Loading...
HomeMy WebLinkAbout20180220 Carmel Plastic SurgeryarcDESIGN, PC 201 N. Delaware St. Indianapolis, IN 46204 Telephone: 317.951.9192 Fax: 317.951.9194 www.arcdesign.us ARCHITECT Location Map Vicinity Map arcDESIGN Project Number: Date: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. Drawing Number: PROJECT MANAGEMENT Medxcel Facilities Management 7702 Woodland Drive Suite 200 Indianapolis, IN 46278 317.338.3053 www.medxcelfm.com GENERAL CONTRACTOR FURNITURE VENDOR Officeworks 12000 Exit Five Parkway Fishers, IN 46037 317.577.3531 www.officeworks.net Summit Construction 1107 Burdsal Parkway Indianapolis, IN 46208 317.634.6112 2/20/2018 12:50:03 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 100% CD'S - 02.20.2018 ST. VINCENT MEDICAL GROUP 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 30102 G000 DRAWING LIST 00 General G001 LIFE SAFETY PLAN 03 Architectural A001 ARCHITECTURAL GENERAL NOTES A002 TYPES COPIER REF. 1HR RATED WALL 104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE 117 159 SF GENERAL FLOOR PLAN NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM ITS RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH ALL OTHER SUBCONTRACTORS AND TRADES, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THESE DOCUMENTS, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS CONTAINED THEREIN. B. THE CONTRACTOR AND ALL ITS SUBCONTRACTORS SHALL VERIFY IN THE FIELD ALL NEW AND EXISTING APPLICABLE CONDITIONS, DIMENSIONS, RELATIONSHIPS, ETC. SHOWN IN THESE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY, ITS FAILURE TO COMPLY WITH THIS REQUIREMENT. C. ALL FLOOR PLAN DIMENSIONS SHOWN ON THE NEW FLOOR PLANS ARE FROM FACE OF FINISHED WALL (WHETHER NEW OR EXISTING WALL) UNLESS INDICATED OTHERWISE BY THE DESIGNATIONS "CLR", "CLEAR", OR "MIN." COORDINATE WITH APPLICABLE NEW WALL TYPES AND WITH APPLICABLE SECTIONS/DETAILS. D. ALL NEW HOLLOW METAL (HM). DOOR FRAMES ARE LOCATED 4" FROM THE ADJACENT WALL FACE (TO OUTER EDGE OF FRAME) UNLESS DIMENSIONED OR DETAILED OTHERWISE. E. COORDINATE, PROVIDE, AND INSTALL 2X FIRE TREATED WOOD WALL BLOCKING AS REQUIRED FOR THE ANCHORAGE AND SUPPORT OF ALL NEW CASEWORK, TRIM, FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, MARKER BOARDS, TACK BOARDS, DOOR HARDWARE ACCESSORIES, ETC., AS APPLICABLE. F. ALL NEW OR EXISTING FLOOR AREAS THAT REQUIRE LEVELING WITH A CONCRETE TOPPING OR LEVELING COMPOUND SHALL BE INSTALLED SUCH THAT THE FLATNESS EQUALS 35/24 (ON ALL SLABS) AND THE LEVELNESS EQUALS (SLAB ON GRADE) AND 80% OF THAT VALUE ON ELEVATED SLABS. G. AT ALL AREAS WHERE EXISTING FLOOR COVERING OR WALL COVERING MATERIAL WAS REMOVED, THE CONTRACTOR SHALL PROPERLY PREPARE THE SURFACE TO RECEIVE NEW FINISHES. H. CONTRACTOR SHALL ENSURE THAT ANY AND ALL BACKBOXES LOCATED WITHIN 'PARTY WALLS' THAT SEPARATE ROOMS ARE NOT LOCATED BACK TO BACK OR IN THE SAME CAVITY. STAGGER BOXES ONE STUD CAVITY EITHER SIDE OF ONE ANOTHER. I. PATCH ALL EXISTING WALLS AT LOCATIONS OF NEW OR REMOVED MEP WORK. GENERAL CEILING PLAN NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ACOUSTIC PANEL CEILING SYSTEMS ARE CENTERED IN ROOMS UNLESS NOTED OTHERWISE. B. COMPLY WITH ASTM C 636, ASTM E 580, AND SEISMIC DESIGN REQUIREMENTS INDICATED, PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND CISCA'S "CEILING SYSTEMS HANDBOOK." C. MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL PANELS TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING. AVOID USING LESS-THAN-HALF-WIDTH SQUARE-EDGE VINYL-FACED ACOUSTICAL CEILING PANELS. 15/16" ACOUSTICAL PANEL CEILING SUSPENSION GRID (WHITE). ACOUSTICAL PANEL CEILING SUSPENSION WIRE. DO NOT ATTACH TO DECK. APC-1 2x2 Grid System 5/8" GB TYPICAL 3 5/8" 20 GA. METAL STUD FRAMING @ 16" O.C. CORNER BEAD FINISH, TYPICAL 5/8" GB. TO RECEIVE (P1) CEILING ELEVATION CALLOUTS ARE TO THE GB-1 BOTTOM OF GB KICKER BRACING TO STRUCTURE ABOVE AT 48" O.C. MAX. A P C - CEILING TYPE GB = GYPSUM BOARD APC = ACOUSTICAL PANEL CEILING DPC = DECORATIVE PANEL CEILING DCG= DECORATIVE CEILING GRID CEILING TYPE MODIFIER SEE DRAWINGS CEILING NAMING CONVENTION 1 S 4. 1 A SUBSTRATE / FRAME / BACKUP S = STEEL STUD W = WOOD STUD M = MASONRY (CMU) F = FURRING (STEEL U.N.O.) I = METAL-FACED RIGID INSULATION H = SHAFT WALL (STEEL U.N.O.) NOMINAL SUBSTRATE WIDTH (REFER TO WALL TYPE FOR SUBSTRATE WIDTH) WALL EXTENTS MODIFIER (OPTIONAL) (REFER TO WALL TYPES FOR ADDITIONAL INFORMATION) WALL CHARACTERISTIC MODIFIER (OPTIONAL) a = 1 HR FIRE b = 2 HR FIRE c = 3 HR FIRE d = 4 HR FIRE s = SMOKE RESISTIVE i = INSULATIVE PLUMBING & ACCESSORIES PAPER TOWEL DISPENSER 2' - 10" REFLECT. SURF. 3' - 4" TO BOT. 3' - 5" 2" 2" MIRROR SOAP DISPENSER TYP. RIGHT OF SINK INSULATED PIPE WRAP LAVATORY, MIRROR & ACCESSORIES PAPER TOWEL DISPENSER 2' - 10" 3' - 4" 3' - 5" 2" MIRROR INSULATED PIPE WRAP LAVATORY, MIRROR, & ACCESSORIES ADJACENT TO WALL - FRONT VIEW 1' - 3" MIN IF ADJACENT TO WALL U.N.O. SOAP DISPENSER (ON SIDE WALL) LAVATORY, MIRROR, & ACCESSORIES ADJACENT TO WALL - SIDE VIEW 2' - 10" 3' - 5" 1' - 0" MIRROR PAPER TOWEL DISPENSER INSULATED PIPE WRAP SOAP DISPENSER PAPER TOWEL DISPENSER 2' - 10" 3' - 5" SOAP DISPENSER TYP. RIGHT OF SINK INSULATED PIPE WRAP LAVATORY & ACCESSORIES 1' - 3" MIN IF ADJACENT TO WALL U.N.O. PAPER TOWEL DISPENSER SOAP DISPENSER TYP. RIGHT OF SINK INSULATED PIPE WRAP COUNTERTOP SINK DEMOLITION LEGEND EXISTING WALL TO BE TO BE REMOVED COMPETE, INCLUDING ALL WALL PROTECTION, ELECTRICAL, DATA, NURSE CALL, AND SECURITY DEVICES. REFER TO MEP DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING WALL TO REMAIN KEYED NOTE BY ROOM KEYED NOTES BY OBJECT 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 3 4 4 2 2 2 2 2 2 2 2 2 5 2 2 2 2 6 6 7 7 6 7 6 7 6 7 6 7 6 7 7 6 7 6 7 REF. F.E.C. REF. F.E.C. 104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE REF. F.E.C. 104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE 117 159 SF BREAK ROOM EXAM 1 103 EXAM 2 104 TREATMENT 120 STORAGE 119 OFFICE 118 WAITING 100 ESTHETICIAN 109 FRONT OFFICE 101 CLEAN LINEN 107 TLT- PATIENT 108 SOILED 113 OFFICE/ CONSULT 110 BIO 112 CHECK OUT 102 CORR. 114 EXAM 3 105 STORAGE 111 MA STATION 106 OFFICE 117 BREAK ROOM 116 CORRIDOR 121 8' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 413 414 2' - 6" 2' - 0" 2' - 6" 4 6 5 2 2' - 6" 1' - 0" 1' - 0" 2' - 6" 9' - 0" OPEN BEOND 6 3 6 6 4 2 2' - 6" 2' - 0" 2' - 6" 413 2 4 6 6 6 6 414 OPEN BEYOND 2' - 6" 6" 4' - 0" 2' - 0" 4 5 6 3 6 5' - 0" 109 109 4' - 0" 3' - 6" 4' - 6" 1' - 0" 9' - 0" OPEN BEOND 2 3 OPEN BEYOND 3' - 0" 4' - 0" 2' - 0" 3 MAX. 2' - 10" 405 404 100 101 7 4' - 0" 6' - 0" 1 105 106 101 100 MAX. 2' - 10" 7 RESILIENT WALL BASE 5/8" GYPSUM WALL BOARD METAL SUPPORT BRACKET(S) AT 36" O.C. MAX. 1 1/2" PLASTIC LAMINATE WORKSURFACE. BACK EXAM 1 103 RB1 RS1 PT1 EXAM 2 104 RB1 RS1 PT1 TREATMENT 120 RB1 RS1 PT1 STORAGE 119 RB1 RS2 PT1 OFFICE 118 RB1 CPT1 PT1 WAITING 100 RB1 RS1 PT1 ESTHETICIAN 109 RB1 RS1 PT1 FRONT OFFICE 101 RB1 CPT1 PT1 CLEAN LINEN 107 RB1 RS2 PT1 TLT- PATIENT 108 EXIST. EXIST EXIST. SOILED 113 RB1 RS2 PT1 OFFICE/ CONSULT 110 RB1 CPT1 PT1 * 2" 2" * 2" 3 A601 4 A601 S1 * 2" 2" * 2" * 2" S2 * 6 A601 5 A601 * = REFER TO DOOR SCHEDULE REUSE DECORATIVE GLASS PANELS * * A * = REFER TO DOOR SCHEDULE SOUND BATTS. REFER TO WALL TYPES AND LEGEND METAL STUD FRAMING. REFER TO WALL TYPES AND LEGEND SEALANT BEAD AROUND ENTIRE PERIMETER. TYPICAL BOTH SIDES OF FRAME METAL STUD BOX HEADER HOLLOW METAL DOOR FRAME. PAINT SOUND BATTS. REFER TO WALL TYPES AND LEGEND METAL STUD FRAMING. REFER TO WALL TYPES AND LEGEND SEALANT BEAD AROUND ENTIRE PERIMETER. TYPICAL BOTH SIDES OF FRAME HOLLOW METAL DOOR FRAME. PAINT DOUBLE JAMB STUDS. REFER TO SPECIFICATIONS 2" 4" GLAZING, REUSE EXISTING DECORATIVE GLAZING. APPLIED METAL STOP. PAINT SOUND BATTS. REFER TO WALL TYPES AND LEGEND 104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE 117 159 SF BREAK ROOM 116 413 SF EXAM 1 103 EXAM 2 104 TREATMENT 120 STORAGE 119 OFFICE 118 WAITING 100 ESTHETICIAN 109 FRONT OFFICE 101 CLEAN LINEN 107 TLT- PATIENT 108 SOILED 113 OFFICE/ CONSULT 110 BIO 112 CHECK OUT 102 CORR. 114 EXAM 3 105 STORAGE 111 MA STATION 106 OFFICE 117 BREAK ROOM 116 CORRIDOR 121 8' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 9' - 0" APC-1 3' - 0" GENERAL NOTES SCOPE DOCUMENTS 1/8" = 1'-0" HVAC PLAN MP101 1/8"=1'-0" HVAC/PLUMBING PLANS 2/19/18 DMP JDS 18203 HVAC/PLUMBING PLUMBING PLAN 1/8" = 1'-0" LEGEND SPECIAL PLUMBING NOTES SPECIAL HVAC NOTES N.T.S. SINK PLUMBING ISOMETRIC W&V N.T.S. SINK PLUMBING ISOMETRIC WATER EXAM 1 103 EXAM 2 104 TREATMENT 120 STORAGE 119 OFFICE 118 WAITING 100 ESTHETICIAN 109 FRONT OFFICE 101 CLEAN LINEN 107 TLT- PATIENT 108 SOILED 113 OFFICE/ CONSULT 110 BIO 112 CHECK OUT 102 CORR. 114 EXAM 3 105 STORAGE 111 MA STATION 106 OFFICE 117 BREAK ROOM 116 CORRIDOR 121 3' - 0" STAIR EXIST. EQ EQ EQ EQ SHEET NO. CERTIFIED BY: NORTH: DATE DRAWN BY CHECKED BY JOB NO. PROPOSED INTERIORS FOR: ST. VINCENTS MEDICAL GROUP SCALE /%5 %QPVTCEVKPI 5VQP[%TGGM9C[ 0QDNGUXKNNG+PFKCPC ÄÄ 5GTXKEGU+PE /GEJCPKECN 13450 NORTH MERIDIAN ST. 140 CARMEL, INDIANA 46032 REV DATE DESCRIPTION TITLE CARMEL PLASTIC SURGERY F.E.C. CONNECT NEW DRAIN LINES INTO EXISTING DRAIN LINES. FIELD VERIFY EXISTING SANITARY LINE LOCATION PRIOR TO STARTING TRENCHING FOR NEW FIXTURES. NOTE: CONSTRUCTION AREA IS SLAB ON GRADE CONSTRUCTION. SAW CUT SLAB AND TRENCH AS REQUIRED FOR NEW WORK. INFILL WITH CONCRETE TO MATCH EXISTING EXAM 1 103 EXAM 2 104 TREATMENT 120 STORAGE 119 OFFICE 118 WAITING 100 ESTHETICIAN 109 FRONT OFFICE 101 CLEAN LINEN 107 TLT- PATIENT 108 SOILED 113 OFFICE/ CONSULT 110 BIO 112 CHECK OUT 102 CORR. 114 EXAM 3 105 STORAGE 111 MA STATION 106 OFFICE 117 BREAK ROOM 116 CORRIDOR 121 STAIR EXIST. WATER LINE SUPPLY TIE IN TO FOR NEW 8' - 0" GB-1 9' - 0" APC-1 1 1 1 1 1 1 1 1 1 1 2 3 3 3 3 3 NOT IN SCOPE 4 STAIR 4 4 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 EXIST. EQ EQ EQ EQ DESIGN BUILD ELECTRICAL NOTES • • • • • • • • ‡ • • • • • GENERAL SCOPE: THE HVAC, ELECTICAL/VOICE/DATA AND PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATED OTHERWISE. DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. CONTRACTORS SHALL FURNISH AND INSTALL ALL NECESSARY WORK AND COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. CONTRACTORS TO SUBMIT ALL FINAL HVAC DRAWINGS TO LANDLORD AND OWNER FOR REVIEW AND MUST RECEIVE FINAL APPROVAL FROM BOTH PARTIES PRIOR TO CONSTRUCTION. DESIGN/BUILD SUBCONTRACTORS SHALL REVIEW BUILDING SYSTEM SCOPE DOCUMENTS AND OFFER ANY MODIFICATIONS THAT MAY BE APPROPRIATE FOR COMPLETE AND OPERABLE SYSTEMS. ELECTRICAL SYSTEMS: THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THE AUDIO/VISUAL SYSTEMS, SECURITY SYSTEMS, AND IT SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS AND CIRCUITS. THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR DEVICE MOUNTING HEIGHTS. PROVIDE AND INSTALL ROUGH-INS AS REQUIRED FOR AUDIO/VISUAL, SECURITY SYSTEMS, AND IT SYSTEMS. AUDIO VISUAL SYSTEMS: THE PROJECT MANAGER IS TO PROVIDE AND COORDINATE ALL AV VENDORS WITH THE GENERAL CONTRACTOR FOR ALL AUDIO VISUAL, SECURITY ITEMS, INCLUDING, BUT NOT LIMITED TO: TELEVISION JACKS, SPEAKERS, AUDIO SOURCES, NURSE CALL DEVICES, AND ELECTRIC DOOR HARDWARE. THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL ITEMS. ALL SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR FOR ELECTRICAL ROUGH-INS NECESSARY TO POWER AUDIO VISUAL SYSTEMS DEVICES. SECURITY SYSTEMS: THE SECURITY SYSTEM CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL FIRE ALARM DEVICES, SECURITY DEVICES, SMOKE DETECTORS, CARD READERS AND FIRE SUPRESSION SYSTEMS. SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE BLOCKING WITH THE GENERAL CONTRACTOR FOR DEVICES REQUIRING SUPPORT. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR REGARDING ELECTRICAL ROUGH-INS NECESSARY TO POWER ALL SECURITY SYSTEMS AND DEVICES. • ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 N.E.C. AND ASHREA 90.1 2007 ADDITIONAL ELECTRICAL REQUIREMENTS: 1. NFPA 99 COMPLIANCE FOR ADDITIONAL GROUNDING AND CHASSIS GROUNDING: 2. HFC MC CABLE TO BE USED: 3. HCF MCAP Type MC Cable - "All Purpose" is suitable for use as follows: 4. Branch-circuit wiring for general purpose in patient care areas of hospitals, medical and other health care facilities. Such areas include nursing homes, dental offices, and outpatient facilites. 5. Use in hazardous anesthetizing areas and essential electrical system circuits are prohibited, except where permitted per 2008 NEC® 517.30(C)(3)(3). 6. Applications requiring redundant, dedicated or isolated grounding paths. 7. Environmental air-handling spaces per NEC® 300.22(C); Dry locations; fished or embedded in plaster. 8. Places of Assembly per NEC® 518.4 and theaters per NEC® 520.5. Installation in cable tray and approved raceways. 9. Under raised floors for information technology equipment conductors and cables per NEC® 645.5(D) & 645.5(D)(2). 10. Multiple neutral and multi-circuit cables totaling more than 4 current-carrying conductors are now possible. NEW GYP BOARD CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION NEW APC CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION NEW LIGHTING SWITCH: X - NUMBER OF POLES SCHEMATIC WIRE EXHAUST DIFFUSER - MATCH BUILDING STANDARD CEILING SYMBOLS x RETURN DIFFUSER - MATCH BUILDING STANDARD NEW SUPPLY DIFFUSER - MATCH BUILDING STANDARD NEW LIGHT FIXTURE: - 6" RECESSED LED CAN LIGHT #RL38 CAN / LED DK6 11W940 DIM G7 LED MODULE. 11 WATTS. NEW LIGHT FIXTURE - OCCUPANCY SENSOR INTEGRATED - 2' WIDE WALL MOUNT LIGHT FIXTURE #BLCSLED2FT 20 4K MV ET / OCS / 20 WATTS 2' NEW LIGHT FIXTURE - 2'x4' LAY-IN INDIRECT LED / 39 WATTS #BCBLED24-40W-4K MV PRM BES NEW LIGHT FIXTURE - 2'x4' LAY-IN TROFFER #LEDPNL2X4-35W-4K / 2X4 PANEL / 36 WATTS NEW EXIT SIGN FIXTURE - CEILING MOUNT LED EXIT SIGN #CBRCOMBO / 4W LED EXIT WITH TWIN EM HEADS. EXISTING APC CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION EXISTING GYP BOARD CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 1/16/2018 9:48:59 AM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP E102 REFLECTED CEILING PLAN 17124 01.12.2018 90% CD'S/PRICING PLANS 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 1/4" = 1'-0" ? 1 REFLECTED CEILING PLAN REFLECTED CEILING PLAN NOTES 1 MECHANICAL AND LIGHT FIXTURES TO REMAIN AS IS UNLESS NOTED OTHERWISE. 2 CEILING MOUNTED EXAM LIGHT PROVIDED BY TENANT, INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND INSTALL UNISTRUT CEILING MOUNTED LIGHT SUPPORT. CONTRACTOR TO PROVIDE 120V DEDICATED CIRCUIT FOR FIXTURE. 3 TIE EXTENDED BULKHEAD INTO EXISTING BULKHEAD. MATCH HEIGHT, RADIAL CURVATURE, AND TYPE OF EXISTING, ADJACENT CEILING TYPE. 4 LIGHT TO BE ON OCCUPANCY SENSOR. 5 ROOM TO RECEIVE 24-7 EXHAUST FAN. 6 INSTALL SALVAGED LIGHT FIXTURE IN ROOM. ATC ELECTRIC P.O. BOX 205 Pittsboro, IN. 46167 100% CD'S CORRIDOR 121 N +44, GFI +44, GFI +72" N N N N N N N N N N N N N N N N N N N N N N N N N N N N N +44, GFI +44, GFI N N N N NOT IN SCOPE STAIR TV +72" N N N N N N N N N N N N N N N N N N N N N N N N, D Xref S:\Operations\Active Projects\17124 Xref - St. S:V \Operations\- Dr. Paul Plastics\Active Projects\1 BIM\1.5 17124 Transfers\- St. V 20180116 - Dr. Paul - Plastics\Dr-Paul Plastic 1 BIM\1.Surgery-5 Transfers\Suite 20180116 140 E101- - Dr-ELECTRICAL Paul Plastic Surgery-& SYSTEMS Suite PLAN-140 - E101- Legend ELECTRICAL - DESIGN BUILD & SYSTEMS NOTES.PLAN-dwg Legend - DESIGN BUILD NOTES.dwg DEDICATED DUPLEX FOR FRIDGE. DEDICATED DUPLEX FOR MICROWAVE ABOVE SWITCH AND RECEPTACLE FOR DISPOSAL. GFI H H H H H N N N N N N N N N N N,D N N GFI +44 H N N N D D D H N N H N N H N N TV GFI POWER/DATA LEGEND SYMBOL NAME RESPONSIBILITY ELECTRICAL POWER PANEL ELECTRICAL TELEVISION JACK CONTRACTOR DUPLEX OUTLET ELECTRICAL DUPLEX OUTLET - GFI ELECTRICAL DATA OUTLET AHIS D DUPLEX OUTLET - DEDICATED ELECTRICAL EXIT EMERGENCY EXIT SIGN ELECTRICAL QUAD OUTLET ELECTRICAL V WALL MOUNTED VISUAL ALARM DEVICE ELECTRICAL DESIGN BUILD ELECTRICAL NOTES • • • • • • • • ‡ • • • • • GENERAL SCOPE: THE HVAC, ELECTICAL/VOICE/DATA AND PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATED OTHERWISE. DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. CONTRACTORS SHALL FURNISH AND INSTALL ALL NECESSARY WORK AND COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. CONTRACTORS TO SUBMIT ALL FINAL HVAC DRAWINGS TO LANDLORD AND OWNER FOR REVIEW AND MUST RECEIVE FINAL APPROVAL FROM BOTH PARTIES PRIOR TO CONSTRUCTION. DESIGN/BUILD SUBCONTRACTORS SHALL REVIEW BUILDING SYSTEM SCOPE DOCUMENTS AND OFFER ANY MODIFICATIONS THAT MAY BE APPROPRIATE FOR COMPLETE AND OPERABLE SYSTEMS. ELECTRICAL SYSTEMS: THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THE AUDIO/VISUAL SYSTEMS, SECURITY SYSTEMS, AND IT SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS AND CIRCUITS. THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR DEVICE MOUNTING HEIGHTS. PROVIDE AND INSTALL ROUGH-INS AS REQUIRED FOR AUDIO/VISUAL, SECURITY SYSTEMS, AND IT SYSTEMS. AUDIO VISUAL SYSTEMS: THE PROJECT MANAGER IS TO PROVIDE AND COORDINATE ALL AV VENDORS WITH THE GENERAL CONTRACTOR FOR ALL AUDIO VISUAL, SECURITY ITEMS, INCLUDING, BUT NOT LIMITED TO: TELEVISION JACKS, SPEAKERS, AUDIO SOURCES, NURSE CALL DEVICES, AND ELECTRIC DOOR HARDWARE. THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL ITEMS. ALL SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR FOR ELECTRICAL ROUGH-INS NECESSARY TO POWER AUDIO VISUAL SYSTEMS DEVICES. SECURITY SYSTEMS: THE SECURITY SYSTEM CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL FIRE ALARM DEVICES, SECURITY DEVICES, SMOKE DETECTORS, CARD READERS AND FIRE SUPRESSION SYSTEMS. SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE BLOCKING WITH THE GENERAL CONTRACTOR FOR DEVICES REQUIRING SUPPORT. THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR REGARDING ELECTRICAL ROUGH-INS NECESSARY TO POWER ALL SECURITY SYSTEMS AND DEVICES. • ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 N.E.C. AND ASHREA 90.1 2007 ADDITIONAL ELECTRICAL REQUIREMENTS: 1. NFPA 99 COMPLIANCE FOR ADDITIONAL GROUNDING AND CHASSIS GROUNDING: 2. HFC MC CABLE TO BE USED: 3. HCF MCAP Type MC Cable - "All Purpose" is suitable for use as follows: 4. Branch-circuit wiring for general purpose in patient care areas of hospitals, medical and other health care facilities. Such areas include nursing homes, dental offices, and outpatient facilites. 5. Use in hazardous anesthetizing areas and essential electrical system circuits are prohibited, except where permitted per 2008 NEC® 517.30(C)(3)(3). 6. Applications requiring redundant, dedicated or isolated grounding paths. 7. Environmental air-handling spaces per NEC® 300.22(C); Dry locations; fished or embedded in plaster. 8. Places of Assembly per NEC® 518.4 and theaters per NEC® 520.5. Installation in cable tray and approved raceways. 9. Under raised floors for information technology equipment conductors and cables per NEC® 645.5(D) & 645.5(D)(2). 10. Multiple neutral and multi-circuit cables totaling more than 4 current-carrying conductors are now possible. TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 1/16/2018 9:50:36 AM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP E101 ELECTRICAL & SYSTEMS PLAN 17124 01.12.2018 90% CD'S/PRICING PLANS 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 Author 30102 1/4" = 1'-0" ? 1 ELECTRICAL PLAN ATC ELECTRIC P.O. BOX 205 Pittsboro, IN. 46167 100% CD'S METAL STUD FRAMING. REFER TO WALL TYPES AND LEGEND SEALANT BEAD AROUND ENTIRE PERIMETER. TYPICAL BOTH SIDES OF FRAME HOLLOW METAL DOOR FRAME. PAINT METAL STUD BOX HEADER 2" GLAZING, REUSE EXISTING DECORATIVE GLAZING. APPLIED METAL STOP. PAINT SOUND BATTS. REFER TO WALL TYPES AND LEGEND METAL STUD FRAMING. REFER TO WALL TYPES AND LEGEND SEALANT BEAD AROUND ENTIRE PERIMETER. TYPICAL BOTH SIDES OF FRAME HOLLOW METAL DOOR FRAME. PAINT DOUBLE JAMB STUDS. REFER TO SPECIFICATIONS arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:50:03 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A601 OPENING TYPES AND SCHEDULES 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 DOOR SCHEDULE Mark Room Name Door Frame Hardware Width Height Material Elevation Material Elevation Door Lock Door Stop Remarks 100A WAITING 4' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. 100B WAITING 4' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. 101 FRONT OFFICE 3' - 0" 7' - 0" WOOD A KDHM S1 PS OH 103 EXAM 1 3' - 0" 7' - 0" WOOD A KDHM S1 PS OH PROVIDE MIRROR ON INTERIOR FACE OF DOOR. 104 EXAM 2 3' - 0" 7' - 0" WOOD A KDHM S1 PS OH PROVIDE MIRROR ON INTERIOR FACE OF DOOR. 105 EXAM 3 3' - 0" 7' - 0" WOOD A KDHM S1 PS OH PROVIDE MIRROR ON INTERIOR FACE OF DOOR. 106 MA STATION 3' - 6" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. 107 CLEAN LINEN 3' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. PROVIDE NEW CORE. 108 TLT-PATIENT 3' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. 109 AESTHETICIAN 4' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. 110 OFFICE/CONSULT 3' - 0" 7' - 0" WOOD A KDHM S2 OF WS PROVIDE COAT HOOK ON INTERIOR FACE OF DOOR. 111 STORAGE 3' - 0" 7' - 0" WOOD A KDHM S1 ST OH 112 BIO 2' - 6" 7' - 0" WOOD A KDHM S1 ST OH 113 SOILED 2' - 6" 7' - 0" WOOD A KDHM S1 ST OH 114 CORRIDOR 3' - 6" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. 116 BREAK ROOM 3' - 0" 7' - 0" WOOD A KDHM S1 PS WS 117 OFFICE 3' - 0" 7' - 0" WOOD A KDHM S2 OF WS PROVIDE COAT HOOK ON INTERIOR FACE OF DOOR. 118 OFFICE 3' - 0" 7' - 0" WOOD A KDHM S2 OF WS PROVIDE COAT HOOK ON INTERIOR FACE OF DOOR. 119 STORAGE 4' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. ST WS TOUCH UP DOOR AND FRAME. REPLACE DOOR HARDWARE. 120 TREATMENT 4' - 0" 7' - 0" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TOUCH UP DOOR AND FRAME. GENERAL NOTES: 1. ALL WOOD DOORS TO MATCH EXISTING. REUSE DOORS WHERE POSSIBLE PRIOR TO ORDERING NEW. 2. ALL DOOR HARDWARE FINISH TO MATCH BUILDING STANDARD. 3. ALL HARDWARE TO BE BUILDING STANDARD. DOOR OPERATION TO BE LEVER TYPE. 4. ALL LOCKSETS TO ACCEPT OWNER STANDARD CORE (BEST). 5. ALL HINGES TO BE (5) KNUCKLE HINGES. 6. ALL DOOR OPENINGS TO RECEIVE DOOR SILENCERS. 7. ALL EXISTING DOOR HARDWARE TO REMAIN AS IS UNLESS NOTED OTHERWISE. DOOR MATERIAL: EX - EXISTING GLASS - REFER TO REMARKS FOR GLASS TYPE WOOD - MARSHFIELD (REFER TO INTERIOR FINISH SELECTION FOR CUT AND FINISH) DOOR ELEVATION: A-Z - REFER TO DOOR ELEVATIONS EX - EXISTING DOOR FRAME MATERIALS: AL - ALUMINUM EX - EXISTING HM - HOLLOW METAL KDHM - KNOCK DOWN HOLLOW METAL (PRIMED) FRAME ELEVATION: A-Z - REFER TO FRAME ELEVATIONS EX - EXISTING CLOSERS: C - CLOSER - MATCH BUILDING STANDARD CS - CLOSER WITH STOP - MATCH BUILDING STANDARD LOCK: EN - ENTRANCE LOCKSET OF - OFFICE LOCKSET PS - PASSAGE LOCKSET PV - PRIVACY LOCKSET ST - STOREROOM LOCKSET TR - TRILOGY ELECTRIC KEYPAD LOCKSET (BY GC) DOOR STOP: OH - OVERHEAD STOP WS - WALL BUMPER STOP VOLTAGE: X DOOR REQUIRES POWER. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ELECTRICAL ROUGH-IN AS REQUIRED. COORDINATE NECESSARY POWER AND LOCATION WITH SECURITY SYSTEM CONTRACTOR AND AUDIO/VISUAL CONTRACTOR. DOOR NOTES 3/8" = 1'-0" ? 3/8" = 1'-0" ? 1 DOOR FRAME TYPES 3" = 1'-0" REFERENCE: 1 / A601 2 DOOR TYPES 3" = 1'-0" REFERENCE: 1 / A601 3 HEAD DETAIL 4 JAMB DETAIL 3" = 1'-0" REFERENCE: 1 / A601 3" = 1'-0" REFERENCE: 1 / A601 5 HEAD DETAIL 6 JAMB DETAIL BIO 112 RB1 RS2 PT1 CHECK OUT 102 RB1 RS1 PT1 CORR. 114 RB1 RS1 PT1 EXAM 3 105 RB1 RS1 PT1 STORAGE 111 RB1 RS2 PT1 MA STATION 106 RB1 RS1 PT1 OFFICE 117 RB1 CPT1 PT1 BREAK ROOM 116 RB1 RS1 PT1 CORRIDOR 121 RB1 RS1 PT1 PT2 PT2 PT2 NOT IN SCOPE STAIR PT2 PT2 PT2 PT2 PT2 PT2 PT2 PT2 PT2 PT2 PT2 PT2 NOT IN SCOPE STAIR PT2 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 INTERIOR FINISH NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ALL WALLS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE. B. PROCEEDING WITH THE INSTALLATION OF FINISHES WILL BE CONSTRUED THAT THE INSTALLER AND/OR FINISHER HAS INSPECTED AND ACCEPTED THE SUBSTRATE FOR RECEIVING THE WORK. NO CHANGE ORDER WILL BE ISSUED TO RECTIFY CONCEALED, UNKNOWN CONDITIONS OR UNSATISFACTORY SUBSTRATE ONCE THE FINISH WORK HAS PROCEEDED. C. CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER IF A SPECIFIED FINISH ITEM BECOMES UNAVAILABLE. D. PROVIDE FULL HEIGHT CORNER GUARDS (CG1) ON ALL EXPOSED CORNERS. SEE GENERAL MOUNTING HEIGHTS FOR DETAILS. E. PROVIDE NEW MINI-BLINDS ON ALL WINDOWS IN PROJECT SCOPE. MATCH BUILDING STANDARD. CONTRACTOR TO NOTIFY BUILDING OWNER IF EXISTING MINI-BLINDS ARE DAMAGED AND NEED TO BE REPLACED. F. ALL DOOR FRAMES AND FRAMED OPENINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE. G. REFER TO INSTALLATION DIRECTIONAL ARROW NOTED IN ALL ROOMS TO RECEIVE (RS1). arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:50:02 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A510 INTERIOR FINISH PLAN &DETAILS 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 1/4" = 1'-0" ? 1 INTERIOR FINISH PLAN INTERIOR FINISH SCHEDULE CARPET CPT1 MANUFACTURER: MANNINGTON STYLE: CROSSTOWN COLOR: METRO 14215 SIZE: 18"x36" INSTALL: ASHLAR RESILIENT FLOORING & WALL BASE RS1 MANUFACTURER: TANDUS CENTIVA STYLE: HERTIAGE PLANK #EHP COLOR: SMOKED OAK 3350 SIZE: 6"x36" RS2 MANUFACTURER: JOHNSITE STYLE: AZROCK VCT COLOR: V-234 PINCH OF SALT SIZE: 12"x12" RB1 MANUFACTURER: JOHNSONITE STYLE: 4” COVE BASE COLOR: MOONROCK29 LENGTH: CONTINUOUS COIL PAINT PT1 MANUFACTURER: PRATT & LAMBERT NUMBER: 11-32 NAME: “CHALK GRAY” FINISH: EGGSHELL LOCATION: FIELD COLOR PT2 MANUFACTURER: PRATT & LAMBERT NUMBER: 29-21 NAME: “DEPENDABLE” FINISH: EGGSHELL LOCATION: ACCENT WALL PT3 MANUFACTURER: PRATT & LAMBERT NUMBER: 11-32 NAME: “CHALK GRAY” FINISH: SEMI-GLOSS LOCATION: DOOR FRAMES ACOUSTIC LAY-IN CEILING APC-1 MANUFACTURER: MATCH BUILDING STANDARD STYLE: MATCH BUILDING STANDARD COLOR/TYPE: MATCH BUILDING STANDARD SIZE: 24”x24” GRID: MATCH BUILDING STANDARD PLASTIC LAMINATE PL1 MANUFACTURER: WILSONART COLOR: HARVEST MAPLE 7953 THICKNESS: 1-1/2” THICK PVC EDGE: PROVIDE 3MM PVC NOTES: EDGEBANDING TO MATCH PL2 MANUFACTURER: WILSONART COLOR: CLASSIC LINEN 4943 THICKNESS: 1-1/2” THICK PVC EDGE: PROVIDE 3MM PVC NOTES: EDGEBANDING TO MATCH WALL PROTECTION WP1 MANUFACTURER: INPRO COLOR: FEATHER 0238 TYPE/STYLE: RIGID SHEET VINYL CG1 MANUFACTURER: INPRO COLOR: FEATHER 0238 TYPE/STYLE: SURFACE MOUNT; 2” WING LENGTH: FULL-HEIGHT SPLASH WHERE INDICATED. REFER TO ELEVATIONS. BLOCKING BLOCKING REFER TO ELEVATION 2' - 1" 3MM PVC EDGE TO MATCH BEAD OF CLEAR SEALANT 1 1/2" PLASTIC LAMINATE COUNTERTOP SUBSTRATE AS PER PLASTIC LAMINATE MATERIAL MANUFACTURER REQUIEMENTS. T-MOLD 3mm PVC EDGEBANDING 4" 3/8" SEALANT PLASTIC LAMINATE BACKSPLASH 3/8" BACK SPLASH OPTIONAL SUBSTRATE AS RECOMMENDED BY MANUFACTURER SEALANT 3mm PVC EDGE, TYP. PLASTIC LAMINATE ON 3/4" SUBSTRATE BLOCKING METAL STUD RUNNER TRACK 5/8" GYP. BD. 3 5/8" MTL. STUDS FIRE RETARDANT WOOD BLOCKING METAL COUNTER SUPPORT BRACKET AT 36" O.C. MAX. FIRE RETARDANT WOOD BLOCKING PLASTIC LAMINATE ON SUBSTRATE WALL BASE, REFER TO INTERIOR FINISH DRAWINGS FINISHED FLOOR. 2' - 6" 1' - 0" 1 1/2" 1 1/2" * 4 7/8" * 3mm PVC EDGE, TYP. 3mm PVC EDGE, TYP. BEAD OF CLEAR SEALANT MOLDING END CLOSURE OF MULLION WINDOW MULLION SILL BELOW METAL STUD FRAMING. REFER TO WALL TYPES AND LEGEND. BEAD OF CLEAR SEALANT arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:50:00 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A301 INTERIOR ELEVATIONS & DETAILS 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 INTERIOR ELEVATION NOTES 1 NEW ADJUSTABLE SHELF STANDARDS AND BRACKETS WITH (4) WHITE MELAMINE ADJUSTABLE SHELVES. 2 CASEWORK PROVIDED BY OFFICEWORKS. CONTRACTOR TO WORK WITH VENDOR TO DETERMINE REQUIRED BLOCKING LOCATIONS. 3 11"D. x 1-1/2" THICK PLASTIC LAMINATE TRANSACTION TOP. (PL1) 4 25"D. x 1-1/2" THICK PLASTIC LAMINATE COUNTERTOP. (PL2) 5 PLASTIC LAMINATE FINISHED END PANEL. (PL1) 6 PROVIDE METAL COUNTERTOP SUPPORT BRACKET. SPACE BRACKETS AT 33" O.C. MIN. UNLESS NOTED OTHERWISE. 7 CASEWORK, SINK AND FAUCET PROVIDED BY OFFICEWORKS. CONTRACTOR TO COORDINATE PLUMBING WITH VENDOR. 3/8" = 1'-0" REFERENCE: 1 / A111 1 FRONT OFFICE 101 - NORTH 3/8" = 1'-0" REFERENCE: 1 / A111 6 FRONT OFFICE 101 - SOUTH 3/8" = 1'-0" REFERENCE: 1 / A111 3/8" = 1'-0" REFERENCE: 1 / A111 2 FRONT OFFICE 101 - WEST 4 FRONT OFFICE 101 - EAST 3/8" = 1'-0" REFERENCE: 1 / A111 5 WAITING 100 - NORTH 3/8" = 1'-0" REFERENCE: 1 / A111 3 CHECK OUT 102- WEST 3/8" = 1'-0" REFERENCE: 1 / A111 7 EXAM CASEWORK TYPICAL 3/8" = 1'-0" REFERENCE: 1 / A111 9 ADJUSTABLE SHELVING TYPICAL 3/8" = 1'-0" REFERENCE: 1 / A111 8 BREAK ROOM 116 - SOUTH 3/4" = 1'-0" ? PLASTIC LAMINATE COUNTERTOP 11 DETAIL 6" = 1'-0" ? 6" = 1'-0" ? 13 PLASTIC LAMINATE EDGE DETAIL PLASTIC LAMINATE BACKSPLASH 14 DETAIL 3/4" = 1'-0" ? 12 TRANSACTION DETAIL 3" = 1'-0" REFERENCE: 1 / A111 10 WALL TO MULLION DETAIL 3' - 0" 8' - 0" GB-1 9' - 0" APC-1 1 1 1 1 1 1 1 1 1 1 2 3 3 3 3 3 NOT IN SCOPE STAIR 4 4 4 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 EXIST. EQ EQ EQ EQ DESIGN BUILD HVAC, ELECTRICAL, PLUMBING NOTES GENERAL SCOPE: THE HVAC, ELECTICAL/VOICE/DATA AND PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATED OTHERWISE. DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. CONTRACTORS SHALL FURNISH AND INSTALL ALL NECESSARY WORK AND COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. CONTRACTORS TO SUBMIT ALL FINAL HVAC DRAWINGS TO LANDLORD AND OWNER FOR REVIEW AND MUST RECEIVE FINAL APPROVAL FROM BOTH PARTIES PRIOR TO CONSTRUCTION. DESIGN/BUILD SUBCONTRACTORS SHALL REVIEW BUILDING SYSTEM SCOPE DOCUMENTS AND OFFER ANY MODIFICATIONS THAT MAY BE APPROPRIATE FOR COMPLETE AND OPERABLE SYSTEMS. HVAC: • THE HVAC CONTRACTOR SHALL "BALANCE" THE SYSTEM PRIOR TO THE TENANT'S MOVE-IN DATE. • THE HVAC CONTRACTOR SHALL VERIFY WITH THE TENANT HOW THE SYSTEM IS TO BE "ZONED" AND IDENTIFY THE LOCATION OF ALL THERMOSTATS. • IN EXISTING SPACES BEING FULLY OR PARTIALLY DEMOLISHED, ALL HVAC SUPPLY AND RETURN DIFFUSERS SHALL BE NEW. • PROVIDE "SOUND BOOTS" IN ALL RETURN AIR GRILLES IN ALL AREAS. • ALL HVAC DIFFUSERS, THERMOSTATS, GRILLES, AND EXHAUST FANS TO MATCH BUILDING STANDARD. • REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR THERMOSTAT MOUNTING HEIGHTS. • THE HVAC CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR IN REGARDS TO ELECTRICAL ROUGH-IN NECESSARY TO POWER HVAC SYSTEMS OR DEVICES. ELECTRICAL SYSTEMS: • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THE AUDIO/VISUAL SYSTEMS, SECURITY SYSTEMS, AND IT SYSTEMS. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. • THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS AND CIRCUITS. • THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. • REFER TO TYPICAL MOUNTING HEIGHTS SHEET FOR DEVICE MOUNTING HEIGHTS. • PROVIDE AND INSTALL ROUGH-INS AS REQUIRED FOR AUDIO/VISUAL, SECURITY SYSTEMS, AND IT SYSTEMS. PLUMBING: • ALL NEW AND EXISTING HOT WATER LINES SHALL BE INSULATED. • ALL NEW AND EXISTING PVC OVERHEAD PIPING ABOVE THE CEILINGS SHALL BE WRAPPED WITH "FIRE TAPE". • ALL FIXTURES TO BE WHITE. ALL EXPOSED PIPING AND SUPPLY FITTINGS SHALL BE CHROMIUM PLATED. ALL PIPING WALL PENETRATIONS SHALL HAVE CHROMIUM PLATED ESCUTCHEONS. • ALL PIPING SHOWN ON PLUMBING DRAWINGS IS DIAGRAMATIC. FIELD VERIFY FOR EXACT ROUTING. • ACCESSIBLE PLUMBING FIXTURES SHALL COMPLY WITH ADA. • AFTER COMPLETION OF THE WATER SUPPLY SYSTEM ROUGH-IN AND BEFORE THE FIXTURES HAVE BEEN SET, THE ENTIRE COLD AND HOT WATER SUPPLY SYSTEM SHALL BE PRESSURE TESTED TO AT LEAST 100 PSI AND BE FREE OF LEAKS. • THE ENTIRE DOMESTIC WATER SUPPLY SYSTEM SHALL BE THOROUGHLY STERILIZED WITH A SOLUTION OF 50 PARTS PER MILLION CHLORINE IN ACCORDANCE WITH THE RECOMMENDATION OF THE MANUFACTURER FOR SUCH USE. • REFER TO TYPICAL MOUNTING SHEET FOR PLUMBING FIXTURE MOUNTING HEIGHTS. • PROVIDE AND INSTALL "HANDI-LAV-GUARD" INSULATION AT EACH LAVATORY - TRUEBRO INC. - WHITE (VERIFY MODEL NUMBER) • PROVIDE AND INSTALL SHUT-OFF-VALVES TO ISOLATE ALL PLUMBING WITHIN SUITE. AUDIO VISUAL SYSTEMS: • THE PROJECT MANAGER IS TO PROVIDE AND COORDINATE ALL AV VENDORS WITH THE GENERAL CONTRACTOR FOR ALL AUDIO VISUAL, SECURITY ITEMS, INCLUDING, BUT NOT LIMITED TO: TELEVISION JACKS, SPEAKERS, AUDIO SOURCES, NURSE CALL DEVICES, AND ELECTRIC DOOR HARDWARE. • THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL ITEMS. ALL SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. • THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. • THE AUDIO VISUAL CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR FOR ELECTRICAL ROUGH-INS NECESSARY TO POWER AUDIO VISUAL SYSTEMS DEVICES. SECURITY SYSTEMS: • THE SECURITY SYSTEM CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH A SET OF SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL FIRE ALARM DEVICES, SECURITY DEVICES, SMOKE DETECTORS, CARD READERS AND FIRE SUPRESSION SYSTEMS. SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO ANY CONSTRUCTION. • THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS IN REGARDS TO THEIR SYSTEMS AND DEVICES. • THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE BLOCKING WITH THE GENERAL CONTRACTOR FOR DEVICES REQUIRING SUPPORT. • THE SECURITY SYSTEM CONTRACTOR SHALL COORDINATE WITH THE ELECTICAL CONTRACTOR REGARDING ELECTRICAL ROUGH-INS NECESSARY TO POWER ALL SECURITY SYSTEMS AND DEVICES. NEW GYP BOARD CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION NEW APC CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION NEW LIGHTING SWITCH: X - NUMBER OF POLES SCHEMATIC WIRE EXHAUST DIFFUSER - MATCH BUILDING STANDARD CEILING SYMBOLS x RETURN DIFFUSER - MATCH BUILDING STANDARD NEW SUPPLY DIFFUSER - MATCH BUILDING STANDARD NEW LIGHT FIXTURE: - 6" RECESSED LED CAN LIGHT - REFER TO LIGHTING PLAN NEW LIGHT FIXTURE - OCCUPANCY SENSOR - 2' WIDE WALL MOUNT LIGHT FIXTURE - REFER TO LIGHTING PLAN 2' NEW LIGHT FIXTURE - 2'x4' LAY-IN INDIRECT FLUORESCENT - REFER TO LIGHTING PLAN NEW LIGHT FIXTURE - 2'x4' LAY-IN TROFFER - REFER TO LIGHTING PLAN NEW EXIT SIGN FIXTURE - CEILING MOUNT LED EXIT SIGN - REFER TO LIGHTING PLAN EXISTING APC CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION EXISTING GYP BOARD CEILING - REFER TO TYPES SHEET FOR ADDITIONAL INFORMATION TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:56 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A141 REFLECTED CEILING PLAN 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 1/4" = 1'-0" ? 1 REFLECTED CEILING PLAN REFLECTED CEILING PLAN NOTES 1 MECHANICAL AND LIGHT FIXTURES TO REMAIN AS IS UNLESS NOTED OTHERWISE. 2 CEILING MOUNTED EXAM LIGHT PROVIDED BY TENANT, INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND INSTALL UNISTRUT CEILING MOUNTED LIGHT SUPPORT. CONTRACTOR TO PROVIDE 120V DEDICATED CIRCUIT FOR FIXTURE. 3 TIE EXTENDED BULKHEAD INTO EXISTING BULKHEAD. MATCH HEIGHT, RADIAL CURVATURE, AND TYPE OF EXISTING, ADJACENT CEILING TYPE. 4 LIGHT TO BE ON OCCUPANCY SENSOR. 5 ROOM TO RECEIVE 24-7 EXHAUST FAN. 6 INSTALL SALVAGED LIGHT FIXTURE IN ROOM. 116 413 SF CORRIDOR 121 416 401 400 406 402 405 405 405 405 405 101 106 406 402 406 402 413 413 409 409 408 410 410 305 302 302 100 101 404 301 300 414 403 100 101 102 302 100 101 417 100 101 404 302 105 100 101 407 302 400 406 400 407 402 400 402 406 407 304 304 304 304 304 412 A301 7 NOT IN SCOPE STAIR A301 9 A301 8 107 108 100 101 100 109 109 109 109 109 109 109 109 109 109 109 404 404 404 109 TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:54 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A131 EQUIPMENT & FURNITURE PLAN 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 1/4" = 1'-0" ? 1 FURNITURE & EQUIPMENT PLAN EQUIPMENT SCHEDULE MARK Description Basis of Design Provided By 304 SHARPS CONTAINER BD 305017 MCKESSON 100 - CONTRACTOR-FURNISHED/CONTRACTOR-INSTALLED 100 PAPER TOWEL DISPENSER BOBRICK B-2621 CONTRACTOR 101 SOAP DISPENSER BOBRICK B-2112 CONTRACTOR 102 MIRROR - 24" X 36" BOBRICK B-290 CONTRACTOR 103.1 GRAB BAR - 24" BOBRICK B-5806.99 CONTRACTOR 103.2 GRAB BAR - 36" BOBRICK B-5806.99 CONTRACTOR 103.3 GRAB BAR - 42" BOBRICK B-5806.99 CONTRACTOR 104 TOILET PAPER DISPENSER ASI - 0710 CONTRACTOR 105 FULL SIZE REFRIGERATOR/FREEZER FRIGIDAIRE - FFTR2021QWIM116000 CONTRACTOR 106 MICROWAVE WHIRLPOOL - WMC30516AS CONTRACTOR 107 FIRE EXTINGUISHER CABINET BUILDING STANDARD CONTRACTOR 108 FIRE EXTINGUISHER BUILDING STANDARD CONTRACTOR 109 COAT HOOK (SINGLE) YH756#CP CONTRACTOR 300 - TENANT-FURNISHED/CONTRACTOR INSTALL 300 WATER COOLER BY TENANT TENANT 301 FLAT SCREEN TELEVISION & MOUNT EXIST. TENANT 302 GLOVE BOX HOLDER MCKESSON - 16-6530 MCKESSON 305 MDIMARK CEILING MOUNTED PROCEDURE LIGHT RITTER 255 LED PROCEDURE LIGHT MCKESSON 400 -TENANT-FURNISHED/TENANT-INSTALLED 400 EXAM TABLE RITTER 204 MCKESSON 401 TREATMENT TABLE RITTER 223 MCKESSON 402 MOBILE LAPTOP CART MIDMARK 6204 MCKESSON 403 MOBILE BP & TEMP WELCH ALLYN 7670-03 MCKESSON 404 STEP ON BIO WASTE CAN MCKESSON - 4876 MCKESSON 405 STEP-ON WASTE CAN MCKESSON - 81-25268 MCKESSON 406 MOBILE EXAM STOOL MIDMARK 272 MCKESSON 407 MOBILE EXAM LIGHT MCKESSON - 80-18100 MCKESSON 408 UNDER-COUNTER REFRIGERATOR BY TENANT TENANT 409 MAYO STAND MCKESSON - 640185 MCKESSON 410 BOVIE MACHINE BY TENANT TENANT 412 LASER & CART BY TENANT TENANT 413 DESKTOP PRINTER BY AHIS AHIS 414 FREESTANDING PRINTER BY AHIS AHIS 416 DIGITAL SCALE HEALTHOMETER 1100KLHR MCKESSON 417 AUTOCLAVE MIDMARK - M11-022 MCKESSON 117 159 SF BREAK ROOM 116 4 3 4 5 413 SF CORRIDOR 121 6 A301 2 A301 1 A301 6 A301 4 A301 3 A301 5 A301 7 NOT IN SCOPE STAIR 2 2 2 2 2 2 2 2 5 5 5 A301 7 A301 7 7 101 103 104 105 110 118 117 116 113 112 111 A301 9 2 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 A301 9 A301 9 8 8 A301 10 Sim A301 10 Sim A301 10 Sim A301 10 Sim 1 1 1 A301 8 8 9 10 100A EXIST. 106 EXIST. 107 EXIST. 108 EXIST. 120 EXIST. 119 EXIST. 109 EXIST. 114 EXIST. 100B EXIST. 104 SF EXAM 1 103 104 SF EXAM 2 104 143 SF TREATMENT 120 66 SF STORAGE 119 92 SF OFFICE 118 457 SF WAITING 100 156 SF ESTHETICIAN 109 232 SF FRONT OFFICE 101 44 SF CLEAN LINEN 107 40 SF TLT- PATIENT 108 11 SF SOILED 113 128 SF OFFICE/ CONSULT 110 12 SF BIO 112 48 SF CHECK OUT 102 79 SF CORR. 114 104 SF EXAM 3 105 20 SF STORAGE 111 175 SF MA STATION 106 79 SF OFFICE 117 159 SF BREAK ROOM 116 413 SF CORRIDOR 121 A301 2 A301 1 A301 6 A301 4 A301 3 A301 5 A301 7 NOT IN SCOPE STAIR 113 112 111 116 101 110 118 105 104 103 117 A301 9 A301 9 A301 9 A301 7 A301 7 A301 10 Sim A301 10 Sim A301 10 Sim A301 10 Sim A301 8 +/- 9' - 9" +/-9' 11" +/- 9' - 6" +/- 8' - 8" +/- 9' - 2" CLEAR 5' - 0" ALIGN F.F. ALIGN F.F. ALIGN F.F. 2' - 3 3/8" 6' - 1 1/4" 3' - 10 1/4" 4' - 0 5/8" +/- 6' - 7 3/4" +/- 11' - 0" 5' - 7 1/4" 3' - 0 3/4" +/- 12' - 3" CLEAR 5' - 3" ALIGN F.F. +/- 12' - 0" TYP. 1' - 0" EQ EQ ALIGN F.F. 5' - 0" 5' - 0" 6" 6" TYP. 1' - 6" 3' - 0" 1' - 1" 5' - 0" 1' - 0" 1' - 0" 1' - 0" 100A EXIST. 106 EXIST. 109 EXIST. 120 EXIST. 119 EXIST. 114 EXIST. 108 EXIST. 107 EXIST. 100B EXIST. TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:52 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A111 NEW CONSTRUCTION & DIMENSION PLANS 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 FLOOR PLAN NOTES 1 REINSTALL DOOR WITH EXISTING DECORATIVE GLASS SIDELITE. VERIFY DECORATIVE GLASS SIZE PRIOR TO ORDERING DOOR FRAME. 2 COORDINATE FURNITURE AND CASEWORK PROVIDED BY FURNITURE VENDOR, INCLUDING BLOCKING. 3 NEW 25" D. PLASTIC LAMINATE COUNTERTOP. 4 PLASTIC LAMINATE TRANSACTION SURFACE. REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION. 5 OFFICEWORKS TO PROVIDE CASEWORK, SINK AND DRAIN. CONTRACTOR TO PROVIDE PLUMBING ROUGH-IN. CONTRACTOR AND OFFICEWORKS TO COORDINATE FINAL ROUGH-IN LOCATIONS PRIOR TO INSTALLATION. 6 NEW CEILING MOUNTED EXAM LIGHT. CONTRACTOR TO PROVIDE CEILING SUPPORT AND APPROPRIATE ELECTRICAL NEEDS. TENANT IS TO PURCHASE PIECE OF EQUIPMENT AND HAVE ON SITE FOR THE CONTRACTOR TO INSTALL PER THE MANUFACTURERS DIRECTIONS. 7 REINSTALL FLAT SCREEN TELEVISION AND WALL MOUNT. 8 REPAIR GYP. BOARD WHERE CASEWORK, FIXTURE, WALL OR OTHER DEMOLISHED ITEMS WERE REMOVED. PREP WALL FOR PAINT. 9 REPLACE EXISTING MIRROR. SOAP AND PAPER TOWEL DISPENSERS. 10 ALIGN NEW SECTION OF PARTIAL WALL WITH EXISTING RADIUS WALL SYSTEM. 1/4" = 1'-0" ? 1 NEW CONSTRUCTION PLAN 1/4" = 1'-0" ? 2 DIMENSION PLAN 6 7 6 7 7 7 7 7 7 7 7 7 7 7 TREATMENT TREATMENT TREATMENT TREATMENT DRESS DRESS DRESS DRESS DRESS CORRIDOR CORRIDOR CORRIDOR READING ROOM TECH AREA DRESS STORAGE STORAGE STORAGE TOILET SUB-WAIT RECEPTION WAITING 8 8 8 8 8 8 8 8 9 2 4 10 10 11 11 11 2 12 13 13 13 13 10 10 10 11 11 14 14 14 14 14 14 14 14 11 10 10 13 15 6 6 CORRIDOR 101 102 104 103 105 114 113 115 106 121 112 106 119 120 117 116 108 109 110 111 107 100 118 NOT IN SCOPE NOT IN SCOPE STAIR 1 1 1 TRUE NORTH arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:49 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A101 DEMOLITION PLAN 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 DEMOLITION PLAN NOTES 1 REMOVE AND SALVAGE DOOR FRAME AND HARDWARE. 2 REMOVE CASEWORK/MILLWORK. 3 REMOVE POCKET DOOR. 4 REMOVE PLUMBING FIXTURE. 5 REMOVE SOLID SURFACE COUNTERTOP. 6 REMOVE CEILING WITHIN ROOM. REMOVE ALL EXISTING LIGHT FIXTURES. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. REMOVE ALL EXISTING HVAC DIFFUSERS. REFER TO HVAC DRAWINGS FOR ADDITIONAL INFORMATION. 7 REMOVE EXISTING FLOORING MATERIAL AND WALL BASE. 8 DEMO EXISTING GYP. BOARD CEILING AND BULKHEAD. 9 REMOVE AND SALVAGE EXISTING INTERIOR WINDOW AND FRAME. 10 REMOVE EXISTING IMAGING EQUIPMENT AND PATCH WALL. 11 DISCONNECT AND SALVAGE EXISTING VIEW BOX AND RETURN TO OWNER. 12 EXISTING CEILING MOUNTED LIGHT TO REMAIN. PROTECT FROM DAMAGE. 13 REMOVE EXISTING PRIVACY CURTAIN TRACK AND HARDWARE. 14 REMOVE VALANCES ON EXTERIOR WINDOWS. 15 DISCONNECT AND SALVAGE FLAT SCREEN TV AND WALL MOUNTED BRACKET FOR REUSE. PROTECT FROM DAMAGE. REFER TO ELECTRICAL PLAN FOR REINSTALLATION DETAILS. 1/4" = 1'-0" ? 1 DEMOLITION PLAN & ACCESSORIES 1' - 3" MIN IF ADJACENT TO WALL U.N.O. 1' - 1" 1' - 1" 2' - 10" 3' - 5" PLAM APRON, PER TYP CASEWORK DETAILS 1' - 6" 1' - 6" NOTE: DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL. 6" 1' - 0" 2' - 0" 2' - 11" WATER CLOSET - FRONT VIEW WALL OR STALL 36" GRAB BAR 8" 1' - 3" 2' - 6" 2' - 4" 1' - 0" 2' - 11" 5" WATER CLOSET - SIDE VIEW 1' - 6" 3' - 6" 1' - 3"1' - 3" URINAL WALL HUNG SCREENS, 24" WIDE MAX 1' - 5" 4' - 0" HOUSEKEEPING CLOSET MOP SINK STAINLESS STEEL WALL PROTECTION AT SIDE & REAR TYP. AT MOP SINKS W/O WALL PROTECTION OR TILE SCHEDULED 4' - 6" 4'-0" O.C. MAXIMUM SHELF SUPPORT SPACING 16" DEEP SHELF FINISHED FLOOR MECHANICAL, ELECTRICAL, COMMUNICATIONS, AND FIRE PROTECTION FINISHED FLOOR 1' - 6" 3' - 8" DATA AND ELECTRICAL OUTLETS 3' - 8" 2' - 0" 2' - 6" 3' - 8" 3' - 0" 3' - 8" 1' - 6" 3' - 6" DATA AND ELECTRICAL OUTLETS AT COUNTERS ADJACENT OUTLETS GANGED TOGETHER W/ 1 FACEPLATE 3' - 8" FULL HEIGHT EQUIPMENT 1' - 6" 3' - 4" UNDER COUNTER EQUIPMENT 3' - 8" 2' - 0" ABOVE COUNTER EQUIPMENT 3' - 8" EQ EQ DATA AND ELECTRICAL OUTLETS IN ALCOVE 6" 8" 1' - 0" 4" LIGHT SWITCH HAND SANITIZER TELEPHONE CLOCK ALIGN ACCESSORIES ADJACENT TO DOOR 3' - 8" CODE BLUE 3' - 8" CARD SWIPE TO BE INSTALLED NEXT TO DOOR. PUSH BUTTONS (TYP) FOR COMBINED FUNCTION 8" 3' - 2" DOOR PUSH BUTTON 30"X48"APPROACH TO PUSH BUTTON MUST BE LOCATED BEYOND ARC OF DOOR SWING DOOR FRAME MIN. 8' - 0" PLAN DOOR PUSH BUTTON 3' - 8" DUTY STATION 4' - 6" FIRE EXTINGUISHER CABINET MECHANICAL, ELECTRICAL, COMMUNICATIONS, AND FIRE PROTECTION FINISHED FLOOR 5" 3' - 10" HEIGHT AND SPACING FOR MEDICAL GAS OUTLETS 6" TYP. SPACING CLEAR VACUUM CANISTER, LOCATED NEXT TO VAC OUTLET - TYP. NURSE CALL A N WNOO V 4' - 6" MEDICAL GAS ALARM PANEL 3' - 6" CLEAR 1' - 0" CLEAR 1' - 0" MEDICAL GAS ZONE VALVE BOX 3' - 10" 2' - 10 1/2" (TOILETS) 4" (SHOWERS) ADJACENT WALL NURSE CALL DOOR FRAME TELEPHONE WALL MOUNTED 4' - 0" 1' - 11" IF ADJACENT TO DOOR GENERAL DEVICE ALIGNMENT DIAGRAM 6" 1' - 6" 3' - 8" 5' - 0" TO BOTTOM OF STROBE LENS 6' - 8" LIFE SAFETY DEVICES - CENTER ABOVE ELEC DEVICES, SIGNS, OR FEC BELOW WALL MTD SIGNAGE, WHERE SCHED LIGHT SWITCHES, CARD READER, THERMOSTAT VOICE/DATA/POWER DEVICES, UON LOCATE DEVICES 6" FROM DOOR/WALL OPNG, OR AS DIMENSIONED, WHERE NOT DIMENSIONED, LOCATE @ NEAREST MET STUD FROM LOCATION SHOWN ON FLOOR PLAN ACCESSORIES & MEDICAL EQUIPMENT FINISHED FLOOR MIN 1' - 3" MAX 4' - 0" GENERAL REACH RANGE FOR MIN AND MAX HEIGHTS UNLESS NOTED OTHERWISE 6' - 0" BULLETIN BOARD & WHITE BOARD 4' - 0" DIAGNOSTIC SET, INSTRUMENT WALL PANEL ADJACENT WALL 2" TYP. SPACING 2" TYP. SPACING 2" TYP. SPACING SPACING BETWEEN ACCESSORIES 3' - 8" GLOVES 5' - 0" QUAD GLOVES, VERTICAL HAND SANITIZER - WALL MOUNTED DOOR FRAME 1' - 2" IF ADJACENT TO DOOR 3' - 8" ACCESSORIES & MEDICAL EQUIPMENT FINISHED FLOOR LOCKER - 2 TIER SLOPED TOP, TYPICAL AT LOCKERS 6' - 0" 6' - 0" 3' - 0" MIRROR FULL HEIGHT MIRROR LAVATORY 4' - 2" MONITOR, DIGITAL AREA 4' - 6" PAPER CUP DISPENSER 4' - 0" 6' - 0" HOOK ADA MOUNT HOOK HIGH MOUNT 6' - 0" HOOK PER ADA AT 4' - N 0" MAX ON-ADA ROOM 6' - 0" HOOK AT DOOR EQ EQ 6" TYP. COAT HOOK FLOOR PLAN COAT HOOK AT DOOR 4' - 0" SHARPS 3' - 8" SHARPS- ABOVE COUNTER 3' - 0" 3' - 2" SHARPS- ABOVE WALL PROTECTION 3' - 0" 4' - 0" SHARPS/GLOVES SHARPS/GLOVES ABOVE WALL PROTECTION 3' - 0" 3' - 2" 4' - 0" SHELF WITH HOOKS 4' - 0" SPHYG MIN 1' - 3" STORAGE, BIN WALL 4' - 0" THERMOMETER BRACKET 4' - 0" TOWEL BAR- WALL MOUNTED FINISHED FLOOR WALL PROTECTION 4" TO CEILING CORNER GUARD CG1 BASE, AS SCHEDULED 7' - 2" 3" CORNER GUARD OR DOOR JAMB HANDRAIL BASE, AS SCHEDULED WALL PROTECTION, TERMINATION AT CORNER 42" GRAB BAR 18" GRAB BAR TOILET PAPER DISP. SANITARY NAPKIN 2' - 0" SHEET WALL PROTECTION OUTLET 2' - 6" MOUNTING HEIGHT NOTES: 1. REFER TO FLOOR PLANS AND INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 2. REFER TO ELECTRICAL AND DATA DRAWINGS FOR ADDITIONAL INFORMATION AND DEVICE MOUNTING HEIGHTS. 3. COORDINATE IN-WALL BLOCKING AS NECESSARY. REFER TO EQUIPMENT DRAWING FOR MINIMUM BLOCKING REQUIREMENTS. 4. WHERE CONFLICTS OCCUR BETWEEN THE TYPICAL MOUNTING HEIGHTS SHEET, INTERIOR ELEVATIONS, FLOOR PLANS AND MEP DRAWINGS COORDINATATE CONFLICTS WITH THE ARCHITECT. arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:48 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A003 TYPICAL MOUNTING HEIGHTS 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL/NJA 30102 1/4" = 1'-0" ? 1 TYPICAL MOUNTING HEIGHTS WALL NAMING CONVENTION A INTERIOR WALL TYPES NOTES REFER TO THE GENERAL NOTES ON SHEET A001 FOR ADDITIONAL REQUIREMENTS. A. WHERE INSULATION IS PRESENT WITHIN STUD CAVITY, AT INTERIOR WALLS, AND GYPSUM BOARD IS NOT PRESENT, PROVIDE "CHICKEN WIRE" TO SECURE INSULATION WITHIN THE STUD CAVITY. B. ALL WALL TYPES ARE TO BE TYPE 'S4' UNLESS NOTED OTHERWISE. C. ALL GYPSUM BOARD (GB) IS TYPE X UNLESS NOTED OTHERWISE. D. BOTTOM EDGE OF GYPSUM BOARD SHALL BE HELD ABOVE THE SLAB / SUBFLOOR A MINIMUM OF 1/2". E. IN A ROOM THAT DOES NOT HAVE A CEILING, THE GYPSUM BOARD SHALL EXTEND TO THE DECK ABOVE ON THE SIDE OF THE WALL WHERE THE CEILING IS NOT PRESENT. F. ALL WALLS GOING TO DECK TO HAVE MOLD AND MOISTURE RESISTANT GYPSUM BOARD FROM 6" ABOVE CEILING LINE TO DECK. G. AT ALL WALLS SCHEDULED TO RECEIVE CERAMIC TILE, CONTRACTOR SHALL SUBSTITUTE GLASS MAT INTERIOR GYPSUM WALLBOARD FOR THE STANDARD GYPSUM WALLBOARD IDENTIFIED IN THE WALL TYPES. REFER TO ROOM FINISH SCHEDULE FOR LOCATIONS OF CERAMIC TILE. H. PROVIDE 4'-0" WIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD CENTERED BEHIND ALL PLUMBING FIXTURES. I. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON ALL WALLS INTERSECTING EXTERIOR WALLS FOR THE FIRST 4'-0" OF THE WALL ADJACENT TO THE EXTERIOR WALL. J. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON WALLS OF MECHANICAL ROOMS, ELECTRICAL CLOSETS, TOILET ROOMS AND HOUSEKEEPING ROOMS. K. ANY PATCHING AND REPAIRING TO EXTERIOR WALL GYPSUM BOARD TO BE DONE WITH MOLD AND MOISTURE RESISTANT GYPSUM BOARD. L. ALL FRAMING SHALL BE 20 GUAGE UNLESS NOTED OTHERWISE. M. IN NONRATED WALLS WITH GYPSUM BOARD TO DECK SEAL ALL JOINTS AND PENETRATIONS WITH TAPE, JOINT COMPOUND, SEALANT TO SEAL ALL GAPS. N. PROVIDE REINFORCED CORNER FRAMING AT ALL EXPOSED CORNERS AND END WALLS. REFER TO DETAIL. O. REPAIRS TO EXISTING RATED WALLS MUST BE REPAIRED TO MATCH RATING REQUIREMENTS. INTERIOR CEILING TYPES NOTES REFER TO THE GENERAL NOTES ON SHEET A-001 FOR ADDITIONAL REQUIREMENTS. A. REFER TO CEILING PLANS FOR CEILING LOCATIONS. B. METAL STUD FRAMING IN LIEU OF WOOD STUD FRAMING. C. ALL NEW ACOUSTIC PANEL CEILING TILE AND SUSPENDED GRID SYSTEM TO MATCH EXISTING. D. ALL GYP. BD. BULKHEAD BOTTOM FACE OF GYP. BD. TO RECEIVE (PT4). CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLOOR SLAB/STRUCTURE ABOVE ROOF/CEILING TRUSS/STRUCTURE PROVIDE "ZIP-STRIP" TRIM AT TOP EDGE OF GYPSUM BOARD AT FINISHED CEILINGS. WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES - SEE PLANS CONTINUOUS METAL STUD TRACK ANCHORED TO EXISTING FLOOR METAL STUD FRAMING 5/8" TYPE X GYPSUM BOARD U.N.O. 1/2" HEAD PLAN BASE 'S4.2i' SOUND BATTS (SAB) WHERE INDICATED. ACOUSTIC SEALANT AT INSULATIVE WALLS. FIRE-RESISTIVE JOINT SYSTEM AS REQUIRED TO MAINTAING RATING INDICATED, AT JUNCTURE OF GYPSUM BOARD AND FLOOR/CEILING ASSEMBLY. FIRE-RESISTIVE JOINT SYSTEM AT ALL GB PENETRATIONS IN RATED WALLS CONTINUOUS FIRE-RESITIVE JOINT SYSTEM AS REQUIRED BY RATING INDICATED AND DECK ORIENTATION CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLOOR SLAB/STRUCTURE ABOVE ROOF/CEILING TRUSS/STRUCTURE CONTINUOUS SEALANT BEAD AT JUNCTURE OF GYPSUM BOARD AND FLOOR/CEILING ASSEMBLY WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES - SEE PLANS CONTINUOUS METAL STUD TRACK ANCHORED TO FLOOR METAL STUD FRAMING 5/8" TYPE X GYPSUM BOARD U.N.O. HEAD PLAN BASE 'Sx.1' 1/2" SOUND BATTS (SAB) WHERE INDICATED. ACOUSTIC SEALANT AT INSULATIVE WALLS. HARD LID ABOVE LID WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES - SEE PLANS CONTINUOUS METAL STUD TRACK ANCHORED TO EXISTING FLOOR METAL STUD FRAMING. 5/8" TYPE X GYPSUM BOARD U.N.O 1/2" 'S4' U.N.O. 6" KICKER BRACING TO STRUCTURE ABOVE AT 48" O.C. MAX. HEAD PLAN BASE SOUND BATTS (SAB) WHERE INDICATED. ACOUSTIC SEALANT AT INSULATIVE WALLS. 2'-0" WIDE (SAB) AT INSULATIVE WALLS. arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:46 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A002 TYPES 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 PANELS AT BORDERS. D. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS, PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM. SPLAY HANGERS ONLY WHERE REQUIRED AND, IF PERMITTED WITH FIRE-RESISTANCE- RATED CEILINGS, TO MISS OBSTRUCTIONS; OFFSET RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION WITHIN CEILING PLENUM PRODUCES HANGER SPACINGS THAT INTERFERE WITH LOCATION OF HANGERS, USE TRAPEZES OR EQUIVALENT DEVICES. WHEN STEEL FRAMING DOES NOT PERMIT INSTALLATION OF HANGER WIRES AT SPACING REQUIRED, INSTALL CARRYING CHANNELS OR OTHER SUPPLEMENTAL SUPPORT FOR ATTACHMENT OF HANGER WIRES. E. DO NOT SUPPORT CEILINGS DIRECTLY FROM PERMANENT METAL FORMS OR FLOOR DECK; ANCHOR INTO CONCRETE SLABS. F. DO NOT ATTACH HANGERS TO STEEL DECK TABS OR TO STEEL ROOF DECK. G. INSTALL EDGE MOLDINGS AND TRIM OF TYPE INDICATED AT PERIMETER OF ACOUSTICAL CEILING AREA AND WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL PANELS. SCREW ATTACH MOLDINGS TO SUBSTRATE AT INTERVALS NOT MORE THAN 16 INCHES (400 MM) O.C. AND NOT MORE THAN 3 INCHES (75 MM) FROM ENDS, LEVELING WITH CEILING SUSPENSION SYSTEM TO A TOLERANCE OF 1/8 INCH IN 12 FEET (3.2 MM IN 3.6 M). MITER CORNERS ACCURATELY AND CONNECT SECURELY. H. INSTALL SUSPENSION SYSTEM RUNNERS SO THEY ARE SQUARE AND SECURELY INTERLOCKED WITH ONE ANOTHER. REMOVE AND REPLACE DENTED, BENT, OR KINKED MEMBERS. I. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW AND ACCORDING TO ASTM C 840: LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW UNLESS OTHERWISE INDICATED. REFER TO INTERIOR FINISH DRAWINGS FOR GYPSUM BOARD BULKHEAD FINISH DETAILS. J. REFER TO ELECTRICAL PLAN AND PLUMBING PLAN FOR GENERAL NOTES. K. ALL LAY-IN ACOUSTICAL CEILING TILE SHALL BE INSTALLED TO MATCH THE EXISTING ACOUSTIC PANEL CEILING AND GYP. BD. CEILINGS UNLESS NOTED OTHERWISE. GENERAL DEMOLITION NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. DEFINITIONS • REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFF-SITE UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED. • REMOVE AND SALVAGE: CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. • REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED. • EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE PERMANENTLY REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, REMOVED AND SALVAGED, OR REMOVED AND REINSTALLED. A. CONDITIONS EXISTING AT TIME OF INSPECTION FOR BIDDING PURPOSE WILL BE MAINTAINED BY OWNER AS FAR AS PRACTICAL. B. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION. C. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE IS NOT PERMITTED. D. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. E. MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING SELECTIVE DEMOLITION OPERATIONS. F. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND AS INDICATED IN DIVISION 2 SECTION "SELECTIVE STRUCTURE DEMOLITION". G. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS AND TRANSPORT ITEMS TO STORAGE AREA DESIGNATED BY OWNER. H. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED. I. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. J. DISPOSAL OF DEMOLISHED MATERIALS: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS. COMPLY WITH REQUIREMENTS SPECIFIED IN DIVISION 01 SECTION "CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL." K. DO NOT BURN DEMOLISHED MATERIALS. L. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY DISPOSE OF THEM. M. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN. N. RELOCATE/REMOVE EXISTING ELECTRICAL DEVICES IN EXISTING WALLS AS REQUIRED TO MATCH NEW ELECTRICAL PLANS. O. REMOVE SIGNAGE IN SUITES WITHIN THE PROJECT SCOPE. RETURN TO OWNER AS NEEDED. P. REMOVE GYPSUM BOARD AS REQUIRED IN EXISTING WALLS RECEIVING NEW ELECTRICAL, MECHANICAL, PLUMBING FIXTURES/DEVICES. Q. REMOVE GYPSUM BOARD, VAPOR BARRIER AND ALL DAMAGED INSULATION ON INTERIOR FACE OF EXTERIOR WALLS AS NEEDED. R. PROVIDE APPROPRIATE DUST PARTITION AND CONTRACTOR ACCESS DOOR TO ISOLATE CONSTRUCTION AREA. GENERAL CASEWORK NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ADA, AMERICANS WITH DISABILITIES ACT REQUIREMENTS: THE FOLLOWING SPECIAL REQUIREMENTS SHALL BE MET, WHERE SPECIFICALLY INDICATED ON ARCHITECTURAL PLANS AS "ADA", OR BY GENERAL NOTE. B. COUNTERTOP HEIGHT: WITH OR WITHOUT CABINET BELOW, NOT TO EXCEED A HEIGHT OF 36 INCHES (864 MM) A.F.F., (ABOVE FINISHED FLOOR), AT A SURFACE DEPTH OF 24 INCHES (610 MM). C. KNEESPACE CLEARANCE: SHALL BE MINIMUM 29 INCHES (737 MM) A.F.F. AT APRON, AND 30 INCHES (762 MM) CLEAR SPAN WIDTH. D. 12 INCH (305 MM) DEEP SHELVING, ADJUSTABLE OR FIXED: NOT TO EXCEED A RANGE FROM 9 INCHES (229 MM) A.F.F. TO 54 INCHES (1372 MM) A.F.F. E. METAL FRAME AND METAL BACKING STRAP: FASTEN WALL CABINETS THROUGH BACK, NEAR TOP AND BOTTOM, AT ENDS AND NOT LESS THAN 24 INCHES (600 MM) O.C., WITH TOGGLE BOLTS THROUGH METAL BACKING BEHIND GYPSUM BOARD. F. FASTEN PLASTIC-LAMINATE COUNTERTOPS BY SCREWING THROUGH CORNER BLOCKS OF BASE UNITS INTO UNDERSIDE OF COUNTERTOP. FORM SEAMS USING SPLINES TO ALIGN ADJACENT SURFACES, AND SECURE WITH GLUE AND CONCEALED CLAMPING DEVICES DESIGNED FOR THIS PURPOSE. G. ADJUST EXISTING CABINETS AND HARDWARE SO DOORS AND DRAWERS ARE CENTERED IN OPENINGS AND OPERATE SMOOTHLY WITHOUT WARP OR BIND. LUBRICATE OPERATING HARDWARE AS RECOMMENDED BY MANUFACTURER. H. CLEAN ALL SURFACES OF CASEWORK PRIOR TO SUBSTANTIAL COMPLETION. I. ON ALL PLASTIC LAMINATE COUNTERTOPS PROVIDE 3mm PVC EDGE ON EXPOSED EDGES TO MATCH LAMINATE, RADIUS EDGE ON ALL EXPOSED CORNERS AND 4" TALL APPLIED SIDE AND BACKSPLASHES WHERE SHOWN IN ELEVATIONS. J. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK. REFER TO INTERIOR FINISH PLAN AND INTERIOR ELEVATIONS FOR MATERIAL SELECTIONS. K. COORDINATE BULKHEAD HEIGHTS INDICATED ON INTERIOR ELEVATIONS WITH THAT SHOWN ON THE REFLECTED CEILING PLAN. GENERAL INTERIOR ELEVATION NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. PROVIDE METAL COUNTERTOP BRACKETS AT 32" O.C. MAX. PROVIDE IN-WALL BLOCKING AS REQUIRED. BRACKETS TO MATCH WALL PAINT COLOR. B. PROVIDE 2 1/2" GROMMETS IN WORKSURFACES WHERE POWER/DATA RECEPTACLES ARE BELOW COUNTER. COORDINATE FINAL GROMMET LOCATION WITH OWNER PRIOR TO INSTALLATION. C. EQUIPMENT NUMBERS IN ELEVATION REFERENCE THE EQUIPMENT SCHEDULE. GENERAL PROJECT NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES. B. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. C. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. D. THE GENERAL CONTRACTOR SHALL COORDINATE AN APPROPRIATE DUMPSTER LOCATION WITH THE LANDLORD. E. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. F. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB CLEANLINESS. G. THE CONTRACTOR(S) IS TO PROVIDE A COMPLETE, FINISHED AND FUNCTIONAL INSTALLATION OF ALL COMPONENTS DESCRIBED IN THESE DRAWINGS. H. THE GENERAL CONTRACTOR SHALL LABEL ALL RATED WALLS ABOVE CEILING. I. ALL AREAS OF DEPICTED WORK EXIST IN A BUILDING THAT IS CURRENTLY OCCUPIED. THE CONTRACTOR SHALL COORDINATE WORK, TIME AND ACCESS WITH ST. VINCENT HEALTH AND/OR MEDXCEL'S PROPERTY MANAGER AND STRIVE TO ENSURE THEIR WORK IN NO WAY ADVERSELY AFFECTS THE ADJACENT OCCUPIED SPACES. J. THE ARCHITECT HAS MADE HIS BEST EFFORTS TO COMPLY WITH THE AMERICAN WITH DISABILITIES ACT (ADA). IF ANY PORTION OF THIS WORK IS FOUND TO BE IN CONFLICT WITH ADA COMPLIANCE, THE ARCHITECT SHALL BE NOTIFIED, IN WRITING, BY THE CONTRACTOR IMMEDIATELY. K. WARRANT TO THE OWNER THAT ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW. UNLESS NOTED OTHERWISE SPECIFIED, AND THAT ALL WORK SHALL BE OF GOOD QUALITY, FREE FROM DEFECTS AND FAULTS, AND CONFORMS TO THE CONTRACT DOCUMENTS. L. ALL MECHANICAL, PLUMBING AND ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. M. VERIFY WITH TENANT AND LANDLORD ALL BUILDING STANDARD MATERIALS AND SYSTEMS. SYMBOL LEGEND X WALL TYPE ELEVATION TAG DETAIL TAG SECTION DETAIL TAG WINDOW/LOUVER AND FRAME TAG FLOOR PLAN NOTE TAG REFLECTED CEILING PLAN NOTE TAG DEMOLITION PLAN NOTE TAG DOOR NUMBER TAG CEILING/BULKHEAD TAG WALL TO BE DEMOLISHED WALL TO REMAIN/NEW WALLS DOOR AND FRAME TO BE REMOVED INTERIOR ELEVATION NOTE TAG XXXXX XX MIN RV X XX 1 TOILET ACCESSORY TAG - REFER TO SPECIFICATIONS TA-XX X'-X" 1 1 REVISION TAG ROOM TAG XX XXXX X A101 1 SIM XX XXXX UNIT - EXTERIOR/INTERIOR ELEVATION TAG NORTH ARROW View Name 1 1/16" = 1'-0" REFERENCE: 1 / AF101 DRAWING TITLE RATING REMARKS/VOLTAGE HARDWARE SET DOOR TYPE DATUM POINT 1 CASEWORK/EQUIPMEN T TAG 0 COLUMN GRID DESIGNATION 1 1 1 CEILING TYPE CEILING HEIGHT XX XXXX X XXXX INDICATES SIMILAR DETAIL REFERENCING VIEW SCALE XXX ROOM KEY NOTE (OFFICE USE ONLY) SPECIFICATION SECTION 00 00 00 . A1 TEXT NOTATION MATERIAL LEGEND CONCRETE MASONRY UNIT FACE BRICK CONCRETE EARTH METAL/STEEL PLYWOOD FINISHED WOOD WOOD BLOCKING RIGID INSULATION INSULATION - BATT/LOOSE GYPSUM BOARD WOOD SHIM CONTRACTORS TO PROCURE PRODUCTS LISTED ABOVE FROM ASCENSION'S NATIONAL ACCOUNT THROUGH GRAINGER 07 84 00 FIRESTOPPING STI (SPECIFIED TECHNOLOGIES INC.) DIVISION MATERIAL APPROVED MANUFACTURER 08 12 13 H.M. FRAMES & DOORS CECO DOOR 08 14 16 FLUSH WOOD DOORS ASSA ABLOY 08 71 00 DOOR HARDWARE ASSA ABLOY 09 51 13 ACOUSTICAL PANEL CEILINGS ARMSTRONG 09 91 23 INTERIOR PAINT PRATT & LAMBERT 10 26 00 WALL AND CORNER GUARDS IN-PRO WALL PROTECTION 26 51 00 INTERIOR LIGHTING ACUITY BRANDS AND LITHONIA DIVISION MATERIAL APPROVED MANUFACTURER 12 05 00 CUBICLE CURTAINS IN-PRO 22 40 00 PLUMBING FIXTURES AMERICAN STANDARD, CHICAGO FAUCETS, DELTA AND SLOAN 26 27 26 WIRING DEVICES BRYANT-HUBBELL PRODUCT PROCUREMENT MATRIX SHOULD A CONTRACTOR CONSIDER PURCHASING THESE MATERIALS THROUGH OTHER SOURCES, THE CONTRACTOR IS TO PROVIDE THE ARCHITECT WITH THE PURCHASE COST FROM GRAINGER AND THE PURCHASE COST FROM THE OTHER SOURCES FOR EVALUATION arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:45 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A001 ARCHITECTURAL GENERAL NOTES 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 SUBMITTAL LIST SPEC SECTION SPEC ITEM SUBMITTAL 08 12 13 METAL DOOR FRAMES SHOP DRAWINGS 08 12 13 METAL DOOR FRAMES DIGITAL IMAGE OF SAMPLE 08 71 00 DOOR HARDWARE SHOP DRAWINGS 09 51 13 ACOUSTICAL PANEL CEILING DIGITAL IMAGE OF SAMPLE 09 65 00 RESILIENT FLOORING DIGITAL IMAGE OF SAMPLE 09 65 13 RESILIENT BASE DIGITAL IMAGE OF SAMPLE 09 68 00 CARPET DIGITAL IMAGE OF SAMPLE 09 91 23 PAINT DRAW DOWN SAMPLE 10 28 00 TOILET ACCESSORIES CUT SHEETS 12 35 30 CASEWORK SHOP DRAWINGS 12 36 23 PLASTIC LAMINATE COUNTERTOPS DIGITAL IMAGE OF SAMPLE 12 36 61 SOLID SURFACE COUNTERTOPS DIGITAL IMAGE OF SAMPLE 23 00 00 PLUMBING FIXTURES CUT SHEETS 26 00 00 LIGHTING FIXTURES CUT SHEETS BREAK ROOM 116 413 SF CORRIDOR 121 1HR RATED WALL 52' - 2" 47' - 0" EXIT EXIT EXIT 48' - 4" 1-HR RATED ELEVATOR SHAFT 1-HR RATED WALL ELEV. ELEV. STAIR MEN'S PUBLIC RESTROOM WOMEN'S PUBLIC RESTROOM 1-HR RATED WALL 2-HR RATED WALL 2-HR RATED WALL WON DOOR SYMBOL / LINETYPE DESCRIPTION 1 HR FIRE BARRIER 2 HR SMOKE/FIRE BARRIER SMOKE RESISTANT CORRIDOR SUITE OF ROOMS NON-RATED INCIDENTAL USE SEPARATION LIFE SAFETY PLAN LEGEND NOTE: Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling as follows: 1. Locate above suspended lay-in panel ceilings and in accessible attic spaces. 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the wording: "FIRE WALL or FIRE BARRIER – PROTECT ALL OPENINGS". PROJECT LIMITS CODE SUMMARY Indiana Building Codes (IBC 2014): 2012 IBC w/ Amendments (Building Code) 2012 IFC w/ Amendments (Fire Code) 2012 IMC w/ Amendments (Mechanical Code) 2006 IPC w/ Amendments (Plumbing Code) 2008 NFPA 70 w/ Amendments (Electrical Code) 2012 IBC Chapter 11 w/ Amendments & 2009 ANSI A117.1 (Handicapped Accessibility Code) 2007 ASHRAE 90.1 w/ Amendments (Energy Code) 2012 IFGC w/ Amendments (Fuel Gas Code) Federal: 2000 NFPA 101, Life Safety Code (LSC) 2012 ADA Standards for Accessible Design Code references are from the 2014 IBC unless otherwise noted - where the IBC and LSC address the same topic, the most strict provision is noted. Applicable Codes: Construction 2,881 SQ. FT. Area: B - Business - Doctor's Offices [Sec. 308.4, IBC] Occupancy Classificatio n: Renovation of existing doctor's offices into a new plastics doctor's office. No change in occupancy or construction type is anticipated. Project Description: Fully Covered Existing Sprinkler System: None in construction area. Existing Smoke Detector System: Smoke detectors present in corridors and fire srobes in all existing spaces. Fire Alarm System: Construction Type: 42,800 SQ. FT., 4 STORIES Building Area: ll-B arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:50:04 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP G001 LIFE SAFETY PLAN 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL/NJA 30102 1/8" = 1'-0" ? 1 LIFE SAFETY PLAN - 1ST FLOOR EXIT A003 TYPICAL MOUNTING HEIGHTS A101 DEMOLITION PLAN A111 NEW CONSTRUCTION & DIMENSION PLANS A131 EQUIPMENT & FURNITURE PLAN A141 REFLECTED CEILING PLAN A301 INTERIOR ELEVATIONS & DETAILS A510 INTERIOR FINISH PLAN &DETAILS A601 OPENING TYPES AND SCHEDULES 05 MEP E101 ELECTRICAL & SYSTEMS PLAN E102 LIGHTING PLAN MP101 HVAC/PLUMBING PROJECT LOCATION PROJECT LOCATION