HomeMy WebLinkAboutA141 REFLECTED CEILING PLANEXAM 1 103 EXAM 2 104 TREATMENT 120 STORAGE 119 OFFICE 118 WAITING 100 ESTHETICIAN 109 FRONT OFFICE 101 CLEAN LINEN 107 TLT- PATIENT 108 SOILED 113 OFFICE/ CONSULT 110 BIO 112 CHECK OUT 102 CORR. 114 EXAM 3 105 STORAGE 111 MA STATION 106 OFFICE 117 BREAK ROOM 116 CORRIDOR 121 8' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 3' - 0" 8' - 0" GB-1 9' - 0" APC-1 1 1 1 1 1 1 1 1 1 1 2 3 3 3 3 3 NOT IN SCOPE STAIR 4 4 4 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 EXIST. EQ EQ EQ EQ DESIGN BUILD HVAC, ELECTRICAL, PLUMBING NOTES GENERAL SCOPE: THE HVAC, ELECTICAL/VOICE/DATA AND PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATED OTHERWISE. DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. CONTRACTORS SHALL FURNISH AND INSTALL ALL NECESSARY WORK AND COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. CONTRACTORS TO SUBMIT ALL FINAL HVAC DRAWINGS TO LANDLORD AND OWNER FOR REVIEW AND MUST RECEIVE FINAL APPROVAL FROM BOTH PARTIES PRIOR TO CONSTRUCTION. DESIGN/BUILD SUBCONTRACTORS SHALL REVIEW BUILDING SYSTEM SCOPE DOCUMENTS AND OFFER ANY MODIFICATIONS THAT MAY BE APPROPRIATE FOR COMPLETE AND OPERABLE SYSTEMS. HVAC: • THE HVAC CONTRACTOR SHALL "BALANCE" THE SYSTEM PRIOR TO THE TENANT'S MOVE-IN DATE. • THE HVAC CONTRACTOR SHALL VERIFY WITH THE TENANT HOW THE SYSTEM IS TO BE "ZONED" AND IDENTIFY THE LOCATION OF ALL THERMOSTATS. • IN EXISTING SPACES BEING FULLY OR PARTIALLY DEMOLISHED, ALL HVAC SUPPLY AND RETURN DIFFUSERS SHALL BE NEW. • PROVIDE "SOUND BOOTS" IN ALL RETURN AIR GRILLES IN ALL AREAS. • ALL HVAC DIFFUSERS, THERMOSTATS, GRILLES, AND EXHAUST FANS TO MATCH BUILDING STANDARD. • REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR THERMOSTAT MOUNTING HEIGHTS. • THE HVAC CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR IN REGARDS TO ELECTRICAL ROUGH-IN NECESSARY TO POWER HVAC SYSTEMS OR DEVICES. ELECTRICAL SYSTEMS: • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THE AUDIO/VISUAL SYSTEMS, SECURITY SYSTEMS, AND IT SYSTEMS. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. • THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS AND CIRCUITS. • THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. • REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR DEVICE MOUNTING HEIGHTS. • PROVIDE AND INSTALL ROUGH-INS AS REQUIRED FOR AUDIO/VISUAL, SECURITY SYSTEMS, AND IT SYSTEMS. PLUMBING: • ALL NEW AND EXISTING HOT WATER LINES SHALL BE INSULATED. • ALL NEW AND EXISTING PVC OVERHEAD PIPING ABOVE THE CEILINGS SHALL BE WRAPPED WITH "FIRE TAPE". • ALL FIXTURES TO BE WHITE. ALL EXPOSED PIPING AND SUPPLY FITTINGS SHALL BE CHROMIUM PLATED. ALL PIPING WALL PENETRATIONS SHALL HAVE CHROMIUM PLATED ESCUTCHEONS. • ALL PIPING SHOWN ON PLUMBING DRAWINGS IS DIAGRAMATIC. FIELD VERIFY FOR EXACT ROUTING. • ACCESSIBLE PLUMBING FIXTURES SHALL COMPLY WITH ADA. • AFTER COMPLETION OF THE WATER SUPPLY SYSTEM ROUGH-IN AND BEFORE THE FIXTURES HAVE BEEN SET, THE ENTIRE COLD AND HOT WATER SUPPLY SYSTEM SHALL BE PRESSURE TESTED TO AT LEAST 100 PSI AND BE FREE OF LEAKS. • THE ENTIRE DOMESTIC WATER SUPPLY SYSTEM SHALL BE THOROUGHLY STERILIZED WITH A SOLUTION OF 50 PARTS PER MILLION CHLORINE IN ACCORDANCE WITH THE RECOMMENDATION OF THE MANUFACTURER FOR SUCH USE. • REFER TO TYPICAL MOUNTING SHEET FOR PLUMBING FIXTURE MOUNTING HEIGHTS. • PROVIDE AND INSTALL "HANDI-LAV-GUARD" INSULATION AT EACH LAVATORY - TRUEBRO INC. - WHITE (VERIFY MODEL NUMBER) • PROVIDE AND INSTALL SHUT-OFF-VALVES TO ISOLATE ALL PLUMBING WITHIN SUITE. AUDIO VISUAL SYSTEMS: • THE PROJECT MANAGER IS TO PROVIDE AND COORDINATE ALL AV VENDORS WITH THE GENERAL CONTRACTOR FOR ALL AUDIO VISUAL, SECURITY ITEMS, INCLUDING, BUT NOT LIMITED TO: TELEVISION JACKS, SPEAKERS, AUDIO SOURCES, NURSE CALL DEVICES, AND ELECTRIC DOOR HARDWARE. • THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL ITEMS. ALL SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. • THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. • THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR FOR ELECTRICAL ROUGH-INS NECESSARY TO POWER AUDIO VISUAL SYSTEMS DEVICES. SECURITY SYSTEMS: • THE SECURITY SYSTEM CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL FIRE ALARM DEVICES, SECURITY DEVICES, SMOKE DETECTORS, CARD READERS AND FIRE SUPRESSION SYSTEMS. SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. • THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. • THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE BLOCKING WITH THE GENERAL CONTRACTOR FOR DEVICES REQUIRING SUPPORT. • THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR REGARDING ELECTRICAL ROUGH-INS NECESSARY TO POWER ALL SECURITY SYSTEMS AND DEVICES. NEW GYP BOARD CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION NEW APC CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION NEW LIGHTING SWITCH: X - NUMBER OF POLES SCHEMATIC WIRE EXHAUST DIFFUSER - MATCH BUILDING STANDARD CEILING SYMBOLS x RETURN DIFFUSER - MATCH BUILDING STANDARD NEW SUPPLY DIFFUSER - MATCH BUILDING STANDARD NEW LIGHT FIXTURE: - 6" RECESSED LED CAN LIGHT - REFER TO LIGHTING PLAN NEW LIGHT FIXTURE - OCCUPANCY SENSOR - 2' WIDE WALL MOUNT LIGHT FIXTURE - REFER TO LIGHTING PLAN 2' NEW LIGHT FIXTURE - 2'x4' LAY-IN INDIRECT FLUORESCENT - REFER TO LIGHTING PLAN NEW LIGHT FIXTURE - 2'x4' LAY-IN TROFFER - REFER TO LIGHTING PLAN NEW EXIT SIGN FIXTURE - CEILING MOUNT LED EXIT SIGN - REFER TO LIGHTING PLAN EXISTING APC CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION EXISTING GYP BOARD CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:56 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A141 REFLECTED CEILING PLAN 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 1/4" = 1'-0" ? 1 REFLECTED CEILING PLAN REFLECTED CEILING PLAN NOTES 1 MECHANICAL AND LIGHT FIXTURES TO REMAIN AS IS UNLESS NOTED OTHERWISE. 2 CEILING MOUNTED EXAM LIGHT PROVIDED BY TENANT, INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND INSTALL UNISTRUT CEILING MOUNTED LIGHT SUPPORT. CONTRACTOR TO PROVIDE 120V DEDICATED CIRCUIT FOR FIXTURE. 3 TIE EXTENDED BULKHEAD INTO EXISTING BULKHEAD. MATCH HEIGHT, RADIAL CURVATURE, AND TYPE OF EXISTING, ADJACENT CEILING TYPE. 4 LIGHT TO BE ON OCCUPANCY SENSOR. 5 ROOM TO RECEIVE 24-7 EXHAUST FAN. 6 INSTALL SALVAGED LIGHT FIXTURE IN ROOM.