HomeMy WebLinkAboutA 1.1 ArchitecturalCOMMON
SUITE 100
38'-10" x 76'-5"
SUITE 101
38'-10" x 76'-5"
PROGRAMMING
DESKS
15'-10" x 32'-1"
QC DESKS
17'-3" x 16'-0"
OFFICE
9'-0" x 12'-0" OFFICE
8'-6" x 12'-0"
OFFICE
12'-7" x 9'-8"
OFFICE
11'-3" x 9'-8"
KITCHEN
14'-4" x 15'-8"
OFFICE
10'-3" x 10'-0"
OFFICE
13'-10" x 10'-0"
RECEPTION
23'-10" x 14'-5"
OFFICE
9'-8" x 14'-4"
OFFICE
9'-11" x 16'-0"
OFFICE
9'-7" x 16'-0"
OFFICE
OFFICE 17'-7" x 10'-0"
10'-3" x 10'-0"
HALLWAY
17'-10" x 26'-0"
OFFICE
10'-10" x 11'-8"
OFFICE
12'-2" x 11'-8"
OFFICE
9'-4" x 16'-1"
OFFICE
10'-3" x 15'-8"
HALLWAY
28'-7" x 16'-11"
OFFICE
13'-10" x 10'-0"
OPEN
18'-8" x 23'-7"
CONFERENCE
ROOM
9'-11" x 16'-1"
TRAINING
ROOM
24'-2" x 26'-5"
GENERAL NOTES
B. THE ERRORS AND OMISSIONS DESIGN LIABILITY FOR THE PROJECT SHALL BE LIMITED TO THE DESIGN COST OF CORRECTING
THE DEFICIENCY.
DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, FIRE PROTECTIVE
DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREE OF DEBRIS. MATERIALS
STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE STORED IN A LOCATION APPROVED BY THE
OWNER.
Q.
P.
CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE WORK IN THESE DOCUMENTS,
UNLESS CLEARLY NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING WORK ADJACENT TO OR IN THE AREA OF NEW WORK SHALL
BE PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE
REMOVED OR ALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES, BASE, AND TRIM
WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE TO EXISTING WORK AND RESTORE TO
ORIGINAL CONDITION.
O.
ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS, PREMIUM
GRADE.
M.
N.
PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT.
L.
NEW FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR PARTITIONS, UNLESS
NOTED OTHERWISE.
K.
PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES.
J.
ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS,
AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE
CODES, THE AMERICANS WITH DISABILITIES ACT (ADA), AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND
REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.
ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE
VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCALE DIMENSIONS ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE
FACE OF GYPSUM BOARD, MASONRY/CONCRETE WALLS, OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.
CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THE SUBMITTAL HAS BEEN REVIEWED,
APPROVED, AND THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.
I.
H.
G.
F.
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL LOCAL PERMITS REQUIRED FOR COMPLETION OF THIS PROJECT.
ALL WORK IS TO BE COORDINATED WITH THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION,
AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER'S F.F.E.
E.
THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO THE START OF WORK.
REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY.
C.
D.
A.
EXISTING FIRE SPRINKLER WILL REMAIN AND 2 WALL MOUNTED FIRE EXTINGUISHERS WILL BE PLACED ONE AT EACH ENTRANCE.
TEMPORARY PARTITIONS AND TEMPORARY DOORS AS INDICATED ON THIS PLAN, OR AS DEEMED NECESSARY BY THE ARCHITECT
AND OWNER, SHALL BE PROVIDED. THEY SHALL BE MAINTAINED, WITH ANY DAMAGE REPAIRED IMMEDIATELY, TO AVOID
MIGRATION OF DUST INTO THE ADJOINING AREAS.
WALL TYPE LEGEND
WT1
EXISTING WALL CONSTRUCTION
TO REMAIN
N
S
W E
NEW WALL CONSTRUCTION: 25GA - 3 5/8" METAL STUDS
@ 16" O.C. TERMINATED AT 13' ABOVE THE FINISHED
FLOOR. FASTEN 5/8" DRYWALL SHEATHING TO BOTH SIDES
OF METAL STUDS WITH METAL SCREW FASTENERS FOR
DRYWALL ON METAL STUD CONSTRUCTION.
BUILD NEW WALLS AS SHOWN ON FLOOR PLAN. SEE WALL TYPE DESCRIPTIONS.
ADA & ACCESSIBILITY INFORMATION
DOOR SPACE - THE FLOOR ON EACH SIDE OF A DOORWAY IS REQUIRED TO BE LEVEL AND CLEAR FOR A MINIMUM DEPTH OF
60 INCHES ON THE SWING SIDE, MEASURED AT RIGHT ANGLES TO THE OPENING, AND FOR 48 INCHES ON THE SIDE AWAY
FROM THE DOOR. ON THE SWING SIDE OF THE DOOR, THE LEVEL AND CLEAR AREA IS REQUIRED TO EXTEND FOR 24 INCHES
ON THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOOR, AND TO EXTEND FOR 18 INCHES FOR INTERIOR DOORS. A LEVEL
AREA IS DEFINED AS A SURFACE WHICH DOES NOT SLOPE MORE THAN
1
4 INCH IN 1 FOOT IN ANY DIRECTION.
PROTRUDING OBJECTS - [24 CAC, SECTION 2-1721] ACCESSORIES. WHERE TOWEL, SANITARY NAPKIN AND RECEPTACLES
AND SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE IS TO BE LOCATED WITH ALL
OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40 INCHES FROM THE FLOOR. MOUNT MIRROR WITH THE BOTTOM EDGE
NO MORE THAN 40 INCHES FROM THE FLOOR. LOCATE TOILET TISSUE DISPENSER ON THE WALL WITHIN 12 INCHES OF THE
FRONT EDGE OF THE TOILET SEAT.
FLOOR PLAN
AG
AEM/ SA
R. Safety glazing shall be used for glazing in an individual fixed panel adjacent to a door where the nearest exposed edge of the glazing is
within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than
60 inches above the walking surface. 1/4" clear glazing (IG-1) noted needs to be either tempered glass or laminated glass.
S. Safety glazing not required on existing windows and doors.
THE INFORMATION CONTAINED HEREIN IS THE EXCLUSIVE PROPERTY OF
H.C.O., INC., AND IS THEREBY PROTECTED UNDER COPYRIGHT LAWS. THE
ORIGINAL IDEAS REPRESENTED HERE BY THIS INFORMATION SHALL NOT
BE USED, ALTERED, OR REPRODUCED IN ANY MANNER WITHOUT THE
EXPRESSED WRITTEN CONSENT OF H.C.O., INC.
SHEET NO:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE:
REVISIONS:
CONSTRUCTION DOCUMENTS
COMPASS
RESIDENTIAL
OFFICE LAYOUT
9660 COMMERCE DR SUITE 100 & 101
CARMEL, INDIANA 46032
02.09.2018
P:\AE INTERIOR DESIGN\PROJECTS\2017-8 J Benzal\Drawings\ARCHITECTURAL\steve's stamp.jpg
AE DESIGNS
INTERIOR DESIGN
(317) 974-9328
Info@
TheAeExperience.com
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1 WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1
WT1