Loading...
HomeMy WebLinkAboutME 1.1 Mechanical Electrical PlanCOMMON SUITE 100 38'-10" x 76'-5" SUITE 101 38'-10" x 76'-5" PROGRAMMING DESKS 15'-10" x 32'-1" QC DESKS 17'-3" x 16'-0" OFFICE 9'-0" x 12'-0" OFFICE 8'-6" x 12'-0" OFFICE 12'-7" x 9'-8" OFFICE 11'-3" x 9'-8" KITCHEN 14'-4" x 15'-8" OFFICE 10'-3" x 10'-0" OFFICE 13'-10" x 10'-0" RECEPTION 23'-10" x 14'-5" OFFICE 9'-8" x 14'-4" OFFICE 9'-11" x 16'-0" OFFICE 9'-7" x 16'-0" OFFICE OFFICE 17'-7" x 10'-0" 10'-3" x 10'-0" HALLWAY 17'-10" x 26'-0" OFFICE 10'-10" x 11'-8" OFFICE 12'-2" x 11'-8" OFFICE 9'-4" x 16'-1" OFFICE 10'-3" x 15'-8" HALLWAY 28'-7" x 16'-11" OFFICE 13'-10" x 10'-0" OPEN 18'-8" x 23'-7" CONFERENCE ROOM 9'-11" x 16'-1" TRAINING ROOM 24'-2" x 26'-5" N S W E MECHANICAL ELECTRICAL PLAN AG AEM/ SA DED Dedicated circuit GFCI Wall Receptacle: 120V, duplex - Install w/ ground pin Wall Receptacle: 120V, duplex on Ground Fault Circuit Interrupter ELECTRICAL LEGEND Wall Receptacle: telephone N NEW Receptacle, all others shown are existing ELECTRICAL NOTES VERIFY LOCATIONS AND NUMBER OF LIGHT SWITCHES WITH TENANT PRIOR TO INSTALLATION. VERIFY DEDICATED OUTLETS AND CIRCUITRY REQUIREMENTS WITH TENANT. F. I. J. L. D. E. C. B. A. G. H. K. M. N. O. P. ELECTRICAL/DATA OUTLET LOCATIONS TO BE COORDINATED WITH TENANT PRIOR TO ROUGH-IN. CONTRACTOR TO VERIFY ALL LOCATIONS WITH FURNITURE & EQUIPMENT PLACEMENT. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH GC FURTHER TECHNICAL INFORMATION. DO NOT SCALE DRAWINGS. ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST W/ NEW CONSTRUCTION MUST BE REVIEWED BY THE ARCHITECT/ DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHING RECEPTACLES TO NEAREST STUD. PROVIDE EMERGENCY STROBES AND HORNS AS REQUIRED BY STATE AND LOCAL BUILDING CODES. FA CONTRACTOR TO COORDINATE ANY REQUISITE ALTERATIONS W/ OWNER. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL BE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS. ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUPS OF OUTLETS, UNLESS NOTED OTHERWISE. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE WHITE COLOR. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED 18" A.F.F. TO CENTERLINE OF OUTLET, UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LIGHTING REQUIREMENTS OF MILLWORK WITH ARCHITECTURAL WOODWORK CONTRACTOR AS NECESSARY. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AT TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) ARE PROVIDED BY THE TENANT UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR TO COORDINATE SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS OF TENANT'S AS SPECIFICALLY INDICATED ON DRAWINGS. VERIFY ACTUAL REQUIREMENTS WITH ARCHITECT/DESIGNER PRIOR TO INSTALLATION. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION. ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS. THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NONCOMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIAL, EQUIPMENT, AND CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. New Electrical Panel: A: Emergency Lighting 100A 120V Single Phase B: Heating/ Cooling 225A 120/ 208V 3-Phase C: Unit 300 Service 225A 120/ 208V 3-Phase J Junction Box # KEYED LIGHTING NOTES 1 2 NO NEW SERVICE OR PANEL- RECONFIGURE OF EXISTING BRANCH CTS ONLY. New Emergency Light: Evenlite Inc., TLM2W Wall Receptacle: 240V, duplex - Install w/ ground pin FEC Fire Extinguisher Cabinet ILLUMINATED EXIT SIGN WITH BATTERY BACKUP PLUMBING NOTES A. NO PLUMBING IN SUITES. Existing 4plex wall outlet Switching Intent S Single Pole Switch F5: New Can Light Recessed: TBD S 3 3-Way Switch LIGHTING LEGEND + XX" Mounting height to center above finished floor Provide GFCI protection for all 125-volt, single-phase, 15 and 20 ampere receptacles located within 6 feet of all sinks. For GFCI receptacles located behind appliances that are that are not readily accessible to test/reset GFCI, consider using GFCI breakers in the panel board which would be more readily accessible. Q. Support fixtures at each corner independent of the suspended ceiling; or alternatively, use suspended (and supported) ceiling suitable for supporting fixtures and provide rated grid clips at each fixture corner. Use ceiling tie wire same as ceiling. R. Wall Sconces to be ADA compliant so that objects projecting from walls with their leading edges between 27" and 80" above the finished floor shall protrude no more than 4" into walks, halls, corridors, passageways or aisles. S. Exit Sign w/ Emergency Egress Light Twin Head LED w/ Battery Backup 90 min Provide exterior, egress light at exit discharge doorway with battery backup suitable for 90 minutes of operation. Consider the use of a remote head connected to the interior exit light with battery backup. T. Provide not less than one (1) foot-candle average of illumination along means of egress at the walking surface level with a minimum at any point of 0.1 foot-candle. Provide egress lights where necessary. Provide with power backup suitable for 90 minutes of operation. U. V. All electrical wiring will be done with MC cables passed and anchored appropriately through metal studs. Lighting for all exterior applications not excepted in Section 9.1 shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the light is not required during nighttime hours. Lighting not designated for dusk-to-dawn operation shall be controlled by either a) a combination of a photo sensor and a time switch or b) an astronomical time switch. W. Exterior Emergency Egress Light THE INFORMATION CONTAINED HEREIN IS THE EXCLUSIVE PROPERTY OF H.C.O., INC., AND IS THEREBY PROTECTED UNDER COPYRIGHT LAWS. THE ORIGINAL IDEAS REPRESENTED HERE BY THIS INFORMATION SHALL NOT BE USED, ALTERED, OR REPRODUCED IN ANY MANNER WITHOUT THE EXPRESSED WRITTEN CONSENT OF H.C.O., INC. SHEET NO: DRAWN BY: CHECKED BY: PROJECT NO: DATE: REVISIONS: CONSTRUCTION DOCUMENTS COMPASS RESIDENTIAL OFFICE LAYOUT 9660 COMMERCE DR SUITE 100 & 101 CARMEL, INDIANA 46032 02.09.2018 P:\AE INTERIOR DESIGN\PROJECTS\2017-8 J Benzal\Drawings\ARCHITECTURAL\steve's stamp.jpg AE DESIGNS INTERIOR DESIGN (317) 974-9328 Info@ TheAeExperience.com GFCI GFCI 2X4 RECESSED FLUORESCENT FIXTURE S 4 4-Way Switch 03/16/18 Nick Mishler