Loading...
HomeMy WebLinkAboutA403.01900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office101-26-2015.23-12-2015.312-15-2015PLAN REVISIONS403-11-2016PCR REVISIONS511-14-2016Plan Revisions............ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 Rick Starkey11-14-2014 LEFT WOODSIDE 2312.300.00.CPM -- 03-11-2016 PLOTTED: December 6, 2016 / Annie Ki / 2312-WOODSIDE-CZ-BASE-EL-HR3T.DWG A3-HR3T 3FB.1Heartland 3T2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:REAR ELEVATION1/8" = 1'-0"- 1210126 \A1;14'-5{\H0.750000x;\S1#8;}"\A1;AT GATHERING OPT. MASONRY WAINSCOTOPT. MASONRY FIRST FLOOR 126 SCALE:LEFT ELEVATION1/8" = 1'-0"- 127127 OPT. MASONRY WAINSCOTOPT. MASONRY FIRST FLOOR 127 127 OPT. 2/8SERVICE DOOR \A1;2'-0"OPT. MASONRY RETURN 127123.5 SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE 127 124 127 ROOF SHINGLES, PER SPEC.6" FASCIA BOARD, PER SPEC. 6" CORNER BOARD, \PPER SPEC. HORIZONTAL SIDING, PER SPEC.OPT. MASONRY WAINSCOT OPT. MASONRY RETURN, \PPER SPEC.\A1;2'-0" 127 123.5 OPT.\A1;7'-6{\H0.750000x;\S1#8;}"\A1;HDR. HGT. @\PBATH 2 SCALE:FRONT ELEVATION1/4" = 1'-0"- \A1;2'-11" \A1;2'-0" \A1;2'-1" \A1;3'-6" \A1;2'-6" \A1;3'-6" 1210 ROOF SHINGLES, PER SPEC.6" FASCIA BOARD, PER SPEC. 6" RAKE BOARD, PER SPEC. FRIEZE, PER SPEC. HORIZONTAL SIDING, PER SPEC. FRIEZE, PER SPEC. BRICK VENEER, PER SPEC. BRICK SOLDIER COURSE, PER SPEC. FYPON #LV12x24, \POR APPROVED EQUAL WITH 4" TRIM SURROUND BOARD & BATTEN SIDING, PER SPEC. 14" SHUTTERS, PER SPEC. STONE SOLDIER COURSE, PER SPEC. ROWLOCK SILL, PER SPEC. 4" TRIM, PER SPEC. BRICK VENEER, PER SPEC. FYPON #LV12x24 OR APPROVED EQUAL WITH \P4" TRIM SURROUND BOARD & BATTEN SIDING, PER SPEC. CL-07AD 2.3SIMILAR 8" TRIM, PER SPEC. TOP OF PLATE TOP OF FLOORTOP OF PLATE TOP OF FOUNDATIONTOP OF FLOOR \A1;8'-1{\H0.750000x;\S1#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.\A1;8'-1{\H0.750000x;\S1#8;}"\A1;AT GARAGE\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. AT GARAGE 1210 1210 1210 1210 SCALE:ROOF PLAN1/8" = 1'-0" "A"1925ROOF AREA:SQ. FT. \A1;1'-0"\PTYP.\A1;14'-0" OPT. POT VENTS 10:12 10:1210:12 7:12 7:12PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION MIN. 108 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF 6:12 6:12 3.5:12 10:1210:12 10:12 7:127:12 7:12 4:124:12 4:124:12 \A1;4'-0" \A1;2'-0" MIN. 124 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF \A1;7'-0" \A1;6'-0" \A1;4'-0" 5:12 "B"449ROOF AREA:SQ. FT. \A1;2'-0" 7:12 7:1210:12 Heartland 3T ATTIC VENT SCHEDULE ROOF AREA "A"SQ FTG 1925 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 POT VENTS ONLY 2.57 3.21 2.97 46.06 7 0 AT EAVE 3.85 3.21 3.47 53.94 0 50.00 TOTAL (MIN)6.42 6.42 6.44 100.00 RIDGE VENT 2.57 3.21 3.00 46.35 0 0 24.00 AT EAVE 3.85 3.21 3.47 53.65 0 50.00 TOTAL (MIN)6.42 6.42 6.47 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE{\C0;VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE\P** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS\P* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION} ROOF AREA "B"SQ FTG 449 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 POT VENTS ONLY 0.60 0.75 0.85 48.41 2 0 AT EAVE 0.90 0.75 0.90 51.59 0 13.00 TOTAL (MIN)1.50 1.50 1.75 100.00 RIDGE VENT 0.60 0.75 0.81 49.15 0 2 2.00 AT EAVE 0.90 0.75 0.83 50.85 0 12.00 TOTAL (MIN)1.50 1.50 1.64 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE SCALE: SIDE AND REAR WINDOW TRIM PER COMMUNITY SPECS1/4" = 1'-0"- VINYL DIMENSIONAL TRIM 03/13/18 Adam Schriner