Loading...
HomeMy WebLinkAboutG001 LIFESAFETY PLANCOPIER REF. 1HR RATED WALL 104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE 117 159 SF BREAK ROOM 116 413 SF CORRIDOR 121 1HR RATED WALL 52' - 2" 47' - 0" EXIT EXIT EXIT 48' - 4" 1-HR RATED ELEVATOR SHAFT 1-HR RATED WALL ELEV. ELEV. STAIR MEN'S PUBLIC RESTROOM WOMEN'S PUBLIC RESTROOM 1-HR RATED WALL 2-HR RATED WALL 2-HR RATED WALL WON DOOR SYMBOL / LINETYPE DESCRIPTION 1 HR FIRE BARRIER 2 HR SMOKE/FIRE BARRIER SMOKE RESISTANT CORRIDOR SUITE OF ROOMS NON-RATED INCIDENTAL USE SEPARATION LIFE SAFETY PLAN LEGEND NOTE: Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling as follows: 1. Locate above suspended lay-in panel ceilings and in accessible attic spaces. 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the wording: "FIRE WALL or FIRE BARRIER – PROTECT ALL OPENINGS". PROJECT LIMITS CODE SUMMARY Indiana Building Codes (IBC 2014): 2012 IBC w/ Amendments (Building Code) 2012 IFC w/ Amendments (Fire Code) 2012 IMC w/ Amendments (Mechanical Code) 2006 IPC w/ Amendments (Plumbing Code) 2008 NFPA 70 w/ Amendments (Electrical Code) 2012 IBC Chapter 11 w/ Amendments & 2009 ANSI A117.1 (Handicapped Accessibility Code) 2007 ASHRAE 90.1 w/ Amendments (Energy Code) 2012 IFGC w/ Amendments (Fuel Gas Code) Federal: 2000 NFPA 101, Life Safety Code (LSC) 2012 ADA Standards for Accessible Design Code references are from the 2014 IBC unless otherwise noted - where the IBC and LSC address the same topic, the most strict provision is noted. Applicable Codes: Construction 2,881 SQ. FT. Area: B - Business - Doctor's Offices [Sec. 308.4, IBC] Occupancy Classificatio n: Renovation of existing doctor's offices into a new plastics doctor's office. No change in occupancy or construction type is anticipated. Project Description: Fully Covered Existing Sprinkler System: None in construction area. Existing Smoke Detector System: Smoke detectors present in corridors and fire srobes in all existing spaces. Fire Alarm System: Construction Type: 42,800 SQ. FT., 4 STORIES Building Area: ll-B arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:50:04 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP G001 LIFE SAFETY PLAN 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL/NJA 30102 1/8" = 1'-0" ? 1 LIFE SAFETY PLAN - 1ST FLOOR EXIT