HomeMy WebLinkAboutA111WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
10'-8" 12'-0"
OFFICE
207 WORK
ROOM
204
ENTRY
201
OPEN OFFICE
210
CONF
203
CONF
202
OFFICE
211
OFFICE
208
OFFICE
206
OFFICE
215
OFFICE
214
OFFICE
213
OFFICE
212
OFFICE
205
IT/STG.
209
12'-63
4
"
10'-5"
10'-41
2
"
10'-5"
9'-83
4
"±
12'-1 1
4
"
3'-0"
10'-8"
8'-5"
CL
3'-63
4
"
8'-9"
9'-81
2
" 2'-3"
5'-5" 9'-0" 13'-0"
CLEAR
4'-101
2
4'-113 "
4
11'-6" "
(CLEAR)
10'-2"
135°
135°
FE
ARCHITECTURAL
FLOOR PLAN
A111
NOT TO SCALE
WALL AT MULLION DETAIL
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
DEMISING WALL TO DECK WITH INSULATION
35
8" METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" SOUND BATT INSULATION EACH
SIDE OF WALL ABOVE CEILING.
W1
WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W2
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
A111
1
DATE DESCRIPTION
ISSUE
02.09.18 REVIEW SET
02.13.18 PERMIT SET
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
PROJ. MGR DRAWN BY
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
FOUR QUADRANTS
11939 N. MERIDIAN ST.- 2ND FLOOR
CARMEL, IN 46032
AS KV
2017.272
2ND FLOOR
N
0 2' 4' 8' 16'
DEMOLITION PLAN
KEEP EXISTING CEILING GRID IF POSSIBLE. IF CEILING GRID IS NOT
CONTINUOUS WITH CORRIDOR, THEN NEW CEILING GRID TO
MATCH BUILDING STANDARD WILL BE REQUIRED IN THIS
LOCATION.
REMOVE EXISTING CEILING GRID AS SHOW PER NEW EXPOSED
CEILING AREAS. REFER TO A121 REFLECTED CEILING PLAN FOR
MORE INFORMATION.
DEMOLITION PLAN NOTES
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE, TRACK
LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
DEMOLITION LEGEND
AREA NOT IN CONTRACT
AREA OF WORK
DEMOLITION PLAN/
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
GENERAL NOTES
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINE FOR REFRIGERATOR. CONFIRM LOCATION
WITH TENANT.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x
3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
FIRE EXTINGUISHER TO BE PROVIDED BY TENANT AND INSTALLED
ACCORDING TO NFPA 10.
PROVIDE FINISHED DRYWALL AT EXTERIOR WALL TO DECK.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
PROVIDE 4'-0"W X 8'-0"H
3
8" THICK TEMPERED GLASS WINDOW IN
THIS LOCATION WITH TIMELY ALUMATONE FRAME. TOP OF FRAME
TO ALIGN WITH TOP OF DOOR FRAMES.
PROVIDE SEPARATE PRICE FOR ISLAND IN ENTRY 201.
PLAN NOTES
0 2' 4' 8' 16'
TYP.
A111
1
A211
5
A211
2
A211
3
W2
W2
W2 W2
W2
W2
W2
W2
W2
W2
W2
A211
4
W2
W2
W2
W2
W2
W2
03/12/18
Nick Mishler