HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 116GTOKPCN 1WVNGVU Mark Function Price Model Airflow Range (CFM) Face Size (in.) Neck Size (in.) Color Remarks PD-1 Plaque Diffuser SPD 50-180 24 x 24 6Ø White 1,2,3 PD-2 Plaque Diffuser SPD 181-300 24 x 24 8Ø White 1,2,3 SDG-1 Spiral Duct Grille SDGE 50-175 10 x 4 N/A White 4 ER-1 Exhaust Register 530 0-100 7 3 4 x 7 3 4 6 x 6 White 1,2,3 ECR-1 Eggcrate Return 80 501-1500 24 x 12 22 x 10 White 1,2,3 LS-1 Linear Slot Diffuser SDS75 - 1 slot 1-100 24" 5"Ø By Architect 3 LS-2 Linear Slot Diffuser SDS75 - 1 slot 1-100 48" 5"Ø By Architect 3 LS-3 Linear Slot Diffuser SDS75 - 2 slot 101-180 48" 7"Ø By Architect 3 LS-4 Linear Slot Diffuser SDS100 - 2 slot 181-240 48" 8"Ø By Architect 3 LS-5 Linear Slot Diffuser SDS100 - 3 slot 241-310 48" 10"Ø By Architect 3 Notes: 1. Provide factory extended panel for any diffuser which is smaller than the grid in which it is installed. 2. Sound baffle by Sheet Metal Contractor. 3. Provide plaster frame for diffusers, registers and grilles installed in gypsum board. 4. Provide optional air scoop. &WEVNGUU 5RNKV #KT %QPFKVKQPGT Mark Area Served Model Cooling Capacity (BTU/hr) Heating Capacity (BTU/hr) Airflow (CFM) Electrical Connection Disconnect Remarks Outdoor Indoor Outdoor Indoor Voltage (V) Phase (Ø) MCA (Amps) DSAC-118 DSFC-118 IT Closet Mitsubishi MUy-GL12NA-U1 Mitsubishi MSY-GL12NA-U1 12,000 N/A 360 208 1 7.00 Manufacturer See Notes Notes: 1. Provide integral drain pan mounted condensate pump. 2. Provide flooded drain pan interlock. 3. Line voltage to outdoor unit. 4. Provide locking disconnect. 1-1/2" Round Flexible Connection 1" x 1/8" Band iron Washer 1/2" 1" x 1/8" Draw band 1/2" 5/16" Flange Bolt 4" on centers Rectangular Flexible Connection 1" Flange and hem Bolt 4" on centers 1" x 1/8" Band iron Washer Rivet 4" on centers Ductwork 1-1/2" Pocket slip Ductwork Flexible material as specified 1-1/2" Minimum to 3" maximum installed. 6" nominal with material taut Sheet metal as specified for ductwork Flanged connection on fan side Sheet metal as specified for ductwork Alternate position of bolt 1-1/2" Minimum to 3" maximum installed. 6" nominal with material taut Flanged connection on fan side Flexible material as specified 1" x 1/8" Draw band D (NGZKDNG %QPPGEVKQP M-XX Scale: None X Sheet metal box 1-1/2" duct wrap 1-1/2" duct wrap Sheet metal elbow Supply diffuser Application NOT Acceptable 12" x 12" supply diffuser Ceiling 24" x 24" supply diffuser Low pressure supply branch duct Collar with manual volume damper & lock Insulated flexible duct to supply diffuser Notes: Provide a 45 degree entry square-to-round fitting from low pressure supply branch duct when the supply diffuser branch size equals or exceeds the depth of the supply branch duct. Width shall equal round diffuser branch size, depth shall equal supply branch duct depth. Refer to supply diffuser plenum connection detail if guidelines of this detail can not be met due to physical limitations. A maximum length of 25'-0" of flexible duct is allowed in a single run. Secure flexible duct to supply diffuser elbow fitting with drawband Lay-in panel where required Secure flexible duct to supply diffuser elbow fitting with drawband Insulated flexible duct to supply diffuser Provide shoe 8" Min. tap fitting Ceiling D 5WRRN[ &KHHWUGT CPF (NGZKDNG &WEV %QPPGEVKQP M-XX Scale: None X Full size Cleanout plug Draw Through Coil Blow Through Coil Full size Cleanout plug Cleanout plug Route full size condensate drain pipe to nearest floor drain. Refer to plumbing drawings for floor drain locations. Unit manufacturers threaded drain pipe connection (typ) Cooling coil drain pan Drain line (bottom connection only) 1" greater than fan static pressure 1" greater than half of fan static pressure 1" greater than half of fan static pressure 1" greater than fan static pressure D %QPFGPUCVG &TCKP $NQY&TCYÄ6JTW %QKN M-XX Scale: None X Drain line (bottom connection only) Cooling coil drain pan Full size Full size Unit manufacturers threaded drain pipe connection (typ) Cleanout plug Route full size condensate drain pipe to nearest floor drain. Refer to plumbing drawings for floor drain locations. Fiber cap Fiber cant Stainless steel adjustable clamps Heavy gauge galvanized steel with continuous welded corner seams 1 1/2" rigid fiberglass insulation 1 1/2" wood nailer Stepped polyvinyl boot D 2KRG %WTD M-XX Scale: None X More than 30° 30° or less V.D. 45° Boottap fitting Duct offset Use radius for more than 30° Use mitered for 30° or less Duct offset 90° Square Elbow Branch off main Turning vanes 90° Radiused Elbow H H 2H D .QY 8GNQEKV[ 5JGGV /GVCN (KVVKPIU M-XX Scale: None X Minimum 1" wide clamp. Detail 2 Maximum flexible duct length shall be 5'-0". Wire support. Detail 1 Detail 3 Notes: 1. Metallic flexible ductwork shall be attached using a minimum of three (3) #8 sheet metal screws equally spaced around the ductwork circumference. Ductwork larger than 12" shall have a minimum of five (5) #8 sheet metal crews. Screws shall be located at least 1/2" from the ductwork end. 2. Non-metallic flexible ductwork shall be secured to the sleeve or collar using a draw band. If the ductwork collar exceeds 12", the draw band must be positioned behind a bead on the metal collar. 3. Insulation and vapor barriers present on factory-fabricated ductwork shall be fitted over the core connection and shall be supplementally secured with a draw band. 4. Flexible ductwork sealing shall be a class "B" seal for low pressure ductwork. 5. Support system shall not damage or cause out-of-round shape. 6. Flexible ductwork shall be a maximum of 5'-0" in length and shall NOT be used as an elbow. Maximum sag shall be 1/2" per foot of support spacing. Strap bracing shall be provided at a maximum of 3'-0" on centers. 1" Band clamp with wire. (Optional) D +PUWNCVGF (NGZKDNG &WEVYQTM M-XX Scale: None X Ceiling Washer with black neoprene pad on underside 1" Black rigid insulation board Wire support attached to structure 8" min. Eggcrate type return grille 12" all 4 sides D 1RGP 2NGPWO 4GVWTP )TKNNG M-XX Scale: None D *KIJÄ9CNN &WEVNGUU 5RNKV X M-XX Scale: None X Condensate drain up thru wall cavity. Refer to "P" Series drawings. Provide integral, drain pan mounted, condensate pump detection unit. Refrigerant piping up thru wall cavity. High-Wall type ductless split FCU. Mount FCU high on wall. Condensate drain down thru wall cavity. Refer to "P" Series drawings. Notes: 1. Install all components per Manufacturer's installation instructions. 2. Fan coils shall have a flooded drain pan interlock. 3. Refrigerant lines and condensate drains shall be insulated. Refrigerant lineset and condensate drain in wall cavity Provide piston type condensate pump like Sauerman SI3100 with detection unit located in FCU drain pan. ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. c 2018 BLACKLINE STUDIO ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 4 00 INDIANAPOLIS, INDIANA 4 6204 BLACKLINESTUDIO.NET 317.803.7900 CERTIFICATION: CHECKED BY: DRAWN BY: MEP ENGINEER THE ENGINEERING COLLABORATIVE 24 10 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, INDIANA 4 624 1 WWW.TEC-MEP.COM 317.636.3941 # Date Description P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R 12411 Pennsylvania St. Carmel, Indiana 46032 Permit Set JANUARY 17, 2018 Encore on Penn - Permit Set 01.17.18 First Floor Office Build-Out: Suites M601 HVAC SCHEDULES & DETAILS XXX XXX 03/07/18 Nick Mishler