Loading...
HomeMy WebLinkAbout33-E11'a' 'c' 'd' 'e' 'f' VESTIBULE LIGHTING BAR/WAITING TRACK BAR PENDANT LTG DINING TABLE PENDANTS RR CORRIDOR LTG 'm' DINING DOWN LIGHTS 'n' DINING TRACK 'j' BEER GARDEN DOWN LTG 't' BEER GARDEN WALL SCONCE BEER GARDEN PENDANTS 'q' DINING FEAT. PENDANT BEER GARDEN STRING LTG 'h' 'k' DINING CEILING FANS DINING CLG PENDANTS 'b' HOST PENDANT BAR CEILING FANS 'r' 's' 'v' KITCHEN LIGHTING 'g' 'p' PATIO STRING LIGHTING 'o' 'w' 'X' 3-WAY 3-WAY KITCHEN LIGHTING DINING WALL SCONCE PATIO CEILING FANS NOTES: 1) ALL FIXTURE MOUNTING, MATERIALS, PARTS, AND INSTALLATION BY EC. 2) EC SHALL COORDINATE PAINTING OF THREADED ROD, UNISTRUT, AND MISC PARTS WITH GC. COLOR TO MATCH CEILING PAINT. 3) EC SHALL ROUTE TRACK BRANCH CIRCUIT DOWN THREADED ROD. 4) MINIMUM OF 2 SUPPORTS PER 8' OR SHORTER OF TRACK SECTION. UNISTRUT ON BOTTOM OF JOISTS AS REQUIRED DEPENDING ON CEILING LOCATION DUCTWORK 3/8" THREADED ROD WITH WASHERS AND NUTS TO HOLD TIGHT IN PLACE. CONFIRM LENGTH IN FIELD. XA XB XD XE XF XG XH XI XJ XK XL XM XC X1 X2 X4 X5 X6 X7 X8 C A B R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3 1 3 3W 3W 2 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 OCC DIM R4 R4 R4 W1 W1 W1 W1 W1 W1 P4 P4 P4 P4 P4 P4 S1 S1 S1 S1 S1 R1 R1 R1 R1 R1 R1 P5 P5 P5 P5 R1 R1 R1 R1 R1 R1 R1 R1 R1 P2 T1 T1 T1 T1 T1 T1 T1 T1 T1 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 X1 X2 X2 X1 X1 X3 X3 X3 X3 X3 R2 R2 R2 R2 R2 R2 R2 R2 OS OS 5 4 4 4 4 F1 F1 F1 F1 F1 F1 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 5 X3 X1 X1 X1 X1 X3 SL F1 P1 L-2 SW-'a' W2 W2 W2 W2 6 6 6 6 6 6 7 SL L-1 SW-'c' 3W 3W SW-'b' L-4 SW-'m' SW-'k' SW-'j' L-6 SW-'h' L-8 L-3 SW-'o' SW-'f' L-5 L-7 SW-'e' L-9 SW-'p' L-11 SW-'g' L-13 SW-'q' SW-'v' L-15 SW-'n' SW-'p' L-17 L-19 SW-'t' L-21 SW-'q' L-12 L-10 J 8 L-14 ML J 8 L-14 ML 10 10 10 10 10 F1 W1 W1 W1 W1 10 SW-'d' J L-18 9 S3 S3 S3 S3 L-20 MENS 107 WOMENS 108 RESTROOM CORRIDOR 106 BAR 105 WAIT STATION 109 EXPO 112 BAR DINING 104 DINING 111 HOST 101 WAITING 102 BEER GARDEN 103 COOLER 122 BEER COOLER 121 OFFICE 114 DISH WASH 119 STORAGE 117 PREP 115 PIZZA PREP 116 OUTDOOR SEATING 110 VESTIBULE 100 WAIT STATION 113 STORAGE 118 UTILITY 120 STORAGE 123 R1 R1 1 LIGHTING - FLOOR PLAN 1/4" = 1'-0" INT. PROJ. #: 17-SCH-01 DRAWING ISSUE: DATE # DESCRIPTION 02/05/18 PERMIT SET PIES & PINTS - CARMEL, IN 14550 CLAY TERRACE BLVD, STE 100 CARMEL, IN 46032 3982 POWELL RD, STE #425 POWELL, OHIO 43065 WWW.CATALYSTENG.COM (440) 785-2043 P 1. TO 3-WAY SWITCH AT OTHER SIDE OF KITCHEN. 2. DINING AREA SWITCHBANK. REFER TO DETAIL ON THIS SHEET. 3. EXISTING EGRESS FIXTURE/EXIT VERIFY FIXTURE IS IN PROPER WORKING ORDER AND WIRE THROUGH LOCAL LIGHT CIRCUIT AHEAD OF SWITCHING. 4. EXISTING HOOD TO REMAIN AS IS SHOWN FOR REFERENCE. 5. EXISTING LIGHTING WITHIN COOLER TO REMAIN AS IS. 6. DEMOLISH ALL EXISTING LIGHTING AND ASSOCIATED WIRING BACK TO SOURCE. REPLACE WITH NEW LIGHTING AS SHOWN. 7. PROVIDE LIGHTING CONTROL PANEL SIMILAR TO WATTSTOPPER LP8S-8-15 FOR AUTOMATIC LIGHTING CONTROL OF FIXTURES. 8. WIRE THOUGH TIMECLOCK. 9. FURNISH AND INSTALL LED ROPE LIGHTING MOUNTED TO UNDERSIDE OF COUNTERTOP AS SHOWN. FIELD VERIFY EXACT CONTROLS AND POWER REQUIREMENTS. FURNISH AND INSTALL JUNCTION BOX FOR ROPE LIGHTING POWER ON ONE END. 10. INFRARED HEATERS SHOWN FOR REFERENCE. REFER TO POWER PLAN. # CODED NOTES: GENERAL NOTES 1. ALL WORK DESCRIBED WITHIN THIS SET OF DOCUMENTS SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF CODE CURRENTLY ADOPTED BY AUTHORITY HAVING JURISDICTION. THIS SHALL NOT BE LIMITED TO THE NATIONAL ELECTRICAL CODE, BUT TO ALL APPLICABLE CODES SUCH AS THE BUILDING CODE, FUEL GAS CODE, NFPA, ETC. 2. DRAWINGS ARE SCHEMATIC IN NATURE AND GRAPHICALLY REPRESENT THE INTENT OF ELECTRICAL SYSTEM INSTALLATION. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM TO MEET THIS INTENT WHETHER INDICATED ON THE DRAWINGS OR OTHERWISE. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH EXISTING CONDITIONS AND OTHER TRADES BEFORE INSTALLING DUCTWORK AND EQUIPMENT. CHANGES INCURRED FROM FAILURE TO COORDINATE WITH THESE CONDITIONS SHALL BE AT THE ELECTRICAL CONTRACTOR'S EXPENSE. 4. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR MOUNTING HEIGHTS. 5. ALL EGRESS/EXIT LIGHTING SHALL BE WIRED AHEAD OF LOCAL SWITCHING WITHIN SPACE FIXTURES SERVES. 2 SWITCHBANK DETAIL N.T.S. E1-1 LIGHTING FLOOR PLAN 1/4" = 1'-0" ELECTRICAL LEGEND JUNCTION BOX DISCONNECT 3PH MOTOR DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DATA/TELEPHONE OUTLET J M FLOOR MOUNTED RECEPTACLE STOREFRONT RECEPTACLE PULL STATION (MOUNT AT 44" AFF) HORN/STROBE DEVICE (MOUNT AT 80" AFF) DUPLEX RECEPTACLE MTD AT 42" AFF (UNO) ELECTRICAL ABBREVIATIONS DEMOLISHED GROUND FAULT INTERRUPTER WEATHERPROOF DOMESTIC WATER HEATER ROOFTOP UNIT (D) GFI WP DWH RTU EF EXHAUST FAN OC OCCUPANCY SENSOR (E) EXISTING TO REMAIN LIGHTING SYMBOLS SINGLE POLE SWITCH THREE WAY SWITCH 0-10V DIMMER. COORDINATE TYPE PER MANUFACTURER RECOMMENDATIONS VACANCY SENSOR, CEILING MTD. DUAL TECHNOLOGY. OCCUPANCY SENSOR, CEILING MTD. DUAL TECHNOLOGY. DIM OS 3W NOTES: 1. STRAIGHT LINES BETWEEN LIGHT FIXTURES INDICATE LIGHTS THAT ARE SWITCHED TOGETHER. 2. ARCED LINES BETWEEN LIGHT FIXTURES INDICATE LIGHTS THAT ARE CIRCUITED TOGETHER. VS OCCUPANCY SENSOR OCC HORN/STROBE DEVICE (CEILING MOUNTED) DOUBLE DUPLEX RECEPTACLE MTD AT 42" AFF (UNO) MOUNT RECEPTACLE HORIZONTALLY PROVIDE USB RECEPTACLE SIMILAR TO LEVITON T5632 H USB ISOLATED GROUND IG GFCI PROTECTED RECEPTACLE GFI 3 TRACK MOUNTING DETAIL N.T.S. 03/14/18 Nick Mishler