HomeMy WebLinkAboutA0.01SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE
FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATION
2A2 B.1
1A2 B.1
1A2 B.1
2A2 B.1
3A2 B.2
4A2 B.2 4A2 B.2
PERIMETER DRAIN, PER SPEC
UP 7 RISERS
HANDRAIL, PER CODE
1234567 POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS
12345678
\pxql;2/8
FD
4140 SL & EGRESS WELL #1, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS
4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS
OPT\PROUGH IN BATH
36x60 SHOWER
GFI
S3S
GFIGAS VALVE
GFI
S
3S
220V
S
POST & BEAM PER STRUCTURAL PLANS
ADD RISER W/ OPT. 9'-0" POUR
LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL)\pxql;PAD FOOTING w/ OUTDOOR FIREPLACE OPTION GFI
GFI
\A1;22'-8{\H0.750000x;\S1#2;}"\A1;10'-7{\H0.750000x;\S1#2;}"
\A1;10'-3{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"\A1;15'-11{\H0.750000x;\S1#2;}"
\A1;10'-8"
\A1;18'-8"
\A1;18'-8"\A1;19'-5"
\A1;12'-1"
\A1;6'-5{\H0.750000x;\S1#2;}"
\A1;4'-5{\H0.750000x;\S1#4;}"
\A1;7'-0"\A1;48'-0" - OVERALL
\A1;31'-6"
\A1;16'-6"
\A1;2'-11{\H0.750000x;\S3#4;}"
\A1;5'-0"
\A1;2'-7{\H0.750000x;\S1#4;}"
\A1;20'-6{\H0.750000x;\S1#2;}"\A1;1'-5{\H0.750000x;\S1#2;}"\A1;2'-7{\H0.750000x;\S1#2;}"\A1;14'-0"
\A1;17'-6"
\A1;12'-0"
\A1;2'-0"
\A1;42'-3{\H0.750000x;\S1#2;}"
SLAB/UNEXCAVATED (SEE STRUCTURAL PLANS)
LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)
\A1;33'-4"
\A1;29'-4"
\A1;48'-0" - OVERALL
\A1;19'-9{\H0.750000x;\S1#2;}"
\A1;9'-6{\H0.750000x;\S1#2;}"
\A1;64'-3{\H0.750000x;\S1#2;}" - OVERALL \A1;30'-11{\H0.750000x;\S1#2;}"
\A1;55'-0" - OVERALL
\A1;11'-11{\H0.750000x;\S1#2;}"
\A1;1'-9"\A1;2'-6{\H0.750000x;\S1#2;}"
\A1;11'-8"
\A1;8'-3"\A1;2'-2"\A1;16'-3"
LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)
\A1;10'-8"
\A1;8'-0"
\A1;1'-9{\H0.750000x;\S1#2;}"
\A1;4'-5"
\A1;1'-9{\H0.750000x;\S1#2;}"
\A1;2'-8"\A1;1'-9{\H0.750000x;\S1#2;}"\A1;10{\H0.750000x;\S1#2;}"\A1;5'-4"\A1;1'-9{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"
\A1;8'-10{\H0.750000x;\S1#2;}"
\A1;1'-9{\H0.750000x;\S1#2;}"HVACBASEMENT UNFINISHEDSLAB (SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS)PORCHUNEXCAVATED (SEE STRUCTURAL PLANS)
\A1;6'-4"
\A1;11'-2"
3A2 B.2
\A1;47'-0" TO CORNER
\A1;10'-6"
\A1;5'-2"
\A1;12'-6{\H0.750000x;\S1#2;}"
A0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2017 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/12/2016
PROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Allison II
2377.300Home for * Market Home *, 5581-01600#24416 Voyageur Way, Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
03/12/18
Adam Schriner