HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 13A.0 B.0 C.0 D.0 E.0 F.0 G.0 H.0 I.0
2.0
1.0
3.0
4.0
5.0
6.0
CONFERENCE ROOM
111
OFFICE
112
OFFICE
119
IT CLOSET
118
OFFICE
117
UNISEX RR
115
UNISEX RR
116
KITCHENETTE
SUITE 120 ENTRY
120
SMALL CONFERENCE
122
LARGE CONFERENCE
123
WAITING
121
FUTURE TENANT SUITE
100
100
OPEN OFFICE
113
ST101
STAIR 1
102
VESTIBULE
ST102
EV100
ELEVATOR
STAIR 2
101
UTILITY
92 SF
ALTERNATE
BID
+36"
LD1-1
+48" +48"
1
+60"
+60"
+60"
+60"
1
1
J
J
P
D
2
3
P
2 3
J
J
P
D
4
5
J
J
P
D
4
5
J
J
P
D
2
3
J
J
P
D 2
3
+60"
+60"
J
6
J J
D
7
+46"
LD1-2
LD1-3
LD1-3
LD1-6
LD1-5
LD1-7
114
+46"
LD1-8
+46"
LD1-8
LD1-4
WH-A
LD1-(39,41)
LD1-36
LD1-36
LD1-36
LD1-42
LD1-38
LD1-38
LD1-38
LD1-38
LD1-38
LD1-40
LD1-40
LD1-40
LD1-40
LD1-9
LD1-9
LD1-9
LD1-9
LD1-9
LD1-9
LD1-11
LD1-11
LD1-11
LD1-10
LD1-10
LD1-10
LD1-10
LD1-13
LD1-13
LD1-13
LD1-13
LD1-13
FCU-1-5
LD1-(31,33)
FCU-1-4
LD1-(31,33)
FCU-1-8
LD1-(31,33)
FCU-1-7
LD1-(31,33)
FCU-1-13
FCU-1-12 LD1-(35,37)
LD1-(35,37)
FCU-1-11
LD1-(35,37)
FCU-1-10
LD1-(35,37)
Panel "LD1"
Panel "LD1A"
LD1A-2,4,6,8
LD1A-10,12,14,16
LD1A-18,20,22,24
LD1A-17,19,21,23
LD1A-9,11,13,15
LD1A-1,3,5,7
)GPGTCN 0QVGU
All 120 volt, 20 amp circuits over 60' in length shall be
#10 AWG, over 95' shall be #8, over 145' shall be #6.
Contractor shall coordinate with all other trades to avoid
conflicts of space.
Contractor shall coordinate the exact location of all
devices with all other trades prior to rough-in. Exact
location to be determined in the field.
Contractor shall coordinate with the mechanical and
plumbing contractors for exact locations of equipment
prior to rough-in.
Refer to sheet EI701 for details and symbols.
Refer to sheet EI601 electrical riser diagram.
Refer to sheets EI601 and EI602 for electrical schedules.
Shared neutrals shall not be permitted.
Note "H" clips are not acceptable for junction box
supporting.
Switches shall be a maximum +48" A.F.F. to the top of
the device unless otherwise noted.
Receptacles, telephone outlets, and television outlets
shall be a minimum of +18" A.F.F. to the bottom of the
device unless otherwise noted.
Where devices are installed in fire walls, the boxes shall
be rated and sealed for installation in a fire wall.
Provide HACR circuit breakers for all HVAC and
refrigeration equipment.
All light fixtures marked '/ (Emergency) shall be on a
switched circuit and have an emergency battery pack.
All light fixtures marked 0. (Night Light) shall be on a
non-switched circuit.
All light fixtures marked '/0. (Emergency/Night Light)
shall be on a non-switched circuit and have an
emergency battery pack.
Provide plenum rated cable/wire/conduit as required.
Coordinate with mechanical contractor.
A.
B.
C.
D.
E.
F.
G.
H.
J.
K.
L.
M.
N.
P.
Q.
R.
Note:
E.C. shall comply with the IBC in regards
to fire rated membrane penetrations.
Utilize means of fire rated junction boxes,
"putty pads", fire blocking and offsetting.
2NCP 0QVGU
Provide and install a flush mounted floor box for furniture.
Floor box shall have divider to separate line voltage and
low voltage. Provide a 1" conduit to each data location.
Cut, patch and repair floor in kind where applicable.
Coordinate furniture electrical requirements prior to
rough-in.
Power feed at wall for furniture systems. Provide power
whip. Coordinate requirements with furniture vendor
prior to rough-in.
Voice/data rough-in at wall for furniture systems. Provide
a grommet coverplate. Coordinate requirements with
furniture vendor prior to rough-in.
Power feed at floor for furniture systems. Provide power
whip. Coordinate requirements with furniture vendor
prior to rough-in.
Voice/data rough-in at floor for furniture systems.
Provide a grommet coverplate. Coordinate requirements
with furniture vendor prior to rough-in.
Provide and install a recessed junction box in wall for
connection to branding signage. Verify exact sign
requirements, verify exact height with Architect, and
coordinate with wall structure prior to rough-in. Circuit
LD1-8. Coordinate control with Owner prior to rough-in.
Install receptacle in cabinetry above microwave.
Coordinate exact height prior to rough-in.
1
S.
2
3
4
5
6
7
ALL INFORMATION CONTAINED IN THIS
DOCUMENT IS CONSIDERED TO BE BOTH
CONFIDENTIAL AND PROPRIETARY
INTELLECTUAL PROPERTY OF BLACKLINE
STUDIO AND SHALL NOT BE COPIED,
REPRODUCED, DISTRIBUTED OR ASSIGNED TO
A THIRD PARTY WITHOUT PRIOR WRITTEN
CONSENT OF BLACKLINE STUDIO.
UNAUTHORIZED USE OF THESE DOCUMENTS IS
NOT PERMITTED.
c 2018 BLACKLINE STUDIO
ARCHITECT
BLACKLINE
1 N MERIDIAN ST, SUITE 4 00
INDIANAPOLIS, INDIANA 4 6204
BLACKLINESTUDIO.NET
317.803.7900
CERTIFICATION:
CHECKED BY:
DRAWN BY:
MEP ENGINEER
THE ENGINEERING COLLABORATIVE
24 10 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, INDIANA 4 624 1
WWW.TEC-MEP.COM
317.636.3941
# Date Description
P
R
O
F
E
S
S
I
O
N
A
L
E
N
G
N
I
E
E
R
S
A
M
U
E
L
L.
H
U
R
T
I
N
D
I
A
N
A
0
N
P E 1 6
o .
10 0 87
S T A T E O F
R
E
T
E
G
I
S
D
E
R
12411 Pennsylvania St.
Carmel, Indiana 46032
Permit Set
JANUARY 17, 2018
Encore on Penn - Permit Set 01.17.18
First Floor Office Build-Out: Suites
E201
FIRST FLOOR POWER PLAN
SLH
ALB
3/16" = 1'-0"
1 FIRST FLOOR POWER PLAN
03/07/18
Nick Mishler