HomeMy WebLinkAboutID 1.2 Finish PlanSUITE 100
38'-10" x 76'-5"
SUITE 101
38'-10" x 76'-5"
PROGRAMMING
DESKS
15'-10" x 32'-1"
QC DESKS
17'-3" x 16'-0"
OFFICE
9'-0" x 12'-0" OFFICE
8'-6" x 12'-0"
OFFICE
12'-7" x 9'-8"
OFFICE
11'-3" x 9'-8"
KITCHEN
14'-4" x 15'-8"
OFFICE
10'-3" x 10'-0"
OFFICE
13'-10" x 10'-0"
COMMON
RECEPTION
23'-10" x 14'-5"
OFFICE
9'-8" x 14'-4"
OFFICE
9'-11" x 16'-0"
OFFICE
9'-7" x 16'-0"
OFFICE
OFFICE 17'-7" x 10'-0"
10'-3" x 10'-0"
HALLWAY
17'-10" x 26'-0"
OFFICE
10'-10" x 11'-8"
OFFICE
12'-2" x 11'-8"
OFFICE
9'-4" x 16'-1"
OFFICE
10'-3" x 15'-8"
HALLWAY
28'-7" x 16'-11"
OFFICE
13'-10" x 10'-0"
OPEN
18'-8" x 23'-7"
CONFERENCE
ROOM
9'-11" x 16'-1"
TRAINING
ROOM
24'-2" x 26'-5"
ALL WOODWORK/MILLWORK SHALL CONFORM TO THE QUALITY STANDARDS OF ARCHITECTURAL WOODWORK INSTITUTE (AWI) PREMIUM GRADE FOR ALL APPLICABLE
SECTIONS. FABRICATOR SHALL BE FAMILIAR WITH AWI STANDARDS.
FABRICATE WOODWORK/MILLWORK ITEMS TO ACTUAL FIELD DIMENSIONS. CONTRACTOR(S) SHALL SUBMIT SHOP DRAWINGS, SAMPLES, OR MANUFACTURER'S
LITERATURE FOR ALL ITEMS. SHOP DRAWINGS SHALL SHOW SUFFICIENT DETAIL TO DETERMINE COMPLIANCE WITH QUALITY STANDARDS AND DESIGN INTENT.
PROVIDE ALL NECESSARY FURRING AND GROUNDS FOR WOODWORK AND FINISH ITEMS. COORDINATE LOCATION OF BLOCKING WITHIN PARTITIONS FOR ITEMS TO BE
SECURED TO SURFACE. ALL FASTENERS SHALL BE CONCEALED.
C.
A.
B.
GENERAL MILLWORK NOTES
N
S
W E
USE RUBBER REDUCER STRIPS WHERE VINYL FLOORING TRANSITIONS TO CARPET. CONTRACTOR TO SUBMIT COLOR SAMPLES TO DESIGNER FOR APPROVAL. CENTER
TRANSITION STRIP UNDER CENTERLINE OF DOOR OR CENTERLINE OF OPENING, WHICHEVER APPLIES.
CONTRACTOR TO SUBMIT CUTS/SAMPLES OF ALL FINISHES TO DESIGNER FOR APPROVAL PRIOR TO ORDERING.
CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER IF A SPECIFIED FINISH ITEM BECOMES UNAVAILABLE.
G. INSTALL NEW OWNER PROVIDED BLINDS AT ALL EXISTING WINDOWS.
I.
H.
GENERAL FINISH NOTES
CENTER ALL APPLICABLE CARPET LINES UNDER CENTERLINE OF DOOR (WHILE IN CLOSED POSITION).
PAINT ALL GRILLES, ETC., TO MATCH SURFACE ON WHICH THEY OCCUR.
FLOORING CONTRACTOR TO LEVEL EXISTING SUBSTRATE AS NEEDED TO ACCEPT NEW FLOORING MATERIAL AND PROVIDE SEAMING DIAGRAM FOR CARPET
LAYOUT FOR DESIGNER APPROVAL PRIOR TO INSTALLATION, IF FLOORING MATERIALS DEMANDS IT.
USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES.
PROCEEDING WITH THE INSTALLATION OF FINISHES WILL BE CONSTRUED THAT THE INSTALLER AND/OR FINISHER HAS INSPECTED AND ACCEPTED THE SUBSTRATE FOR
RECEIVING THE WORK. NO CHANGE ORDER WILL BE ISSUED TO RECTIFY CONCEALED, UNKNOWN CONDITIONS OR UNSATISFACTORY SUBSTRATE ONCE THE FINISH
WORK HAS PROCEEDED.
A.
B.
C.
E.
F.
D.
J. ALL GYP. BD. CEILINGS AND BULKHEADS TO BE PAINTED. COLOR TBD.
K. ALL FINISHES TO COMPLY WITH CLASS 3 FLAME SPREAD RATING.
L. CAULK ALL TOLIET FIXTURES TO WALL USING SILICONE SEALANT.
M. CAULK ALL COUNTERTOPS AND BACK SPLASHES TO WALL USING SILICONE SEALANT IN COLORS TO BE SELECTED BY DESIGN TEAM.
FINISH PLAN
AG
AEM/ SA
THE INFORMATION CONTAINED HEREIN IS THE EXCLUSIVE PROPERTY OF
H.C.O., INC., AND IS THEREBY PROTECTED UNDER COPYRIGHT LAWS. THE
ORIGINAL IDEAS REPRESENTED HERE BY THIS INFORMATION SHALL NOT
BE USED, ALTERED, OR REPRODUCED IN ANY MANNER WITHOUT THE
EXPRESSED WRITTEN CONSENT OF H.C.O., INC.
SHEET NO:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE:
REVISIONS:
CONSTRUCTION DOCUMENTS
COMPASS
RESIDENTIAL
OFFICE LAYOUT
9660 COMMERCE DR SUITE 100 & 101
CARMEL, INDIANA 46032
02.09.2018
P:\AE INTERIOR DESIGN\PROJECTS\2017-8 J Benzal\Drawings\ARCHITECTURAL\steve's stamp.jpg
AE DESIGNS
INTERIOR DESIGN
(317) 974-9328
Info@
TheAeExperience.com
FINISH SPECIFICATIONS
PT-1 SHERWIN WILLIAMS
SEMI-GLOSS ENAMEL
TBD
LEGEND:
PT- PAINT
CPT- CEILING PAINT
CARP- CARPET TILE
VCT- VINYL COMPOSITION TILE
PORC- PORCELAIN
SC- SEALED CONCRETE
RB- 4" COVE RUBBER BASE
WALL FINISHES
FLOOR FINISHES
CARP-1 PATCRAFT
TBD
VCT-1 ARMSTRONG
CPT-1 SHERWIN WILLIAMS
SEMI-GLOSS ENAMEL
SW7004
SNOWBOUND
FLOORING LEGEND
CARP- CARPET TILE
VCT- VINYL COMPOSITION TILE
PORC- EXISTING PORCELAIN
SEALED CONCRETE
03/16/18