Loading...
HomeMy WebLinkAboutA002 TYPESSQUARE-EDGE VINYL-FACED ACOUSTICAL CEILING PANELS. 15/16" ACOUSTICAL PANEL CEILING SUSPENSION GRID (WHITE). ACOUSTICAL PANEL CEILING SUSPENSION WIRE. DO NOT ATTACH TO DECK. APC-1 2x2 Grid System 5/8" GB TYPICAL 3 5/8" 20 GA. METAL STUD FRAMING @ 16" O.C. CORNER BEAD FINISH, TYPICAL 5/8" GB. TO RECEIVE (P1) CEILING ELEVATION CALLOUTS ARE TO THE GB-1 BOTTOM OF GB KICKER BRACING TO STRUCTURE ABOVE AT 48" O.C. MAX. A P C - CEILING TYPE GB = GYPSUM BOARD APC = ACOUSTICAL PANEL CEILING DPC = DECORATIVE PANEL CEILING DCG= DECORATIVE CEILING GRID CEILING TYPE MODIFIER SEE DRAWINGS CEILING NAMING CONVENTION 1 S 4. 1 A SUBSTRATE / FRAME / BACKUP S = STEEL STUD W = WOOD STUD M = MASONRY (CMU) F = FURRING (STEEL U.N.O.) I = METAL-FACED RIGID INSULATION H = SHAFT WALL (STEEL U.N.O.) NOMINAL SUBSTRATE WIDTH (REFER TO WALL TYPE FOR SUBSTRATE WIDTH) WALL EXTENTS MODIFIER (OPTIONAL) (REFER TO WALL TYPES FOR ADDITIONAL INFORMATION) WALL CHARACTERISTIC MODIFIER (OPTIONAL) a = 1 HR FIRE b = 2 HR FIRE c = 3 HR FIRE d = 4 HR FIRE s = SMOKE RESISTIVE i = INSULATIVE WALL NAMING CONVENTION A INTERIOR WALL TYPES NOTES REFER TO THE GENERAL NOTES ON SHEET A001 FOR ADDITIONAL REQUIREMENTS. A. WHERE INSULATION IS PRESENT WITHIN STUD CAVITY, AT INTERIOR WALLS, AND GYPSUM BOARD IS NOT PRESENT, PROVIDE "CHICKEN WIRE" TO SECURE INSULATION WITHIN THE STUD CAVITY. B. ALL WALL TYPES ARE TO BE TYPE 'S4' UNLESS NOTED OTHERWISE. C. ALL GYPSUM BOARD (GB) IS TYPE X UNLESS NOTED OTHERWISE. D. BOTTOM EDGE OF GYPSUM BOARD SHALL BE HELD ABOVE THE SLAB / SUBFLOOR A MINIMUM OF 1/2". E. IN A ROOM THAT DOES NOT HAVE A CEILING, THE GYPSUM BOARD SHALL EXTEND TO THE DECK ABOVE ON THE SIDE OF THE WALL WHERE THE CEILING IS NOT PRESENT. F. ALL WALLS GOING TO DECK TO HAVE MOLD AND MOISTURE RESISTANT GYPSUM BOARD FROM 6" ABOVE CEILING LINE TO DECK. G. AT ALL WALLS SCHEDULED TO RECEIVE CERAMIC TILE, CONTRACTOR SHALL SUBSTITUTE GLASS MAT INTERIOR GYPSUM WALLBOARD FOR THE STANDARD GYPSUM WALLBOARD IDENTIFIED IN THE WALL TYPES. REFER TO ROOM FINISH SCHEDULE FOR LOCATIONS OF CERAMIC TILE. H. PROVIDE 4'-0" WIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD CENTERED BEHIND ALL PLUMBING FIXTURES. I. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON ALL WALLS INTERSECTING EXTERIOR WALLS FOR THE FIRST 4'-0" OF THE WALL ADJACENT TO THE EXTERIOR WALL. J. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON WALLS OF MECHANICAL ROOMS, ELECTRICAL CLOSETS, TOILET ROOMS AND HOUSEKEEPING ROOMS. K. ANY PATCHING AND REPAIRING TO EXTERIOR WALL GYPSUM BOARD TO BE DONE WITH MOLD AND MOISTURE RESISTANT GYPSUM BOARD. L. ALL FRAMING SHALL BE 20 GUAGE UNLESS NOTED OTHERWISE. M. IN NONRATED WALLS WITH GYPSUM BOARD TO DECK SEAL ALL JOINTS AND PENETRATIONS WITH TAPE, JOINT COMPOUND, SEALANT TO SEAL ALL GAPS. N. PROVIDE REINFORCED CORNER FRAMING AT ALL EXPOSED CORNERS AND END WALLS. REFER TO DETAIL. O. REPAIRS TO EXISTING RATED WALLS MUST BE REPAIRED TO MATCH RATING REQUIREMENTS. INTERIOR CEILING TYPES NOTES REFER TO THE GENERAL NOTES ON SHEET A-001 FOR ADDITIONAL REQUIREMENTS. A. REFER TO CEILING PLANS FOR CEILING LOCATIONS. B. METAL STUD FRAMING IN LIEU OF WOOD STUD FRAMING. C. ALL NEW ACOUSTIC PANEL CEILING TILE AND SUSPENDED GRID SYSTEM TO MATCH EXISTING. D. ALL GYP. BD. BULKHEAD BOTTOM FACE OF GYP. BD. TO RECEIVE (PT4). CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLOOR SLAB/STRUCTURE ABOVE ROOF/CEILING TRUSS/STRUCTURE PROVIDE "ZIP-STRIP" TRIM AT TOP EDGE OF GYPSUM BOARD AT FINISHED CEILINGS. WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES - SEE PLANS CONTINUOUS METAL STUD TRACK ANCHORED TO EXISTING FLOOR METAL STUD FRAMING 5/8" TYPE X GYPSUM BOARD U.N.O. 1/2" HEAD PLAN BASE 'S4.2i' SOUND BATTS (SAB) WHERE INDICATED. ACOUSTIC SEALANT AT INSULATIVE WALLS. FIRE-RESISTIVE JOINT SYSTEM AS REQUIRED TO MAINTAING RATING INDICATED, AT JUNCTURE OF GYPSUM BOARD AND FLOOR/CEILING ASSEMBLY. FIRE-RESISTIVE JOINT SYSTEM AT ALL GB PENETRATIONS IN RATED WALLS CONTINUOUS FIRE-RESITIVE JOINT SYSTEM AS REQUIRED BY RATING INDICATED AND DECK ORIENTATION CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLOOR SLAB/STRUCTURE ABOVE ROOF/CEILING TRUSS/STRUCTURE CONTINUOUS SEALANT BEAD AT JUNCTURE OF GYPSUM BOARD AND FLOOR/CEILING ASSEMBLY WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES - SEE PLANS CONTINUOUS METAL STUD TRACK ANCHORED TO FLOOR METAL STUD FRAMING 5/8" TYPE X GYPSUM BOARD U.N.O. HEAD PLAN BASE 'Sx.1' 1/2" SOUND BATTS (SAB) WHERE INDICATED. ACOUSTIC SEALANT AT INSULATIVE WALLS. HARD LID ABOVE LID WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES - SEE PLANS CONTINUOUS METAL STUD TRACK ANCHORED TO EXISTING FLOOR METAL STUD FRAMING. 5/8" TYPE X GYPSUM BOARD U.N.O 1/2" 'S4' U.N.O. 6" KICKER BRACING TO STRUCTURE ABOVE AT 48" O.C. MAX. HEAD PLAN BASE SOUND BATTS (SAB) WHERE INDICATED. ACOUSTIC SEALANT AT INSULATIVE WALLS. 2'-0" WIDE (SAB) AT INSULATIVE WALLS. arcDESIGN Project Number: Date: Drawing Title: Drawing Number: Revisions: Drawn By: Client Project Number: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 2/20/2018 12:49:46 PM C:\Users\jlillibridge\Documents\Revit 2017 Local\Dr.Paul Plastic Surgery-Suite 140_aD17_jlillibridgeVYYUA.rvt ST. VINCENT MEDICAL GROUP A002 TYPES 17124 02.20.2018 100% CD'S 30102 - CARMEL PLASTIC SURGERY 13450 N. MERIDIAN, SUITE 140 CARMEL, IN 46032 JBL 30102