HomeMy WebLinkAboutA 1.2 Reflected Ceiling PlanCOMMON
SUITE 100
38'-10" x 76'-5"
SUITE 101
38'-10" x 76'-5"
PROGRAMMING
DESKS
15'-10" x 32'-1"
QC DESKS
17'-3" x 16'-0"
OFFICE
9'-0" x 12'-0" OFFICE
8'-6" x 12'-0"
OFFICE
12'-7" x 9'-8"
OFFICE
11'-3" x 9'-8"
KITCHEN
14'-4" x 15'-8"
OFFICE
10'-3" x 10'-0"
OFFICE
13'-10" x 10'-0"
RECEPTION
23'-10" x 14'-5"
OFFICE
9'-8" x 14'-4"
OFFICE
9'-11" x 16'-0"
OFFICE
9'-7" x 16'-0"
OFFICE
OFFICE 17'-7" x 10'-0"
10'-3" x 10'-0"
HALLWAY
17'-10" x 26'-0"
OFFICE
10'-10" x 11'-8"
OFFICE
12'-2" x 11'-8"
OFFICE
9'-4" x 16'-1"
OFFICE
10'-3" x 15'-8"
HALLWAY
28'-7" x 16'-11"
OFFICE
13'-10" x 10'-0"
OPEN
18'-8" x 23'-7"
CONFERENCE
ROOM
9'-11" x 16'-1"
TRAINING
ROOM
24'-2" x 26'-5"
REMOVE EXISTING SWITCHES THAT ARE NOT RE-USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST
BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH.
THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHT FOR
CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING
HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S ATTENTION
IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF ANY WORK.
UNLESS NOTED OTHERWISE, CEILING HEIGHT THROUGHOUT THE SPACE IS EXISTING.
EXISTING CEILING GRID TO REMAIN AND BE REPAIRED, EXTENDED, AND/ OR MODIFIED AS NEEDED,
UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING GRID THAT
IS BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING.
ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH
48"AFF AND 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
F.
G.
D.
E.
C.
B.
A.
REFLECTED CEILING GENERAL NOTES
EXISTING SPRINKLER SYSTEMS AND HEAD LOCATIONS TO REMAIN OR BE RELOCATED AS REQUIRED TO
MEET ALL REQUIREMENTS OF THE CURRENT FIRE CODE. LESS THAN 20 HEADS.
REFLECTED CEILING LEGEND
EXIST: Existing Drywall Ceiling to remain.
1. DROP IN NEW 2X4 CEILING GRID AT 9' AFF.
REFLECTED CEILING KEYED NOTES
REFLECTED CEILING PLAN
AG
AEM/ SA
PATCH & REPAIR ANY CEILING DAMAGE.
THE INFORMATION CONTAINED HEREIN IS THE EXCLUSIVE PROPERTY OF
H.C.O., INC., AND IS THEREBY PROTECTED UNDER COPYRIGHT LAWS. THE
ORIGINAL IDEAS REPRESENTED HERE BY THIS INFORMATION SHALL NOT
BE USED, ALTERED, OR REPRODUCED IN ANY MANNER WITHOUT THE
EXPRESSED WRITTEN CONSENT OF H.C.O., INC.
SHEET NO:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE:
REVISIONS:
CONSTRUCTION DOCUMENTS
COMPASS
RESIDENTIAL
OFFICE LAYOUT
9660 COMMERCE DR SUITE 100 & 101
CARMEL, INDIANA 46032
02.09.2018
P:\AE INTERIOR DESIGN\PROJECTS\2017-8 J Benzal\Drawings\ARCHITECTURAL\steve's stamp.jpg
AE DESIGNS
INTERIOR DESIGN
(317) 974-9328
Info@
TheAeExperience.com
6" RECESSED CAN LIGHTS
10'-0" CEILING HEIGHT
10'-0" CEILING HEIGHT
6" RECESSED CAN LIGHTS
03/16/18
Nick Mishler