HomeMy WebLinkAboutA 1.2 Reflected Ceiling PlanCOMMON SUITE 100 38'-10" x 76'-5" SUITE 101 38'-10" x 76'-5" PROGRAMMING DESKS 15'-10" x 32'-1" QC DESKS 17'-3" x 16'-0" OFFICE 9'-0" x 12'-0" OFFICE 8'-6" x 12'-0" OFFICE 12'-7" x 9'-8" OFFICE 11'-3" x 9'-8" KITCHEN 14'-4" x 15'-8" OFFICE 10'-3" x 10'-0" OFFICE 13'-10" x 10'-0" RECEPTION 23'-10" x 14'-5" OFFICE 9'-8" x 14'-4" OFFICE 9'-11" x 16'-0" OFFICE 9'-7" x 16'-0" OFFICE OFFICE 17'-7" x 10'-0" 10'-3" x 10'-0" HALLWAY 17'-10" x 26'-0" OFFICE 10'-10" x 11'-8" OFFICE 12'-2" x 11'-8" OFFICE 9'-4" x 16'-1" OFFICE 10'-3" x 15'-8" HALLWAY 28'-7" x 16'-11" OFFICE 13'-10" x 10'-0" OPEN 18'-8" x 23'-7" CONFERENCE ROOM 9'-11" x 16'-1" TRAINING ROOM 24'-2" x 26'-5" REMOVE EXISTING SWITCHES THAT ARE NOT RE-USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHT FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF ANY WORK. UNLESS NOTED OTHERWISE, CEILING HEIGHT THROUGHOUT THE SPACE IS EXISTING. EXISTING CEILING GRID TO REMAIN AND BE REPAIRED, EXTENDED, AND/ OR MODIFIED AS NEEDED, UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING GRID THAT IS BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 48"AFF AND 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. F. G. D. E. C. B. A. REFLECTED CEILING GENERAL NOTES EXISTING SPRINKLER SYSTEMS AND HEAD LOCATIONS TO REMAIN OR BE RELOCATED AS REQUIRED TO MEET ALL REQUIREMENTS OF THE CURRENT FIRE CODE. LESS THAN 20 HEADS. REFLECTED CEILING LEGEND EXIST: Existing Drywall Ceiling to remain. 1. DROP IN NEW 2X4 CEILING GRID AT 9' AFF. REFLECTED CEILING KEYED NOTES REFLECTED CEILING PLAN AG AEM/ SA PATCH & REPAIR ANY CEILING DAMAGE. THE INFORMATION CONTAINED HEREIN IS THE EXCLUSIVE PROPERTY OF H.C.O., INC., AND IS THEREBY PROTECTED UNDER COPYRIGHT LAWS. THE ORIGINAL IDEAS REPRESENTED HERE BY THIS INFORMATION SHALL NOT BE USED, ALTERED, OR REPRODUCED IN ANY MANNER WITHOUT THE EXPRESSED WRITTEN CONSENT OF H.C.O., INC. SHEET NO: DRAWN BY: CHECKED BY: PROJECT NO: DATE: REVISIONS: CONSTRUCTION DOCUMENTS COMPASS RESIDENTIAL OFFICE LAYOUT 9660 COMMERCE DR SUITE 100 & 101 CARMEL, INDIANA 46032 02.09.2018 P:\AE INTERIOR DESIGN\PROJECTS\2017-8 J Benzal\Drawings\ARCHITECTURAL\steve's stamp.jpg AE DESIGNS INTERIOR DESIGN (317) 974-9328 Info@ TheAeExperience.com 6" RECESSED CAN LIGHTS 10'-0" CEILING HEIGHT 10'-0" CEILING HEIGHT 6" RECESSED CAN LIGHTS 03/16/18 Nick Mishler