HomeMy WebLinkAboutA002 TYPESSQUARE-EDGE VINYL-FACED
ACOUSTICAL CEILING
PANELS.
15/16" ACOUSTICAL PANEL
CEILING SUSPENSION GRID
(WHITE).
ACOUSTICAL PANEL CEILING
SUSPENSION WIRE. DO NOT
ATTACH TO DECK.
APC-1
2x2 Grid System
5/8" GB TYPICAL
3 5/8" 20 GA. METAL STUD
FRAMING @ 16" O.C.
CORNER BEAD
FINISH, TYPICAL
5/8" GB. TO RECEIVE (P1)
CEILING ELEVATION
CALLOUTS ARE TO THE
GB-1 BOTTOM OF GB
KICKER BRACING TO
STRUCTURE ABOVE AT 48"
O.C. MAX.
A P C -
CEILING TYPE
GB = GYPSUM BOARD
APC = ACOUSTICAL PANEL CEILING
DPC = DECORATIVE PANEL CEILING
DCG= DECORATIVE CEILING GRID
CEILING TYPE MODIFIER
SEE DRAWINGS
CEILING NAMING
CONVENTION
1
S 4. 1 A
SUBSTRATE / FRAME /
BACKUP
S = STEEL STUD
W = WOOD STUD
M = MASONRY (CMU)
F = FURRING (STEEL U.N.O.)
I = METAL-FACED RIGID
INSULATION
H = SHAFT WALL (STEEL
U.N.O.)
NOMINAL SUBSTRATE
WIDTH
(REFER TO WALL TYPE
FOR SUBSTRATE
WIDTH)
WALL EXTENTS MODIFIER (OPTIONAL)
(REFER TO WALL TYPES FOR ADDITIONAL
INFORMATION)
WALL CHARACTERISTIC MODIFIER (OPTIONAL)
a = 1 HR FIRE
b = 2 HR FIRE
c = 3 HR FIRE
d = 4 HR FIRE
s = SMOKE RESISTIVE
i = INSULATIVE
WALL NAMING
CONVENTION
A
INTERIOR WALL TYPES NOTES
REFER TO THE GENERAL NOTES ON SHEET A001 FOR ADDITIONAL REQUIREMENTS.
A. WHERE INSULATION IS PRESENT WITHIN STUD CAVITY, AT INTERIOR WALLS, AND GYPSUM
BOARD IS NOT PRESENT, PROVIDE "CHICKEN WIRE" TO SECURE INSULATION WITHIN THE STUD
CAVITY.
B. ALL WALL TYPES ARE TO BE TYPE 'S4' UNLESS NOTED OTHERWISE.
C. ALL GYPSUM BOARD (GB) IS TYPE X UNLESS NOTED OTHERWISE.
D. BOTTOM EDGE OF GYPSUM BOARD SHALL BE HELD ABOVE THE SLAB / SUBFLOOR A MINIMUM
OF 1/2".
E. IN A ROOM THAT DOES NOT HAVE A CEILING, THE GYPSUM BOARD SHALL EXTEND TO THE
DECK ABOVE ON THE SIDE OF THE WALL WHERE THE CEILING IS NOT PRESENT.
F. ALL WALLS GOING TO DECK TO HAVE MOLD AND MOISTURE RESISTANT GYPSUM BOARD FROM
6" ABOVE CEILING LINE TO DECK.
G. AT ALL WALLS SCHEDULED TO RECEIVE CERAMIC TILE, CONTRACTOR SHALL SUBSTITUTE
GLASS MAT INTERIOR GYPSUM WALLBOARD FOR THE STANDARD GYPSUM WALLBOARD
IDENTIFIED IN THE WALL TYPES. REFER TO ROOM FINISH SCHEDULE FOR LOCATIONS OF
CERAMIC TILE.
H. PROVIDE 4'-0" WIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD CENTERED BEHIND ALL
PLUMBING FIXTURES.
I. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON ALL WALLS INTERSECTING
EXTERIOR WALLS FOR THE FIRST 4'-0" OF THE WALL ADJACENT TO THE EXTERIOR WALL.
J. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON WALLS OF MECHANICAL
ROOMS, ELECTRICAL CLOSETS, TOILET ROOMS AND HOUSEKEEPING ROOMS.
K. ANY PATCHING AND REPAIRING TO EXTERIOR WALL GYPSUM BOARD TO BE DONE WITH MOLD
AND MOISTURE RESISTANT GYPSUM BOARD.
L. ALL FRAMING SHALL BE 20 GUAGE UNLESS NOTED OTHERWISE.
M. IN NONRATED WALLS WITH GYPSUM BOARD TO DECK SEAL ALL JOINTS AND PENETRATIONS
WITH TAPE, JOINT COMPOUND, SEALANT TO SEAL ALL GAPS.
N. PROVIDE REINFORCED CORNER FRAMING AT ALL EXPOSED CORNERS AND END WALLS.
REFER TO DETAIL.
O. REPAIRS TO EXISTING RATED WALLS MUST BE REPAIRED TO MATCH RATING REQUIREMENTS.
INTERIOR CEILING TYPES NOTES
REFER TO THE GENERAL NOTES ON SHEET A-001 FOR ADDITIONAL REQUIREMENTS.
A. REFER TO CEILING PLANS FOR CEILING LOCATIONS.
B. METAL STUD FRAMING IN LIEU OF WOOD STUD FRAMING.
C. ALL NEW ACOUSTIC PANEL CEILING TILE AND SUSPENDED GRID SYSTEM TO MATCH
EXISTING.
D. ALL GYP. BD. BULKHEAD BOTTOM FACE OF GYP. BD. TO RECEIVE (PT4).
CONTINUOUS DEFLECTION TRACK ANCHORED TO
EXISTING FLOOR SLAB/STRUCTURE ABOVE
ROOF/CEILING TRUSS/STRUCTURE
PROVIDE "ZIP-STRIP" TRIM AT TOP EDGE OF
GYPSUM BOARD AT FINISHED CEILINGS.
WALL BASE. REFER TO ROOM FINISH SCHEDULE
REFER TO ROOM FINISH SCHEDULE FOR
FLOOR FINISH.
FLOOR CONSTRUCTION VARIES - SEE PLANS
CONTINUOUS METAL STUD TRACK
ANCHORED TO EXISTING FLOOR
METAL STUD FRAMING
5/8" TYPE X GYPSUM BOARD U.N.O.
1/2"
HEAD
PLAN
BASE
'S4.2i'
SOUND BATTS (SAB) WHERE INDICATED.
ACOUSTIC SEALANT AT INSULATIVE WALLS.
FIRE-RESISTIVE JOINT SYSTEM AS REQUIRED
TO MAINTAING RATING INDICATED, AT
JUNCTURE OF GYPSUM BOARD AND
FLOOR/CEILING ASSEMBLY.
FIRE-RESISTIVE JOINT SYSTEM AT ALL GB
PENETRATIONS IN RATED WALLS
CONTINUOUS FIRE-RESITIVE JOINT SYSTEM AS
REQUIRED BY RATING INDICATED AND DECK
ORIENTATION
CONTINUOUS DEFLECTION TRACK ANCHORED TO
EXISTING FLOOR SLAB/STRUCTURE ABOVE
ROOF/CEILING TRUSS/STRUCTURE
CONTINUOUS SEALANT BEAD AT JUNCTURE OF
GYPSUM BOARD AND FLOOR/CEILING ASSEMBLY
WALL BASE. REFER TO ROOM FINISH SCHEDULE
REFER TO ROOM FINISH
SCHEDULE FOR FLOOR FINISH.
FLOOR CONSTRUCTION VARIES - SEE PLANS
CONTINUOUS METAL STUD TRACK
ANCHORED TO FLOOR
METAL STUD FRAMING
5/8" TYPE X GYPSUM BOARD U.N.O.
HEAD
PLAN
BASE
'Sx.1'
1/2"
SOUND BATTS (SAB) WHERE INDICATED.
ACOUSTIC SEALANT AT INSULATIVE WALLS.
HARD LID ABOVE
LID
WALL BASE. REFER TO ROOM FINISH
SCHEDULE
REFER TO ROOM FINISH SCHEDULE
FOR FLOOR FINISH.
FLOOR CONSTRUCTION
VARIES - SEE PLANS
CONTINUOUS METAL STUD TRACK
ANCHORED TO EXISTING FLOOR
METAL STUD FRAMING.
5/8" TYPE X GYPSUM BOARD U.N.O
1/2"
'S4'
U.N.O.
6"
KICKER BRACING TO
STRUCTURE ABOVE AT 48" O.C.
MAX.
HEAD
PLAN
BASE
SOUND BATTS (SAB) WHERE INDICATED.
ACOUSTIC SEALANT AT INSULATIVE WALLS.
2'-0" WIDE (SAB) AT INSULATIVE WALLS.
arcDESIGN Project Number:
Date:
Drawing Title:
Drawing Number:
Revisions:
Drawn By:
Client Project Number:
201 N. Delaware Street, Suite B
Indianapolis, IN 46204
317.951.9192 T | 317.951.9194 F
www.arcdesign.us
This drawing and its contents are the property
of arcDESIGN P.C., and shall not be
reproduced in whole or in part by any means,
mechanical or electronic, without express
written permission of arcDESIGN.
2/20/2018 12:49:46 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt
ST. VINCENT MEDICAL GROUP
A002
TYPES
17124
02.20.2018
100% CD'S
30102 - CARMEL PLASTIC SURGERY
13450 N. MERIDIAN, SUITE 140
CARMEL, IN 46032
JBL
30102