HomeMy WebLinkAboutEncore on Penn_First Floor Bui10 & 120_CONSTRUCTION DRAWI... 4A.0 B.0 C.0 D.0 E.0 F.0 G.0 H.0 I.0
2.0
1.0
3.0
4.0
5.0
A901 6.0
2
12' - 0"
GB-1
10' - 6"
APC-1
9' - 0"
APC-1
12' - 0"
GB-1
12' - 0"
GB-1
12' - 0"
GB-1
9' - 0"
GB-1
9' - 0"
APC-1
9' - 0"
APC-1
9' - 0"
APC-1
10' - 6"
APC-1
10' - 6"
APC-1
1' - 0"
1' - 0"
1' - 0"
1' - 0"
1' - 0"
ALTERNATE BID
10' - 6"
APC-2
1
2
2
2
2
2
3
A110
4
A110
4
A110
Sim
3
A110
Sim
1' - 0"
1' - 0" 1' - 0"
10' - 6"
APC-2
NOT IN SCOPE
NOT IN SCOPE
EQ EQ EQ EQ
4' - 0"
1
1 1 1
1
1 1 1
1
1
1
2' - 0" EQ EQ EQ 2' - 0"
EQ EQ
3' - 4" 3' - 4"
EQ EQ
9' - 0"
GB-1
3' - 4"
5
A110
12' - 0"
GB-1
3
A101
3
A101
Sim
CONFERENCE ROOM
111
SUITE 110 ENTRY
1 10
OFFICE
1 12
OFFICE
119
OFFICE
117
KITCHENETTE
114
OPEN OFFICE
113
UNISEX RESTROOM
115
UNISEX RESTROOM
1 16
IT CLOSET
118
3
ALIGN
3' - 2"
3' - 7"
3
A101
Sim
3' - 4"
INTERIOR CEILING TYPES LEGEND
BEVELED TEGULAR
ACOUSTICAL CEILING
PANELS.
ACOUSTICAL PANEL
CEILING SUSPENSION
WIRE. DO NOT
ATTACH TO DECK.
APC-1
2x2 Grid System
15/16" ACOUSTICAL
PANEL CEILING
SUSPENSION GRID (WHITE).
5/8" GB TYPICAL
3 5/8" 20 GA. METAL
STUD FRAMING @
16" OC
CORNER BEAD FINISH,
TYPICAL
5/8" SAG-RESISTANT GB
CEILING ELEVATION
CALLOUTS ARE TO THE
GB-1 BOTTOM OF GB
GENERAL CEILING PLAN NOTES
THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION
DRAWINGS.
A. ACOUSTIC PANEL CEILING SYSTEMS ARE CENTERED IN ROOMS UNLESS NOTED OTHERWISE.
B. COMPLY WITH ASTM C 636, ASTM E 580, AND SEISMIC DESIGN REQUIREMENTS INDICATED,
PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND CISCA'S "CEILING SYSTEMS
HANDBOOK."
C. MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL PANELS TO
BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING. AVOID USING LESS-
THAN-HALF-WIDTH PANELS AT BORDERS.
D. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS, PLUMB AND FREE
FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM. SPLAY
HANGERS ONLY WHERE REQUIRED AND, IF PERMITTED WITH FIRE-RESISTANCE-RATED
CEILINGS, TO MISS OBSTRUCTIONS; OFFSET RESULTING HORIZONTAL FORCES BY BRACING,
COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. WHERE WIDTH OF DUCTS AND
OTHER CONSTRUCTION WITHIN CEILING PLENUM PRODUCES HANGER SPACINGS THAT
INTERFERE WITH LOCATION OF HANGERS, USE TRAPEZES OR EQUIVALENT DEVICES. WHEN
STEEL FRAMING DOES NOT PERMIT INSTALLATION OF HANGER WIRES AT SPACING
REQUIRED, INSTALL CARRYING CHANNELS OR OTHER SUPPLEMENTAL SUPPORT FOR
ATTACHMENT OF HANGER WIRES.
E. INSTALL EDGE MOLDINGS AND TRIM OF TYPE INDICATED AT PERIMETER OF ACOUSTICAL
CEILING AREA AND WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL PANELS.
SCREW ATTACH MOLDINGS TO SUBSTRATE AT INTERVALS NOT MORE THAN 16 INCHES (400
MM) O.C. AND NOT MORE THAN 3 INCHES (75 MM) FROM ENDS, LEVELING WITH CEILING
SUSPENSION SYSTEM TO A TOLERANCE OF 1/8 INCH IN 12 FEET (3.2 MM IN 3.6 M). MITER
CORNERS ACCURATELY AND CONNECT SECURELY.
F. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW AND
ACCORDING TO ASTM C 840: LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO
VIEW UNLESS OTHERWISE INDICATED.
2.0
CEILING MOUNT
ROLLER SHADE
EXISTING
CURTAINWALL
EXISTING STRUCTURE
1' - 0"
EXISTING
EXTERIOR WALL
CONSTRUCTION
12'-0" A.F.F.
GB-1
10'-6" A.F.F.
APC-1
SECOND FLOOR
15'-0"
P1
05 40 00.03
05 40 00.03
09 29 00.02
09 29 00.02
09 51 13.01
09 51 13.03
6.0
CEILING MOUNT
ROLLER SHADE
EXISTING
CURTAINWALL
EXISTING
EXTERIOR WALL
CONSTRUCTION
12'-0" A.F.F.
GB-1
SECOND FLOOR
15'-0"
ALIGN WITH COLUMN
BUMPOUT BEYOND
9 1/4"
EXPOSED
STRUCTURE
EXISTING STRUCTURE
P1
P4
09 29 00.02
05 40 00.03
09 29 00.02
05 40 00.01
H.0
12'-0" A.F.F.
GB-1
SECOND FLOOR
15'-0"
EXISTING
CURTAINWALL
CEILING MOUNT
ROLLER SHADE
EXISTING EXTERIOR
WALL CONSTRUTION
EXISTING BRICK
BEYOND
09 29 00.02
05 40 00.03
05 40 00.01
P1
07 92 00.01
CENTER GYP. BRD.
ON BEAM
P4
R
T
AR19900111
A
C
R
H
C
E
T
I
STATE OF
B
T
T
O
C
S
No.
T
S
I
G
E
R
E
R
E
D
N
E
T
R
A
E
P
K
S
N
I
I
A
N
A
D
N
I
ALL INFORMATION CONTAINED IN THIS
DOCUMENT IS CONSIDERED TO BE BOTH
CONFIDENTIAL AND PROPRIETARY
INTELLECTUAL PROPERTY OF BLACKLINE
STUDIO AND SHALL NOT BE COPIED,
REPRODUCED, DISTRIBUTED OR ASSIGNED TO
A THIRD PARTY WITHOUT PRIOR WRITTEN
CONSENT OF BLACKLINE STUDIO.
UNAUTHORIZED USE OF THESE DOCUMENTS IS
NOT PERMITTED.
c 2018 BLACKLINE STUDIO
ARCHITECT
BLACKLINE
1 N MERIDIAN ST, SUITE 400
INDIANAPOLIS, INDIANA 46204
BLACKLINESTUDIO.NET
317.8 03.7900
CERTIFICATION:
CHECKED BY:
DRAWN BY:
MEP ENGINEER
THE ENGINEERING COLLABORATIVE
2410 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, INDIANA 46241
TEC-MEP.COM
317.636.3941
1/18/2018 8:37:58 AM C:\Users\emaher\Documents\Encore Sotheby's Build-Out_maher@blacklinestudio.net.rvt
A110
RCP - FIRST FLOOR
Encore on Penn - Permit Set 01.17.18
First Floor Office Build-Out: Suites
12411 Pennsylvania St.
Carmel, Indiana 46032
COPYRIGHT 2014
Permit Set
January 17, 2018
SBP
ERM
# Date Description
3/16" = 1'-0"
1 FIRST FLOOR REFLECTED CEILING PLAN
CEILING SCHEDULE
Type
Mark Description Manufacturer Model
APC-1 2 x 2 Acoustic Panel
Ceiling System
ARMSTRONG FINE FISSURED WHITE 2'x2'
TILES WITH TEGULAR EDGE
(#932). CONTRACTOR SERIES.
APC-2 2 x 2 Acoustic Panel
Ceiling System
ARMSTRONG FINE FISSURED WHITE 2'x2'
TILES WITH TEGULAR EDGE
(#932). CONTRACTOR SERIES.
USE 6" AXIOM CLASSIC TRIM
AT EXPOSED EDGES.
GB-1 Gypsum Board over Metal
Stud Framing Ceiling
System
1 1/2" = 1'-0"
4 SECTION DETAIL - ROLLER SHADE @ CURTAINWALL POCKET (TYP.) 1 1/2" = 1'-0"
3 SECTION DETAIL - ROLLER SHADE @ EXPOSED CLG BULKHEAD (TYP.)
CEILING PLAN NOTES
Number Desciption
1 ROLLER SHADE - BASIS OF DESIGN: HUNTER DOUGLAS RB 500 WITH STANDARD #3
ALUMINUM FASCIA. COLOR TO BE SELECTED BY THE ARCHITECT FROM RANGE OF
STANDARD AVAILABILITY.
2 EXPOSED STRUCTURE. PAINT EXPOSED STRUCTURE FROM EXTERIOR WALL TO 4'-0" PASSED
EDGE OF FLOATING CEILING BELOW.
3 BULKHEAD TO EXTEND TO DECK ABOVE.
1 1/2" = 1'-0"
5 ROLLER SHADE @ OPEN OFFICE EAST WALL
REFERENCED KEYED NOTES - PER SHEET
05 40 00.01 1-5/8" STEEL STUD FRAMING.
05 40 00.03 3-5/8" STEEL STUD FRAMING.
07 92 00.01 SEALANT JOINT.
09 29 00.02 5/8" GYPSUM BOARD.
09 51 13.01 24x24 PRELUDE 15/16" SUSPENSION GRID w/ ACOUSTIC CEILING TILES.
09 51 13.03 15/16" ARMSTRONG TEGULAR TRANSITION MOLDING.TAPE, SAND, MUD
AND PAINT.
03/07/18
Nick Mishler