HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 16A.0 B.0 C.0 D.0 E.0 F.0 G.0 H.0 I.0 2.0 1.0 3.0 4.0 5.0 6.0 ST101 STAIR 1 EV100 ELEVATOR 102 VESTIBULE ST102 STAIR 2 101 UTILITY 92 SF Exist. cleanout Exist. 6"S Exist. 6"S up Exist. 4"W up Exist. 4"V up Exist. 4"W Exist. cleanout Exist. Exist. 4"W cleanout Exist. 4"W Exist. cleanout Exist. cleanout Exist. 4"W Exist. 1 1 2"CW tap Exist. 2"CW Exist. 2"CW Exist. 1 1 2"CW tap Exist. 3"W Exist. 3 4"CW Exist. water heater 1 WC-1H WC-1H L-1H L-1H SK-1H RB-A WH-A, mount above ceiling 1 2 2"W 2 3"W 1"CW 3 Exist. floor drain 1 2"CW 1 2"HW Vertical pipe drop out of bottom of horizontal pipe Vertical pipe rise out of top of horizontal pipe Shutoff valve in pipe 90° Elbow down (drop in pipe) 90° Elbow up (rise in pipe) Clean out in floor CO Sanitary below grade or slab (W) Vent piping (V) 2NWODKPI 5[ODQNU CPF #DDTGXKCVKQPU Cold water piping (CW) Hot water return piping (HWR) Balancing valve in pipe Check valve in pipe Hot water piping (HW) 2NWODKPI (KZVWTG 5EJGFWNG Mark No. Description HW CW W V Pipe Connections (in) Model Numbers Acceptable Manufacturers WATER CLOSET - 1.28 GPF, Vitreous china, floor mtd., siphon jet, flush tank, elongated bowl. Open front seat less cover. Chrome plated brass supply. Loose key stop. +18" A.F.F. to top of seat to suit ADA. Flush handle to be on wide side of stall. MaP score: 800 grams or better. WC-1H - 1 2 3 2 KOHLER, SLOAN, TOTO, ZURN CHURCHPLUMBTECH #295C BEMIS, CENTOCO, AMERICAN STANDARD #215AA.104 AMERICAN STANDARD #0356.015 LAVATORY - Vitreous china, wall hung. Faucet: 1.5 GPM, single hole, lever handle, flat plate strainer. Accessories: Cast brass trap w/ co., loose key stops, chrome plated supplies, offset tailpiece, protective pipe and valve coverings, floor mounted carrier with concealed arm support. Mount @34" to rim, to suit ADA. ASSE 1070 mixing valve. L-1H 1 2 1 2 1 1 2 1 1 4 KOHLER, SLOAN, TOTO, ZURN ZURN #Z1231-EZ J.R. SMITH, WADE TRUEBRO #103 E-Z MCGUIRE, PLUMBEREX, ZURN GROHEKOHLER #34271001 AMERICAN STANDARD, SINK - Cabinet mounted, self-rimming, 18 GA stainless steel, one 6" deep bowl. Faucet: 1.75 GPM, Gooseneck, swivel spout, single lever. Accessories: Cast brass p-trap w/ co, loose key stops and chrome plated supplies, protective pipe and valve coverings, bucket strainer. SK-1H 1 2 1 2 1 1 2 1 1 2 JUST #SL-ADA-1815-A-GR ELKAY, FRANKE TRUEBRO #103 E-Z MCGUIRE, PLUMBEREX, ZURN GROHE #32665001 AMERICAN STANDARD, KOHLER RB-A REFRIGERATOR ICE MAKER UTILITY BOX - GUY GRAY #BIM875 1 2 - - OATEY, WATER-TITE WATER HEATER - Electric, shelf mounted, 19 gal. storage, 2.5 kW, BRADFORD WHITE #LE120L3-3 208V., 1Ø, energy saver. Overflow pan. Thermal expansion tank. Set outlet temperature to 140°F. WH-A - - LOCHINVAR, RHEEM, STATE, A.O. SMITH 3 4 3 4 WATER-TITE #HP 2022 MUSTEE, OATEY AMTROL #ST-5 A.O. SMITH, TACO 3 4 3 MV-A 4 MIXING VALVE - ASSE 1017. Thermostatically controlled, temperature and pressure compensated. Provide with unions, check stops, shut off valve & thermometer. Set outlet temperature to 110°F. - - LAWLER #84008-61-15 BRADLEY, LEONARD, SYMMONS A. All fittings, piping, fixtures, materials, etc. to meet the current Safe Drinking Water Act with all of its amendments and the Reduction of Lead in Drinking water Act. B. All work shall comply with all national, state, local codes and ordinances pertaining to the work in this project. C. All plumbing fixtures shall be supplied with individual water supply stops and code approved traps. Exposed piping shall be chrome plated. D. All plumbing fixtures shall be installed with approved backflow prevention devices. E. No piping shall pass directly over electrical power distribution cabinets, panelboards, etc. Contractor to coordinate panel locations prior to piping installation. F. DO NOT USE CELLULAR CORE PVC. G. All plumbing vents to be a minimum of 10'-0" from any air intake. Coordinate locations with HVAC plans. H. Single runouts to plumbing fixtures shall be the same size as on the plumbing fixture schedule unless otherwise noted. I. Concealed gas piping shall be constructed in accordance with code without unions, tubing fittings or running threads. J. Gas lines run on roof to be supported by Roof Top Blox or similar and equal. DO NOT USE LUMBER FOR GAS PIPING SUPPORT. K. Dry-pipe fire protection system shall be used in all areas subject to freezing. L. All waste, water, vent, gas and condensate lines shown to be connected to their associated fixture/equipment, unless noted otherwise. All equipment and systems shown must be complete and usable upon completion of project. All connections and installations to be per the manufacturer's requirements. )GPGTCN 0QVGU Connect new waste line to nearest active waste line of equal or larger size. Field verify exact size, location, material and elevation of existing waste line, prior to start of work. Neatly saw-cut existing slab along entire path of waste line. Repair slab in-kind, ready for finish. Connect new water line to existing tap. Field verify exact size, location and material of existing tap, prior to start of work. 2NCP 0QVGU 1 2 3 Extend drain to nearest code approved discharge point. 3 4"CW Wall bracket, if not provided by mfgr., shall be constructed of angle iron suitable for support of unit. Thermometer ASME T&P relief valve Mixing valve (MV-B) 3 4"HW Thermal expansion tank similar and equal to Amtrol #ST-5. Support as necessary. CW main NOTE: Details shown here are typical only and may not be complete. Contractor shall provide all material and labor necessary for the configuration, piping and accessories required to operate this system in the manner intended with complete safety. Overflow pan ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. c 2018 BLACKLINE STUDIO ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 4 00 INDIANAPOLIS, INDIANA 4 6204 BLACKLINESTUDIO.NET 317.803.7900 CERTIFICATION: CHECKED BY: DRAWN BY: MEP ENGINEER THE ENGINEERING COLLABORATIVE 24 10 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, INDIANA 4 624 1 WWW.TEC-MEP.COM 317.636.3941 # Date Description P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R 12411 Pennsylvania St. Carmel, Indiana 46032 Permit Set JANUARY 17, 2018 Encore on Penn - Permit Set 01.17.18 First Floor Office Build-Out: Suites P101 FIRST FLOOR PLUMBING PLAN SLH GJR 3/16" = 1'-0" 1 FIRST FLOOR PLUMBING PLAN NTS 2 WATER HEATER DETAIL 03/07/18 Nick Mishler