HomeMy WebLinkAboutA001 ARCHITECTURAL GENERAL NOTESGENERAL FLOOR PLAN NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM ITS RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH ALL OTHER SUBCONTRACTORS AND TRADES, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THESE DOCUMENTS, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS CONTAINED THEREIN. B. THE CONTRACTOR AND ALL ITS SUBCONTRACTORS SHALL VERIFY IN THE FIELD ALL NEW AND EXISTING APPLICABLE CONDITIONS, DIMENSIONS, RELATIONSHIPS, ETC. SHOWN IN THESE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY, ITS FAILURE TO COMPLY WITH THIS REQUIREMENT. C. ALL FLOOR PLAN DIMENSIONS SHOWN ON THE NEW FLOOR PLANS ARE FROM FACE OF FINISHED WALL (WHETHER NEW OR EXISTING WALL) UNLESS INDICATED OTHERWISE BY THE DESIGNATIONS "CLR", "CLEAR", OR "MIN." COORDINATE WITH APPLICABLE NEW WALL TYPES AND WITH APPLICABLE SECTIONS/DETAILS. D. ALL NEW HOLLOW METAL (HM). DOOR FRAMES ARE LOCATED 4" FROM THE ADJACENT WALL FACE (TO OUTER EDGE OF FRAME) UNLESS DIMENSIONED OR DETAILED OTHERWISE. E. COORDINATE, PROVIDE, AND INSTALL 2X FIRE TREATED WOOD WALL BLOCKING AS REQUIRED FOR THE ANCHORAGE AND SUPPORT OF ALL NEW CASEWORK, TRIM, FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, MARKER BOARDS, TACK BOARDS, DOOR HARDWARE ACCESSORIES, ETC., AS APPLICABLE. F. ALL NEW OR EXISTING FLOOR AREAS THAT REQUIRE LEVELING WITH A CONCRETE TOPPING OR LEVELING COMPOUND SHALL BE INSTALLED SUCH THAT THE FLATNESS EQUALS 35/24 (ON ALL SLABS) AND THE LEVELNESS EQUALS (SLAB ON GRADE) AND 80% OF THAT VALUE ON ELEVATED SLABS. G. AT ALL AREAS WHERE EXISTING FLOOR COVERING OR WALL COVERING MATERIAL WAS REMOVED, THE CONTRACTOR SHALL PROPERLY PREPARE THE SURFACE TO RECEIVE NEW FINISHES. H. CONTRACTOR SHALL ENSURE THAT ANY AND ALL BACKBOXES LOCATED WITHIN 'PARTY WALLS' THAT SEPARATE ROOMS ARE NOT LOCATED BACK TO BACK OR IN THE SAME CAVITY. STAGGER BOXES ONE STUD CAVITY EITHER SIDE OF ONE ANOTHER. I. PATCH ALL EXISTING WALLS AT LOCATIONS OF NEW OR REMOVED MEP WORK. GENERAL CEILING PLAN NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ACOUSTIC PANEL CEILING SYSTEMS ARE CENTERED IN ROOMS UNLESS NOTED OTHERWISE. B. COMPLY WITH ASTM C 636, ASTM E 580, AND SEISMIC DESIGN REQUIREMENTS INDICATED, PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND CISCA'S "CEILING SYSTEMS HANDBOOK." C. MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL PANELS TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING. AVOID USING LESS-THAN-HALF-WIDTH PANELS AT BORDERS. D. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS, PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM. SPLAY HANGERS ONLY WHERE REQUIRED AND, IF PERMITTED WITH FIRE-RESISTANCE- RATED CEILINGS, TO MISS OBSTRUCTIONS; OFFSET RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION WITHIN CEILING PLENUM PRODUCES HANGER SPACINGS THAT INTERFERE WITH LOCATION OF HANGERS, USE TRAPEZES OR EQUIVALENT DEVICES. WHEN STEEL FRAMING DOES NOT PERMIT INSTALLATION OF HANGER WIRES AT SPACING REQUIRED, INSTALL CARRYING CHANNELS OR OTHER SUPPLEMENTAL SUPPORT FOR ATTACHMENT OF HANGER WIRES. E. DO NOT SUPPORT CEILINGS DIRECTLY FROM PERMANENT METAL FORMS OR FLOOR DECK; ANCHOR INTO CONCRETE SLABS. F. DO NOT ATTACH HANGERS TO STEEL DECK TABS OR TO STEEL ROOF DECK. G. INSTALL EDGE MOLDINGS AND TRIM OF TYPE INDICATED AT PERIMETER OF ACOUSTICAL CEILING AREA AND WHERE NECESSARY TO CONCEAL EDGES OF ACOUSTICAL PANELS. SCREW ATTACH MOLDINGS TO SUBSTRATE AT INTERVALS NOT MORE THAN 16 INCHES (400 MM) O.C. AND NOT MORE THAN 3 INCHES (75 MM) FROM ENDS, LEVELING WITH CEILING SUSPENSION SYSTEM TO A TOLERANCE OF 1/8 INCH IN 12 FEET (3.2 MM IN 3.6 M). MITER CORNERS ACCURATELY AND CONNECT SECURELY. H. INSTALL SUSPENSION SYSTEM RUNNERS SO THEY ARE SQUARE AND SECURELY INTERLOCKED WITH ONE ANOTHER. REMOVE AND REPLACE DENTED, BENT, OR KINKED MEMBERS. I. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW AND ACCORDING TO ASTM C 840: LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW UNLESS OTHERWISE INDICATED. REFER TO INTERIOR FINISH DRAWINGS FOR GYPSUM BOARD BULKHEAD FINISH DETAILS. J. REFER TO ELECTRICAL PLAN AND PLUMBING PLAN FOR GENERAL NOTES. K. ALL LAY-IN ACOUSTICAL CEILING TILE SHALL BE INSTALLED TO MATCH THE EXISTING ACOUSTIC PANEL CEILING AND GYP. BD. CEILINGS UNLESS NOTED OTHERWISE. GENERAL DEMOLITION NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. DEFINITIONS • REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFF-SITE UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED. • REMOVE AND SALVAGE: CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. • REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED. • EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE PERMANENTLY REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, REMOVED AND SALVAGED, OR REMOVED AND REINSTALLED. A. CONDITIONS EXISTING AT TIME OF INSPECTION FOR BIDDING PURPOSE WILL BE MAINTAINED BY OWNER AS FAR AS PRACTICAL. B. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION. C. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE IS NOT PERMITTED. D. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. E. MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING SELECTIVE DEMOLITION OPERATIONS. F. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND AS INDICATED IN DIVISION 2 SECTION "SELECTIVE STRUCTURE DEMOLITION". G. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS AND TRANSPORT ITEMS TO STORAGE AREA DESIGNATED BY OWNER. H. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED. I. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. J. DISPOSAL OF DEMOLISHED MATERIALS: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS. COMPLY WITH REQUIREMENTS SPECIFIED IN DIVISION 01 SECTION "CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL." K. DO NOT BURN DEMOLISHED MATERIALS. L. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY DISPOSE OF THEM. M. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN. N. RELOCATE/REMOVE EXISTING ELECTRICAL DEVICES IN EXISTING WALLS AS REQUIRED TO MATCH NEW ELECTRICAL PLANS. O. REMOVE SIGNAGE IN SUITES WITHIN THE PROJECT SCOPE. RETURN TO OWNER AS NEEDED. P. REMOVE GYPSUM BOARD AS REQUIRED IN EXISTING WALLS RECEIVING NEW ELECTRICAL, MECHANICAL, PLUMBING FIXTURES/DEVICES. Q. REMOVE GYPSUM BOARD, VAPOR BARRIER AND ALL DAMAGED INSULATION ON INTERIOR FACE OF EXTERIOR WALLS AS NEEDED. R. PROVIDE APPROPRIATE DUST PARTITION AND CONTRACTOR ACCESS DOOR TO ISOLATE CONSTRUCTION AREA. GENERAL CASEWORK NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ADA, AMERICANS WITH DISABILITIES ACT REQUIREMENTS: THE FOLLOWING SPECIAL REQUIREMENTS SHALL BE MET, WHERE SPECIFICALLY INDICATED ON ARCHITECTURAL PLANS AS "ADA", OR BY GENERAL NOTE. B. COUNTERTOP HEIGHT: WITH OR WITHOUT CABINET BELOW, NOT TO EXCEED A HEIGHT OF 36 INCHES (864 MM) A.F.F., (ABOVE FINISHED FLOOR), AT A SURFACE DEPTH OF 24 INCHES (610 MM). C. KNEESPACE CLEARANCE: SHALL BE MINIMUM 29 INCHES (737 MM) A.F.F. AT APRON, AND 30 INCHES (762 MM) CLEAR SPAN WIDTH. D. 12 INCH (305 MM) DEEP SHELVING, ADJUSTABLE OR FIXED: NOT TO EXCEED A RANGE FROM 9 INCHES (229 MM) A.F.F. TO 54 INCHES (1372 MM) A.F.F. E. METAL FRAME AND METAL BACKING STRAP: FASTEN WALL CABINETS THROUGH BACK, NEAR TOP AND BOTTOM, AT ENDS AND NOT LESS THAN 24 INCHES (600 MM) O.C., WITH TOGGLE BOLTS THROUGH METAL BACKING BEHIND GYPSUM BOARD. F. FASTEN PLASTIC-LAMINATE COUNTERTOPS BY SCREWING THROUGH CORNER BLOCKS OF BASE UNITS INTO UNDERSIDE OF COUNTERTOP. FORM SEAMS USING SPLINES TO ALIGN ADJACENT SURFACES, AND SECURE WITH GLUE AND CONCEALED CLAMPING DEVICES DESIGNED FOR THIS PURPOSE. G. ADJUST EXISTING CABINETS AND HARDWARE SO DOORS AND DRAWERS ARE CENTERED IN OPENINGS AND OPERATE SMOOTHLY WITHOUT WARP OR BIND. LUBRICATE OPERATING HARDWARE AS RECOMMENDED BY MANUFACTURER. H. CLEAN ALL SURFACES OF CASEWORK PRIOR TO SUBSTANTIAL COMPLETION. I. ON ALL PLASTIC LAMINATE COUNTERTOPS PROVIDE 3mm PVC EDGE ON EXPOSED EDGES TO MATCH LAMINATE, RADIUS EDGE ON ALL EXPOSED CORNERS AND 4" TALL APPLIED SIDE AND BACKSPLASHES WHERE SHOWN IN ELEVATIONS. J. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK. REFER TO INTERIOR FINISH PLAN AND INTERIOR ELEVATIONS FOR MATERIAL SELECTIONS. K. COORDINATE BULKHEAD HEIGHTS INDICATED ON INTERIOR ELEVATIONS WITH THAT SHOWN ON THE REFLECTED CEILING PLAN. GENERAL INTERIOR ELEVATION NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. PROVIDE METAL COUNTERTOP BRACKETS AT 32" O.C. MAX. PROVIDE IN-WALL BLOCKING AS REQUIRED. BRACKETS TO MATCH WALL PAINT COLOR. B. PROVIDE 2 1/2" GROMMETS IN WORKSURFACES WHERE POWER/DATA RECEPTACLES ARE BELOW COUNTER. COORDINATE FINAL GROMMET LOCATION WITH OWNER PRIOR TO INSTALLATION. C. EQUIPMENT NUMBERS IN ELEVATION REFERENCE THE EQUIPMENT SCHEDULE. GENERAL PROJECT NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES. B. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. C. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. D. THE GENERAL CONTRACTOR SHALL COORDINATE AN APPROPRIATE DUMPSTER LOCATION WITH THE LANDLORD. E. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. F. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB CLEANLINESS. G. THE CONTRACTOR(S) IS TO PROVIDE A COMPLETE, FINISHED AND FUNCTIONAL INSTALLATION OF ALL COMPONENTS DESCRIBED IN THESE DRAWINGS. H. THE GENERAL CONTRACTOR SHALL LABEL ALL RATED WALLS ABOVE CEILING. I. ALL AREAS OF DEPICTED WORK EXIST IN A BUILDING THAT IS CURRENTLY OCCUPIED. THE CONTRACTOR SHALL COORDINATE WORK, TIME AND ACCESS WITH ST. VINCENT HEALTH AND/OR MEDXCEL'S PROPERTY MANAGER AND STRIVE TO ENSURE THEIR WORK IN NO WAY ADVERSELY AFFECTS THE ADJACENT OCCUPIED SPACES. J. THE ARCHITECT HAS MADE HIS BEST EFFORTS TO COMPLY WITH THE AMERICAN WITH DISABILITIES ACT (ADA). IF ANY PORTION OF THIS WORK IS FOUND TO BE IN CONFLICT WITH ADA COMPLIANCE, THE ARCHITECT SHALL BE NOTIFIED, IN WRITING, BY THE CONTRACTOR IMMEDIATELY. K. WARRANT TO THE OWNER THAT ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW. UNLESS NOTED OTHERWISE SPECIFIED, AND THAT ALL WORK SHALL BE OF GOOD QUALITY, FREE FROM DEFECTS AND FAULTS, AND CONFORMS TO THE CONTRACT DOCUMENTS. L. ALL MECHANICAL, PLUMBING AND ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. M. VERIFY WITH TENANT AND LANDLORD ALL BUILDING STANDARD MATERIALS AND SYSTEMS. SYMBOL LEGEND X WALL TYPE ELEVATION TAG DETAIL TAG SECTION DETAIL TAG WINDOW/LOUVER AND FRAME TAG FLOOR PLAN NOTE TAG REFLECTED CEILING PLAN NOTE TAG DEMOLITION PLAN NOTE TAG DOOR NUMBER TAG CEILING/BULKHEAD TAG WALL TO BE DEMOLISHED WALL TO REMAIN/NEW WALLS DOOR AND FRAME TO BE REMOVED INTERIOR ELEVATION NOTE TAG XXXXX XX MIN RV X XX 1 TOILET ACCESSORY TAG - REFER TO SPECIFICATIONS TA-XX X'-X" 1 1 REVISION TAG ROOM TAG XX XXXX X A101 1 SIM XX XXXX UNIT - EXTERIOR/INTERIOR ELEVATION TAG NORTH ARROW View Name 1 1/16" = 1'-0" REFERENCE: 1 / AF101 DRAWING TITLE RATING REMARKS/VOLTAGE HARDWARE SET DOOR TYPE DATUM POINT 1 CASEWORK/EQUIPMEN T TAG 0 COLUMN GRID DESIGNATION 1 1 1 CEILING TYPE CEILING HEIGHT XX XXXX X XXXX INDICATES SIMILAR DETAIL REFERENCING VIEW SCALE XXX ROOM KEY NOTE (OFFICE USE ONLY) SPECIFICATION SECTION 00 00 00 . A1 TEXT NOTATION MATERIAL LEGEND CONCRETE MASONRY UNIT FACE BRICK CONCRETE EARTH METAL/STEEL PLYWOOD FINISHED WOOD WOOD BLOCKING RIGID INSULATION INSULATION - BATT/LOOSE GYPSUM BOARD WOOD SHIM CONTRACTORS TO PROCURE PRODUCTS LISTED ABOVE FROM ASCENSION'S NATIONAL ACCOUNT THROUGH GRAINGER 07 84 00 FIRESTOPPING STI (SPECIFIED TECHNOLOGIES INC.) DIVISION MATERIAL APPROVED MANUFACTURER 08 12 13 H.M. FRAMES & DOORS CECO DOOR 08 14 16 FLUSH WOOD DOORS ASSA ABLOY 08 71 00 DOOR HARDWARE ASSA ABLOY 09 51 13 ACOUSTICAL PANEL CEILINGS ARMSTRONG 09 91 23 INTERIOR PAINT PRATT & LAMBERT 10 26 00 WALL AND CORNER GUARDS IN-PRO WALL PROTECTION 26 51 00 INTERIOR LIGHTING ACUITY BRANDS AND LITHONIA DIVISION MATERIAL APPROVED MANUFACTURER 12 05 00 CUBICLE CURTAINS IN-PRO 22 40 00 PLUMBING FIXTURES AMERICAN STANDARD, CHICAGO FAUCETS, DELTA AND SLOAN 26 27 26 WIRING DEVICES BRYANT-HUBBELL PRODUCT PROCUREMENT MATRIX SHOULD A CONTRACTOR CONSIDER PURCHASING THESE MATERIALS THROUGH OTHER SOURCES, THE CONTRACTOR IS TO PROVIDE THE ARCHITECT WITH THE PURCHASE COST FROM GRAINGER AND THE PURCHASE COST FROM THE OTHER SOURCES FOR EVALUATION arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:45 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A001 ARCHITECTURAL GENERAL NOTES 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102 SUBMITTAL LIST SPEC SECTION SPEC ITEM SUBMITTAL 08 12 13 METAL DOOR FRAMES SHOP DRAWINGS 08 12 13 METAL DOOR FRAMES DIGITAL IMAGE OF SAMPLE 08 71 00 DOOR HARDWARE SHOP DRAWINGS 09 51 13 ACOUSTICAL PANEL CEILING DIGITAL IMAGE OF SAMPLE 09 65 00 RESILIENT FLOORING DIGITAL IMAGE OF SAMPLE 09 65 13 RESILIENT BASE DIGITAL IMAGE OF SAMPLE 09 68 00 CARPET DIGITAL IMAGE OF SAMPLE 09 91 23 PAINT DRAW DOWN SAMPLE 10 28 00 TOILET ACCESSORIES CUT SHEETS 12 35 30 CASEWORK SHOP DRAWINGS 12 36 23 PLASTIC LAMINATE COUNTERTOPS DIGITAL IMAGE OF SAMPLE 12 36 61 SOLID SURFACE COUNTERTOPS DIGITAL IMAGE OF SAMPLE 23 00 00 PLUMBING FIXTURES CUT SHEETS 26 00 00 LIGHTING FIXTURES CUT SHEETS