Loading...
HomeMy WebLinkAbout10-A30104 -FINISH PLAN 1/4" = 1'-0" .u'°.) RELEASED FOR CONSTRUCTION Sohject to comipolianice with all regulations of State and (local Codes City of!Carmoll DATE: 03/14/18 Nick Mishler XA XB GENERAL NOTES - FINISH PLAN 1. GC TO VERIFY THAT ALL WALLS IN KITCHEN AREA ARE FACED WITH 5/8" FRT PLYWOOD 2. GC TO INSTALL BLACK FRP DIRECTLY OVER EXISTING WHITE FRP, WHERE DIRECTED BY TENANT. MAINTAIN ALL MANUFACTURERS STANDARDS. I, OUTDOOR EATING- -(UNCONDITIONED) F + - — 1 28 CNC -1 (FLOOR) FT FF 28 � � o + � SEE FINISH SCHEME SCHEDULE ON SHEET A3.02 FINISH PLAN - CODED NOTES 01 Ix POPLAR WOOD CAP (STAIN), SEE DETAILS A3.02 11 PLASTIC LAMINATE WORK SURFACE. 21 NOT USED 02 Ix POPLAR WOOD VERTICAL TRIM (STAIN), SEE DETAILS ON A3.02 12 CENTER TRELLIS, SEATING AND LIGHTING WITH NEW OVERHEAD DOOR. 22 INSTALL WATERPROOFING SEALER AT TOILET ROOMS AND RUN 4" UP ON ALL TOILET ROOM WALLS (SEE DETAIL E/A3.02) 03 CUSTOM MADE STAINLESS STEEL CAP AT HEAD AND JAMB OF 13 PAINTED "WHITE ELEPHANT" GRAPHIC BY TENANT (SEE INTERIOR PARTITION OPENINGS. RETURN 2" AT BOTH SIDES OF OPENINGS, G.C. ELEVATIONS) 23 VERTICAL STAINLESS STEEL CAP, FULL HEIGHT. TO VERIFY THAT CAP IS TIGHT TO ADJACENT WALL FINISH AND SEAL EDGESAS REQUIRED (CLEAR). 14 CUSTOM DOOR MOUNTED "M" SIGNAGE PROVIDED BY TENANT AND 24 OPEN TO EXTERIOR. INFILL WITH ROLL -DOWN CURTAIN SYSTEM (SEE A/A7.01 INSTALLED BY G.C. FOR ADDITIONAL INFORMATION) 04 INSTALL 2" STEEL ANGLES AT ALL OUTSIDE CORNERS OF RECLAIMED WOOD. RETURN WOOD FULL DEPTH OF JAMBS. 15 CUSTOM DOOR MOUNTED "W" SIGNAGE PROVIDED BY TENANT AND 25 36" WIDE PREFINISHED ALUMINUM GATE WITH PANIC HARDWARE (BLACK). INSTALLED BY G.C. 05 INSTALL 2" STEEL ANGLE AT OUTSIDE CORNER. 26 36" HIGH 1X3 STAINED MAHOGONY WOOD RAIL OVER 2"X2" STEEL POSTS. 16 PROVIDE (1) UNDERCOUNTER PURSE HOOK PER BAR STOOL, PROVIDE 1/8" METAL CABLE AT 4" O.C. BELOW. 06 G.C. TO PROVIDE STAINLESS STEEL TRIM AT VERTICAL GAPS BETWEEN TYPICAL (SEE DETAIL C/A7.X) COOLER AND PARTITION, SEAL EDGES. 27 36" HIGH 1X3 STAINED MAHOGONEY WOOD RAIL ATTACHED TO STEEL 17 INSTALL CAST IRON PIPE GUARDAT LIGHTSIWTCH BANK. VERIFY IN FIELD, COLUMNS. PROVIDE 1/8" METAL CABLE AT 4" O.C. BELOW. 07 THIN BRICK TO RETURN FULL DEPTH OF WALL. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 28 1X6 IPE OVER 2X BLOCKING OVER FRT PLYWOOD, COLUMN WRAP. (SEE 18 TUBE STEEL FRAME WITH WIRE MESH INSET AT V-0" AFF, BY GC, COORDINATE A7.01 AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION). 08 PROVIDE MANUFACTURER'S TRANSITION STRIP AT EDGEOF EPDXY WITH OWNER. PAINT PT -4 FLOORING 29 FABRIC VALENCE. GC TO COORDINATE INK APPLIED GRAPHICS 19 WRAP DINING ROOM SIDE OF WINDOW & DOOR WITH Ix RECLAIMED WITH OWNER 09 SYNTHETIC STONE COUNTERTOP WOOD CASEMENT TRIM (SEE ELEVATIONS). 30 2X BLOCKING 10 STAINLESS STEEL COUNTERTOP 20 PROVIDE Ix RECLAIMED WOOD AT INSIDE FACE OF HEAD AND JAMBS. CANVAS DESIGN �,�wattttllf�ffrr�rrrr a CI 11700160 CH q1` �i0ffll Itlttrt KYLE P. SCHNEIDER LICENSE # 11700160 EXPIRES: 12.31.2019 PIES AND PINTS CLAY TERRACE 14550 CLAY TERRACE BLVD A29 CARMEL, INDIANA 46032 © 2018 BY: CANVAS DESIGN, LLC ALLRIGHTS RESERVED THE ARRANGEMENTSDEPICTEDHEREINARETHE SOLE PROPERTYOF CANVAS DESIGN LLC., AND MAY NOT BE REPRODUCEDWITHOUT ITS WRITTENPERMISSION NOTE: 1. ALL BIDDERSSHALLVISITTHE SITE AND BECOME FAMILIARW/THE EXISTING CONDITIONS AND REQUIREMENTSOF THE PROJECTAND SHALL NOTIFYTHE ARCHITECTOF ANY ERRORSAND OMISSIONS SUBSEQUENTLYDISCOVEREDIN THE CONTRACT DOCUMENTS. 2. THE CONTRACT DOCUMENTSARECOMPRISED OFTHE DRAWINGS AND THE PROJECT MANUAL IN THEIR ENTIRETY.THE INFORMATION IN THESE DOCUMENTS IS DEPENDENTUPON AND COMPLEMENTARYOF EACH OTHER. SEPARATIONOF THE CONTRACT DOCUMENTS SHALL NOT BE PERMITTED.IF THE CONTRACTOR CHOOSESTO SEPARATETHE DOCUMENTS, THEYDO SO ATTHEIROWN RISKAND EXPENSE. 3. ADDITIONALLY, SEE GENERAL INFORMATION ON "AO" SHEETS. 4. THE CLIENTACKNOWLEDGESTHE CONSULTANTS (ARCHITECT) DRAWINGSAND SPECIFICATION, INCLUDING ALL DOCUMENTSON ELECTRONICMEDIAAS INSTRUMENTSOF THE CONSULTANTS (ARCHITECT) PROFESSIONALSERVICE.THE CLIENTSHALL NOT REUSE OR MAKE OR PERMITTO BE MADE ANY MODIFICATION TO THE DRAWINGSAND SPECIFICATIONSWITHOUT THE PRIOR WRITTENAUTHORIZATIONOF THE CONSULTANT (ARCHITECT). THE CLIENTAGREESTO WAIVE ANY CLAIM AGAINSTTHE CONSULTANT (ARCHITECT) ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE OR MODIFICATIONOF THE DRAWINGSAND SPECIFICATIONS. 5. ARCHITECTCANNOT WAR RANTTH E ACCURACY OF DATA CONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL OR ALTEREDCADD DESIGN MATERIALSBYTHE USER OR OTHER PARITESWITHOUT THE REVIEWAND WRITTEN APPROVALOF THEARCHITECTSHALLBEATTHE SOLE RISK OF THE USER. FURTHERMORE, USERAGREESTO DEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESS FROM ALLCLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES, AND ATTORNEYS FEESARISING OUT OF THE MODIFICATIONOR REUSE OF THESE MATERIALS. 6. THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS ARE DIAGRAMMATICAND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONSOR CODIFIED REQUIREMENTS.THE DRAWINGS SHALL NOT BE SCALED. EXACTSTATEAND LOCALCODE REQUIREMENTS AND OTHER APPLICABLECODE REQUIRMENTSSHALLBE VERIFIEDBYAND ARE THE SOLE RESPONSIBILITYOF THIS CONTRACTOR. ANY INFORMATION WHICH DIRECTLY CONFLICTSWITHANY OFTHESE CODES OR ANY DISCREPANCIESFOUND IN THE CONTRACT DOCUMENTS SHALLBEBROUGHT TOTHE ATTENTIONOFTHE PROJECT ARCHITECT. # Description Date A Permit Set PROJECT DATE: 02-05-18 PROJECT #: 17-001 FINISH PLAN A3.01 uC'� P'.1.1 1il:, il:, a,, III''"''Ihdl