HomeMy WebLinkAboutG001 LIFESAFETY PLANCOPIER
REF.
1HR RATED WALL
104 SF
EXAM 1
103
104 SF
EXAM 2
104 143 SF
TREATMENT
120
66 SF
STORAGE
119
92 SF
OFFICE
118
457 SF
WAITING
100
156 SF
ESTHETICIAN
109
232 SF
FRONT OFFICE
101
44 SF
CLEAN LINEN
107
40 SF
TLT- PATIENT
108
11 SF
SOILED
113
128 SF
OFFICE/ CONSULT
110
12 SF
BIO
112
48 SF
CHECK OUT
102
79 SF
CORR.
114
104 SF
EXAM 3
105
20 SF
STORAGE
111
175 SF
MA STATION
106
79 SF
OFFICE
117
159 SF
BREAK ROOM
116
413 SF
CORRIDOR
121 1HR RATED WALL
52' - 2"
47' - 0"
EXIT
EXIT
EXIT
48' - 4"
1-HR RATED
ELEVATOR
SHAFT
1-HR RATED
WALL
ELEV.
ELEV.
STAIR
MEN'S
PUBLIC
RESTROOM
WOMEN'S
PUBLIC
RESTROOM
1-HR RATED
WALL
2-HR RATED
WALL
2-HR RATED
WALL
WON DOOR
SYMBOL / LINETYPE DESCRIPTION
1 HR FIRE BARRIER
2 HR SMOKE/FIRE BARRIER
SMOKE RESISTANT CORRIDOR
SUITE OF ROOMS
NON-RATED INCIDENTAL USE SEPARATION
LIFE SAFETY PLAN LEGEND
NOTE: Fire walls and vertical fire barriers shall be effectively and permanently
identified with signs or stenciling as follows:
1. Locate above suspended lay-in panel ceilings and in accessible attic
spaces.
2. Be located within 15 feet of the end of each wall and at intervals not
exceeding 30 feet measured horizontally along the wall or partition; and
3. Include lettering not less than 3 inches in height with a minimum 3/8 inch
stroke in a contrasting color incorporating the wording:
"FIRE WALL or FIRE BARRIER – PROTECT ALL OPENINGS".
PROJECT LIMITS
CODE SUMMARY
Indiana Building Codes (IBC 2014):
2012 IBC w/ Amendments (Building Code)
2012 IFC w/ Amendments (Fire Code)
2012 IMC w/ Amendments (Mechanical Code)
2006 IPC w/ Amendments (Plumbing Code)
2008 NFPA 70 w/ Amendments (Electrical Code)
2012 IBC Chapter 11 w/ Amendments & 2009 ANSI
A117.1 (Handicapped
Accessibility Code)
2007 ASHRAE 90.1 w/ Amendments (Energy Code)
2012 IFGC w/ Amendments (Fuel Gas Code)
Federal:
2000 NFPA 101, Life Safety Code (LSC)
2012 ADA Standards for Accessible Design
Code references are from the 2014 IBC unless otherwise noted -
where the IBC and LSC address the same topic, the most strict
provision is noted.
Applicable Codes:
Construction 2,881 SQ. FT.
Area:
B - Business - Doctor's Offices [Sec. 308.4, IBC]
Occupancy
Classificatio
n:
Renovation of existing doctor's offices into a new plastics
doctor's office. No change in occupancy or construction type is
anticipated.
Project
Description:
Fully Covered
Existing Sprinkler
System:
None in construction area.
Existing Smoke
Detector System:
Smoke detectors present in corridors and fire srobes in all
existing spaces.
Fire Alarm System:
Construction Type:
42,800 SQ. FT., 4
STORIES
Building
Area:
ll-B
arcDESIGN Project Number:
Date:
Drawing Title:
Drawing Number:
Revisions:
Drawn By:
Client Project Number:
201 N. Delaware Street, Suite B
Indianapolis, IN 46204
317.951.9192 T | 317.951.9194 F
www.arcdesign.us
This drawing and its contents are the property
of arcDESIGN P.C., and shall not be
reproduced in whole or in part by any means,
mechanical or electronic, without express
written permission of arcDESIGN.
2/20/2018 12:50:04 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt
ST. VINCENT MEDICAL GROUP
G001
LIFE SAFETY
PLAN
17124
02.20.2018
100% CD'S
30102 - CARMEL PLASTIC SURGERY
13450 N. MERIDIAN, SUITE 140
CARMEL, IN 46032
JBL/NJA
30102
1/8" = 1'-0" ?
1 LIFE SAFETY PLAN - 1ST FLOOR
EXIT