Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04060221 Building Plans
DEMOLITION PLAN LEGEND EXISTING WALL TO REMAIN. EXISTING DOOR & FRAME TO REMAIN EXISTING WALL TO BE DEMOLISHED. / EXISTING DOOR AND FRAME TO BE DEMOLISHED DEMOLITION PLAN KEYNOTES NONE T € w DEMOLITION PLAN__ GENERAL NOTES D1. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. LIGHT—WEIGHT, SOLID LINES INDICATED EXISTING CONSTRUCTION TO REMAIN. SALVAGE REUSABLE ITEMS. NOTE THAT MANY ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. D2. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. D3. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. D4. DO NOT REMOVE EXISTING CEILING GRID AND TILE. REPAIR OR REPLACE EXISTING GRID AND TILES AS REQUIRED AT AREAS OF DEMOLITION AND FOR NEW CONSTRUCTION. D5. BE CAREFUL ABOUT DEMOLITION; EXISTING CEILING, H.V.A.C., FIRE PROTECTION, AND ELECTRICAL ITEMS CAN BE RE—USED IF IN GOOD CONDITION. D6. REMOVE AND SALVAGE ELECTRICAL LIGHTING FIXTURES AS REQUIRED FOR NEW CONSTRUCTION. REUSE EXISTING ELECTRICAL LIGHTING FIXTURES IF POSSIBLE. D7. REMOVE ALL ABANDONED DATA CABLE ABOVE CEILING AND IN WALLS AS APPLICABLE. CONSULT WITH LANDLORD ON EXTENT OF WORK. AREAS N.I.C. = " = AREA OF WORK KEY PLAN SECOND FLOOR NO SCALE PLAN - DEMOLITION SECOND FLOOR N 0' 4' 8' 16' 24' MERIDIAN TOWER 201 W. 103RD ST. SCALE: 1/8" = 1'-0" CARMEL, IN isions: Issue: STATE SUBMITTAL ISSUE a r I I IN f I AREA LOCATION MAP -INDIANAPOLIS, IN. -13 N DRAWING F-- - �a� ' a SCHEDULE co i 1 fj D111 PLAN — DEMOLITION A111 PLAN — ARCHITECTURAL FLOOR A121 PLAN — ARCHITECTURAL FINISHES A131 PLAN — REFLECTED CEILING, FIRE—PROTECTION, cc L Brft "St HVAC, ELECTRICAL LIGHTING A211 SCHEDULE — DOOR, ARCHITECTURAL DETAILS E111 PLAN — ELECTRICAL POWER +y am I `;.rd3° 3L AREAS N.I.C. = " = AREA OF WORK KEY PLAN SECOND FLOOR NO SCALE PLAN - DEMOLITION SECOND FLOOR N 0' 4' 8' 16' 24' MERIDIAN TOWER 201 W. 103RD ST. SCALE: 1/8" = 1'-0" CARMEL, IN isions: Issue: STATE SUBMITTAL ISSUE a r I I IN f I AREA LOCATION MAP -INDIANAPOLIS, IN. -13 N F-- - �a� ' a cLB E 1 1 t 6 St co i 1 fj 1ftp Lj i Z� Lir w- ati o Hom t� (- - E 145 cc L Brft "St IWMrd -North Ridge -.Y '3i 1 25 IOROD.R!jjf�atrio r O 's - P � kw s p} +y am I `;.rd3° 3L )wth-sb Hart) i Ito n E 961 h st _ =� E 95t Sii Calle a Cres g rj Pipe Dr ,-- - �t - Spring`Hall'aw'. I E9rd S[ tri r ! W 92nd -S[ �4 W '3 E 91st St ue t.com. Inc.*4 NA AREAS N.I.C. = " = AREA OF WORK KEY PLAN SECOND FLOOR NO SCALE PLAN - DEMOLITION SECOND FLOOR N 0' 4' 8' 16' 24' MERIDIAN TOWER 201 W. 103RD ST. SCALE: 1/8" = 1'-0" CARMEL, IN isions: Issue: STATE SUBMITTAL ISSUE a r I I IN f I BASE AS BASE AS BASE AS SCHEDULED SCHEDULED N SCHEDULED 35/8" METAL STUDS AT 16" O.C. 35/8" METAL STUDS AT 16" O.C. 35/8" METAL STUDS AT 16" O.C. ONE LAYER OF 5/8" TYPE "X" GYPSUM ONE LAYER OF 5/8" TYPE "X" GYPSUM ONE LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. BOARD EACH SIDE. BOARD EACH SIDE. EXTEND WALL TO DECK. EXTEND WALL TO UNDERSIDE OF EXTEND WALL TO UNDERSIDE OF CEILING. CEILING. FIBERGLASS BATT SOUND INSULATION INSIDE WALL. FIBERGLASS BATT SOUND INSULATION MATCH EXISTING STUD THICKNESS AT INSIDE WALL AND 2'-0" EACH SIDE DOOR INFILLS. MATCH EXISTING STUD THICKNESS AT OF WALL DOOR INFILLS. MATCH EXISTING STUD THICKNESS AT DOOR INFILLS. WALL TYPE "13" WALL TYPE "W2" WALL TYPE 99W,99 NOTE: ALL NEW WALLS ARE WALL TYPE: W1 UNLESS NOTED OTHERWISE WALL TYPE S: SCALE: 3/8" = 1'-0" A SECOND FLOOR 11 PLAN -ARCHITECTURAL ARCHITECTURAL GENERAL NOTES Al. PROVIDE FIRE—TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALLSTOPS, CABINETRY, ETC. A2. CONTRACTOR IS TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. A3. FIELD CHECK ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF JOB CONDITIONS PREVENT OBTAINING DIMENSIONS OR RESULTS AS SHOWN OR SPECIFIED. A4. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY TO THE GENERAL CONTRACTOR WHO, IN TURN, MUST REPORT THE DISCREPANCY TO SCHOTT DESIGN, INC. A5. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. A6. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR FOR CHECKING, ORDERING, FABRICATION, OR DELIVERY OF MATERIALS AND EQUIPMENT. A7. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL 3UILDING CODES AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. A8. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC. AND FINAL APPROVAL BY THE OWNER. A9. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE—BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. WALL LEGEND NEW WALL EXISTING WALL (SEE WALL TYPES TO REMAIN. m7W? ON THIS SHEET) DOOR LEGEND ARCHITECTURAL DOOR AND FRAME 77OUTSIDE SCOPE OF WORK. PLAN KEYNOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. A02 ALIGN NEW WALL WITH CENTERLINE OF EXTERIOR WINDOW MULLION. REFER TO REFERENCED DETAIL 1/A211. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION Aa3 HAS OCCURED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. ALL CONDITIONS MAY NOT BE SHOWN ON DRAWING. A04 PROVIDE ROD AND SHELF. SEE DETAIL 2/A211 REUSE EXSITING COOLING UNIT ABOVE CEILING A05 FROM DEMOLITION ON THIS FLOOR IN THIS ROOM. EXISTING CORRIDOR DEMISING WALL f0 REMAIN. Aas CONFIRM IF EXISTING WALL GOES TO DECK. IF NOT, CONTRACTOR TO BUILD NEW WALL ON TOP OF EXISTING TO EXTEND TO DECK. A07 PROVIDE 4X8 PLYWOOD PHONE BOARD IN THE DATA ROOM. PAINT PHONE BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. A08 REUSE WHITE BOARD WALLS FROM DEMOLITION IF POSSIBLE. (BUILD BULKHEAD 7" ABOVE WALLS TO MEET 10'-0" CEILING HEIGHT. A SECOND FLOOR 11 PLAN -ARCHITECTURAL ARCHITECTURAL GENERAL NOTES Al. PROVIDE FIRE—TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALLSTOPS, CABINETRY, ETC. A2. CONTRACTOR IS TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. A3. FIELD CHECK ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF JOB CONDITIONS PREVENT OBTAINING DIMENSIONS OR RESULTS AS SHOWN OR SPECIFIED. A4. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY TO THE GENERAL CONTRACTOR WHO, IN TURN, MUST REPORT THE DISCREPANCY TO SCHOTT DESIGN, INC. A5. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. A6. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR FOR CHECKING, ORDERING, FABRICATION, OR DELIVERY OF MATERIALS AND EQUIPMENT. A7. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL 3UILDING CODES AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. A8. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC. AND FINAL APPROVAL BY THE OWNER. A9. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE—BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. WALL LEGEND NEW WALL EXISTING WALL (SEE WALL TYPES TO REMAIN. m7W? ON THIS SHEET) DOOR LEGEND DOOR AND FRAME ® WITHIN SCOPE OF WORK (SEE DOOR SCHEDULE). DOOR AND FRAME 77OUTSIDE SCOPE OF WORK. IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. AREAS N.I.C. = Revisions: \\\w111111411111, '// INN No. 910039 STATE OF VIM U - Issue: STATE SUBMITTAL ISSUE N I I r Z' 0 PLAN — ;HITECTURAL FINISHES 0' 4' 8' 16' 24' I%d% I I SCALE: 1/8" = V-0" ARCH. FINISHES GENERAL NOTES FG1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. FG2. ALL NEW PLATES AND SWITCHES ARE TO BE BUILDING STD. COLOR TO MATCH EXISTING. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS. FG3. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. FG4. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR. (WHERE VCT MEETS CARPET) FGS. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. FG6. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURED. ARCH. ARCH. FINISHES ARCH. FINISHES LEGEND FLOOR COVERINGS �r CARPET CPT) MFG.: SHAW CONTRACT TYPE: LATEX PATTERN: EVOLUTION COLOR: SW 0036 BUCKRAM BINDING COLOR: BARE NECESSITIES FINISH: EGGSHELL APPLICATION: GLUE -DIRECT MFG.: SHERMAN WILLIAMS SDI BUILDING STANDARD PROGRAM TYPE: LATEX VINYL COMPOSITE TILE vCT1 MFG.: ARMSTRONG FINISH: EGGSHELL SIZE: 12"x12" (PATTERN 24"x24" WALLCOVERING CHECKERBOARD) MFG.: DL COUCH, VERSA PATTERN: IMPERIAL TEXTURE TYPE: BUILDING STANDARD, TYPE I COLOR: #51809 vCT2 MFG.: ARMSTRONG LAMINATE SIZE: 12"x12" (PATTERN 24"x24" CHECKERBOARD) WALL PATTERN: IMPERIAL TEXTURE vB1 COLOR: #51925 VCT3 MFG.: ARMSTRONG SIZE: 12"x12" (PATTERN 24"x24" 0 CHECKERBOARD) SDT STATIC DISSIPATIVE TILE, COMPLETE FLOORING SYSTEM. (USE SDT ADHESIVE, COPPER GROUND STRIPS AND S-392 SDT POLISH) COLOR: #51954 SANDSTONE BEIGE vCT4 MFG.: ARMSTRONG SIZE: 12"x12" (PATTERN 24"x.24" CHECKERBOARD) SDT STATIC DISSIPATIVE TILE, COMPLETE FLOORING SYSTEM. (USE SDT ADHESIVE, COPPER GROUND STRIPS AND S-392 SDT POLISH) COLOR: #51956 FOSSIL GRAY PLAN — ;HITECTURAL FINISHES 0' 4' 8' 16' 24' I%d% I I SCALE: 1/8" = V-0" ARCH. FINISHES GENERAL NOTES FG1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. FG2. ALL NEW PLATES AND SWITCHES ARE TO BE BUILDING STD. COLOR TO MATCH EXISTING. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS. FG3. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. FG4. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR. (WHERE VCT MEETS CARPET) FGS. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. FG6. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURED. ARCH. FINISHES ARCH. FINISHES KEY LEGEND PAINT �r PT1 MFG.: SHERMAN WILLIAMS NOT USED TYPE: LATEX F02 COLOR: SW 0036 BUCKRAM BINDING ` FINISH: EGGSHELL PT2 MFG.: SHERMAN WILLIAMS w TYPE: LATEX COLOR: SW0040 ROYCROFT ADOBE g4 FINISH: EGGSHELL VINYL WALLCOVERING WC1 MFG.: DL COUCH, VERSA TYPE: BUILDING STANDARD, TYPE I COLOR: A29-663 PLASTIC LAMINATE PL1 MFG: WILSONART COLOR: CLAY ROLETfA #4739-60 WALL BASE vB1 MFG.: JOHNSONITE TYPE: VINYL COVE, y8" GUAGE SIZE: 4" 0 COLOR: #49 BEIGE PLAN — ;HITECTURAL FINISHES 0' 4' 8' 16' 24' I%d% I I SCALE: 1/8" = V-0" ARCH. FINISHES GENERAL NOTES FG1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. FG2. ALL NEW PLATES AND SWITCHES ARE TO BE BUILDING STD. COLOR TO MATCH EXISTING. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS. FG3. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. FG4. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR. (WHERE VCT MEETS CARPET) FGS. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. FG6. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURED. KEY PLAN CD.o SCALE SECOND FLOOR N MERIDIAN TOWER 201 W. 103RD ST. CARMEL, IN • ARCH. FINISHES Uc4on KEY NOTES �r F01 NOT USED Z00 co u):5 fh M F02 NEW COMMON CORRIDOR. LANDLORD WILL ` PROVIDE NEW BUILDING STANDARD FINISHES. KEY PLAN CD.o SCALE SECOND FLOOR N MERIDIAN TOWER 201 W. 103RD ST. CARMEL, IN • wAoo Uc4on Q��n �r HQnn R Z00 co u):5 fh M wQ ` ZZ�n CO w Q J = a. g4 CO¢_jX N p W Q U. PO k Revisions: co W T� V1 F�1 z rH PL1 a F w H 0-4x x z P-4 \\\\`�\\aunl ii/�,���� �' %ST ..<<�,L�. NO. 910039 STATE OF Issue: STATE SUBMITTAL ISSUE Date: 06.03.2004 Sheet: A121 a I a a 0 IN a 0 wQ E-+ w 1-1 g4 QI PO k Z 0 w W 0 ASU W Revisions: co W T� V1 F�1 z rH PL1 a F w H 0-4x x z P-4 \\\\`�\\aunl ii/�,���� �' %ST ..<<�,L�. NO. 910039 STATE OF Issue: STATE SUBMITTAL ISSUE Date: 06.03.2004 Sheet: A121 a I a a 0 IN ELECTRIC LIGHTING KEYNOTES NONE E CTRIC LIGHTING _ LEGEND EXIST. DIFFUSER, ® LAY -IN, SLOT IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW EQUIPMENT. .•:, V'�>za;�s rnF, NEW OR RELOCATED REUSE EXISTING FLUORESCENT I I I --- ! --- I— LIGHT FIXTURE, 2'x4', i zz�� PARABOLIC PENDANT LIGHTS II----! —---------- FLUORESCENT T8 FROM 1ST FLOOR �-- LAMPS DEMOLITION. I I I I I ! ELECTRICIAN TO rn CONFIRM EXACT NIGHT LIGHT LOCATION QUANTITY NEEDED. NEW LIGHT FIXTURE, INCANDESCENT, CAN i I I I NEW OR RELOCATED I I I I LIGHT FIXTURE, ME, I EMERGENCY a ® NEW OR RELOCATED LIGHT FIXTURE, EXIT I I I $N NEW LIGHT SWITCH I I $ND NEW DIMMER SWITCH I I _ I " ME ----- NEW LIGHT CIRCUIT ! I Fm ELECTRIC LIGHTING GENERAL NOTES ELI. ELECTRIC LIGHTING WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, FUNCTIONAL SYSTEM. EL2. COMPLY WITH THE INDIANA ELECTRICAL CODE AND ALL OTHER APPLICABLE CODES. EL3. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. EL4. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS. ELS. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. EL6. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE IF REQUIRED. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. EL7. PROVIDE EXIT SIGNS, HORNS, STROBES, SPEAKERS, OR OTHER LIFE—SAFETY DEVICES AS NECESSARY TO MEET ALL APPLICABLE CODES. ELB. IF REQUIRED AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. H.V.A.C. KEYNOTES M01 RELOCATE EXISTING COOLING UNIT TO ABOVE CEILING FROM DEMOLITION. ENSURE IT IS IN PROPER WORKING CONDITION. H.V.A..C. GENERAL NOTES M1. H.V.A.C. WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A FUNCTIONAL, COMFORTABLE ENVIRONMENT AND A COMPETE, WORKING SYSTEM. M2. COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. M3. VERIFY HEAT LOADS OF ANY SPECIAI_ EQUIPMENT IN THE TENANT SPACE AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. M4. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE. M5. RELOCATE AIR—SUPPLY DIFFUSERS AND RETURN—AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. M6. POSITION AND COORDINATE THERMOSTATS WITH TENANT'S FURNITURE AND WITH BUILDING OWNER. U -----t----t-- -r---- -----------fi----I-- I--- in FMI 1 H I g H H Ntj 4� I $a� ?.£ ----=-----4----- -------- ---- I m���k^ I I ° •�.' I _0111 TI I I I I I M ND I I I I I I I I I I I I I I HIT- - --------- --- ---- - -- ----- -- - ---- ---- -� H -- � ' H.V.A.C. LEGEND _ NEW OR RELOCATED DIFFUSER, LAY -IN, SLOT NEW DIFFUSER, LAY -IN, 2'x2' EXIST. DIFFUSER, ® LAY -IN, SLOT IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW EQUIPMENT. .•:, V'�>za;�s H.V.A.C. KEYNOTES M01 RELOCATE EXISTING COOLING UNIT TO ABOVE CEILING FROM DEMOLITION. ENSURE IT IS IN PROPER WORKING CONDITION. H.V.A..C. GENERAL NOTES M1. H.V.A.C. WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A FUNCTIONAL, COMFORTABLE ENVIRONMENT AND A COMPETE, WORKING SYSTEM. M2. COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. M3. VERIFY HEAT LOADS OF ANY SPECIAI_ EQUIPMENT IN THE TENANT SPACE AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. M4. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE. M5. RELOCATE AIR—SUPPLY DIFFUSERS AND RETURN—AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. M6. POSITION AND COORDINATE THERMOSTATS WITH TENANT'S FURNITURE AND WITH BUILDING OWNER. U -----t----t-- -r---- -----------fi----I-- I--- in FMI 1 H I g H H Ntj 4� I $a� ?.£ ----=-----4----- -------- ---- I m���k^ I I ° •�.' I _0111 TI I I I I I M ND I I I I I I I I I I I I I I HIT- - --------- --- ---- - -- ----- -- - ---- ---- -� H -- � ' �: z.'2�:`�,: _ I �. a ..._ . 1.• — .•:, V'�>za;�s -- ax: yti.'� I I I I --- ! --- I— co 00 Cn Q MM i zz�� II----! —---------- ---- ----J----- --------------�---- --- I ---------- I I �-- =Qa„ I I I I I ! E-4 rn NpwQ POw I i I I I I I I I I I � ME, I w a ---- I I I I I — I I I I ! I I I I _ I " ME ----- I I I ! I Fm I ! t I I HT PLAN -REFLECT ;EILING 0' 4' 8' 16' 24' SCALE: 1/8" = 1'-0" REFLECTED CEILING GENERAL NOTES RC1. REUSE EXISTING CEILING GRID AND TILE. EXISTING GRID IS 2'X4' AT t10'-0" A.F.F. TILES ARE 2'X4' FISSURED ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED CEILING TILES WITH NEW TO MATCH EXISTING. REFLECTED CEILING LEGEND Uc�or -�-----i-- EXIST. CEILING I I GRID, SUSPENDED, Q��n ------r- 2'x4' I I REFLECTED CEILING PLAN KEYNOTES 8 NONE FIRE PROTECTION GENERAL NOTES FP1, FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. FP2. COMPLY WITH THE INDIANA BUILDING CODE AND ALL OTHER APPLICABLE CODES FOR FIRE PROTCTION. FP3. FILE APPROPRIATE DRAWINGS WITH STATE AND CITY OFFICIALS. FP4. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. FPS. PROVIDE MISSING COVER PLATES FOR SPRINKLER HEADS WITHOUT PLATES. FIELD VERIFY EXISTING CONDITIONS. KEY PLAN NO SCALE /, SECOND FLOOR N MERIDIAN TOYER 201 W. 103RD ST. CARMEL, IN • woo Uc�or Q��n ^ r Qz co 00 Cn Q MM zz�� F -mm Ln Q J =Qa„ • 00Q �X E-4 rn NpwQ POw Revisions: �\x1\11111111A�i�u ii/z�i'/ No. 910039 STATE OF NQ Dim TviI -n,- Issue: STATE SUBMITTAL ISSUE Date: 06.03.2004 Sheet: A 13 1 i' f a f' 0 N I I 0 cq wo E-4 rn POw Z O w � E" • w a F+1 w Revisions: �\x1\11111111A�i�u ii/z�i'/ No. 910039 STATE OF NQ Dim TviI -n,- Issue: STATE SUBMITTAL ISSUE Date: 06.03.2004 Sheet: A 13 1 i' f a f' 0 N I I 0 i a B24 WALL CABINETS (SEE MILLWORK GENERAL NOTES) NEW 2'-0"(25") PLASTIC LAMINATE (PL1) COVERED COUNTER WITH 4" BACKSPLASH. BASE CABINETS (SEE MILLWORK GENERAL NOTES) B18 B30 COPY WORK ROOM 203 CABINETRY ELEVATION - CABINET SCALE: 3/8" = 1'-0" CONFERENCE 204 WALL ELEVATION - WALL SCALE: 1/4" = 1'-0" 15'-1» DATA ROOM 213 WALL ELEVATION -WALL 21 VSCALE: 1/4" = 1'-0" TO EXIST. OR _ NEW 4" VENT THROUGH I ROOF , , � 1 1y2'v.-w I I 4. SINK ' DOOR SCHEDULE 2"W. DIMENSIONS F.� I DOORS 4 , (SEE MILLWORK I REMARKS TYPE MATERIAL , i TYPE 2"W. FINISH I F.F. GENERAL NOTES)-��- 2"W. D2 EXIST TO 4"W BUILDING BREAK 121 DRAIN 1 DIAGRAM - RISER :11.01 SCALE: 1/4"=l'—O" REBUILD HEAD AS REQUIRED DUE TO HIGHER CEILING HEIGHT THIS FLOOR REUSE 30" GLASS AND FRAMES FROM DEMOLITION REBUILD BASE IF NECESSARY. CURRENT LOCATION IS BUILT ON A RADIUS CURVE. REBUILD HEAD AS REQUIRED DUE TO HIGHER CEILING HEIGHT THIS FLOOR REUSE 30" LASS AND =RAMES FROM )EMOLITION REBUILD BASE IF NECESSARY. CURRENT LOCATION IS BUILT ON A RADIUS CURVE. MILL AND CASEWORK GENERAL NOTES MW1. MILLWORK AND CASEWORK CONTRACTOR(S) ARE TO FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. MW2. ALL DIMENSIONS ON PLANS ARE TO BE FIELD VERIFIED BY MILLWORK AND CASEWORK CONTRACTOR(S). MW3. PROVIDE STANDARD BASE AND UPPER CABINETS, BUILDING STOCK CABINETRY, OAK, FROST STAIN, UNLESS OTHERWISE NOTED, STANDARD OVERLAY, FINGER PULLS IN DRAWERS. TIMBERLAKE, TAHOE, OAK, SQUARE FROST OR EQUAL. MW4. PROVIDE 25" DEEP, PLASTIC LAMINATE TOP W/ BACKSPLASH. WC3030 WC3015 WC3615 WALL CABINETS DOOR SCHEDULE N0. DIMENSIONS DOORS (SEE MILLWORK HDWR. SET REMARKS TYPE MATERIAL FINISH TYPE MATERIAL FINISH 01 GENERAL NOTES)-��- D2 SOLID CORE WOOD VENEER STAINED F2 ;HOOD FRAME 8 A211 STAINED #2 22"x25" S.S. `14 02 I /I` 30" Ir==� PLAN - ELECTRIC POWER ELECTRICAL POWER GENERAL NOTES EP1. ELECTRIC POWER WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. EP2. COMPLY WITH THE INDIANA ELECTRICAL CODE AND ALL OTHER APPLICABLE CODES. EP3. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. EP4. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. EP5. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA AND LAN CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. EP6. PROVIDE ALMOND COLORED FACEPLATES FOR ELECTRICAL OUTLETS TO MATCH EXISTING. EP7. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. SUCH REFERENCED ITEMS ARE USUALLY SHOWN WITH DASHED LINES ON THIS DRAWING. PROVIDE ELECTRIC POWER TO, BUT NOT THROUGH OFFICE PARTITIONS SYSTEMS. AREAS N.I.C. = " = AREA OF WORK KEY PLAN NO SCALE SECOND FLOOR N Revisions: GESTNo i 910039 STATE OF 15 S\\\ J -DAM qW1 ' Issue: STATE SUBMITTAL ISSUE a I I I r 0 I NEW POWER OUTLET, DUPLEX EXIST. POWER OUTLET, DUPLEX �Q FLOOR MOUNTED, FLUSH, ELEC & DATA EXIST. POWER OUTLET, QUADRUPLEX NEW BOX, (J)UNCTION FOR POWER SUPPLY Q EXIST. BOX,B) LANK COVER PLATE TWISTLOCK IN CEILING 120 V. 30A, DEDICATED © EXIST. BOX, BLANK COVER PLATE D DENOTES DEDICATED D DENOTES DEDICATED CIRCUIT CIRCUIT DENOTES GROUND DENOTES GROUND GFCI FAULT CICUIT GFCI FAULT CICUIT INTERRUPT OUTLET INTERRUPT OUTLET DENOTES HEIGHT OF DENOTES HEIGHT OF +42" ELECTRICAL OR DATA +42" ELECTRICAL OR DATA DEVICE DEVICE NEW DATA/ COMMUN- ICATION OUTLET b EXISTING DATA/ (PROVIDE BOX AND A COMMUNICATION DEVICE. PULL STRING ONLY) ® NEW BOX, (J)UNCTION FOR DATA SUPPLY IF IN GOOD CONDITION, EXISTING ELECTRICAL DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW EQUIPMENT. AREAS N.I.C. = " = AREA OF WORK KEY PLAN NO SCALE SECOND FLOOR N Revisions: GESTNo i 910039 STATE OF 15 S\\\ J -DAM qW1 ' Issue: STATE SUBMITTAL ISSUE a I I I r 0 I