HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 12A.0 B.0 C.0 D.0 E.0 F.0 G.0 H.0 I.0 2.0 1.0 3.0 4.0 5.0 6.0 CONFERENCE ROOM 111 OFFICE 112 OFFICE 119 IT CLOSET 118 OFFICE 117 UNISEX RR 116 KITCHENETTE SUITE 120 ENTRY 120 SMALL CONFERENCE 122 LARGE CONFERENCE 123 WAITING 121 FUTURE TENANT SUITE 100 100 OPEN OFFICE 113 ST101 STAIR 1 102 VESTIBULE ST102 EV100 ELEVATOR STAIR 2 101 UTILITY ALTERNATE BID 'W1' 'C1' 'E1' 'C1' 'C1' 'C1' 'E1' ' UNISEX RR 115 'X1' 'X1' 'L1' 'L1' 'L1' 'L1' 'L1' ' 'X1' 'C2' 'C2' 'E1' 'E1' 'E1' 'E1' 'L1' 114 'W1' 'C2' 'C2' 'C2' 'C2' 'C2' 'C2' 'C2' 'P2' 'P2' 'C2' 'C2' 'C2' 'C2' 'C2' 'C2' 'C2' 'C2' 'P2' 'C2' 'C2' 'C2' 'C2' 'X1' 'P3' 'P3' 'P4' 'P4' 'P4' 'P-12' 'P-12' 'P-16' 'P-16' 'P-16' 'P-16' 'L1' 'L1' 'L1' 'L1' 'L1' 'L1' 'P-16' 'E1' 'C2' 'C2' 'C2' 'C2' 'C2' 'L2' 'L2' 8 LD1-12 via "LC1" LD1-14 LD1-28 Note: Unless otherwise noted on plan, connect all exit signs (fixture type 'X1') and emergency lighting units (fixture type 'E1') to the room lighting circuit the sign and/or the emergency lighting unit is serving (ahead of any local switching means). )GPGTCN 0QVGU All 120 volt, 20 amp circuits over 60' in length shall be #10 AWG, over 95' shall be #8, over 145' shall be #6. Contractor shall coordinate with all other trades to avoid conflicts of space. Contractor shall coordinate the exact location of all devices with all other trades prior to rough-in. Exact location to be determined in the field. Contractor shall coordinate with the mechanical and plumbing contractors for exact locations of equipment prior to rough-in. Refer to sheet EI701 for details and symbols. Refer to sheet EI601 electrical riser diagram. Refer to sheets EI601 and EI602 for electrical schedules. Shared neutrals shall not be permitted. Note "H" clips are not acceptable for junction box supporting. Switches shall be a maximum +48" A.F.F. to the top of the device unless otherwise noted. Receptacles, telephone outlets, and television outlets shall be a minimum of +18" A.F.F. to the bottom of the device unless otherwise noted. Where devices are installed in fire walls, the boxes shall be rated and sealed for installation in a fire wall. Provide HACR circuit breakers for all HVAC and refrigeration equipment. All light fixtures marked '/ (Emergency) shall be on a switched circuit and have an emergency battery pack. All light fixtures marked 0. (Night Light) shall be on a non-switched circuit. All light fixtures marked '/0. (Emergency/Night Light) shall be on a non-switched circuit and have an emergency battery pack. Provide plenum rated cable/wire/conduit as required. Coordinate with mechanical contractor. A. B. C. D. E. F. G. H. J. K. L. M. N. P. Q. R. Note: E.C. shall comply with the IBC in regards to fire rated membrane penetrations. Utilize means of fire rated junction boxes, "putty pads", fire blocking and offsetting. 2NCP 0QVGU Contractor shall provide and install a 2-pole contactor "LC1" for general lighting in the Owner's specified location. Contactor "LC1" shall be controlled by digital time switch 1P and 1HH. Digital time switch shall have integral manual override control. 8 S. ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. c 2018 BLACKLINE STUDIO ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 4 00 INDIANAPOLIS, INDIANA 4 6204 BLACKLINESTUDIO.NET 317.803.7900 CERTIFICATION: CHECKED BY: DRAWN BY: MEP ENGINEER THE ENGINEERING COLLABORATIVE 24 10 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, INDIANA 4 624 1 WWW.TEC-MEP.COM 317.636.3941 # Date Description P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R 12411 Pennsylvania St. Carmel, Indiana 46032 Permit Set JANUARY 17, 2018 Encore on Penn - Permit Set 01.17.18 First Floor Office Build-Out: Suites E101 FIRST FLOOR LIGHTING PLAN SLH ALB 3/16" = 1'-0" 1 FIRST FLOOR LIGHTING PLAN 03/07/18 Nick Mishler