Loading...
HomeMy WebLinkAboutA000.4PLOTTED: March 1, 2018 / Rudolph Sanchez / 2450-BOURGES-MZ-BASE-EL-NC2G.DWG A3-NC2G 3FB.3Northern Craftsman 2G3 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule1900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2018 Suzette Schuette 06/13/2016 RIGHT BOURGES 2450.300.00.CPM LOT 27 02/12/2018SCALE:FRONT ELEVATION1/4" = 1'-0"- TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR \A1;9'-1{\H0.750000x;\S1#8;}" \A1; \A1;8'-2{\H0.750000x;\S7#8;}" \A1; \A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}" 6" FASCIA BOARD, PER SPEC HORIZONTAL SIDING, PER SPEC 18" TAPERED COLUMN,\PPER SPEC 10" FRIEZE, PER SPEC ROOF SHINGLES, PER SPEC 6" CORNER BOARD, PER SPEC 6" RAKE BOARD, PER SPEC ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC 6" TRIM, PER SPEC8" TRIM, PER SPEC SHAKE SIDING, PER SPEC 6" SILL TRIM, PER SPEC 6" FRIEZE, PER SPEC(2) 2020 FX BLACKED OUT3030 FX BLACKED OUT BRICK SOLDIER COURSE, PER SPEC \A1;12'-0" \A1;12'-0" 912912 912912 SCALE:ROOF PLAN1/8" = 1'-0"- 7:12 6:12 "A"3156ROOF AREA:SQ. FT. \A1;34'-0" \A1;4'-0" \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;1'-0"\PTYP. \A1;4'-0"\A1;4'-10"\A1;1'-0" \A1;1'-0"\PTYP. "B"202ROOF AREA:SQ. FT. \A1;3'-0" 6:12 7:12 9:129:12 5.5:12 9:129:12 3.5:12 6:12 SCALE:RIGHT ELEVATION1/8" = 1'-0"- 612 MASONRY WAINSCOT 126127 125.5 SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE \A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}" \A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}" \A1;MASONRY WRAP 126 127 125.5 123.5 TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE \A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}" \A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}" \A1;SCALE:REAR ELEVATION1/8" = 1'-0"- MASONRY WAINSCOT ELEVATION NC2G ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3156 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.21 5.26 4.66 46.89 11 0 AT EAVE 6.31 5.26 5.28 53.11 0 76.00 TOTAL (MIN)10.52 10.52 9.94 100.00 3 HIGH - RIDGE VENT 4.21 5.26 4.75 48.03 0 0 38.00 AT EAVE 6.31 5.26 5.14 51.97 0 74.00 TOTAL (MIN)10.52 10.52 9.89 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B"SQ FTG 202 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.27 0.34 0.42 46.56 1 0 AT EAVE 0.40 0.34 0.49 53.44 0 7.00 TOTAL (MIN)0.67 0.67 0.91 100.00 3 HIGH - RIDGE VENT 0.27 0.34 0.38 47.37 0 0 3.00 AT EAVE 0.40 0.34 0.42 52.63 0 6.00 TOTAL (MIN)0.67 0.67 0.79 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 03/06/18 Adam Schriner