICES; SCREW HEADS LUMINAIRES. STRUCTURAL MEMBERS, AND FOLLOW SURFACE CONTOURS, WHERE POSSIBLE. KEEP CONDUCTOR SPLICES TO COLORED TO MATCH FINISH OF PLATES. WALLPLATES IN FINISHED AREAS SHALL BE COMMERCIAL SPECIFICATION MINIMUM. INSTALL SPLICE AND TAP CONNECTORS WHICH POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH GRADE. WIRING DEVICES. AND INSULATION RATING THAN CONDUCTORS BEING SPLICED. USE SPLICE AND TAP CONNECTORS WHICH ARE COMPATIBLE WITH CONDUCTOR MATERIAL. ALL WIRES SHALL BE RUN CONTINUOUS FROM OUTLET TO DATA/COMMUNICATIONS DEVICES 8 EQUIPMENT. OUTLET/LUMINAIRE TO LUMINAIRE. INSULATION VALUE OF JOINTS TO BE 100% IN EXCESS OF WIRE. PROVIDE SUPPORTS, INSERTS, CUTTING AND PATCHING ADEQUATE LENGTH OF CONDUCTORS WITHIN ELECTRICAL ENCLOSURES AND TRAIN THE CONDUCTORS TO TERMINAL INTERIM AIR QUALITY (IAQ) WORK POINTS WITH NO EXCESS. BUNDLE MULTIPLE CONDUCTORS, WITH CONDUCTORS LARGER THAN NO 10 AWG CABLED THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING REQUIRED FOR THE ADMISSION OF HIS WORK. ANY PREVENT AIRBORNE DUST AND PARTICULATE MATTER RESULTING FROM ELECTRICAL WORK FROM ENTERING IN INDIVIDUAL CIRCUITS. MAKE TERMINATIONS SO THERE IS NO BARE CONDUCTOR AT THE TERMINAL. DAMAGE DONE BY THIS CONTRACTOR TO THE BUILDING DURING THE PROGRESS OF HIS WORK SHALL BE MADE OCCUPIED SPACES, AND FROM ENTERING AIR INTAKES TO OPERATING HVAC SYSTEMS. GOOD AT HIS OWN EXPENSE. ALL PATCHING SHALL BE DONE BY A SKILLED CRAFTSMAN IN THAT RESPECTIVE TRADE. KEEP CONDUCTOR SPLICES TO MINIMUM. PULL CONDUCTORS SIMULTANEOUSLY WHERE MORE THAN ONE IS BEING IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO SUPERVISE THE INSTALLATION OF, AND PAY FOR ALL MAKE REQUIRED ELECTRICAL OPENINGS THROUGH WALLS AND FLOORS IMMEDIATELY PRIOR TO INSTALLATION OF INSTALLED IN SAME RACEWAY. USE UL LISTED PULLING COMPOUND OR LUBRICANT, WHERE NECESSARY. INSTALL ADDITIONAL MEMBERS, WOOD OR METAL AND LABOR WHICH MAY BE REQUIRED TO SUPPORT ANY TYPE OF WORK. PROPERLY AND PERMANENTLY SEAL ELECTRICAL OPENINGS IMMEDIATELY AFTER INSTALLATION OF WORK. SPLICE AND TAP CONNECTORS WHICH POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION PERMANENT OR TEMPORARY ELECTRICAL APPARATUS EMPLOYED IN THE EXECUTION OF THIS CONTRACTORS WORK. PROVIDE TEMPORARY SEALS FOR APPLICATIONS WHERE PENETRATIONS ARE MADE BUT CAN NOT BE PERMANENTLY RATING THAN CONDUCTORS BEING SPLICED. USE SPLICE AND TAP CONNECTORS WHICH ARE COMPATIBLE WITH SEALED WITHIN FOUR HOURS. CONDUCTOR MATERIAL. INCREASE WIRE SIZES PER NEC TO OFFSET VOLTAGE DROP AS/IF REQUIRED. SEAL ALL NEW FLOOR, CEILING, WALL, SLAB, ETC. PENETRATIONS TO MATCH OR EXCEED EXISTING ASSEMBLY FIRE RATINGS. PROVIDE SLEEVE SEALS FOR ALL SLEEVES, PROVIDE SLEEVES FOR ALL PENETRATIONS. ALL PENETRATIONS OF MATERIALS AND EQUIPMENT NO WIRE SIZE SMALLER THAN NO. 12 SHALL BE USED FOR ANY BRANCH CIRCUIT UNLESS OTHERWISE NOTED ON PLANS FIRE -RATED OR SMOKE -RATED WALL, FLOORS CEILINGS, ETC. SHALL BE SEALED IMMEDIATELY AFTER RACEWAYS ARE FOR CONTROL CIRCUITS. LARGER SIZES SHALL BE USED WHERE REQUIRED AND/OR INDICATED ON THE PLANS. INSTALLED. ALL NEW ELECTRICALLY RELATED WORK SHALL BE SUPPORTED DIRECTLY FROM BUILDING STRUCTURAL ALL MATERIALS AND EQUIPMENT SHALL BE NEW. ALL MATERIALS, APPARATUS AND EQUIPMENT SHALL BEAR THE MEMBERS. NEW ELECTRICALLY RELATED WORK SHALL NOT BE SUPPORTED FROM DUCTWORK, DUCTWORK HANGER, UNDERWRITERS LABORATORIES INC., LABEL WHERE REGULARLY SUPPLIED. CERTAIN MANUFACTURERS OF MATERIAL PROVIDE THE FOLLOWING MINIMUM WIRE SIZES BASED ON DISTANCES FROM PANEL TO FIRST DEVICE OF A 15 OR 20 CEILING SUPPORTS, EXISTING CONDUIT SUPPORT, ETC. ALL CONDUITS (AND CABLE ASSEMBLIES, WHERE APPLICABLE) AND EQUIPMENT ARE SPECIFIED AND PLANS ARE DETAILED ACCORDING TO THIS MATERIAL. THIS CONTRACTOR AMPERE GENERAL LIGHTING OR RECEPTACLE BRANCH CIRCUIT. IN ADDITION TO UPSIZING CONDUCTORS AS SHALL BE ROUTED PARALLEL TO BUILDING STRUCTURAL MEMBERS. ANY AND ALL NONCOMPLYING WORK INSTALLED SHALL BASE HIS BID ON FURNISHING AND INSTALLING THIS MAKE OF MATERIAL AND EQUIPMENT. REQUIRED FOR VOLTAGE DROP, PROVIDE MINIMUM #10 AWG CONDUCTORS TO THE LAST DEVICE FOR BRANCH BY THE ELECTRICAL CONTRACTOR SHALL BE REMOVED AND REINSTALLED TO THE SATISFACTION OF THE OWNER'S CIRCUITS MORE THAN 150 FEET IN LENGTH. REPRESENTATIVE AND THE ENGINEER, AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. WHERE MORE THAN ONE MAKE OF MATERIAL OR EQUIPMENT IS SPECIFIED, THE CONTRACTOR SHALL STATE IN HIS BID WHICH MAKE HE PROPOSES TO FURNISH. SHOP DRAWINGS SHALL BE SUBMITTED ON MATERIAL AND EQUIPMENT TO DISTANCE AWG WIRE SIZES BE FURNISHED BY THE CONTRACTOR FOR ENGINEERS APPROVAL. THIS APPROVAL TO BE OBTAINED PRIOR TO UP TO 60 FEET #12 LUMINAIRES SHIPMENT OF EQUIPMENT. 61 TO 90 FEET #10 91 TO 150 FEET # 8 ALL RECESSED LUMINAIRES SHALL BE EQUIPPED WITH NECESSARY PLASTER FRAMES AND SURFACE TRIM. ALL ELECTRICAL IDENTIFICATION 151 TO 240 FEET # 6 RECESSED FLUORESCENT LUMINAIRES SHALL BE EQUIPPED AND SUITABLY CONSTRUCTED TO OPERATE WITH "P" RATED BALLASTS. ALL RECESS MOUNTED INCANDESCENT AND H.I.D. LUMINAIRESSHALL HAVE UL APPROVED THERMAL PROVIDE MANUFACTURERS STANDARD SELF-ADHESIVE VINYL TAPE NOT LESS THAN 3 MILS THICK BY 1-1/2" WIDE. PROTECTION PER LATEST EDITION OF NFPA/NEC. ALL JUNCTION BOXES AND SERVICEABLE COMPONENTS (BALLASTS, WHERE APPLICABLE, INSTALL ON ALL CONCEALED RACEWAYS AT CONNECTION TO ALL JUNCTION BOXES, PULL THERMAL PROTECTION DEVICES, FUSES, ETC.) FOR RECESSED LUMINAIRES SHALL BE READILY ACCESSIBLE FOR SERVICE BOXES, EQUIPMENT, WALL/FLOOR/ROOF PENETRATIONS, ETC. UNLESS OTHERWISE INDICATED OR REQUIRED BY PROVIDE THE FOLLOWING MINIMUM AWG CONDUCTOR SIZES FOR GENERAL BRANCH CIRCUITING THAT ARE NOT OR REPLACEMENT FROM BELOW THE CEILING, WITHOUT REMOVING ANY CEILING COMPONENTS (OTHER THAN TILES). GOVERNING REGULATIONS, PROVIDE ORANGE TAPE WITH BLACK LETTERS. PROVIDE CIRCUIT IDENTIFICATION BANDS INDICATED ON DRAWINGS, BASED ON USING COPPER CONDUCTORS. WHERE APPLICABLE INCREASE AS REQUIRED FOR ALL CABLES AND CONDUCTORS. PROVIDE MANUFACTURERS STANDARD COLOR CODING FOR TO ACCOMMODATE VOLTAGE DROP AND TO ACCOMMODATE SPECIAL CONDITIONS. DO NOT DERATE ANY PROVIDE LOW ENERGY SOLID STATE RAPID START ELECTRONIC FLUORESCENT LAMP BALLASTS SPECIFICALLY CABLE/CONDUCTOR JACKET AND/OR INSULATION FOR ALL CABLES AND CONDUCTORS OF ALL SYSTEMS. MATCH GROUNDED (NEUTRAL) CONDUCTORS. TEMPERATURE RATINGS LISTED BELOW PERTAIN TO BOTH WIRE AND DESIGNED FOR OPERATING LAMP TYPES INDICATED UNLESS NOTED OTHERWISE. FLUORESCENT BALLASTS SHALL BE IDENTIFICATION WITH MARKING SYSTEM USED IN EXISTING SYSTEMS SHOP DRAWINGS, CONTRACT DOCUMENTS, AND TERMINATIONS. MOTOROLA OR ADVANCE EQUAL (LESS THAN OR EQUAL TO 20% THD). ALL LUMINAIRES MAY CONTAIN EITHER SIMILAR PREVIOUSLY ESTABLISHED IDENTIFICATION FOR PROJECTS ELECTRICAL WORK. PROVIDE ON ALL SINGLE BALLASTS OR MULTIPLE BALLASTS AS REQUIRED TO FULFILL REQUIRED FUNCTION AND AS REQUIRED TO CONDUCTORS OF ALL SYSTEMS. COMPLY WITH CONSTRUCTION SCHEDULE. THE FOLLOWING INSULATION COLOR CODE SHALL BE USED FOR SYSTEM AND VOLTAGE IDENTIFICATION. THIS SHALL 60 DEG. C RATING 75 DEG. C RATING EQUIPT. GROUNDING FLUORESCENT LAMP COLOR TEMPERATURE SHALL BE AS INDICATED ON DRAWINGS OR AS DIRECTED IN FIELD. SOURCE BREAKER/FUSE AWG WIRE SIZE AWG WIRE SIZE AWG WIRE SIZE APPLY TO BOTH FEEDER AND BRANCH CIRCUIT WIRING. INTERCHANGE OF COLORS SHALL NOT BE PERMITTED. 15 AMPERE # #12 #12 • . L0 Ln • ro Ol r—I n ro N N � N M N > O ro �u on L 00 Z3 O 1 U n COPYRIGHT 2018. ALLDRAWII AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RE ARCHITECTURE + PLANNING L AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSE OF THE ARCHITECT. z uj Lu O �NN Oo 112L I ZI O z J co N m a Lu C:) Lu J U a z � I a a O rin w F_ C)I z �� >_z wUw z� U a void �i a m o < to rl U LL PROJECT NUMBER: W PGO07 SHEET: SPECIFICATIONS ELECTRICAL E791 RELEASED IFCR CONSTRUCTION at State and Ilmeail Endlen 0tp at Caimal DATE: 03/07/18 Nick Mishler