HomeMy WebLinkAbout33-E11'a' 'c' 'd' 'e' 'f'
VESTIBULE
LIGHTING
BAR/WAITING
TRACK
BAR
PENDANT LTG
DINING TABLE
PENDANTS
RR
CORRIDOR LTG
'm'
DINING
DOWN LIGHTS
'n'
DINING
TRACK
'j'
BEER GARDEN
DOWN LTG
't'
BEER GARDEN
WALL SCONCE
BEER GARDEN
PENDANTS
'q'
DINING FEAT.
PENDANT
BEER GARDEN
STRING LTG
'h' 'k'
DINING
CEILING FANS
DINING CLG
PENDANTS
'b'
HOST
PENDANT
BAR
CEILING FANS
'r' 's' 'v'
KITCHEN
LIGHTING
'g'
'p'
PATIO STRING
LIGHTING
'o'
'w' 'X'
3-WAY 3-WAY
KITCHEN
LIGHTING
DINING
WALL SCONCE
PATIO
CEILING FANS
NOTES:
1) ALL FIXTURE MOUNTING, MATERIALS, PARTS, AND INSTALLATION BY EC.
2) EC SHALL COORDINATE PAINTING OF THREADED ROD, UNISTRUT, AND
MISC PARTS WITH GC. COLOR TO MATCH CEILING PAINT.
3) EC SHALL ROUTE TRACK BRANCH CIRCUIT DOWN THREADED ROD.
4) MINIMUM OF 2 SUPPORTS PER 8' OR SHORTER OF TRACK SECTION.
UNISTRUT ON BOTTOM OF
JOISTS AS REQUIRED DEPENDING
ON CEILING LOCATION
DUCTWORK
3/8" THREADED ROD WITH WASHERS
AND NUTS TO HOLD TIGHT IN PLACE.
CONFIRM LENGTH IN FIELD.
XA XB XD XE
XF XG XH XI XJ XK XL XM
XC
X1
X2
X4
X5
X6
X7
X8
C
A
B
R3 R3 R3 R3 R3 R3
R3 R3
R3 R3 R3
R3
R3
R3
R3
R3
R3
R3
R3
R3
1
3 3W 3W
2
R1 R1 R1 R1 R1 R1 R1 R1
R1
R1
OCC
DIM
R4 R4
R4
W1
W1 W1 W1 W1 W1
P4 P4
P4 P4
P4
P4
S1 S1 S1
S1
S1
R1
R1
R1
R1 R1 R1
P5 P5 P5 P5
R1 R1 R1 R1 R1
R1 R1
R1 R1
P2
T1 T1
T1
T1 T1 T1
T1
T1
T1
S2
S2 S2
S2
S2
S2 S2
S2
S2
S2
S2 S2
S2
S2 S2
S2
S2
S2
X1
X2
X2
X1
X1
X3
X3
X3
X3
X3
R2
R2
R2
R2
R2
R2
R2
R2
OS
OS
5
4
4
4
4
F1
F1
F1 F1
F1 F1
P6
P6
P6
P6
P6
P6
P6
P6
P6
P6
P3 P3 P3 P3 P3 P3 P3 P3
P3
P3
5
X3
X1
X1
X1
X1
X3
SL
F1
P1
L-2
SW-'a'
W2 W2
W2
W2
6
6
6
6
6
6
7
SL
L-1
SW-'c'
3W
3W
SW-'b'
L-4
SW-'m'
SW-'k'
SW-'j'
L-6
SW-'h'
L-8
L-3
SW-'o'
SW-'f'
L-5
L-7
SW-'e'
L-9
SW-'p'
L-11
SW-'g'
L-13
SW-'q'
SW-'v'
L-15
SW-'n'
SW-'p'
L-17
L-19
SW-'t'
L-21
SW-'q'
L-12
L-10
J
8
L-14
ML
J
8
L-14
ML
10 10
10
10
10
F1
W1
W1
W1
W1
10
SW-'d'
J
L-18
9
S3 S3 S3 S3
L-20
MENS
107
WOMENS
108
RESTROOM
CORRIDOR
106
BAR
105
WAIT STATION
109
EXPO
112
BAR DINING
104
DINING
111
HOST
101
WAITING
102
BEER GARDEN
103
COOLER
122
BEER COOLER
121
OFFICE
114
DISH WASH
119
STORAGE
117
PREP
115
PIZZA PREP
116
OUTDOOR
SEATING
110
VESTIBULE
100
WAIT STATION
113
STORAGE
118
UTILITY
120
STORAGE
123
R1 R1
1
LIGHTING - FLOOR PLAN
1/4" = 1'-0"
INT. PROJ. #: 17-SCH-01
DRAWING ISSUE:
DATE # DESCRIPTION
02/05/18 PERMIT SET
PIES & PINTS - CARMEL, IN
14550 CLAY TERRACE BLVD, STE 100
CARMEL, IN 46032
3982 POWELL RD, STE #425
POWELL, OHIO 43065
WWW.CATALYSTENG.COM (440) 785-2043
P
1. TO 3-WAY SWITCH AT OTHER SIDE OF KITCHEN.
2. DINING AREA SWITCHBANK. REFER TO DETAIL ON THIS SHEET.
3. EXISTING EGRESS FIXTURE/EXIT VERIFY FIXTURE IS IN PROPER WORKING ORDER AND WIRE
THROUGH LOCAL LIGHT CIRCUIT AHEAD OF SWITCHING.
4. EXISTING HOOD TO REMAIN AS IS SHOWN FOR REFERENCE.
5. EXISTING LIGHTING WITHIN COOLER TO REMAIN AS IS.
6. DEMOLISH ALL EXISTING LIGHTING AND ASSOCIATED WIRING BACK TO SOURCE. REPLACE WITH
NEW LIGHTING AS SHOWN.
7. PROVIDE LIGHTING CONTROL PANEL SIMILAR TO WATTSTOPPER LP8S-8-15 FOR AUTOMATIC
LIGHTING CONTROL OF FIXTURES.
8. WIRE THOUGH TIMECLOCK.
9. FURNISH AND INSTALL LED ROPE LIGHTING MOUNTED TO UNDERSIDE OF COUNTERTOP AS SHOWN.
FIELD VERIFY EXACT CONTROLS AND POWER REQUIREMENTS. FURNISH AND INSTALL JUNCTION
BOX FOR ROPE LIGHTING POWER ON ONE END.
10. INFRARED HEATERS SHOWN FOR REFERENCE. REFER TO POWER PLAN.
# CODED NOTES:
GENERAL NOTES
1. ALL WORK DESCRIBED WITHIN THIS SET OF DOCUMENTS SHALL BE PERFORMED TO MEET THE
REQUIREMENTS OF CODE CURRENTLY ADOPTED BY AUTHORITY HAVING JURISDICTION. THIS SHALL
NOT BE LIMITED TO THE NATIONAL ELECTRICAL CODE, BUT TO ALL APPLICABLE CODES SUCH AS THE
BUILDING CODE, FUEL GAS CODE, NFPA, ETC.
2. DRAWINGS ARE SCHEMATIC IN NATURE AND GRAPHICALLY REPRESENT THE INTENT OF ELECTRICAL
SYSTEM INSTALLATION. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM TO MEET THIS INTENT WHETHER INDICATED ON
THE DRAWINGS OR OTHERWISE.
3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH EXISTING CONDITIONS AND OTHER TRADES
BEFORE INSTALLING DUCTWORK AND EQUIPMENT. CHANGES INCURRED FROM FAILURE TO
COORDINATE WITH THESE CONDITIONS SHALL BE AT THE ELECTRICAL CONTRACTOR'S EXPENSE.
4. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR MOUNTING HEIGHTS.
5. ALL EGRESS/EXIT LIGHTING SHALL BE WIRED AHEAD OF LOCAL SWITCHING WITHIN SPACE FIXTURES
SERVES.
2
SWITCHBANK DETAIL
N.T.S.
E1-1
LIGHTING
FLOOR PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND
JUNCTION BOX
DISCONNECT
3PH MOTOR
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
DATA/TELEPHONE OUTLET
J
M
FLOOR MOUNTED RECEPTACLE
STOREFRONT RECEPTACLE
PULL STATION (MOUNT AT 44" AFF)
HORN/STROBE DEVICE (MOUNT AT 80" AFF)
DUPLEX RECEPTACLE MTD AT 42" AFF (UNO)
ELECTRICAL ABBREVIATIONS
DEMOLISHED
GROUND FAULT INTERRUPTER
WEATHERPROOF
DOMESTIC WATER HEATER
ROOFTOP UNIT
(D)
GFI
WP
DWH
RTU
EF EXHAUST FAN
OC OCCUPANCY SENSOR
(E) EXISTING TO REMAIN
LIGHTING SYMBOLS
SINGLE POLE SWITCH
THREE WAY SWITCH
0-10V DIMMER. COORDINATE TYPE PER MANUFACTURER RECOMMENDATIONS
VACANCY SENSOR, CEILING MTD. DUAL TECHNOLOGY.
OCCUPANCY SENSOR, CEILING MTD. DUAL TECHNOLOGY.
DIM
OS
3W
NOTES:
1. STRAIGHT LINES BETWEEN LIGHT FIXTURES INDICATE LIGHTS THAT ARE SWITCHED TOGETHER.
2. ARCED LINES BETWEEN LIGHT FIXTURES INDICATE LIGHTS THAT ARE CIRCUITED TOGETHER.
VS
OCCUPANCY SENSOR
OCC
HORN/STROBE DEVICE (CEILING MOUNTED)
DOUBLE DUPLEX RECEPTACLE MTD AT 42" AFF (UNO)
MOUNT RECEPTACLE HORIZONTALLY
PROVIDE USB RECEPTACLE SIMILAR TO LEVITON T5632
H
USB
ISOLATED GROUND
IG
GFCI PROTECTED RECEPTACLE
GFI
3
TRACK MOUNTING DETAIL
N.T.S.
03/14/18
Nick Mishler