Loading...
HomeMy WebLinkAboutA111WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL 10'-8" 12'-0" OFFICE 207 WORK ROOM 204 ENTRY 201 OPEN OFFICE 210 CONF 203 CONF 202 OFFICE 211 OFFICE 208 OFFICE 206 OFFICE 215 OFFICE 214 OFFICE 213 OFFICE 212 OFFICE 205 IT/STG. 209 12'-63 4 " 10'-5" 10'-41 2 " 10'-5" 9'-83 4 "± 12'-1 1 4 " 3'-0" 10'-8" 8'-5" CL 3'-63 4 " 8'-9" 9'-81 2 " 2'-3" 5'-5" 9'-0" 13'-0" CLEAR 4'-101 2 4'-113 " 4 11'-6" " (CLEAR) 10'-2" 135° 135° FE ARCHITECTURAL FLOOR PLAN A111 NOT TO SCALE WALL AT MULLION DETAIL AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL TO DECK WITH INSULATION 35 8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING. W1 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. A111 1 DATE DESCRIPTION ISSUE 02.09.18 REVIEW SET 02.13.18 PERMIT SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com FOUR QUADRANTS 11939 N. MERIDIAN ST.- 2ND FLOOR CARMEL, IN 46032 AS KV 2017.272 2ND FLOOR N 0 2' 4' 8' 16' DEMOLITION PLAN KEEP EXISTING CEILING GRID IF POSSIBLE. IF CEILING GRID IS NOT CONTINUOUS WITH CORRIDOR, THEN NEW CEILING GRID TO MATCH BUILDING STANDARD WILL BE REQUIRED IN THIS LOCATION. REMOVE EXISTING CEILING GRID AS SHOW PER NEW EXPOSED CEILING AREAS. REFER TO A121 REFLECTED CEILING PLAN FOR MORE INFORMATION. DEMOLITION PLAN NOTES ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME CEILING GRID AND TILES, 2'x4' SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT EXIT LIGHT DEMOLITION LEGEND AREA NOT IN CONTRACT AREA OF WORK DEMOLITION PLAN/ 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. GENERAL NOTES PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x 3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. FIRE EXTINGUISHER TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. PROVIDE FINISHED DRYWALL AT EXTERIOR WALL TO DECK. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. PROVIDE 4'-0"W X 8'-0"H 3 8" THICK TEMPERED GLASS WINDOW IN THIS LOCATION WITH TIMELY ALUMATONE FRAME. TOP OF FRAME TO ALIGN WITH TOP OF DOOR FRAMES. PROVIDE SEPARATE PRICE FOR ISLAND IN ENTRY 201. PLAN NOTES 0 2' 4' 8' 16' TYP. A111 1 A211 5 A211 2 A211 3 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 A211 4 W2 W2 W2 W2 W2 W2 03/12/18 Nick Mishler