Loading...
HomeMy WebLinkAboutE201.01900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office101-26-2015.23-12-2015.312-15-2015PLAN REVISIONS403-11-2016PCR REVISIONS511-14-2016Plan Revisions............ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 Rick Starkey11-14-2014 LEFT WOODSIDE 2312.300.00.CPM -- 03-11-2016 PLOTTED: December 5, 2016 / Annie Ki / 2312-WOODSIDE-CZ-BASE-UTIL.DWG U1 4-2.20Second Floor Utility Plan - Options4" Exterior WallsFAN-EXHAUST SSSV V GFI GFI OWNER'S BATHOWNER'S BATH SFAN-EXHAUST-LIGHTS FAN-EXHAUST SSSV V GFI GFI OWNER'S BATHOWNER'S BATH SFAN-EXHAUST-LIGHTS SFAN-EXHAUST-LIGHTS SGFI GFI FAN-EXHAUST S OWNER'S BATHOWNER'S BATH S V V SCALE:BATH 2 w/ SHOWER OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:BATH 2 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:OWNER'S BATH 3 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:OWNER'S BATH 4 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN SCALE:OWNER'S BATH 5 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN FAN-EXHAUST-LIGHT GFI GFI FAN-EXHAUST GFI S GFI S VS 3S3S 3S3S BATH 2BATH 2 BATH 2BATH 2 SCALE:BATH 2 OPTION w/SHOWER OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN GFI GFI3S3S FAN-EXHAUST-LIGHT 3S3S BATH 2BATH 2 FAN-EXHAUST SSSV V GFI GFI OWNER'S BATHOWNER'S BATH SFAN-EXHAUST-LIGHTS SCALE:OWNER'S BATH 2 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN 5 UTILITY LEGEND SYMBOL SYMBOL TYPE ADDITIONAL NOITES ADDRESS SIGN ADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF CHIMES - DOORBELLDETECTOR - HEATCEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE) DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONUL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DETECTOR - CARBON MONOXIDE UL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DETECTOR - SMOKE UL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE) DISCONNECT - SWITCHEDFAN - CEILING W/ LIGHTFAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL) FAN - EXHAUSTEXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHTEXHAUST TO EXTERIORLIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-UNDER CAB-14 LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRICVERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONE CAT 5EOUTLET - TVRG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRICVERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTATTHERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METER HS/C C S PC 14RV PCE220VDW GFIGFI PHTVWP/GFI SDISPS3SS4 THBOPT.\PWATER LINE GAS VALVEGR.A.G.W SCALE:BATH 3 OPTION1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN BEDROOM 2BEDROOM 2 SS SPC WICWIC S GFI FAN-EXHAUST SS WICWIC 03/13/18 Adam Schriner