HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 16A.0 B.0 C.0 D.0 E.0 F.0 G.0 H.0 I.0
2.0
1.0
3.0
4.0
5.0
6.0
ST101
STAIR 1
EV100
ELEVATOR
102
VESTIBULE
ST102
STAIR 2
101
UTILITY
92 SF
Exist.
cleanout
Exist.
6"S
Exist.
6"S up
Exist.
4"W up
Exist.
4"V up
Exist.
4"W
Exist.
cleanout
Exist.
Exist. 4"W
cleanout
Exist.
4"W
Exist.
cleanout
Exist.
cleanout
Exist.
4"W
Exist.
1
1
2"CW tap
Exist.
2"CW
Exist.
2"CW
Exist.
1
1
2"CW tap
Exist.
3"W
Exist.
3
4"CW
Exist. water
heater
1
WC-1H WC-1H
L-1H L-1H
SK-1H
RB-A
WH-A, mount
above ceiling
1
2 2"W
2 3"W
1"CW 3
Exist.
floor drain
1
2"CW
1
2"HW
Vertical pipe drop out of bottom of
horizontal pipe
Vertical pipe rise out of top of horizontal
pipe
Shutoff valve in pipe
90° Elbow down (drop in pipe)
90° Elbow up (rise in pipe)
Clean out in floor
CO
Sanitary below grade or slab (W)
Vent piping (V)
2NWODKPI 5[ODQNU CPF #DDTGXKCVKQPU
Cold water piping (CW)
Hot water return piping (HWR)
Balancing valve in pipe
Check valve in pipe
Hot water piping (HW)
2NWODKPI (KZVWTG 5EJGFWNG
Mark
No.
Description
HW CW W V
Pipe Connections (in)
Model Numbers Acceptable Manufacturers
WATER CLOSET - 1.28 GPF, Vitreous china, floor mtd., siphon
jet, flush tank, elongated bowl. Open front seat less cover.
Chrome plated brass supply. Loose key stop. +18" A.F.F. to top
of seat to suit ADA. Flush handle to be on wide side of stall.
MaP score: 800 grams or better.
WC-1H -
1
2 3 2
KOHLER, SLOAN, TOTO, ZURN
CHURCHPLUMBTECH #295C BEMIS, CENTOCO,
AMERICAN STANDARD #215AA.104
AMERICAN STANDARD #0356.015
LAVATORY - Vitreous china, wall hung. Faucet: 1.5 GPM, single
hole, lever handle, flat plate strainer. Accessories: Cast brass trap
w/ co., loose key stops, chrome plated supplies, offset tailpiece,
protective pipe and valve coverings, floor mounted carrier with
concealed arm support. Mount @34" to rim, to suit ADA. ASSE
1070 mixing valve.
L-1H
1
2
1
2 1
1
2 1
1
4
KOHLER, SLOAN, TOTO, ZURN
ZURN #Z1231-EZ J.R. SMITH, WADE
TRUEBRO #103 E-Z MCGUIRE, PLUMBEREX, ZURN
GROHEKOHLER #34271001 AMERICAN STANDARD,
SINK - Cabinet mounted, self-rimming, 18 GA stainless steel, one 6"
deep bowl. Faucet: 1.75 GPM, Gooseneck, swivel spout, single
lever. Accessories: Cast brass p-trap w/ co, loose key stops and
chrome plated supplies, protective pipe and valve coverings, bucket
strainer.
SK-1H 1
2
1
2 1
1
2 1
1
2
JUST #SL-ADA-1815-A-GR ELKAY, FRANKE
TRUEBRO #103 E-Z MCGUIRE, PLUMBEREX, ZURN
GROHE #32665001 AMERICAN STANDARD, KOHLER
RB-A REFRIGERATOR ICE MAKER UTILITY BOX - GUY GRAY #BIM875
1
2 - - OATEY, WATER-TITE
WATER HEATER - Electric, shelf mounted, 19 gal. storage, 2.5 kW, BRADFORD WHITE #LE120L3-3
208V., 1Ø, energy saver. Overflow pan. Thermal expansion tank.
Set outlet temperature to 140°F.
WH-A - -
LOCHINVAR, RHEEM, STATE, A.O. SMITH
3
4
3
4
WATER-TITE #HP 2022 MUSTEE, OATEY
AMTROL #ST-5 A.O. SMITH, TACO
3
4
3
MV-A 4
MIXING VALVE - ASSE 1017. Thermostatically controlled,
temperature and pressure compensated. Provide with unions,
check stops, shut off valve & thermometer. Set outlet temperature
to 110°F.
- - LAWLER #84008-61-15 BRADLEY, LEONARD, SYMMONS
A. All fittings, piping, fixtures, materials, etc. to meet the
current Safe Drinking Water Act with all of its
amendments and the Reduction of Lead in Drinking
water Act.
B. All work shall comply with all national, state, local codes
and ordinances pertaining to the work in this project.
C. All plumbing fixtures shall be supplied with individual
water supply stops and code approved traps. Exposed
piping shall be chrome plated.
D. All plumbing fixtures shall be installed with approved
backflow prevention devices.
E. No piping shall pass directly over electrical power
distribution cabinets, panelboards, etc. Contractor to
coordinate panel locations prior to piping installation.
F. DO NOT USE CELLULAR CORE PVC.
G. All plumbing vents to be a minimum of 10'-0" from any air
intake. Coordinate locations with HVAC plans.
H. Single runouts to plumbing fixtures shall be the same
size as on the plumbing fixture schedule unless
otherwise noted.
I. Concealed gas piping shall be constructed in accordance
with code without unions, tubing fittings or running
threads.
J. Gas lines run on roof to be supported by Roof Top Blox
or similar and equal. DO NOT USE LUMBER FOR GAS
PIPING SUPPORT.
K. Dry-pipe fire protection system shall be used in all areas
subject to freezing.
L. All waste, water, vent, gas and condensate lines shown
to be connected to their associated fixture/equipment,
unless noted otherwise. All equipment and systems
shown must be complete and usable upon completion of
project. All connections and installations to be per the
manufacturer's requirements.
)GPGTCN 0QVGU
Connect new waste line to nearest active waste line of
equal or larger size. Field verify exact size, location,
material and elevation of existing waste line, prior to start
of work.
Neatly saw-cut existing slab along entire path of waste
line. Repair slab in-kind, ready for finish.
Connect new water line to existing tap. Field verify exact
size, location and material of existing tap, prior to start of
work.
2NCP 0QVGU
1
2
3
Extend drain to
nearest code
approved
discharge point.
3
4"CW
Wall bracket, if not provided
by mfgr., shall be constructed
of angle iron suitable for
support of unit.
Thermometer
ASME T&P
relief valve
Mixing valve
(MV-B)
3
4"HW
Thermal expansion
tank similar and equal
to Amtrol #ST-5.
Support as necessary.
CW main
NOTE:
Details shown here are typical only and may not be complete. Contractor shall provide all
material and labor necessary for the configuration, piping and accessories required to
operate this system in the manner intended with complete safety.
Overflow pan
ALL INFORMATION CONTAINED IN THIS
DOCUMENT IS CONSIDERED TO BE BOTH
CONFIDENTIAL AND PROPRIETARY
INTELLECTUAL PROPERTY OF BLACKLINE
STUDIO AND SHALL NOT BE COPIED,
REPRODUCED, DISTRIBUTED OR ASSIGNED TO
A THIRD PARTY WITHOUT PRIOR WRITTEN
CONSENT OF BLACKLINE STUDIO.
UNAUTHORIZED USE OF THESE DOCUMENTS IS
NOT PERMITTED.
c 2018 BLACKLINE STUDIO
ARCHITECT
BLACKLINE
1 N MERIDIAN ST, SUITE 4 00
INDIANAPOLIS, INDIANA 4 6204
BLACKLINESTUDIO.NET
317.803.7900
CERTIFICATION:
CHECKED BY:
DRAWN BY:
MEP ENGINEER
THE ENGINEERING COLLABORATIVE
24 10 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, INDIANA 4 624 1
WWW.TEC-MEP.COM
317.636.3941
# Date Description
P
R
O
F
E
S
S
I
O
N
A
L
E
N
G
N
I
E
E
R
S
A
M
U
E
L
L.
H
U
R
T
I
N
D
I
A
N
A
0
N
P E 1 6
o .
10 0 87
S T A T E O F
R
E
T
E
G
I
S
D
E
R
12411 Pennsylvania St.
Carmel, Indiana 46032
Permit Set
JANUARY 17, 2018
Encore on Penn - Permit Set 01.17.18
First Floor Office Build-Out: Suites
P101
FIRST FLOOR PLUMBING PLAN
SLH
GJR
3/16" = 1'-0"
1 FIRST FLOOR PLUMBING PLAN
NTS
2 WATER HEATER DETAIL
03/07/18
Nick Mishler