HomeMy WebLinkAboutA121OFFICE 207 WORK ROOM 204 ENTRY 201 REFRIG BY TENANT OPEN OFFICE 210 LF LF CONF 203 MICRO CONF 202 OFFICE 211 OFFICE 208 OFFICE 206 OFFICE 215 OFFICE 214 OFFICE 213 OFFICE 212 OFFICE 205 IT/STG. 209 J J J +42" GFCI +44" +44" DED +44" DED +42" GFCI TV +60" +60" +60" +60" TV J +24" GFCI GFCI +44" +44" N3 S S N SN S N SN S N SN N3 S S N EQ. EQ. 8'-0" EQ. EQ. EQ. 16'-0" 5'-6" 16'-0" EQ. SN SN SN S N S N S N S N 5'-0" EQ. 4'-0" EQ. EQ. EQ. EQ. 5'-0" 4'-0" 5'-6" CL C L EQ. CL NLEL NLEL NLEL REFLECTED CEILING PLAN A121 EXIT LIGHT FIXTURE LIGHT FIXTURE, 2'x4', LED, BUILDING STANDARD EXISTING/RELOCATED DIFFUSER, LAY-IN, 4"x4' EXISTING/RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x4' INDICATES NIGHT LIGHT LOCATION NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. NEW OR RELOCATED EXISTING TO REMAIN INDICATES NIGHT LIGHT LOCATION EXIT LIGHT FIXTURE CEILING GRID, SUSPENDED, 2'x4' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x4', LED, INDIRECT CEILING LEGEND REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 02.09.18 REVIEW SET 02.13.18 PERMIT SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER PROJ. MGR DRAWN BY 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com FOUR QUADRANTS 11939 N. MERIDIAN ST.- 2ND FLOOR CARMEL, IN 46032 AS KV 2017.272 2ND FLOOR N 0 2' 4' 8' 16' EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND A121 ELECTRICAL PLAN/ 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION GENERAL RCP NOTES RCP PLAN NOTES MECHANICAL NOTES EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GENERAL ELEC. NOTES PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24" A.F.F. PROVIDE POWER AND DATA AT 60" A.F.F. FOR TENANT'S WALL MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH TENANT. CONFIRM WITH TENANT ON ELECTRICAL REQUIREMENTS NEEDED IN THIS LOCATION. 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. INSTALL FLOATING CLOUD WITH ATROMSTRONG AXIOM 4" TRIM AROUND PERIMETER AT 9'-6"AFF WITH BUILDING STANDARD CEILING GRID AND TILE. FLOAT CLOUD WITH ALL-THREAD INSTALLED 15" FROM EDGES. PAINT ALL THREAD SAME COLOR AS CEILING DECK. INSTALL MINIMAL QUANTITY OF ALL-THREAD SUPPORTS AS POSSIBLE. DESIGN INTENT IS TO MAKE ALL -THREAD SUPPORTS AS VISUALLY UNOBTRUSIVE AS POSSIBLE. LOCATE FLEX DUCT TO NEW DIFFUSERS SUCH THAT THEY ARE NOT VISIBLE FROM GROUND LEVEL. NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CLOUD. FIRE SPRINKLER CONTRACTOR TO PROVIDE SUBMITTAL OF FINAL LAY-OUT FOR FINAL APPROVAL PRIOR TO INSTALLATION. PROVIDE DRYWALL BULKHEAD AT THIS LOCATION, BOTTOM TO BE 7'-1" AFF. FACE OF BULKHEAD TO EXTEND TO DECK AND TO BE PAINTED SAME AS ADJACENT WALL. ALIGN EDGE OF BULKHEAD WITH ADJACENT WALL AS SHOWN ON THE PLAN. HORIZONTAL PLANE OF BULKHEAD TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. REMOVE AS MUCH OF THE EXPOSED CONDUIT, PIPING, JUNCTION BOXES AND MISCELLANEOUS UNUSED EQUIPMENT AS POSSIBLE. REPAIR THE EXISTING DUCT INSULATION WRAP SUCH THAT NO TORN OR DAMAGED INSULATION IS VISIBLE (IF APPLICABLE.) CLEAN AND PREPARE FOR DRYFALL PAINT "PT4." AS SPECIFIED, PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. REMOVE LOW PRESSURE SUPPLY BRANCH LINE DUCT AND REPLACE WITH NEW RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS. REFERENCE SHEET A131 FOR FURTHER DETAIL. IF NEW GRID IS REQUIRED IN THIS AREA, PROVIDE BUILDING STANDARD CEILING GRID AND TILE TO MATCH EXISTING CORRIDOR. DESIGN INTENT IS TO BE SEAMLESS. LIGHT SWITCH, 3-WAY LIGHT SWITCH LIGHT SWITCH, 3-WAY LIGHT SWITCH SWITCH, GARBAGE DISPOSAL SWITCH, GARBAGE DISPOSAL 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. J J +42" 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2'x4' AT 8'-8" A.F.F. TILES TO BE 2'x4' ARMSTRONG SECOND LOOK CORTEGA II. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 6. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. LIGHT FIXTURE, 8' LED LINEAR SUSPENDED, BUILDING STANDARD (BOTTOM OF FIXTURED MOUNTED AT 9'-0" AFF OPEN TO DECK CEILING (REFER TO R04) 03/12/18 Nick Mishler