3FB.3Northern Craftsman 2G3 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule1900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2018
Suzette Schuette 06/13/2016
RIGHT
BOURGES
2450.300.00.CPM
LOT 27
02/12/2018SCALE:FRONT ELEVATION1/4" = 1'-0"-
TOP OF FOUNDATION
TOP OF FLOOR
TOP OF PLATE
WINDOW HEAD HGT.
WINDOW HEAD HGT.
TOP OF PLATE
TOP OF FLOOR
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;
\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;7'-2{\H0.750000x;\S7#8;}"
6" FASCIA BOARD, PER SPEC
HORIZONTAL SIDING, PER SPEC
18" TAPERED COLUMN,\PPER SPEC
10" FRIEZE, PER SPEC
ROOF SHINGLES, PER SPEC
6" CORNER BOARD, PER SPEC
6" RAKE BOARD, PER SPEC
ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC
6" TRIM, PER SPEC8" TRIM, PER SPEC
SHAKE SIDING, PER SPEC
6" SILL TRIM, PER SPEC
6" FRIEZE, PER SPEC(2) 2020 FX BLACKED OUT3030 FX BLACKED OUT
BRICK SOLDIER COURSE, PER SPEC
\A1;12'-0"
\A1;12'-0"
912912
912912
SCALE:ROOF PLAN1/8" = 1'-0"-
7:12
6:12
"A"3156ROOF AREA:SQ. FT.
\A1;34'-0"
\A1;4'-0"
\pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
\A1;1'-0"\PTYP.
\A1;4'-0"\A1;4'-10"\A1;1'-0"
\A1;1'-0"\PTYP.
"B"202ROOF AREA:SQ. FT.
\A1;3'-0"
6:12
7:12
9:129:12
5.5:12 9:129:12
3.5:12
6:12
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
612
MASONRY WAINSCOT
126127
125.5
SCALE:LEFT ELEVATION1/8" = 1'-0"-
TOP OF FOUNDATION
TOP OF PLATE
TOP OF PLATE
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;MASONRY WRAP
126
127
125.5
123.5
TOP OF FOUNDATION
TOP OF PLATE
TOP OF PLATE
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;\A1;8'-1{\H0.750000x;\S1#8;}"\A1;\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;SCALE:REAR ELEVATION1/8" = 1'-0"-
MASONRY WAINSCOT
ELEVATION NC2G
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3156 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.21 5.26 4.66 46.89 11 0
AT EAVE 6.31 5.26 5.28 53.11 0 76.00
TOTAL (MIN)10.52 10.52 9.94 100.00
3
HIGH -
RIDGE VENT 4.21 5.26 4.75 48.03 0 0 38.00
AT EAVE 6.31 5.26 5.14 51.97 0 74.00
TOTAL (MIN)10.52 10.52 9.89 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "B"SQ FTG 202 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.27 0.34 0.42 46.56 1 0
AT EAVE 0.40 0.34 0.49 53.44 0 7.00
TOTAL (MIN)0.67 0.67 0.91 100.00
3
HIGH -
RIDGE VENT 0.27 0.34 0.38 47.37 0 0 3.00
AT EAVE 0.40 0.34 0.42 52.63 0 6.00
TOTAL (MIN)0.67 0.67 0.79 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
03/06/18
Adam Schriner