Loading...
HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 141 NO SCALE Rec. Total = 1 Pole = 2 Pole = 3 Pole Legend Light Equip. Total Demand (KW) Heat A/C Other Total Demand Amps = 133± Demand load (KW) Connected load (KW) Wire Size: Fed From: Conduit: Feeder Calculated ± Light Other Wire: 4 Remarks 225 120/208 Amps: Phase: Voltage: 3 Heat <Load (KW)> Rec. A/C Equip. Mounting: Location: Other 1 Pole 20 AMP U.O.N. 1 Cir. No. Cir. No. A/C <Load (KW)> Equip. Heat Rec. Restroom Alcove Light Copper Recessed Bus: Main: Main Circuit Breaker Remarks 2 3 5 7 9 11 13 15 17 19 4 6 8 10 12 14 16 18 20 21 23 25 27 29 31 33 35 37 39 41 22 24 26 28 30 32 34 36 38 40 42 2CPGN .& 47.9 WH-A Receptacle Television Panel "LD1A" 120/208V., 3Ø,4W. 100 Amp M.L.O. 4#4/O,1#4,21 2"C. Restroom Alcove To existing meter center ELECTRICAL RISER DIAGRAM Existing Meter Center Building Exterior Refrigerator 1.2 1.5 Microwave = GFCI circuit breaker Notes: G G Television 1.2 1.0 1.0 IT Receptacle IT Receptacle 1.6 Future Copier 1.2 Dishwasher 1.5 Signage 2.5 20 G Receptacle Receptacle 1.2 .6 1.0 .8 Alternate Bid Only Receptacle Receptacle Receptacle .8 Receptacle .6 1.2 1.2 FCUs 15 FCUs 15 2.3 2.3 6.9 Rec. Total = 1 Pole = 2 Pole = 3 Pole Legend Light Equip. Total Demand (KW) Heat A/C Other Total Demand Amps = 53± Demand load (KW) Connected load (KW) Wire Size: Fed From: Conduit: Feeder Calculated ± Light Other Wire: 4 Remarks 100 120/208 Amps: Phase: Voltage: 3 Heat <Load (KW)> Rec. A/C Equip. Mounting: Location: Other 1 Pole 20 AMP U.O.N. 1 Cir. No. Cir. No. A/C <Load (KW)> Equip. Heat Rec. Restroom Alcove Light Copper Recessed Bus: Main: Main Lug Only Remarks 2 3 5 7 9 11 13 15 17 19 4 6 8 10 12 14 16 18 20 21 23 25 27 29 22 24 26 28 30 2CPGN .&# 19.2 Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System Furniture System .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 .8 Spare Spare Spare Spare Spare Spare 100 Panel "LD1A" Panel "LD1" 120/208V., 3Ø,4W. 225 Amp M.C.B. 9.6 9.6 9.6 9.6 19.2 19.2 .9 Lighting Lighting .7 Lighting 1.4 4#3,1#8,11 4"C. Utilize a spare meter base (field verify exact location). Provide and install a 225 Amp branch breaker (service entrance rated) as required if branch breaker is not present. 1.0 Lighting Contactor "LC1" Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare Spare 6.9 4.6 4.6 3.0 3.0 6.5 6.5 22.4 4.5 22.4 4.5 4.5 25.4 4.6 13.4 ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. c 2018 BLACKLINE STUDIO ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 4 00 INDIANAPOLIS, INDIANA 4 6204 BLACKLINESTUDIO.NET 317.803.7900 CERTIFICATION: CHECKED BY: DRAWN BY: MEP ENGINEER THE ENGINEERING COLLABORATIVE 24 10 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, INDIANA 4 624 1 WWW.TEC-MEP.COM 317.636.3941 # Date Description P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R 12411 Pennsylvania St. Carmel, Indiana 46032 Permit Set JANUARY 17, 2018 Encore on Penn - Permit Set 01.17.18 First Floor Office Build-Out: Suites E601 ELECTRICAL RISER DIAGRAM & SCHEDULES SLH ALB 03/07/18 Nick Mishler