04-A005
EXISTINGSEVICE CORRIDOR CVIT 00 -LIFE SAFETY PLAN 1/411 = 1'-011 RELEASED FOR CONSTRUCTION Sub9ecl tc comipIlianice with all regulations of State and (local Cmdles City of !Carmol) DATE: 03/14/18 Nick Mishler CODE REFERENCES BUILDING CODE ANALYSIS ASSEMBLY AREA BUILDING CODE 2012 INTERNATIONAL BUILDING CODE / 2014 INDIANA AMENDMENTS PROJECT TYPE + SIZE LENGTH OF TRAV EL 250 -FT MAX. (A-2 OCCUPANCY W/ SPRINKLER) MUCHANICAL CODE 2012 INTERNATIONAL MECHANICAL CODE / 2014 INDIANA AMENDMENTS 106'x 49' INTERIOR FINISH (1 -STORY) AREAS WITH ONE EXIT LIMITED TO 49 OCCUPANTS AND PLUMBING CODE 2006 INTERNATIONAL PLUMBING CODE / 2012 INDIANA AMENDMENTS 83 75 -FT TRAVEL DISTANCE (SPRINKLERED) ELECTRIC CODE 2008 NATIONAL ELECTRIC CODE / 2009 INDIANA AMENDMENTS GROSS AREA: ENERGY CONSERVATION CODE 2012 ASH RAE 90.4 / 2010 INDIANA AMENDMENTS MAIN BUILDING4,701 SF (CONDITIONED SPACE) EXITS FIRE CODE 2006 INTERNATIONAL FIRE CODE / 2014 INDIANA AMENDMENTS PATIO 491 REQUIRED (MIN.): 2 ACCESSIBILITY GUIDELINES 2009 ICC/ANSI A117.1 TOTAL: 5,192 F PROVIDED: 3 HEALTH DEPARTMENT HAMILTON COUNTY HEALTH DEPARTMENT - USE + OCCUPANCY: A-2 (ASSEMBLY- RESTAURANT USE) CAPACITY OF EGRESS COMPONENT 18030 FOUNDATION DRIVE, SUITE A NUMBER OF SEATS REQUIRED: 0.20" x 403 PERSONS = 80.E" NOBLESVILLE, INDIANA 46060 TYPE OF CONSTRUCTION PROVIDED (2) EXIT DOOR @ 34" + (1) EXIT DOOR @ 68" = 136" 20 (317) 776-8500 CLASSIFICATION 2B; PROTECTED 100 SF PER OCCUPANT health@)hamiltoncountyin.gov HEIGHT: NO MODIFICATION CONTINUITY AND COMPONENTS OFFICE 80 SF 1 AREA: NO MODIFICATION ALL ACCESSIBLE SPACES ARE PROVIDED WITH NOT LESS THAN *CODE LIST I SNOT NECESSARILY EXHAUSTIVE OFALL CODES HAVING JURISDICTION 100 SF PER OCCUPANT TWO ACCESSIBLE MEANS OF EGRESS AND ARE CONTINUOUS TO A PUBLIC WAY FIRE PROTECTION SYSTEMS 150 SF 30 6 AUTOMATIC SPRINKLER SYSTEM: YES PLUMBING FIXTURES FIRE ALARM SYSTEM: YES TOTAL OCCUPANTS ALLOCATED TO PLUMBING FIXTURE CALCULATIONS (INCLUDING PATIO) TOTAL INTERIOR OCC. 185 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FINISH REQUIREMENTS PATIO STRUCTURAL FRAME: 2 -HR WALL / CEILING VERTICAL EXITS: CLASS `B' LESS CONCENTRATED USE (15 SF BEARING WALLS (EXTERIOR) 2 -HR EXIT CORRIDORS: CLASS `B' BEARING WALLS (INTERIOR) 2 -HR OTHER ROOMS: CLASS `C' NON-BEARING WALLS (INT): 0 -HR FLOORS: CORRIDOR: DOC FF -1 145 * USED FOR PLUMBING FIXTURE FLOOR CONSTRUCTION: 2 -HR ROOMS: DOC FF -1 RESTROOM PLUMBING FIXTURES ROOF CONSTRUCTION: 1 -HR BUILDING OCCUPANCY CALCULATION = 185 + 33 = 218 50% MALE AND 50% FEMALE = 218/2 = 109 EACH SMOKE DEVELOPMENT RATING: 450 OR LESS 109/200 = 0.54 = 1 LAVATORY EACH OCCUPANCY LOAD CALCULATIONS CODE PLAN LEGEND SEE OCCUPANCY CALCULATION SCHEDULE (THIS SHEET) JBLE DOOR EXIT TH 68" CLEAR )PANTS -ECT BUILDING ► WILL BE DIMENSIONS OCCUPANCY CALCULATION ASSEMBLY AREA TOTAL SF MAX. SEAT OCCUPANTS* COUNT DINING AREAS LESS CONCENTRATED USE (15 SF PER OCCUPANT) 1,236 SF 83 73 BENCH TYPE SEATING - 51 34 18 LINEAL INCHES PER OCCUPANT FIXED SEATING - - - NUMBER OF SEATS KITCHEN + STAFF AREAS 2,000 SF 20 100 SF PER OCCUPANT OFFICE 80 SF 1 - F77771 100 SF PER OCCUPANT POTENTIAL WAITING 150 SF 30 6 5 SF PER OCCUPANT TOTAL INTERIOR OCC. 185 113 PATIO 33 32 LESS CONCENTRATED USE (15 SF PER OCCUPANT) TOTAL OCCUPANCY 218* 145 * USED FOR PLUMBING FIXTURE CALCULATION RESTROOM PLUMBING FIXTURES BUILDING OCCUPANCY CALCULATION = 185 + 33 = 218 50% MALE AND 50% FEMALE = 218/2 = 109 EACH 109/75 = 1.45 = 2 W.C. FIXTURES EACH 109/200 = 0.54 = 1 LAVATORY EACH CODE PLAN LEGEND — - — - — - — - — - — - — 1 HR RATED — — --- — — 2 HR RATED — ------------ 3 HR RATED EGRESS START — EGRESS END F.E. O FIRE EXTINGUISHER - SUGGESTED LOCATION CLASSIFICATION AND FINAL LOCATION SHALL BE SELECTED BY THE FIRE MARSHALL CANVAS DESIGN a Cl 11700160 CH q -T �_ G �11tfdl{llYl�tr,t KYLE P. SCHNEIDER LICENSE # 11700160 EXPIRES: 12.31.2019 PIES AND PINTS CLAY TERRACE 14550 CLAY TERRACE BLVD A29 CARMEL, INDIANA 46032 © 2018 BY: CANVAS DESIGN, LLC ALL RIGHTS RESERVED THE ARRANGEMENTSDEPICTEDHEREINARETHE SOLE PROPERTYOF CANVAS DESIGN LLC., AND MAY NOT BE REPRODUCEDWITHOUT ITS WRITTENPERMISSION NOTE: 1. ALL BIDDERSSHALLVISITTHE SITE AND BECOME FAMILIARW/THE EXISTING CONDITIONS AND REQUIREMENTSOF THE PROJECTAND SHALL NOTIFYTHE ARCHITECTOF ANY ERRORSAND OMISSIONS SUBSEQUENTLYDISCOVEREDIN THE CONTRACT DOCUMENTS. 2. THE CONTRACT DOCUMENTSARECOMPRISED OFTHE DRAWINGS AND THE PROJECT MANUAL IN THEIR ENTIRETY.THE INFORMATION IN THESE DOCUMENTS IS DEPENDENTUPON AND COMPLEMENTARYOF EACH OTHER. SEPARATIONOF THE CONTRACT DOCUMENTS SHALL NOT BE PERMITTED.IF THE CONTRACTOR CHOOSESTO SEPARATETHE DOCUMENTS, THEYDO SO ATTHEIROWN RISKAND EXPENSE. 3. ADDITIONALLY, SEE GENERAL INFORMATION ON "AO" SHEETS. 4. THE CLIENTACKNOWLEDGESTHE CONSULTANTS (ARCHITECT) DRAWINGSAND SPECIFICATION, INCLUDING ALL DOCUMENTSON ELECTRONICMEDIAAS INSTRUMENTSOF THE CONSULTANTS (ARCHITECT) PROFESSIONALSERVICE.THE CLIENTSHALL NOT REUSE OR MAKE OR PERMITTO BE MADE ANY MODIFICATION TO THE DRAWINGSAND SPECIFICATIONSWITHOUT THE PRIOR WRITTENAUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENTAGREESTO WAIVE ANY CLAIM AGAINSTTHE CONSULTANT (ARCHITECT) ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE OR MODIFICATIONOF THE DRAWINGSAND SPECIFICATIONS. 5. ARCHITECTCANNOT WAR RANTTH E ACCURACY OF DATA CONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL OR ALTEREDCADD DESIGN MATERIALSBYTHE USER OR OTHER PARITESWITHOUT THE REVIEWAND WRITTEN APPROVALOF THEARCHITECTSHALLBEATTHE SOLE RISK OF THE USER. FURTHERMORE, USERAGREESTO DEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESS FROM ALLCLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES, AND ATTORNEYS FEESARISING OUT OF THE MODIFICATIONOR REUSE OF THESE MATERIALS. 6. THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS ARE DIAGRAMMATICAND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONSOR CODIFIED REQUIREMENTS.THE DRAWINGS SHALL NOT BE SCALED. EXACTSTATEAND LOCALCODE REQUIREMENTS AND OTHER APPLICABLECODE REQUIRMENTSSHALLBE VERIFIEDBYAND ARE THE SOLE RESPONSIBILITYOFTHIS CONTRACTOR. ANY INFORMATION WHICH DIRECTLY CONFLICTSWITHANY OFTHESE CODES OR ANY DISCREPANCIESFOUND IN THE CONTRACT DOCUMENTS SHALLBEBROUGHT TOTHE ATTENTIONOFTHE PROJECT ARCHITECT. # Description Date A Permit Set PROJECT DATE: 02-05-18 PROJECT #: 17-001 LIFE SAFETY PLAN A0e05