HomeMy WebLinkAbout04060167 Building PlansStores,, CLAY TERRACE Inc. 146th STREET AND US 31 CARMEL, INDIANA 46032 BID SET ISSUED: MAY 28, 2004 a DOORNO. X -X FIXTUREMURNISHINGS NO. X -X MATERIAL FINISH DRAWING SYMBOLS X. ELEVATION KEY WALL OR DETAIL SECTION NO. FIRE PROT./SPRINKLER SYSTEMS NOTES I. LANDLORD WILL STUB TO TENANTS SPACE. TENANT IS RESPONSIBLE FOR INSTALLING A SPRINKLER SYSTEM. 2. THIS STORE REQUIRES A NEW SPRINKLER SYSTEM. ALL SPRINKLER HEADS SWALL BE QUICK RESPONSE TYPE. ALL SPRINKLER HEADS At THE STOREFRONT SHALL BE CONCEALED WITH MATCHING COvERPLATES. ALL OTHER SPRINKLER HEADS THROI,IGHOUT THE SALES AREA SHALL BE FULLY RECESSED WITH MATC14MG COVERPLATES. 3. PROVIDE CONCEALED TYPE SPRINKLER HEADS IN THE RETAIL AREAS. PROVIDE EXPOSED TYPE HEADS N NON -RETAIL CEILINGS/EXPOSED S RE AREAS. 4. UPON COMPLETION OF ALL SPRINKLER S STEM MODIFICATIONS AND TESTS, THE G.C. SHALL SUBMIT A WRITTEN HAS BEENEIN$PECTEDTo THE LANDLORD AND AND APPROVED. 1IERIFY�WITHTLOCAL REGULATIONS. SPRINKLER SYSTEM 5. FIRE PROTECTION CONTRACTOR SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL FIRE PROTECTION REQUIREMENTS INCLUDING J�UT NOT LIMITED TO NFPA %. VERIFY WITH LOCAL RE6-ALATIONS. 16. TENANT'S SPRINKLER SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NWA 13 AND SHALL BE WITNESSED BY THE LOCAL FIRE MARSHAL AND LANDLORD'S REPRESENTATIVE VERIFY WITH LOCAL REGULATICN$. 1. TENANT'S GAG. SHALL COORDINATE THE TIONS OF FIRE SPRINKLER HEADS WITH THE LIGHTING LVER�ATIONISPRINKLER PRIOR TOINSTALLA ION. VERIFY WITS SHALL BE GENTEIRED H LOCAL REGULATTWEEN OR IONS. THE WITH LIGHT FIXTURES. 8. THE SPRINKLER SUBCONTRACTOR $WALL MODIFY THE EXISTING DESIGN AND PROVIDE AN APPROVED 'CALCULATED' SPRINKLER SYSTEM LAYOUT t0 THE ARCHITECT THAT CONFORM TO NEW DESIGN. THE DESIGN LAYOUT PROVIDED HEREIN REFI! ECT$ THE VISUAL LAYOUT DESIRED. REVISIONS MUST BE SENSITIVE TO THE OVERALL VISUAL IMPACT. DRAWINGS AND CALCULATIONS FOR SUCH[ SYSTEMS SHALL BE SUBMITTED TO THE OWNER'S INSURANCE AGENCY (PRIOR TO FABRICATION OF ANY MATERIAL) FOR REVIEW AND APPROVAL PRIOR TO SUBMISSION OF THE CODE REVIEW AUTHORITY. DRAWINGS AND CALCULATIONS MUST ALSO BE SIGNED AND SEALED BY AN ENGINEER LICENSED N THESTATE WHERE THE SUBJECT BUILDING IS LOCATED. ALL COST FOR REVIEW, PERMIT, 66NNG AND SEALING OF DRAWINGS AND CALCULATION SHALL BE BOR�N�E_py THE SPRINKLER SUBCONTRACTOR g. THE T.G.C. SHALL INCLUDE, N HIS PROPOSAL, A SEPARATES AS � [RED FOR PROTECTION OFTTNG HE EXISTING AUTOMATIC FIRE PROTECTION SPRINKLER LEASE SPACE. N THE EVENT THE LANDLORD HAD THIS WORK EXECUTED BY HIS SPRINKLER CONTRACTOR, THE GENERAL CONTRACTOR SHALL P URNISH CLAIRE'S THE BID ITEM AS A DEDUCT IN HIS CONTRACT PRICE FOR CLAIRE'S TO REIMBURSE THE LANDLORD FOR SAID WORK. CONTACTS I CLAIRE'S STORES, INC. 3 8i1.129th AVENUE SUITE 202 PEMBROKE PINES, FLORIDA 33021 CONTACT: CARLOS RODRIGUEZ PHONE: (954) 433-3435 FAX: (954) 433-1488 LANDLORD: SIMON PROPERTIES 115 WEST WASHINGTON ST INDIANAPOLIS, INDIANA 46204 CONTACT: JANE MILLER PHONE: (311) 263-1645 FAX: (311) 685-1269 GENERAL TO BE BID CONTR: BUILDING CARMEL/CLAY BUILDING DEP DEPARTMENT: ONE CIVIC SQUARE CARMEL, INDIANA 46031 FIRE CARMEL FIRE DEPARTMENT DEPARTMENT: 3 CIVIC SQUARE CARMEL, INDIANA 46032 PHONE NUMBER: (311) 511-2631 PERMIT STATE PERMITS EXPEDITOR: 1238 FOLEY ROAD RACNE, WISCONSON 53402 CONTACT: VAIN PODLIGAR PHONE NUMBER: (262)152-9900 FAX NUMBER (262)152-9136 RESPONSIBILITIES EXISTING DOOR 00-- NEW DOOR OA COLOR GEL SLEEVES • • DE$ICsNATION FIRE PROT./SPRINKLER SYSTEMS NOTES I. LANDLORD WILL STUB TO TENANTS SPACE. TENANT IS RESPONSIBLE FOR INSTALLING A SPRINKLER SYSTEM. 2. THIS STORE REQUIRES A NEW SPRINKLER SYSTEM. ALL SPRINKLER HEADS SWALL BE QUICK RESPONSE TYPE. ALL SPRINKLER HEADS At THE STOREFRONT SHALL BE CONCEALED WITH MATCHING COvERPLATES. ALL OTHER SPRINKLER HEADS THROI,IGHOUT THE SALES AREA SHALL BE FULLY RECESSED WITH MATC14MG COVERPLATES. 3. PROVIDE CONCEALED TYPE SPRINKLER HEADS IN THE RETAIL AREAS. PROVIDE EXPOSED TYPE HEADS N NON -RETAIL CEILINGS/EXPOSED S RE AREAS. 4. UPON COMPLETION OF ALL SPRINKLER S STEM MODIFICATIONS AND TESTS, THE G.C. SHALL SUBMIT A WRITTEN HAS BEENEIN$PECTEDTo THE LANDLORD AND AND APPROVED. 1IERIFY�WITHTLOCAL REGULATIONS. SPRINKLER SYSTEM 5. FIRE PROTECTION CONTRACTOR SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL FIRE PROTECTION REQUIREMENTS INCLUDING J�UT NOT LIMITED TO NFPA %. VERIFY WITH LOCAL RE6-ALATIONS. 16. TENANT'S SPRINKLER SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NWA 13 AND SHALL BE WITNESSED BY THE LOCAL FIRE MARSHAL AND LANDLORD'S REPRESENTATIVE VERIFY WITH LOCAL REGULATICN$. 1. TENANT'S GAG. SHALL COORDINATE THE TIONS OF FIRE SPRINKLER HEADS WITH THE LIGHTING LVER�ATIONISPRINKLER PRIOR TOINSTALLA ION. VERIFY WITS SHALL BE GENTEIRED H LOCAL REGULATTWEEN OR IONS. THE WITH LIGHT FIXTURES. 8. THE SPRINKLER SUBCONTRACTOR $WALL MODIFY THE EXISTING DESIGN AND PROVIDE AN APPROVED 'CALCULATED' SPRINKLER SYSTEM LAYOUT t0 THE ARCHITECT THAT CONFORM TO NEW DESIGN. THE DESIGN LAYOUT PROVIDED HEREIN REFI! ECT$ THE VISUAL LAYOUT DESIRED. REVISIONS MUST BE SENSITIVE TO THE OVERALL VISUAL IMPACT. DRAWINGS AND CALCULATIONS FOR SUCH[ SYSTEMS SHALL BE SUBMITTED TO THE OWNER'S INSURANCE AGENCY (PRIOR TO FABRICATION OF ANY MATERIAL) FOR REVIEW AND APPROVAL PRIOR TO SUBMISSION OF THE CODE REVIEW AUTHORITY. DRAWINGS AND CALCULATIONS MUST ALSO BE SIGNED AND SEALED BY AN ENGINEER LICENSED N THESTATE WHERE THE SUBJECT BUILDING IS LOCATED. ALL COST FOR REVIEW, PERMIT, 66NNG AND SEALING OF DRAWINGS AND CALCULATION SHALL BE BOR�N�E_py THE SPRINKLER SUBCONTRACTOR g. THE T.G.C. SHALL INCLUDE, N HIS PROPOSAL, A SEPARATES AS � [RED FOR PROTECTION OFTTNG HE EXISTING AUTOMATIC FIRE PROTECTION SPRINKLER LEASE SPACE. N THE EVENT THE LANDLORD HAD THIS WORK EXECUTED BY HIS SPRINKLER CONTRACTOR, THE GENERAL CONTRACTOR SHALL P URNISH CLAIRE'S THE BID ITEM AS A DEDUCT IN HIS CONTRACT PRICE FOR CLAIRE'S TO REIMBURSE THE LANDLORD FOR SAID WORK. CONTACTS I CLAIRE'S STORES, INC. 3 8i1.129th AVENUE SUITE 202 PEMBROKE PINES, FLORIDA 33021 CONTACT: CARLOS RODRIGUEZ PHONE: (954) 433-3435 FAX: (954) 433-1488 LANDLORD: SIMON PROPERTIES 115 WEST WASHINGTON ST INDIANAPOLIS, INDIANA 46204 CONTACT: JANE MILLER PHONE: (311) 263-1645 FAX: (311) 685-1269 GENERAL TO BE BID CONTR: BUILDING CARMEL/CLAY BUILDING DEP DEPARTMENT: ONE CIVIC SQUARE CARMEL, INDIANA 46031 FIRE CARMEL FIRE DEPARTMENT DEPARTMENT: 3 CIVIC SQUARE CARMEL, INDIANA 46032 PHONE NUMBER: (311) 511-2631 PERMIT STATE PERMITS EXPEDITOR: 1238 FOLEY ROAD RACNE, WISCONSON 53402 CONTACT: VAIN PODLIGAR PHONE NUMBER: (262)152-9900 FAX NUMBER (262)152-9136 RESPONSIBILITIES _ 00-- • - - WOOD BASE - PAINTED • • • • _ VINYL BASE • • • - GWB CEILING AND FRAMING SYSTEM • • • m SUSPENDED ACOUSTICAL CEILINGS AND GRIDS 2002 INDIANA ELECTRIC CODE (NFPA 10-2002) • • 2003 INDIANA FIRE CODE (2000 IFC) SCHEDULE ` ' 2. ' • > G.G. TO COORDINATE WITH OWNER SUPPLIER MATCH EXISTING MALL FLOORING AS REQR'D. "DED • INST. • • (1) TYPE ABC PER PLAN VINYL COMPOSITION TILE SEISMIC SECTIONS AND DETAILS • • _ TRANSITION STRIP / TO ENTRY TILE • • INSTALLED [NST. • ------ DIVISION 01000 - GENERA- REQUIREMENTS • • PERMITS, FEES, AND INSURANCE • --.._ -. PROFESSIONAL CLEANING • CORNER GUARDS TEMPORARY POWER / WATER • • ---- CERTIFICATE OF OCCUPANCY • _ DUMPSTER / TRASH REMOVAL • • COORDINATE REQUIREMENTS w/ LANDLORD • GC. TO COORDINATE WITH TRIM RAIL SUPPLIER DIVISION 02000 _ SITE WOFr, • DEMOLITION DIVISION 010000 - BPECIALTIEB SHORING AND BRACING • • _. TEMPORARY BARRICADES • • COORDNATE REQUIREMENT8 w/ LANDLORD ASBESTOS TE5TNG AND ABATEMENT • DIVISION 03000 - CONCRETE PATCHING - CCNCRETE SLAB • - CAST -IN-PLACE CONCRETE • • --- CONCRETE TOPPING / LEVELING COMPOUND • • FLOOR CUTTING AND/OR CORE DRILLING • • - DIVISION 04000 MASONRY - NO WORK REQUIRED IN THIS SECTION _ - DIVISION 05000 M15C. METALS ---- - PAINTED METAL PANELS / CLADDING STRIPS -.------ ALUMINUM REVEALS --- -- COLD ROLLED CHANNELS • • - LIGHT GAUGE FRAMING • • --- DIVISION 06000 -WOOD AND PLASTICS - _-_-- BLOCKING (MISC) • • _. FIRE RETARDANT LUMBER / PLYWOOD • • __.._-. COLORED GELS COVERS FOR FLOURESCENT TUBE LAMPS • • - DIVISION 07000 - THERMAL AND MOISTURE PROTECTION -_ INSULATION (DUCTWOW-) • • (SEE MECHANICAL PLANS) ROOF PENETRATION, CURBING AND FLASHING • • COORDINATE WITH LANDLORD_ SEALANT AND CAULKING • • - FIRE STOPPING • • ---- WATERPROOF MEMBRANE AT TOILET ROOM • • COORDINATE REQUIREMENTS w/ LANDLORD DIVISION 08000 - DOORS AND WINDOWS RATED METAL DOORS AND HAI;�UWARE • • REAR SERVICE DOOR • ___--. ALL HARDWARE FOR DOORS • • EXCEPT P44EL PANIC (F.O1Cd METAL GLAZING FRAMES (AT STOREFRONT) • • __- LAMINATED / TE-MPEIZED GLAZING (AT STOREFRONT) • _-- ROLLING SECURITY GRILLE DIVISION 09000 - FINISHES GYPSUM WALLBOARD (ON STOREFRONT SOFFITS /OUTER FFF�� FINISH TAPED, SPACKLED AND SANDED SMOOTH TO A 4-5 LEVEL FASCIA SURFACES TO RECEIVE FRESCO FINISH) FINISHED AND WHITE PRIMER PAINTED TWO COATS, ALL BY TGC. EXTERIOR ( STUCCO ) FINISH AND MATERIAL 5UBTRATE _ 00-- • - - WOOD BASE - PAINTED • • • • _ VINYL BASE • • • - GWB CEILING AND FRAMING SYSTEM • • • -_ SUSPENDED ACOUSTICAL CEILINGS AND GRIDS 2002 INDIANA ELECTRIC CODE (NFPA 10-2002) • • 2003 INDIANA FIRE CODE (2000 IFC) PAINTS • • • • 2. ENTRY TILE FLOORING AND BABE • • G.G. TO COORDINATE WITH OWNER SUPPLIER MATCH EXISTING MALL FLOORING AS REQR'D. • • • (1) TYPE ABC PER PLAN VINYL COMPOSITION TILE SEISMIC SECTIONS AND DETAILS • • _ TRANSITION STRIP / TO ENTRY TILE • • G.G. TO COORDINATE WITH OWNER INSTALLER CARPET REDUCER STRIP / TO V.C.T. • • TCL. TO UNGRATE, ASSEMBLE AND PAINT TRANSITION MATERIAL / TO MALL FLOORING • • - CORNER GUARDS • • • • G.G. TO COORDINATE WITH OILNER INSTALLER CARPET • • SLATWALL PANELS, TRIM 4 INSERTS • • GC. TO COORDINATE WITH TRIM RAIL SUPPLIER DIVISION 010000 - BPECIALTIEB _ STOREFRONT 86NAGE • • INSTALLED BY SIGN VENDOR, SEE NOTE NO. 2 EXTERIOR CANOPY AND FRAME • HANDICAPPED ACCE55I5ILITY 5I6 A6E 90 •FIRE -- FIFE EXTINGUISHERS • • �- TOILET ROOM ACCES50R21E5 _ 00-- MIRRORS / GRAB BARS / PAPER TOWEL / TOILET PAPER, ETC. INTERIOR WALL -MOUNTED NON -ILLUMINATED SIGNAGE • • SECURITY CAMERA _ APPLIED STOREFRONT GLASS LOGO • • • • GC TO PROVIDE BLO_:.KING FO MOUNTING NON -ILLUMINATED 51CxNAGE • • REF. DRAWINGS DIVISION 011000 - EQUIPMENT 2002 INDIANA ELECTRIC CODE (NFPA 10-2002) FIRE PREVENTION: 2003 INDIANA FIRE CODE (2000 IFC) COMPUTER • • FULLY SPRINKLERED PER CODE 2. POINT OF SALE (POS) EQUIPMENT • • 3. FIRE EXTINGU181-QRS: AUDIO SYSTEM/ SPEAKERS /RECEIVER AND WIRES • • (1) TYPE ABC PER PLAN DIVISION 012000 -FURNISHING SEISMIC SECTIONS AND DETAILS N _ SALES AREA FIXTURES /PANELS • • TLsL. TO UNCRATE AND ASSEMBLE/ SEE SHEET FI SALES AREA CEILING SUSP. DECORATIVE RESIN DISKS • • TCL. TO UNGRATE, ASSEMBLE AND PAINT CASHWRAP/L.AR 3E FLOOR FIXTURES • • I- CORNER GUARDS LLJ V • • STOCKROOM SHELVES • • E LOCKERS • • SEE NOTES ON FI / GC TO PROVIDE BLOCKING FOR MOUNTING METAL EMPLYOE _ 5EC1JRITY MIRRORS • • -- SECURITY MIRROR CEILNG SPLINES AND WALL CHATWEL5 • • -- SECURITY CAMERA • • -- SECURITY DOME • • -- ACCESSIBILITY: • • GC TO PROVIDE BLO_:.KING FO MOUNTING LADDER HOOKS 2003 INDIANA MECHANICAL CODE (2000 IMC) GENERAL NOTES L ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. 2. GRILLE CONTRACTOR, SIGN CONTRACTOR AND CARPET AND CERAMIC TILE FLOORING CONTRACTOR ARE CONTRACTED DIRECTLY WITH CLAIRE'S STORES, INC. THE TENANT'S GENERAL CONTRACTOR SHALL COORDINATE ALL INSTALLATION WITH THESE CONTRACTORS. 3. STOREFRONT SIGN INSTALLATION SHALL BE BY TENANT'$ SIGNAGE VENDOR AND COORDINATED WITH OTHER TRADES BY TENANT'S GSC. INTERIOR SIGNAGE SHALL BE PROVIDED BY TENANT AND INSTALLED BY TIG.IC. 4. EINE CY EXIT ILLUMINATION SHALL 13E PROVIDED AS SHOWN ON ELEC. DRAWMS. ADDITIONAL EINE Y EXIT ILLUMINATION MAY BE NEEDED SUBJECT TO AN ON-SITE INSPECTION. 5. THE t . IS RESPONSIBLE FOR PROVIDING A SMOOTH LEVEL FLOOR SURFACE THAT MEETS THE MANUS CURERS INSTALLATION SPECIFICATIONS PRIOR TO THE INSTATION OF ALL FLOORING MATERIALS. USE XY BASED LEVELING COMPOUND. PATCH/SHIM ALL AREAS AS NECESSARY SO THAT NEW FLOORING MEETS EYEL WITH ALL OTHER FLOORING SURFACES, MAXIMUM TOLERANCE OF 1/8' PER FOOT. 6. THE FLOORING SUB -CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THE CONDITION OF THE BASE OF THE FLOOR MEETS THE INSTALLATION SPECIFICATIONS PROIR TO THE INSTALLATION OF THE NEW FLOORING MATERIAL. 1. TjG.C. SHALL FIELD VERIFY EXISTING STRUCTURE HEIGHT, CENTERLINE, LOCATIONS, AND ANY OTHER COND111ION8 WHICH MIGHT AFFECT THE CONSTRUCTION PRIOR TO BIDDING THE JOB. 8. MESONS BIDDING ON THIS PROJECT SHALL DIRECT ALL QUESTIONS REGARDING BIDDING, IDENTITY OF GENERAL CONTRACTOR/SUB-CONTRACTOR, OR CONTRACT RELATED ISSUES TO CLAIRE'S STORES, INC, E CONTACT INFORMATION ON THIS SHEET. 3 ALL AND EQUIPMENT SHOWN IS NEW CONSTRUCTION BY TENANTS GL, UNLESS NOTED OTHERWISE. 10. 1EN8 GENERAL CONTRACTOR SHALL VERIFY THAT ALL ROOF LEAKS ABOVE THE LEASE SPACE HAVE REPAIRED BY THE LANDLORD'S ROOFING CONTRACTOR PRIOR TO BEGINNING ANY NEW CON TION WORK 11. SEE MECHANICAL PLAN ON DWG. MI FOR NOTES AND RELATED INFORMATION ABOUT THE SMOKE EVACUATION SYSTEM. T.Gc. TO PROVIDE AND INSTALL, IF REQUIRED. 12. SEE pOWER PLAN ON DW -s. EI FOR NOTES AND RELATED INFORMATION ABOUT THE FIRE ALARM/LIFE SAFTEY SYSTEM AND THE ENERGY MANAGEMENT SYSTEM. TLs.C. TO PROVIDE AND INSTALL, IF REQUIRED. 13. METAL'' TRANSITION STRIPS MUST BE INSTALLED BEFORE THE LAST ROW OF TILE IS SET. CANT IS INSTALLED LAST. THE V.C.T. AND IT'S TRANSITION STRIP MUST ALSO BE INSTALLED BEFORE THE cAwET. FLAME SPREAD RATINGS FLAMESPREAD: CEILING - (C-1) ONE HOUR RATED LAY -IN TILES GRID SYSTEM, AND HOLD-DOWN CLIPS STOREFRONT METAL - ( MT -I) ARMSTRONG MINITONE WET FORMED MINERAL ( MT -2) FIBER AND ARMSTRONG PRELUDE TEE NON-FLAMABRLE CMT -3) SURFACE BU41NIG CL A ASTM E [1122'14 FLAME SPREAD 25 OR UNDER UL LABELED CERAMIC TILE FLOORING - ( FC -2) UL CEILING ASSEMBLY DESIGN NO. P206 - NON-FLbMABLE SEE NOTE ON SHT. E 1 VINYL Q)MP. TILE FLOORING - ( FC -4) PAINT - ( PT -I, PT-2SHE) ARMSTR7NG, CLASSIC WHITE 0519 F 11 VINYL FLAME SPREAD RATE E 84-19 a E1JIN1 WILLIAMS COMPOSITION TILE FLOORING LA ASTM OO CONTRIBUTION 5 F 1066 COMP. 1, CLASS 2 SM CRITICAL RADIANT HEAT ASTM E 648 � DENSITY 0 NOTE= COMMERCIAL CARPET - ( FC -1) ALL DECORATIVE MATERIALS IN THE SALES ATLAS CARPET MILLS, INC. AREA MUST BE NON-COMBUSTIBLE OR FIRE FLAJ MA51LITY: CLASS I - EXCEEDS 96 RETARDANT TREATED. WATTS PER CM SMOKE DENSITY: NBS SMOKE DENSITY CHAMBER (NIST) LESS THAN 322 - ASTM E Fh62 w CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square I" Floor, Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT As the authorized agent responsible for obtaining a permit or permits', I certify that these plans are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building Services. I also understand that if it is determined that these plans are not identical, a STOP WORK will be served, as required under the Ordinances refe need below. ut onze ' nature Panted Name rle Iquired under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section I 31.1 entitled "Violations and Penalties". f ©L/ S: Permits /Forms/AuthentStickerll-01 KEY PLAN DIVISION 013000 SPECIAL CONSTRLICTICN . NO WOf2K REQUIRED WDER TH16 9ECTICN DIVISION 014000 CGNvETING sYsrErts - No tUORK R`aUlti� UNDER THIS SECTIort - - CLAY TERR�4CE RELEASED FOR CO �RUt DIVISION 015000 - MECHAwcAL AND PLUMBING w 146th 4 US 31 Subject tt) compliance with all R>>?;, of Sand COLD WATER SUPPLY • CO DEPT OF SEE MECHANICAL PLAN CA!"L, INDIANA 46032 O IT MIUIUNPJiTY SE DAMPERS • SEE MECHANICAL PLAN -- CITY OF CARMEL / CLAY DIFFUSER / GRILLES • • MD" �. H.vAC. HEATING AND COOLNG UNITS • • SEE MECHANICAL PLAN" • • - CIRCUIT H.V.A.C. DUCTWORK PLUMBING FIXTURES AND WATER HEATER • •RK - [)SI I I CITY I TOILET ROOM EXHAUST DUCTWO• • W ROOF PENETRATIONS • • COORDINATE WITH LANDLORD SANITARY LINE • • SMOKE DETECTORS • • COORDINATE WITH LANDLORD AND LOCAL B.D. SPRINKLERS • COORDINATE W/LL. AND LOCAL BD. / MODIFY A8 REQUIRED PROJECT DESCRIPTION INTERIOR TENANT FINISHES TO AN EXISTING BUILDING ( FIRST FLOOR ) FOR RETAIL TENANT SPACE. OCCUPANT LOAD CALCULATIONS: A. OCCUPANCY GROUP: PROJECT INFORMATION NOS: ALL WORK SHALL CONFORM TO ALL APPLICABLE GOVERNING CODES, B. CONSTRUCTION TYPE: INCLUDING, BUT NOT LIMITED TO, THE LATEST EDITIONS OF THE I. EXISTING BUILDING= FOLLOWING: BUILDING CODE AND 2003 INDIANA BUILDING CODE (2000 IBC) ACCESSIBILITY: INDIANA ACCESSIBILITY CODE 11992 CABG/ANSI AIM) MECHANICAL CODE: 2003 INDIANA MECHANICAL CODE (2000 IMC) PLUMBING CODE= 1999 INDIANA PLUMBING CODE (1991 UPC) ELECTRICAL CODE: 2002 INDIANA ELECTRIC CODE (NFPA 10-2002) FIRE PREVENTION: 2003 INDIANA FIRE CODE (2000 IFC) ENEWsY CODE: [DIANA ENERGY CONSERVATION CODE (1992 CABO) OCCUPANT LOAD CALCULATIONS: A. OCCUPANCY GROUP: NUMBER OF EXITS 1. EXISTING BUILDING: GROUP M, MERCANTILE B. CONSTRUCTION TYPE: TYPE II -B I. EXISTING BUILDING= EXIT DOOR WIDTH REQUIRED: FIRE RESISTIVE CONSTRUCTION RATINGS ALL WALLS : 0 HOUR FLOORS : 0 HOUR FLOOR/CEILING = 0 HOUR ROOF/CEILING : 0 HOUR FIRE CORRIDOR WALLS: 0 HOUR C. EXITING: 1. ALLOWABLE SQUARE FEET PER OCCUPANT A. MERCANTILE 30 S.F. / PERSON B. STORAGE 300 SF. / PERSON 2. OCCUPANT LOAD: GR055 LEASE AREA: 1406 SQUARE FEET NET SALES AREA: 1065 SQUARE FEET T 30 36 PERSONS NON -SALES AREA: 238 SQUARE FEET _ 300 1 PERSONS TOTAL OCCUPANT LOAD z 31 PERSONS 3. NUMBER OF EXITS T TITLE PAGE REQUIRED PER FLOOR 1 4. EXIT DOOR WIDTH REQUIRED: 36' 5. DISTANCE TO EXITS: 15' MAXIMUM 6. HARDWARE TYPE: HANDICAPPED PANIC HARDWARE D. FIRE EXTINGUISHER SYSTEMS _ 1. AUTOMATIC FIRE EXTINGUISHING A3.1 SYSTEM: FULLY SPRINKLERED PER CODE 2. SPRINKLER HEADS: RECESSED PENDANT AT CEILINGS 3. FIRE EXTINGU181-QRS: WITH COVERS (Wi) A4.1 DETAILS, DOOR SCHEDULE (1) TYPE ABC PER PLAN INDEX OF DRAWINGS TELEPHONE CONDUIT FOR SECURITY SYSTEM T TITLE PAGE D1 NOT USED - Al CONSTRUCTION PLAN, RCP, NOTES • • A2 STOREFRONT ELEVATION, MATERIALS SCHEDULE J A2.1 INTERIOR ELEVATIONS, DETAILS _ A3 STOREFRONT SECTIONS A3.1 STOREFRONT AND AWNING DETAILS = U A3.2 NOT USED i Q A4 WALL SECTIONS, DETAILS Q z A4.1 DETAILS, DOOR SCHEDULE T6.C. TO VERIFY IF IT I'S REOUIRED BY LANDLORD OR LOCAL B.D. A4.2 SEISMIC SECTIONS AND DETAILS N F1 FIXTURE/FURNISHINGS PLAN, SCHEDULE, NOTES �zo SP1 SPECIFICATIONS o�Dj Zcr_ SP2 SPECIFICATIONS SUPPLY, VENT, WASTE PIPfNG • M 1 WATER METER SYSTEM • • • T6.C. TO VERIFY IF IT IS REQUIRED BY LANDLORD OR LOCAL B.D.� �C SMOKE EVAGUATIGtJ '� El DIVISION 016000 - ELECTRICAL � w E2 SALES AREA LIGHT FIXTURES • • _ NON-SAL_S AREA FLUORESCENT LIGHTING • • - LAVATORY EXHAUST • • -_ EXIT AND EMERGENCY LIGHTING • • - ELECTRICAL OUTLETS • • TELEPHONE PANEL • • G.C. TO COORDINATE W/ TELEPHONE CO. TELEPHONE OUTLETS • • G.G. TO COORDINATE Wi TELEPHONE GO. WILD PER NOTE 9 ON EI -� CLAIRE'S ACCESSORIES CONDUIT FOR TELEPHONE WIRE5 /PULL STRING • OATS SPACE NO. A21 D I CK6 • • LEVEL I OF 1 EQUIFh1ENT MALL PLAN NO SCALE Ul MECHANICAL, PLUMBING PLANS POWER PLAN, NOTES, SCHEDULES LIGHTING PLAN, LEGEND, NOTES, SCHEDULES GROSS LEASE AREA GROSS SALES AREA NET SALES AREA NON -SALES AREA STORE DESIGN TYPE AREA CALCULATIONS Q ��11N111lH�1 Z 0 A) 'o U 0 �> cp Ill CA N 0 ' N ^ 1 V ttl _ a Z " .0 LU Ws u' s . C, An t P U =^ cn w 1-- v 64 ' 4 ^ C14 U_ Q (L -N 4 M U) LU TELEPHONE CONDUIT FOR SECURITY SYSTEM • _ CONDUITS FOR STEREO SYSTEM • • - TIIIECLOCK • • _ PER NOTE 15 ON EI IF5 PANEL (ELECTRICAL PANEL) • • SEE ELECTRICAL ORAWNGS UI ELECTRIC SERVICE ENTRANCE • • 0 TRANSFORMER ! • INTERIGRATED INTO IPS PANEL FIRE ALARM/ LIFE SAFTEY SYSTEM • • T.G.C. TO VERIFY IF IT 15 REQUIRED BY LANDLORD OR LOCAL BD. Q z ENERGY MANAGEMENT SYSTEM • • T6.C. TO VERIFY IF IT I'S REOUIRED BY LANDLORD OR LOCAL B.D. N 1LO MALL PLAN NO SCALE Ul MECHANICAL, PLUMBING PLANS POWER PLAN, NOTES, SCHEDULES LIGHTING PLAN, LEGEND, NOTES, SCHEDULES GROSS LEASE AREA GROSS SALES AREA NET SALES AREA NON -SALES AREA STORE DESIGN TYPE AREA CALCULATIONS Q ��11N111lH�1 Z 0 A) 'o U 0 �> cp Ill CA N 0 ' N ^ 1 V ttl _ a Z " .0 LU Ws u' s . C, An t P U =^ cn w 1-- v 64 ' 4 ^ C14 U_ Q (L -N 4 M U) LU I drawn by: PH I 1406 SQ.FT. 4/.e,5/u4FT. sate: 4,,5,u4 I Qsheet no: 1168 SQ.FT. 1065 SQ.FT. 238 SQ.FT. arch. project 04-1 _ �53 01-A • A6TERI5K INDIGATE5 NO REVISION MADE TO TH15 SHEET 0 W L UI 0 LLJ tiL) 00 U Q z p.- �V N 1LO �zo p ' Q o�Dj Zcr_ z I- LTJ LLJ V 0CL W G c) I (j) I drawn by: PH I 1406 SQ.FT. 4/.e,5/u4FT. sate: 4,,5,u4 I Qsheet no: 1168 SQ.FT. 1065 SQ.FT. 238 SQ.FT. arch. project 04-1 _ �53 01-A • A6TERI5K INDIGATE5 NO REVISION MADE TO TH15 SHEET P1'-2 B-2 FC -4 36'L. x 1 I/2' DIA GRAB BAR 48'L x i 1/2' DIA GRAB BAR - liv- IFS. ELECTRICAL CONTROL PANEL SEE SHEET E-1 EXISTING 6' MET STUD DEMISING WALL TO PROVIDE 5/8' GYPBOARD TO oM OF DECK ON S SIDE PER U.. fu_465. A4 %_ I 3 A2.1 6 r / M -13/4' LEASE LINE TO •� .TF-NANT 31'-60 ©.. EXIS EMISWS 400 WALL TENANT . PROVIDE LEASE LINE ® - E� � �:cisw�.'�"i;r��?'?�i�;.Y`e�i�u�Fti'fvt��✓'�.."C'G,s-�3�:s�e�'�".Yd"ea.�`,tS:•;r�i�!?" 3s'�?`y"'t.C4�+r_T:Cc:,rS-'w�-d">c�*r'�"::x{'r�r1'c.}::i�":':t.^-x+."'f.::;�t �� �,:�--�w'�.�."Swot`�.:.�<'��":�tii.V'�""G'.v:x':i'Y",.�il,'esflyi."l:vd ���,i.�t'.riW,.u�c;rnnwy-,-r..-t��."..':�X.,�S.i..:+',n!ti�:rT�-t;i�72"�z.il:f-m'`.'�,Gr:u:'t^S"5�-.,�?�T.:�1���.�i�� OARD To BOTTOM OF DECK ON - - %%"so# - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SLOPED - • . . .:• -0 ABOVE 'v lu I I I I LINE OF SLOPED - PLEXI MIRRORS I _ 5ALE5 AREA ABOVE CARPET FC -I LINE OF NEW TENANT'S - FLOORING, SEE I ENLARGED DETAIL ON I �I DWG. A3 r l I SLATWALL PANELS 4 A21 2 LINE OF G.U.B. ARE PROVIDED I SOFFIT ABOVE � BY TENANT AND I L:.J 3 INSTALLED BY W. - - 3 SW -h G.G. TO PROVIDE W BLOCKING FOR 2 LOCKERS AND LADDER HOOKS --------------- -------------- T --- - -- 1/8' �_ EXISTING 6' METAL STDEMISMG WALL ADJACENT TENANT 4 UD TENANT To PROVIDE 5/S' GYP00ARD TO A4 BOTTOM OF DECK ON TENANTS SIDE PER UL fu -465. CONSTRUCTION PLAN SCALE: 1/4' ■ I'-0' CEILING PLAN NOTES: L VERIFY WITH LANDLORD, METHOD OF ATTACHMENT FOR ALL ITEMS ANCHORED TO, OR SUSPENDED FROM THE EXISTING ROOF STRUCTURE. 2. THE TYPE AND LOCATION OF LIGHT FIXTURES SHALL BE AS INDICATED ON THE REFLECTED CEILING FLAN. REFER t0 ELECTRICAL DRAWINGS FOR ELECTRICAL- INFORMATION AND SPECIFICATIONS. 3. THE LOCATION OF HVAC DIFFUSERS SHAD. BE AS INDICATED ON 114E MECHANICAL HVAC DRAWINGS. 4. ELECTRICAL CONTRACTOR t0 COORDINATE LIGHT FIXTURES WITH CEILING TYPE SUBMIT SHOP DRAWINGS ON ALL FIXTURES, NOT A.RNISHED By TENANT PROJECT MANAGER TO TENANT'S GENERAL CONTRACTOR. WALL MOUNTED FAUX SECURITY CAMERA MOUNTED BELOW CEILING OILING At S'-0' AFF. 24'x 48' SUSPENDED WHITE ACOUST. TILE - CEILING AT 10'-0' AFF. LINE OF SLOPED PLEXI MIRRORS I ABOVE SLATWALL PANELS ARE PROVIDED BY TENANT AND INSTALLED BY G.C. - I I MT -I - --------- EEL TENANT TO PROVIDE A 4' CONCRETE SLAB ON GRADE REINFORCED W/ 6 X 6 - WI.4 X WI.4 W.UF. ON 6 MIL VAPOR BARRIER OVER 4' OF 1 COMPACTED w53 STONE A3. S. COORDINATE ANY NEW ROOF PENETRATIONS WITH LANDLORD AND a THE GiC: SHALL PROVIDE ACCESS PANELS M THE CEILING AND OR LANDLORD APPROVED ROOF CONTRACTOR BULKHEAD TO SERVICE EQUIPMENT IN THE CEILING SPACE INCLUDING, BUT 6. ALL STRUCTURAL FRAMING, I.14JJGERB, GaA1�lEL3, RODS AND OTI-ER NOT LIMITED TO HVAC UNIT, ROLLING GRILLE, JUNCTION BOXES AND MISCELLANEOUS SUPPORT STEEL SHALL BE FUII'AIIBHED AND INSTALLED BY YOLK DAMPERS. PANELS ARE t0 Flt FLUSH WITH THE CEILING, PAINTED THE GSC. AS NECESSARY FOR PROPER SUPPORT OF SUSPENDED/ TO MATCH ADJACENT AREA, CAULK ALL EDGES AND GAPS PROVIDE SUPPORTED EQUIM'IMENT AND SHALL BE FASTENED TO STEEL, CONCRETE,�� f'�S AS ta^EG.7♦..IRE BUT OF MINIMUM SIRE t0 SUIT INTENDED PURPOeE OR MIASONRY. G,G. t0 COORDINATE WITH STRUCTUIRAL ENGINEER AS al COORDINATE WITH ELECTRICAL, PLUMING, AND HVAC REQUIRED FOR INSTALLATION OF ALL EQUIPMENIT. OFZS. ALL PANELS ARE t0 BE FIELD LOCATED. FOR BIDDING PURPOSES, PROVIDE TWO (2) TOTAL LOCATED AT HARD 1. CEILING SHALL BE PLUM, LEVEL, AND SQUARE t0 ALL WALLS AND CEILINGS OR BULKHEAD ONLY. SOFFITS. 9, ALL NOTED CEILING DIMENSIONS ARE INDICATED AS CLEAR ABOVE FINISHED FLOOR DIMENSIONS. VERIFY THICKNESS OF FLOOR CONSTRUCTION WITH FLOORING SUBCONTRACTOR PRIOR TO THE INSTALLATION OF ANY NEW CEILING CONSTRUCTION IN ORDER TO ACHIEVE NOTED REQUIRED DIMENSIONS. r-%r--r-i r-r%-rrn nrl I I A Ir+ nl AAI SCALE. 1/4' • I'-0' CEILING W/ TEGULAR EDGE At 11'-0' AFF 0 EXISTING PIER ;t TENANT TO PROVIDE A N NEW 2' X 41/2' ALUMINUM STOREFRONT SYSTEM W/ I' INSULATED GLASS MT -2 TENANT TO PROVIDE PAIR OF GLASS DOORS MT -2 J 2 e J i J A3 EXTERIOR TENANT TO PROVIDE A NEW 2' X 4 1/2' ALUMINUM STOREFRONT SYSTEM W/ 1' INSULATED GLASS WALL TYPES LEGEND DEMISING WALL ME'T'AL STUDS WITH 5/8' FIRE RATED G.U.B. TIGHT TO STRUCTURE ABOVE, ONE HOUR FIRE RESISTANCE RATING, UL NO. U-465. IF DEMISMG WALL G.U.B. IS NOT YET INSTALLED, T.Ga TO PROVIDE AND INSTALL G.W.B. AND VERTICAL EXPANSION JOINTS, COMPLY W/ UL NO. U-465. DEMISING WALL STUDS TO UNDERSIDE OF DECK ARE PROVIDED AND INSTALLED BY LANDLORD. TENANT'S G.C. TO FIELD VERIFY AND REPORT TO ARCHITECT F DIFFERENT CONDITIONS EXIST BEFORE BEGIMIMG WORK 3 5/8' x 20 GA METAL STUDS AT 16' orm Ul/ 5/8' FIRE RATED G.U.B. ON ONE OR BOTH SIDES AS REQUIRED. ALL G.U.B. WITHIN TOILET ROOM TO BE WATERPROOF GREEN DOARD. GYP CEILING At 10'-10' AFF: PANT PT -1 G.W.B. SOFFIT AT 14'-0' AFF.- FAINT FF:PAINT PT -1 G.U$. SOFFIT AT 9'-10' Ar-P.- FAINT FF:PAINT PT -1 - : 3 114 715 1 =1. SIGNAGE 'J' BOX MOUNTED ABOVE SOFFIT, COORD. W/ ELECTRICAL PLANS G.W.B. SOFFIT AT 10'-0' AFF - FAINT PTA nnA lr%,rrm if%,rinAl nl AAI AInTr7c. UUIVJ I RUV I IIIN F I. -/"1I4 Ivv I L -v. L PATCH OR REPAIR EXISTING DEMISING WALL AS REQUIRED t0 MAINTAIN EXISTING FIRE RATINGS. IF DEMISING WALL Cs.WWB. MUST BE PROVIDED BY TENANT'S G.C, PROVIDE VERTICAL EXPANSION JOINTS EVERY 30'-0' (MIN) ALONG ENTIRE LENGTH OF EACH DEMISING WALL, CONTINUOUS TOP TO BOTTOM. 2. IF CUTTING IS REQUIRIp TO EXISTING FLOOR SLAB, CUT AND PATCH PER MALL CRITERIA COORDINATE WITH MALL REPRESENTATIVE. 3. METAL STUDS USED IN THE FRAMING OF STOREFRONT SHALL BE 3 5/8' X 18 GA AT 16' O.C. UNLESS OTHERWISE NOTED. 4. ALL RATED PARTITIONS SHALL BE 5/8' FIRE RATED GX5. ON METAL STUDS AT *'O.C. AND SHALL EXTEND TO UNDERSIDE OF STRUCTURE 5. NO COMBUSTIBLE MATERIALS SHALL BE ERECTED ABOVE CEILING. b. STOREFRONT SHALL BE SELF -SUPPORTED, BRACING TO STRUCTURE IS FOR LATERAL SUPPORT ONLY, UNLESS OTHERWISE NOTED. 1. SLATWALL INSTALLED N STOCKROOM TO 8'-6' AFF. - CmC TO ORDER SUFFICIENT AMOUNT FROM CLAIRVS. a RE E To FIXTURE PLAN FOR LAYOUT OF PERIMETER FIxll E SYSTEM. 9. TaG. To LAYOUT ALL WALLS AND PERIMETER BAYS PRIOR TO CONSTRUCTION. NOTIFY TENANT PROJECT MANAGER IMMEDIATELY OF ANY DISCREPANCIES. 10. ALL RADIAL DIMENSIONS ARE FOR LINEAL FEET OF WALL AND SHOULD BE VERIFIED/ COORDINATE WITH CSI PROJECT MANAGER PRIOR TO CONSTRUCTION. Il. T.G�C. SHALL VERIFY THAT DEMISING WALLS EXTEND t0 STRUCTURE ABOVE AND ALL PENETRATIONS ARE SEALED TIGHT, AND SHALL PROVIDE ALL WORK REQUIRED TO CORRECT DEFICIENT CONDITIONS. 12. ALL WALL FRAMING NOT BRACED t0 DEMISING WALLS SHALL BE SECURED OR DIAGONALLY BRACED AT 4'-0' TO STRUCTURE ABOVE. 13. DEMISING WALLS ARE NOT DESIGNED t0 ACCOMMODATE LOADWx ALL FIXTURES MUST BE SUPPORTED BY THE FLOOR OR NEW WALL CONSTRUCTION. 14. PROVIDE METAL OR F.R.T. WOOD BLOCKING FOR ALL SIGNS, HOOKS, AND ANY OTHER WALL MOUNTED EQUIPMENT. COORDINATE ALL BLOCKINGS REQUIRIB IENTS NECESSARY FOR MILLWOW, WITH MILLWORK SUPPLIER 15. ALL WOOD BLOCKING/ RARING USED N CONSTRUCTION TO BE FIRE RETARDANT TREATED. 16. ALL WORK AND EQUIPMENT SHOWN 18 NEW CONSTRUCTION BY TfmC. - UNLESS NOTED OTHERWISE TT, STOREFRONT METAL STUD FRAMING: USE 24' O.C. SPACING (TYPJ FOR ALL FRAMING M HOROXONTAL SOFFIT AND IN SALES AREA VERTICAL FASCIA USE I6' OAC. SPACING (TYPJ FOR ALL FRAMING IN VERTICAL MALL -FACING FASCIA AND SHOW-WNDOW FASCIA IS. SCREWS SHOULD GO STRAIGHT THROUGH SLATWALL PANELS AT BACK OF SLOTS: CLAIRE'S RCP SCHEDULE SYM30L TYPE Qty. DESCRIPTION O A X Ii' RECESSED DOWNLKsNT (VERSALITE) X GAM 1388 - ORANGE C X ,r 13 X 8' RECESSED E X GAM'990 - PURPLE ACCENTLIGHT (RECESSED X EM X V R CESSED EMERGENCY � ry VJ EXIT 8 EXW X EXIT, LED, ACRYLIC EDGE ELEV. U LIT, WALL RECESSED L1 EXM X EXIT AND EMERGENCY LIGHT I . Lf )Q U COh'IBO WIT WALL MOUNT z G X 4' 2 LAMP STRIP W cr H X 4'2 LAMP STAGGERED STRIP I� 0: Q FLUORESCENT LIGHT FIXTURES FACTORY - - - ♦ jr 1 J ATTACHED, STAGGERED 6', WALL MOUNTED: BEHIND MIRRORS - SEE DETAILS ON A4 FOR MOUNTING HEIGHT ® L X RECESSED FANLIGHT COMBO M X DOUWNLITE 0 RECESSED T N X 67X1' SEMI -RECESSED WALL WASH (CAVALETTO) O R X 2'X4' PRISMATIC LAYM, 3 LAMP T8 g X SPEAKERS, NORMALLY 2/8TORE INSTALLATION O� SPEAKERS, SPEAKER WIRE AND RELATED CONNECTIONS ARE TO BE BY T14E ELECTRICAL CONTRACTOR O - RECESSED SP. HEAD W+ WHITE POP-OFF CAP O - RECESSED SPRINKLER HEAD -CHROME • - PINION PENDANT SPRINKLER HEAD - CHROME COLORED SLEEVES, ( 48' LONG ) FSK' `GXL MOUNTED FLUORESCENT FIXTURE LAMPS. ALL COLOR DESIGNATIONS ARE FROM PANTONE MATCHING SYSTEMS. TA.C. TO INSTALL SLEEVES ON LAMPS AFTER FIXTURE INSTALLATION. A X GAM +450 - YELLOW B X GAM 1388 - ORANGE C X GAM 4195 - PINK D X GAM 4110 - FUSCIA E X GAM'990 - PURPLE F X GAM 0910 - LAVENDER AREA CALCULATIONS GROSS LEASE AREA - GROSS SALES AREA NET SALES AREA NON -SALES AREA STORE DESIGN TYPE - drawn by: PH date: 4/23/04 - 1406 SQ. FT. sheet no: - 1168 SQ. FT. - 1065 SQ. FT. - 238 SQ.FT. A 1 01-A arch. project - I D4-153:1 ASTERISK INDICATES NO REvISION MADE TO THIS SWEET r E E a E v! W 0. �0 J � ry VJ 0W `L 000 U Q L1 z I . Lf )Q U p Z_ z =� W cr H J W I� 0: Q U jr 1 J Q drawn by: PH date: 4/23/04 - 1406 SQ. FT. sheet no: - 1168 SQ. FT. - 1065 SQ. FT. - 238 SQ.FT. A 1 01-A arch. project - I D4-153:1 ASTERISK INDICATES NO REvISION MADE TO THIS SWEET r E E a E MATERIAL SCHEDULE: E.IF.S. SUPLLIED AND INSTALLED BY LANDLORD I � SUSPENDED CLAMS / 1=40ROTOTYPE ILLL M14ATED64K SHOP DRAWINGS t0 BE SUBMITTED SEPERATLEY BY SIGN VENDOR FOR REVIEW AND APPROVALS CAST STONE SUPLLIED AND NSTAL_LED BY LANDLORD Icings e -- -- NEUTRAL PIERS BY _-- LANDLORD - FILM APPLIED r0 INSIDE of - STOREFRONT GLAZING (EXCLUDE DOORS) FOR WINDOW TINTING BY TENANT- 1fi1-1 — / - - - - - -- - LINE OF CANOPY — —� — , -- - BOTTOM • 81-01 AFF. _ X14 reg / 1a re��' $I SHEET A3.1 CA 40PT" SIGNAGE - LETTERS ADAJAGENT /� ; RS TO BE 6' TENANT � � HIGH. SfLIKaCREIaI TO 'SKIRT OF CANOPY SYST4EMAUl MV NSUGLASS FRONT TEMPERED GLASS AND METAL DOORS 1'1T-2 STOREFRONT ELEVATION SCALE: 1/2' ■ 1'-0' DOOR HARDWARE TO MATCH DOOR FINISH REVERESEO VINYL DECALS ON INSIDE OF GLASS - INSTALLED BY GC. fi W W Z Z WW11V MPTAL C:LAlWS pRAP99. MPTAL 9t t pet.im a Nnsw- Mr- Al toms W z N O U 0 BASE W FLOOR COVERING z CEILING SLATWALL PAINT ..W ow PT -1 MANE SHERWIN WILLIAMS 8-I MATERIAL: PAINTED WOOD BASE MOULDING FC -I MATERIAL: CARPET C-1 MATERIAL: ACOUSTICAL SUSPENDED CEILING SW -1 MANUF: MARLITE WHITE COLOR PURE WHITE H FINISH: PAINT PT -2 MANE: SME: BENTLEY CUSTOM PATTERN MAJNUF. STYLE: ARMSTRONG FINE FISSURED (MEDIUM TEXTURE) COLOR NUMBER LAB OR NUMBER FINISH: BM91 LATEX - EGGSHELL LOCATION: NOTE: SALES AREA, REFER TO SPECIFICATION 064000 COLOR PURPLE CONFETTI (FIRE GUARD) MANF: MARLITE LOCATION: GENERAL WALL COLOR (SEE OWLS.) SP DWG'S. FOR MORE INFORMATION. TSR= 121262/011 SIZE/ NUMBER: 24 X 24 X 5/8 9833 C41 RAW UNFINISHED TYPE : 32 OZ. / YARN DYED / TIP SHEARED SIZE/ NUN" (BER 24 X 48 X 5/8 M834 -OR PT -2 MANUF: SHERWIN WILLIAMSB-2 MATERIAL: 4'H1. VINYL BASE REPEAT: 31 I/2' COLOR GRID: WHITE "'EXPOSED TEE GRID MIRROR LOCATION: STOCK ROOM DOOR AOR PUREWH1TE MANE ARMSTRONG NUMBER FINISH: 1004 OIL BASE, SEMI -GLOSS COLOR PAPZ MENT UA41TE FC -2 MATERIAL: MANF: TILE FLOORING MA STOREFRONT FINISHES M-1 SIZE: 24' DIAMETER LOCATION: RESTROOM, DOORFRAMES, NUMBER. LOCATION: 13 ALL NON -SALES AREAS, UNA. SME: SIRRAH / PORCELAIN TILE DESGRif''i': 1/4' CLEAR W/ POLISHED EDGE REAR DOOR AND BASE, 13-1 ONLY SIZE: 12' x 12' x 1/4' M? -I MATERIAL: METAL, FACTORY PANTED: COLOR ALMOND - ( TAN) POWDER COATING M-2 SIZE: I6' DIAMETER B-3 METAL. BASE FINISH: SEE MATERIAL MT -1 NUMBER: 30AL TIGER DRYLAC USA, INC. OESCRIPT. 1/4' CLEAR W/ POLISHED EDGE PT -3 MANUF: BENJAMIN MOORE MATERIAL: METAL, FACTORY PANTED: POWDER COATING GROUT: MAPEI, NO. 15 COLOR BONE ( OFF WHITE) RAL 9016 M-3 SIZE: 10' DIAMETER NUMBER= 2011 TIGER PRYLAC USA, INC. SEALER: FILA, NO. MP/90 METAU. FRONTS pESCRIPT: 1/4' CLEAR UJ/ POLISHED EDGE COLOR PMS' 2562C - 'AMETHYST CREAM' ( THIS COLOR MATCHES' ��' CONIF: COLOR LOCATION: LOC WHITE C. METAL STOREFRONT PANELS / MISTAL PARTS LIGHT FIXTURE RESIN FEATURE PANEL 'MA' - LAVENDER) MANF: METAL FRONTS FINISH: LATE( - EGGSHELL COLOR LOCATION: WHITE STOREFRONT AREA METAL BASE FC -3 MATERIAL: TjGC. TO MATCH EXISTING MALL FLOORING OR R -I MANUF. NEW BUISINESS SOLUTIONS, INC. LOCATION: ON WALLS, AS SHOWN IN ELEVATION EXISTING TOILET ROOM FLOORING DESGRIPT: 1/4 DISK M4NUF: T$Z>• Mt_2 MATERIAL. METAL, FACTORY PAINTED: COLOR PMIS 2166U 'LME' B-4 MATERIAL: CERAMIC TILE (DURA -FLOOR) 1'OUDER COATING PT -4 MANE BENJAMIN MOORS NOTEt OR EQUAL, AS APPROVED BY THE SME: COLOR T.B.D. T.B.D. TIGER DRYLAC USA, INC. R_2 MANUF: NEW BUISINESS SOLUTIONS, INC. NUMBER 2081-20 CLAIRE'S PROJECT MANAGEP. RAL 9016 DESCRIPT: 1/4 DISK COLOR: PMS • 20OU - `WATERMELON RED' MAJNUF: FRONTS COLOR PMS 1490 'CANTALOPE' ( THIS COLOR MATCHES MANF. DAL -TILE FC -4 MATERIAL: VINYL TILE COLOR WHIMMETA WHITE : NEW SOLUTIONS, INC. FEATURE PANEL 'LFIJB' - SALSA) SIZE: V4' X 6' X 6114. BULNIOSE MAN.F: ARMSTRONG LOCATION: METAL GLAZING FRAMES, HEADS, R_3 PESOMANU DEBCRIPT: I/4 DISK I DISK FINISH: LATEX - EGGSHELL COLOR ALMOND SIZE: 1/8' X 12' X 12' 15ASES COLOR PMS 2562 'GRAPE' LOCATION: ON WALL$, AS SHOWN IN ELEVATION NUIOER 2009 COLOR CLASSIC WHITE AUIHBER 51911 MT -3 MATERIAL: ALLMIN LM - BARE SWIRL -BRUSHED R-4 MANIF NEW 13UISINESS SOLUTIONS, INC. PT -5 MANUJF: BENJAMIN MOORE MANEMETAL FRONTS DESCRIPT: 1/4 DISK NUMBER. 2016-40 LOCATION: STOREFRONT PROJECTED SOFFIT COLOR PMS 178 C 'WATERMELON' COLOR PMS 0148U - `MARMALADE, ( THIS COLOR MATCHES WAINSCOT STOREFRONT GLASS TINTING FEATURE PANEL 'LFIlC' - MORNING BLUSH) FINISH: LATEX - EGGSHELLFM-I PL -1 SIZE: 4 -0 X 8 -0 (CUT t0 FIT) MATERIAL: FILMt SPECTRA SELECT 10 LOCATION: ON WALLS, AS SHOWN IN ELEVATION MATERIAL: PLASTIC LAMINATE BOARD MANF: VISTA WINDOW FILM MAJNUF. MARLITE N111BER VS -10 SR COF T$.D. DISTRIBUTOR Ci'F FILMS Pt -6 MANF: BENJAMIN MOORE COLOR. COLOR OFF WHITE LOG4TION: A ACCESSIBLE NUMBER k� NUMBER t$ D. DACE, ON EXTERIOR FROM INSIDE COLOR FMS • 5180 - 'GREEN' STOREFRONTS ONLY ( THIS COLOR MATCHES FEATURE PANEL 'L_FIJD' - CANTELOPE ) FINISH: LATEX - EGGSHELL LOCATION: ON WALLS, AS SHOWN IN ELEVATION E.IF.S. SUPLLIED AND INSTALLED BY LANDLORD I � SUSPENDED CLAMS / 1=40ROTOTYPE ILLL M14ATED64K SHOP DRAWINGS t0 BE SUBMITTED SEPERATLEY BY SIGN VENDOR FOR REVIEW AND APPROVALS CAST STONE SUPLLIED AND NSTAL_LED BY LANDLORD Icings e -- -- NEUTRAL PIERS BY _-- LANDLORD - FILM APPLIED r0 INSIDE of - STOREFRONT GLAZING (EXCLUDE DOORS) FOR WINDOW TINTING BY TENANT- 1fi1-1 — / - - - - - -- - LINE OF CANOPY — —� — , -- - BOTTOM • 81-01 AFF. _ X14 reg / 1a re��' $I SHEET A3.1 CA 40PT" SIGNAGE - LETTERS ADAJAGENT /� ; RS TO BE 6' TENANT � � HIGH. SfLIKaCREIaI TO 'SKIRT OF CANOPY SYST4EMAUl MV NSUGLASS FRONT TEMPERED GLASS AND METAL DOORS 1'1T-2 STOREFRONT ELEVATION SCALE: 1/2' ■ 1'-0' DOOR HARDWARE TO MATCH DOOR FINISH REVERESEO VINYL DECALS ON INSIDE OF GLASS - INSTALLED BY GC. fi W W Z Z WW11V MPTAL C:LAlWS pRAP99. MPTAL 9t t pet.im a Nnsw- Mr- Al toms W z N O U FRAMING. FINISH NOTES: I. THE TENANT'S GEI E CONTRACTOR SHALL BE RESPONSIBLE FOR a PROPER PREPARATION OF ALL NEW AND EXISTING SURFACES IN A a SATISFACTORY MANNER TO RECEIVE NEW FNISHES. THIS INCLUDES THE DEMOLITION AND REMOVAL OF NECESSARY ITEMS. TOUCH -Up AND/OR REFINISH OF SURFACES DAMAGED BY SUBSEQUENT WORK SHALL BE THE RESPONSIBILITY OF THE T,GjC. ALL WORK SHALL BE PERFORMED M C4 WITH THE MANUFACTURERS RECOMMENDED INSTALLATION ,U METHODS. THE GENERAL CONTRACTOR SHALL PREPARE THE EXISTING lu FLOOR PRIOR TO THE APPLICATION OF FINISH FLOORING. THE EXISTING U CONCRETE SLAB MUST BE SMOOTH AND LEVEL TO WITHIN A TOLERANCE OF C4 CA ONE-EIGHTH INCH PER FOOT. LATEX CEMENT PATCHING COMPOUND SHALLQ CA BE UTILIZED (NO ASPHALT BASED COMPOUNDS). N .. 04 2. ALL SURFACES WHICH ARE t0 RECEIVE A PAINT FINISH SHALL BE PRIMED w�- AND FINISHED IN ACCORDANCE WITH THE WRITTEN SPECIFICATIONS. lu 3. ALL JOINTS IN GYPSUM BOARD WALLS SHALL BE FINISHED WITH PAPER TAPE 2' WIDE AND THREE COATS OF VINYL, DRY OR PREMIXED JOINT w COMPOUND. ALL OUTSIDE CORNERS SHALL BE FINISHED WITH METAL COMM BEADS., TAPED AND SPACKLED. ALL AREAS r0 BE PAINTED pp�� SHALL 5E SANDED SMOOTH. JUST PRIOR t0 THE APPICATION OF THE FIRST O COAT OF PANT, WIPE SANDED SURFACES WITH A DAMP CLOTH IN ORDER TO LAY FLAT ANY NAP WHICH MAY NAVE FORMED IN SANDING. 4. FINISH FLOORNG INSTALLATION SHALL BE N CONFORMANCE WITH THE U Cq MAN.FACTU RER'S RECOMMENDED INSTALLATION GUIDELINES. COORDINATE 13N THE INSTALLATION WIN OTHER TRADES, SUCH AS ELECTRICAL. � 0_ 5. ALL JOINTS BETWEEN MATERIALS TO BE TIGHT AND CONSTRUCTED N A M - NEAT WORKMANLIKE MANNER U 6. ALL FINISHES $HALL BE TOUCHED UP TO CORRECT ANY IMPERFECTIONS_W � � '� ', U AFTER INSTALLATION. FIXTURE VENDOR $HALL PROVIDE TO THE T.GC. ALL MATERIALS FOR TOUCH UP WORK .. F- �Q I. THE INTENT OF THE FNISHI SPECIFICATION 18 TO PROVIDE A SATISFACTORY d x ,r m U - FINISH TO ALL PARTS OF THE WORK COVER ALL SURFACES THOROUGHLY. IF THE SPECIFIED N,NBER OF COATS DOES NOT ,ACCOMPLISH THE INTENT, THE v TfAC SHALL BE RESPONSIBLE FOR THE APPLICATION OF ADDITIONAL COATS OF THE SPECIFIED MATERIAL NO GIVE SATISFACTORY COVERAGE, AT NO ADDITIONAL COST TO THE OWNER 8 CLEAN ALL GLASS SURFACES WITH A LIQUID GLASS CLEANER At PROJECT y� COMPLETION. o► r 9. ALL FLOOR COVERING MATERIALS TO BE INSTALLED PER MANUFACTURER'S STANDARD DETAILS AND SPECIFICATIONS VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION. t•► C p U-- 10. USE ONLY CLEAR SILICONE SEALANT AS AN ADHESIVE ON THE 9 STOREFRONT METAL PANELS, CLADDING AND TRIM DO NOT USE CLEAR ® � SILICONE SEALANT ON THE STOREFRONT GLAZING//GLAZING FRAMES. 11. USE A FULL SHUT OF GYPSUM WALLBOARD, CUT 1' SHORT AT ALL FOUR SIDES AS A BACKING FOR ALL 3/4' THICK WHITE METAL PANELS. � � •� 12. FINAL TOUCH-UP TO WHITE METAL PANELS AND CLADDING/ TRIM STRIPS SHALL 13E DONE WITH THE MFR PROVIDED WHITE TOUCH-UP PAINT OR WITH WHITE SILICONE C4UIL.K, AS REQUIRED. mv in� en 0 W z FRAMING. FINISH NOTES: I. THE TENANT'S GEI E CONTRACTOR SHALL BE RESPONSIBLE FOR a PROPER PREPARATION OF ALL NEW AND EXISTING SURFACES IN A a SATISFACTORY MANNER TO RECEIVE NEW FNISHES. THIS INCLUDES THE DEMOLITION AND REMOVAL OF NECESSARY ITEMS. TOUCH -Up AND/OR REFINISH OF SURFACES DAMAGED BY SUBSEQUENT WORK SHALL BE THE RESPONSIBILITY OF THE T,GjC. ALL WORK SHALL BE PERFORMED M C4 WITH THE MANUFACTURERS RECOMMENDED INSTALLATION ,U METHODS. THE GENERAL CONTRACTOR SHALL PREPARE THE EXISTING lu FLOOR PRIOR TO THE APPLICATION OF FINISH FLOORING. THE EXISTING U CONCRETE SLAB MUST BE SMOOTH AND LEVEL TO WITHIN A TOLERANCE OF C4 CA ONE-EIGHTH INCH PER FOOT. LATEX CEMENT PATCHING COMPOUND SHALLQ CA BE UTILIZED (NO ASPHALT BASED COMPOUNDS). N .. 04 2. ALL SURFACES WHICH ARE t0 RECEIVE A PAINT FINISH SHALL BE PRIMED w�- AND FINISHED IN ACCORDANCE WITH THE WRITTEN SPECIFICATIONS. lu 3. ALL JOINTS IN GYPSUM BOARD WALLS SHALL BE FINISHED WITH PAPER TAPE 2' WIDE AND THREE COATS OF VINYL, DRY OR PREMIXED JOINT w COMPOUND. ALL OUTSIDE CORNERS SHALL BE FINISHED WITH METAL COMM BEADS., TAPED AND SPACKLED. ALL AREAS r0 BE PAINTED pp�� SHALL 5E SANDED SMOOTH. JUST PRIOR t0 THE APPICATION OF THE FIRST O COAT OF PANT, WIPE SANDED SURFACES WITH A DAMP CLOTH IN ORDER TO LAY FLAT ANY NAP WHICH MAY NAVE FORMED IN SANDING. 4. FINISH FLOORNG INSTALLATION SHALL BE N CONFORMANCE WITH THE U Cq MAN.FACTU RER'S RECOMMENDED INSTALLATION GUIDELINES. COORDINATE 13N THE INSTALLATION WIN OTHER TRADES, SUCH AS ELECTRICAL. � 0_ 5. ALL JOINTS BETWEEN MATERIALS TO BE TIGHT AND CONSTRUCTED N A M - NEAT WORKMANLIKE MANNER U 6. ALL FINISHES $HALL BE TOUCHED UP TO CORRECT ANY IMPERFECTIONS_W � � '� ', U AFTER INSTALLATION. FIXTURE VENDOR $HALL PROVIDE TO THE T.GC. ALL MATERIALS FOR TOUCH UP WORK .. F- �Q I. THE INTENT OF THE FNISHI SPECIFICATION 18 TO PROVIDE A SATISFACTORY d x ,r m U - FINISH TO ALL PARTS OF THE WORK COVER ALL SURFACES THOROUGHLY. IF THE SPECIFIED N,NBER OF COATS DOES NOT ,ACCOMPLISH THE INTENT, THE v TfAC SHALL BE RESPONSIBLE FOR THE APPLICATION OF ADDITIONAL COATS OF THE SPECIFIED MATERIAL NO GIVE SATISFACTORY COVERAGE, AT NO ADDITIONAL COST TO THE OWNER 8 CLEAN ALL GLASS SURFACES WITH A LIQUID GLASS CLEANER At PROJECT y� COMPLETION. o► r 9. ALL FLOOR COVERING MATERIALS TO BE INSTALLED PER MANUFACTURER'S STANDARD DETAILS AND SPECIFICATIONS VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION. t•► C p U-- 10. USE ONLY CLEAR SILICONE SEALANT AS AN ADHESIVE ON THE 9 STOREFRONT METAL PANELS, CLADDING AND TRIM DO NOT USE CLEAR ® � SILICONE SEALANT ON THE STOREFRONT GLAZING//GLAZING FRAMES. 11. USE A FULL SHUT OF GYPSUM WALLBOARD, CUT 1' SHORT AT ALL FOUR SIDES AS A BACKING FOR ALL 3/4' THICK WHITE METAL PANELS. � � •� 12. FINAL TOUCH-UP TO WHITE METAL PANELS AND CLADDING/ TRIM STRIPS SHALL 13E DONE WITH THE MFR PROVIDED WHITE TOUCH-UP PAINT OR WITH WHITE SILICONE C4UIL.K, AS REQUIRED. mv in� en CV Q 0 z U drawn by: PH date: 4/23/04 sheet no: L A2 arch. project 1 04-1-53 + ASTERISK INDICATES NO REVISION MADE TO THIS SWEET 0 N 9 U) W 0 ..W ow I* -U 00 Q z Lo Q W Q Ln� 0 0: Q o z z_i W 0 H W Q DC CV Q 0 z U drawn by: PH date: 4/23/04 sheet no: L A2 arch. project 1 04-1-53 + ASTERISK INDICATES NO REVISION MADE TO THIS SWEET 0 N 9 I SLOPED PLEXIGLAS MIRROR PANEL FA.IjC. (TYP. EACH END OF MOVEABLE PANELS) GJI1.B. WALL - PANT - PT -I SLATWALL - SW -1 4'H. WOOD BASE -PAINT B-1 53'-0' t 48'-0' (12) 4'-0' L. PANELS SNI MOUNTED FEATURE PANEL GF1.tD INTERIOR ELEVATION SCALE: 1/4' ■ 1'-0' SAO MOUNTED FEATURE PANEL GFI.IB $/W MOUNTED FEATURE PANEL (LFE) SLOPED PLEXIGLASS WATERPROOF 1 Esso MIRROR PANELS ON LAV AND SHELVES - PA METAL WALL CHAMEL EQ ROLL DISPENSER WATERPROOF - __ - - -- 36'L.1 1/2' DIA. - SEE DET. 5/A4 OC GRAB -BAR GM. - PANT BLOCKING (12) 4'-0' L. PANELS 2' X 4' ALUMNUM BETWEEN STUDS MIRROR WITHIN WALL FOR 6' STOREFRONT SYSTEM W/ GRAB -BAR SUPPORT BY GSC. 2 1' INSULATED GL466 z — J zo w� L—J LZ O v U W .. u V c� M h r O� O 4 m ' •Fa tv)�0� WHITE METAL PANEL N� -- - - - - - - - - -- - - - -- - - - - -------- MTp. t0 8/F WALL - SEE 95 M S/F SECTIONS FOR DIMS. - ON DUNG. A3-- - - - -- -- - — 6'14. WHITE PETAL 0 - — - - - - - — - - -- - - - _-- - _ _ ---- - ---_ -- -- - — - - --- - - - BASE B-3 ..(n �U) - - o w �U 00 S/I,W MOUNTED\—OMMOUNTED\_S/WMOUNTED FEATURE PANEL FEATURE PANEL FEATURE PANEL GEi) O CLFK)t 3 INTERIOR ELEVATION A2.1 SCALE: 1/4' ■ 1'-0' —MOCKING BY W. BETWEEN WATERPROOF STANDARDS SUPPORT, SEE 1 Esso 'GREENISOARD' G.W.B. LAV AND SHELVES - PA lRROR ROLL DISPENSER WATERPROOF - 1' -3' 36'L.1 1/2' DIA. AID' OC GRAB -BAR GM. - PANT BLOCKING 18' x 30' FRAMED PT -2 BETWEEN STUDS MIRROR WITHIN WALL FOR 6' t� GRAB -BAR SUPPORT BY GSC. 2 z — J —MOCKING BY W. BETWEEN STUDS UT14IN WALL FOR SHELVING STANDARDS SUPPORT, SEE 1 Esso FI)MM MOTE , ON Din's. FI LAV 4 PAPER TOWEL lRROR ROLL DISPENSER WATERPROOF - 1' -3' zQQ AID' OC GM. - PANT 18' x 30' FRAMED PT -2 � MIRROR a a 40 WATERPROOF MEM15RANE SEE WALL SECT. 34" B-2 E E 0 N N 42' MN. WALL MOUNTED WATER PAPER HEATER SEE DRAW1r M HOLDER OF W.C. 11WAP HOT WATER FC -4 1 AND DRAIN PIPE TOILET ROOM EL mTH INSULATION SCALE: 3/8' ■ 1'-0' i. 36' MAX. 48'L.1 1/2' DIA. GRAB -BAR BLOCKING BETWEEN STUDS WITHIN WALL FOR 12@ GRAB -BAR SUPPORT BY cn TOILET PAPER FC -4 B-2 HOLDER s TOILET ROOM ELEV. SCALE: 3/8' • 1'-0' SLOPED PLEXIGLASS MIRROR PANELS ON METAL WALL CHANNEL - SEE DET. 5/A4 2' X 4' ALUMINUM STOREFRONT SYSTEM W/ 1' INSULATED GLASS a MT -2 WHITE METAL PANELS MTD. TO S/F WALL - SEE SIF SECTIONS FOR DIMS. ON DWG. A3 MT -I 6'14. WHITE METAL BASE B_3 SLOPED PLEXIGLAS MIRROR PANEL FA.I.C. (TYR EACH END OF MOVEABLE PALLS) GIWB. WALL - PAINT - a SLATWALL - - 4'14. WOOD BASE -PANT B -I SUSPENDED EXIT SIGN G111.B.WALL -FAINT F� _QF_==�F---=__-l;__9 -II I IINDIVIDUALLY MOUNTED JI_ -.- _IL - - - - - J1- - -- 3-D LETTERS BY TENANT, �f—.--1F---- - -1(- - -- _ -1 I INSTALLED BY T.GrC. WHITE METAL CLADDING MTD. TO SIF WALL MT -I 2' X 4' ALUMINUM STOREFRONT SYSTEM W/ 1' INSULATED GLASS MT -2 REVERESED VINYL DECALS ON INSIDE OF GLASS - INSTALLED BY G.C. 6'H. WHITE METAL 0 WHITE METAL CLADDING MTD. TO S# WALL Mt -1 A o� TEMPERED GLASS AND METAL DOORS MT -2 FINISH rL BASE FLOC B-3 DOOR HARDWARE TO MATCH DOOR FINISH INTERIOR ELEVATION SCALE: V4' = 1'-0' REAR WALL SIGN BY - TENANT, INSTALLED BY TENANT'S SIGN VENDOR CENTER SIGN ON WALL 19'-0't SLOPED PLEXIGLASS EQ 5'-6' MIRROR PANEL `.' FA.IjC. (TYR EACH :t welcome to END OF MOVEABLE �, •� PANELS) in SLAn IALL - -- SW-I 4'14. x 1' WOOD - -- - - BASE -PAINT - - - INTERIOR ELEVATION SCALE: 1/4' ■ 1'-0' EQ SLOPED PLEXWA A88 MIRROR PANELS ON METAL WALL CHANNEL -SEE DET. 5/A4 L V -- - GX5. WALL - PAINT PT -1 -- \ 2'X VMI SEE DETAILS ON 2 DWG. A4 0 TWERMOSTAT w THANKS! EXF www.c 1 Esso U d O zQQ OC 0 U W � t� W 2 z zo w� LZ O U W .. u V c� 0 WHITE METAL CLADDING MTD. TO S# WALL Mt -1 A o� TEMPERED GLASS AND METAL DOORS MT -2 FINISH rL BASE FLOC B-3 DOOR HARDWARE TO MATCH DOOR FINISH INTERIOR ELEVATION SCALE: V4' = 1'-0' REAR WALL SIGN BY - TENANT, INSTALLED BY TENANT'S SIGN VENDOR CENTER SIGN ON WALL 19'-0't SLOPED PLEXIGLASS EQ 5'-6' MIRROR PANEL `.' FA.IjC. (TYR EACH :t welcome to END OF MOVEABLE �, •� PANELS) in SLAn IALL - -- SW-I 4'14. x 1' WOOD - -- - - BASE -PAINT - - - INTERIOR ELEVATION SCALE: 1/4' ■ 1'-0' EQ SLOPED PLEXWA A88 MIRROR PANELS ON METAL WALL CHANNEL -SEE DET. 5/A4 L V -- - GX5. WALL - PAINT PT -1 -- \ 2'X VMI SEE DETAILS ON 2 DWG. A4 0 TWERMOSTAT w z z w z U d O zQQ OC 0 U W � t� W 2 z zo w� O U W .. u V c� M h r O� O 4 m ' •Fa tv)�0� Lu N� 95 M LU 0 ..(n �U) o w �U 00 Q z Lo Q W Q N �� QD Q • o Z �z W0 w UJ Wfy 0 F- LIJLLI 2 Q F- Cn� U U U Cn revisions: checked by-. PH/JL drawn by: PH STAFF date: 4/23/04 sheet no: A2ml arch. projec A$TERISK INDICATES NO REVISION MADE TO THIS SHEET i a a a E E I 1' INSULATED — CA AZING WHITE METAL GLAZING STOP NEW 2' �U41TEE METHAL DOOR FRAME AND TEMP GLASS BY METAL STOREFRONT MANUFACTURER PROVIDED AND INSTALLLED BY TJS.C. 5/8' GYPBD ON 3-5/8'x 20 GA, METAL STUDS BY TENANT BLACK VINYL GLAZING STRIP (TYP) !7 NEW 4-V2' X 2' WHITE METAL GLAZING FRAMES BY METAL STOREFRONT MANUFACTURER PROVIDED AND 2 1/4' 2 1/4' INSTALLLED BY T.G.C. 4 V2' DETAIL @ DOOR HEAD SCALE: 3' = I'-0' PT -1 SEALANT AS REQ'D. (COLOR TO MATCH GLAZING FRAME (TYP-) NEW 4-1/2' X 2' WHITE METAL GLAZING FRAMES BY METAL STOREFRONT MANUFACR PROVIDED AND NST ED BY T.GjC. MT -2 WHITE METAL GLAZING STOP 41/2' N EXISTING STRUCTURE AND FLAT CONT. STEEL PLATE BY LANDLORD 14-0 AFF. BLACK VINYL GLAZNG STRIP (Tyra BLACK VINYL GLAZING STRIP (TYP-) AFF. NEW 4-1/2' X 2' WHITE METAL GLAZING FRAMES BY METAL STOREFRONT MANUFACTURER 2 114' 2 V4' PROVIDED *0 INSTALLLED BY T4C. 41/2' MT -2 DETAIL @ STOREFRONT HEAD SCALE: 3' ■ I'-0' MT -2 4 IR' LINE OF WHITE METAL CA.AZING FRAME 2 1/4' 2 V4' BEYOND BLACK VINYL GLAZING STRIP (TM�N7\—*-7 WHITE METAL I \ VIII GLAZING STOP —1 WHITE CAULK JOINT. (TYP.) Is INSULATED GLASS MT -2 NEW 4 V2' X 6' WHITE METAL GLAZING FRAME 13Y METAL SF MOO, PROVIDED AND INST. BY TA.C. 1/2 ' EXPANSION JOINT EXIST. SIDEWALK FINISH FLOOR � J � a d SILL ANCHOR a 4' SLAB BY TENANT ° ►a . a ° ° aq 4 DETAIL @ STOREFRONT BASE SCALE: 3' ■ 1'-0' ROOF, ROOF DEC STRUCTURE BY L 5/8' GYPBOARD ABOVE SEAL TI SAFMG METAL STUD DIA BRACING * 48' c 5/8' GYPBOARD 5/8' METAL SIM FRAMING BY TA? PAINT METAL STUD FIR O.C. EXTEND TO OF ROOF DECK (2)6'X15/8'X METAL STUD J011 ATTACH TO METS COLUMN BEYCH AFF. AFF. • SUSPENDED GY1 CEILING ON HAT CHANNELS 5!8' GYPBOARI 5/8' METAL STU[ RO IMG BY TA PAINT_( 3/4' DEET' MITI PALLS ON r2*1 GYPBOARD OV METAL FRAMING MT -1 WHITE METAL E B-3 TENANT TO POUT CONCRETE SLA W/ 6X6-WAA X C MIL VAPOR BAF 4' COMPACTED BY TENANT 453 STONE 2' X 4'-0' PERIMETER INSULATION BY TENANT L IF.S. AND STOREFRONT 3Y LATq_ORP *ANTED STEEL BEAM ORD 14'-0' AFF D SM BOX SIGN rOR TO SUBMIT DRAWINGS :W AND APPROVAL �' . AFF. Y WHITE METAL ' RAME WITH 1' TEMP GLASS SECTION THRU ENTRANCE DOORS SCALE: 3/4' ■ 1'-0' AFF. Y ,ANOPY AND ALUM. AmPLIED AND INSTALLED SIT. SEE DET. 5 ON SHT PIER BEYOND LORD ED / TEMP. GLASS, METAL BOORS, ALL RDWARE, F Oa G. VSION JOINT SIDEWALK BY LANDLORD ROOF, ROOF DECK AND STRUCTURE BY LANDLORD 5/8' GYPBOARD TO DECK ABOVE. SEAL TIGHT WITH FIRE SAFMG METAL STUD DIAGONAL BRACING * 48' O.G 5/8' GYP50AFO ON 3 5/8' METAL STUD FRAMING BY TANANT. PAINT METAL STUD FRAMING * 24' _ OAC. EXTEND TO BOTTOM OF ROOF DECK (2)6'XI"'X18GA METAL STUD JOISTS - ATTACH TO METAL STUD COLUMN BEYOND OIL AFF. SO -10 AFF., SUSPENDED GYPBD CEILING ON HAT CHANNELS 5/8' GYPBOARD ON 3 5/8' METAL STUD FRAMING BY TANANT. PANT 3/4' DEEP WHITE METAL PANELS ON 5/8' GYPBOARD OVER METAL FRAMING WHITE METAL BASE 8-3 TENANT TO POUR A 4' CONCRETE SLAB REINFORCED W/ 6X6-WAA X WI.4 W1UF. ON 6 MIL VAPOR BARRIER 1 Fl EXISTING ElP.S. AND STOREFRONT \zz FRAMING BY LANLORD EXISTING PANTED STEEL BEAM BY LANDLORD . \\2 - W (TYP) SCREWS \t �++� 14--0' --- -- - -1 AFF. A3 I i pmk � A3 AFF. 1' EQ 1' EQ I 4-1/2' X 2' WHITE METAL GLAZING FRAME UTH Is INSULATED TEMP GLASS 1 4 on S A3 AFF. r ;t ----- FABRIC CANOPY AND ALUM. FRAME. SUPPLIED AND INSTALLED BY TENANT. SEE DET. 5 ON SHT A3a �I I iI MT -I EXISTING PIER BEYOND BY LANDLORD C r 4-1/2' X 2' WHITE METAL GLAZING FRAME WITH 1' INSULATED TEMP GLASS MT -2 2 3 1/2' EXPANSION JOINT A3a � EXISTING SIDEWALK BY LANDLORD CARPET NEW FLOORING _ FC -1 T Fc -2 SECTION THRU STOREFRONT GLAZING SCALE: 3/4' ■ 1'-0' W z J Z3 U O er z���� �ww U� O U m M V N W- W z�Q W z �� W,L O w0 DC rj I ilOL 0 to u M40 tf� W u- 14 V O rn lu M 0..^� Nor NEEL uj UU) .. ♦^) � v! 0 LTJ tll-V Q 0o V z ,.. � QUQN VJ Q Z z w = — J z L�W ~ W W 0Q��U F-- U V U revisions: checked by: PH/JL drawn by: PH date: 4/23/04 sheet no: A3 arch. project II � A8TER15K INDICATES NO REVISION MADE TO THIS SHEET E WHITE METAL CLADDING_1 5/8' GYPBD ON 2 U 20 GA. METAL ST01 BY TENANT ' INSW-ATED GLASS NEW 4412' X 2' WHITI METAL CA AXING M BY METAL STORE" MANUFACTURER PR AND INSTALLLED B' TENANT P11'-2 FR BLOCKING, SEAT BAGGER ROD AS F (COLOR TO MATCH GLAzNG FRAME (r STOREFRONT JAMB DETAIL SCALE: 3' 2 1'-0' NEW FLOORINGS SET FLUSH WITH MALL EXTERIOR SLAB. METAL TRANSITION STRIP: BLANKEE CO. NO.21841010025 ALLMNIUM, F.O.t.C. t MECHANICALLY ANCHOR STRIP TO CONCRETE BY TLs.C. (SET CLOSE TO FLUSH W/ SURFACE OF NEW FLOORING) NEW CARPET NTRANCE FLOC (SEE PLAN) TAPERED LATEX a a UNDERLAYMENT Q a 4' SLAB BY TENANT — NOTE: PROVIDE TRIM o ° SPECIFIED N MAXIMLM LENGTHS AVAILABLE CONTACT MALL FOR FURTHER INFO. BRICK VENEER, INSULATION, "ATIHING AND METAL STUDS BY LANDLORD TfP. EQ 25'-4' 09 em EQ PLAN OF AWN INGs AWNING DETAILS SCALE: I' : 1'-0' FII�F VI I I"I�.I SIV AWNING COYER ON 315/8'X 20 GA. NEW tHRE81'IOLD METAL STUDS AT 24' O:C. MAX. Vi' EXPANSION JOINT DEEP METAL PANELS, *= SILICONE ON 5/8'"JI EXISTING SIDEWALK CLEATS -I - 1 1/Y METAL STRIP AT BACK OF REVEAL, MT -1 EXTERIOR - SILICONE ON GOB. SIDEWALK B-3 ° ° 6'x 3/4'METAL BASE, SILICONE a ON 5/8' MD.O. OR MARINE GRADE a a F.R.T. PLYWOOD CLEATS SILICONE SEAL AT FLOOR FNI8H FLOOR a 4 Q THRESHOLD/ FLOOR TRANSITION DETAIL SCALE: 3' • 1'-0' s,u nU w-MuwI I BASE DETAIL SCALE: 3' = 1'-0' LINE OF STOREFRONT SYSTEM LINE OF STOREFRONT SYSTEM LINE OF FABRIC CENTERLINE OF f AWNNCs COVER ALUMNILM AWNING SUPPORT PIPE FRAME \ (CURVES SPLINESt SEE SECTION DIAC~) CENTERLINE OF ALUMINIUM AWNING CENTERLINE OF I SUPPORT PIPE FRAME ALUMINIUM AWNING SUPPORT PIPE FRAME 1'-9' 5ECTION m NEW FABRIC AW NNGS WITH ALLMINILIM AWNINGS FRAMEWORK TO BE FABRICATED AND INSTALLED BY BLAIR SIGN CO. CONTACT: TOM GLUNT (814) 949-8281 FAX: (814) 949-8293 AWNING CONTRACTOR TO SUBMIT AWNING SHOP DRAWINGS TO TENANT'S GkC. FOR APPROVAL, PRIOR TO AWNING FABRICATION. CENTER 10' H. 0 'CLAIRE'S' LETTERS ON - FRONT OF AWNING SKIRT, PRINTED N CONTRASTING COLOR 6' METAL STUD DEMISING WALL BY J N LANDLORD. 5/8' GYPBOARD PER UL 465 BY TENANT ---'7—LEASE LINE W U tu z ' NO lu w t W ' EXISTING 6' X 6' TUBE • 1 •., t .M .. ♦. • • . ( •. I.. j . .lY STEEL COLUMN. :. Gua TO VERIFY U � w GYPBD TWT TO STRUCTLIRE ABOVE 3: UL 5/8' GYPBD ON 3 y 5/8'x 20 GA. METAL STUDS BY TENANT s DETAIL @ DEMISING WALL COLUMN All SCALE: 3' = 1'-0' MF in %lAl N etiunLL A3 OCA -Z: iia- • r-ra• O PROVIDE AND ETAL STUD .L TENANT TO ' TYPE X 'IGHT TO DECK NAM SIDE OF X465 CSA METAL STUD BOTH ENDS OF 3EARNG JOIST (2) BONE ATTACHED z BY --( AC w z J N z W U tu z ' NO lu w W U rj9 t IL tu ,n U � w 3: UL V ti y �r V T O �n C4 tti1 �r '4 MF in U) uj O .. � rU) vJ ow P --U Q U 00 L z Q LLI Q CV LO � <I OwWz0 W rr LuWLu Z 0 F- UUUUW < revisions: checked by: PH/JL drawn by: PH date: 4/23/04 sheet no: A3m 11 arch. project 4-16i] AOTERIP* INDICATE& NO FMV1510N MALE TO THI& SHEET a r r ATTACH CONTINUOUS TRACK WITH 20 GA METAL STRAPS TO BOTTOM OF OPEN WEB JOIST ABOVE - USE (2) NO 10 SCREWS INTO STRAPS AT 16' OjC. 24' X 48' SUSPENDED ACOUSTICAL TILE CEILING (WHITE) PT -I STRUCTURAL BRACING NOTE ALL METAL STUD BRACING SHALL BE MECHANICALLY r-ASTENED TO ROOF #L.00R DECK STRUCTURAL STEEL ABOVE. NOTHING SHALL MNENTRAT E OR ATTACH TO ROOF DECKt BRACE ONLY TO STRUCTURE SLATWALL SW -2 STOCKfi�00M 5/8' Ga1J.B ON 3 5/8' X 20 GA METAL STUDS AT 16' O.C„ Ga1LB. TO EXTEND t0 FLOOR ON BOTH SIMS OF WALL. ATTACH TO FLOOR WITH NO. (p CONCRETE ANC4M AND SCREWS At 30' O.C. EXISTING STRUCTURE ABOVE 24' X 24' SUSPENI ACOUSTICAL TILE (WHITE) SEE PLAN UNITE RECESSED LIGHT FIXTURE F �L J� .y ICN LIGHT SLOPED PLEXIGLASS MIRROR AND TRIM SLATWALL MOUNTED FEATURE I PANEL (BEYOND 5_. 5/8' G WJ3. ON 3 5/8' X 20 GA METAL STUDS AT I6' O.C. I SLATtUALL SU1-I I I 5 A4 5ALE5 AREA I IP X 4' WOOD BASE MOULDING -PAINT I B -I FC -4 5-2 7 FC -I SECTION: STOCKROOM/SALES SCALE: 3/4' ■ V -0 - EXISTING STRUCTURE ABOVE RECESSED FIXTURE EXOTNG STRUCTURE ABOVE 5/8' FIRE RATED GWa. IF NOT EXIST (SEE CONSTRUCTION PLAN NO rE 1, ON PM AU). EXISTING —24'x 24' SUISP. STRUCTURE ABOVE ACOUSTIC. TILE PT -I CEIL (WHITE) �L1J� lz SEE PLAN lo RECESSED LIGHT FIXTURE, SEE REFLECTED CEILING PLAN LIGHT CAA PLEXIGLASS MIRROR AND TRIM SLATWALL MOLINTED FEATURE PANEL (BEYOND) LF-• 5ALE5 AREA EXISTING b' METAL STUD DEMISING WALL. TENANT 0 TO PROVIDE 5/8' r GYPBOARD AND 3' SOUND ATTENUATING BATTS TO BOTTOM OF DECK ON TENANTS SIDE PER UL 'U-465. SLATWALL SL -1 IN 4' WOOD BASE MOULDING -PAINT I B -t FC -I IL .0 j F -t :r ................. / ..................... 11 SECTION: DEMISING WALL/SALES SCALE: 3/4' = 1'-0' 24" X 48" SUSPENDED TILE CEILING (WHITE) I v! LLJ I I CORNER MIRROR WALL 24' X 48" RETAINER (RIGHT), MOUNTED F'T-1 O SUSPENDED BOLTS AND TOGGLE NUTS CORNER MIRROR WALL ACOUSTICAL MI THRU GYP. BOARD RETAINER (LEFT), MOUNTED MIRROR PANELS TYPICAL FOR\—VERTICAL OULD 1�EPOSER8/l'tOW-DMG 11LE CEILING W/ N0.10 x 3-V2' ANCOOR ALL SEGMENTS, ULNA. (23-3/4'L. I EXPOSED W/ SILVER FINISH, BOLTS AND TOGGLE NUTS MIRROR PANELS ARE (WHITE) TRW GYP. BOARD AVAILABLE) U 5/8' Galla. ELEVATION �z LTJ ON 3 5/8' X 20 GA LLJ - LU t�C O�QC METAL STUDS AT 16' OL. - PLUMBING WALL TERPROOF ARD' 5/8' GiM. AT ALL TOILET MI. INTERIOR WALLS, F NOT EXISTING TOILET 5TOCKROOM NOTE: M"IN G FlXrimB 5/8' Ga11B. ON 3-5/8'X 20 CGA. NOT SHOWN FOR FURPM ES METAL STUDS AT Ib' O.C. OF CLARITY LEASE LINE VINYL BASE VINYL BASE VINYL BASE I B-2 FM -4B-2 B-2 FC -4 48'W. FRAME MIRROR STEEL WELDMENT SECGhENT$ 3/4' STEEL MIRROR WELD ENT FASTENED AT Ib' O.C. W/ NO 10 X 3-1/2' ANCHOR BOLTS AND TOGGLE NUTS THRU GYP BOARD. O FASTEN TO AJACENT ." SEGMENTS W/ (3 ) NO. 10 X 2' BOLTS W/ ( 2 ) WASHERS LOCK NUT PER BOLT tu- ACR MIRROR SECTIONS INSTAL BY INSERTING TOP EDGE N 'J' CHANNEL AND DROPPING BOTTOM of MIRROR PANEL INTO LOWER 'J' C IAN NEL OF MIRROR FRAME WELDMEJT MIRROR BANKS AGAINST FRAME WELD1" ENT TO INSTALL 1/8111 x 441L. PLASTIC SPACER STRIP IN FRONT OF MIRROR PANEL, PROVIDED BY Ol NER, BOTTOM OF ACRYLIC INSTL'D BY t�s:C. MIRROR PALL RESTING IN LOWER 'J' CHANNEL OF MIRROR FRAME LIELDMENT ''> CHRO4 ROUND -HEAD BOLTAAiHER BOLT GOES tHR1U/1!'ANFJ_ v SLATWALL MOUNTED :.� 5/8' G.W.B. OVER FEATURE PANEL, FDJ-C. i"ETAL STUDS AT Ib' O.C. SUPPORT DOWEL At MID PANEL (BY PANEL MFR.) ATTACH FASTENERS AT INSIDE OF GROOVE (TYPJ 'FEMALE' METAL MOLNTING BRACKET, WI.C. SEE NOTE 3. SLATWALL/MIRROR FRAME NOTES: L SLATWALL INSTALLATIONS SLATWALL PANEL, SEE NOTE I. THAT ARE SET LEVEL WITH A SW -I TRANSIT CAN BE UISEDE AS A "LIP RING' AND OUTLET BODY BASE LINE FOR MIRROR MOL14W AT HOLE CUT IN SLAT. FRAME INSTALLATION. WALL PANEL, MINWW SIZE HOLE 2. MINIMUM CLEARANCE REQUIRED. COVER HOLE AND OUTLET REQUIRED FROM THE TOP OF WITH FACE PLATE FLUSH WITH PANEL SLATWALL TO INSTALL FRAME SURFACE. CENTERLINE OF OUTLET AT WELDMENTS. IF THE SLATWALL 8' AFF (TYPJ N NOT LEVEL, INCREASE THIS DIMENSION, AS REQUIRED TO ; . I' X 4' WOOD MAKE THE WHOLE FRAME BASE MOULDING - MITER INSTALLATION LEVEL. p JOINTS AT 45 DEG. ANGLE B-1 3. T&C. TO ATTACH MOUNRNG io BRACKET TO STUD ATTACHED CARPET TO BACK OF FEATURE PANEL I N FIELD. :Ir W FC -1 1111111111111111111111111 Hill !'lllh 1-i 1111111111111111 d1 - 4 - 4 4. EXISTMG CONCRETE SLAB r� SLATWALL ANDMIRROR DETAIL CORNER MRROR PALL (RIGHT A4 SCALE. 3' ■ P-0' AND LEFT, UNIVERSAL) 3/4' STEEL MIRROR WELIP ENT FASTENED AT 16' O.C. WITH NO. 10 x 3-1/2' ANcWoR BOLTS AND TOGGLE NUTS 74W GYP. BOARD \ v! LLJ I I CORNER MIRROR WALL I RETAINER (RIGHT), MOUNTED O W/ NO. 10 x 3-I/2' ANC.0OR BOLTS AND TOGGLE NUTS CORNER MIRROR WALL 41-3/4L. X 23-9/16'W. ACRYLIC MI THRU GYP. BOARD RETAINER (LEFT), MOUNTED MIRROR PANELS TYPICAL FOR\—VERTICAL OULD 1�EPOSER8/l'tOW-DMG W/ N0.10 x 3-V2' ANCOOR ALL SEGMENTS, ULNA. (23-3/4'L. I EXPOSED W/ SILVER FINISH, BOLTS AND TOGGLE NUTS MIRROR PANELS ARE PRE -FINISHED BY I"FR TRW GYP. BOARD AVAILABLE) U MIRROR SYSTEM DETAIL ELEVATION A4 SCALE: 3/4' • I'-0' NEW 3/4' SLATWALL EXISTING PANELS (TYPJ DEMISING WALL 111/4 45 DEG MITRE CUT WHITE PLASTIC AT EACH BUTT CORNER TRIM (INSIDE . JOINT IN BASE COI'aNIER AND OLITSIVE CORNER) EDGE OF BASE BELOW, MITRE CUT AT 3/4 CORNERS SLATWALL CORNER DETAIL SCALE: 3' = 1'-0' INSIDE CORNER, 90 DEG. NEW 3/4' SLATWALL WHITE PLASTIC 5/8' ".13. PANELS (TYP) CORNER TRIM (INSIDE 45 MITRE GUT CORNER AND OUTSIDE 1 V4' DEG CORNER) EDGE OF BASE AT EACH BUTT BELOW, MITRE CUT AT revisions: JOINT IN BASE - CORNE" F7 checked by: PH/JL EXISTING ` pEM16MG WALL drawn by: PH STAFF 5/8' GaLLB date: 4/23/04 sheet no: 3/4 I- n .1�8 SLATWALL CORNER DETAIL SCALE: 3' • I'-0' OUTSIDE CORNER, 90 DEG. arch. project 64-15 ASTERISK INDICANS NO REVISION MADE TO THIS SHEET E a E r E I v! LLJ O ..U) r U) Ow LL 00 U Q z ISS U p O zwx �z LTJ Cr LLJ - LU t�C O�QC � DEG CORNER) EDGE OF BASE AT EACH BUTT BELOW, MITRE CUT AT revisions: JOINT IN BASE - CORNE" F7 checked by: PH/JL EXISTING ` pEM16MG WALL drawn by: PH STAFF 5/8' GaLLB date: 4/23/04 sheet no: 3/4 I- n .1�8 SLATWALL CORNER DETAIL SCALE: 3' • I'-0' OUTSIDE CORNER, 90 DEG. arch. project 64-15 ASTERISK INDICANS NO REVISION MADE TO THIS SHEET E a E r E I PRE -HUNG � • DOOR AND FRAME (EACH SIDE) I/4' MIRROR DOOR (AS SCHEDULED TYPE A ONLY 3 JAMB DETAIL A4.1 �-E' 3' • I'-0' 1/4' MIRPOR DOOR 5ALE5 TYPE A ON.Y SILICONE SEALED ALL MIRROR EDGES 61H. BRUSHED STAINLESS STEEL BASE PLATE - STOCKROOM FASTENED TO DOOR `MERCER' 0230 MONO EDGE: COLOR WI (BLACK) 4 DOM VINYL/ CARPET EDGE SILL DETAIL SCALE: 3' = I'-0' REGISTER COUNTER TYPE O SCANT *R BRACKETS, 1 PAIR —7,, �— 6'14. BRUSHED STAINLESS STEEL BASE PLATE - FASTENED TO DOOR DOOR ELEVATIONS SCALE: 3/4' = i'-0' 36' WIDE X 19' LONGS HNr-, ACCESSIBLE ROLL-OUT SHELF (RETRACTABLE) ATTACHED TO CENTER COUNTER FRONT PANEL, SHELF TOP At 34' AFF. u�l 3/4' W41TE PLASTIC EDGE 2'-3' FRAME MATL DETAILS c Tres. CAP TRIM AT TOP OF SAO d w TYP. � H,S. HEAD (CONTINUOUS ) SILL 0) 5/0' GYPSUM — WALL STOP: SW -I HARDWARE- METAL WALLBOARD MCKINNY 0TA2114105 45' x45' - 11/2 PAIR W/ ONE 3/A31 MATCH STOW"WINT SEE DOOR NOTE BELOW — — 2Q A 1 ° 3/4' WHITE PLASTIC A S.C. WOOD I WOOD jo�EDGE CAP TRIM 4/A4.1 SEE ELEVATION WOOD BLOCKING Q 30X 10 15/8' A S.C. WOOD 2 WOOD 2/A4.1 (SIM) n 4/A4.1 (SIM) PAINT PT -2 SEE ELEVATION - SIM. WOOD DOOR - PAINT GRADE 2 DOOR AND FRAME y SOLID CORE WOOD W/ WOOD A4.1 3/4' WHITE PLASTIC Lu VENEER PAINT BOTH SIDE EDGE CAP TRIM PT -1 1/4' MIRROR DOOR v! LLJ TYPE A ONLY nroo M -I ♦♦0 v! � v! ow EQ. EQ. 4' H. LETTERS (BLA 2 HEAD DETAIL 1,4-U 0V Q z LoQLuQN �? � Q o MIALLTICORRIDOR S A4.1 SCA -E' 3' ■ 1'-0' Ljj 1/4' CLEAR MIRROR WITH 0 7>— u WVUV� POLISHED EDGE ON SALES revisions: checked by: PH/JL drawn by: PH STAFF date: 4/23/04 SIDE ONLY. SUPPLIED AND arch. projectb4-153 INSTALLED BY G.C. BRUSHED ALUMW APPROVED DOOR B -I ONE 1' X 4' BASE BOARD SHALL HAVE BRUSHED STAINLESS P. LAMINATE ON BOTH STEEL PUSH PLATE EXPOSED ENDS OF 3 BOARD A4.1 -E SW -1 WOOD DOOR FRAME MAPLE TRIM - PAINT BOTH SIDES 5/8' GYPSUM PT_2 WALLBOARD DOOR AND FRAME PAINT BOTH SIDES METAL STUDS AT ::' 3/4' WHITE PLASTIC EDGE CAP TRIM GLUE !SILICONE) MIRRORS t0 PT -1 • 20 GA (TYPICAL) DOOR - TAPE TO DRY/ A4.1 SILICONE SEAL EDGES WOOD BLOCKING PRE -HUNG � • DOOR AND FRAME (EACH SIDE) I/4' MIRROR DOOR (AS SCHEDULED TYPE A ONLY 3 JAMB DETAIL A4.1 �-E' 3' • I'-0' 1/4' MIRPOR DOOR 5ALE5 TYPE A ON.Y SILICONE SEALED ALL MIRROR EDGES 61H. BRUSHED STAINLESS STEEL BASE PLATE - STOCKROOM FASTENED TO DOOR `MERCER' 0230 MONO EDGE: COLOR WI (BLACK) 4 DOM VINYL/ CARPET EDGE SILL DETAIL SCALE: 3' = I'-0' REGISTER COUNTER TYPE O SCANT *R BRACKETS, 1 PAIR —7,, �— 6'14. BRUSHED STAINLESS STEEL BASE PLATE - FASTENED TO DOOR DOOR ELEVATIONS SCALE: 3/4' = i'-0' 36' WIDE X 19' LONGS HNr-, ACCESSIBLE ROLL-OUT SHELF (RETRACTABLE) ATTACHED TO CENTER COUNTER FRONT PANEL, SHELF TOP At 34' AFF. u�l DOOR NO. 2'-3' FRAME MATL DETAILS c Tres. SIZE d w TYP. � H,S. FRONT ELEVATION CASHWRAP COUNTER ELEVATION AND SECTIONS SCALE: I' • I'-0' REGISTER COUNTER TYPE U SCANNER BRACKETS, 1 PAIR — , EMPLOYEE 51DE a 26' L2. 5ECT ION THRU 5HELF DOOR SCHEDULE DOOR NO. DOORS FRAME MATL DETAILS FINISHES REMAWS SIZE THK TYP. MATL H,S. HEAD JAMB SILL 0) (1).f X 9f — WALL STOP: ALUM. HARDWARE- METAL 5/A3 MCKINNY 0TA2114105 45' x45' - 11/2 PAIR W/ ONE 3/A31 MATCH STOW"WINT SEE DOOR NOTE BELOW — — 2Q A 1 ° 15/8' A S.C. WOOD I WOOD 2/A4.1 3/A4.1 4/A4.1 SEE ELEVATION SEE ELEVATION Q 30X 10 15/8' A S.C. WOOD 2 WOOD 2/A4.1 (SIM) 3/A4.1 (SIM) 4/A4.1 (SIM) PAINT PT -2 SEE ELEVATION - SIM. y O cn �q&L DOOR AND HARDWARE NOTES I. CLOSURES: FURNISHED AND INSTALLED BY TENANT'S ORAL. CONTRACTOR DOOR CLOSURES t0 BE MOUNTED ON ROOM SIDE OF DOORS. DOOR CLOSURES t0 HAVE A MAXIMUM OPENING FORCE OF 5 LBS. (INTERIOR HINGED DOORS). THE SWEEP PERIOD OF THE CLOSURE SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES, THE DOOR SHALL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3' FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR 2. TG;Z. SHALL PROVIDE KICKPLATES ON THE STOCKROOM SIDE OF THE EXTERIOR DOOR THE SALES/ STOCKROOM DOOR KICKPLATES SHALL BE ON THE PUSH SIDE OF THE DOOR 3. T.G.C. SHALL VERIFY WITH SUPPLIER THAT ALL HARDWARE MEETS ADAAG REQUIREMENTS. 4. ALL DOOR HINGES TO BE STEEL BALL BEARING, FULL MORTISE TYPE. S. ALL METAL DOOR FRAMES TO BE PROVIDED WITH SILENCERS. 6. ALL INTERIOR DOORS t0 BE PROVIDED WITH COMMERCIAL GRADE WALL OR FLOOR STOPS. 1. T.G.C. TO SUBMIT TYPE -WRITTEN SHOP DRAWINGS AND PRODUCT LITERATURE FOR ALL DOORS AND MAR[)WARE SPECIFIED. S. T.G.C. TO ENSURE ALL EXISTING DOORS t0 REMAIN t0 BE IN GOOD OPERATING ORDER AND t0 MEET CURRENT BUILDING CODES AND ADAAG REQUIREMENTS. ORAL CCNTRACTOR TO RESTORE DOOR AND HARDWARE TO 'L" NEW' CONDITION. 9 EXTERIOR HINGES TO HAVE NON-REMOVEABLE PINS. 10. ALL RATED DOORS TO BE SUPPLIED WITH THRESHOLDS AND GASKETS PER SPECIFICATIONS AND CODE. IL COORDINATE EXTERIOR DOOR DETAILS AND THRESHOLDS WITH LANDLORD. 12. DOORS AND FRAMES TO MATCH N COLOR UNLESS OTHERWISE NOTED. TOP OF CENTER COINTER ROLL-OUT SHELF TRACK 1'-1' 1. M 36' WIDE X 19' LONGS . ACCESSIBLE ROLL-OUT SHELF (RE TRACTABLE) ATTACHED TO CENTE RCICUNTER FRONT PANEL, SHELF TOP A'34' AFF. a C4 CU5TOMR 5 1 D E HARDWARE; STOCKROOM DOOR - SET NO. BUTT HIWC•IES: MCKINNY #rA211410B 45' x45' - 11/2 PAIR W/ ONE z z DOOR AND FRAME OPERATION: BROOKLINE'34C xUS26D - PUSH PLATE AND DOOR Z PULL W/ PLATE - 1 EA COORDINATE WITH EXIT DEVICE: ELEVATION. KICK PLATE: TICE PLKP 6' x 34' STAINLESS STEEL - 2 EA WALL STOP: IVES 043SxUS26D - 1 EA CLOSER LCN 0413314 W/ HOLD -OPEN ACTION - MOUNT 1 ON KICK PLATE: STOCKROOM SIDE. TAA. TO SET HOLD OPEN WALL STOP: ACTION HARDWARE- TOILET RM. DOOR - SET NO. 2 BUTT HINGES: MCKINNY 0TA2114105 45' x45' - 11/2 PAIR W/ ONE VIEWER: DOOR AND FRAME OPERATION: SCHLAGE jD91 PD - 1 EA. ROOM IDENT. SIGN: PLASTICS INDUSTRIES - TOILET'/ HC - 1 EA MOUNT AND GLASS DOORS NOTE ON STOCKROOM SIDE, BOT. AT 4'-0' APF WALL STOP: IVES 043SAJO26D - I EA HARDWARE: SERVICE DOOR - 5ET NO.3 BUTT HINGES: MCKINNY 0TA2114105 45' x45' - 11/2 PAIR W/ ONE z z DOOR AND FRAME OPERATION: NO HANDLE ON OUTSIDE, EXIT DEVICE ON INSIDE, Z SEE BELOW EXIT DEVICE: PANNI EX no. 1210A W/ I/C CORE HOUSING AND REMOTE U ALARM, MOUNTED NEAR THIS DOOR REPLACE EXISTING, AS REQUIRED, CONFIRM W/ CLAIRE'S z PROJECT MANAGER KICK PLATE: TICE PLKP 8' x 34' STAINLESS STEEL - 2 EA WALL STOP: IVES 04MAJO26D - 1 EA CLOSER: LCN 0413314 W/ HOLD -OPEN ACTION - MOUNT 1 ON STOCKROOM SIDE VIEWER: IVES'U`100 134 - MOUNT AT 4'-S' AFF. - I EA SMOKE GASKET: 36' x 18' PEMKO %M - I EA REPLACE EXISTING. MANUAL METAL AND GLASS DOORS NOTE 3/16' DOUBLE PANE TEMPERED GLASS / METAL DOOR WITH 6' BASE RAILS, 3-1/2' TOP RAILS ,AND 242' SIDE STILES, BUTTS, AND PUSH/PULL HANDLES. MANUALLY OPERATED KEY LOCK/CORE W/ EXTRA LONG THROW BOLTS ON DOOR STILE ON OUTSIDE WITH T14U'1B TURNS ON STORE SIDE BY BEST LOCK CORP. BEST 110 LOCKING SYSTEM. CLAIRE'S OPERATIONS MANAGER TO SUPPLY TENANT'S GENERAL CONTRACTOR WITH CONSTRUCTION CORES. DOORS HARDWARE FURNISHED AND INSTALLED BY TENANT'S GENERAL CONTRACTOR w w z z w Z J U z >�, ti w p U � 142 u� 01 c N Zlu � �� U w p O T u A .. U� w d � an U A y O cn �q&L Lu �r v! LLJ nroo ♦♦0 v! � v! ow 1,4-U 0V Q z LoQLuQN �? � Q o Q OW�zo Ljj Lu 0 7>— u WVUV� revisions: checked by: PH/JL drawn by: PH STAFF date: 4/23/04 sheet no: arch. projectb4-153 1 • ASTERISK INDICATES NO REVISION MADE TO THIS SHEET E a a E E m TYPICAL WALL SECTION NOTES: L ALL METAL STUDS TO BE CEMCO "3403-P 3 5/8' X 20 GAUGE AT 16' OjC. THROUGH= STORE AND 3 5/8' X 20 GAUGE AT 16' OjC. AT STOREFRONT UNLESS NOTED OTHERWISE. ALLOWABLE UNDRACEDD MIGHT AS PER CHART BELOW. METAL STIR SIZE MAXIMUM UNBRACED HEIGHT 3 5/8' X 25 GA Il' -3' 3 5/8' X 20 GA 14'-0' 3 5/8' X 16 GA 11'-0' 6' X 25 GA 16'-0' 6' X 20 GA 21'-0' 6' X 16 GA 25'-0' TABLE NO.2 ALLOWABLE SPACING FOR 1' LONG FASTENERS, INCHES 2. ALL CONNECTION AND FASTENERS TO BE AS PER DETAILS. ALL MANUFACTURERS AND LC$A. + TO BE STRICTLY ADHERED TO BY GLC UNLESS APPROVAL FOR EQUAL SUBSTITUTION IS RECEIVED FROM THE BUILDING DEPARTMENT. 3. ALL GYP. WALL BOARD TO BE 5/8' TYPE 'X' THROUGHOUT. ATTACH WITH I' TYPE S DRYWALL SCREWS 12' OL. VERTICALLY AT STUDS AND 8' O.G AROUND PERIMETER PARTITION 6'-0' 8'-0' TRACK 12 GA WIRE 12 GA WIRE NO. 18 GAUGE I NO. 20 GAUGE I NO. 22 GAUGE NO. 24 GAAE I NO. 26 GAUGE HEIGHI 10 GA WIRE* 14' 10 GA WIRE 25 GA STUD LOAD NORIAL TO WALL SURFACE ( f) 1 25 GA STUD (FT-) 5 10 15 5 10 15 5 10 15 5 10 I 15 15 10 15 6 42 42 42 42 42 42 42 42 33 42 31 24 42 23 B 8 42 42 34 42 42 31 42 31 25 42 21 18 34 T1 it 10 42 41 21 42 38 25 42 30 20 42 22 14 21 13 S 12 42 134 122 42 131 121 1 42 125 16 31 18 12 23 11 15 14 42 2-3 1 IS 42 121 118 142 121 14 31 15 10 15 95 65 16 42 125 1 11 42 123 115 131 118 112 121 13 19 1 Ti 18.5 15.5 WALL ANCHORAGE TABLES SCALE: NO SCALE Q:::3 - - LEVER 34' TO 48' AFF. ENTRANCES. ALL PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES ARE REQUIRED TO BE MADE ACCESSIBLE. A PRIMARY ENTRANCE 15 DEFINED AS, '-ANY ENTRANCE TO A FACILITY WHICH HAS A SUBSTANTIAL FLOW OF PEDEST- RIANS TO ANY SPECIFIC MAJOR FUNCTION OF THE FACILITY.' REVOLVING DOORS CAN NOT BE USED AS A REQUIRED ENTRANCE FOR THE HANDICAPPED. RECESSED DOORMATS ARE REQUIRED TO BE ANCHORED TO PREVENT WITH WHEELCHAIR TRAFFIC. DOOR WIDTHS AND HEIGHTS.REQUIRED EXIT DOORWAYS ARE REQUIRED TO HAVE A CLEAR OPENING NOT LESS THAN 32 INCHES WIDE. FOR HINGED 000R8, THE OPENING IS MEASURED WITH THE DOOR AT A W DEGREE ANGLE FROM ITS CLOSED POSITION. AT LEAST OPE OF A PAIR OF DOORS, INCLUDING AUTOMATIC DOORS, HAS TO PROVIDE TINE 32 W-44 CLEAR OPENING. DOOR 1 -EIGHTS ARE REQUIRED TO BE A MINIMUM OF 80 INCHES. ALTHOUGH SECTION 33 RELATES TO REQUIRED EXITS, ARTICLES 6 THROUGH 14 ALSO REQUIRE SPECIFIC AREAS TO BE ACCESSIBLE. DOORS TO TSE AREAS WOULD ALSO HAVE TO HAVE A 32 INCH CLEAR OPENING. THE STATE ARCHITECT NOTED DURIP1G THE HEARINGS THAT A 6'-8' DOOR WOULD BE ACCEPTABLEt THE 5/8' INCH STOP WOULD NOT BE CONSIDERED. THRESHOLDS. THRESHOLDS ARE REQUIRED TO BE NO MORE THAN I/2 INCH W&L BEVEL OR SLOPE THE EXPOSED EDGE AT AN ANGLE NOT EXCEEDING 45 DEGREES SO THAT NO SINGLE VERTICAL. CHANGE OF ELEVATION EXCEEDS U4' NCH, L EXIT DOORS, TOILET ROOM AND CHANGING ROOM DOOR TO BE OPENABLE FROM INSIDE WITHOUT SPECIAL KNOWLEDGE, FORCE OR PEED OF KEY. 2. SEE SPECIFICATION SHEET FOR RESPONSIBILITIES. 3. ALL HARDWARE TO BE LEVER TYPE PER TITLE 24. r 1� I,rWM., WALL HEIGHT 6'-0' 8'-0' UP TO 10' 12 GA WIRE 12 GA WIRE 12' 10 GA WIRE 10 GA WIRE* 14' 10 GA WIRE 25 GA STUD ib'1 10 GA WIRE 1 25 GA STUD U E'AlIJIInW110ZcM.22;EFT Pj3R2111A r $EE DOOR SCHED CLEAR DOOR CLOSERS: SHALL BE ADJUSTED SO THAT THE OPENING EFFORT DOES NOT EXCEED 5 be. FOR INTERIOR DOM, 85 be. FOR EXTERIOR DOORS, AND 15 be. FOR REQUIRED FIRE DOORS. REF: 2-3304(1)2. HARDWARE.HAND ACTIVATED DOOR OPENING HARDWARE IS REQUIRED TO BE CENTERED BETWEEN 30 AND 44 INCHES NIGH. LATCHING AND LOCK- ING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL NAVE TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPEN- ING HARDWARE. LOCKED EXIT DOORS ARE REQUIRED TO OPERATE AT DESCRIBED ABOVE IN THE DIRECTION OF EGRESS. CLOSERS. THE MAXIMUM EFFORT TO OPERATE DOORS CANNOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, REQUIRED FIRE DOORS MAY REQUIRED UF' TO B POUNDS PRESSURE THE PRESSURE IS TO BE MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE REQUIREMENTS. DOOR HARDWARE NOTES SCALE: NO SCALE PHISH AS PER PLANS AND SECTIONS METAL STUD PRAMING REFER TO NOTES AND PLANS FOR SIZE, G4UGE, AND SPACING 08 SCREWS EA SIDE OF STUD TO TRACK (TYP-) 3 5/8' OR 6' (SEE — PLANS) CEMO 25 GA TRACK (TYPJ UNLESS NOTED OTHERWISE IJC$A. + ER 1115 CONCRETE SLAB it FLOOR FINISH - d. a d M DIA HILTI POWDER d v ACTUATED FASTENER w/ A a a 3/4' EMBEDMENT AT 24' a a O.C. ICBO 4ER 2388 FLOOR TRACK DETAIL SCALE: NO SCALE 0 .w.fA Ohl j mt.A rah :ECK WALL SECTION SCALE: I'■I'•0' U2' CLEAR BRIDGING AT 8' FROM — TOP PER MANUFACTURER'S RECOMMENDATION I/2' CLEAR 3 5/8' M. STUDS AT 16' O C. 3 5/8' x 25 GA w/ (1) 3/16' . PAF. AT EACH M. ATTACH TO TRACK w/ 08 SCREWS AT 24' OiC. BOTTOM OF STRUCTURE NG DEMISING WALL rPE 'X' GNU$. ON METAL STUDS OJ✓, UL 11.1-465 EXISTING STRUCTURE CONTINUOUS 18 GA DEEP LEG TRACK SLIP CONNECTION EACH SIDE OF STUD (TYP) 3 5/8' METAL STUDS AT 16' Ojr. PARALLEL TO STRUCTURE EXISTING STRUCTURE 3 5/8' X 20 GA W/ (1) 3/16' . PAF. AT EACH END. ATTACH TO TRACK W/ 08 SCREWS AT 24' O.C. CONTINUOUS 16 GA DEEP LEG TRACK SLIP CONNECTION EACH SIDE OF STUD (TYPJ BRIDGING AT 8' FROM TOP PER MANUFACTURER'S RECOMrENPATION PERPENDICULAR TO STRUCTURE CONNECTION DETAILS SCALE: 38811-01 '■1'-0' Cz W Z_ 9 W O d _z o� U W W O OpC CA W UC C Ci °u EL r C4 M.. SD 0 Q * d y� o► a� O cn -Ia A A W d AV in lqqw U) LIJ x 0 ..U) oc U) 0 W L`' o U V LoQWQN ��Q OQ z Lu W J 0 Z xF— 0 W ><-V W U) Q�CQ C-) revisions: checked by: PH/JL drawn by: PH STAFF date: 4/23/04 sheet no: arch. Project- rojects 4-153 -1 md A CtCbIQY Wfi 1, -ATC& AV^ bC. AQli l MA' = -r 1 -1-1 114L CI Ittt r E a a E E a EQ 9-m FIXTURE/FURNISHINGS PLAN SCALE: 1/4'a 1'-0' FIXTURE FURNISHINGS SCHEDULE ITEM W. /-� DESCRIPTION / SM COUNT SUPPLIED INSTALLED BY BY COLOR / REMARKS LFI.1,4 I 2'X 1' FE ATURE PANEL 1 FI.15 LF1.IC T.G.C. LAVENDER I 3 LF4Id LF4.0 T. LF3.0 LF2.1 717 2 4� 11 [j] LF3.0 L 0 I LF5.0 X LF2.1 LF1,0 CE) MORNING BLUSH LF -6.1 4 LFI2D 1E]( LF40 -- ❑ � \ i -i 5'-0' AD LFILO �� 1 �� LR2A 6 i i i i 9 I LF12A LF3Id LFL25 I =LF30 \ LF3Ja "I� loo, LF3fd LR25 I LF5.0 I 8 ' LF4.0 LF4Ja � LF2 .1 C-3 LF3.0 L#-"1.1 O � r LF4fd LF131d LF4fa 10 I 5 I T. TG.0 MORNING BLUSH 056 i - - - � LF1JD - - - - - - - - - LFLIA LFLIB - - - - - - TGC F40 - FIXTURE/FURNISHINGS PLAN SCALE: 1/4'a 1'-0' F I XTURE/FURN 15 1 ING5 FLAN NOTE5: FIXTURES SNOM FOR INTENT OF DESIGN ONLY. TGC. TO COORDINATE WITH OUTER FOR EXACT PLANT OF FIXIURES. ADA CLEARANCES SHALL BE MAINTAINED. L CASH WRAP - COORDINATE WITH ELECTRIC SUPPLY. SUPPLIER TO SET AND INSTALL CAS14VAP. TGjr, TO COORDINATE ELECTRIC WORK AND FIELD CUTTING (IF REaRRED) UT14 CASH WRAP SUPPLIERS SEE CASH WRAP WIRING DIAGRAM ON El 2. FOR LOOSE FD(TURE DEWSNATIONS, SEE FIX11M 80EDU-E. 3. SECURE ALL FIJ,12 AND 13 PERIMETER WALL FIX PA40 TO THE SLATWaLL. COORDINATE LOCATION UT14 STORE DESIGN. 4. FIRE EXTINGUISHER LOCATION, RETAIL AREA - MOUNT AS DIRECTED BY FIRE MARSHAL. 5. TAC. TO SECURE A 12'X 18'X 3/4' FRT. PLYWOOD TO THE WALL BEHIND LOCKER 6' DOWN FROM TOP OF LOCKER FOR ATTACHMENT TO WALL. ATTACH F.R.T. PLYWOOD TO METAL STUDS U11T14N WALL AT FOUR LOCATIONS, MN. 6. 12'X 36' X 3/4' MT. PLYWOOD ( 3 ) SHELF WITH SURFACE MOUNTED SLOTTED WALL STANDARDS "LF BRACKETS AND HOLD CLIPS SUPPLIED BY TGC., INSTALLED BY TG.C. BOT. SHELF AT 4'-8' AFF. PANT SHELF PT -2. 1. MOUNT TWO NOOKS INTO SLATWALL AT 12' OjC BOT. OF HOOKS AT 6'-0' AFF. THE ACTUAL MOUNTING LOCATION N PLAN, NOOK MOUNTING NEe*M AND CONFIGURATION SHALL 5E COORDINATED WITH THE STORE MANAGER, PRIOR TO INSTALLATION 5Y GC. W W Z FIXTURE FURNISHINGS SCHEDULE ITEM W. /-� DESCRIPTION / SM COUNT SUPPLIED INSTALLED BY BY COLOR / REMARKS LFUA 2'X 1' FE ATURE PANEL 1 T. T.G.C. LAVENDER LFU15 2' X 1' FEATURE PANEL 1 T. TGC $ALSA LFUC 2'X 1' FEATURE PANEL X T. TG.C. MORNING BLUSH LFi D 2'X 1' FEATURE PANEL X T. TG.0 HONEY DO LR2A 3' X 3'-6' FEATURE PANEL I T. TGC LAVENDER LR25 3' X V-6' FEATURE PALL I T. TGC SALSA LR2C 3' X 3'-6' FEATURE PANEL I T. TG.0 MORNING BLUSH 056 3' X 3'-6' FEATURE PANEL 1 T. TGC HONEY DO LR3A 3' X 5' FEATURE PANEL X T. T.G.C. LAVENDER LFU S 3' X 5' FEATURE PANEL X T. TGC $ALSA LFU'!C 3' X 5' FEATURE PANEL X T. Tia c. MORNING BLUSH LFl3D 3' X 5' FEATURE PANEL X T. T�G.0 HONEY DO LF20 36' MARAIIEE DISPLAY X T. T. LF2J 18' MARQUEE DISPLAY 3 t. T. O Z LF3o 18' X 18' SQUARE TOWER 8 T. t. 040 EARRING TREE 5 t. t. arch. projectb4.153 LF50 FEATURE TABLE I T. T. 56O0 EAR PIERCING UNIT I T. T. CONTRACTOR TO ASSEM5LE LF6.1 EAR PIERCING CHAIR I T. T. LFI0 CASHWRAP (ONE PIECE) 1 T. TGC. Lru BA XJXAP 1 T. TGC. LFA SIDEWRAP X T. TGC. LFI,O PRECIOUS METAL FIXTUM 1 T. TGC. EXISTING LFD0 COUNTER SPIMERS 2 T. TGC. LFt30 REAL BODY JEWELRY FIXTURE I T. TGC, EXISTING LFKAV SLATWALL PANEL FIXTURE X T. TGC. I COAT NOOKS 51RAC.KET l NON -SALES) 1 Tj3C. TGC. 'BOBRICK' 1'5-232 x 24' 2 SCANNER BRACKETS ON CAS 41RAP I T. TGC. ( I PAIR BRACKETS ) SEE CAS1URAP ELEVATION DETAIL ON OW. El 3 FIRE EXTINGUISHER 2 Ta.C. TGC. COORDINATE LOCATION W/ LOCAL OFFICIAL 4 STEREO SHELF I T. TGC. 5 EMPLOYEE LOCKER 1 T. TG.C. SEE NOTE NO.5 6 COAT NOGG WITH alllMR I TJSJC. TGjc, SEE WEET 0402, DIV. 10800 1 PAPER TOWEL ROLL HOLDER I TGC. TGC. MOUNTING DIGHT - 130T. AT 40' AFF. a SUPPLY SHELVES I TSC. TGC. SEE NOTE NO.6 9 STEREO RECEIVER 1 T. TGC. WIRES PROVIDED W/ SPEAKERS, i6 LADDER HOOKS 2 TGC. TGC. "RAIIFORD' 48811-50 ( 2 PER LADDER ), SEE NOTE 1 11 SECURITY DOME w/ L.E.D. LIGHT I T. TGC. THE L.E.D. LIGHT IS BATTERY POWERED ( NO ELECTRICAL- NOCK -UP REQUIRED) SECURITY CAMERA (FAUX) I T. j TGC. U&L MOUNTED (NO ELECTRICAL HOOK-UP REQUIRED-) F I XTURE/FURN 15 1 ING5 FLAN NOTE5: FIXTURES SNOM FOR INTENT OF DESIGN ONLY. TGC. TO COORDINATE WITH OUTER FOR EXACT PLANT OF FIXIURES. ADA CLEARANCES SHALL BE MAINTAINED. L CASH WRAP - COORDINATE WITH ELECTRIC SUPPLY. SUPPLIER TO SET AND INSTALL CAS14VAP. TGjr, TO COORDINATE ELECTRIC WORK AND FIELD CUTTING (IF REaRRED) UT14 CASH WRAP SUPPLIERS SEE CASH WRAP WIRING DIAGRAM ON El 2. FOR LOOSE FD(TURE DEWSNATIONS, SEE FIX11M 80EDU-E. 3. SECURE ALL FIJ,12 AND 13 PERIMETER WALL FIX PA40 TO THE SLATWaLL. COORDINATE LOCATION UT14 STORE DESIGN. 4. FIRE EXTINGUISHER LOCATION, RETAIL AREA - MOUNT AS DIRECTED BY FIRE MARSHAL. 5. TAC. TO SECURE A 12'X 18'X 3/4' FRT. PLYWOOD TO THE WALL BEHIND LOCKER 6' DOWN FROM TOP OF LOCKER FOR ATTACHMENT TO WALL. ATTACH F.R.T. PLYWOOD TO METAL STUDS U11T14N WALL AT FOUR LOCATIONS, MN. 6. 12'X 36' X 3/4' MT. PLYWOOD ( 3 ) SHELF WITH SURFACE MOUNTED SLOTTED WALL STANDARDS "LF BRACKETS AND HOLD CLIPS SUPPLIED BY TGC., INSTALLED BY TG.C. BOT. SHELF AT 4'-8' AFF. PANT SHELF PT -2. 1. MOUNT TWO NOOKS INTO SLATWALL AT 12' OjC BOT. OF HOOKS AT 6'-0' AFF. THE ACTUAL MOUNTING LOCATION N PLAN, NOOK MOUNTING NEe*M AND CONFIGURATION SHALL 5E COORDINATED WITH THE STORE MANAGER, PRIOR TO INSTALLATION 5Y GC. W W Z z w Ell 0 u a 0 z 0 U -- L) <S::::) O c� U QC � Lu z .j, U w `n v b p� r O Cn •la ,Q u. Luo �r d 1WAV Im dpi CA v! uj nro0 r� v! 0 w �U 00 1.n Q U Z Q Lu QN � (/) Q 0 Q z W CCLLJ ,� W J O Z 0:� F- W Q LL! Q F- U)UUU� revisions: checked by: PH/JL drawn by: PH date: 4/23/04 sheet no: arch. projectb4.153 M.71CR1".71� II`/VI%. ANl=.7 IVV IV In. -7 . TCG E r E E Q I E 00100 r. aei CONDITIONS, AS NDICATED N THE AID DOCUMENT'A201 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION' 1987 EDITION. 00w0 6Lpf LEMENTARr CONDITIONS: 00810 MODIFICATIONS TO GENERAL CONDITIONS.- ARTICLE ONDITIONS:ARTICLE 4 4A.1 ADD THE FOLLOWING. UTILITIES SHALL INCLUDE A JOB TELEPHONE TO BE INSTALLED WITHIN FIVE (5) WORKING DAYS AFTER COMMENCEMLENT OF THE WORK. COORDINATE WITH TENANT UTILITY MANAGER + (954) 4333435. 4.10.1 ADD THE FOLLOWING: CONTRACTOR SHALL SUPPLY CLAIRE'S WITH A COMPLETE LIST OF ALL SUB -CONTRACTORS INVOLVED WITH THE WORK (NAME, ADDRESS AND TELEPHONE NU MBER)WITH SECOND APPLICATION FOR PAYMENT . SEND TWO COPIES TO THE HOME OFFICE, ATTENTION STORE PLANNING HVAC AND W.W. HEATER W014 NATION MUST BE NOTED. RE ER TO TENANT FORM. 01010 WORK OF CONTRACT CAN BE SUMMARIZED LBY REFERENCE t0 THE CONTRACT, GENERAL, CONDITIONS, SPECIFICATIONS, DRAM", ADDENDA AND MODIFICATIONS t0 THESE DOCUMENTS ISSUED SUBSEQUENT t0 THE NITIAL PRINTING OF SAME. A RESPONSIBILITY SCHEDULE IS INDICATED ON THE PLANS. IT INCLUDES COORDINATION WITH OTHER WORK PERFORMED BY SEPARATE CONTRACTORS OF THE PROJECT. CONTRACTOR RESPONSIBILITY: GENERAL CONTRACTOR SHALL PROVIDE AND PAY FOR: LABOR, MATERIAL, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT, MACMNERY, WATER NEAT AND UTILITIES REQUIRED FOR CONSTRUCTION AS WELL AS ANY OTHER FACILITIES AND SERVICE NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK WHEN WORK IS PERFORMED IN AN EXISTING STORE, PROVISIONS CAN BE MADE TO USE EXISTING UTILITIES, EXCEPT TELEPHONE, AND BILLS WILL BE PAID DIRECTLY BY TENANT. COORDINATE WITH TENANT UTILITY MANAGER • (954) 4333435. GENERAL CONTRACTOR SHALL SECURE AND PAY FOR THE FOLLOWING ITEMS, NECESSARY FOR EXECUTION AND COMPLETION OF THE WORK AND AS APPLICABLE AT THE TIME OF RECEIPT OF BIDS- PERMITS, FEES, LICENSES, BONDS AND NSUIRANCE'S REQUIRED 15Y LOCAL AUTHORITIES AND/OR LANDLORD. REGULATORY AGENCIES: ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDNANCE$ WAVING JURISDICTION, AND N ACCORDANCE WITH THE 'DESIGN CRITERIA FOR TENANT WORK' ISSUED BY THE LANDLORD. REFERENCE STANDARDS: COMPLY WITH THE APPLICABLE SPECIFICATION AND STANDARDS OF UL, ASTM, ANSI, AWI, NEMA, AIA AND ALL OTHER STANDARDS OF MANUFACTURERS ASSOCIATIONS. QUALITY ASSURANCE_ THE CONTRACTOR ASSUMES OVERALL RESPONSIBILITY FOR THE WORK OF THIS PROJECT To ASSURE THAT ALL ASSEMBLES, COMPONENTS AND PARTS NDICATED OR REQUIRED COMPLY WITH CONTRACT DOCUMENTS. ANY SUBSTITUTION MADE BY THE CONTRACTOR WITHOUT PRIOR WRITTEN APPROVAL OF THE OWNER WILL BE REJECTED AND REPLACED AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR A-80 ASSURES THAT ALL COMPONENTS, SPECIFIED OR REQUIRED TO SATISFACTORILY COMPLETE THE INSTALLATION ARE COMPATIBLE WITH EACH OTHER WITH ADJOINING SUBSTRATES, MATERIALS AND WORK BY OTHER TRADES, AND WITH THE CONDITIONS OF INSTALLATION AND EXPECTED USE - FIRE -RATED CONSTRUCTION: WHEREVER A FIRE RESISTANCE CLASSIFICATION IS INDICATED OR REQUIRED FOR CONSTRUCTION, PROVIDE MATERIALS, ACCESSORIES AND APPLICATION PROCEDURES WHICH COMPLY WITH THE REQUIREMENTS OF UL 'FIRE RESISTANCE INDEX' FOR THE IL DESIGN NUMBERS CORRESPONDING WITH THE CONSTRICTION ASSEMBLIES NDICATED. @1030Skm / DAMAGED FREIGHT: NIDCATED BELOW ARE INSTRUCTION ON HOW TO HANDLE SHORT, OR DAMAGED FREIGHT: I. BEFORE SIGNING THE FREIGHT BILL, NOTE SPECIFICALLY THE ITEM(S) DAMAGED OR MISSING Ie., ONE LIGHT FIXTURE, TWO PIECES OF SLATWAL L, ETC. 2. AFTER DAMAGED OR MISSING ITEMS ARE NOTED ON FREIGHT BILL, HAVE CARRIER'S DRIVER ALSO SIGN It. THIS WILL VERIFY THAT BOTH PARTIES AGREE t0 THE EXTENT OF DAMAGE OR SHORT ITEMS. 3. THERE ARE TIMES WHEN DAMAGE IS DISCOVERED ONLY UPON UNPACKING THE FREIGHT. N ORDER TO RECEIVE PAYMENT FROM RiEIGHT COMPANY, WE MUST PROVE THAT THE FREIGHT WAS DELIVERED IN DAMAGED CONDITION. THEREFORE, ALL CARTONS MUST BE INSPECTED FOR SIGNS OF DAMAGE OR ABUSE AND THIS IS TO BE NOTED. 4. PHONE THE TRAFFIC DEPARTMENT N HOFFMAN ESTATES, MITCH TODA (841) 165-4610, AND ADVISE EXTENT OF DAMAGE OR SHORTNESS AND TO RECEIVE DISPOSITION NSTRICTIONIS. 5. SEND A COPY OF THE FREIGHT BILL AND A COPY OF THE ORDER (PROVIDED AT START OF CONSTRUCTION) ALONG WITH ANY OTHER INPOR'4ATN REQUESTED BY MITC 4 t0 CLAIRE'S BOUTIQUES, NO, 2400 WEST CENTRAL. RD, HOFFMAN ESTATES, IL 60195. 6. BE SURE TO CONTACT THE PROJECT MANAGER TO INFORM HIM/HER OF THE LOSS SO THAT, IF NECESSARY, THE ITEMS) CAN BE REORDERED. UNLOADING FDOTRES: INCLUDE N BASE BID, THE COST TO UNLOAD ALL DINER SUPPLIED FIXTURES AND MATERIALS WITH THE EXCEPTION OF ITEMS FROM OUR DISTRIBUTION CENTER N HOR"AN ESTATES. PROTECTION OF MATERIALS / FURNITURE ON SITE: G.C. IS RESPONSIBLE FOR THE SECURITY, CARE AND DAMAGE PREVENTION OF ALL MATERIALS AFTER DELIVERY t0 JOB SITE. G.C. WILL BE BACKCAARGED FOR DAMAGES AND MISSING ITEMS. 01500 EXISTING (CONDITIONS: GENERAL CONTRACTOR IS TO VISIT THE JOB SITE TO INSPECT THE EXISTING CONDITIONS AND TO VERIFY THE AMOUNT OF WORK THAT WILL BE NECESSARY FOR THE PROJECT t0 BE COMPLETED ACCORDING TO THE CONSTRUCTION DOCUMENTS, EXAMINE THE SUBSTRATES AND ADJONNG CONSTRUCTION, AND THE CONDITIONS UNDER WHICH THE WORK IS t0 BE PERFORMIED. DO NOT PROCEED WITH THE WORK UNTIL UNSATISFACTORY CONDITION DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK WAVE BEEN CORRECTED. BEFORE PERFORMING ANY WORK OR ORDERING ANY MATERIAL, THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSION OF ANY EXISTING OR NEW WORK AND SHALL BE RESPONSIBLE FOR THEIR ACCURACY. ANY DIFFERENCES FOUND SHALL BE SUBMITTED t0 THE OWNER FOR CONSIDERATION BEFORE PROCEEDING WITH WORK 01510 TEMPORARY PROTECTION: (BARRICADE) GENERAL CONTRACTOR IS RESPONSIBLE FOR THE ERECTION OF TEMPORARY PROTECTION OF THE CONSTRUCTION N ACCORDANCE WITH THE LANDLORD MQUIMI, ENTS AND LOCAL FIRE CODES. THE CONTRACTOR SHALL PAINT THE STORE LOGO ON THE BARRICADE WALL USING GRAP141C DRAWINGS FURNISHED BY TENANT. C%a t0 COORDINATE GRAPHICS AND PANT COLORS WITH LANDLORD TENANT COORDINATOR 01610 PRODUCT HANDLING: DELIVER AND STORE MATERIALS N SEALED CONTAINERS AND (BINDLES, FULLY IDENTIFIED WITH MANUFACTURER'S NAME, BRAND, TYPE AND GRADE- PROTECT METERIALS FROM CORROSION AND DAMAGE STORE N A DRY VENTILATED SPACE, OFF THE GROUND. COORDINATE ALL DEL.IVMES WITH( THE MALL LANDLORD AND TENANT SUPPLIED MATERIAL VENDORS. GENERAL CONTRACTOR WILL RECEIVE AND UNLOAD ALL FIXTURES FROM THE FIXTUMRE SUPPLIER ACCORDING TO THE TERMS AND CONDITIONS IMPOSED BY THE MALL DEVELOPER I.E. SPECIAL TIMES t0 UNLOAD, ETC. FIXTURES t0 BE SET BY GENERAL CONTRACTOR GENERAL CONTRACTOR WILL NOTIFY TENANT IMMEDIATELY OF ANY MISSING OR DAMAGED ITEMS THAT TENANT SUPPLIES AND GYRAL CONTRACTOR INSTALLS. HE WILL OBTAIN AND FILL ALL NECESSARY PAPERWOW, REQUIRED N ORDER TO FACILITATE TENANT IN HIS ABILITY TO PROPERLY FILE CLAIM FOR DAMAGES OR LOSSES. REFER t0 TENANT SHORTAGE/DAMAGED GOODS POLICY INCLUDED N BID INSTRUCTIONS FROM TENANT. 0110 CLEANING/ADJUSTNGA'MA ES: EXECUTE FEIRIODIC CLEANING DURING PROCESS OF WORK, AND OFT WORK SO THATHE ALL FINISHED SURFACES ARE- FREE OF ANYT F� ETION MATERIAL. CONDUCT CLEANING AND DISPOSAL OPERATIONS TO COMPLY WITH CODES, ORDINANCES, REGULATIONS, ANTI -POLLUTION LAWS AND LANDLORD REQUIREMENTS. REMOVE GRE SE, MASTIC, ADHESIVES, DIRT, STAINS, LABELS AND OTHER FOREIGN MATERIALS FROM SIG#1T EXPOSED SURFACES. GENERAL. CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM JOBSITE, ON A DAILY BASIS. PROTECTION: PROTECT AND MAINTAN ALL WORK THROUGHOUT CONSTRUCTION SO THAT IT WILL BE FREE OF DAMAGE At THE TIME OF ACCEPTANCE BY THE TENANT. COMPLETION: STORE t0 BE READY FOR OCCUPANCY - ALL SURFACES CLEAN. 01100 CLEMWAPA TNG/MA IES PART I -ORAL A FINAL CLEANNG I. GENERAL CONTRACTOR t0 PROVIDE A PROFESSIONAL CLEANING SERVICE t0 EXECUTE FINAL CLEANING PRIOR TO B. ADJUSTING I. ADJUST OPERATING PRODLICTS AND EQUIPMENT TO ENSURE TURN( -OVER C. SPARE PARTS AND MAINTENANCE PRODUCTS 1. PROVIDE SPARE PARTS, MAINTENANCE, AND EXTRA SMOOTH AND UNHINDERED OPERATION. D. OPERATION AND MAINTENANCE DATA 1. SUBMIT DATA BOUND N 8-1/2x11 NCH TEXT PAGES, tH1REE D PRODUCTS N QUANTITIES SPECIFIED N INDIVIDUAL SPECIFICATION SECTION. 2. PREPARE BINDER COVER WITH PRINTED TITLE 'OPERATION AND MAINTENANCE INSTRUCTIONS', TITLE OF PROJECT. SIDE RNG BINDER WITH DURABLE PLASTIC COVERS. E. WARRANTIES AND BONDS I. EXECUTE AND ASSEMBLE TRANSFEIRAME WARRANTY DOCUMENTS FROM SUB -CONTRACTORS, SUPPLIERS, AND MANUFACTURERS. PART 2 - PREPARATION / EXECUTION A FINIAL CLEANING I. CLEAN INTERIOR AND EXTERIOR GLASS, SURFACES EXPOSED TO VIEWt REMOVE TEMPORARY LABELS, STAINS AND FOREIGN SUBSTANCES, POLISH TRANSPARENT AND GLOSSY SURFACES, VACUUM CARPETED AND SOFT SURFACES. 2. CLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH CLEANING MATERIALS APPROPRIATE TO THE SURFACE AND MATERIAL BEING CLEANED. 3. REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH AND CONSTRUCTION FACILITIES FROM THE SITE. i AND ALL DEMOLITION REQUIRED TO COMPLETE CONSTRUCT"ON FOR THI 1�ly. ACT AND SHOULD BE IN ACCORDANCE WIN T14E LANDLORDS REQUIREMENTS. THE TRICTIoN DOCUMENTS INDICATED EXISTING CONDITIONS, WALLS, A AS TO BUT THE ARCHITECT DOES NOT CERTIFY THAT ALL DEMOLITION IS INDICA ON THE PLANS. ANY ITEMS INDICATED AS pcIStING, To REMIA HAVE TO BE CtEp BY THE GENERAL CONTRACTOR TO DETE141M F OF THESE ITEMS BE REUSED. AT THE END OF CONSTRUCTION, THE T14G WALLS, ARS 6 G, SHOULD BE LIKE -NEW CONSTRUCTION - ALL DETMIOLI WORK SMALL BE REMOVED FROM THE PROJECT AND LEGALLY DI OF No CONSTRUCTION MATERIALS ARE TO DISPOSED OF N tW MALL RECEPTACLES OR DIMIPSTERS WITHIOUT LORD'S PRIOR ,APPROVAL.. ISR DEMOLITION PLAN NOTES. I. SCOPE: FURNISH I"IM AND PERFORM LABOR TO EXECUTE THIS WORK AS NDICA ON THE DRAWINGS AS SPECIFI AND AS NECESSARY TO COMPLETE THE , INCLUDING, BUT NOT LIM TO, THESE MAJOR ITEMS. A PROTECTION OF EXIS WORK TO F431AK B. DEMOLISH EXISTING TRUCTION WHERE ICATED ON THE DRAWINGS AND REQUIRED B JOB CONDITIONS. C. REMOVAL OF PARTITIONS, , FL COVERINGS, AND CEILINGS, D. REMOVAL AND CAPPING OF ME ICAL AND ELECTRICAL FIXTURES AND SERVICES. E DEBRIS REMOVAL AND DI R REMOVAL OR CORING OF IONS EXISTING CONCRETE SLAB AS REQURED FOR SERVICE EQUI INSTALLATION. PATC14NG SHALL BE AccEPTABLE O THE PONT T THE FINISH WILL ACCEPT SCHEDULED FINISH MA WITH NO EFFEC I OF AN ALTERATION HAVING MADE. G. REMOVAL OF ANY STNS STOFVR�ONT, NCL ING OVERHEAD ROLL -UP GRILLE. 2. GENERAL REQUI S A THE ORS SHALL BE FULLY RESPONSIBLE THE ADEQUACY AND NST TION OF ALL TEMPORARY SHORING SYS USED DURING THE OF ALL STRUCTURAL ELEMENTS. B. THE DO NOT NECESSARILY NDICATE THE FILL OF THE REQUIRED t0 BE PERFORMED. INSPECT THE EXIS1k4G TRJCt101 Y t0 DETERMINE THE RILL EXTENT OF WIORIK t0 BE THE PROBLEMS INVIOLVED. NO EXTRA COMIPENSATION WILL OIUED BECAUSE OF FAILURE TO ESTIMATE TME FULL EXTENT OF HE OR FOR ANY CONTINGENCY ALLOWANCES. . ALL WORK SHALL BE PERFORMED BY SKILLED AND PROPERLY EQUI C FERSON EL DEMOLITION AND F610YAL OF ITS ITi`MS SCAFFOLD WIGW HIGHER SHALL BE LOWERED BY CONTROLLED METHIODS, NOT BY THROWING OR DROR'ING PERFORM CUTTING AND STRPPM SO THAT THE WORK TO REMAIN IS UNDAMAGED AND N SUCH A MEANER THAT NEW WORK CAN BE PROPERLY BE CONNECTED WITH IT. D. UNFORESEEN CONDITIONS: INCLUDE N THE BASE BID MISCELLANEOUS CUTTING AND PATCHNGs NECESSITATED AS A RESULT OF UNFORESEEN CONDITIONS AND THE REWORKING OF ABUTTING; SURFACES AS REQUI TO NEW WORK JON AND MATCH EXISTING SURFACES t0 REMAIN. ftTRA PAYMENTS BASED ON THE PLEA OF UNFORESEEN CONDITI WILL E. G C t0 NATE WITH THE LANDLORD ALL WORK THAT AY ELECT NORMAL ILY OPERATIONS OF THE LANDLORD PREM( AND COMPLY WITH ALL TRICTIONS THE LANDLORD MAY HAVE OLITION AND/ ION SCHEDULES. COOPERATE TO THE END THAT CERTAN FACIL S AND SERVICES ARE MAINTA N OPERATION UNTIL IMMEDIATELY THEIR REMOVAL IS REQUI TO PERMIT INSTALLATION OF WORK F. NOISE CONTROL: C ON ALL WORK N MANNER WHICH WILL PRODUCE THE LEAST AMOUNT OF NO INSTRUCT L WORKERS N NOISE CONTROL. PROCEDURES. 3. PROTECTION OF PERSONNEL- ERE GN, BARRICADES AND SUCH OTHER FORMS OF WARNING AS MAY BE M D t0 PREVENT PERSONNEL FROM PUTTING THEMSELVES N THE WAY 4. MECHANICAL, ELECTRICAL, PLUMBING A CARL3dLLY REVIEW S AND DETERh11NE L S TO BE REMOVED AND THOSETO BE KEPT TIVE OR TO BE REACTIV . PROTECT LINES t0 REMAIN. PROVI FOR MINK" SERVICE WE ION OF LINES t0 REMAIN. B. REMOVE S COMPLETELY WHENEVER POSSIBLE. CUT CAP OR PLUG TO PRE ESCAPE OF GAS, LIQUID, ETC- BEHIND THE OF THE FINISH ATERIAL. C AIR REPLACE, OR MAKE GOOD DAMAGE to EXISTNG CONS TION ICH OCCURS AS A RESULT OF DEMOLITION OPERATION, At NO ADDITIONAL C46T t0 CSI, THE ARCHITECT OR THE LANDLORD. THE LANDLORD. THESE REPAIRSSHALL NC -UDE ANY ROOF PATCHING REQUIRED DIE TO DEMOLITION AND SHALLCOORDINATED WITH LANDL AND LANDLORD'S ROOFING CONTRACTOR 03010 CONCRETE= WHEN THE CONCRETE FLOOR SLAB IS EXISTING, PREPARE THE SLAB TO RECEIVE FINISH AS NDICATED ON THE PLANS. WHEN ON A GROUND FLOOR LOCATION, THE CONCRETE SLAB FLOOR SHALL BE SEALED N THE AREAS t0 RECEIVE CARPETING. WHEN SLAB FLOOR 18 TO BE EXECUTED AS PART OF THE CONTRACT, FOLLOW LANDLORD'S DIRECTIONS AND SPECIFICATION. GE!T ERAL TOR SHALL INSPECT THE EXISTING SLAB TO DETERMINE THE FLOOR SLAB T VED AND REPLACED FOR NSTALLATI Cm ,M IC AND PLUMBNG WORK AND STEEL COLUMNS FOR GRILLE ALL CONCRETE REFILLING, AS WE AND ALL PENETRATIONS SLAB, SHALL BE EXECUTED IN WITH THE 05010 STRUCTURAL METALS: THE DESIGN, FABRICATION AND INSTALLATION OF ALL MISCELLANEOUS METAL LINTELS, SUPPORTS AND FRAMNCs REQUIRED FOR ALL STORE FRONT WOW SHALL BE THE SOLE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR 06100 ROU.IC44 CARPENTFM ALL WOOD FRAMEWORK, WOOD BLOCKING AND PLYWOOD CONSTRUCTION SMALL BE FIRE RETARDANT TREATED AS REQUIRED BY LOCAL CODES AND LANDLORD REQUIREMENTS. PARTICLE BOARD SHALL BE UL CLASS 1 FIRE -RATED, SANDED AND PREPARED TO RECEIVE PLASTIC LAMINATE OR PANTED METAL LAMINATE. WOOD FRAMING MEMBERS SHALL BE No.1 LIGHT FRAMNG DOUGLAS FIR OR NO.2 OR BETTER YELLOW PINE OF THE OMENIONS INDICATED ON THE PLANS. PLYWOOD SHALL BE GRADE B -D DOUGLAS FIR SANDED AND PREPARED YO RECEIVE PLASTIC LAMINATE, METAL LAMNIATE OR PAINT. PLYWOOD BACKING PANELS FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT SHOULD BE FIRE RETARDANT TREATED PLYWOOD WITH GRADE DESIGNATION, APA C -D PLUGGED INT. NOT LESS THAN 3/4' THICK. PROVIDE FASTENERS AND ANCHORAGE OF THE TYPE, SIZE, MATERIAL AND FINISH AS RECOMMENDED BY APPLICABLE STANDARDS, COMPLYNG WITH1 APPLICABLE FEDERAL SPECIFICATIONS FOR NAILS, STAPLES, SCREWS, BOLTS, NUTS, WASHERS AND ANCHORING DEVICES. PROVIDE BLOCKING AS REQUIRED FOR INSTALLATION OF SHELVING, EQUIPMENT, ACCESSORIES, FIXTURES, AND FINISH HARDWARE OR OTHER HEAVY ITEMS ON WALLS. 06400 ARCHIITE FINISHED WOODS SHALL BE OF THE TYPE SPECIFIED N THE PLANS AND SHOULD COMPLY WITH PREMIUM( GRADE WORK AS DESCRIBED N 'ARCHITECTURAL WOODWORK QUALITY STANDARDS' PUBLISHED BY THE ARCHITECTURAL WOODWORD INSTITUTE. THE WOOD SHALL BE STRAIGHT AND FREE OF BLEMISHES AND OF SUFFICIENT LENGTH TO PERMIT A MINIMUM N 15ER OF JOINTS. CONDITION WOODWORK t0 PREVAILING HUMIDITY CONDITION N INSTALLATION AREAS PRIOR t0 INSTALLING INSTALL WOODWORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. $NIM AS REQUIRED USNG CONCEALED SHMS. INSTALL t0 A TOLERANCE OF 1/8' IN V-0' FOR PLUMB AND LEVEL AND WITH NO VARIATION N FLUSHNESS OF ADJOINING SURFACES. ANCHOR WOODWORK TO ANCHORS, OR BLOCKING BUILT -N, OR DIRECTLY ATTACHED TO SUBSTRATE. SECURE WITH CONCEALED FASTENERS. ALL SURFACES SHALL BE SANDED TO A SMOOTH SURFACE, READY FOR STAINING OR FINISH PANTING AS PER DETAILS AND SCHEDULES. 06410 HARDU1AM:___ HARDWARE SHALL BE OF THE TYPE, FINISH AND MANUFACTURER SHOWN. MANUFACTURERS KERS CATALOG NUM MIRE USED HEREIN ARE INTENDED TO INDICATE THE QUALITY REQUIRED. ALTERNATE MANUFACTURERS AND PRODUCTS MAY BE SUBMITTED t0 THE TENANT FOR SUBSTITUTION APPROVAL. NO OTHERS SHALL BE ACCEPTABLE. FURNISH HARDWARE TEMPLATES N A TIMELY MANNER TO THE VARJOUS AFFECTED TRADES FOR COORDINATION OF THEIR WORK 01900 SEALANT: PART 1 -ORAL A EXPANSION JOINT MATERIAL, SEALANTS AND JOINT BACKING FOR JOINTS BETWEEN DISSIMILAR MATERIALS. I. SILICONE SEALANTS (TYPE SA ASTM C920, SINGLE COMPONENT, NON -SAGGING, NON -STAINING, NON-BLEEDINGt FOR USE AS GENERAL CAULKINGt COLOR TO MATCH ADJACENT SURFACES, MANUFACTURER BY GE SILICONES OR EQUAL. 2. JOINT BACKNG: ROUND, OPEN CELL POLYETHYLENE FOAM ROD. PART 2 - PREPARATION / EXECUTION A REMOVE LOOSE MATERIALS AND FOREIGN MATTER WHICH MIGHT IMPAIR ADHESION OF SEALANT. B. CLEAN AND PRIM JOINTS N ACCORDANCE WITH MANUFACTURER'S INTRICTIONS. C. PROTECT ELEMENTS SURROUNDING THE WORK OF THIS SECTION FROM DAMAGE OR DISFIGURATION. D. INSTALL SEALANT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, E. INSTALL JOINT BACKING. F. APPLY SEALANT WITHIN RECOMMENDED APPLICATION TEMPERATURE RANGES. CONSULT MANUFACTURER WHEN SEALANT CANNOT BE APPLIED WITHIN THESE TEMPERATURE RANGES. 08210 WOOD DOORS: ALL INTERIOR WOOD DOORS SMALL M SOLID LUMBER CORE (COORDINATE WITH DOOR SCHEDULE) FLUSH CONSTRUCTION, OF THE DIMENSIONS SHOWN, AND SHALL MEET OR EXCEED THE AN8144" INDUSTRY STANDARD I,SJSERIES AND AWI QUALITY STANDARD FOR ARCHITECTURAL. FLUSH DOORS. DOORSKN FOR PAINTED AND VNYL COVERED SURFACES SMALL BE OF PAINT GRADE. OVERALL THICKNESS OF DOOR" SHALL BE 1/8' AND SHOULD BE BELT SANDED FOR PANT FNISK FNAL SANDING BY FIELD FINISHER WHEN REQUIRED BY CODE, FIRE DOORS SHOULD HAVE THE REQUIRED FIRE RATING. WOOD FRAME& EXAMINE DOOR FRAMES AND VERIFY THAT THE FRAMES ARE THE CORRECT TYPE AND HAVE BEEN INSTALLED AS REQUIRED FOR PROPER HANGING OF CORRESPONDING DOORS ALIGN AND Flt THE DOORS N THE FRAMES WITH THE FOLLOWING UNFORM CLEARANCES AND BEVELS. TRIM STILES AND RAILS ONLY TO THE EXTENT PERMITTED BY LABELING AGENCY. FOR NON -RATED DOORS, PROVIDE CLEARANCES OF 1/8' AT JAMBS AND HEADS, AND i/8' FROM THE BOTTOM OF THE DOOR TO THE TOP OF THE FINISH OR COVERING FOR FIRE -RATED Poo", PROVIDE CLEARANCES AND GORMOPCNDws FIRE -RATED FRAMES N ACCORDANCE WITH REQUIREMENTS OF NWA NO.80 EXISTING DOORS- WHEN OOR&WHEN EXISTING DOOR IS TO REMAIN N SERVICE, DOOR AND FRAME MUST BE RAISED 3/8' FROM EXISTING FLOOR t0 PROVIDE FOR DOOR CLEARANCE IF OVER STORE LLE(S) WILL BE SUPKIED BY TENANT AND NtXAMEP BY THE GRILLE GRILLES ARE TO BE SELF- BUT ARE ATTACHED t0 THE MAL RE ABOVE FOR SUPPORT ONLY. GENERAL CONTRACTOR IS t0 NATE CONNECTIONS WITH APPLICABLE LANDLORD CRITERIA APPROVALS. ORAL CONTRACTOR IS TO TEL OUT' THE STORERaONT(S) FOR THE GRILLE CONTRACT RING GRILLE Ct74T (S) AND SUPPORT LOCATIONS. RELEASE E COMPONENTS TO BE INSTALLED N TENANTS' BEN OSURE LINE N COMPLIANCE WITH GRILLE MANUFACTURER'S CFICATION AND CONSTRUCTION DOCUMENTS. PART I - GENERAL A FURNISH AND INSTALL FINISH HARDWARE FOR NTEMOR AND EXTERIOR DOORS AND ROLLING GRILLES. B. SEE DOOR SCHEDULE FOR SPECIFIC ITEMS, MANUFACTURERS AND MODEL NUMBERS. TEMPLATES SHALL RBE FURNIISHED FOR USE N FIELD. C. FOLLOW PHI (DOOR AND HARDWARE INSTITUTE) STANDARDS AND GUIDELINES AND AM (AMERICAN WOODWORKING INSTITUTE) STANDARDS FOR HARDWARE INSTALLED ON WOOD DOORS. D. PJRNISW OWNER WITH MAINTENANCE DATA, MAINTENANCE PROCEDURES, MANFACTLRERS WARRANTIES AND SPECIAL TOOLS. E. FINISHES. PER HAR411)4RE SCHEDULE F. KEYING I. ORAL CONTRACTOR TO COORDINATE KEYING AND MASTER KEYING WITH CONSTRUCTION MANAGER 2. GENERAL CONTRACTOR TO INSTALL CONSTRUCTION CORES DURING CONSTRJCTIO4 AND REPLACE WITH PE14i4ENT AT END OF JOB PRIOR t0 TURN -OVER G. PROVIDE COMMERCIAL GRADE HARDWARE, COMIPLYNG WITH PROJECT SPECIFICATIONS, N SETS ACCORDING TO THE SCHEDULE HEREIN AND ON DOOR SCHEDULE DRAWING. REFER TO DOOR SCHEDULE HARDWARE PART 2 - PREPARATION / EXECUTION A. COORDINATE THE WORK WITH OTHER DIRECTLY AFFECTED SECTIONS INVOLVNG FABRICATION OF WALL INTERNAL REINFORCEMENT FOR DOOR HARDWARE AND RECESSED ITEMS. B. VERIFY THAT DOORS AND FRAMES ARE READY TO RECEIVE WORK AND DIMENSION ARE AS INDICATED. C INSTALL HARDWARE N ACCORDANCE WITH MANUFACTURER'S NSTRIJCTIONS. D. USE TEMPLATES PROVIDED BY HARDWARE ITEM MANUFACTURER E, WHEREVER CUTTING AND FITTING IS REQUIRED t0 INSTALL HARDWARE ONTO OR INTO SURFACES W14104 ARE LATER TO BE PAINTED OR OTHERWISE FINISHED, INSTALL EACH ITEM COMPLETELY, THEN( REMOVE AND STORE DURING APPLICATION OF FINISHES. REINSTALL UPON COMM°LETION OF FNISHNG OPERATIONS. SPACE FASTENERS AND ANCHORAGES AS INDICATED OR N ACCORDANCE WITH FACTORY STANDARDS. F. ADJUST HARDWARE FOR SMOOTH OPERATION. 0_8800 GLASS AND GLAZNG• PROVIDE GLASS AND GLAZING; AS SHOWN, AS MANIFAC1UMb BY HGP, OR APPROVED EQUAL PRODUCTS BY OTHER MANUFACTURERS. COMPLY WITH RECOMMENDATION OF FLAT GLASS MARKETING ASSOCIATICN (F{MA) 'GLAZING MANUAL' AND 'SEALANT MANJAL' EXCEPT WHERE MOM STRINGENT REQUIMMENTS ARE INDICATED. PROVIDE MATERIALS OBTAINED FROM ONE SOURCE FOR EACH TYPE OF GLASS AND GLAZING PRODUCT INDICATED. PROVIDE GLASS DOORS AS SHOWN, AS MANUFACTURED BY HGP, OR APPROVED EQUAL PRODUCTS BY OTHER MANUFACTURERS. DOORS SHALL BE HGP STYLE 'P' FULL WIDTH BOTTOM AND TOP RAILS. DOORS SHALL BE FACTORY ASSE15LED AND PREPARED t0 ACCOMMODATE PUSH -PULLS AND LOCK CYLINDERS INSTALLED BY or. PUSH -PULLS SHALL BE HGP STYLE HIB -1,10' OR APPROVED EQUAL. ALL GLASS DOOR HARDWARE FINISHES SMALL BE HGP +335 BLACK ANODIZED OR APPROVED EQUAL. WHERE SAFETY GLASS IS INDICATED OR REQUIRED BY AUTHORITIES 1 AVNG JURISDICTION, PROVIDE TYPE OF PRODUCTS WHICH COMPLY WITH ANSI 2911. MIRROR SHALL COMPLY WITH F.S. DD-G-411C,TYPE I, CLASS I, QUALITY Q2,1/4' THICK PROVIDE SILVERING, COPPER 13ACKNG AND PROTECTIVE COATING coWORMIING TO F.S. DD -11.411. FABRICATE GLASS t0 812E8 REQUIRED FOR GLAZING OPENINGS WITH EDGE CLEARANCE AND TOLERANCES COMPLYING WITH RECOMMENDATIONS OF GLASS MANUFACTURER ALL GLASS AND MIRRORS TO HAVE EXPOSED EDGES WILL BE GROUND AND POLISHED. 09250 GYPSUM DRYWALL SYSTEMS: PFtMPE ALL GYMIM DRYWALL MATERIALS THROUGHOUT THE WORK PRODUCED BY ONE MANFACTURER PROVIDE METAL STUDS AND FRAMING MEMBERS OF TYPES, GAUGES, SIXES AND CORROSIVE RESISTIVE TREATMENTS AS S 401K STUDS AND FRAMING: ROLL FORMED CHANNEL STUDS AND RUNNERS: ASTM C-645, FABRICATED OF GALVANIZED STEEL PER ASTM HATH FLANGES NOT LESS THAN 11/4' OF THE SIZES AND GAUGES SHOUR METAL FURRING CHANNEL& HAT SHAPED, 1/8' HIGH, 25 GAUGE GALVANIZED. BACKER PLATES: 20 GAUGE GALVANIZED. HANGER WIRE: GALVANIZED, SOFT TEMPER STEEL WIRE, SIZED N ACCORDANCE WITH ASTM C-154. MANGER ANCHORAGE: PROVIDE CONCRETE INSERTS, CLIPS, BOLTS, SCREWS AND OTHER DEVICES APPLICABLE TO THE NDICATED METHOD OF STRUCTURAL ANCHORAGE FOR CEILING HANGERS. FURRING ANCHORAGE'S: 16 GAUGE GALVANIZED WIRE TIES, MANUFACTURER'S STANDARD WIRE-TYPE CLIPS, BOLTS, NAILS OR SCREWS, IN ACCORDANCE WITH ASTM C-154 METAL TO METAL UT14N THE DRY TALL SYSTEM: 3/8' TYPE 'S' OR 6-12, PAN HEAD. ADHESIVES: AS RECOMMENDED BY THE GYPSUM BOARD MANUFACTURER TRIM ACCESSORIE& PROVIDE TRIM ACCESSORIES OF THE SIZES REQUIRED FOR THE DRYWALL APPLICATIONS SHOUN SPECIFIED, FABRICATED FROM GALVANIZED STEEL, AND OF THE FOLLOWING TYPE: PROVIDE DRYWALL MOULDING OF THE TYPE AND SIZE INDICATED. PROVIDE METAL CORNER BEAD AT EXTERNAL CORERS WITH SMOOTH RIGID NOSE AND PERFORATED AND KNURLED FLANGES. CONCEAL FLANGES WITH At LEAST 2 COATS OF JOINT COMPOUND FEATHERED OUT APPROXIMATELY 9' ON BOTH SIDES OF THE EXPOSED METAL WHERE DRYWALL ABUTS OR INTERSECTS DISSIMILAR CONSTRUCTION, PROVIDE SQUARE EDGE SEMI -FINISHING CASING BEAD (NO JOINT COMPOUND TREATMENT NECESSARY). TAPE AND JOINT MATERIAL SHALL BE AP'P'LIED TO THE JOINTS. THE JOINT COMPOUND SHALL BE SMOOT1ED OUT APROXIMATLEY 4' WIDE. T14I8 IS t0 BE N THE NORMAL TWj; EE -COAT PROCESS, ALLOWING; 24 HOURS DRYING TIME BETWEEN COATS. ALL NAILS, SCREWS, HEADS OR DIMPLES SMALL ALSO RECEIVE A THREE -COAT FINISH USING THE SAME MATERIAL AND MAMER AS THAT FOR THE JONTS. SAND SMOOTH ALL JOINTS AND SURFACES AND HAVE THEM( READY TO RECEIVE THE WALL FINISH. VERIFY THAT THE EXISTING WALL SURFACES, IF ANY, ARE SMOOTH AND BWTABLE, AS A SUBSTRATE FOR THE FINISHES SCHEDULED. GYPSUM BOARD: 5/8' THICK UNLESS NOTED OTHERWISE. ASTM C36, TAPERED EDGE$. PROVIDE 'TYPE X' (FIRE RETARDANT) WHERE SHOWN AND At DEMISING WALLS. WATER RESISTANT GYPSUM BOARD (GREENIBOARD) ASTM C-630 TYPE V. PROVIDE FOR WET WALLS N TOILETS. USE 'DURLOCK' BE14ND ALL CERAMIC TILE AND MARBLE ON WALLS. drawn by: PH STAFF date: 4/23/04 sheet no: S P arch. project, 04-153-1 • ASTERISK INDICATES NO REVISION MADE TO THIS SHEET E P a E E r E E V i to W z ry u.t z O zp U tY Lli O �V 00 Q z Q 0 N � . v! U Q z . Z drawn by: PH STAFF date: 4/23/04 sheet no: S P arch. project, 04-153-1 • ASTERISK INDICATES NO REVISION MADE TO THIS SHEET E P a E E r E E V W ry O Lli O �V 00 Q z Q 0 N � . v! U Q z . Z wi— LJJ J O Z =P Lu W 0 —� Q Q IZ U V V drawn by: PH STAFF date: 4/23/04 sheet no: S P arch. project, 04-153-1 • ASTERISK INDICATES NO REVISION MADE TO THIS SHEET E P a E E r E E SECTION I -PRODUCTS tl CERAMIC TILE SHALL BE OF STANDARD GRADE QUALITY AS MAMFA►CnMD BY DIEGO COMPANYOF SPAIN, AND NFO. BELOW TILE, SHALL Ca4FOF�M) TO ID $EMENTS OF ANSY BUDGET IEA137a 1988 COMPANY 8llDCiET TILE CO. 1190 NL POIERL.INE ROAD, BAY 5 POPANO W-AC41, FLORIDA 33069 TYPE= CERAMIC TILE SHALL BE ( IMOLA SIZE: CERAMIC TILE SHALL BE MANUFACTURED TO SPECIFIC SIZE AFTER FIRING AND SHALL BE NOMINAL 12'X 12'x 5/16' THICOESS= CERAMIC TILE SHALL BE MANUFACTURED To SPECIFIC TNICKMSS AFTER FIRING AND SHALL BE NOMINAL 80 MM COLOR= CERAMIC TILE SMALL BE FURNISHED N ALMOND. t2 SETTING MATERIALS= USE APPROPRIATE INSTALLATION MORTARS ACCORDING TO ANSI A118. SERIES OR At96JM TYPE L 13 GROUTING MATERIALS= SELECT GROUT PER ANSI A1183, AII85, A118A OR AII88- SW. pOLYBLEND NON -SANDED GROUT. MANUF. = MAPEI. COLOR 'B BONE. 14 WATERPROOFNG/ANTI-FRACTURE Mme: SELECT PER ANSI AIIS10-1993 AS REQUIRED. 13 GROUT SEALER BONSAL OR EC ml - SECTION 2-NSTALLATION 2.1 ACCEPTABILITY OF SURFACES A, BEFORE TILING, VERIFY THAT ALL SURIFACES t0 BE TILED ARE STRUCTURALLY SOUND TRUE To PLANE, AND FALL WT14IN MAXIMUM VARIATIONS SNOUN BELOW: WALLS FLOORS WNW I/8'IN10' REPORT ALL W,ACCEPTABLE SURFACES t0 ll -E APrA4ITEC7r N WRITING, AND DO NOT TILE SUCH SURFACES UNTIL THEY ARE LEVELED ENO -44 TO MEET ABOVE REQUIREMENTS. B BEFORE TILING, ALL SURFACES MUST BE FREE OF CURING COMIPOUNDS, OIL, GREASE, WAX, DIRT, DUST, FORM RELEASES OR OTHER SUBSTAN M6 THAT WOULD INTERFERE WITH PROPER BOND OF SE=TTING MATERIALS. IF TILE IS INSTALLED BY TME THIN -SEI' METHOD, CONCRETE SLABS SMALL BE STEEL ?ROWEL OR LIGHT BROOM FINISH. 2.2 SETTING METHODS= COMPLY UAT14 APPROPRIATE ANSI AI08 SPECIFICATION CURRENT AND TILE COUNCIL OF AMERICA HANDBOOK FOR APPROPRIATE METHOD OF INSTALLATION FOR EACH SPECIFICATION. FOR ADHESIVE MORTAR APPLICATION USE FOLLOWING= UMT14 FLAT SIDE OF TROLL, KEY MORTAR NTO SUBSTRATE USING THE APPROPRIATE SIZE TROUEL, COMB MORTAR IN ONE DIRECTION U AT14 NOTCHED SIDE OF TROIEL SET TILE WITH A SLIDING MOTION, PERPENDICULAR TO THE MORTAR RIDGES. OBTAIN AS NEAR AS 100x COVERAGE AS POSSIBLE OF MORTAR TO TILE. MORTARR MUST BE SUFFICIENTLY DISTRIBUTED To GIVE FULL SUPPORT UNDER ALL CORNERS AND EDGES OF THE TILE. PERIODICALLY, REMOVE SHEETS OR NOMDUAL TILES TO ASSURE PROPER BOND COVERAGE CONSISTENT WITH INDUSTRY SPECIFICATIONS 23 MAX. GROUT JOINT - W. 2.4 EXPANSION JOINTS: INSTALL ARCHITECTURALLY DESIGNED EXPANSION JONTS AS PER CURRENT ICA DETAIL EXIL PREFABRICATED EXPANSION JOINT STRIPS CAN ALSO BE USED WHEN SUITABLE. 25 GROUTING METHODS: FOLLOW EXACTLY GROUT MANUFACTURES INSTRUCTIONS AND COMPLY WITH APPROPRIATE ANSI AWS SPECIFICATION DEPENDING ON TYPE OF GROUT SELECTED. GROUTING IS NOT COMPLETE UNTIL ALL GROUT HAZE AND RESIDUES ARE RN MOVED FROM THE SURFACE OF THE TILE 2b GROUT SEALAR- COMPLY WITH MANUFACTURES INSTRUCTIONS AND APPROPRIATE ANSI SMECIFIC.AtION18 FOR PRODUCT SELECTED. 21 CLEANNG AND PROTECTION A. LEAVE FINISHED INSTALLATION FREE OF CRACKED, CHIPPED, BROKEN, UNBOWED OR OTHERWISE DEFECTIVE TILE WORK S. PROTECT ALL FLOOR TILE NSTALLATIONIS WITH CLEAN CONSTRUCTION PAPER OP- OTHER ROTHER HEAVY C rvSRNG DURING CONSTRUCTION PERIOD TO PREVENT STAINING OR DAMAGE. No FOOT OR WHEEL TRAFFIC PERMITTED ON FLOOR FOR AT LEAST THREE (3) DAYS AFTER GROUTING. 1/2' D149Z AS MANUFACTURED BY UNITED STATES GYPSUM CO, OR EQUAL. MEMBERS SHOULD BE STRAIGHT, TRUE, INFORM DP..-..TeAv�D FRAMNG PROPERLY ALIGNED. ALL SURFACES TOROCK IS FASTENED SHALL E AND CLEAR OF ANY PROTRUSI WHICH WOULD CAUSE THE PANEL t0 BE FLE THE LINE OF T14E INSTALL ALU. MATERIALS PER MAJNUFAGTU CIFICATI RECOMI"ENDATIONS. JONT REINFORCEMENT: DUROC:IGR TYPE 'P' TAPE. FASTENERS= SCREWS AND PER MANUFACTURERS RECCMI" ENDO METALS MUST BE 20 GA. OR 14EAVIER • NO MORE THAN 16' OIC- 1 U4' S-12 FLAT R HEAD SCREWS WITH COUNTERSINKING RBS AND CLMASEAL SCIMM MAY BE PLACED A MAX. OF 8' APART. 09511 ACOUSTICAL I AY -N CEILING PROVIDE ACOUSTICAL LAY -N CEILNG AS SHOWN AND SPECIFIED THEREIN. WHERE CEILINGS ARE REQUIRED t0 COMPLY WITH A FIRE HAZARD CLASSIFICATION FOR FLAMESPREAD AND SMOKE DEVELOPMENT, PROVIDE TILES WHICH HAVE BEEN TESTED, RATED AND LABELED BY LL FOR THE REQUIRED RATINGS. PROVIDE TILES AND SUSPENSION SYSTEM MEETING THE REQUIREMENTS OF THE NATIONAL FIRE PROTECTION ASSOCIATION 901 AND ASTM C 635, AS APPLICABLE PROVIDE FACTORY FINISHED UNITS OF THE COMPOSITION, PATTERN, FINISHES, SIZES, THICKNESS AND END PROFILES AS INDICATED N THE PLANS AND THIS SPECIFICATION. ACOUSTICAL CEILING SYSTEMS SHALL BE EQUAL t0 THAT MArNFACTURED BY ARMSTRONG WORLD INDUSTRIES, AS INDICATED ON THE FINISH SCHEDULE. RUNNER, CROSS F4" ERS AND EDGE MOLDINGS: It WILL BE A DIRECt-WING NTERMEDIATE-DUTY SUSPENSION SYSTEM WITH EXPOSED MOLDINGS FOR SUPPORT AT EDGES OF CEILING, AT WALLS AND COLUMNS, WITH A SINGLE FLANGE OF MOLDING EXPOSED. PROVIDE UNIFORM FACTORY APPLIED FNI814 ON EXPOSED DACE COLOR t0 MATCH CEILING TILE. SUSPENSION SYSTEM: HANGER WIRE= GALVANIZED CARBON STEEL WIRE, ASTM A 641, SOFT TEMPER, PRE -STRETCHED, CLASS 1 COATING. NOT LESS THAN 12 GAUGE. TILES: RIGID BOARD O' MINERAL FIBER WET -FELTED WITH STANDARD DENSITY PANELS, MINIMUM 10 LBS. PER CSI. FT. PATTERN SIMILAR TO ARMSTRONG WORLD INDUSTRIES, INC. 'FISSURED', 24' X 48' X 5/89, OR 24' X 24' X 5/8', MANUFACTURER'S STANDARD WASHABLE WHITE PANTED FINISH. ALL 24' X 24' TILE SHALL HAVE TEGULAR EDGE, UNLESS NOTED OTHERWISE ON REFLECTED CEILING PLAN. 05650 RESILIENT FLOORING AND BASE: PROVIDE TILE UNITS OF THE COLOR, SIZE AND MANUFACTURER SHOWN. PRIOR t0 LAYING FLOORING, SUBFLOOR SHOULD BE LEVEL, WITH HOLES, CRACKS AND DEPRESSIONS FILLED. USE THE PRIMER AND ADHESIVE REW MENDED BY T14E MANUFACTURER BUTT FLOORNG TIGHTLY t0 VERTICAL SURFACE, THRESHOLDS AND EDGINGS. PROVIDE RESILIENT BASE OF THE COLOR, SIZE, TYPE AND MANUFACTURER SHOUR SECURE BASES t0 81URFACES WITH THE ADHESIVE RECOMMENDED BY THE MANUFACTURER WITH TIGHT JOINTS, KEEPING TOP AND BOTTOM EDGES IN FIRM CONTACT WITH ADJACENT SURFACES. INSTALL THEM IN AS LONG LENGTHS AS PRACTICAL.. ORAL CONTRACTOR WILL SUPPLY AND INSTALL TILE GUARD STRIP A. FIN WOOD AS SPECIFIED IN FINISH SCHEDULE AND RESP. SCHEDULE NSt ED PER MANUFAGtIIRERB PRINTED INSTRUCTIONS t RECOMM. B. MATERIAL SHALL BE LISTED WITH UNDERILIWI'ERS LAB. AS TO FIRE AND RESISTANCE. C. A rJ4TECTURAL ire. REDUCER STRIPS, BANDS, PICKETS, C - SHALL BE OF MANUF. AND FINISH AS WOOD FLOOR D. SURFACE t0 RECEIVE ISH FLOORING SHALL BE MATERIAL. WHICH WOULD DETRIMENTAL TO THE E. CONCRETE SUBSTRATES BE DRY, CLEAN,,d TOLERANCE OF 118' INCH N 10'- 'AND ARE TQ` OR SEALERS. CONC. CURING COMPLETELY REMOVED. R SHOULD PATCHING OR LEVELING 8E COMPOUND. DO NOT N =CASE CASE USE A LATEX LEVoR CO G. ALL CONCRETE MUST BE (ALSO OPEN GRIT PAPER t0 L DIRT AND CLEAW OF ALL FOREIGN BION OF THE FLOORING IOOT14 4 LEVEL, WITH A NTAIN NO CJRING COMPOUND8 SEALERS MUST BE USE LATEX CEMENT PATCHING T UNDERLAYI"ENT. DO NOT N ANY 'VER LARGE OR ENTIRE AREA. -:��PATCWING OR LEVELING) WITH 3 1/2 CONCRETE. H. ALL SUB -FLOORING BE FREE OF MORTAR T Y DRY AND THEN BI�SHED, CLEANED VACUUMED TO REMOVE ALL DUST ARTICLES. I. SLABS ON GRAD SHALL BE MEMBRANE WATERPROOFED. J. EACH FL ILE MUST BE FIRMLY SEATED N THE ADHESIVE, THE FLOOR U T14 A P0151D ROLLER K AS MUCH EXPANSION SPACE AS PRACTICAL BETILEEN FLOORR4Ca ICAL OBSTRUGtM. SPACE IS t0 BE FILLED WITH SUITABLE MATER AS CORK OR POLYURETK*E EXPANSION JOINT FILLER SEE GETERAL NOTES FOR ADDITIONAL INFORMATION. 99680 CARPET: MATERIAL SUPPLIED AND INSTALLED BY TENANT. NO CARPET WORK SHALL BE INSTALLED UNTIL WET TRADES ARE COMPLETE N THE SAME AREA. SUB -FLOOR SHOULD BE LEVEL, WITH HOLES, CRACKS AND DEPRESSIONS FILLED AND PROTRJDINIG SURFACES LEVELED BEFORE THE CARPET CAN BE INSTALLED. AFTER INSTALLATION OF CARPET, GENERAL CONTRACTOR SHALL PROTECT CARPETING AGAINST DAMAGE OF EVERY KIND AND ESPECTIALLY N THOSE ZONES WHERE TRAFFIC OF ANY C'.ONSEQLENCES CAN REASONABLY BE EXPECTED TO OCCUR 09900 PANTNCx PROVIDE PANTING AS SHOILN OR SPECIFIED. THE TERM 'PANT' INCLUDES ALL OPAQUE OR NATURAL, PRIME, INTERMEDIATE OR FINISH COATS OF FIELD APPLIED COATINGS. APPLY PANT N ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. USE APPLICATORS AND TECHNIQUES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. PROVIDE TOP-OF-THE-LNE PANT PRODUCTS MAR FACTURED BY ONE OF THE FOLLOWING MANUFACTURERS: ALL DESCRIPTIONS BASED ON SHERWIN-WILLIAMS: BENJAMIN MOORE, PPG INDUSTRIES, SHERWIN-WILLIAMS, PRATT t LAMBERT, GLIDDEN, NAPCO, BUTE PROVIDE SUITABLE COVERING t0 PROTECT WORK, THE WORK OF OTHERS AND ADJACENT SIIFACES AND OBJECTS. REMOVE OR PROTECT SUCH ITEMS AS HARDWARE, ACCESSORIES, PLATES, LIGHT FIXTURES AND SIMILAR ITEMS PLACED PRIOR TO PANTING. REPOSITION OR REMOVE PROTECTION UPON COMPLETION OF EACH SPACE. PREPARE SURFACES t0 RECEIVE PAINT: THOROUGHLY CLEAN OFF GRIME, GREASE, DIRT, CHALK DUST, LOOSE MATERIAL AND OTHER SUBSTANCES THAT MAY INTERFERE WITH PROPER ADHESION OF PANT. PANT DRY SURFACE ONLY. SAND LIGHTLY BETWEEN EACH SUCCEEDING COAT OF PAINT. FILL DENTS, CRAC'.KS,14OLLOW PLACES, OPEN JOINTS AND OTHER IRREGULARITIES WTHI AN APPROVED FILLER SUITABLE FOR THE PURPOSE. AFTER SETTING, SAND TO A SMOOTH, HARD FIN18H. CLEAN OFF ALL PANT SPLATTER OCCURRING ON ADJACENT WORK REPAIR OR REPLACE WITH NEW APPROVED MATERIAL ALL SURFACES DEFACED AS A RESULT OF THE WORK OF THIS SECTION AND LEAVE WORK IN A CLEAN, ACCEPTABLE CONDITION. DRYWALL - PRIME GYPSUM BOAR SURFACES WITH A LATEX PRIMER AND APPLY TWO (2) COATS OF ACRYLIC LATEX, 'REGAL WALL SATIN' (FLAT). WOODWORK: PRIME WOODWORK SURFACES AND TRAMS WITH A WOOD PRIMER, AND APPLY TWO (2) COATS OF 'REGAL AQUAGLO' SATN FINISH ENAMEL. WHEN TRANSPARENT FINISHES ARE CALLED FOR USE MULTIPLE COATS t0 PRODUCE GLASS -SMOOTH SURFACE FILM OF EVEN LUSTER PROVIDE SATN FNIS14 FOR FINAL COAT. METAL WORK;- PRIME ORK:PRIME METAL SURFACES (AG REGISTERS AND DIFFUSER ACCESS PANELS) WITH AN ADEQUATE PRIMER AND APPLY TWO (2) COATS OF FLAT LATEX TO MATCH CEILING COLOR PAINT INTERIOR SURFACES O.D. DUCTS WHERE VISIBLE THROUGH REGISTERS OR GRILLES WITH A FLAT, NON SPECULAR BLACK PANT. OMIT PRIMER ON SURFACES THAT HAVE BEEN SHOP -PRIMED. METAL DOORS: PRIME DOOR SURFACES AND TRIM WITH ENAMEL PRIMER AND APPLY TWO (2) COATS OF SATIN FINISH ENAMEL AS SCHEDULED. PLASTER= PRIME PLASTER SURFACES WITH AN APPROVED ALKALI -RESISTANT PRIMER AND APPLY TWO (2) COATS OF ACRYLIC LATEX (FLAT) AS SCHEDULED. 09985 SLATWALL= MATERIAL PROVIDED BY CLAIRE'S. CONTRACTOR TO PLACE ORDER WITH PROJECT MANAGER AT CLAIRE'S BOUTIQ ES. INSTALL SO GROOVES RUN NORZCNTALLY. VERTICAL JOINTS TO BE CONTINUOUS AS SHOWN ON ELEVATIONS. BUTT JOINT MITER CORNERS DO NOT CAULK BUTT JOINTS. INSTALL SW -2 N STOCK ROOM ,AFTER SALES AREA HAS BEEN COMPLETED. INSTALLATION: FASTEN WITH PANEL ADHESIVE AND TRIM HEAD DRY WALL SCREWS PLACE SCREWS EVERY 4TH GROOVE AND 16' OTC. INTO METAL STUDS. PAINT SCREW HEADS TO MATCH GROOVE COLOR 0x30 ILLUMINATED SIGNS AND CEILING ELEMENTS: SUPPLIED AND INSTALLED BY TENANT'S SIGN CONTRACTOR GENERAL CCNTRACTOR SHALL COORDINATE INSTALLATION TO ASSURE PROPER COMPLIANCE WITH CONSTRUCTION DOCUMENTS AND LANDLORD CRITERIA. 10440 NTERIOR 84*4AGE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR AS PER MANNFACTURER'S NSTRLICTIONS. REFER TO DRAWINGS FOR TYPE AND LOCATION. 10800 TOILET ACCESSORIES: PROVIDE PRODUCTS AS SHOWK FURNISH NSERTS AND ANCHORING DEVICES FOR THE TYPE OF SUBSTRATE WHERE ACCESSORIES ARE TO BE INSTALLED. USE CONCEALED FASTENERS WHEREVER POSSIBLE INSTALL EXPOSED MOUNTING DEVICES WITH FASTENERS FINISHED TO MATCH THE ACCESSORIES. SC'.HEDULES: THE FOLLOWING ITEMS ARE BASED UPON PRODUCTS MANNFACTURED BY BOBIRICK WASHROOM EQUIPMENT, INC. EGUIVALENT PRODUCTS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED WITH TENANT'S APPROVAL. ITEM MANFACTURER MTC. HEIGHT RROOLLEDR PAPER TOWEL RUBBERMAID OR EQUAL TOILET TISSUE HOLDER BOBRICK 05-685 BOT. AT 19' AFF. COAT HOOK / BUMPER 50BRICK +8-212 BOT AT 12' AFF MIRROR IWX 30' BOBRICK 08-250 BOT. At 40' AFF. GRAB BARS TO MEET CODE REQUIREMENTS OR BOBRIC K 48-6106 X 36' DOMCK "-6106 X 48' WISEX40MICAP MOHAUJK 0200A BOT. AT 48' AFF. TOILET ROOM SIGN FORMAT D COAT HOOK BOBRICK 48-212 BOT. At 60' AFF. MISCELLANEOUS NOTES= L THE RECEIPT AND USE OF THESE DOCUMENTS CONSTITUTES AGREEMENT THAT EXISTING PROJECT CONDITIONS, INCLUDING THE PRESENCE OF ASBESTOS OR ASBESTOS CONTAINING MATERIALS, ARE AND REMAIN ISSUES OUTSIDE THE SCOPE ADDRESSED BY THESE DOCUMENTS AND THAT THE ARCHITECT PREPARING THESE DOCUMENTS SHALL NOT, IN ANY WAY, BE LIABLE FOR THE PRESENCE, DISCOVERY, REMOVAL OR HANDLING OF SUCH MATERIALS. 2. ANY WORK NOTED ON DRAWINGS AS BY TENANT SHALL BE THE RESPONSIBILTY OF THE CONTRACTED GENERAL CONTRACTOR 3. THESE SPECIFICATIONS MAY INCLUDE SECTIONS WHICH ARE NOT INCLOED N THE SCOPE OF WORK END OF DIVISION PART 1 - GENERAL A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT WORK AND PLACEMENT WITH THE WORK OF ALL OTHER TRADES AND MAKE ADJUSTMENTS AS REQUIRED TO ACCOMMODATE LOCATIONS OF EQUIPMENT. B. ALL EQUIPMENT WORK SHALL COMPLY WITH ALL GOVERNING BUILDING CODES AND LOCAL CODES. C. EQUIPMENT SHALL BE FURNISHED, UNLOADED, UNPACKED OR UNRATED AND PLACED ACCORDING TO THE CONSTRUCTION DOCUMENTS. PART 2 - PREPARATION / EXECUTION A. ALL EQUIPMENT PROVIDED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR IS TO BE INCLUDED IN GENERAL BID. B. ORAL CONTRACTOR SHALL NOTIFY THE OWNER UTIEDIATELY OF ANY DAMAGE TO THE EQUIPMENT PRIOR TO INSTALLATION. C. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL HOOKUP OF ALL EQUIPMENT SUCH AS ALL MECHANICAL WORK, PLUMBING, AND ELECTRICAL FOR THE EQUIPMENT LIST. D. ALL EQUIPMENT MANUALS, INSTRUCTION BOOKLETS AND WA MWI`Y INFORMATION SHALL BE NEATLY BOUND AND TUlIeW 01VER TO THE OWNER BEFORE FINAL APPROVAL OF THE BUILDING. END OF DIVISION DIVISION 012000 - FURNISHINGS L SEE PLANS FOR SPECIFIC FURNITURE AND FURNISHING TO BE PROVIDED BY GENERAL CONTRACTOR END OF DIVISION DIVISION 015000 - MECHANICAL L SEE MECHANICAL DRAWINGS FOR SPECIFICATIONS. 2. SPRINKLER LAYOUT: THE SPRNCLER aeccNTRAcTOR SHALL MODIFY THE EXISTNG DESIGN AND PROVIDE AN APPROVED 'CALCULATED' SPRINKLER SYSTEM LAYOUT t0 THE ARCHITECT THAT CONFORM t0 NEW DESIGN. THE DESIGN LAYOUT PROVIDED HEREIN REFLECTS THE VISUAL LAYOUT DESIRED. REVISIONS MUST BE SENSITIVE TO THE OVERALL VISUAL IMPACT. DRAWINGS AND CALCULATION* FOR SUCH SYSTEMS SHALL BE SUBMITTED TO THE OWNER'S INSURANCE AGENCY (PRIOR TO FAERICATIONI OF ANY MATERIAL) FOR REVIEW AND APPROVAL PRIOR TO SUBMISSION OF THE CODE REVIEW AUTHORITY. DRAWINGS AND CALCULATIONS MUST ALSO BE S&ED AND SEALED BY AN ENGINEER LICENSED IN THE STATE WHERE THE SUBJECT BUILDING IS LOCATED. ALL COST FOR REVIEW, PERMIT, SIGNING AND SEALING OF DRAWINGS AND CALCULATION SHALL BE BORNE BY THE SPRINKLER SUBCONTRACTOR END OF DIVISION DIVISION 016000 - ELECTRICAL 1. SEE ELECTRICAL DRAWINGS FOR SPECIFICATIONS. END OF DIVISION w Ulu z z w n N O 0 d Z OC Lu O w 13 »d O Q O Cq v9 0 - -W Pu tu gJa 16d� = d * I v kip ti M y ICA CA IL VIM � LLL th � M a a� mv In M U) w ry O ♦vJ vJ 0 ui ILL �U Q 00 U z �.. Lo Q LLL Q Lf) � Q C)Q N OWWz0 z WLLJ J Z W P w OQ Lu L U)17CQ U U U revisions: checked by: PH/JL drawn by: PH STAFF date: 4/23/04 sheet no: SP2 arch. project,b4-153 • ASTERISK INDICATES NO REVISION MADE TO THIS SHEET E E E r r r m E ALL WORK IN51DE STORE 5HALL GOMPLY WITH LANDLORD'S 5PEGS. GENERAL- FIDE SPF ONKLER NOTES I. CONTRACTOR SHALL PROVIDE DRAWINGS AND HYDRAULIC CALCULATIONS OF THE ENTIRE SYSTEM SIGNED AND SEALED BY THE FIRE SPRINKLER ENGINEER OF REGORD (SPRINKLER CONTRACTOR ENGINEER). 2. THE ENTIRE SPACE SHALL BE FIRE 5PRINKLERED IN ACCORDANCE WITH NFPA, LOCAL AND STATE BUILDING CODES AND BUILDING OWNER'S INSURANCE UNDERWRITERS. 3. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL FIRE MAINS AND SPRINKLER HEADS WITH OTHER TRADES. 4. CONTRACTOR SHALL COORDINATE ALL THEIR Y40RK WITH OTHER TRADES AND FIELD CONDITIONS. 5. A FIRE SPRINKLER SYSTEM MAY EXIST IN THE SPACE. CONTRACTOR SHALL REUSE, -RE-WORK OR ADD TO THE EXISTING SYSTEM AS NECESSARY TO COORDINATE WITH NEV4 REFLECTED GEILIN6 PLAN AND NOTE 2. 6. SPRINKLER HEADS SHALL BE: (A5 APPROVED BY LANDLORD AND LOCAL FIRE MARSHALL) A. TOTALLY CONGEALED TYPE FOR FINISHED AREAS, COLOR OF COVER PLATE TO BE SELECTED BY ARCHITECT. B. CHROME PLATED WITH CHROME PLATED ESCUTCHEON PLATE FOR 51DEWALL5. 510ENALL HEADS SHALL BE INSTALLED 50 THAT TOP OF E56UTCHEON PLATE 15 MINIMUM 6" BELOW FIN15HED GEILIN6. G. BRA55 PENDANT FOR UNFIN15HED AREAS. 1. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SPRINKLER SYSTEM. 8. PROVIDE FIRE EXTIN605HER5 PER NFPA #10 AS APPROVED BY LANDLORD AND LOCAL FIRE MARSHALL. GENERAL HVAC NOTES I. GENERAL: A. SUBMIT MANUFACTURERS DATA AND SHOP DRAWINGS ON ALL HVAG EQUIPMENT AND OUGTY40RK FOR'REVIEW BEFORE INSTALLATION. B. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFAGTURER5-REGOMMENDATION5 AND LANDLORD'S TYPICAL DETAIL AND MINIMUM SPECIFICATIONS. G. ALL DIMENSIONS AND ACTUAL CONSTRUCTION CONDITIONS MUST BE VERIFIED AT THE JOB SITE. D. CONTRACTOR SHALL COORDINATE ALL THEIR WORK WITH OTHER TRADES AND FIELD CONDITIONS. E. CONTRACTOR, PRIOR TO 5UBMITTIN6 THEIR BID PRICE, SHALL VISIT THE SITE, FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS, AND SHALL OBTAIN ALL REQUIRED INFORMATION NECESSARY TO COMPLETE THE JOB. ANY DISCREPANCIES BETWEEN WHAT 15 5HOWN ON THE DRAWINGS AND ACTUAL WORK REQUIRED TO COMPLETE THE JOB SHALL BE TAKEN INTO ACCOUNT IN THE BID PRICE. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FOLLOWING CODES AND5TANDARD5: A. ALL APPLICABLE BUILDING CODES. B. NFPA-GOA AIR CONDITIONING AND VENTILATION. G.NFPA-61 BLOWER AND EXHAUST SYSTEMS. D. A5HRAE GUIDE - EQUIPMENT, 5Y5TEM AND APPLICATIONS. E. 5MAGNA - LOW VELOCITY DUCT CONSTRUCTION. F. NFPA 101 SAFETY TO LIFE FROM FIRE IN BUILDINGS. 3. MATERIALS: A. DUCTWORK: I. ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL (NO FIBER61-A55 OUGTWORK 15 PERMITTED). 2. OUGTWORK TO BE EXTERNALLY INSULATED WITH 2" THICK, I POUND DENSITY FIBERGLASS INSULATION WITH EXTERIOR FOIL FACE VAPOR BARRIER FASTEN WITH FLARE TYPE STAPLES ON I" ON CENTER ALONG OVERLAP. SEAL ALL JOINTS, STAPLE HEADS AND SEAMS WITH APPROVED FIRE"RE515TANT MASTIC (R=(o MIN). 3. PROVIDE AIR EXTRACTORS IN ALL -RECTANGULAR BRANCH TAPS. 4. -ROUND BRANCH TAPS SHALL BE MADE WITH "SPIN -IN" TYPE GOLLAR5 WITH VOLUME DAMPER AND ADAPTER FOR CONNECTION TO DUCT. 5. DUGTWORK INSTALLATION AND FABRICATION SHALL BE DONE IN A(GORDANCE WITH 5MAGNA STANDARDS. 6. FLEXIBLE DUCTS: DUCT SHALL BE LIGHTWEIGHT CONSTRUCTED WITH CORROSION -RESISTANT GORE AND REINFORCED WITH E30NDEO HELIX. DUCT TO BE INSULATED WITH 2" THICK, I POUND FIBERGLASS BLANKET INSULATION WITH ALUMINUM FILM VAPOR BARRIER. DUCT SHALL BE L15TED GLASS I, U.L. STANDARD 181. MAXIMUM FLEXIBLE DUCT LENGTH TO BE 5'-0". 1. WHERE DUCTWORK 15 5PEGIFIGALLY NOTED AS MEDIUM PRE55URE, IT SHALL BE GON5TRUGTEO IN ACCORDANCE WITH 5MAGNA 5TANDAR05 FOR A PRE55URE RATING OF 4 INCHES WATER COLUMN MINIMUM OR GREATER AS REQUIRED BY LANDLORD. 6. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF 5MAGNA STANDARDS FOR MEDIUM PRE55DRE DUCT AND LANDLORD'S CRITERIA. G. CONNECTIONS TO THE LANDLORD'S MEDIUM PRE55ME DUCTWORK SHALL BE MADE WITH "LO -1-055" SADDLE TEE TAPS BY UNITED MG61LL CORP., OR AS OTHERWI5E'REQUIRED BY THE LANDLORD. 10, ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS 5EGTION, WITH THE EXCEPTION THAT ALL MEDIUM PRES50RE DUCTYVRK MUST BE WRAPPED INSULATION, NOT LINED. 4. INSULATION: A. INSULATE NECK, THROATS AND COLLARS OF SUPPLY OUTLETS ABOVE THE GEILIN6. 5. HAN6ER5 - 4" AND SMALLER 6RINELL #115. 6. EQUIPMENT A5 5PEGIFIED ON SCHEDULE. 1. PROVIDE TURNING VANES IN ALL ELBOW5 (EXGEPT ON 6REA5EDUCT5), AIR EXTRACTORS OR ADJUSTABLE TURNING VANES AT ALL BRANCH TAKEOFFS AND ALL REQUIRED DAMPERS TO PROPERLY BALANCE THE SYSTEM. 8. CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL DIFFUSERS, &RILLE5 AND-RE615TER5 WITH INTERIOR DE516NER5 DRAWINGS. 6. PROVIDE APPROVED FIRE DAMPERS WITH AGCE55 PANELS AT ALL PENETRATIONS OF FIRE RATED PARTITIONS, WALL5 AND CEILINGS AS A5 REQUIRED BY CODE. 10. A COPY OF THE CERTIFIED AIR BALANCE REPORT SHALL BE SUBMITTED TO THE OWNER AND LANDLORD, THE REPORT NEEDS TO BE INCLUDED IN THE (56 5 FINAL APPLICATION FOR PAYMENT PACKAGE. THI5 WILL BE -REQUIRED ON ALL STORES, RE6ARDLE55 OF THE HVAG 50OPE OF WORK. FDA Irl m� AGGU-I NOTES MARK FIXTURE FIRE PROTECTION PLAN LEGEND DAMPERS SHALL BE OPERABLE FROM FACE -RECE55ED SPRINKLER HEAD "A' OPPOSED BLADE *AG -35. 0WITH WHITE POP-OFF GAP FIRE PROTECTION SPRINKLER HEAD "B"RADIAL OPPOSED BLADE 00-15. LOCATIONS ADDED TO CEILING PLAN. - - - - ® RECE55ED SPRINKLER HEAD THE LO( ATION5 SHOWN ARE APPROX. 'D' YOUN6'S-RE6ULAT0R, DPR MODEL a 5020 -CC 0 CHROME FIN15H LOCATIONS TO BE FIELD VERIFIED. ------L--------� 500 ------------T----1\ --I�----}I�----�I�---� A 5EPERATE PERMIT WIIL BE OBTAINED "A" SURFACE MOUNTED PENDANT SPRINKLER HEAD BY THE 5PINKLER CONTRACTOR. "B" LAY -IN, PROVIDE WITH TITUS MODEL #XY-13363 FRAME CHROME FIN15H H -I A U 1600 3/8" G.P. SUPPLY WITH LOOSE KEY STOP. I.6 6PH GENERAL- FIDE SPF ONKLER NOTES I. CONTRACTOR SHALL PROVIDE DRAWINGS AND HYDRAULIC CALCULATIONS OF THE ENTIRE SYSTEM SIGNED AND SEALED BY THE FIRE SPRINKLER ENGINEER OF REGORD (SPRINKLER CONTRACTOR ENGINEER). 2. THE ENTIRE SPACE SHALL BE FIRE 5PRINKLERED IN ACCORDANCE WITH NFPA, LOCAL AND STATE BUILDING CODES AND BUILDING OWNER'S INSURANCE UNDERWRITERS. 3. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL FIRE MAINS AND SPRINKLER HEADS WITH OTHER TRADES. 4. CONTRACTOR SHALL COORDINATE ALL THEIR Y40RK WITH OTHER TRADES AND FIELD CONDITIONS. 5. A FIRE SPRINKLER SYSTEM MAY EXIST IN THE SPACE. CONTRACTOR SHALL REUSE, -RE-WORK OR ADD TO THE EXISTING SYSTEM AS NECESSARY TO COORDINATE WITH NEV4 REFLECTED GEILIN6 PLAN AND NOTE 2. 6. SPRINKLER HEADS SHALL BE: (A5 APPROVED BY LANDLORD AND LOCAL FIRE MARSHALL) A. TOTALLY CONGEALED TYPE FOR FINISHED AREAS, COLOR OF COVER PLATE TO BE SELECTED BY ARCHITECT. B. CHROME PLATED WITH CHROME PLATED ESCUTCHEON PLATE FOR 51DEWALL5. 510ENALL HEADS SHALL BE INSTALLED 50 THAT TOP OF E56UTCHEON PLATE 15 MINIMUM 6" BELOW FIN15HED GEILIN6. G. BRA55 PENDANT FOR UNFIN15HED AREAS. 1. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SPRINKLER SYSTEM. 8. PROVIDE FIRE EXTIN605HER5 PER NFPA #10 AS APPROVED BY LANDLORD AND LOCAL FIRE MARSHALL. GENERAL HVAC NOTES I. GENERAL: A. SUBMIT MANUFACTURERS DATA AND SHOP DRAWINGS ON ALL HVAG EQUIPMENT AND OUGTY40RK FOR'REVIEW BEFORE INSTALLATION. B. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFAGTURER5-REGOMMENDATION5 AND LANDLORD'S TYPICAL DETAIL AND MINIMUM SPECIFICATIONS. G. ALL DIMENSIONS AND ACTUAL CONSTRUCTION CONDITIONS MUST BE VERIFIED AT THE JOB SITE. D. CONTRACTOR SHALL COORDINATE ALL THEIR WORK WITH OTHER TRADES AND FIELD CONDITIONS. E. CONTRACTOR, PRIOR TO 5UBMITTIN6 THEIR BID PRICE, SHALL VISIT THE SITE, FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS, AND SHALL OBTAIN ALL REQUIRED INFORMATION NECESSARY TO COMPLETE THE JOB. ANY DISCREPANCIES BETWEEN WHAT 15 5HOWN ON THE DRAWINGS AND ACTUAL WORK REQUIRED TO COMPLETE THE JOB SHALL BE TAKEN INTO ACCOUNT IN THE BID PRICE. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FOLLOWING CODES AND5TANDARD5: A. ALL APPLICABLE BUILDING CODES. B. NFPA-GOA AIR CONDITIONING AND VENTILATION. G.NFPA-61 BLOWER AND EXHAUST SYSTEMS. D. A5HRAE GUIDE - EQUIPMENT, 5Y5TEM AND APPLICATIONS. E. 5MAGNA - LOW VELOCITY DUCT CONSTRUCTION. F. NFPA 101 SAFETY TO LIFE FROM FIRE IN BUILDINGS. 3. MATERIALS: A. DUCTWORK: I. ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL (NO FIBER61-A55 OUGTWORK 15 PERMITTED). 2. OUGTWORK TO BE EXTERNALLY INSULATED WITH 2" THICK, I POUND DENSITY FIBERGLASS INSULATION WITH EXTERIOR FOIL FACE VAPOR BARRIER FASTEN WITH FLARE TYPE STAPLES ON I" ON CENTER ALONG OVERLAP. SEAL ALL JOINTS, STAPLE HEADS AND SEAMS WITH APPROVED FIRE"RE515TANT MASTIC (R=(o MIN). 3. PROVIDE AIR EXTRACTORS IN ALL -RECTANGULAR BRANCH TAPS. 4. -ROUND BRANCH TAPS SHALL BE MADE WITH "SPIN -IN" TYPE GOLLAR5 WITH VOLUME DAMPER AND ADAPTER FOR CONNECTION TO DUCT. 5. DUGTWORK INSTALLATION AND FABRICATION SHALL BE DONE IN A(GORDANCE WITH 5MAGNA STANDARDS. 6. FLEXIBLE DUCTS: DUCT SHALL BE LIGHTWEIGHT CONSTRUCTED WITH CORROSION -RESISTANT GORE AND REINFORCED WITH E30NDEO HELIX. DUCT TO BE INSULATED WITH 2" THICK, I POUND FIBERGLASS BLANKET INSULATION WITH ALUMINUM FILM VAPOR BARRIER. DUCT SHALL BE L15TED GLASS I, U.L. STANDARD 181. MAXIMUM FLEXIBLE DUCT LENGTH TO BE 5'-0". 1. WHERE DUCTWORK 15 5PEGIFIGALLY NOTED AS MEDIUM PRE55URE, IT SHALL BE GON5TRUGTEO IN ACCORDANCE WITH 5MAGNA 5TANDAR05 FOR A PRE55URE RATING OF 4 INCHES WATER COLUMN MINIMUM OR GREATER AS REQUIRED BY LANDLORD. 6. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF 5MAGNA STANDARDS FOR MEDIUM PRE55DRE DUCT AND LANDLORD'S CRITERIA. G. CONNECTIONS TO THE LANDLORD'S MEDIUM PRE55ME DUCTWORK SHALL BE MADE WITH "LO -1-055" SADDLE TEE TAPS BY UNITED MG61LL CORP., OR AS OTHERWI5E'REQUIRED BY THE LANDLORD. 10, ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS 5EGTION, WITH THE EXCEPTION THAT ALL MEDIUM PRES50RE DUCTYVRK MUST BE WRAPPED INSULATION, NOT LINED. 4. INSULATION: A. INSULATE NECK, THROATS AND COLLARS OF SUPPLY OUTLETS ABOVE THE GEILIN6. 5. HAN6ER5 - 4" AND SMALLER 6RINELL #115. 6. EQUIPMENT A5 5PEGIFIED ON SCHEDULE. 1. PROVIDE TURNING VANES IN ALL ELBOW5 (EXGEPT ON 6REA5EDUCT5), AIR EXTRACTORS OR ADJUSTABLE TURNING VANES AT ALL BRANCH TAKEOFFS AND ALL REQUIRED DAMPERS TO PROPERLY BALANCE THE SYSTEM. 8. CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL DIFFUSERS, &RILLE5 AND-RE615TER5 WITH INTERIOR DE516NER5 DRAWINGS. 6. PROVIDE APPROVED FIRE DAMPERS WITH AGCE55 PANELS AT ALL PENETRATIONS OF FIRE RATED PARTITIONS, WALL5 AND CEILINGS AS A5 REQUIRED BY CODE. 10. A COPY OF THE CERTIFIED AIR BALANCE REPORT SHALL BE SUBMITTED TO THE OWNER AND LANDLORD, THE REPORT NEEDS TO BE INCLUDED IN THE (56 5 FINAL APPLICATION FOR PAYMENT PACKAGE. THI5 WILL BE -REQUIRED ON ALL STORES, RE6ARDLE55 OF THE HVAG 50OPE OF WORK. FDA Irl m� AGGU-I AIR DISTRIBUTION DEVICE SCHEDULE NOTES MARK FIXTURE I. SYMBOL KEY - 5. DAMPERS SHALL BE OPERABLE FROM FACE FtR5T LETTER: 5-5UF'PLY'R-RETURN E-EXHAU5T "A' OPPOSED BLADE *AG -35. SECOND LETTER: O -DIFFUSER R-RE615TER G -GRILLE "B"RADIAL OPPOSED BLADE 00-15. �RG-I I 1 - - - - ® _ _ _-_L - - - O0 'D' YOUN6'S-RE6ULAT0R, DPR MODEL a 5020 -CC -----�__ -- ------L--------� 500 ------------T----1\ --I�----}I�----�I�---� p w v _ 0 a C Lu 0 "A" SURFACE MOUNTED A. FINISH- "B" LAY -IN, PROVIDE WITH TITUS MODEL #XY-13363 FRAME "A" TITU5 STANDARD WHITE FINISH.. H -I A U 1600 3/8" G.P. SUPPLY WITH LOOSE KEY STOP. I.6 6PH "C" LAY -IN FRAME FOR T -BAR GEILIN6. f---35D-I 100 71F II_ Ij l8"xl4' MOUNTING MATERIAL 14"xl2"��- pPR, BORDER REMARKS I III III. CENTERS, GERAMIX 2000.100 FAUCET, NO. 1116.016 500 O 500 � -- - II j1 &RID DRAIN WITH 1 1/4" T.P., 1 1/4" G.P., 11 GA. "P" TRAP, FNM i li _ NECK GLC. OTHER STEEL ALUM, W �--- F-�- ---�- -----------I- -�-}--- ----- -♦-I---t1= ----�---------r-- ---T-- ---}I� --�----tl�---+-I��- 24"x24" 12"( • AIR DISTRIBUTION DEVICE SCHEDULE NOTES MARK FIXTURE I. SYMBOL KEY - 5. DAMPERS SHALL BE OPERABLE FROM FACE FtR5T LETTER: 5-5UF'PLY'R-RETURN E-EXHAU5T "A' OPPOSED BLADE *AG -35. SECOND LETTER: O -DIFFUSER R-RE615TER G -GRILLE "B"RADIAL OPPOSED BLADE 00-15. Q "C"�RUSKIN CFD OR GFDR FIRE DAMPER W/VOLUME CONTROL. 2.GATALOG NUMBERS REFER TO TITU5 AIR DEVICES. 'D' YOUN6'S-RE6ULAT0R, DPR MODEL a 5020 -CC 3.PROVIDE #DB DIRECTIONAL BLOW FOR OTHER 6. BORDER STYLE - THAN 4 -WAY. "A" SURFACE MOUNTED A. FINISH- "B" LAY -IN, PROVIDE WITH TITUS MODEL #XY-13363 FRAME "A" TITU5 STANDARD WHITE FINISH.. FOR DRYWALL GEILIN6 MOUNTING, 3/8" G.P. SUPPLY WITH LOOSE KEY STOP. I.6 6PH "C" LAY -IN FRAME FOR T -BAR GEILIN6. SYMBOL SIZE MOUNTING MATERIAL FINISH pPR, BORDER REMARKS M v CENTERS, GERAMIX 2000.100 FAUCET, NO. 1116.016 04Cp i 0 QQ LLL � &RID DRAIN WITH 1 1/4" T.P., 1 1/4" G.P., 11 GA. "P" TRAP, FNM NUMBER MOD. NECK GLC. OTHER STEEL ALUM, W STYLE A111.1 APPROVED INSULATE DRAIN AND SUPPLY LINES 50-1 TDG 24"x24" 12"( • JO5AM 1/2" • 3" 3" WITH NIKALOY STRAINER. A NO. 30003-A-50 G LAY -IN 5D-2 TOC, 24"x24" 12"O • • Q A B DRYWALL 50-2 TDG 24"x24' 61cp • Li • A Q G LAY -IN UUUC/-) revisions: checked by: PH JL drown by. PH STAFF dote: 4/23/04 sheet no: m 1 orch. projnt,. - 1 RG -I 25 -RL 24"x24" .22"x22" • • A G LAY -IN RG 25 RL 24x12" 22"xlO" •T • A G LAY -IN GENERAL PLUMBING NOTES I. AFTER EXAMINATION OF CONTRACT DOCUMENTS AND SITE WORK, THE BIDDER 15 REQUIRED, BEFORE SUBMITTING THEIR PROPOSAL, TO V151T THE 51TE AND FAMILIARIZE THEMSELVES WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT MATERIAL AND LABOR -REQUIRED. THEREFORE, SINGE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION 5HALL BE GIVEN TO THE EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES TO FAMILIARIZE THEMSELVES WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND/OR CONSTRUCTION (SHOULD BE ANTICIPATED BY THIS CONTRACTOR) TO AVOID CONFLICTS WITH OTHER TRADES, ARE EXPRE55LY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. NE61-I6ENGE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE THEM OF THE OBLIGATION AND RE51PON5113ILITIE5 A55UMED UNDER TH15 CONTRACT. CONTRACT. 2. G.W. 8 H.W. PIPING SHALL BE COPPER TYPE 'L' ABOVE &RADE, TYPE 'K' BELOW GRADE, WITH I" THICK FI13ER6LA55 INSULATION WITH VAPOR BARRIER AND A5J JACKET. 3. WA5TE AND VENT LINES SHALL BE CAST IRON NO -HUB ABOVE &ROUND, PUSH -ON JOINT WITH NEOPRENE GASKET UNDERGROUND. 4. A/C CONDENSATE SHALL BE COPPER OW, INSULATED WITH I" THICK FIBER6LA55 INSULATION WITH VAPOR BARRIER AND FRJ JACKET. 5. PROVIDE AIR CHAMBERS AND SHUT OFF VALVES AT EACH PLUMBING FIXTURE WATER SUPPLY. 6. FLOOR DRAINS: RE5TROOM5: J05AM 30003-A-50 WITH NIKALOY STRAINER AND CLEANOUT COVERS: WALL - JOSAM 8600-55. 1. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. 8. ALL PLUMBING PIPING SHALL BE PRESSURE TESTED AND CHLORINATED PER LANDLORD'S MANUAL. G, CONTRACTOR SHALL PAY ALL FEES AND RELATED CHARGES FOR PERMITS, LICENSES, ETC. REQUIRED FOR INSTALLATION OF PLUMBING WORK. MECHANICAL PLAN SCALE: 1/4" = 1'-0' MINIMUM O. A. REOUIREMENTS (per ASHRAE 62-89) REQUIRED: SALES AREA 1152 s.f. x .3 cfm/s.f. = 345 Om NON -SALES AREA 234 s.f. x .15 cfm/s.f. = 35 Om 380 Om 410 CFM OUTSIDE AIR TO BE PROVIDED THROUGH ROOFTOP UNIT. INSTANTANEOUS WATER HEATER J -BOX (BY ELEG. CONT) - `-2" TRAP 0- INGO I/2' GW IN WALL FINISHED FLOOR : INSTANTANEOUS WATER HEATER DETAIL AIR CHAMBER (TYP) 10 LAV 13 n to n I/2" TP 1/2" 1/4" TO FQ I/2" EXTEND TO EXISTING GW PIPING STUB. SHUT OFF VALVE A.O. SMITH MODEL #ELG-2 12OV., IS KW "INSTA-HOT" WATER HEATER MOUNTED ON WALL UNDER LAV. 2" VENT LINE, EXTEND VENT MAID I -1/2"I LAV ®Y FDA 2„ f F w" `-4" SAN LINE, EXTEND TO EXIST. STUB. SAWAW STACK N.T.S. MECHANICAL CODED NOTES 10 ML. TO PROVIDE NEW EXHAUST FAN: GROAN #bl4 FAN/L16HT COMBO (W/ #61-71-1 HOUSING AND INSTALL BACK DRAFT DAMPER), 15 CFM, 120V., I PH. PROVIDE 10' x 3 1/2" TRANSITION TO 6" DUCT TO LANDLORD'S TOILET EXHAUST MAIN. FIELD VERIFY EXACT LOCATION OF MAIN. M.G. TO FURNISH AND INSTALL VOLUME DAMPER FOR BALANCING AT TIE-IN TO LANDLORS MAIN EXHAUST DUCT. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL "LIGHTSTAT" #T.M.D. THERMOSTAT. MOUNT THERMOSTAT AT 48" AFF. PROVIDE PLENUM -RATED CONTROL WIRE AND MAKE SYSTEM FULLY FUNCTIONAL. MECHANICAL CONTRACTOR 15 TO CONTACT RON EI&ENBROD OR BETSY RENOUF AT LIGHT5TAT FOR INFORMATION, PRICING, AND DELIVERY AT I-800 2cl2 2444, TO ACQUIRE THE THERMOSTAT DIRECTLY. COORDINATE NIGHT LIGHT TO BE A LEAST 10 FEET FROM T -STAT. F31 MECHANICAL CONTRACTOR TO FURNISH AND INSTALL A CARRIER MODEL #FG31048 NOMINAL 4 TON, IbOOGFM SPLIT SYSTEM OX AIR HANDLING UNIT, 1/3 HP MOTOR, 12OV., I PH., 60 HZ. UNIT TO BE FURNISHED WITH FLAT FILTER SECTION AND 15 TO BE HUNG FROM STRUCTURE AS SHOWN WITH IN-LINE SPRING AND RUBBER VIBRATION ISOLATORS. UNIT OPERATING WEIGHT 15 112 LBS. INSTALL WITH PROPER SERVICE CLEARANCE AREA -RECOMMENDED BY MANUFACTURER OR AS SHOWN ON PLAN. FURNISH UNIT WITH TWO SETS OF FILTERS. REPLACE FILTERS JUST PRIOR TO AIR BALANCE. FURNISH WITH MOTOR MASTER, WINTER START PACKAGE AND 4" DEEP AUXILIARY DRAIN PAN WITH 3/4" DRAIN (SEPARATE FROM CONDENSATE) TO MOP SINK, FLOOR DRAIN. EXTEND IO"RD OUTSIDE AIR DUCT TO ROOF OR WALL GAP AS REQUIRED. 4] MECHANICAL CONTRACTOR TO FURNISH AND INSTALL A CARRIER MODEL #38GKG048 NOMINAL 4 TON AIR COOLED OX CONDENSING UNIT, 208V., 3PH., 60 HZ. UNIT OPERATING WEIGHT IS 138 LBS. MOUNT UNIT ON ROOF WITH PROPER SERVIGE CLEARANCE AREA -RECOMMENDED BY MANUFACTURER. FIELD VERIFY EXACT LOCATION AND-REQUtREMENT5 WITH LANDLORD'S REPRESENTATIVE PRIOR TO BID. FURNISH WITH LOW AMBIENT CONTROLS AND WINTER START KIT. ❑5 MECHANICAL CONTRACTOR TO INSTALL CONDENSATE DRAIN PROM AHU. MINIMUM DRAIN 51ZE TO BE 3/4" OR AS SPECIFIED ON PLAN. CONDENSATE DRAIN TO BE TRAPPED WITH A TRAP DEPTH OF 13 x UNITS TOTAL STATIC PRESSURE. DRAIN SHALL BE EXTENDED TO FLOOR DRAIN LOCATED IN TENANT'S -RESTROOM, PIPING SHALL BE COPPER WITH WROUGHT FITTINGS UNLESS NOTED OTHERWISE. © MECHANICAL CONTRACTOR TO EXTEND REFRIGERANT LINES FROM CONDENSING UNIT TO THE AHU'S OX COIL AND MAKE FINAL CONNECTIONS. REFRIGERANT LINES SHALL BE SIZED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS. FIELD VERIFY EXACT i;ZOOFING-REQUtREMENTS. FMECHANICAL CONTRACTOR TO FURNI5H AND INSTALL DUCT MOUNTED ELECTRIC HEATER 10.0 KW 206V., 3PH. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. ® CONNECT NEW VENT LINE FROM PLUMBING FIXTURES TO LANDLORDS VENT MIAN. VERIFY EXACT LOCATION AND REQUIREMENTS IN FIELD. �6 CONNECT NEW SANITARY LINES FROM FIXTURES TO LANDLORDS MAIN. FIELD VERIFY LOCATION ANDREQUtREMENT5 IN FIELD. 10 PROVIDE NEW PLUMBING FIXTURES. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. II C0NINECT NEW WATER LINES TO EXISTING STUB -IN. FIELD VERIFY EXACT LOCATION AND'REQUtREMENTS. 12 PROVIDE NEW INSTANTANEOUS WATER HEATER. SEE RISER DIAGRAM FOR REQUIREMENTS. 13 ALL WATER LINES, VENT LINES, DRAIN LINES, SPRINKLE=R LINES, ETC. SHALL BE OFFSET BELOW PLATFORM AND CONGEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. DROP ALL WATER LINES DOWN IN WALLS. PROVIDE WATER METER WITH REMOTE READER PER LANDLORDS AND WATER COMPANY REQUIREMENTS. FIELD VERIFY EXACT LOCATION AND -REQUIREMENTS. 15 UNDERCUT TOILET ROOM DOOR I" FOR EXHAUST MAKEUP AIR. 046404t ,gam PLUMBING FIXTURE SCHEDULE MARK FIXTURE MANUFACTURER GW HW WA5TE TRAP REMARKS AND MODEL NO. Q YJG WATER AMERICAN STANDARD 1/2" - 4" - INTE&RAL HANDICAP TANK TYPE, ELONGATED WATER CLOSET NO. 2108.408 N W J iVC ~ SAVER CADET, CHURCH NO, 534.016 OPEN FRONT SEAT, Z= 0 h011� O w Q,wcn �n Ul ui = W Lu� 3/8" G.P. SUPPLY WITH LOOSE KEY STOP. I.6 6PH W Lu LL O FLUSH - 18' MTC. HT. TO BOWL. (A.DA. COMPLIANT) LAY LAVATORY AMERICAN STANDARD 1/2" 1/2" 1 1/2" 1 1/2" WALL MOUNTED DEGLYN VITREOUS CHINA WITH 4" Z m LL 0- NO. 0321.015 M v CENTERS, GERAMIX 2000.100 FAUCET, NO. 1116.016 04Cp i 0 QQ LLL � &RID DRAIN WITH 1 1/4" T.P., 1 1/4" G.P., 11 GA. "P" TRAP, FNM zwrn > [L �wLiN 3/8" G.P. SUPPLIES WITH L005E KEY STOPS, J05AM W m Lu 1: (L(L V ! FLOOR MTD. CARRIER, SINGLE LEVER A.D.A. AND AN51 W ch A111.1 APPROVED INSULATE DRAIN AND SUPPLY LINES 0 ..U') WITH 1/2" ARM5T`RON6 "ARMAFLEX" PIPING INSULATION. FO FLOOR JO5AM 1/2" - 3" 3" 3" WITH NIKALOY STRAINER. DRAIN NO. 30003-A-50 U WGO Q I Q WALL CLEANOUT MECHANICAL CODED NOTES 10 ML. TO PROVIDE NEW EXHAUST FAN: GROAN #bl4 FAN/L16HT COMBO (W/ #61-71-1 HOUSING AND INSTALL BACK DRAFT DAMPER), 15 CFM, 120V., I PH. PROVIDE 10' x 3 1/2" TRANSITION TO 6" DUCT TO LANDLORD'S TOILET EXHAUST MAIN. FIELD VERIFY EXACT LOCATION OF MAIN. M.G. TO FURNISH AND INSTALL VOLUME DAMPER FOR BALANCING AT TIE-IN TO LANDLORS MAIN EXHAUST DUCT. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL "LIGHTSTAT" #T.M.D. THERMOSTAT. MOUNT THERMOSTAT AT 48" AFF. PROVIDE PLENUM -RATED CONTROL WIRE AND MAKE SYSTEM FULLY FUNCTIONAL. MECHANICAL CONTRACTOR 15 TO CONTACT RON EI&ENBROD OR BETSY RENOUF AT LIGHT5TAT FOR INFORMATION, PRICING, AND DELIVERY AT I-800 2cl2 2444, TO ACQUIRE THE THERMOSTAT DIRECTLY. COORDINATE NIGHT LIGHT TO BE A LEAST 10 FEET FROM T -STAT. F31 MECHANICAL CONTRACTOR TO FURNISH AND INSTALL A CARRIER MODEL #FG31048 NOMINAL 4 TON, IbOOGFM SPLIT SYSTEM OX AIR HANDLING UNIT, 1/3 HP MOTOR, 12OV., I PH., 60 HZ. UNIT TO BE FURNISHED WITH FLAT FILTER SECTION AND 15 TO BE HUNG FROM STRUCTURE AS SHOWN WITH IN-LINE SPRING AND RUBBER VIBRATION ISOLATORS. UNIT OPERATING WEIGHT 15 112 LBS. INSTALL WITH PROPER SERVICE CLEARANCE AREA -RECOMMENDED BY MANUFACTURER OR AS SHOWN ON PLAN. FURNISH UNIT WITH TWO SETS OF FILTERS. REPLACE FILTERS JUST PRIOR TO AIR BALANCE. FURNISH WITH MOTOR MASTER, WINTER START PACKAGE AND 4" DEEP AUXILIARY DRAIN PAN WITH 3/4" DRAIN (SEPARATE FROM CONDENSATE) TO MOP SINK, FLOOR DRAIN. EXTEND IO"RD OUTSIDE AIR DUCT TO ROOF OR WALL GAP AS REQUIRED. 4] MECHANICAL CONTRACTOR TO FURNISH AND INSTALL A CARRIER MODEL #38GKG048 NOMINAL 4 TON AIR COOLED OX CONDENSING UNIT, 208V., 3PH., 60 HZ. UNIT OPERATING WEIGHT IS 138 LBS. MOUNT UNIT ON ROOF WITH PROPER SERVIGE CLEARANCE AREA -RECOMMENDED BY MANUFACTURER. FIELD VERIFY EXACT LOCATION AND-REQUtREMENT5 WITH LANDLORD'S REPRESENTATIVE PRIOR TO BID. FURNISH WITH LOW AMBIENT CONTROLS AND WINTER START KIT. ❑5 MECHANICAL CONTRACTOR TO INSTALL CONDENSATE DRAIN PROM AHU. MINIMUM DRAIN 51ZE TO BE 3/4" OR AS SPECIFIED ON PLAN. CONDENSATE DRAIN TO BE TRAPPED WITH A TRAP DEPTH OF 13 x UNITS TOTAL STATIC PRESSURE. DRAIN SHALL BE EXTENDED TO FLOOR DRAIN LOCATED IN TENANT'S -RESTROOM, PIPING SHALL BE COPPER WITH WROUGHT FITTINGS UNLESS NOTED OTHERWISE. © MECHANICAL CONTRACTOR TO EXTEND REFRIGERANT LINES FROM CONDENSING UNIT TO THE AHU'S OX COIL AND MAKE FINAL CONNECTIONS. REFRIGERANT LINES SHALL BE SIZED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS. FIELD VERIFY EXACT i;ZOOFING-REQUtREMENTS. FMECHANICAL CONTRACTOR TO FURNI5H AND INSTALL DUCT MOUNTED ELECTRIC HEATER 10.0 KW 206V., 3PH. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. ® CONNECT NEW VENT LINE FROM PLUMBING FIXTURES TO LANDLORDS VENT MIAN. VERIFY EXACT LOCATION AND REQUIREMENTS IN FIELD. �6 CONNECT NEW SANITARY LINES FROM FIXTURES TO LANDLORDS MAIN. FIELD VERIFY LOCATION ANDREQUtREMENT5 IN FIELD. 10 PROVIDE NEW PLUMBING FIXTURES. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. II C0NINECT NEW WATER LINES TO EXISTING STUB -IN. FIELD VERIFY EXACT LOCATION AND'REQUtREMENTS. 12 PROVIDE NEW INSTANTANEOUS WATER HEATER. SEE RISER DIAGRAM FOR REQUIREMENTS. 13 ALL WATER LINES, VENT LINES, DRAIN LINES, SPRINKLE=R LINES, ETC. SHALL BE OFFSET BELOW PLATFORM AND CONGEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. DROP ALL WATER LINES DOWN IN WALLS. PROVIDE WATER METER WITH REMOTE READER PER LANDLORDS AND WATER COMPANY REQUIREMENTS. FIELD VERIFY EXACT LOCATION AND -REQUIREMENTS. 15 UNDERCUT TOILET ROOM DOOR I" FOR EXHAUST MAKEUP AIR. 046404t ,gam W W� Q Z w N w UM N W J iVC ~ U53 Z= 0 h011� O w Q,wcn �n Ul ui = W Lu� Z 1-d =s W Lu LL O a u J M il1rO� U0 EL aWW >_ U J O :n A W z t- = Q�Q w 13 Z m LL 0- M v 04Cp i 0 QQ LLL � uj LL FNM zwrn > [L �wLiN W m Lu 1: (L(L V ! W ch 0 ..U') C/o O LL.W U rl- 00 U Q Q I Q N L Q Q o� C z CrLLj O �z �w� F- Li � Li O �Q � Q (n _1 Q a- UUUC/-) revisions: checked by: PH JL drown by. PH STAFF dote: 4/23/04 sheet no: m 1 orch. projnt,. - 1 - ASTERISK INDICATES NO REVISION MADE TO THIS 5PEET I 0 N I r WOOD BACKER BOARD (BY OTHERS) WOOD BAGKeR BOARD (BY OTHERS) L _ 12'x12 ACCESS PANEL 1O PLAN SECTION OF CASH/WRAP NTS I I REAR ELEV. OF CASH/WRAP NTS 30/3P/NF/WP (3) # 12 8 (1) #12 GND AGGU-I IN 314"G LANDLORD I TENANT (3) # 2 d r SPLICE I (1) #12 GND IN 3/4"C BOX t -1(E) (4) #6 d (I) #10 GND ISOLATED GROUND DUPLEX REGEPTAGLE (1) #10 GND IN I"G N.E.C. dONNEdTED KVA IN I "G I EXISTING MAIN I - 60 3P O.G. DEVICE, 3 PHONE OUTLET 0 PROVIDE 100 X71-1 1.25 PANEL AMP FUSES --,--*"ILb-0J TELEPHONE TERMINAL BOARD OR CABINET JUNCTION BOX ISI _ I I REAR ELEV. OF CASH/WRAP NTS 30/3P/NF/WP (3) # 12 8 (1) #12 GND AGGU-I IN 314"G LANDLORD I TENANT (3) # 2 d r SPLICE I (1) #12 GND IN 3/4"C 50A� PANEL rsoa G 3m, 4W N &RND B 5 + POWER RISER DIAGRAM NTS 3.00" (TYP) 3.00" (TYP) 15.00" 30.00" -4 0.63 (TYP) (4) HOLES X1.00" TOP CONDUIT OPENINGS HEATER FLOOR NTS A B 0 � FACTORY INSTALLED INTERMATIG ETO215C TIMEGLOGK IF5 GENERAL NOTES: WR CONTROLS TIME L2.00 I. THE DISTRIBUTION SWITGHBOARD IS SUPPLIED BY THE OWNER gO.00 LOCK AND INSTALLED BY THE EG 2. INFORMATION REGARDING TH15 EQUIPMENT MAY BE OBTAINED p o O p p J FROM BEN FACTOR AT WR CONTROLS / WE5G0 0 0 0 0 0 1-800-411-1543 O O G O O O O G O O 3. ALL PANELBOAR05 AND TRAN5FORMER5 WILL BE FACTORY T -I INSTALLED AND GABLED WITH NEC SIZED CONDUCTORS. 15 KVA SEE THE ONE -LINE DIAGRAM FOR DETAILS. THE CONTRACTOR WILL BE'REQUIRED TO MAKE ALL FINAL TERMINATIONS. 0 0 0 0 0 0 0 0'0 0 0 0 0 0 0 4. THE ELECTRICAL CONTRACTOR SHALL COMPLETE THE INITIAL 0 0 0 0 o FLOOR TIME GLOGK SET-UP, PRIOR TO LEAVING THE JOB; COORDINATE HOURS OF OPERATION, INCLUDING 5EA50NAL SECTION TIME GHANGE5 AND HOLIDAY 5GHEDULE5, WITH THE TENANT'S NUMBER I STORE MANAGER AND/OR DISTRICT SALES MANAGER 5EGTION 36.00 5, THE IFS SWITCHBOARD WILL BE PALLETIZED AND SHIPPED WIDTH IN AN ENGL05ED SEMI-TRAILOR. WHERE APPLICABLE, THE SHIPPING 36.00 CONTRACTOR 15 RESPONSIBLE FOR UNLOADING AND SECTIONS INSTALLATION. 6. A 24-HOUR NOTICE WILL BE GIVEN PRIOR TO DELIVERY. IFS FRONT ELEVATION NTS ELECTRICAL LEGEND BOX (4) #6 e -1(E) (4) #6 d (I) #10 GND ISOLATED GROUND DUPLEX REGEPTAGLE (1) #10 GND IN I"G N.E.C. dONNEdTED KVA IN I "G 10 EXISTING MAIN I 10 60 3P O.G. DEVICE, 3 PHONE OUTLET 0 PROVIDE 100 X71-1 1.25 PANEL AMP FUSES --,--*"ILb-0J TELEPHONE TERMINAL BOARD OR CABINET JUNCTION BOX 1 21'7/ pV 1 $3 WALL 5WITGH, 3 = 3 -WAY CG 30, 4W N EXISTING LQ 5A POWER CO. M SIZE, 3P= NO. OF POLES, NF= NDN -FUSED, 01000 METER z LO T -i 15 KVA XFMR FIXED ELEd. 0PAdE HEATINd Y= FUSE SIZE, Z= # OF POLE5 PRI. 40p 340, 3w - 1 �PRI SEG, 120/206V 3m, 4w - 0.000 SEG EXISTING CENTRAL AFF ABOVE FINISHED FLOOR 015TR. POINT UNLE55 NOTED OTHERWISE NEUTRAL 50A� PANEL rsoa G 3m, 4W N &RND B 5 + POWER RISER DIAGRAM NTS 3.00" (TYP) 3.00" (TYP) 15.00" 30.00" -4 0.63 (TYP) (4) HOLES X1.00" TOP CONDUIT OPENINGS HEATER FLOOR NTS A B 0 � FACTORY INSTALLED INTERMATIG ETO215C TIMEGLOGK IF5 GENERAL NOTES: WR CONTROLS TIME L2.00 I. THE DISTRIBUTION SWITGHBOARD IS SUPPLIED BY THE OWNER gO.00 LOCK AND INSTALLED BY THE EG 2. INFORMATION REGARDING TH15 EQUIPMENT MAY BE OBTAINED p o O p p J FROM BEN FACTOR AT WR CONTROLS / WE5G0 0 0 0 0 0 1-800-411-1543 O O G O O O O G O O 3. ALL PANELBOAR05 AND TRAN5FORMER5 WILL BE FACTORY T -I INSTALLED AND GABLED WITH NEC SIZED CONDUCTORS. 15 KVA SEE THE ONE -LINE DIAGRAM FOR DETAILS. THE CONTRACTOR WILL BE'REQUIRED TO MAKE ALL FINAL TERMINATIONS. 0 0 0 0 0 0 0 0'0 0 0 0 0 0 0 4. THE ELECTRICAL CONTRACTOR SHALL COMPLETE THE INITIAL 0 0 0 0 o FLOOR TIME GLOGK SET-UP, PRIOR TO LEAVING THE JOB; COORDINATE HOURS OF OPERATION, INCLUDING 5EA50NAL SECTION TIME GHANGE5 AND HOLIDAY 5GHEDULE5, WITH THE TENANT'S NUMBER I STORE MANAGER AND/OR DISTRICT SALES MANAGER 5EGTION 36.00 5, THE IFS SWITCHBOARD WILL BE PALLETIZED AND SHIPPED WIDTH IN AN ENGL05ED SEMI-TRAILOR. WHERE APPLICABLE, THE SHIPPING 36.00 CONTRACTOR 15 RESPONSIBLE FOR UNLOADING AND SECTIONS INSTALLATION. 6. A 24-HOUR NOTICE WILL BE GIVEN PRIOR TO DELIVERY. IFS FRONT ELEVATION NTS ELECTRICAL LEGEND OX DUPLEXREGEPTAGLE, X=MTC HEIGHT, 18" IU AFF UNO �IG ISOLATED GROUND DUPLEX REGEPTAGLE POWER FAdTOR GROUND FAULT INTERUPTER DUPLEX N.E.C. dONNEdTED KVA REGEPTAGLE 10 QUADUPLEX REGEPTAGLE 10 GEILING MOUNTED DUPLEX-REGEPTAGLE 1.0 PHONE OUTLET 0 DATA OUTLET 1.25 FLOOR TELEPHONE OUTLET REdEPTAduo TELEPHONE TERMINAL BOARD OR CABINET JUNCTION BOX OJ $3 WALL 5WITGH, 3 = 3 -WAY 1.0 < 10 K* 0.6 QNDR WtRELESB SEN50R / ANNUNCIATOR LQ NON-FUSED 015GONNEGT SWITCH, X= 0156. 019 SIZE, 3P= NO. OF POLES, NF= NDN -FUSED, 01000 WP= WEATHERPROOF z LO FUSED 015GONNEGT, X= 015GONNECT SIZE; FIXED ELEd. 0PAdE HEATINd Y= FUSE SIZE, Z= # OF POLE5 Q WR GON7ROL5 IF5 PANEL WP 00ENOTE5 "WEATHERPROOF " EQUIPMENT (R)RELOCATED 0.000 (E) EX15TING AFF ABOVE FINISHED FLOOR UNO UNLE55 NOTED OTHERWISE SCALE: 1/4" = 1'-0" POWER CODED NOTES ❑1 -RECEPTACLE MOUNTED ON CEILING FOR SHOW WINDOW AS REQUIRED BY N.E.G. 21 GONTRACTOR TO TRENGH SLAB AND INSTALL CONDUITS A5 SHOWN. PATCH TRENCH TO MATGH EXISTING FINISH. ❑3 DUPLEXRECEPTACLE MOUNTED AT 5'-6" AFF FOR STEREO SYSTEM. VERIFY EXACT LOCATION IN FIELD. RUN 1/2" DIA. CONDUIT FOR SPEAKER WIRE FROM GABLE OUTLET (05-6" AFF) 6" INTO SALES, 12" TO 15" ABOVE CEILING. 8-13,18 (4 #12 6 1 #12 (IG) - 3/4" G). GKT. #13 TO SERVE PA55 AND SEYMOUR OUTLETS. SEE NOTE 1 BELOW. ❑ 6 3/4" E.G. TO TELEPHONE CABINET. Fil GA5HWRAP IS FURNISHED WITH (2 ) REGEPTAGLE5 ON THE 'RIGHT SIDE AND ( I ) REGEPTAGLE ON THE LEFT SIDE. (REAR FACING) RECEPTACLES ARE PA55 AND SEYMOUR #I6626205P ISOLATED GROUND DUPLEX REGEPTAGLE5; ALL PRE -WIRED BY THE MANUFACTURER AT THE FACTORY, ELEGTRIGAL CONTRACTOR TO GONNEGT GA5HWRAP "WHIP" TO ELEC. PANEL, AS 5HOWN ON THIS SHEET. FIELD VERIFY EXAGT -REQUIREMENTS. ® ANY/ ALL EXISTING RECEPTACLES TO BE REMOVED. FINAL ELECTRICAL LAYOUT TO BE AS SHOWN ON PLAN. ELECTRICAL CONTRACTOR TO FURNI5H AND INSTALL 3/4" CONDUIT W/ PULL WIRE FROM TELEPHONE BOARD TO DESIGNATED TELEPHONE LOCATION AT GA5HWRAP d BAGKWRAP. PHONE COMPANY TO PROVIDE CONDUCTORS AND FINAL CONNECTIONS. THE TELEPHONE COMPANY INSTALLS THE GONDUGTORS, JACKS, AND MAKES THE FINAL CONNECTIONS. CONTRACTOR TO FIELD VERIFY EXAGT REQUIREMENTS AND FIELD LOGATIONS. 10 ACGE55 PANEL MOUNTED IN BOTTOM OF GA5HWRAP COUNTER. II FLEXIBLE CONDUIT RUNNING INSIDE GASHWRAP (IN BASE AT REAR) BY CABINET MANUFACTURER. 12 GFI RECEPTAGLE FOR WATER HEATER, 12OV, 10, 1500W. 13 6F1 RECEPTACLE TO BE MOUNTED AT 48" A.F.F. 2'x 4'x 3/4" TELEPHONE BOARD AND'REGEPTAGLE (OR, FIELD VERIFY,RELOGATE EXISTIN(5) TO BE MOUNTED UNDER STEREO PLATFORM. GFRGUIT AS SHOWN. 15 ELECTRICAL POWER 015TRIBUTION LOCATION FOR STORE. SEE "PANEL SCHEDULE" AND "ELEGTRIGAL POWER\ DIAGRAM" FOR FURTHER INFORMATION. FIELD VERIFY EXAGT LOCATION AND-REQUIREMENT5. I6 AGGU UNIT (48OV., 30), WP 0I5G. SWITCH AT UNIT, CONDUIT 8 CONDUCTORS. REFER TO POWC'R'RISER DIAGRAM FOR ADDITIONAL INFORMATION. PROVIDE WEATHERPROOF GROUND FAULT INTERUPTER RECEPTACLE AT UNIT. (FIELD VERIFY EXAGT LOCATION) -7 HEATER (480V., 30), WP 015G. 5WITGH AT UNIT, CONDUIT $ GONDUGTOR5.REFER TO POWER -RISER DIAGRAM FOR ADDITIONAL INFORMATION. PROVIDE WEATHERPROOF GROUND FAULT INTERUPTER RECEPTACLE AT UNIT. (FIELD VERIFY EXAGT LOCATION) dKT N0. ELECTRICAL LOAD $UMMARY IU Voltage: DEOdRIPT10N A UAL dONNEdTED KVA POWER FAdTOR A UAL dONNEdTED DEMAND KVA N.E.C. dONNEdTED KVA 20/1 B/** N.D. . DEMAND FAdTOR N.E.C. FEEDER DEMAND KVA WOHTINd 6.608 1.0 6.508 6.608 1 2 1.25 6.885 REdEPTAduo 5.492 1.0 5.492 6.492 1.0 < 10 K* 0.6 QNDR 5.492 MOTORO 0.000 019 01000 01000 M 1.0 0.000 FIXED ELEd. 0PAdE HEATINd 0.000 1.0 0.000 0.000 All phaged to be balanced to within 7% 1.0 0.000 AIR dONDITIONINd OYdTEM 6.668 1.0 6.668 6.668 1.0 + 26% Ld MOT 8.067* ELE&Rld WATER HEATER 1.600 1.0 1.500 1.500 w� 1.0 1.500 HEATER 10.000 1.0 10.000 10.000 =�10 1.0 10.00D* TOTAI.d: 22.500 U E dREATER OF THD &TEIJORIIEd BRANdH dIRdU[T 22.600 22.600 N.n.d. DEMAND KVA x 1000 dYOTEM VOLTAdE x 1.73 23.877 KVA x 1000 480 x 1.73 23.877 =MIN FEEDER AMPd 28.8 AMPd dKT N0. WIRE OIZE Panel ID: A IU Voltage: 480 / OR , > 11- fS 12 GALE LT 20/1 B/** Location: UTIIdTY ROOM 1.404 U 3 0 Type Bncl,: NEMA 1 1 2 3 12 Mounting: OURFAdE 20/1 B/** 8 4 u Aid u 20/1 TOREFRONT LTO W 1 4 N W Main M 100 Am p N 0 c0 w N J u W-j�o M z = r4 All phaged to be balanced to within 7% uding actual connected loadd. LU w z z ul � 0.360 �LL All Circuit breakerd dhall be dtandard bolt -on type, unle�p noted otherwide. -- 20/1 RE EPTA d LE 12 Q M :1% w� MMa% N.E.d. A 'DUAL W UOQ .nzu = dna 1 =�10 �Q� • WIRE BRANdH dIRdU[T BKR BKR IAAD LOAD M M LOAD y BKR BRANdH dIRdU[T V ;0) M dKT NO. OIZE 0 Q Q �w� (KVA) (KVA) (KVA) U? OPTION z w M IZE j LIGHTING CODED NOTES �I 1.20V., 20 AMP CIRCUIT I J -BOX (OR REUSE EXI5TIN6) FOR STOREFRONT 516N. VERIFY EXACT LOCATION IN FIELD. FURNISH 015CONNECIT MEAN5 PER N.E.C.-RE6VIREMENT5. 5EE SHEET A-2 FOR FURTHER INFORMATION. 2❑ ANY/ALL EX15TIN6 LIGHT FIXTURE5 TO BE REMOVED. FINAL ELECTRICAL LAYOUT TO BE A5 SHOWN ON PLAN. ALL WORK INSIDE STORE SHALL COMPLY WITH LANDLORD'S SPECS. I. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND LANDLORD'S DESIGN CRITERIA. 2. THE CONTRACTOR 15-RE5PON51BLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING/ BIDDING WORK. 3. THE CONTRACTOR SHALL 5AT15FACTORILY'REPAIR/ REPLACE EQUIPMENT OR PART OF STRUCTURAL DAMAGED AS ARE501-T OF THEIR WORK. SURFACES AND FINISHED AREAS SHALL BE'RE5TORED TO MATCH ADJACENT AREAS. 4. APPROVAL SHALL BE OBTAINED FROM THE ENGINEER/ LANDLORD PRIOR TO GUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER. 5. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONGEALED IN FIN15HED AREAS EXCEPT A5 SPECIFICALLY 5HOWN/NOTED OTHERWI5E. 6. ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED PROM STRUCTURE. ACGE551BLE RACEWAY5, WIRE5, BOXE5, 5WITGHE5 AND OTHER ELECTRICAL ITEMS A550CIATED WITH TH15 WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. 1. WIRE SHALL BE'REMOVED BACK TO SOURCE PROM INAGGE551BLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. PLATE COLOR SHALL MATCH ADJACENT SURFACE A5 NEAR A5 P0551BLE IN FINISHED AREAS. 8. MODIFY AND REROUTE EXISTING WIRING A5 REQUIRED TO ACCOMPLISH INDICATED WORK AND CONTINUE SERVICE TO LOADS BEYOND AREA IN WHICH WORK 15 DONE. q. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING 5Y5TEM5 AS 5HOWNMOTED ON THESE DRAWINGS AND PER OTHER APPLICABLE DRAWING6/IN5TRUGTION5. SEE AIR CONDITIONING DRANN65. 10. ALL MATERIAL'REMOVED SHALL BE 1?I5P05ED OF A5 DIRECTED BY GLAIRE15 OR LANDLORD. II. ALL WIRING INDICATED A5 EXI5TIN6 15 BASED ON ORIGINAL CONTRACT DRAWINGS AND 15 TO BE VERIFIED BY CONTRACTOR AT JOB SITE. 12. WIRE 51ZE SHALL BE #12 THHN/THWN UNLE55 OTHERWI5E NOTED ON PLANS. CONDUCTORS #6 AND LARGER SHALL BE THW. 13. ALL CONDUCTORS SHALL BE COPPER. 14. ALL CONDUCTORS SHALL BE RUN IN CONDUIT (EMT OR RIGID). FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX, LENGTH 6-0". NO BX,YZOMEX, ARMORED GABLE, ETC. ALLOWED. 15. ALL MATERIALS SHALL BE U.L. APPROVED. 16. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB 15 COMPLETE DYZEFLECT ING ALL CHANGES AND ADDITIONS. GENERAL ELECTRICAL NOTES Il, ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 18. CONTRACTOR SHALL SEAL ALL FLOOR OPEN W-75 WITH A FIRE SEAL 51MILAR TO "OZ' FLAME5EAL. 19. CONTRACTOR TO'REMOVE AND/OR'REPLAGE CIRCUIT BREAKER5 IN EX15TINO PANELS TO OBTAIN AMOUNT REQUIRED A5 A MINIMUM PER PANEL 5CHEDULE. ALL EXISTING EXGE55 BREAKER5, IF ANY, TO'REMAIN A5 SPARES. 20. ALL NON -POWER RELATED WIRING IN CEILING AIR CONDITIONING PLENUM RUNNING WITHOUT CONDUIT SHALL BE TEFLON COATED CLASSIFIED FOR USE IN PLENUMS. 21. ALL NEW BRANCH CIRCUIT BREAKERS SHALL MATCH EXI5TING CONDUCTOR SIZE. IF GONDUGTOR SIZE 15 LE55 THAN CIRCUIT BREAKER SIZE, CHANGE CONDUCTOR TO MATCH CIRCUIT BREAKER. FOR EXISTING MOTOR, NOTIFY ENGINEER PROR TO'ROUGHING-IN. 22. ALL LOADS IN EXISTING PANELBOARD ARE ESTIMATED. 23. PROVIDE TRAPEZE HANGER A55EMBLE FOR PLENUM COMMUNIGATION GABLES WITH 3/8' DIAMETER. THREADED 'ROD AND CHANNEL ASSEMBLY TO SUPPORT GABLE BUNDLES EVERY 4 FT... O.G. (MAXIMUM GABLE5 TO BE PROPERLY STRAPPED WITH SELF-LOCKING GABLE TIES). EXP05ED CABLES 514ALL NOT LIE ON TOP OF CEILING TILE OR LUMINAIRES. 24. ALL DATA EQUIPMENT TO BE FED BY A DEDICATED CIRCUIT WHICH CONSISTS OF A POWER CIRCUIT THAT FEEDS TH15 TYPE OF EQUIPMENT ONLY WITH A SEPARATE GREEN DROUNDING CONDUCTOR CARRIED ALL THE WAY BACK TO THE PANEL TO BE CONNECTED TO THE 15MATED DROUNDING SYSTEM. 25. SEE ARCHITECTURAL DRAWINGS OR INFORMATION CONCERNING EXISTING CONDITIONS AND NEW WORK. 26. ALL EX15TING LUMINAIRES TO BE'REU5ED SHALL BE THOROUGHLY GLEANED AND RELAMPED. 21. ALL WIRING DEVIGE5 SHALL BE WHITE WITH PLASTIC WHITE COVER PLATES EQUAL TO LEVITON 53500 5ERIE5 (5WITGHE5); 5252 5ERIE5 (RECEPTACLES); 38000 5ERIE-5 (COVER PLATES). 28. ALL CONDUITS, CABINETS, PANELS AND OTHER EXP05ED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.G. 250 AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. 261. MINIMUM 51ZE5 OF GONDUIT5 SHALL BE 3/4' FOR EMBEDMENT IN CONCRETE AND 1/2" FOR ALL OTHER APPLICATIONS. 30. ALL DEVICES IN EXISTING WALL5 NOT AFFECTED BY NEW CONSTRUCTION SHALL REMAIN ACTIVE. 31. ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRINGS. 32. FU5E5 SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLE55 OTHERWISE NOTED. 33. A/C EQUIPMENT WIRING, BREAKER AND FUSE 51ZE5 ARE BASED ON AIC EQUIPMENT SPECIFIED ON CONTRACT DRAWINGS. CONTRACTOR 15 -RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSE SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENT5 IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS YELL AS ANY FEEDER CHANGES BEING AFFECTED BY TH15 CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 34. CONTRACTOR SHALL COORDINATE ALL THEIR WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER AND CONTROL CIRCUITS WIRING AND RACEWAY5 AS 5HOWN ON THE AIR CONDITIONING DRAWINGS OR SPECIFICATIONS IF AIR CONDITIONING DR44IN65REFER TO THE MANUFACTURER'S WIRING DIAGRAMS, THE CONTRACTOR SHALL VERIFY WITH SAID MANUFACTURER ALL REQUIREMENT5 AND INCLUDED ALL'RELATED WORK IN THEIR CONTRACT. 35. ALL LUMINAIRE5 SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REGUIREMENT5. 36. RI5ER5 ARE DIADRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUtRED FOR THE INSTALLATION, 31. TH15 DRAWING 15 A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR 15-RE5PO%113LE TO PROVIDE A FUNCTIONING SYSTEM. 38. ALL GABLES SHALL BE'RUN WITHOUT SPLICES EXCEPT WHERE OTHERWISE INDICATED. 3q. ALL PULL AND JUNCTION BOXE5 SHALL BE ACCE55ABLE AT ALL TIMES. 40. EXACT POINT METHOD OF CONNECTION SHALL BE DETERMINED IN FIELD. 41. ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 42. ALL RACEWAY ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR CODED AS FOLLOWS: 1201208V SYSTEM 2111480V SYSTEM PHASE 'A' BLACK PURPLE PHASE 'B' 'RED BROWN PHASE 'C' BLUE YELLOW NEUTRAL WHITE DRAY DROUND GREEN GREEN 43. EXISTING F/A PULL 5TATION5 TO'REMAIN IN SAME LOCATION. MAKE ALLOWANCE FOR'REMOVING THE DEVICE, PROVIDE NEW PLASTER RING'REQUIRED FOR NEW RE5URFAGING AND REINSTALL IN PLACE. 44. EXISTING F/A AUDIO DEVICES THAT ARE LOCATED IN DEMOLISHED AREA TO BE RELOCATED A5 5HOWN OR A5 DIRECTED IN FIELD AND CONDUIT AND WIRING EXTENDED A5'REQUIRED. 45. E.G. TO INCLUDE IN THEIR BASE BID CONNECTING TO EXISTING F/A SYSTEM PROVIDING AND INSTALLING REQUIRED F/A 5Y5TEM DEVICES WITHIN SPACE A5 -REQUIRED BY LOCAL AND MALL AUTHORITIES. LIGHTING PLAN SCALE: 1/4" = 1'-0" CLAIRE'S LIGHTING FIXTURE SCHEDULE 5YMB0L TYPE DESCRIPTION MANUFACTURER CATALOG # LAMPS VOLTAGE WATT5 COMMENTS a A 11' RECE55ED DOWNLIGHT AMERLUX VLFLIOM MHCIO/U/M/3K 120 18 CENTER 5ALE5 GENERAL ILLUMINATION O (VER5AL I TE) PHILLIPS T B 6"'REGE55ED ACCENTLIGHT AMERLUX TRMIOM/H MHGION/M/3K 120 l8 PERIMETER ACCENT LIGHTING FOR ® u (RECESSED TRANZFORMER) W PHILLIPS _U WALL5 NOT PARALLEL WITH GRID, PULL w J U M 'T cel Kto Z n (L W DOWN ONLY ENOUGH FOR PROPER Z wUr www 6, 9wo W w U IZLL Q AIMING, 6' ON CENTER, 5'45" FROM WALL ® EM 6'-RECE55ED EMERGENCY LIGHT LUXNET �RD015E IN INC 120 8 5ALE5 FLOOR EMERGENCY LIGHTING, _� _ w uOq F- Ln,nU w w Z LL RECESSED EXW EXIT, LED, ACRYLIC EDGE LIT, ATLITE 5WI6RCWH LEDs INC. 120 2 EXIT, FRONT ENTRANCE, REGE55ED INTO w a LnH WALL'REGE55ED LL cn Lu w� BACK VERTICAL SURFACE TO SOFFIT � w EXM EXIT AND EMERGENCY LIGHT COMBO A5TRALITE EEUURWEM LED/5-6W 120 14 EXIT AND EMERGENCY L6HT COMBO, UNIT WALL MOUNT O (on WALL MOUNT, STOCKROOM /'1 OLL_ G 4'2 LAMP STRIP MERCURY MM232 2-1=308/135 120 b4 SURFACE MOUNT IN STOCKROOM ;--� H 4'2 LAMP 5TAG6ERED STRIP MERCURY 5TA6232 2-F32T8/135 L20 64 WALL MOOTED BEHIND PERTMETER Q o��z 0 z W � - LLJ SLANTED MIRRORS, EACH STRIP TO USE 2 ---� ~ J W Li 0 OF 6 DIFFERENT COLOR SLEEVES ® L 'RECESSED FANLIGHT COMBO BROAN 661 52MB/CAP L20 14 BATHROOM LI6HT/FAN ® M 6' RECESSED DOIMILITE (5VA) AMERLUX FTRWWIOM/W MHGIO/U/M/3K L20 18 STORE FRONT 5OFFIT5 arch, prof t: PHILLIPS T N 6'Xl' 9EMI=REGE55ED WALL WASH AMERLUX CRAIOM/W MHGION/M/3K L20 l8 PERIMETER WALL WASH, 8' ON CENTER Q (GALVALETTO) PHILLIPS MAX. 4'-5" FROM WALL P TRACK FIXTURE (TRANZFORMER) ON AMERLUX TWW10/W/CA MHGIO/U/M/3K 120 18 TRACK INSTALLATIONS, IF CONTECH I CIRCUIT TRACK PHILLIPS REU5IN6 EXISTING TRACK, NEED MFG. NAME USED ON STRIP STORES d 'B'd'G" STORES ONLY R 2'X4' PRISMATIC LAPIN, 3 LAMP TS MERCURY 35E332ELB 2-F32T8/735 120 84 GEN ILLUM IN ORID GIELING, USED ONLY ON NON -PROTOTYPE 5TORE5 5 SPEAKERS, NORMALLY 2/5TORE GUAM 8CIOFECO, ER08�5 NONE 120 N/A RECESSED SPEAKERS SUPPLIED BY LIGHTING 5B2 MANAGEMENT W/ LTG. INSTALLATION OF SPEAKERS, SPEAKER WIRE AND RELATED CONNECTIONS ARE TO BE BY THE ELECTRICAL CONTRACTOR. NOTE: I. ALL LIGHTING 15 SUPPLIED BY OWNER. ANY MATERIAL REGARDING LIGHTING SHOULD BE DIRECTED TO LIGHTING MANAGEMENT, INC. 120 NORTH MAIN STREET, PO BOX 531, NEW CITY, NY 106156, PHONE: (845) 638-16150, FAX: (845) 638-Obbl, E-MAIL: LMICMAIL6AOLLOM, FOR ACCOUNT INFORMATION: KURT THOMAS, FOR CUSTOMER SVC: DYIAYNE LAW, FOR SHIPPING: CHRI5 HICKEY. 2. VOLTAGE: VOLTAGE FOR ALL FIXTURES 15 12OV. 3. ALL LOCAL CODES MUST BE ADHERED TO. THE CONTRACTOR MUST NOTIFY THE ARCHITECT AND LIGHTING MANAGEMENT OF ANY LOCAL'REQUIREMENT5, SUCH AS SEISMIC CONDITIONS, EXIT COLOR5, OR PLENUM-RATIN65 IF DIFFERENT THEN SPECIFIED ABOVE. NORMALLY 5TORE5 IN MARYLAND U5E GREEN EXITS. 4. FIXTURES WITH EMERGENCY BATTERY PACKS, ALONG WITH EMERGENCY LIGHTS AND EXITS, ARE TO BE WIRED TO N16HT LIGHT CIRCUIT. 5. NEW YORK CITY REQUIRE5 THE SUFFIX 'NY" BE ADDED TO THE FLUORESCENT, EMERGENCY t EXIT FIXTURES. 6. THE CONTRACTOR 15'RE5PONSIBLE IN'RECEIVIN6, HANDLING, MAINTAINING PROPER INVENTORY OF AND INSTALLING THE LIGHTING PACKAGE UNTIL THE STORE 15 TURNED OVER TO CLAIRE'S. ANY SPARE SHOULD BE MARKED 'SPARES" AND PLACED IN THE REAR AREA OF THE STORE. LMI 15'RE5PON51BLE FOR "MATERIAL' FOR ANY WARRANTYRELATE D 155UE5 FOR I YEAR, THE CONTRACTOR 151ZE5PON51BLE FOR THE "LABOR'. - ASTERISK INDICATES NO REVISION MADE TO THIS SWEET 91 r I I 0 a 0 a uju a 0 Q Z u u W N w _U w J U M 'T cel Kto Z n (L W w? Z wUr www 6, 9wo W w U IZLL Q � a q Cq ve in �a uj q U J O _� _ w uOq F- Ln,nU w w Z LL Cq V r- Ln o r cn 0 Q LL w a LnH LL cn Lu w� � w m �w3: cn IL IL C J LJ_J O (on /'1 OLL_ W U r__ 00(-) Q N LLnQwQ U Q o��z 0 z W � - LLJ Z ~ J W Li 0 - Q � Q u/ J U Q n U) U U revisions: checked by: PH JL drown by: PH STAFF dote: 4/23/04 sheet no: E 2-1 arch, prof t: - ASTERISK INDICATES NO REVISION MADE TO THIS SWEET 91 r I I 0 a 0 I MECHANICAL CRITERIA GENERAL J in Taranto drswkgs are id dearly shore ALL moffcetlom to awsdng installation that am required to ecoommodw Twnent Improvements. ❑ Tenant improvement HVAC documents shall be propared and stumped by a RegbWW Proftesianal Engineer. ❑ This document Is to be used as a dbddist to ve ft compliance with Mall Dsslgn Crltarie. ❑ Unless already e*fing and In compliance with LSMWd'e requirements. Teramt Is required to install, upgrade and/or furnish any and all equipment, dudwork, etc. forTenanls HVAC service Installation. ❑ The design, materials and hasfalation shag conform to the beet currant practice In the respective trades and shall be consbbent with good engineering pradia, moLffi urwo recknnrrlerd ions, Industry techntcsl f ew ei so and standards. In Any modification aw rvbso oonsbu a�n must reoel+re the prior wrftben approvalfhom the Landlord, priori drawing submholorL Upgrades shall be subject to wallsift. ❑ Modiflcalorne to adoft systems that are required to woon "n riots Tenant Improvements shall be dearly doNed In both In to written fmpx* for deviation and on the a tbuct documents, ❑ Any unused hvw equipmW4. ductwork, plMhIg. WMng, at within or serving the demised promises must be removed. STRUCTURE ❑ Locate RTU where designated by L wdlord or provide written doonmentation by a regbberod structural ergineerwhere ahlemab location les pr+opMed ora bastion Is unavailable. ® Wtbn requWW, Tenant shag provfde supplemental structural support f mag designed by a licensed sbnucbual engineer ermf>Ioysd by TwwA to adequately support to Tenors equipment The Landlord may require that engineering analysis, review or design be performed by Lardionfs erngl w at Tenant's expense. ❑ No aEbendiorm addluory twin iii con rite or rnodlllllailoi to Landlord's structure to accommodate Torwo work ahs# be per wined without obtaining Lancord's pr . written apprtwet. The Lsndbrd may require that approved structural modlbdalons be perfombd by tho Landlord'e contractor under oontraot to Tenent at Tenant's experes. ® Tenant shag not dr1l, saw weld or shoat Into Landlord's structure or structural rnerrrbw& All adochrwo shall be with beam clamps. We or bob With crashers. Dar not attach any construction dirscdty to Landfonfe roof deck. J*ti6 beams, busses and gindae may be used for lateral bsalig and spanning support. Do not support any construction Mom Landlord's era est ,oArp or bddgng. PROPERTY GROUP • SIMON M11 IK COY COMER P.O. BOX 7033 INDIANAPOLIS, IN 46201 ' (317) 636-1600 - ZriiylAl'TA 1 SPLIT SYSTEM UNIT In Telt d must Inaolporatis HVAC bid cab Win Indo their submission to Ctrs landlord. A farm has been provided on this sheet ler tenants who prohr not to pwb n mons detailed calculations. Al calculations shag be performed per ASHRAL Ej Unit must be stead appropelabefy to maintaln specs comfort. As a guldellne, the unit shall be sized for 90% to 110% of the calculated load. ❑ Tenant shag provide s now Woo unit(s) with the following eaoeptbra: ® Unit Is Was than 10 years old or ❑ Landlord has approved of the now of edetim Woo unk(s) in writing beton construction beglrs. ❑ Landlord will not consider permuting the reuse of eodstIng hvec unk(s) until its following has bw submitted by Tenant In writing: In A report on the capadty and ooncilion of the wbfng equipment by a company emplaft U tins osrtinsd refs lgeratbn epedaMsts. This report Mall include test data used in ow*rrsrg the equipmWo capabllties and shag be signed by the TwwA% Meotnmioel Engineer, indicating VW have reviewed the krlbrrna lon and find R accurate and the equipment SAM* fbr roues. ❑ Cantract docurrsnbs shag dsMcM a the rmftnUm pabli wx,s parsamabrs, neArrbishkg speolhtoalons and establish a verilloadon proosdurs, kwkx ig a report to be subrrrifieed to the Lendlad alter wok hoe been completed. in Cabinet shrill be constructed with gaMu*od double wall panels, with the beer Mold metal gran encapsuldirg is minkn um of 1•,,112 Ib. density Insulation. No insulation may be exposed b #0 airdroom. ® Aooses paroleand doors shrug be gesloMtsd. ❑ Candwmft dro pan shag be *W;m cleat, with a mastic coating on the revwse We to prevent swsaNg. ® Motae 112 HP and Largon &W be three phase. Wars shall be mounted inside the unlet owing. AM drives to be variable pitch, with rt�jnrfhble,lmObr base. 9wkW shall Fon 200' ,000 � p�sownot bloft paoo nib bwtrgs shag have soctandod lubndontba Was. ❑ Hees shag be supplied by an c Iectrfa heat will In the air a w idler or duct system, (If wulrodj Roc+lda with an hndepsndant dbcorneot wdiml. ❑ Revwe a oompuNr prtrMart c�apgtsy�etwm perlb no for Undlord rsvdew� ❑ Indicate cckumn guns doalpnatlaN an HVAC plan. ❑ Spe* brag guard an oondensng call. ❑ Tenant's HVAC o0nfra0tcr must Mabel all of to Twwft rodlfop equipment to ensure proper ldenigloadon. © Twnsrnt'a sgrripmwtt shag not bwwnalt vbration b the "ft M Ovide vb eft leclainfor ail apgt "Non ow Im ❑ Condensing unit shag be otee t to rodtalrucdurewAh ma wfort u+ed equipmsntsupport rags. Al mdvxxk shag be dons by to Larrdlordla rod N conbubr of Twwdb w cp ensu. MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS AND DETAILS. MEP -2 ELECTRICAL AND PLUMBING CRITERIA DOCUMENT CHECKLISTS AND DETAILS. MEP -3 SPECIALTY TENAT CRITERIA DOCUMENT CHECKLISTS AND DETAILS. ( ONLY WHEN REQUIRED AIR DISTRIBUTION ❑ All dui twolk shah be Qelvaftiaed eheeWoeftrl, deal mWl shop 1iaMOMW and installed to SMACNA standards. DucMaord Is not permitted, ® AN supply air ductwork etdwnaly shag be iraulabed with 1412" thidk foil fans kwulation. ❑ inbornaly Ned dudvr may be used fbr acoustic purposes only, NOT as a substitute for extemw ❑ Eklernaly Insulated fleodbie dud; not to wood S40" in length, may oniy be used for connection to supply dMW wL Flat duct shall be fastened to metal duct and dgfwerwlfh machanioaoytightened draw bands. ® halal volumaloorrtrol darn m ns on each duct to a dglUm. ❑ The haat gate ibm enclosed displaywlndo a must be ventilated. RETURN NR ❑ An open caging plenum return at eyetem shag be used. Dueled return system is not pemnitled eoocept at ftd tenants and aMrer odor produc ng iersnts cr ole deierrn hwd by dna Lordbrd, ❑ Provide rebm. / naMtgrlres. Stas atone square loot of grille for 800 ogme het clgross bwmhba anew. TOILET 00AW Tenant shag paovids a caging oft* %% with a bada3 . R damper shoed to overcome the reddonce of Tenant Ireballed components and ail du*mxk. Minimum duct ems shoo be 6' diameter. ® The WM room W switch (wllh delay ftwIf recd Wad) shell cc kb am the flan to provide irntwnftrrd opsnatio, ❑ Tenant shall use ea,b enlist exh uust duct where one erdsIL Bftust Syelerrs requiring continuous operation or exhaust requirements in excess of 150 CFM must be Ix vWed enth* by On Tenant and roused Independently b tins h Aft axis for. ❑ Where the Landlord antral iollst ad=* duct does not eodet tenant Shag dec�haarge dkeody to roof. Loosbe roof verrelreldn a mInimum of 10'tom any eodeft outdoor air nfokas or I i ill; Ws equiprmwrt kwalcrle. Gooseneck bps eoftwet dbsdtsrge In puahlb bmL Al rodwak associated with exhaust eaten shell be pabnod by i andWft designated rooter at Tenant's AIR siurwce ® Moorporals a Outdoor / stand ail bWwft surnmery alb design drawings. ' TWWt MON-00Y Dthe dlw& Pro*o a o«t balance * 1201101 Ch aarin pt b the Landlord when construction has been an rpk Isd. 021131%04 REFRIGERANT PIPING ❑ Rah mM pWg Baer be ACR copper ki til, deaned by menufscbw, suds capped. % ke sob' an not permitbed. ❑ Pipe hanger design shall prevent vbratkx fbm being transmitted to the buildim Wucbum ® Root -mounted piping shag to Installed on fres floaft prefabricated supports similar to Mlro model 24-R on we llway treed pada. Remove balled (stones) from beneath any mof support, The use of Wood for supports is prohWed. ® Al root pipe psnstnatlons shall be made through a pre -molded Aching, specifically manullactured for the mail's mdq sysWn% with a UV4%M neoprene or EPDM boot that corrtonns to the slue of the pips. FIsWo piping or conduit shag not pas thru roof ponbballoro or NasMriegs. ❑ Insulatereftipant pWq wAh plenum rented closed deg Irsulatim CONDENSATE DRAINAGE ® Corderaeate Dean end � aha/ les asppec. Condensate trap should beat a depth sulflolent 1b vvwwrw posbgwl negative static preoore onion V minknurn} ❑ Rout• rooftop unit condensate &IM ludo the building through a waterproof po whaadw In the We ofthe tenant's rooftop unit curb, dawn kb the tenant's lease space wWdischergs Into brand prodded Aoordrialn or a whore applicable Info a aondenesM main provided by the lrxdlord. ® Condensate drain piping shag be knwbe W and pipe instokla, Ad loo knduds a cleanout at each change In dhoolon. ODOR PRODUCiNG TENANTS on Tenants wdlh hbemaily gsraeratod odors a otter oon101nd, ea such ae ALL FOOD PREPARATM areas, Nei! SWw^ Hair Salons, Pot Stops, Photo Proceeoore; and others at the sole discrobn of the Landlord, Thal maintaln an exhaust air wabem stood for 50 cflrn per equars foot of atoreltont opening. Alae d the solyd emvilon of the Landlord, to exhaust air aystwn may be reduced to 25 oh *qusrs foot of otcwnfr No.. * pw" when a'buW of at lead 10 hot has en pm dud between any odor produolg elerr" within the ionm spew and the slashont opening. Thio buffbr ms0 be rely displays, moepdbn oountem or other sin ffar pen ownt sbrnende. ® Repkeemint (malts -up) air *4 bo dfaw*om mag Connnon Mea for extwid oystenno up b 2500 SCPM and from d Mosted makeup air w to for larger a tw* capadtiss. Total r�eplaarnerd air through moiosup air units and Outside elf dr+okgh the sircondltloning urd shalt be a minimum of 10% lase than the exhaust air quw*. ® Edeust CaioulMbn ler Odor Producing Tinanta Sba lont oprg 0r0CCFM / flrr7CF'M ❑ Tenant shag katag an Indicator pilot Mmp 12" above doll stratfor dao purpose of "N tug admust fan operation. ❑ odor eodneust and makeup air fano' opsrNion shag be W&KMS d"u"ng oocupisd hours. i MECHANICAL CRITERIA Split System -Standard Checklist HVAC CONTROLS Control systSm ahoy employ a sewn day tuneable or programmable thermostat to aubomebe equiliment operation. Supply fan operation shall be oontlnuous during occupied hours. ❑ Controls shall provide for closure of outside air dampers when farm are off to prevent uncontrolled knfbgratlon of air. The outaide air dempor shall be opened during occupied operation. I CONTACT INFO For questions regarding site access, ekwafront & TE E architectural crkeft, engineering design, delivery dates, LAY RRAC construction noes & regulations, the scope of Landlord's and Tenant's Work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call 317-636-1600 for asslstalnce. Carmel, Indiana 46032 MEP -1 0 0 0 0 r 0 0 0 ►N 0 HM.A.C. CALCULATION FORM SPLIT SYSTEM SPECIFICATIONS 'PLENUM SENSOR MANWACTUNR MATURATED SUCTION TEMP..... R5MQERANT E.ER RATING SATURATED COND. TEMP . ,AIR ENTERING COND _ J;db COND"H2 UNR R"Mopme; Nmmrm MODEL N0. MODE. N0. MODEL NO. WEIGHT' WEG AIRPhre-MI -Feb VO�TBIPrMSEM VOL AIR L Fdb�Fwb E.E.R. RATING TOTAL. ROWS_ RC FINS..,, COMP. PWR NPUT KW. TOTAL STATIC PRESSURE _„ W.G, TOTAL. COOING STUN TOTAL COOLING BTUH FAN DATA,---- RPM _ _ _ NP,,.._,_BHP SENSIBLE COOLING UH PRESSURE DROP 'WC ggpro COIL. FACE AREA SOFT. FACE VELOCITY _ FPM LOW LEAKAGE SEALS ON OA DAMPERS ❑ LOW VELOCITY FILTERS ❑ ECONOMIZER In (YES) ❑ (NO) OR LOW AMBIENT CONTROL TO 09F ❑(YES) ONO) REMA IM 1 IL TOTAL SENSIBLE HEAT GAIN: SPACE 8"BLE + PLENUM SM113LE 20703 STUN 14. TOTAL HEAT GAIN: TOTAL SM113LE TOTAL LATENT $2233 BTUH I&AIRQUANW. SPACE SENSIBLE 16282 ErrUH '10. HEATING MIK FtECfD.'. RECIRCULATION CFM X IAXX20 S 837 x 1.00 x 20 &T 5297 KW 3413 BTUKW 3413 BTU/KW (CLTEYSICLPS) FROM ASHRAL DEFAULT AL DATA, WMERE TENANT CHOOM TO NOT PROVIDE MORE ACCURATE CALCULAMONS ARE 18 SHOWN IN PARENTHESES I CONTACT INFO For questions regarding site access, ekwafront & TE E architectural crkeft, engineering design, delivery dates, LAY RRAC construction noes & regulations, the scope of Landlord's and Tenant's Work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call 317-636-1600 for asslstalnce. Carmel, Indiana 46032 MEP -1 0 0 0 0 r 0 0 0 ►N 0 SPLIT SYSTEM SPECIFICATIONS MANWACTUNR MATURATED SUCTION TEMP..... R5MQERANT E.ER RATING SATURATED COND. TEMP . ,AIR ENTERING COND _ J;db COND"H2 UNR AIR HANDLING UNIT EVAPO RATOR COIL. MODEL N0. MODE. N0. MODEL NO. WEIGHT' WEG AIRPhre-MI -Feb VO�TBIPrMSEM VOL AIR L Fdb�Fwb E.E.R. RATING TOTAL. ROWS_ RC FINS..,, COMP. PWR NPUT KW. TOTAL STATIC PRESSURE _„ W.G, TOTAL. COOING STUN TOTAL COOLING BTUH FAN DATA,---- RPM _ _ _ NP,,.._,_BHP SENSIBLE COOLING UH PRESSURE DROP 'WC ggpro COIL. FACE AREA SOFT. FACE VELOCITY _ FPM LOW LEAKAGE SEALS ON OA DAMPERS ❑ LOW VELOCITY FILTERS ❑ ECONOMIZER In (YES) ❑ (NO) OR LOW AMBIENT CONTROL TO 09F ❑(YES) ONO) REMA IM I CONTACT INFO For questions regarding site access, ekwafront & TE E architectural crkeft, engineering design, delivery dates, LAY RRAC construction noes & regulations, the scope of Landlord's and Tenant's Work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call 317-636-1600 for asslstalnce. Carmel, Indiana 46032 MEP -1 0 0 0 0 r 0 0 0 ►N 0 NA IN ELECTRICAL NOTES ELECTRICAL LOAD SUMMARY INDEX°"070M1 MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS MEP-2EL�ECTRICALAND PLUMBING CWTERIADOCUMENT CHECKLISTS AND DETAILS. MEP -3 SPECIALTY TENAT CRITERIA DOCUMENT CHECI4.13T'3 AND DETAILS. (ONLY WHEN REQUI ELECTRICAL/PLUMBING CRITERU Standard Checklist CAR1v�L - 1NDYANA GROUNDING GENERAL Tenants drawings are to de" show ALL modlflcetlone ® Grounding must be to binding steal with axodM* to existing installation that are required to accommodate weld or split bolt connection. Do not ground to cold Tenant Improvements. water pipe. ® Tenant improvement electrical documents shall be prepared and stamped by a Registered ProfouWal TRANSFORMERS Engineer. • ® All transformers shag be 3 phase. Single phase This document is to be used as a checklist to verify transformers are rot permitted. I compliance with Mall Design Criteria. 30 KVA and smaller tranatormer may be suspended �] Unless already existing and in compliance with from LwWlonft roof structure. Landlord's requirements, Tenant is required to install, upgrade and/or fumish any and all equipment, wiring, Mount transformer on vibration isolators. conduit etc. for Tenant's electrical and telephone service Installation. CONDUIT AND WIRING The design, materiels and installation shall conform to the best cunent practice In the respective trades and 0 All wMng must be in condult. All conduits shall be shall be consistent with good engineering practice, concealed whom possible. manuhraaura's recommendations, Industry tschril al references and standards 0 Flexible oonduft shag be MC only. Any mod{ficatbrn or upgrade of existing base building 10 Flexible conduit is not permitted within demising want services or construction must receive the prior written approval from the Landlord, prior to dmWng submission. Exposed conduit shall be installed in straight tines, Upgrades shall be subject io avalabigty and based upon parallel with or at right angles to the building structure. a Justified need. Do not loop excess flexible conduit In calling space. ® Modifications to existing systems that aro required to ® Wire shag be copper THHN or THWN wah Insulation. accommodate Tenant Improvements shag be dearly defined In both M the written request ler deviation and ® AN wbing shag be color coded per the moils current on the contract documeift lobeft standard, or as fbecws: Modifications and final connections to existing Landlord 2001120 volt systems: 277/480 volt systems: systems shall be performed by a contractor designated Phase A - Bleck Phase A - Brown by the landlord at TenanyS expanse. Phase B - Red Phase B - Orange Phase C - Blue Phase C - Yellow Tenant may or may not be a customer of the Utility Neutral - WIft Neutral - White with Company, however the design should be executed as If tracer or gray Tenant was squiring power directly from the Utility Company. Onty one connection to the Landlords chilled water males Is pemrilted. HVAC WIRING Temporary power will not be provided. Tenant Tenant shag provWs a main dlsoonnscting means at contractor must Install permanent feeder conductors each HVAC unit from the Lendlo d's service distribution point Immediately ler use as the source of light and power Rooftop units and exhaust Hans, If required, are to be during oonstructfon. wined through thelr roof curbs If so deslgnod, or udlfm factory fabricated roof piping curbs. Pitch poolosts are Any unused electrical equipment, conduit, wiring, etc not permitted. within or serving the demised premises must be removed. ® A 110 volt, duplex outlet dues be Installed liftin roach Reuse of all or part of existing equipment Is subject to of the HVAC unit. the field verification of the capacity and condition of the components. Contract documents shag provide SERVICE ACCESS minimum performance parameters, refurbishing specifications and establish a verification procedure, ® AD electrical wont shag be installed so as to be readily lndudktg a mandatory written report. This report rattail ope+g� servkdng, nhalntalrlg and detall Inspection and service to be performed, repair repaking. reporting procedures, additional re 6, and perfo"escue test results' Copes of fold vedficafion report shall be submitted to the Landlord to validate FLUORESCENT LIGHTING reuse. Exposed fioueacent tubes or fbctures with p uicubs, or prismatic lames ars not pa --%1 d in public areas. PANELS Ballasts shag be high power fladw, electronic with CBM En Tenant shag provide service sizing coWdatiorn by filling or ETL label and have a THD of + 20%. W form on this drawing or other sbmlar summary torn. AN aftlatIM shdl be per NEC. Qn Tenant sham provide a detansd onegne diagram, deplctIM oil existing conditions and new work to be performed. Tenant shag provide a main disconnect means wkhkn the leased space. Ciro* breakers shag be bolt --on, not plug4n type. Arrange bad to maintain a balance between phases of 10% or less. ® Tenant shag have bmaker locks on control and timedock crcults. Switching duty breakers on all devices used for turning loads ordoff. ® 24 -Hour/? -Day Time Clock is required to control storefront entry lights, show window lights, show window neceptades,and storefront signage. ® Electrical devices, timo4ocks, panels, cabinets, etc. shall be mounted on a plywood backer -board. Condult by landlord Conduit wlth wIm by ierrattt puilwim fortenant's communication wnnecdors. Condult with pullwire for tenses r —1--7 pow�sr �xrnnecdone. F 7.1— red Switchboard Tenant's o fi� 8{ 1 Fusible Switch or 11 ® (I Breaker 71— Q -inbhod Grade. 1r ..__. Wimway — ( `I disoorrned Switch. ater, only where the Coordirabs with field representaft tenant Is customer of for boation mletiw io rnstsr. the Utility Company. NOTE: 1. Ibis detail Is provided to Identify some of the condgisor s found In the flel 1. Terwnt shag field verity actual conditions prior to submitting documents. 2. Loc eftn of existing service Is to be determined by Tenant In the field. 3. Tenant shati obtain available fault current data from the utility company. Tenant's engineer shag specify appropriate AIC rating for tenant panel. Partial Riser Diagram PLUMBING GENERAL ® Tenant'& drawings are to alserly show ALL modlfintim to existing installation that are required to accommodate Tenant improvements. 0 Tenant improvement plumbing documents shall be prepared and stamped by a Registered Professional Engineer. ® This document Is to be used as a checklist to verify compliance with Mall Design Criteria Unless already existing and In compliance with Landlord's requirements. Tenant Is required to install, upgrade and/or furnish any and all equipment, piping, etc, for Tenants plumbing installation. The design, materials and Installation shall conform to the beet current practice in the respective trades and shag be consistent with good engineering practice, rwnufacturoes recommendations, industry trechnkmJ roferenoes and standards. ® Any modlflcattbn or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades sham be subject to avatlaWlIty. Modnztk s to existing systems that are required to accommodate Tenant improvements shall be dearly defined In both M the written request for deviation and on the contract documents. �] Tenant sham provide sw t gMmt riser diagrams as well as water piping riser diagram on design drawings. ® Only one connection to the Landlords sanitary and domesthc water mains Is permitted. Tenants Shan conned to existing vent header If existing, or extend vents thw roof. All roofing work must be by Landlord's roofer at Tenants expense. Domestic water is supplied at the pressure available from the utility minus piping pressure losses to the point of connection. Tenants requiring specific pressures should test the avallable pressure and install regulators or booster pump systems to mast their needs. Any unused plumbing equipment, ductwork piping, wiring, ato within or serving the demised promisee must be removed. FIRE PROTECTION ' PIPING MATERIALS j ® Below ground waste and vent ahall be amlosrw+rlght cast iron or schedule 40 PVC. All no -hub connections shall be with cast lron couplings, similar to "MG" couplings Including to In to Landlord main. Stainless steel band no -hub connections are not permitted below ground. Above ground waste shall be service weight cast iron. Above ground vent shall be cast Iron or Schedule 40 gahranixed steel. PVC piping Is not permitted above ground. Below ground no Joints below water unbe type (om) cope Above ground water shag be type V copper. LOCATION of PIPING Jp m plumbing equipment shall be property suspended from Landlord's structure. AN floor mounted equipment (water heaters, sic.) shag impose a floor bad no greater than 75 pef. ® No sanitary, vent, water or gas piping will be permitted within the Demising Walls. ® Hinged access doors must be Installed to provide access to all Plumbing egctpment Including but not limited to; valvee, deanouts, meters, and Indirectly connected piping or as designated by the Landlord. GENERAL (n Tenant's drawings ars to dearly show ALL modifications to existing lnategeticn that aro required to a0oornrrnodate Tenent Improverna ts. Tenant Improverrnent fire pi oteotlonn documents shall be prepared and stamped by a Certified 8prfnkW Designer or Registered Prof eelonal Engineer. ® This document is to be used as a cdwcldlat to vergy compliance with Mag Design Olbert&. Unless shady existing and In compliance with Landlord's requirements. Tenant Is required to install, upgrade and/or furnish any and all equipment piping, eta for Tenant's fire probaction Mian. The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturers recommendations, Industry technical referenoes and standards. Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawring submission,. Upgrades shag be subject to avallablgty. .•+ii- - - [MON PROPERTY GROUP 'DWV, pIY CES P.O. BOX 1033 )IANAPOLIS, IN 46207 • (317) 636-1600 ELECTRICAL LOAD SUMMARY INDEX°"070M1 MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS MEP-2EL�ECTRICALAND PLUMBING CWTERIADOCUMENT CHECKLISTS AND DETAILS. MEP -3 SPECIALTY TENAT CRITERIA DOCUMENT CHECI4.13T'3 AND DETAILS. (ONLY WHEN REQUI ELECTRICAL/PLUMBING CRITERU Standard Checklist CAR1v�L - 1NDYANA ALL - ON THIS CALCULATION FORMPER LIGMNG DEMAND - • • 1 � TO USED IN H.VAC. Condult by landlord Conduit wlth wIm by ierrattt puilwim fortenant's communication wnnecdors. Condult with pullwire for tenses r —1--7 pow�sr �xrnnecdone. F 7.1— red Switchboard Tenant's o fi� 8{ 1 Fusible Switch or 11 ® (I Breaker 71— Q -inbhod Grade. 1r ..__. Wimway — ( `I disoorrned Switch. ater, only where the Coordirabs with field representaft tenant Is customer of for boation mletiw io rnstsr. the Utility Company. NOTE: 1. Ibis detail Is provided to Identify some of the condgisor s found In the flel 1. Terwnt shag field verity actual conditions prior to submitting documents. 2. Loc eftn of existing service Is to be determined by Tenant In the field. 3. Tenant shati obtain available fault current data from the utility company. Tenant's engineer shag specify appropriate AIC rating for tenant panel. Partial Riser Diagram PLUMBING GENERAL ® Tenant'& drawings are to alserly show ALL modlfintim to existing installation that are required to accommodate Tenant improvements. 0 Tenant improvement plumbing documents shall be prepared and stamped by a Registered Professional Engineer. ® This document Is to be used as a checklist to verify compliance with Mall Design Criteria Unless already existing and In compliance with Landlord's requirements. Tenant Is required to install, upgrade and/or furnish any and all equipment, piping, etc, for Tenants plumbing installation. The design, materials and Installation shall conform to the beet current practice in the respective trades and shag be consistent with good engineering practice, rwnufacturoes recommendations, industry trechnkmJ roferenoes and standards. ® Any modlflcattbn or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades sham be subject to avatlaWlIty. Modnztk s to existing systems that are required to accommodate Tenant improvements shall be dearly defined In both M the written request for deviation and on the contract documents. �] Tenant sham provide sw t gMmt riser diagrams as well as water piping riser diagram on design drawings. ® Only one connection to the Landlords sanitary and domesthc water mains Is permitted. Tenants Shan conned to existing vent header If existing, or extend vents thw roof. All roofing work must be by Landlord's roofer at Tenants expense. Domestic water is supplied at the pressure available from the utility minus piping pressure losses to the point of connection. Tenants requiring specific pressures should test the avallable pressure and install regulators or booster pump systems to mast their needs. Any unused plumbing equipment, ductwork piping, wiring, ato within or serving the demised promisee must be removed. FIRE PROTECTION ' PIPING MATERIALS j ® Below ground waste and vent ahall be amlosrw+rlght cast iron or schedule 40 PVC. All no -hub connections shall be with cast lron couplings, similar to "MG" couplings Including to In to Landlord main. Stainless steel band no -hub connections are not permitted below ground. Above ground waste shall be service weight cast iron. Above ground vent shall be cast Iron or Schedule 40 gahranixed steel. PVC piping Is not permitted above ground. Below ground no Joints below water unbe type (om) cope Above ground water shag be type V copper. LOCATION of PIPING Jp m plumbing equipment shall be property suspended from Landlord's structure. AN floor mounted equipment (water heaters, sic.) shag impose a floor bad no greater than 75 pef. ® No sanitary, vent, water or gas piping will be permitted within the Demising Walls. ® Hinged access doors must be Installed to provide access to all Plumbing egctpment Including but not limited to; valvee, deanouts, meters, and Indirectly connected piping or as designated by the Landlord. GENERAL (n Tenant's drawings ars to dearly show ALL modifications to existing lnategeticn that aro required to a0oornrrnodate Tenent Improverna ts. Tenant Improverrnent fire pi oteotlonn documents shall be prepared and stamped by a Certified 8prfnkW Designer or Registered Prof eelonal Engineer. ® This document is to be used as a cdwcldlat to vergy compliance with Mag Design Olbert&. Unless shady existing and In compliance with Landlord's requirements. Tenant Is required to install, upgrade and/or furnish any and all equipment piping, eta for Tenant's fire probaction Mian. The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturers recommendations, Industry technical referenoes and standards. Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawring submission,. Upgrades shag be subject to avallablgty. .•+ii- - - [MON PROPERTY GROUP 'DWV, pIY CES P.O. BOX 1033 )IANAPOLIS, IN 46207 • (317) 636-1600 ! i`!�' � ' � ,� :� .;� ;�.•�0.. ;Aha,��: INDEX°"070M1 MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS MEP-2EL�ECTRICALAND PLUMBING CWTERIADOCUMENT CHECKLISTS AND DETAILS. MEP -3 SPECIALTY TENAT CRITERIA DOCUMENT CHECI4.13T'3 AND DETAILS. (ONLY WHEN REQUI ELECTRICAL/PLUMBING CRITERU Standard Checklist CAR1v�L - 1NDYANA PIPING COMPONENTS �] Ali connection to Landlord's cold water main le to Include a service Isolation valva Any and all piping not reused, serving the demised Promises must be removed. Q, Insulote all hot water, void wager, and condensate drain piping. ® Tenants shale provide at least one, fug sine, cleonout In toilet and kitchen areas. Cleanout may be wail or floor type, but must be accee6ible from within the Tenant's 613808. One floor drain must be Installed In toilet moms and other locations that may be exposed to liquids, such as food service arses. Ali floor drains must he" trap primer& ® Interceptors and separators shag be provided to prevent the discharge of oil, grease, hair, coffee granules and other substances hamtnul to the building's drainage gym. Refer to Criteria Drawing MEP -3 for further requirements. Moo4stbns to existing systems that we required to acconxmodate Tenant improvements shag be dearly defined In both In the written request for deviatlon and on the contrail documents. Only one connection to the landlord's fire protection main is pondtted. Any unused fire protection equiprnent, piping, etc within or serving the demised premises must be removed. Reuse of all or part of ex ie ft equipment Is subject to the field verification of the capacity and condition of the components. Contract documents shag provide minimum performance parameters, refurbishing speciftkaft and establish a verification procedure, including a mandatory writlen report This report shall detall inspection and servloe to be performed, repair reporting procedures, additional recommendations, and performance test results. Copies of field verification report shall be submitted to the Landlord to validate reuse. WATERPROOF MEMBRANE J ® If the Premises concxeie slab is not on grade, Tenant shall Install a waterproofing bonier membrane, in accordance with Landlord's specifications, in all areas that may be exposed to fluids or liquids Including, but not limited to, restrooms, food preparation and service areas, laundry and dry cleaning areas, and photo processing areas. All floor pipe penetrations, cle,anouts, and floor drains must be sealed watertight with membrane and flashing extended Into clamping collar, per ufscturses specificatlona. Refer to Architectural Criteria WATER HEATERS Qn Storage type water heaters shall be installed with relief valves and drain pans discharging to a floor drain. Qn Instantaneous water heaters are only aooeptabie If they do not substantially Impact the Tenant's electrical service. ® Ali water heaters 314W1 and larger shall be 3 phase. Shock absorbers, thermal expansion tanks, and vacuum breakers shall be provided In accordance with good engineering practices. �] Natural gas wafter heaters are not permitted except where written approval from Landlord has been granted prior to drewing submission. WATER METERS 10 Where tenant is not a customer of the utility company, all Food Tenants and other heavy water users shag provide a Rockwell or equal, utility grade water meter to be bath directly read and indirectly read via remote reader. Q] Metering assembly to be property located and adequately supported to allow for easy reading, maintenance, repair and replacement ® The meter and checks shall be aorxaaslble for maintenance and reading without removing the device from the line. ® Where tenant In not a customer of the utility company a double check valve assembly Is required. GAS SERVICE (where available) ® Tenant is responsible ler coordinating available capacity, pressure, service connection, and meter Installation with the Landlord and the local Welty. Ag piping shall be finished with a rust Inhibtf m primer, color coded finish, and identification labels. ® Gas meter by tenant at tenant's expense, Instal{ per utw company requirements. Simon Property Group requires all tenants to use SimplexGrinnell for all fire protection work. Tenant or Tenses General Contractor is required to contract with (and pay for) all tenant sprinkler work directly with SlmpiexGrinnell, For pricing and scheduling call SlmpiwGrinnsg Representative, 0800-204377 (ed. em8 AN shut -downs must be scheduled with Landlord Fire protecdor system shall be dhanged and operable when contractor's not on site. Sprinkler heeds to be quick response type rated for 165F. CONTACT INFO q 9a For questions regarding site access, storefront & CLAYTERRACE .� architectural criteria, engineering design, delivery dates, consbuc:tion rules & regulations, the scope of Landlord's , and Tenant's work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call 317-636-1600 for assistance. I Carmel, Indiana 46032 MEP -2 Ili Ile lti B B r j SPECIALTY USE TENANT CRITERIA ODOR PRODUCING TENANTS ® Tenant with Internally generoted odors or other contaminates such as ALL FOOD PREPARATION areas, Nail Salons, Hair Salons, Pet Shops, Photo Processors, and others at the sole discretion of the Landlord, shall maintain an exhaust air system sized fir 50 cfm per square foot of storefront opening. Also at the sole dsam*m of the Landlord, the exhaust air system may be reduced to 25 cfm1equare foot of storefront opening when a "buffer" of at least 10 feet has been provided between any odor producing element within the tenant space and the storefront opening. This buffer may be retail displays, reception counters or other similar permanent elements. Replacement (make-up) air shaft be draw from mail Common Area for exhaust systems up to 2500 SCFM and from dedicated makeup air units for larger exhaust capacities. Total replacement air through makeup air units and outside air through the air conditioning unit shall be a minimum of 10% Leri then the exhaust air quantity. Exhaust Calculation for Odor Producing Tenants: S'borshont opng Q ir (x) [DCFM / M = =CFM Tenant shall Install an Indicator pilot lamp 12' above them*etst for the purpose of verifying exhaust fen operation. Odor exhaust and makeup air fans' operation shall be continuous during occupied hours. .. REPLACEMENT AIR (MAKEUP AIR) ® The makeup air shail be heated and al"onditioned when introduced into public aress. In non-publio ansae, the makeup air shag be heated to a minimum of 4WF. Replacement air units shall be Installed on full perimeter curbs, similar to packaged Rif S. Interior make-up air ductwo* shall be wrapped with 1-112, thick, tbp-f' od, fiberglass Insulation. Al supply air diffusers within 10-0' of any hood shall be adjusted or designed to blow air away from the hood. SANITARY WASTE SYSTEMS Grease Inwoopptors, lint traps, and soBde interceptor* shall be Installed on any plumbing fixtures that have the potential off Introducing grease, Ink hair, ebur Into the building sanitary system. Tenants shall not dispose of any hazardous dwnlmfs Into the building sarnitary system. Photo Processing Tenants, ti necessary. Shall install an approved system for silver recovery. Locate all interceptors to allow adequate actress for cleaning and maintenance. GAS SERVICE Tenant is respornatble for coordinating available capy, pressure, *Woo connection, and meter Installation with the Landlord and the local uft. Ali piping shall be finished with a rust Inhibitive prkner, color coded finish, and identification labels. Gas meter by tenant at tenant's expense, install per utility company requirements. WATER METER Tenant is responsible for coordinating available capacity, pressure, service connection, and motor installation with the Landlord and to local utility. Al piping shall be finished with a rust Inhbtive primer, color coded finish, and identification labels• Gas meter by tenant at tenant's expense, install per utility company requirements. SIMON PROPERTY GROUP N00K COY CENIOi P.4.80% 7111333 INDMAPOLIS, IN 46207 :Y (311) 636-1600 PIPES ON ROOF Roof-nounted piping shall be matted on fra fioatlfng, prefabricated supports similar to Miro model 24-R on walkway tread pads. Remove ballast (stones) from beneath any roof support• The use of wood for supports Is prohibited. All roof pipe penetrations shall be made through a pre -molded flashing, spocific ally manufactured for the mail's rooling system, with a LN -stable neoprene or EPDM boot that conforms to the size of the pipe. Flexible piping or conduit shall not pass thru roof penetrations or flashings. MAINTENANCE The Tenant is required to obtain a formal maintenance contracts with Maintenance Contractors approved by the Landlord for the Inspection and cleaning of the following systems: Odor exhaust fan Grease exhaust fan and fan grease trap Grease guard system Grease exhaust hood and filters Grease exhaust duct. Grease interceptor } The Tenant must submit proof to the Landlord that contrricts have been executed and thewsystems are maintained as desctibed in this document. MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS AND DETAILS. MEP -2 ELECTRICAL AND PLUMBING CRITERIA DOCUMENT CHECKLISTS AND DETAILS. MEP43 SPECIALTY TENAT CRITERIA DOCUMENT CHECKLISTS AND DETAILS. ( ONLY WHEN REQUIRED SUPPLEMENT FOR FOOD SERVICE TENANTS GREASE EXHAUST SYSTEMS j M new or renovated spasms must comply with wrw Criteria and Codes. Grease exhaust fans shall be designed to be roof mounted directly on top of the exhaust duct In an upblost configuration. Utility set or %quirrel cage" type fans are prohibited. Fans are to be UL listed for grease and be provided with a drain that allows for single point drainage of grease, water and other residues. The drain shall empty into a weatherproof grease containment system, either a bWW grease trap as manufac bzW by Greenheck or mftlning an spadtlly engineered absorbent materiel sknUw to Grease Twn*m for 2 as manufactured by the Loren Cools Co. The roof area around the othaust fan shall be protected with a Gresse4k and G-, grease oolection system, as manuttotumd by Fedlteo Co, par +stlon,1-80a2544M The grease baploontainment system and Gram Guard must be cleaned or replaced monthly, or more frequently as established by the Maintenance Contractor or Lanidlud, by a Maintenance Contractor approved by the Landlord, Fan base shall be hinged to allow easy access for duct cleanup end have a safety chain or able to prevent fan housup *am damaging the roof when fan is hoped open. Lower Level Tenants, to mulWevet main must have vented curb exional"a Al fen dtechergss alai be 40' above adjoining surfaoss, and a mkftm of 10'-0' from intakes, buldkre, or roof edges. Al grease ductwork must be tested to 1-1/2` positive pressure, and demonstrated to the Landlord's representedlve to have no loss in pressure alter 10 minutes. Installation shallnot proceed beyond this print until this test has been verified by the Landlord's rep s"It ativs. UnobstruMd scoess panels In ductwork are required at each ahan0e In direction and as required to clean the entire isrngfln of the ductwork. Access penal locations shall los approved by the L andlonfe isix nttivs arnd/or the local suit ft. Access panels shall be gasketed'grea ss-ttglnt", and be of the sums, black iron material as the ducMrorL Geirantrd, double wall, or other comf6d alr am- ro i access doors shed not be used. Alter pneaetms testing and inspection by the Landlord's and the local authority, the duc work shall be wrapped with fireproof krsufation UL Rated as a Iftw separation for kitchen oftust applicatiote. Tenant shin have inspections and dowing porforrned *wt*, or mora frequency as eatsbRehed by the IiMiutenanos Contractor or Landlord, of 6* grease semust ductwork, rims, Sters, and acoesecries as raquYad to minwn or"" docharp to the Mcf. GREASE HOODS _ ® Comparrating and short circuit hoods are not permitted. They Introduce outdoor air directly Into the hood which has been A n onstrated to kntenvpt elfldernt capture of cooking Burnes. Hoods shall beer cu wd (20M. or lalso UL 710 Label for Type 1 hoods. Labels and Listings prior to 2002 are not scamprble, Lsndkmd will not consider permitting the reuse of existing grease hoods until the following has been submbsd by Tenant in writing: - A report on the cape city and condition of the existing equipment signed by the Tenard's Mechanical Engineer, indicating they have reviewed the I hwaillon and find it accurate and the egclpment sutieble for reuse. This report shall Include test data used in confim*ig the equipment's capabilkiee, a statement of oonflmusflon the hood is not a compsnseting or short circ It design and been a UL 710 MM dated 2002 or later. 1 GREASE HOODS (CONTINUED) j Where feasible, partial or full and panels shall be Installed an the open ends of the hood. All Island type hoods shalt have a minimum overhang of 12" on any open sides rather than the fr code minimum. Hood systems shall include gram extraction filters similar to Grease•X-Tractor filters as manufactured by the greenhedk Fan Corporation, (715) 355.8171 or KSAtnutti`cycione filters by Halton Mfg. (270) 237-0800. Standard, baffle type fitters aro not aooepbabie. DISHWASHER EXHAUST in DWwiashor th must be captured by a hood. An exhaust e at eme oefiing Is not acoepieble for this purpose, Hood and ductwork shall be constructed of aluminum or oWnl#m steel, and be watertight Pftoh ductwork and hudell joints in such a manner to allow moftre to drain back to hood or drain. DISHWASHER EXHAUST - _- Do not conned hemi wash *IM toilet room fixtures, or garbage disposals to the grease interceptor. Grease interceptors shall be sited as required by Local Budding Codes and as required by the Landlord. Sizing ceia:iatione shall be submitted b the Landlord for approval pew to oonstruoflon. Grease Interceptors may be Installed above the floor where #hey rec" the discharge flom only one sink. Al other grease producing tsunamis shall instal either a recessed interosptor, when the Tenant is on a sleb•on•grade, or a remotely located interceptor in a location approved by the Landlord. The *tenant shag educate his employees to the problems which can occur by improper disposal of gr=ja in the sanitary waste system. These include: clogged waste Ibm, fines (from 301096 authorltyk and irate:sed makftnanoo cost. Poet "NO GREASE' signs over each plumbing fixture wfti the food preparation area that Is not connected to thagrease Interceptor. Employ a gram Interceptor maintenance corrnpeny that Is approved by tine Landlord and the Local Sewer Aurttnorhy- Tenant shag have a Landlord approved corntreotor dean the waste management systems Duos a week or more frequently as established by the Mahtenarm Co*actor or Landlord. The contractor shall keep a mahtenanoe log and support docurrrerrts on site for inspecdlon by the Landlord and Local Arflnorltlse• BEVERAGE LINES PVC piping is NOT permitted in Calling plenums above or below the Tenant's apace. This Includes beverage linea and elseves. Flame and smoke robed polysthylens or equal shall be used. Beverage lure floor, pernshMone in upper level Installations shot be provided with sleeves tiw# extend up through the floor a minimum of 1 and are seaisd to pmh iblt spills from leaking to the Tenant below. KITCHEN DESIGNER NOTICE Kitchen designers and kitchen equipment suppliers should be made aware of the specific requirements of this document as It pertains to specifications and/or installation of services and equipment for Food Court Tenants. 0?J07/04 CONTACT INFO SPECIALTYUFor questions regardino site access,st�ei'ront & C RRA,CE archtWural criteria, engineering design, delivery dates, LAY consbvdlon rules & regulations, the scope of Landlord's Standard Checkl est and Tenant's work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call - - - - 317-636-1600 for assistance. Carmel, Indiana 46432 MEP -3 I III B I GREASE INTERCEPTOR, SIZING GREASE INTERCEPTOR SHALL BE SiZED AS DIRECTED BY PDi STANDARD G101 AS FOLLOWS: 1. DETERMINE CAPACITY OF ALL CONNECTED SINKS IN CUBiC INCHES: ::Zcu •iN. 2• DETERMINE CAPACITY OF ALL CONNECTED IN GALLONS (CU. IN/ 231rFz� GAL DETERMINE ACTUAL DRAINAGE LOAD (0.75 x CAPACITY IN GALLONS.): 1 DETERMINE FLOW RATE REQUIRED TO DRAIN FIXTURE IN ONE MINUTE GAL GPM 3. 4. (ACTUAL DRAINAGE LOAD/1 MiN.k 5. ADD FLOW RATE FOR ALL CONNECTED DISHWASHERS: GPM STT L �TiTeYr.YSTT�■ S. ADD FLOW RATE FOR ALL CONNECTED GRAINS j/ ; \A, GPM (NUMBER OF FLOOR DRAINS x 1 GPM): 7. TOTAL. GPM: GPM 8• SELECT GREASE INTERCEPTOR WITH A F RATE LARGER THAN THE RATE CALCULATED ABOVE. GREASE INT OR SELECTION: MANUFACTURER: FLOW RATE: GPM MODEL NO.: INLET SM' DIA TOTAL CAPACITY: LBS. OUTLET SIZE: DIA WHEN E REQUIRED' A GREASE I EPTORS SHALL BE PROVIDED TO RECEIVE THE DISCHARGE OF ANY PLUMBING FIN'TURE CH MAY RECEIVE GREASE -LADEN WASTE. THESE FIXTURES INCLUDE: ME%/ � vf�llll 0, REE COMPARTMENT SINKS (REGARDLESS OF COOKING METHOD OR TYPE WARE OF FOOD SERVED) MANUFACTURER • .- (2) FLOOR DRAINS (WHERE REQUIRED BY LANDLORD OR LOCAL CODE) -• r MODEL B• 'NOT CONNECT THE FOLLOWING TO GREASE INTERCEPTOR.- NTERCEPTOR:(1) (1)HANDWASH SINKS (2) TOILET ROOM PLUMBING FIXTURES r GREASE (3) GARBAGE DISPOSALS CURS W (4) DISHWASHER (UNLESS REQUIRED BY LOCAL CODE AUTHORITIES) 0?J07/04 CONTACT INFO SPECIALTYUFor questions regardino site access,st�ei'ront & C RRA,CE archtWural criteria, engineering design, delivery dates, LAY consbvdlon rules & regulations, the scope of Landlord's Standard Checkl est and Tenant's work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call - - - - 317-636-1600 for assistance. Carmel, Indiana 46432 MEP -3 I III B I APPUANCE HEAT GAIN CALCULATIONS STT � , - �TiTeYr.YSTT�■ 2 ME%/ � vf�llll 0, ., WARE NOT PERMITT0) MANUFACTURER • .- -• r MODEL ACCESSORIES: r GREASE CURS W UL E. FO - PF KITCHEN MAKE-UP v;kMRER MOTOR POWERHz 0?J07/04 CONTACT INFO SPECIALTYUFor questions regardino site access,st�ei'ront & C RRA,CE archtWural criteria, engineering design, delivery dates, LAY consbvdlon rules & regulations, the scope of Landlord's Standard Checkl est and Tenant's work and store opening requirements, 14311 Clay Terrace Boulevard please contact your Tenant Coordinator or call - - - - 317-636-1600 for assistance. Carmel, Indiana 46432 MEP -3 I III B I