HomeMy WebLinkAbout04060104 Building PlansJ�~�
-
'
I-- � 01, -1
VAPok
REATF-D RATE
li6t#OA-
K \/F- tJ
VAP*
'P IfOLF
m U
-MU
- eallewrar raynoc,
10,A
PERIMETER DRAIN IS TO ~�
tSj $�� ��� DROPERTY AIN TO SIMEA ON Is TSO
1 n 1 y BTAMED BY 1354
\ 2oo.ao; j
I25' UTILITY AND DRAINAGE EASEMENT
857.5
J 1 INV.
i � 860.0
J
O.INV.
esa.5
/ 4' SUBSURFACE PERIMETER
�c INV,
DRAIN (SEE DETAIL) �a/ / " 880.41
SURROUNDS ALL 4 SIDES
S.D.R.-35 iNV.
01
860.0
/ 861,0
j INV.
�..� + �Y ,� / p9 / /� s5ao
i INV. '� �S
858.5 "��
INV.
/A�DNPERFORATED PIPING FROM
_BOX TO D -LAT. (TYP.)
4' P.V.C.
INK DIST.
861.0 BOX
INV.
p 856.0
$4.2
1000 GALLON
----f �, DOSING TANK /
19
865 `_'
CONC.
DRIVE
GAR.
868.33
a -'c•
ALLON
F.F.EIFY.- e69.60
/ �TiC THANK
BSMT.- 859.50 g
0
65.6
8 e,so P 89.0
i
oo�
/J09/ CROOKED WICK LANE
LEGEND:
�' E 99.99 EXISTING GRADE (BEFORE CONST.)
SCALE: 1 30 P 99.99 PROPOSED GRADE (AFTER CONST.) a FIELD TILE
P 99.99 PROPOSED GRADE (AFTER CONST.
871 /" " EXISTING CONTOUR
EXISTING STORM SEVER
LOT 8
SPRING RUN ESTATES
SECTION ONE
INST. #9431
P.B. #2, PAGE #272
PLOT PLAN
� PREPARED FOR:
� � DESIGNSMITH, INC.
CARMEL .
INDIANA
PROPOSED STORM SEN£R
..._....C.rr..CNINE weI�Is a
■um an
on ■■■\:1■rrRRMN .CC�I�..i ..�.■
�.��.Croommil�'lummm...C.0 ■
■....r.l/...s��I►.wI.i.CC.■.o.....�I.wf.an on C
s1AI�i omm"�siIIulmol�!w/111�II�...iM>11�IIMI��.A ■
..rr..■�i►�.■.>I�.►.o.�cwiw�r..rin 111.0 .
soon CNo .19■800 klq CCCCCCCCCCCCCCC
CCCCCCCCCCCa �CCCCrCCCCCCCCCWON
CCCCCCICCCCC10811 CI�CCCC1110111
CCCCCCCCCCCCC�lkiC�CCCCCCCCC:i 0CCC
CCCCCCCCCCCCCCI CCCCCCCCCC
.>r.an I ...Mellon ones �I.an swiw..Cr..CC
CCCCOWN a CCCC� lCCCCCCowns no on ON
CCCCCC CCCCCC�
ON 0 Nunn onCCCCCC
I,
HIGH WATER ALARM LIGHT & HORN
SHALL BE ON A SEPARATE CIRCUIT
PUMP COVER & PEDESTAL ANNELO MIRED TU A HIGH WATER CONTROL
PLATFORM TO BE PROVIDED PAiN HASEMfIET OF HOUSE
BY MANUFACTURER
TOP OF STATION r 885.0 A '�JUNCTION BOX
r- FINISH GRADE �+ e84.5
IDS SHALL TO POWER SUPPLY
360 x 4a'
2" T -GUIDE BAR PRECAST MANHOLE OPEN]
BOTH ENDS OR EQUAL X
LIFT CHAIN I I _1 --SAL WATERTIGHT
4'. P.V.C. INLET
WE
B.
B. HP . 4/10
IDN - 10 "
(SEE PUMP CURVE)
1000 GALLON DOSING TANK WITH
SEPTIC TANK EFFLUENT PUMP
N -T --S
EXISTING GRADE
�-TOPSOIL 40
CLEAN
GRAVEL
TYPICAL PERIMETER DRAIN X --SEC,
N-- T --S
BARRIER MATERIAL a' STRAW L EARTH FILL
OR SYNTHEIC FILTER FABRIC
1. Requirements for absorption system:
a. Trenches shall be constructed 3' wide maximum
b. A minimum 12' of washed gravel shall surround the distribution laterals, as shown.
c. Absorption field -A minimum of 800 LF. of distribution lateral.
d. 7.5' minimum spacing -center of lateral to center of lateral
2 Absorption field lateral specifications
a. Must be at least 4' In diameter & meet A.S.T.M. D-2729 or A.S.T. F810-83 specifications.
b. The pipe must have perforations with the equivalent total opening as a comparable the laid with
1/4 open Joints per foot of tile. with the following provisions:
I. Three rows of holes
11. 1/2' to, 1/4" diameter holes with
1/2M holes at 2-1/4« or closer spacing
5/8 holes at 3-1/2* or closer spacing
1/4- holes at 5" or closer spacing
III. Equal separation of rows around the circumference
c. The pipe must be delivered In straight (unrolled) lengths.
3. Gravity sewer must be P.V.C. SDR -35 and meet A.S.T.M.-D 3034 specifications for 4' pipe.
4. System as designed and shown is done with the intention of the system being Installed at minimum depths.
5. No clay fill material will be placed over absorption field. Natural ground line to remain as much as
possible.
6. Finish grading over- absorption field will be done to obtain positive surface drainage away from field. Any
finish grading done in area of absorption field will be done with light equipment.
7. No construction traffic to be allowed in area of absorption field.
8. All absorption field fingers to be placed at minimum depths to keep system in more permeable soils.
9. Septic tank specifications:
a. Reinforced concrete tanks
- Concrete :compressive strength > 4000 p.s.l. with wall thickness 2-1/2" or
- Concrete compressive strength > 4000 p.s.l. with wail thickness 4"
b. Tanks shall be certified by the State Board of Health & County Health Department.
C. Minimum septic tank capacity - 1250 gallons (not including volume of dosing tank)
d. All openings and Joints of the septic tank and dosing tank must be sealed watertight.
e. Tank shall be fitted with access riser (22' in dia. min.) and secured with gas tight cover.
10. Dosing System Specifications
a. Install a Simplex pump system meeting the pump requirements shown and capable of pumping
septic tank'.�effiuent. Pumps shall be Hyidromatic SP -33 series or equal.
(1) Pump capacity 35 gpm (min.)
WStatic head - 5 feet
Friction head - 5 feet
b. The dosing pump shall be mounted with lifting chem and break away flange.
C. The pumps shall be placed In a 1000 gallon dosing tank or equal that meets requirements under
Note 9.
d. An audio and visual high water alarm shall be installed in the basement.
e. Forcemain Inlet to distribution box shall be fitted with a 90' turn down elbow.
f. Forcemain shall be Schedule 40, 80 or 120 and meet ASTM D 1785 specifications.
EXISTING GRADE
i
z
HOLEY MOLEY"
SAYS:
4" PERFOR
PVC A.S.T.M. D-2728 ', v _ 1---800--382-5544
i CALL ?TOLL FREE
t,�,,,,,,L�,,,,,,1-800--428--5200
TYPICAL ABSORPTION LiNE X -SEC. FOR CALLS OUTSIDE OF INDIANA
N--T-S
No
8310
STATE OF
CONSULTING ENGINEERS -- LAND SURVEYORS
(317) 849--5935 1-800-728-6917 FAX: (317) 849--5942
INDIANAPOLIS INDIANA
CERTIFIED:
TLT
CK. BY
LMC
SCAM
111=300
DATE'
8/4/95 DATE MARK
CAUTION
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GROUND EVIDENCE. (including,
but not limited to, manholes, inlets, valves, &
marks made upon the ground by others.) AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILIMES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
REVISIONS
BY
L -I I jI ALARM
HYDRAULIC /
SEALINGFLANGE 2' CATE
VALVE ON
POWER
1407L CHECK VALVES ARE
OLL81 41 HOL IN 2'
k71p1RY
_cHSE
ALLOW DRAIN BACK
�
NOTE:
OFF
EFFLUENT PUMP
SHALL BE EQUAL TO
EFFLUENT
HHYDROOMATiC MODEL
PUMP iv
PUMP REQUIREMENTS
CAPACITY - 35 G - -
B.
B. HP . 4/10
IDN - 10 "
(SEE PUMP CURVE)
1000 GALLON DOSING TANK WITH
SEPTIC TANK EFFLUENT PUMP
N -T --S
EXISTING GRADE
�-TOPSOIL 40
CLEAN
GRAVEL
TYPICAL PERIMETER DRAIN X --SEC,
N-- T --S
BARRIER MATERIAL a' STRAW L EARTH FILL
OR SYNTHEIC FILTER FABRIC
1. Requirements for absorption system:
a. Trenches shall be constructed 3' wide maximum
b. A minimum 12' of washed gravel shall surround the distribution laterals, as shown.
c. Absorption field -A minimum of 800 LF. of distribution lateral.
d. 7.5' minimum spacing -center of lateral to center of lateral
2 Absorption field lateral specifications
a. Must be at least 4' In diameter & meet A.S.T.M. D-2729 or A.S.T. F810-83 specifications.
b. The pipe must have perforations with the equivalent total opening as a comparable the laid with
1/4 open Joints per foot of tile. with the following provisions:
I. Three rows of holes
11. 1/2' to, 1/4" diameter holes with
1/2M holes at 2-1/4« or closer spacing
5/8 holes at 3-1/2* or closer spacing
1/4- holes at 5" or closer spacing
III. Equal separation of rows around the circumference
c. The pipe must be delivered In straight (unrolled) lengths.
3. Gravity sewer must be P.V.C. SDR -35 and meet A.S.T.M.-D 3034 specifications for 4' pipe.
4. System as designed and shown is done with the intention of the system being Installed at minimum depths.
5. No clay fill material will be placed over absorption field. Natural ground line to remain as much as
possible.
6. Finish grading over- absorption field will be done to obtain positive surface drainage away from field. Any
finish grading done in area of absorption field will be done with light equipment.
7. No construction traffic to be allowed in area of absorption field.
8. All absorption field fingers to be placed at minimum depths to keep system in more permeable soils.
9. Septic tank specifications:
a. Reinforced concrete tanks
- Concrete :compressive strength > 4000 p.s.l. with wall thickness 2-1/2" or
- Concrete compressive strength > 4000 p.s.l. with wail thickness 4"
b. Tanks shall be certified by the State Board of Health & County Health Department.
C. Minimum septic tank capacity - 1250 gallons (not including volume of dosing tank)
d. All openings and Joints of the septic tank and dosing tank must be sealed watertight.
e. Tank shall be fitted with access riser (22' in dia. min.) and secured with gas tight cover.
10. Dosing System Specifications
a. Install a Simplex pump system meeting the pump requirements shown and capable of pumping
septic tank'.�effiuent. Pumps shall be Hyidromatic SP -33 series or equal.
(1) Pump capacity 35 gpm (min.)
WStatic head - 5 feet
Friction head - 5 feet
b. The dosing pump shall be mounted with lifting chem and break away flange.
C. The pumps shall be placed In a 1000 gallon dosing tank or equal that meets requirements under
Note 9.
d. An audio and visual high water alarm shall be installed in the basement.
e. Forcemain Inlet to distribution box shall be fitted with a 90' turn down elbow.
f. Forcemain shall be Schedule 40, 80 or 120 and meet ASTM D 1785 specifications.
EXISTING GRADE
i
z
HOLEY MOLEY"
SAYS:
4" PERFOR
PVC A.S.T.M. D-2728 ', v _ 1---800--382-5544
i CALL ?TOLL FREE
t,�,,,,,,L�,,,,,,1-800--428--5200
TYPICAL ABSORPTION LiNE X -SEC. FOR CALLS OUTSIDE OF INDIANA
N--T-S
No
8310
STATE OF
CONSULTING ENGINEERS -- LAND SURVEYORS
(317) 849--5935 1-800-728-6917 FAX: (317) 849--5942
INDIANAPOLIS INDIANA
CERTIFIED:
TLT
CK. BY
LMC
SCAM
111=300
DATE'
8/4/95 DATE MARK
CAUTION
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GROUND EVIDENCE. (including,
but not limited to, manholes, inlets, valves, &
marks made upon the ground by others.) AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILIMES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.