HomeMy WebLinkAboutE201.01900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office101-26-2015.23-12-2015.312-15-2015PLAN REVISIONS403-11-2016PCR REVISIONS511-14-2016Plan Revisions............
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2016
Rick Starkey11-14-2014
LEFT
WOODSIDE
2312.300.00.CPM
--
03-11-2016
PLOTTED: December 5, 2016 / Annie Ki / 2312-WOODSIDE-CZ-BASE-UTIL.DWG
U1
4-2.20Second Floor Utility Plan - Options4" Exterior WallsFAN-EXHAUST
SSSV
V
GFI
GFI
OWNER'S BATHOWNER'S BATH
SFAN-EXHAUST-LIGHTS
FAN-EXHAUST
SSSV
V
GFI
GFI
OWNER'S BATHOWNER'S BATH
SFAN-EXHAUST-LIGHTS SFAN-EXHAUST-LIGHTS
SGFI
GFI
FAN-EXHAUST
S
OWNER'S BATHOWNER'S BATH
S
V
V
SCALE:BATH 2 w/ SHOWER OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:BATH 2 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
SCALE:OWNER'S BATH 3 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:OWNER'S BATH 4 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:OWNER'S BATH 5 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
FAN-EXHAUST-LIGHT
GFI
GFI
FAN-EXHAUST
GFI
S
GFI
S VS 3S3S
3S3S
BATH 2BATH 2
BATH 2BATH 2
SCALE:BATH 2 OPTION w/SHOWER OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
GFI
GFI3S3S
FAN-EXHAUST-LIGHT
3S3S
BATH 2BATH 2
FAN-EXHAUST
SSSV
V
GFI
GFI
OWNER'S BATHOWNER'S BATH
SFAN-EXHAUST-LIGHTS
SCALE:OWNER'S BATH 2 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
5
UTILITY LEGEND
SYMBOL SYMBOL TYPE ADDITIONAL NOITES
ADDRESS SIGN ADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF
CHIMES - DOORBELLDETECTOR - HEATCEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE)
DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONUL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - CARBON MONOXIDE UL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - SMOKE UL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHTFAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)
FAN - EXHAUSTEXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHTEXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14
LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRICVERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONE CAT 5EOUTLET - TVRG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRICVERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTATTHERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METER
HS/C
C
S
PC
14RV
PCE220VDW
GFIGFI
PHTVWP/GFI
SDISPS3SS4
THBOPT.\PWATER LINE
GAS VALVEGR.A.G.W
SCALE:BATH 3 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
BEDROOM 2BEDROOM 2
SS
SPC
WICWIC
S GFI
FAN-EXHAUST SS
WICWIC
03/13/18
Adam Schriner