Loading...
HomeMy WebLinkAboutA0 B-1.21900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office102/20/2015PLAN REVISION201/04/2016PLAN REVISIONS304/29/2016PCR REVISIONS411/14/2016PLAN REVISIONS............... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 RICK STARKEY08/04/2014 LEFT MEADOWVIEW 2058.300.00.CPM -- 04/29/2016 PLOTTED: November 29, 2016 / Annie Ki / 2058-MEADOWVIEW-CZ-BASE-PLAN.DWG A0 B-1.2Basement Foundation PlanOptions SCALE:BASEMENT FOUNDATION PLAN w/ MASONRY1/4" = 1'-0"- OPT. 4140 SL & EGRESS WELL #2, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #3, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #1, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS SLOPE CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) OPT. EJECTOR PIT AND PUMP - VERIFY LOCATION IN FIELD LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) FURNACE, PER SPEC. VERIFY LOCATION W/ MECHANICAL PLANS PERIMETER DRAIN, PER SPEC BASEMENT - UNFINISHEDSLAB (SEE STRUCTURAL PLANS) UP 15 RISERSADD RISER w/ OPT. 9' DEEP POUR 23415678 LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) HANDRAIL, PER CODE SLAB LEDGE, PER DETAIL SUMP w/ CHECK VALVE - VERIFY LOCATION IN FIELD CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) PROVIDE 10' MIN. SEPARATION BETWEEN WATER & SEWER LINES (PER CODE) \pxql;OPT. WATER SOFTENER, PER SPEC RADON VENT AS REQUIRED PER CODE, VERIFY LOCATION WATER HEATER, PER SPEC. VERIFY LOCATION IN FIELD LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION (TYP.) ROUGH IN BATH 1A2 B.11A2 B.1 2A2 B.2 2A2 B.2\A1;6'-0" \A1;58'-7" OVERALL \A1;66'-7" OVERALL \A1;58'-7" OVERALL \A1;66'-7" OVERALL \A1;19'-7"\A1;10'-0"\A1;6'-5"\A1;13'-7"\A1;9'-0"\A1;1'-8"\A1;16'-3"\A1;1'-8"\A1;7"\A1;8'-3"\A1;1'-2" \A1;2'-0" \A1;4'-0" \A1;1'-0" \A1;59'-7" \A1;10'-0"\A1;16'-7"\A1;16'-5"\A1;15'-7" \A1;56'-7" \A1;10'-0"\A1;10'-0" \A1;32'-2{\H0.750000x;\S1#2;}" \A1;2'-0" \A1;18'-6" \A1;4'-0{\H0.750000x;\S1#2;}" \A1;3'-10{\H0.750000x;\S1#2;}" \A1;6'-0" \A1;10'-4{\H0.750000x;\S1#2;}" \A1;10'-6"\A1;12'-9{\H0.750000x;\S1#2;}" \A1;10'-0" \A1;10'-4{\H0.750000x;\S1#2;}" \A1;6'-6" \A1;53'-3{\H0.750000x;\S1#2;}" \A1;6'-3{\H0.750000x;\S1#2;}" \A1;8'-3{\H0.750000x;\S1#2;}"\A1;8'-3{\H0.750000x;\S1#2;}"\A1;7'-10{\H0.750000x;\S1#2;}"\A1;7'-8{\H0.750000x;\S1#2;}" \A1;25'-11" \A1;6'-3{\H0.750000x;\S1#2;}" \A1;21'-8{\H0.750000x;\S1#2;}" - ℄ OF OPT. DOOR \A1;2'-8" \A1;21'-4"\A1;7'-3{\H0.750000x;\S1#2;}"\A1;21'-4" \A1;3'-0" \A1;9'-4{\H0.750000x;\S1#2;}" \A1;3'-0" \A1;3'-8{\H0.750000x;\S1#2;}"\A1;2'-7{\H0.750000x;\S1#2;}" \A1;3'-10{\H0.750000x;\S1#2;}"\A1;3'-7" \A1;3'-10{\H0.750000x;\S1#2;}" \pxql;2X6 WALL FD POST & BEAM PER STRUCTURAL PLANS ALTERNATE SUMP PUMP LOCATION - VERIFY LOCATION IN FIELD OPT. 4140 SL & EGRESS WELL #3, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS \A1;6'-0"\A1;7'-7" SCALE:ALTERNATE SUMP PUMP LOCATION1/4" = 1'-0"- Sump Pit Std. 03/21/18 Mike Sheeks