HomeMy WebLinkAboutE101 ELECTRICAL SYSTEMS PLAN104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE 117 159 SF BREAK ROOM 116 413 SF CORRIDOR 121 N +44, GFI +44, GFI +72" N N N N N N N N N N N N N N N N N N N N N N N N N N N N N +44, GFI +44, GFI N N N N NOT IN SCOPE STAIR TV +72" N N N N N N N N N N N N N N N N N N N N N N N N, D Xref S:\Operations\Active Projects\17124 Xref - St. S:V \Operations\- Dr. Paul Plastics\Active Projects\1 BIM\1.5 17124 Transfers\- St. V 20180116 - Dr. Paul - Plastics\Dr-Paul Plastic 1 BIM\1.Surgery-5 Transfers\Suite 20180116 140 E101- - Dr-ELECTRICAL Paul Plastic Surgery-& SYSTEMS Suite PLAN-140 - E101- Legend ELECTRICAL - DESIGN BUILD & SYSTEMS NOTES.PLAN-dwg Legend - DESIGN BUILD NOTES.dwg DEDICATED DUPLEX FOR FRIDGE. DEDICATED DUPLEX FOR MICROWAVE ABOVE SWITCH AND RECEPTACLE FOR DISPOSAL. GFI H H H H H N N N N N N N N N N N,D N N GFI +44 H N N N D D D H N N H N N H N N TV GFI POWER/DATA LEGEND SYMBOL NAME RESPONSIBILITY ELECTRICAL POWER PANEL ELECTRICAL TELEVISION JACK CONTRACTOR DUPLEX OUTLET ELECTRICAL DUPLEX OUTLET - GFI ELECTRICAL DATA OUTLET AHIS D DUPLEX OUTLET - DEDICATED ELECTRICAL EXIT EMERGENCY EXIT SIGN ELECTRICAL QUAD OUTLET ELECTRICAL V WALL MOUNTED VISUAL ALARM DEVICE ELECTRICAL DESIGN BUILD ELECTRICAL NOTES • • • • • • • • ‡ • • • • • GENERAL SCOPE: THE HVAC, ELECTICAL/VOICE/DATA AND PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATED OTHERWISE. DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. CONTRACTORS SHALL FURNISH AND INSTALL ALL NECESSARY WORK AND COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. CONTRACTORS TO SUBMIT ALL FINAL HVAC DRAWINGS TO LANDLORD AND OWNER FOR REVIEW AND MUST RECEIVE FINAL APPROVAL FROM BOTH PARTIES PRIOR TO CONSTRUCTION. DESIGN/BUILD SUBCONTRACTORS SHALL REVIEW BUILDING SYSTEM SCOPE DOCUMENTS AND OFFER ANY MODIFICATIONS THAT MAY BE APPROPRIATE FOR COMPLETE AND OPERABLE SYSTEMS. ELECTRICAL SYSTEMS: THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THE AUDIO/VISUAL SYSTEMS, SECURITY SYSTEMS, AND IT SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS AND CIRCUITS. THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR DEVICE MOUNTING HEIGHTS. PROVIDE AND INSTALL ROUGH-INS AS REQUIRED FOR AUDIO/VISUAL, SECURITY SYSTEMS, AND IT SYSTEMS. AUDIO VISUAL SYSTEMS: THE PROJECT MANAGER IS TO PROVIDE AND COORDINATE ALL AV VENDORS WITH THE GENERAL CONTRACTOR FOR ALL AUDIO VISUAL, SECURITY ITEMS, INCLUDING, BUT NOT LIMITED TO: TELEVISION JACKS, SPEAKERS, AUDIO SOURCES, NURSE CALL DEVICES, AND ELECTRIC DOOR HARDWARE. THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL ITEMS. ALL SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR FOR ELECTRICAL ROUGH-INS NECESSARY TO POWER AUDIO VISUAL SYSTEMS DEVICES. SECURITY SYSTEMS: THE SECURITY SYSTEM CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL FIRE ALARM DEVICES, SECURITY DEVICES, SMOKE DETECTORS, CARD READERS AND FIRE SUPRESSION SYSTEMS. SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE BLOCKING WITH THE GENERAL CONTRACTOR FOR DEVICES REQUIRING SUPPORT. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR REGARDING ELECTRICAL ROUGH-INS NECESSARY TO POWER ALL SECURITY SYSTEMS AND DEVICES. • ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 N.E.C. AND ASHREA 90.1 2007 ADDITIONAL ELECTRICAL REQUIREMENTS: 1. NFPA 99 COMPLIANCE FOR ADDITIONAL GROUNDING AND CHASSIS GROUNDING: 2. HFC MC CABLE TO BE USED: 3. HCF MCAP Type MC Cable - "All Purpose" is suitable for use as follows: 4. Branch-circuit wiring for general purpose in patient care areas of hospitals, medical and other health care facilities. Such areas include nursing homes, dental offices, and outpatient facilites. 5. Use in hazardous anesthetizing areas and essential electrical system circuits are prohibited, except where permitted per 2008 NEC® 517.30(C)(3)(3). 6. Applications requiring redundant, dedicated or isolated grounding paths. 7. Environmental air-handling spaces per NEC® 300.22(C); Dry locations; fished or embedded in plaster. 8. Places of Assembly per NEC® 518.4 and theaters per NEC® 520.5. Installation in cable tray and approved raceways. 9. Under raised floors for information technology equipment conductors and cables per NEC® 645.5(D) & 645.5(D)(2). 10. Multiple neutral and multi-circuit cables totaling more than 4 current-carrying conductors are now possible. TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 1/16/2018 9:50:36 AM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP E101 ELECTRICAL & SYSTEMS PLAN 17124 01.12.2018 90% CD'S/PRICING PLANS 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 Author 30102 1/4" = 1'-0" ? 1 ELECTRICAL PLAN ATC ELECTRIC P.O. BOX 205 Pittsboro, IN. 46167 100% CD'S