Loading...
HomeMy WebLinkAbout18030157 Building PlansDRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:34 PM Carmel, IN 46032 1095 Laurelwood COVER SHEET COVER STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET CONTACTS: ARCHITECTURAL PERMIT-BUILD SET Fill in Name Fill in Phone # CSH Position Fill in Name Fill in Phone # CSH Position Fill in Name Fill in Phone # CSH Position ARCHITECTURAL DESIGNER EMILY TREECE 317.965.6479 EMILY@CSHOMES.COM GENERAL CONTRACTOR SCOTT BATES 317.408.4853 SCOTT@CSHOMES.COM GENERAL CONTRACTOR CHRIS CARNELL 317.590.7961 CHRIS@CSHOMES.COM DATE REV. BY DESCRIPTION MAIN LEVEL 0" UPPER LEVEL 11'-4 1/4" T.O. PL - UPPER LEVEL 20'-5 3/4" APPROX T.O. ROOF 33'-6 101/128" T.O. FOUNDATION -1'-4 1/4" T.O. PLATE 10'-1 1/2" 15:12 10:12 10:12 10:12 10:12 10:12 10:12 15:12 15 12 15 12 15 12 10 12 10 12 15 12 15 12 10 12 10 12 10 12 10 12 10 12 10 12 15 12 15 12 15 12 15 12 10:12 8:12 8:12 8 12 8 12 MAIN LEVEL 0" UPPER LEVEL 11'-4 1/4" 1'-4 1/4" 10'-1 1/2" 1'-2 3/4" 9'-1 1/2" T.O. PL - UPPER LEVEL 20'-5 3/4" VERIFY ACTUAL NUMBER OF STEPS AND HEIGHTS w/ FINAL GRADE, TYP ACTUAL GRADE TO BE DETERMINED ON SITE SHINGLE ROOF APPROX T.O. ROOF 33'-6 101/128" T.O. FOUNDATION -1'-4 1/4" T.O. PLATE 10'-1 1/2" 13'-7 39/128" 15:12 10:12 10:12 15:12 15:12 15:12 10:12 15:12 15:12 15:12 10:12 15:12 10:12 10 12 10 12 10 12 15 12 HORSE WEATHERVANE ON CUPOLA 4'-10" 4'-10" 15:12 15:12 15:12 10:12 10:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 Slide Cavity 30" DIAMETER, 12' HT SLIDE EXIT SLIDE WELCOME TO THE DRIVE-IN LIGHT UP SIGNAGE ABOVE OPENING Elevator Drive-in Theater 10'-3" 3 1/2" 4'-0" 3 1/2" 3 1/2" 19'-2" 5'-9" 16'-10" 5 1/2" 23'-4" 3 1/2" 4'-5" 3 1/2" 14'-10 1/2" 5 1/2" 23'-8 1/2" 3 1/2" 4'-10" 3 1/2" 5'-8" Prize Counter 1'-6" 3'-0" 10" 9'-7" 25'-3" Security HVAC / Unheated Storage The Cloud Gun Room SECRET STEEL DOOR 16'-5 1/2" 3 1/2" 9'-2 1/2" 3 1/2" 11'-7 1/2" Arcade Unheated Storage 28'-7" 3'-2 1/2" 22'-0" 13'-9 1/2" 4'-0" 12'-2" 36'-2" 10'-9" 10'-4" 54'-10 1/2" 6'-0" 10" 18'-11" 10" 16'-5 1/2" 25'-5" 123'-4" 3'-6" 4'-9" 14'-4" 12'-2" 15'-6" 9'-4" 15'-6" 11'-4" 10'-1 1/2" 10" 5" 15'-2" 10" 9'-6 1/2" 96'-6 1/2" PINBALL MACHINE 28" X 56" PINBALL MACHINE 28" X 56" SUPER SHOT BASKETBALL 34"W x 126"L x 108"H DOWN THE CLOWN 45"W X 117"L X 110"H AIR HOCKEY TABLE 50"W X 90"L "Y" "X" "Z" "W" WALLS 3'-6" 4'-9" 13'-6" 13'-0" 15'-6" 8'-6" 15'-6" 7" 3 1/2" 5'-2 1/2" 3'-9" 10'-0 1/2" 27'-9" 4'-0" 21'-3" 14'-7" 4'-0" 12'-2" 30'-4" 7'-6" 4'-3" 14'-9" 2'-6" 3 1/2" 14'-1" 2'-6" 2'-0 1/2" 3 1/2" 4'-5 1/2" 3 1/2" 16'-3 1/2" 5'-8 1/2" 6'-10 1/2" 3 1/2" 9'-6 1/2" 3 1/2" 6'-7" 3 1/2" 11'-5" 3 1/2" 10'-4 1/2" 5 1/2" 32'-3 1/2" 20'-2" 27'-1" 4'-6 1/2" 4'-5 1/2" 3 1/2" 3'-4" 3 1/2" 5'-2 1/2" 3 1/2" 3'-8" 6'-6 1/2" Her W.I.C. Study Play Room / Guest Suite Pool Bath Powder Planning Room Garage - Attached Elevator Slide Cavity 6'-1 1/2" 9" 5'-6" 7'-11" 5'-6" 17'-9" 12'-11" 30'-2 1/2" 19'-2 1/2" 17'-0" 25'-5" 14'-9" 5 1/2" 22'-0" 5 1/2" 18'-9" 4'-0" 30" DIAMETER, 12' HT SLIDE ENTER SLIDE (BOT OF OPEN. APPROX 1'-4" AFF) Master Bedroom Master Bath Kitchen 2'-1 1/2" 4'-6" 5'-0" 8'-7 1/2" 3'-4" 4'-9 1/2" 5 1/2" 5'-8 1/2" 3 1/2" 14'-9" 5 1/2" 22'-0" 5 1/2" 5'-6" 3 1/2" 4'-0" 3 1/2" 8'-5" 3 1/2" 4'-11" 3 1/2" 4'-10" 3 1/2" 7" 3 1/2" 14'-6" 3 1/2" 23'-8 1/2" 5 1/2" 19'-2" 21'-6 1/2" Bedroom 3 Bedroom 4 Elevator 6'-0" 6'-8" 4'-0" 4'-6" 39'-6" 45'-4" Bedroom 2 6'-10 1/2" 9'-10 1/2" 6'-9" 7'-7" 5'-9" 1'-0" 5'-9" 6'-6" 3'-10" 6'-6" 8'-10 1/2" Linen LAUNDRY CHUTE OPEN TO BELOW OPEN TO BELOW 3'-7 1/2" 6'-2" 6'-3" 8'-9 1/2" 3'-8" 6'-6" 2'-8" 6'-6" 3'-1 1/2" 19'-9" 10'-1" 5'-10" 6'-1" 13'-5 1/2" 3'-6" 4'-0" 6" 6'-8 1/2" 5'-6 1/2" 5'-1" 19'-5" 8'-6" 2'-0 1/2" 6'-3" 6'-6" 6'-0" 7'-3 1/2" 4'-8" 2'-4 1/256" 6'-6" 8" 3'-2" 6'-6" 23'-0" 2'-4" 6" 16'-3 1/2" 14'-6" 7'-1 155/256" PL. HT. 7'-1 1/2" PL. HT. 4'-11 1/2" 3 1/2" 9'-5 1/2" 5 1/2" 21'-6" 10'-2 1/2" 5'-9 1/2" 6" 7'-4" HVAC Bedroom 5 7'-1 155/256" PL. HT. 7'-1 1/2" PL. HT 7'-9" 12'-0" 12'-0" 7'-9" 43'-0" 2'-4" 5'-8 1/4" PL. HT. 5'-7 31/64" PL. HT. 5'-1" 5'-2 1/2" 9'-5" 5'-1" 3 1/2" 13'-2" CLOSED SOFFIT AT MAIN FLOOR PLATE 15:12 15:12 15:12 15:12 15:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 15:12 15:12 15:12 10:12 15:12 15:12 15:12 15:12 15:12 10:12 10:12 15:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 15:12 10:12 10:12 10:12 10:12 10:12 10:12 15:12 15:12 15:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:12 15:12 15:12 15:12 15:12 15:12 8'-3" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 7'-7" 8'-3" 10:12 10:12 8:12 40'-0" 40'-0" 75'-0" B.S.B.L. TO FACE OF BRICK WALL = 6" EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING swimming pool hot tub circular driveway (STAMPED CONCRETE PAVER PATTERN) raised planter w/ tree & shrubs driveway (STAMPED CONCRETE PAVER PATTERN) (2) guest parking spots (2) car garage (4) car garage covered patio lake edge of water edge of water 40' building setback line 40' building setback line B.S.B.L. TO CORNER OF BRICK WALL = 8" PLANTING BED 75' building setback line 75' building setback line 40' building setback line 40' building setback line U.D. & m. EASEMENT U.D. & m. EASEMENT 10' DRAINAGE EASEMENT DIVING BOARD driveway (STAMPED CONCRETE PAVER PATTERN) PLANTING BED 15'-6" 9'-0" 15'-6" 9'-11" 3'-0" 20'-0" 7'-0" 40'-0" 5'-4 1/2" 8'- 11" 40'-1 109/128" DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 VOLUME CONTROL KNOB LIGHTING OR ELECTRONICS (LCD DISPLAY OR LIGHTING AUTOMATION PUSH BUTTON CONTROLLER) * USE MAX OF 6 GANG BOXES. FOR GANG BOXES OF 3 OR MORE THAT ARE LOCATED ON BLOCK WALL, CHIP OUT THE BLOCK TO ACCOMMODATE DEEPER BOX. NOTE: ALL DIMENSIONS ARE FOR ROUGH FRAMING ELECTRICAL DETAILS THE ITEMS BELOW ARE SHOWN FOR LOCATION PURPOSES ONLY. PLEASE REFER TO LOCAL SPECS TO DETERMINE WHETHER OR NOT THE FOLLOWING ITEMS ARE INCLUDED: SCALE: 1/2"=1'-0" BATH MOUNTING HTS FOR OUTLET AND SW BTM OF SW AND OUTLET TO ALIGN KITCHEN MOUNTING HTS FOR OUTLET AND SW LCD DISPLAY ALIGNED W/ EDGE OF SW * SWITCHES EDGE OF OUTLET AND CAB FACE TO ALIGN DOOR JAMB OR WALL CORNER DUPLEX OUTLET UPDATED 7/11/16 1'-0" 3'-0" 1'-4" 3'-3" ROUGH 4 1/2" 3'-7" CL OF CBNT CL CL DUPLEX OUTLET (110V AT 45") * DUPLEX OUTLET (110V AT 43") * WEATHERPROOF DPLX OUTLET (110V AT 12") SPLIT DPLX OUTLET (11OV AT 12") TOP IS 'HOT' TOP PLUG IS 'HOT' WEATHERPROOF DPLX OUTLET (110V AT 12") DUPLEX OUTLET (110V AT 39") * ELECTRICAL LEGEND DUPLEX OUTLET (110V AT 12" OR AS NTD) • NOTE: ALL OUTLETS ABOVE COUNTERS SHALL BE MOUNTED HORIZONTALLY 30" DIAMETER, 12' HT SLIDE FLUSH BEAM FLUSH BEAM DROP BEAM DROP OR FLUSH BEAM AS REQ'D DROP OR FLUSH BEAM AS REQ'D FLUSH BEAM DROP BEAM, HT AFF TBD FLUSH BEAM FLUSH BEAM FLUSH BEAM FLUSH BEAM FLUSH BEAM DROP BEAM DROP OR FLUSH BEAM AS REQ'D DROP OR FLUSH BEAM AS REQ'D FLUSH BEAM CEILING SLOPED FOR STAIR ABOVE 10'-1 1/2" CLG HEIGHT VAULTED CEILING, FUR DOWN ROOFLINE 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CLG HT. APPROX. 4'-10" HT. FIN. CLG BELOW LANDING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING OPEN TO ABOVE OPEN TO ABOVE 10'-1 1/2" CEILING 10'-1 1/2" CLG HT 10'-1 1/2" CLG HEIGHT OPEN TO ABOVE, VAULTED CEILING, W/ 10X10 COLLAR TIES AT 13' AFF 10'-1 1/2" CLG HT. 10'-1 1/2" CLG HT. VAULTED CEILING ABOVE Her W.I.C. Study Play Room / Guest Suite Pool Bath Powder Planning Room Pantry Garage - Attached Elevator Slide Cavity Master Bedroom Master Bath Kitchen Dining OPEN TO BELOW OPEN TO BELOW VAULTED DORMER ABOVE VAULTED DORMER ABOVE 9'-1 1/2" CEILING SLOPED CEILING VAULTED DORMER ABOVE VAULTED DORMER ABOVE BARREL VAULT ABOVE BARREL VAULT ABOVE SLOPE CLG TO FOLLOW ROOF OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING 8'-1 1/2" CLG 9'-1 1/2" CLG HT. 9'-1 1/2" CLG 9'-1 1/2" CLG 8'-1 1/2" CLG OPEN TO ABOVE, VAULTED CEILING Bedroom 3 Bedroom 4 Elevator Bedroom 2 Linen HVAC Bedroom 5 Unheated Storage Bath5 4 Bath WIC 4 WIC 5 WIC 2 Bath 2 WIC 3 Bath 3 9'-1 1/2" CEILING 9'-1 1/2" CLG HT. 9'-1 1/2" CLG 1'-3" 1'-3" 1'-3" 1'-3" EQ EQ EQ EQ 5'-2" 8'-0 1/2" 2'-4 1/2" 7'-9 1/2" 1'-3" 1'-3" 1'-3" EQ EQ 2'-8 1/4" EQ EQ EQ EQ EQ EQ EQ EQ 5'-10 1/2" 4'-10 1/2" 2'-10" OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING Kids' Loft Unheated Storage DUPLEX OUTLET (110V AT 45") * DUPLEX OUTLET (110V AT 43") * WEATHERPROOF DPLX OUTLET (110V AT 12") SPLIT DPLX OUTLET (11OV AT 12") TOP IS 'HOT' TOP PLUG IS 'HOT' WEATHERPROOF DPLX OUTLET (110V AT 12") DUPLEX OUTLET (110V AT 39") * ELECTRICAL LEGEND DUPLEX OUTLET (110V AT 12" OR AS NTD) • NOTE: ALL OUTLETS ABOVE COUNTERS SHALL BE MOUNTED HORIZONTALLY • NOTE: ALL 125V, 15 AND 20 AMP OUTLETS TO BE TAMPER- RESISTANT IN AREAS SPECIFIED BY NEC 2008 406.11. • NOTE: ALL EXTERIOR OUTLETS, OUTLETS IN GARAGE, WALL OUTLETS IN KITCHENS AND BATHROOMS AND ALL OUTLETS WITHIN 6'-0" OF A WATER SOURCE SHALL BE G.F.I. ALL NON- GFI OR 220V OUTLETS ARE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER. ALL HEIGHTS TO CENTERLINE AFF. • NOTE: LIGHTS, FANS, SMOKE DETECTORS, A/C SUPPLIES AND RETURN AIRS TO BE PLACED ON CENTERLINES OF DOORS, WDWS AND HALLWAYS, TYP UNO • NOTE: SMOKE DETECTORS SHALL BE INSTALLED PER NFPA72. • NOTE: COORDINATE LOCATION OF ALL REQ. ELECTRICAL, CABLE, AUDIO/VIDEO & DATA RECEPTACLES W/ MOUNTING HARDWARE & MFR. INSTALLATION REQ. FOR ALL FLAT PANEL DISPLAYS. DIMMER SW AT 36" PUSH-BUTTON FOR GARAGE DOOR AT 60" PUSH-BUTTON DOORBELL CHIMES CLG MNT SPEAKER A/C REGISTER THERMOSTAT SECURITY PAD RETURN AIR grille ELEC PANEL EXHAUST FAN SW SEE ELEC DTL RECESS FLOOR OUTLET 220V OUTLET AT 30" SPECIAL PURPOSE CONN SOFFIT MNT FLOOD LIGHT EXHAUST FAN / LIGHT FIXTURE COMBO SMOKE & CARBON MONOXIDE DETECTOR CLG FAN/LIGHT PREWIRE AND SWITCHES 4-WAY SW SEE ELEC DTL 3-WAY SW SEE ELEC DTL 6" ROUND SLOPE CLG RECESS WITH 2700K LED BULB (INTERIOR SLOPED CLG) 6" ROUND RECESS 2700K LED RETROFIT TRIM W/OPEN BAFFLE SURFACE MNT FIXTURE CLG MNT LT FIXTURE WALL MNT FIXTURE CLG MNT PREWIRE - FIXTURE BY OWNER 2 1/2" MINI ROUND LED 3000K 4" MINI ROUND RECESS 2700K LED RETROFIT TRIM W/OPEN BAFFLE T TP U-9 S F 24 36 24 U-22 A 9 10 11 4 C B 8 S 4 3 S S 24" CLG MNT FLUOR. LT, WRAPPED 24" VANITY LIGHTING (SEE SPECS) 36" VANITY LIGHTING (SEE SPECS) UNDER CABT LED 9" UNDER CABT LED 22" UNDER CABT LED 30" UNDER CABT LED 14" UPDATED 7/11/17 1-GANG COMBINATION FAN / LIGHT SWITCH S OCCUPANCY/MOTION DETECTOR SWITCH OC S 4" MINI ROUND RECESS 2700K LED EYEBALL TRIM U-14 U-30 48 48" CLG MNT FLUOR. LT, WRAPPED OUTLET w/ USB PORTS(110V AT 12" OR AS NTD) TELEPHONE OUTLET AT 12" OR AS NOTED clg wall VOLUME CONTROL KNOB LIGHTING OR ELECTRONICS (LCD DISPLAY OR LIGHTING AUTOMATION PUSH BUTTON CONTROLLER) * USE MAX OF 6 GANG BOXES. FOR GANG BOXES OF 3 OR MORE THAT ARE LOCATED ON BLOCK WALL, CHIP OUT THE BLOCK TO ACCOMMODATE DEEPER BOX. NOTE: ALL DIMENSIONS ARE FOR ROUGH FRAMING ELECTRICAL DETAILS THE ITEMS BELOW ARE SHOWN FOR LOCATION PURPOSES ONLY. PLEASE REFER TO LOCAL SPECS TO DETERMINE WHETHER OR NOT THE FOLLOWING ITEMS ARE INCLUDED: SCALE: 1/2"=1'-0" BATH MOUNTING HTS FOR OUTLET AND SW BTM OF SW AND OUTLET TO ALIGN KITCHEN MOUNTING HTS FOR OUTLET AND SW LCD DISPLAY ALIGNED W/ EDGE OF SW * SWITCHES EDGE OF OUTLET AND CAB FACE TO ALIGN DOOR JAMB OR WALL CORNER DUPLEX OUTLET UPDATED 7/11/16 1'-0" 3'-0" 1'-4" 3'-3" ROUGH 4 1/2" 3'-7" CL OF CBNT CL CL DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:21 PM Carmel, IN 46032 1095 Laurelwood UPPER LEVEL ELECTRICAL PLAN 7c STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET 1/4" = 1'-0" UPPER LEVEL ELECTRICAL PLAN RECESSED FLOOR OUTLET (FULLY CONCEAL BELOW FLOOR LEVEL) #68-P W/COVER PLATE BY: THOMAS & BETTS, INC. OR EQUAL FLOOR OUTLET NOTE: BUILDING COMPANY TO COORDINATE ALL TV AND CABLE OUTLETS W/LOW VOLTAGE CONTRACTOR LOW VOLTAGE NOTE: ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER ALL RECESSED CANS MUST BE LED, SEE ELECTRICAL LEGEND FOR SIZE AND COLOR TEMPERATURE RECESSED CAN NOTE: !! NOTE !! UNDER CABINET LIGHTING & SWITCHES SHOWN FOR LOCATION PURPOSES ONLY, PLEASE REFER TO BUILDING COMPANY STANDARDS. DATE REV. BY DESCRIPTION Mud Room Great Room Foyer Hearth Garage - Detached Covered Patio Play House His W.I.C. Hallway WIC PLAY HVAC CLOSET 10'-1 1/2" CLG HT BARREL VAULT ABOVE 8'-6" HEADER AFF EQ EQ 2'-9" 6'-4" 2'-9" 4'-9" EQ EQ EQ EQ EQ EQ 1'-3" 6'-2 1/2" 5'-1 1/2" 7'-0" 7'-0" EQ EQ EQ EQ EQ EQ EQ EQ 9'-6 1/8" 3'-5 7/8" 5'-0 1/2" 5'-5 5/16" 6'-6 1/8" 5 7/8" 6" 3'-3" 6'-3 1/8" 2 7/8" 3'-3" 5'-9" EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 2'-9" 6'-3 1/2" 2'-9" EQ EQ EQ EQ EQ EQ 3'-7 1/4" 7'-5 1/2" 3'-7 1/4" EQ EQ EQ EQ 3'-0" EQ EQ 1'-3" 1'-3" 1'-3" 1'-3" 24'-10 1/2" EQ EQ EQ EQ EQ EQ EQ EQ TESLA CAR CHARGER? AC UNIT AC UNIT AC UNIT AC UNIT AC UNIT POOL EQUIPMENT LOCATION EQ EQ EQ EQ 12'-1 1/2" CEILING 10'-7 1/2" CEILING VAULTED CEILING ABOVE VOLUME CONTROL KNOB LIGHTING OR ELECTRONICS (LCD DISPLAY OR LIGHTING AUTOMATION PUSH BUTTON CONTROLLER) * USE MAX OF 6 GANG BOXES. FOR GANG BOXES OF 3 OR MORE THAT ARE LOCATED ON BLOCK WALL, CHIP OUT THE BLOCK TO ACCOMMODATE DEEPER BOX. NOTE: ALL DIMENSIONS ARE FOR ROUGH FRAMING ELECTRICAL DETAILS THE ITEMS BELOW ARE SHOWN FOR LOCATION PURPOSES ONLY. PLEASE REFER TO LOCAL SPECS TO DETERMINE WHETHER OR NOT THE FOLLOWING ITEMS ARE INCLUDED: SCALE: 1/2"=1'-0" BATH MOUNTING HTS FOR OUTLET AND SW BTM OF SW AND OUTLET TO ALIGN KITCHEN MOUNTING HTS FOR OUTLET AND SW LCD DISPLAY ALIGNED W/ EDGE OF SW * SWITCHES EDGE OF OUTLET AND CAB FACE TO ALIGN DOOR JAMB OR WALL CORNER DUPLEX OUTLET UPDATED 7/11/16 1'-0" 3'-0" 1'-4" 3'-3" ROUGH 4 1/2" 3'-7" CL OF CBNT CL CL DUPLEX OUTLET (110V AT 45") * DUPLEX OUTLET (110V AT 43") * WEATHERPROOF DPLX OUTLET (110V AT 12") SPLIT DPLX OUTLET (11OV AT 12") TOP IS 'HOT' TOP PLUG IS 'HOT' WEATHERPROOF DPLX OUTLET (110V AT 12") DUPLEX OUTLET (110V AT 39") * ELECTRICAL LEGEND DUPLEX OUTLET (110V AT 12" OR AS NTD) • NOTE: ALL OUTLETS ABOVE COUNTERS SHALL BE MOUNTED HORIZONTALLY • NOTE: ALL 125V, 15 AND 20 AMP OUTLETS TO BE TAMPER- RESISTANT IN AREAS SPECIFIED BY NEC 2008 406.11. • NOTE: ALL EXTERIOR OUTLETS, OUTLETS IN GARAGE, WALL OUTLETS IN KITCHENS AND BATHROOMS AND ALL OUTLETS WITHIN 6'-0" OF A WATER SOURCE SHALL BE G.F.I. ALL NON- GFI OR 220V OUTLETS ARE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER. ALL HEIGHTS TO CENTERLINE AFF. • NOTE: LIGHTS, FANS, SMOKE DETECTORS, A/C SUPPLIES AND RETURN AIRS TO BE PLACED ON CENTERLINES OF DOORS, WDWS AND HALLWAYS, TYP UNO • NOTE: SMOKE DETECTORS SHALL BE INSTALLED PER NFPA72. • NOTE: COORDINATE LOCATION OF ALL REQ. ELECTRICAL, CABLE, AUDIO/VIDEO & DATA RECEPTACLES W/ MOUNTING HARDWARE & MFR. INSTALLATION REQ. FOR ALL FLAT PANEL DISPLAYS. DIMMER SW AT 36" PUSH-BUTTON FOR GARAGE DOOR AT 60" PUSH-BUTTON DOORBELL CHIMES CLG MNT SPEAKER A/C REGISTER THERMOSTAT SECURITY PAD RETURN AIR grille ELEC PANEL EXHAUST FAN SW SEE ELEC DTL RECESS FLOOR OUTLET 220V OUTLET AT 30" SPECIAL PURPOSE CONN SOFFIT MNT FLOOD LIGHT EXHAUST FAN / LIGHT FIXTURE COMBO SMOKE & CARBON MONOXIDE DETECTOR CLG FAN/LIGHT PREWIRE AND SWITCHES 4-WAY SW SEE ELEC DTL 3-WAY SW SEE ELEC DTL 6" ROUND SLOPE CLG RECESS WITH 2700K LED BULB (INTERIOR SLOPED CLG) 6" ROUND RECESS 2700K LED RETROFIT TRIM W/OPEN BAFFLE SURFACE MNT FIXTURE CLG MNT LT FIXTURE WALL MNT FIXTURE CLG MNT PREWIRE - FIXTURE BY OWNER 2 1/2" MINI ROUND LED 3000K 4" MINI ROUND RECESS 2700K LED RETROFIT TRIM W/OPEN BAFFLE T TP U-9 S F 24 36 24 U-22 A 9 10 11 4 C B 8 S 4 3 S S 24" CLG MNT FLUOR. LT, WRAPPED 24" VANITY LIGHTING (SEE SPECS) 36" VANITY LIGHTING (SEE SPECS) UNDER CABT LED 9" UNDER CABT LED 22" UNDER CABT LED 30" UNDER CABT LED 14" UPDATED 7/11/17 1-GANG COMBINATION FAN / LIGHT SWITCH S OCCUPANCY/MOTION DETECTOR SWITCH OC S 4" MINI ROUND RECESS 2700K LED EYEBALL TRIM U-14 U-30 48 48" CLG MNT FLUOR. LT, WRAPPED OUTLET w/ USB PORTS(110V AT 12" OR AS NTD) TELEPHONE OUTLET AT 12" OR AS NOTED clg wall 1/4" = 1'-0" MAIN LEVEL ELECTRICAL PLAN DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:19 PM Carmel, IN 46032 1095 Laurelwood MAIN LEVEL ELECTRICAL PLAN 7b STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET RECESSED FLOOR OUTLET (FULLY CONCEAL BELOW FLOOR LEVEL) #68-P W/COVER PLATE BY: THOMAS & BETTS, INC. OR EQUAL FLOOR OUTLET NOTE: BUILDING COMPANY TO COORDINATE ALL TV AND CABLE OUTLETS W/LOW VOLTAGE CONTRACTOR LOW VOLTAGE NOTE: ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER ALL RECESSED CANS MUST BE LED, SEE ELECTRICAL LEGEND FOR SIZE AND COLOR TEMPERATURE RECESSED CAN NOTE: !! NOTE !! UNDER CABINET LIGHTING & SWITCHES SHOWN FOR LOCATION PURPOSES ONLY, PLEASE REFER TO BUILDING COMPANY STANDARDS. DATE REV. BY DESCRIPTION • NOTE: ALL 125V, 15 AND 20 AMP OUTLETS TO BE TAMPER- RESISTANT IN AREAS SPECIFIED BY NEC 2008 406.11. • NOTE: ALL EXTERIOR OUTLETS, OUTLETS IN GARAGE, WALL OUTLETS IN KITCHENS AND BATHROOMS AND ALL OUTLETS WITHIN 6'-0" OF A WATER SOURCE SHALL BE G.F.I. ALL NON- GFI OR 220V OUTLETS ARE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER. ALL HEIGHTS TO CENTERLINE AFF. • NOTE: LIGHTS, FANS, SMOKE DETECTORS, A/C SUPPLIES AND RETURN AIRS TO BE PLACED ON CENTERLINES OF DOORS, WDWS AND HALLWAYS, TYP UNO • NOTE: SMOKE DETECTORS SHALL BE INSTALLED PER NFPA72. • NOTE: COORDINATE LOCATION OF ALL REQ. ELECTRICAL, CABLE, AUDIO/VIDEO & DATA RECEPTACLES W/ MOUNTING HARDWARE & MFR. INSTALLATION REQ. FOR ALL FLAT PANEL DISPLAYS. DIMMER SW AT 36" PUSH-BUTTON FOR GARAGE DOOR AT 60" PUSH-BUTTON DOORBELL CHIMES CLG MNT SPEAKER A/C REGISTER THERMOSTAT SECURITY PAD RETURN AIR grille ELEC PANEL EXHAUST FAN SW SEE ELEC DTL RECESS FLOOR OUTLET 220V OUTLET AT 30" SPECIAL PURPOSE CONN SOFFIT MNT FLOOD LIGHT EXHAUST FAN / LIGHT FIXTURE COMBO SMOKE & CARBON MONOXIDE DETECTOR CLG FAN/LIGHT PREWIRE AND SWITCHES 4-WAY SW SEE ELEC DTL 3-WAY SW SEE ELEC DTL 6" ROUND SLOPE CLG RECESS WITH 2700K LED BULB (INTERIOR SLOPED CLG) 6" ROUND RECESS 2700K LED RETROFIT TRIM W/OPEN BAFFLE SURFACE MNT FIXTURE CLG MNT LT FIXTURE WALL MNT FIXTURE CLG MNT PREWIRE - FIXTURE BY OWNER 2 1/2" MINI ROUND LED 3000K 4" MINI ROUND RECESS 2700K LED RETROFIT TRIM W/OPEN BAFFLE T TP U-9 S F 24 36 24 U-22 A 9 10 11 4 C B 8 S 4 3 S S 24" CLG MNT FLUOR. LT, WRAPPED 24" VANITY LIGHTING (SEE SPECS) 36" VANITY LIGHTING (SEE SPECS) UNDER CABT LED 9" UNDER CABT LED 22" UNDER CABT LED 30" UNDER CABT LED 14" UPDATED 7/11/17 1-GANG COMBINATION FAN / LIGHT SWITCH S OCCUPANCY/MOTION DETECTOR SWITCH OC S 4" MINI ROUND RECESS 2700K LED EYEBALL TRIM U-14 U-30 48 48" CLG MNT FLUOR. LT, WRAPPED OUTLET w/ USB PORTS(110V AT 12" OR AS NTD) TELEPHONE OUTLET AT 12" OR AS NOTED clg wall FLUSH STEEL BEAM, DRILL HOLES FOR HVAC FLUSH OR DROP BEAM FLUSH OR DROP BEAM FLUSH BEAM DROP BEAM DROP BEAM DROP BEAM BEAMS FOR FIREPLACE ABOVE BEAMS FOR FIREPLACE ABOVE FLUSH BEAM 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT APPROX. 8'-6" CLG HT. 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT OPEN TO ABOVE 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT DROP SOFFIT DROP SOFFIT DROP SOFFIT Slide Cavity Elevator Drive-in Theater Prize Counter Security HVAC / Unheated Storage The Cloud Gun Room Arcade Unheated Storage Soda Fountain Lower Bath Unexcavated Unexcavated Unexcavated DROP SOFFIT EQ EQ 5'-2 3/4" 6'-0" 6'-0" EQ EQ PINBALL MACHINE 28" X 56" PINBALL MACHINE 28" X 56" SUPER SHOT BASKETBALL 34"W x 126"L x 108"H DOWN THE CLOWN 45"W X 117"L X 110"H AIR HOCKEY TABLE 50"W X 90"L CLASSIC STANDING 25" x 42" CLASSIC STANDING 25" x 42" RACE CAR GAME 41" x 63" RACE CAR GAME 41" x 63" SKEE BALL 30"W x 120"L x 84"H SKEE BALL 30"W x 120"L x 84"H MEGA STACKER LITE 67"W x 50"D x 109"H 5'-0 1/2" 8'-0" FACE PLACE PIX PHOTO BOOTH 44" x 63" x 69.5" 3'-6 1/2" 5'-6 1/2" 3'-5 3/4" 5'-0 1/2" 3'-5 3/4" 1'-0" 6'-0" 1'-0" 3'-10 1/2" 4'-6" RACE CAR GAME 41" x 63" RACE CAR GAME 41" x 63" CRANE GAME 36" x 30" x 76" WHAC-A-MOLE 30"W x 28"L FUTURE FUTURE DEDICATED 20 AMP CIRCUIT FOR TRUCK DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:16 PM Carmel, IN 46032 1095 Laurelwood LOWER LEVEL ELECTRICAL PLAN 7a STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET RECESSED FLOOR OUTLET (FULLY CONCEAL BELOW FLOOR LEVEL) #68-P W/COVER PLATE BY: THOMAS & BETTS, INC. OR EQUAL FLOOR OUTLET NOTE: BUILDING COMPANY TO COORDINATE ALL TV AND CABLE OUTLETS W/LOW VOLTAGE CONTRACTOR LOW VOLTAGE NOTE: ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER ALL RECESSED CANS MUST BE LED, SEE ELECTRICAL LEGEND FOR SIZE AND COLOR TEMPERATURE RECESSED CAN NOTE: !! NOTE !! UNDER CABINET LIGHTING & SWITCHES SHOWN FOR LOCATION PURPOSES ONLY, PLEASE REFER TO BUILDING COMPANY STANDARDS. 1/4" = 1'-0" LOWER LEVEL ELECTRICAL PLAN *INCLUDE LED 'STARRY SKY' LIGHTING THROUGHOUT THEATER CEILING DATE REV. BY DESCRIPTION 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:13 PM Carmel, IN 46032 1095 Laurelwood SITE PLAN 7 STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET 1" = 10'-0" ARCHITECTURAL SITE PLAN LEGEND *sOLID GREY FILLED AREA INDICATES UNBUILDABLE AREA PER B.S.b.l. AND EASEMENTS PER LAURELWOOD & CITY OF CARMEL *TREES TO REMAIN ON PROPERTY ARE INDICATED AS 'EXISTING' *TREES, SHRUBS, AND OTHER LANDSCAPING WITH NO LABEL ARE PLACEHOLDERS TO INDICATE APPROX. LOCATIONS AND SIZES OF PLANTS. THESE ARE TO BE REFINED IN THE LANDSCAPE PLANS PROVIDED BY LANDSCAPE ARCHITECT true north DATE REV. BY DESCRIPTION 8:12 8:12 8:12 6" 6" 15:12 PROP BEAM + OVERFRAME ROOF ABOVE 3.5:12 BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING 15:12 15:12 10:12 10:12 15:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 3'-9" 2'-0" 10:12 7'-1 155/256" PL. HT. 7'-1 1/2" PL. HT. 7'-1 155/256" PL. HT. 7'-1 1/2" PL. HT 5'-8 1/4" PL. HT. 5'-7 31/64" PL. HT. 6'-1 155/256" PL. HT. 4'-6" PL. HT. 7'-1 1/2" PL. HT. 7'-1 1/2" PL. HT. 7'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 7'-1 1/2" PL. HT 9'-1 1/2" PL. HT. 9'-9 1/4" PL. HT. 11'-1 5/8" PL. HT. 5'-7 31/64" PL. HT. 4'-10 53/128" PL. HT. FROM UPPER FLOOR 6'-6 155/256" PL. HT. FROM UPPER LEVEL 6'-6 235/256" PL. HT. 12'-9 21/256" PL. HT. 4'-6" PL. HT. 4'-6" PL. HT. 12'-9 21/256" PL. HT. 8'-0 29/128" PL. HT. 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-10 1/2" PL. HT 7'-10 1/2" PL. HT 7'-10 1/2" PL. HT 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8:12 8:12 8:12 9'-5 1/2" PL. HT. 12'-4 1/2" PLATE HT. 8'-4 1/2" PL. HT. 8'-4 39/64" PL. HT. 8'-4 39/64" PL. HT. 13'-4 1/2" PL. HT. 13'-4 155/256" PL. HT. 10'-6 27/128" PL. HT. 11'-7 155/256" PL. HT. 11'-7 155/256" PL. HT. 11'-7 155/256" PL. HT. 11'-7 1/2" PL. HT. 11'-7 155/256" PL. HT. 11'-7 155/256" PL. HT. 9'-5 1/2" PL. HT. ABOVE MAIN LEVEL 9'-5 155/256" PL. HT. ABOVE MAIN LEVEL 14'-3" PLATE HT. 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 12'-4 1/2" PLATE HT. 9'-5 155/256" PL. HT. 9'-5 155/256" PL. HT. 10'-6" PL. HT. 11'-7 155/256" PL. HT. 9'-5 1/2" PL. HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEV. HIP HIP RIDGE HIP VALLEY HIP RIDGE RIDGE VALLEY HIP HIP VALLEY HIP HIP RIDGE HIP HIP VALLEY VALLEY HIP VALLEY HIP HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE HIP HIP RIDGE VALLEY VALLEY RIDGE VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALL EY VALLEY VALLEY HIP HIP RIDGE RIDGE HIP HIP VALLEY RIDGE VALLEY HIP HIP RIDGE VALLEY CRICKET VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY HIP HIP RIDGE VALLEY VALLEY HIP HIP VALLEY VALLEY HIP HIP VALLEY VALLEY HIP HIP VALLEY VALLEY HIP HIP RIDGE RIDGE HIP HIP VALLEY VALLEY HIP HIP HIP HIP VALLEY VALLEY RIDGE HIP HIP VALLEY VALLEY RIDGE HIP HIP VALLEY VALLEY RIDGE HIP HIP VALLEY VALLEY RIDGE 8'-4 1/2" PL. HT. BARREL VAULT ABOVE FLUSH BEAM FLUSH BEAM FLUSH BEAM DROP OR FLUSH BEAM AS REQ'D DROP OR FLUSH BEAM AS REQ'D FLUSH BEAM FLUSH BEAM 5'-2" PL. HT. 5'-2" PL. HT. 7'-1" PL. HT. 7'-1" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 15:12 5'-2" PL. HT. 5'-2" PL. HT. 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 9" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 3'-9 1/2" PL. HT. 3'-9 1/2" PL. HT. 3'-9 1/2" PL. HT. 3'-9 1/2" PL. HT. RIDGE RIDGE MIN. 10" MAX. 7 5/8" RISER 3/4" TREAD 1 1/8" TREAD 11 5/16" 11 1/4" (3) 2x12 STRINGERS MIN. 1/2" DRYWALL VAPOR BARRIER BATT INSULATION 3/4" SPRAY FOAM INSULATION 1/2" O.S.B. SHEATHING HOUSE WRAP 1" AIR SPACE BRICK/STONE VENEER TOTAL R-VALUE BRICK/STONE R=0.45 R=0.63 R=13 R=4.68 R=0.63 R=0.17 R=1.0 R=0.44 R=21.0 2x8 RAFTER @ 16" O.C. 7/16" DECKING 2x8 C/J @ 16" O.C. BRICK/STONE VENEER (R-0.44) 2x6 RAFTER TAIL 3/8" VENTED SOFFIT BATT INSUL. R-38 ASPHALT SHINGLES 30# FELT 1X6 GUTTER BOARD 1X6 FRIEZE BOARD WEEP HOLES @ 32" O.C. (MAX) 5X5 BRICK LEDGE FLASHING 14" 14" GRADE (4" BELOW STONE LEDGE) 10" POURED CONC. WALL 3/4" SUB-FLOOR R-13 INSULATION 2X6 TREATED PLATE ON FOAM SUB-SILL W/ 1/2" X 10" ANCHOR BOLTS @ 5'-0" O.C., 1'-0" FROM CORNERS 10 YR. WARRANTY WATERPROOFING W/ 3/8" BOARD (RUBBER SPRAY) #6 VERT. REBAR @ 2'-0" O.C. PEA GRAVEL 24" ABOVE DRAIN TILE 4" DIA. DRAIN TILES "U" BARS W/ 6"-8" PROJECTION @ 8'-0" O.C. 21" X 8" CONT. CONC. FTG. W/ (2) #5 REBAR CONT. 3/4" SUB-FLOOR R-13 INSULATION #5 HORIZ. REBAR 1 R0W: 3'-0" WALL 5 ROWS: 9'-0" WALL 6 ROWS: 10'-0" WALL 1/2" DRYWALL R-0.45 2X6 STUDS @ 16" O.C. VAPOR BARRIER R-0.63 3 1/2" BATT INSUL. R-13 3/4" SPRAY FOAM INSUL. R-4.68 1/2" O.S.B. SHEATHING R-0.63 "TYPAR" OR EQ. HOUSE WRAP R-0.17 1" AIR GAP 1'-4" 1" AIR GAP (R=1.0) VENEER TIES (TIE SPACING AS PER INTERNATIONAL RESIDENTIAL CODE 2x8 RAFTER @ 16" O.C. 7/16" DECKING 2x8 C/J @ 16" O.C. 2x4 RAFTER TAIL 3/8" VENTED SOFFIT BATT INSUL. R-38 ASPHALT SHINGLES 30# FELT 1X6 GUTTER BD. 1X6 FRIEZE BOARD 1'-4" 8 12 15 12 1'-4 113/256" 2x8 RAFTER @ 16" O.C. 7/16" DECKING 2x8 C/J @ 16" O.C. 2x4 RAFTER TAIL 3/8" VENTED SOFFIT BATT INSUL. R-38 ASPHALT SHINGLES 30# FELT 1X6 FRIEZE BOARD 1'-4" 8 12 10 12 1'-4 113/256" 1X6 GUTTER BD. 2x8 RAFTER @ 16" O.C. 7/16" DECKING 2x8 C/J @ 16" O.C. 3/8" VENTED SOFFIT BATT INSUL. R-38 ASPHALT SHINGLES 30# FELT 1X6 GUTTER BOARD 1X4 FRIEZE BOARD 1'-0" 10 12 10 7/16" 2x8 RAFTER @ 16" O.C. 7/16" DECKING 2x8 C/J @ 16" O.C. 3/8" VENTED SOFFIT BATT INSUL. R-38 ASPHALT SHINGLES 30# FELT 1X4 TRIM BOARD (NO GUTTER) 1X4 FRIEZE BOARD 10 12 2x4 RAFTER TAIL 9" 6 1/4" 2x8 RAFTER @ 16" O.C. 7/16" DECKING 2x8 C/J @ 16" O.C. 3/8" VENTED SOFFIT BATT INSUL. R-38 ASPHALT SHINGLES 30# FELT 1X4 TRIM BOARD (NO GUTTER) 1X4 FRIEZE BOARD 10 12 2x4 RAFTER TAIL 6" 3 3/4" DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:09 PM Carmel, IN 46032 1095 Laurelwood ROOF PLAN 6 STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET 1/4" = 1'-0" ROOF PLAN ALL OVERHANGS TO BE 12" O.H. FROM FRAME AT SIDING AND 16" FROM FRAME AT BRICK U.N.O. SIZES OF ROOF RAFTERS AND CEILING JOISTS AND SPACING PER STRUCT. ENG. PROVIDE SOLID BLOCKING BELOW ALL KNEEWALLS AND OVERFRAMING PER TRUSS MFR. AND STRUCT ENG. !! ATTENTION !! NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER TO COORDINATE THE INSTALLATION OF ALL WATER PROOFING METHODS NECESSARY TO PROVIDE A WATER TIGHT BUILDING ENVELOPE. REFER TO MFR. INSTALLATION RECOMMENDATION FOR ALL SELECTED WATERPROOFING MATERIALS, FLASHING, SEALERS AND AD-MIX COMPONENTS THE FRAMING PLANS REPRESENTED IN THESE DRAWINGS ARE INTENDED TO ESTABLISH PROPOSED FRAMING MEMBER LOCATIONS, FRAMING MEMBER DEPTH, POTENTIAL BEARING LOCATIONS AND ELEVATIONS, AND IS IN NO WAY INTENDED OR TO BE INTERPRETED AS STRUCTURAL ENGINEERED DRAWINGS. THE CONTRACTOR (BUILDER)SHALL ENSURE THAT THE STRUCTURE CONFORMS TO THOSE STRAINS, LOADS, CONNECTIONS, AND STABILITY. REFER TO PLAN DISCLAIMER LOCATED ON THIS SHEET FOR ADDITIONAL STIPULATIONS AND REQUIREMENTS. Framing PLAN DISCLAIMER ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER project north true north 1/2" = 1'-0" TYPICAL INTERIOR STAIR DETAIL 1/2" = 1'-0" TYPICAL WALL SECTION - BRICK/STONE 1/2" = 1'-0" 15-12 W/ 8-12 TAIL 1/2" = 1'-0" 10-12 W/ 8-12 TAIL 1/2" = 1'-0" 10-12 W/ 12" OH (BRICK DORMERS) 1/2" = 1'-0" 10-12 W/ 9" OH + NO GUTTER (TYP DORMER) TYPICAL OVERHANG DETAILS (MAIN ROOFLINES) DORMER OVERHANG DETAILS 1/2" = 1'-0" 10-12 W/ 9" OH + NO GUTTER (DET. GARAGE) DATE REV. BY DESCRIPTION 18'-8" 2'-11" 4'-0" 6'-1" 5'-2 1/2" 3'-11 1/2" 9'-6 1/2" 6'-1 155/256" PL. HT. 4'-6" PL. HT. 3'-1" 7'-7" 3'-1" 13'-9" 7'-1 1/2" PL. HT. 7'-1 1/2" PL. HT. 7'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 4'-0" 4'-0" 6'-5 1/2" 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 9'-1 1/2" PL. HT. 7'-1 1/2" PL. HT 9'-1 1/2" PL. HT. 9'-9 1/4" PL. HT. 11'-1 5/8" PL. HT. 5'-7 31/64" PL. HT. 4'-10 53/128" PL. HT. FROM UPPER FLOOR 6'-6 155/256" PL. HT. FROM UPPER LEVEL 69'-3 1/2" 6'-6 235/256" PL. HT. 12'-9 21/256" PL. HT. 22'-3" 13'-9" 3'-9" 7'-6" 3'-9" 14'-1 1/2" 16'-10" 18'-9" 106'-0" 2'-0" 6'-0" 2'-4" 6'-6" 3'-10" 6'-6" 9'-6 1/2" 17'-7" 4'-6" PL. HT. 4'-6" PL. HT. 12'-9 21/256" PL. HT. Unheated Storage 2x6 BEARING WALL 2x6 BEARING WALL 2x4 BEARING WALL 2x6 BEARING WALL 2x6 BEARING WALL 18 R@ 7 73/128" 18 R@ 7 73/128" 19'-10 1/4" 2'-5 1/2" FINISHED WALL TO CL DOOR 8'-0 29/128" PL. HT. FLUSH BEAM FLUSH BEAM FLUSH BEAM DROP OR FLUSH BEAM AS REQ'D DROP OR FLUSH BEAM AS REQ'D FLUSH BEAM FLUSH BEAM VAULTED DORMER ABOVE VAULTED DORMER ABOVE VAULTED DORMER ABOVE VAULTED DORMER ABOVE VAULTED DORMER ABOVE Bath 5 Bath 4 WIC 4 WIC 5 WIC 2 Bath 2 WIC 3 Bath 3 9'-1 1/2" CEILING SLOPED CEILING VAULTED DORMER ABOVE VAULTED DORMER ABOVE BARREL VAULT ABOVE BARREL VAULT ABOVE SLOPE CLG TO FOLLOW ROOF OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING 8'-1 1/2" CLG 9'-1 1/2" CLG HT. 9'-1 1/2" CLG 9'-1 1/2" CLG 8'-1 1/2" CLG OPEN TO ABOVE, VAULTED CEILING V48 V48 V48 V48 3068 2668 2868 2668 2668 2868 2248 3068 Cased Opening 2868 (2)2668 2668 3068 2668 2868 2468 2668 2668 3068 CABINET BENCH CABINET BENCH FULL WOOD TREADS W/ CARPET RUNNER FULL WOOD TREADS W/ CARPET RUNNER CARPET TILE TILE CARPET CARPET CARPET TILE CARPET CARPET CARPET CARPET CARPET CARPET TILE CARPET 3'-1 1/2" 4'-10" 6" 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 5'-6" 9'-2 1/2" 4'-6" 7'-10 1/2" PL. HT 7'-10 1/2" PL. HT 7'-10 1/2" PL. HT 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 8'-7 1/2" PL. HT. 3'-4 1/2" 3'-4 1/2" 106'-0" 2'-0" 2'-0" 3'-1 1/2" 3'-1 1/2" 3'-3" 3'-3" 2'-8" 3'-3" 3'-3" 9'-2" 4'-6" 4'-0" 10'-5" 9'-5" 9'-3" 5'-5 1/2" 3'-8" 13'-6" 4'-5 1/2" 10'-0 1/2" 2'-5" 4'-8" 7 1/2" 9'-4" 5'-1" 3 1/2" 4'-1" 9'-2 1/2" 14'-6" 2'-5" 5'-6" 7'-11" 2'-9" 12'-4 1/2" 5'-10" 6" 2'-10 1/2" 13'-0" 2'-10 1/2" 6" 2'-4" 6 1/2" 4'-2 1/2" 4'-11" 5'-1" 2'-6" 11'-8 1/2" 4'-1" 4'-5 1/2" 4'-10" 6'-4 1/2" ALIGN ALIGN 30" x 66" HDR AT 8'-0" (2) CSMT 30" x 66" HDR AT 8'-0" (2) CSMT 30" x 66" HDR AT 8'-0" (2) PICT 29" x 41" HDR AT 6'-8" (2) CSMT 29" x 41" HDR AT 6'-8" (2) CSMT 29" x 41" HDR AT 10'-3" PICT 25" x 53" HDR AT 7'-6" CSMT 29" x 41" HDR AT 6'-8" (2) CSMT 29" x 41" HDR AT 6'-8" (2) CSMT 29" x 41" HDR AT 6'-8" (2) CSMT 29" x 53" HDR AT 7'-6" (2) CSMT 29" x 41" HDR AT 6'-8" (2) CSMT 29" x 41" HDR AT 10'-3" PICT 29" x 41" HDR AT 6'-8" (2) CSMT 9'-1 1/2" CEILING 9'-1 1/2" CLG HT. 9'-1 1/2" CLG 5'-2" PL. HT. 5'-2" PL. HT. 7'-1" PL. HT. 7'-1" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 13'-9" 6'-3" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 6'-3" PL. HT. 3068 28'-5 129/256" + 0'-0" AFF UPPER LEVEL - 1'-6" AFF UPPER LEVEL 5'-2" PL. HT. 5'-2" PL. HT. EQ EQ 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 7'-8" PL. HT 7'-8" PL. HT 7'-10 21/256" PL. HT 3'-9 1/2" PL. HT. 3'-9 1/2" PL. HT. 3'-9 1/2" PL. HT. 3'-9 1/2" PL. HT. 27" x 33" HDR AT 3'-0" PICT 27" x 33" HDR AT 3'-0" PICT 27" x 33" HDR AT 3'-0" PICT 27" x 33" HDR AT 3'-0" PICT 8'-10" 3'-2" 2'-6" 16'-6" 8'-0 1/2" Unheated Storage Kids' Loft OPEN TO ABOVE, VAULTED CEILING OPEN TO ABOVE, VAULTED CEILING 3068 10'-8 1/2" 10'-8 1/2" "Y" "X" "Z" "W" WALLS WALL LEGEND 2 X 6 FRAME WALL 2 X 4 FRAME WALL 10" CONCRETE FOUNDATION WALL 2 X 4 STUDS TURNED SIDEWAYS TO FUR RADIUS GENERAL NOTES: -WINDOW SUPPLIER TO VERIFY ALL WINDOW SIZING PRIOR TO ORDER -CONCRETE WALLS DRAWN AS 10" THICK W/ 5" STONE/BRICK LEDGE -EXTERIOR 2X6 WALLS DRAWN AS 6.5" THICK (INCL. 1/2" SHEATHING + 1/2" DRYWALL) WITH EXTERIOR MATERIAL SHOWN BEYOND -INTERIOR 2X4 WALLS DRAWN AS 4.5" THICK (INCL. 1/2" DRYWALL BOTH SIDES). IF ADJ. TO FOUNDATION WALL OR UNHEATED STORAGE, SHOWN AS 4" THICK (DRYWALL ON ONE SIDE) -INTERIOR 2X6 WALLS DRAWN AS 6.5" THICK (INCL. 1/2" DRYWALL BOTH SIDES). IF ADJ. TO FOUNDATION WALL OR UNHEATED STORAGE, SHOWN AS 6" THICK (DRYWALL ON ONE SIDE) -BUILDING/GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEETING AND CONFORMING TO CURRENTLY ADOPTED IRC, STATE, AND LOCAL BUILDING CODES -BUILDING/GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION MEETING AND CONFORMING TO THE 2009 EICC AND 2012 INDIANA RESIDENTIAL ENERGY CODES -ALL BEAMS, LOADS, FOOTINGS, AND STRUCTURAL COORDINATION TO BE THE SOLE RESPONSIBILITY OF THE BUILDING/GENERAL CONTRACTOR -ALL 2X6 FRAME WALLS OVER 18'-0" IN HEIGHT MUST BE BUILT IN ACCORDANCE TO LOCAL AND GOV'T CODES TO ENSURE STRUCTURAL INTEGRITY FOR RESISTING WIND LOADS -APPLY POLYURETHANE SPRAY FOAM INSULATION TO ALL FACES AND FILL INSIDE OF H.S.S. THAT PENETRATE HEATING ENVELOPE 1/4" = 1'-0" UPPER LEVEL FLOOR PLAN DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:06 PM Carmel, IN 46032 1095 Laurelwood UPPER LEVEL FLOOR PLAN 5b STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET 2,534 sf heated 294 sf unheated storage project north true north DATE REV. BY DESCRIPTION Dining Mud Room (4) LOCKERS - GIRLS MOM'S LOCKER 4'-4 1/2" 7'-0 1/2" LAUNDRY CHUTE CEILING SLOPED FOR STAIR ABOVE HOMEWORK COUNTER WASHER SPACE DRYER SPACE DAD'S LOCKER BENCH Great Room Foyer 2'-10" Hearth FIREPLACE FURNITURE FURNITURE Garage - Detached BENCH 9'-5 1/2" 3'-10" 3 1/2" 5'-11 1/2" WALK-IN SHOWER 3'-6 1/4" 3'-9 3/4" 5'-11 1/2" 5'-9" 9'-4 1/2" 5 1/2" 19'-6" 16'-9" 3'-9" 6'-0" 6'-0" 3'-5 1/2" 5'-1" Pantry 4'-1" 3 1/2" 11'-1 1/2" 3 1/2" 18'-6 1/2" Covered Patio 2'-0" 18'-0" 2'-3" 18'-0" 2'-0" 4'-6" 6'-6" 4'-6" EQ EQ 27'-9" 4'-0" 21'-3" 18'-11" 3'-1 1/2" 15'-0" 3'-1 1/2" 3'-10" 1'-1 1/2" 8'-11 1/2" 5 1/2" 5'-11" 5 1/2" 24'-11 1/2" 15'-9" 6'-3" 3'-3" 3'-0" 2'-6" 2'-0" 5'-4 5/8" 8'-0" Play House 2'-1" 14'-6" 3 1/2" 4'-6" 9'-3" 8'-0 1/2" 4'-1" 8'-1 1/2" 4'-1" FISH TANK *INCLUDE HEAT AND AC IN GARAGE TUB: KOHLER K-1166-RE-0 His W.I.C. 48" GRILL 2'-8" FIREPLACE 6'-0" 5'-0" HALF-HT WALL HALF-HT WALL CASED OPENING W/ RADIUS TOP HEADER 4'-7 1/4" 10'-0 1/4" 5'-5 3/4" 12'-10 1/2" 6'-9 1/2" 6'-9 1/2" 3'-9" 11'-8" 10'-7 1/2" 9'-6 1/2" 3'-5" 9'-5 1/2" PL. HT. 12'-4 1/2" PLATE HT. 8'-4 1/2" PL. HT. 8'-4 39/64" PL. HT. 8'-4 39/64" PL. HT. 6'-9" 6'-9" 6'-6" 6'-6" 13'-4 1/2" PL. HT. 13'-4 155/256" PL. HT. 13'-4 1/2" PL. HT. 13'-4 1/2" PL. HT. 13'-4 155/256" PL. HT. 10'-6 27/128" PL. HT. 11'-7 155/256" PL. HT. 11'-7 155/256" PL. HT. 11'-7 155/256" PL. HT. 11'-7 1/2" PL. HT. 11'-7 155/256" PL. HT. 11'-7 155/256" PL. HT. 9'-5 1/2" PL. HT. ABOVE MAIN LEVEL 9'-5 155/256" PL. HT. ABOVE MAIN LEVEL 14'-3" PLATE HT. 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 2'-11" 8'-3" 11'-3" 8'-3" 22'-7" 22'-3" 6 1/2" 20'-2" 6 1/2" 3'-1 1/2" 15'-0" 3'-1 1/2" 6'-3" 5'-2" 122'-6" 140'-7" 2'-8" 3'-9" 9'-3" Swimming Pool 2'-0" 14'-4 1/2" 3 1/2" 12'-5 1/2" 16'-5 1/2" 16'-0" 1'-0" 4'-3" 3'-9" 2'-3" FIREPLACE 122'-6" EQ EQ 3'-8" 5'-1 1/2" 3'-8" 6'-9" 8'-9" 6'-8" *INCLUDE HEAT AND AC IN GARAGE 21'-6" 16'-5" 9'-6 1/2" 27'-9" 4'-0" 21'-3" 16'-10" 42'-3" 13'-9" 14'-9" 2'-5" 2'-5" PLANTING AT DRIVEWAY GRADE PLANTING AT DRIVEWAY GRADE RAISED PLANTER AND/OR FOUNTAIN FEATURE 2' BRICK WALL W/ LIMESTONE CAP 2' BRICK WALL W/ LIMESTONE CAP 3'-4" DIVING BOARD 7'-0" 40'-0" 13'-10 1/2" 73'-0" 4'-6" 6'-6" 4'-6" 6'-6" 5'-8" 3'-9" 6'-4 1/2" 8'-6" 2'-3" 2x6 BEARING WALL 2x6 BEARING WALL 2x4 BEARING WALL 2x6 BEARING WALL 2x6 BEARING WALL 6'-9 1/2" COUNTER 18 R@ 7 73/128" 18 R@ 7 73/128" 4 R@ 6" 4 R@ 6" 18 R@ 7 73/128" 18 R@ 7 89/256" 4 R@ 6" 4 R@ 6" 4 R@ 6" 2'-6" 4'-5" 2'-3" 2'-5 1/2" FINISHED WALL TO CL DOOR FINISHED WALL TO CL DOOR ZERO THRESH. SHOWER. DROP SH. FLOOR AS REQ. 12'-4 1/2" PLATE HT. 9'-5 155/256" PL. HT. 9'-5 155/256" PL. HT. 13'-4 155/256" PL. HT. 10'-6" PL. HT. 11'-7 155/256" PL. HT. 9'-5 1/2" PL. HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 11'-7 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEVEL 10'-1 1/2" PLATE HT. ABOVE MAIN LEV. 10'-1 1/2" CLG HEIGHT FLUSH BEAM FLUSH BEAM DROP BEAM VAULTED CEILING, FUR DOWN ROOFLINE BARREL VAULT ABOVE 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CEILING 10'-1 1/2" CLG HT. DOUBLE FRAMED 2X6 + 2X4 WALLS APPROX. 4'-10" HT. FIN. CLG BELOW LANDING DROP BEAM 3'-3" 2'-2" 3'-9 1/2" DROP OR FLUSH BEAM AS REQ'D DROP OR FLUSH BEAM AS REQ'D FLUSH BEAM DROP BEAM, HT AFF TBD FLUSH BEAM FLUSH BEAM FLUSH BEAM FLUSH BEAM FLUSH BEAM DROP BEAM DROP OR FLUSH BEAM AS REQ'D 10'-1 1/2" CEILING CEILING VAULTED ABOVE STAIRS 10'-1 1/2" CEILING Hallway Hallway 10'-1 1/2" CEILING OPEN TO ABOVE VAULTED DORMER ABOVE VAULTED DORMER ABOVE OPEN TO ABOVE 10'-1 1/2" CEILING WIC PLAY 10'-1 1/2" CLG HT 10'-1 1/2" CLG HEIGHT OPEN TO ABOVE, VAULTED CEILING, W/ 10X10 COLLAR TIES AT 13' AFF 10'-1 1/2" CLG HT. 10'-1 1/2" CLG HT. VAULTED CEILING ABOVE V54 V54 V54 K-6427-0 16'-9 1/2" 48" RANGE 30" FREEZER, PANEL READY 30" FRIDGE / FREEZER V42 2880 Cased Opening 2480 PKT (2)3080 Cased Opening 3080 2680 2880 2680 PKT 3080 3080 (2)3080 Cased Opening (2)2680 2880 3068 180120 180120 18080 18080 (2)2680 2680 Cased Opening 2680 3080 3068 Cased Opening (2)2880 2880 Cased Opening 3080 3080 3080 3680 2480 18080 3680 14480 2880 6" 3'-1" 2880 2680 2880 2680 LINEAR DRAIN AT EXT. WALL 30" FRIDGE PANEL READY DW W/ HEAT, PANEL READY 12'-6" THIN BRICK FLOORING (STRAIGHT SET PERIMETER W/ INSET HERRINGBONE) HARDWOOD TO THIN BRICK FLOOR TRANSITION 8'-6" SOFFIT 8'-6" SOFFIT DROP OR FLUSH BEAM AS REQ'D FLUSH BEAM 8X8 COFFERED BEAMS ABOVE 8X8 COFFERED BEAMS ABOVE FULL-HT THIN BRICK SURROUND FULL-HT THIN STONE SURROUND CABINET BENCH 4'-6" 5'-9" HVAC CLOSET BUILT-IN SEHLVES BUILT-IN SEHLVES TILE HARDWOOD HARDWOOD HARDWOOD HARDWOOD HARDWOOD HARDWOOD CARPET HARDWOOD TILE CARPET TILE TILE TILE TILE HARDWOOD HARDWOOD HARDWOOD CARPET TILE FULL WOOD TREADS W/ CARPET RUNNER FULL WOOD TREADS W/ CARPET RUNNER CARPET STAIRS DW W/ HEAT, PANEL READY EXTERIOR FACE OF SHEATHING INTERIOR FACE OF FRAMING 2'-11" INTERIOR FACE OF FRAMING EXTERIOR FACE OF SHEATHING 4'-10 1/2" 18'-0" 4'-10 1/2" 21'-3" 3080 2'-5" 9'-8" 5'-5 1/2" 2'-5" 140'-7" OVERALL FOOTPRINT, EXT. FACES OF SHEATHING 5'-4 1/2" 8'-10 1/2" 8'-10 1/2" 3'-9" 5'-0" 4'-2" 4'-1 1/2" 8'-4" 6'-9 1/2" 6'-9 1/2" 4'-2" 4'-2 1/4" 11'-4 1/2" 3'-7 3/4" 8'-6" 8'-6" 3'-6" 21'-11" 7'-5" 2'-6" 7'-0 1/2" 1'-2 1/2" 10'-4" OVERALL FOOTPRINT, EXT. FACES OF SHEATHING 6'-11" EXTERIOR FACE OF SHEATHING 1'-1" 2'-9" 3 1/2" 4'-10" TO BEAM 8'-2 1/2" 4'-3" 3 1/2" 3'-11 1/2" 5 1/2" 3'-2 1/2" 2050 9'-1 1/2" 10'-8 1/2" 10'-4" 8'-1" 6'-8 1/2" 5'-10 1/2" 12'-7" 4'-9" BEAM TO BEAM 5'-6" 7'-1" 5'-6" 6'-7" 11'-4" 7'-0 1/2" 13'-3 1/2" 4'-6" 3'-8" 1'-10 1/2" 3'-10" 5'-8 1/2" 10'-2 1/2" 1'-6" 2'-9" 9'-1 1/4" 135° 135° 4'-6" 6'-1" 2'-4" 3'-5 1/2" 12'-0" 12'-11 1/2" 5'-7" 3'-11" 28'-5" 16'-3 1/2" 7'-10" 2'-3" 2'-3" 3'-0" ALIGN ALIGN ALIGN ALIGN 4'-2" 4'-2" 36" x 78" HDR AT 7'-6" PICT 36" x 78" HDR AT 7'-6" PICT 35" x 73" HDR AT 8'-0" (3) PICT 35" x 73" HDR AT 8'-0" PICT 35" x 73" HDR AT 8'-0" PICT 35" x 53" HDR AT 7'-11" PICT 36" x 78" HDR AT 7'-6" PICT 36" x 78" HDR AT 7'-6" PICT 25" x 65" HDR AT 7'-0" (2) PICT 25" x 65" HDR AT 7'-0" (2) PICT 29" x 65" HDR AT 7'-8" (2) PICT 35" x 73" HDR AT 9'-0" CSMT 30" x 48" HDR AT 8'-0" OVAL 35" x 73" HDR AT 8'-0" (2) CSMT 35" x 17" HDR AT 8'-5" (2) TRANS 35" x 53" HDR AT 7'-11" PICT 35" x 73" HDR AT 7'-6" CSMT 35" x 73" HDR AT 7'-6" CSMT 35" x 73" HDR AT 8'-0" (2) CSMT 35" x 17" HDR AT 8'-5" (2) TRANS 35" x 73" HDR AT 7'-6" PICT 35" x 73" HDR AT 9'-0" CSMT 35" x 73" HDR AT 9'-0" PICT 58" x 15" HDR AT 8'-11" TRANS 36" x 18" HDR AT 9'-0" TRANS 36" x 18" HDR AT 9'-0" TRANS 36" x 18" HDR AT 9'-0" TRANS 36" x 18" HDR AT 9'-0" TRANS 105" x 35" 105" x 33" HDR AT 10'-3" TRANS 35" x 17" HDR AT 9'-5" (2) TRANS 35" x 17" HDR AT 9'-5" TRANS 35" x 17" HDR AT 9'-5" TRANS 32" x 17" HDR AT 9'-5" ? 35" x 17" HDR AT 9'-5" TRANS 35" x 17" HDR AT 9'-5" TRANS 35" x 17" HDR AT 9'-5" TRANS 35" x 17" HDR AT 9'-5" TRANS 35" x 65" HDR AT 7'-0" (2) PICT 35" x 65" HDR AT 7'-0" (2) PICT CAP 1/2 HT BRICK WALL W/ LIMESTONE CAP CAP 1/2 HT BRICK WALL W/ LIMESTONE CAP 10x10 POST TO SUPPORT ROOF ABOVE 10x10 POST TO SUPPORT ROOF ABOVE AC UNIT AC UNIT AC UNIT AC UNIT AC UNIT 10'-1 1/2" CLG HT 8'-4 1/2" PL. HT. BARREL VAULT ABOVE 8'-6" HEADER AFF 5'-6 5/8" 7 1/4" 5'-6 5/8" 1'-10 3/8" POOL EQUIPMENT LOCATION 7'-4" 2'-5" 2'-5" 5'-4 1/8" MICRO + PLUMBED COFFEE POT FILLER INCL. SMALL SINK + WATER DISPENSER, LOCATION TBD 12'-1 1/2" CEILING 10'-7 1/2" CEILING VAULTED CEILING ABOVE 2" 3'-9" 7'-6" 4'-5" 2'-11" 2'-6" 4'-4" EQ EQ 3'-10 1/2" ENCLOSED WITHIN CABINETS 5'-7" 4'-0 1/2" DUTCH DOOR FURN. MIRROR RECESSED TV BEHIND MIRROR, THIS VANITY ONLY TOE KICK VACUUM TOE KICK VACUUM TOE KICK VACUUM TOE KICK VACUUM TOE KICK VACUUM WHOLE HOUSE VACUUM CANISTER 3'-6" WALL LEGEND 2 X 6 FRAME WALL 2 X 4 FRAME WALL 10" CONCRETE FOUNDATION WALL 2 X 4 STUDS TURNED SIDEWAYS TO FUR RADIUS GENERAL NOTES: -WINDOW SUPPLIER TO VERIFY ALL WINDOW SIZING PRIOR TO ORDER -CONCRETE WALLS DRAWN AS 10" THICK W/ 5" STONE/BRICK LEDGE -EXTERIOR 2X6 WALLS DRAWN AS 6.5" THICK (INCL. 1/2" SHEATHING + 1/2" DRYWALL) WITH EXTERIOR MATERIAL SHOWN BEYOND -INTERIOR 2X4 WALLS DRAWN AS 4.5" THICK (INCL. 1/2" DRYWALL BOTH SIDES). IF ADJ. TO FOUNDATION WALL OR UNHEATED STORAGE, SHOWN AS 4" THICK (DRYWALL ON ONE SIDE) -INTERIOR 2X6 WALLS DRAWN AS 6.5" THICK (INCL. 1/2" DRYWALL BOTH SIDES). IF ADJ. TO FOUNDATION WALL OR UNHEATED STORAGE, SHOWN AS 6" THICK (DRYWALL ON ONE SIDE) -BUILDING/GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEETING AND CONFORMING TO CURRENTLY ADOPTED IRC, STATE, AND LOCAL BUILDING CODES -BUILDING/GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION MEETING AND CONFORMING TO THE 2009 EICC AND 2012 INDIANA RESIDENTIAL ENERGY CODES -ALL BEAMS, LOADS, FOOTINGS, AND STRUCTURAL COORDINATION TO BE THE SOLE RESPONSIBILITY OF THE BUILDING/GENERAL CONTRACTOR -ALL 2X6 FRAME WALLS OVER 18'-0" IN HEIGHT MUST BE BUILT IN ACCORDANCE TO LOCAL AND GOV'T CODES TO ENSURE STRUCTURAL INTEGRITY FOR RESISTING WIND LOADS -APPLY POLYURETHANE SPRAY FOAM INSULATION TO ALL FACES AND FILL INSIDE OF H.S.S. THAT PENETRATE HEATING ENVELOPE DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:04 PM Carmel, IN 46032 1095 Laurelwood MAIN LEVEL FLOOR PLAN 5a STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET 1/4" = 1'-0" MAIN LEVEL FLOOR PLAN VERIFY ALL WDW & DR ROUGH OPNGS W/ MFR SPECS. SEE PLAN FOR WDW HDR HTS. ALL POCKET DOOR FRAMES TO BE SHEATHED WITH OSB. VERIFY DEPTH AND WIDTH OF SLAB RECESS AT ALL DOORS TO ACCOMMODATE PROPER ALIGNMENT WITH THRESHOLDS AND DOOR TRACKS WITH MFR. REQUIREMENTS IN RELATION TO FINISH FLOOR MATERIALS. REC CLG SURFACES, BOTH HORIZONTAL AND VERTICAL, SHALL HAVE SMOOTH FIN. SEE SHEET 6 FOR SPECIFIC ELEV DETAILS. GENERAL NOTES: !! ATTENTION !! NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER TO COORDINATE THE INSTALLATION OF ALL WATER PROOFING METHODS NECESSARY TO PROVIDE A WATER TIGHT BUILDING ENVELOPE. REFER TO MFR. INSTALLATION RECOMMENDATION FOR ALL SELECTED WATERPROOFING MATERIALS, FLASHING, SEALERS AND AD-MIX COMPONENTS 4,078 heated SF project north true north DATE REV. BY DESCRIPTION CLASSIC STANDING 25" x 42" CLASSIC STANDING 25" x 42" 3'-5 1/2" 13'-4" 18'-0" 3 1/2" 23'-10 1/2" 3'-11" 1955 CHEVY 3100 PICKUP TRUCK 6'-3" 15'-11 77/256" ELEVATED SCREEN W/ LANDSCAPING BELOW RACE CAR GAME 41" x 63" RACE CAR GAME 41" x 63" SOUNDPROOFING AT PERIMETER OF THEATER WALLS,TYP. 9'-9" CLG HEIGHT 4'-0" 16'-8 1/2" 10" 5'-0" 10" 13'-1 1/2" 10" 28'-7" 3'-2 1/2" 22'-0" 16'-0 1/2" 43'-1" 13'-9" 14'-4" 10" 4'-6" 4'-2" 10" 2'-6" 4'-8" 6'-3" SKEE BALL 30"W x 120"L x 84"H Unexcavated EPOXY FINISH ON CONCRETE FLOOR WALL SHELVING W/ LIQUOR DISPLAY SKEE BALL 30"W x 120"L x 84"H MEGA STACKER LITE 67"W x 50"D x 109"H 141'-0" Soda Fountain Lower Bath Unexcavated 2 1/2" 10" AIR GAP 1" AIR 10" 24'-8 1/2" 10" GAP 10" 5'-2" 10" 1" 3 1/2" 9'-6" 7'-5" 10" 6 1/2" FOOTING + FOUNDATION JOG 1'-4" 2'-4 1/2" 10" 15'-7" 10" 2'-4 1/2" 1'-4" 1'-4" 19'-4" 1'-4" 10" 5'-1 1/2" 10" 2x6 BEARING WALL W/ FOOTINGS + PADS 2x6 BEARING WALL 2x4 BEARING WALL 2x4 BEARING WALL 24'-8" 3 1/2" 1" AIR GAP AIR GAP 8'-6" 3 1/2" 2x4 STUDS TURNED SIDEWAYS 18 R@ 7 73/128" 18 R@ 7 89/256" 10" 3'-2" 10" Unexcavated Unexcavated Unexcavated 4" CONCRETE SLAB ABOVE 4" CONCRETE SLAB ABOVE 4" CONCRETE SLAB ABOVE 4" CONCRETE SLAB ABOVE 4" CONCRETE SLAB ABOVE 4" CONCRETE SLAB ABOVE Unexcavated 2'-6" 10" 6'-2" 1'-9" WIDTH FOOTING AT 10" FOUND. WALLS WIDTH FOOTING AT 10" FOUND. WALLS 1'-9" 1 1/2" FOOTING + FOUNDATION JOG FOOTING + FOUNDATION JOG 2'-3" 2'-3" FOOTING FOOTING FOUND. FOUND. FOUND. 1'-4" FOUND. FOUND. FOUND. 10" 26'-11" 4'-6 1/2" 10" 19'-4" 10" FOUND. INSIDE FACES OF FOUNDATION WALLS FOUND. 1'-4" INSIDE FACES OF FOUNDATION WALLS 2'-4 1/2" 2'-11" 10" 15'-7" 10" 2'-11" 2'-4 1/2" 10" 21'-5" 10" FOUND. INSIDE FACES OF FOUNDATION WALLS INSIDE FACES OF FOUNDATION WALLS INSIDE FACES OF FOUNDATION WALLS 4" CONCRETE SLAB ABOVE Unexcavated 2'-5 1/2" 2'-8" INT. FOUNDATION TO CL DOOR 1'-4" WIDTH FOOTING AT INTERIOR BEARING WALLS WIDTH FOOTING AT INTERIOR BEARING WALLS 1'-4" 9'-9" CLG HEIGHT APPROX. 8'-6" CLG HT. 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT OPEN TO ABOVE 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT 9'-9" CLG HEIGHT 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" FLUSH STEEL BEAM, DRILL HOLES FOR HVAC FLUSH OR DROP BEAM FLUSH OR DROP BEAM FLUSH BEAM DROP BEAM DROP BEAM DROP BEAM 3'-6" 3'-6" 3'-6" 8'-3 1/4" 2x4 BEARING WALL W/ FOOTINGS + PADS HSS STEEL POST, SIZE TBD HSS STEEL POST, SIZE TBD FISH TANK ABOVE W/ STEEL BASE, STRENGTHEN CEILING ABOVE AND ADD POSTS AS REQ'D, TBD IF STEEL IS REQ'D GLASS DISPLAY CABINETS FOR PRIZES W/ GLASS TOP AND BACK WALL SHELVING 24" SMEG FRIDGE 2'-2" 4'-0" FAUX 4-HEAD SODA FOUNTAIN BAR SINK FREESTANDING POPCORN MACHINE OLD SCHOOL STAINED WOOD PANELING, INSET MIRRORS W/ PRINTED GRAPHICS U.C. MICRO Cased Opening Cased Opening 2868 3068 3068 2868 3068 V60 2'-6" HINGED COUNTER FOR ACCESS TO THE BACK HIDDEN DOOR BEHIND OVERSIZED POSTER TILE FLOORING TILE FLOORING CARPET FLOORING REINFORCE FLOOR, OVERSIZED TUB ABOVE BEAMS FOR FIREPLACE ABOVE BEAMS FOR FIREPLACE ABOVE FLUSH BEAM EPOXY FLOOR CARPET CARPET CARPET TILE CARPET FULL WOOD TREADS W/ CARPET RUNNER CARPET STAIRS 17'-7 1/2" 3 1/2" 1" 10" 1" 3 1/2" 4'-5" 10'-1" HIGH SECURITY BIOMETRIC SYSTEM 5'-0 1/2" 8'-0" FACE PLACE PIX PHOTO BOOTH 44" x 63" x 69.5" 2x4 BEARING WALL 14480 ELECTRIC LIFT CABINET FOR GUNS 1'-3 1/2" 2'-0 1/2" 8'-10" 4'-4 1/2" 6'-0 1/2" 10" 29'-6" 10" 4'-2" 10" 17'-9" 12'-1" 30'-2 1/2" 16'-8" 141'-0" 1'-4" 2'-5" 3'-3" 13'-8" 1'-4" 6 1/2" 3'-3" 11'-9 1/2" 28'-7" 3'-6" 15'-0" 3'-6" 2'-3 1/2" 38'-6" 2'-3 1/2" 3'-6" 15'-0" 3'-6" 17'-9 1/2" 1'-6" 2'-6" 10" 6'-8 1/2" 23'-1" exterior FACES OF FOUNDATION WALLS 6'-7 1/2" ext FACE OF garage FOUNDATION 11 1/2" 3'-3" 21'-2 1/2" 10" 4'-3" 13'-6" 17'-9" 8'-8" AIR GAP 4'-9" 19'-2 1/2" 5'-6" 10" 7'-8" 10" 1" 1 1/2" 7'-11 1/2" 3 1/2" 6'-2 1/2" AIR GAP 3'-6" 10'-11" 6" 2'-10 1/2" 6" 2668 6" 3'-0" 6" 1'-9" 10" 2'-3" 4'-5 1/2" 11'-5" 14'-7 1/2" 3 1/2" 21'-5 1/2" 3 1/2" 11'-2" 15'-7" 3 1/2" 4'-3" 2'-7 1/2" 15'-11" R2'-3" 2'-0" 10'-10 1/2" 2'-0" 2'-3" 2'-2" 7280 8'-9 1/2" 15'-0 1/2" 16'-11" 8'-6 1/2" 10'-5 1/2" BEAMBEAM TO BEAM BEAM TO 6'-4 1/2" EQ EQ 5'-1 1/2" HVAC SOFFIT 5'-2" 4'-9" HVAC SOFFIT HVAC SOFFIT DROP SOFFIT DROP SOFFIT DROP SOFFIT EJECT. SUMP SUMP WH WATER LOCATION EJECT. LOCATION WS FD WH FD FURNACE FURNACE TREATED SILL PLATE ON FOUNDATION WALL, TYP TREATED SILL PLATE ON FOUNDATION WALL, TYP TREATED SILL PLATE ON FOUNDATION WALL, TYP STEP FOUNDATION PER GRADE, TYP. STEP FOUNDATION PER GRADE, TYP. STEP FOUNDATION PER GRADE, TYP. STEP FOUNDATION PER GRADE, TYP. 4'-6" 6'-3" 6'-5 1/2" 6'-9" 4'-0 1/2" 2868 VAULT DOOR LOCATE 3'-6" SQ. CONCRETE FOOTING FOR STEEL POST AT SLIDE DROP SOFFIT 2'-1" 3'-5" RACE CAR GAME 41" x 63" RACE CAR GAME 41" x 63" CRANE GAME 36" x 30" x 76" WHAC-A-MOLE 30"W x 28"L FUTURE FUTURE 4'-7" FLUSH BEAM 8'-11" C.L. FL. OUTLET 10'-4" C.L. FLOOR OUTLET FLOOR OUTLET IN SLAB 3068 8'-1 1/2" WALL LEGEND 2 X 6 FRAME WALL 2 X 4 FRAME WALL 10" CONCRETE FOUNDATION WALL 2 X 4 STUDS TURNED SIDEWAYS TO FUR RADIUS GENERAL NOTES: -WINDOW SUPPLIER TO VERIFY ALL WINDOW SIZING PRIOR TO ORDER -CONCRETE WALLS DRAWN AS 10" THICK W/ 5" STONE/BRICK LEDGE -EXTERIOR 2X6 WALLS DRAWN AS 6.5" THICK (INCL. 1/2" SHEATHING + 1/2" DRYWALL) WITH EXTERIOR MATERIAL SHOWN BEYOND -INTERIOR 2X4 WALLS DRAWN AS 4.5" THICK (INCL. 1/2" DRYWALL BOTH SIDES). IF ADJ. TO FOUNDATION WALL OR UNHEATED STORAGE, SHOWN AS 4" THICK (DRYWALL ON ONE SIDE) -INTERIOR 2X6 WALLS DRAWN AS 6.5" THICK (INCL. 1/2" DRYWALL BOTH SIDES). IF ADJ. TO FOUNDATION WALL OR UNHEATED STORAGE, SHOWN AS 6" THICK (DRYWALL ON ONE SIDE) -BUILDING/GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEETING AND CONFORMING TO CURRENTLY ADOPTED IRC, STATE, AND LOCAL BUILDING CODES -BUILDING/GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION MEETING AND CONFORMING TO THE 2009 EICC AND 2012 INDIANA RESIDENTIAL ENERGY CODES -ALL BEAMS, LOADS, FOOTINGS, AND STRUCTURAL COORDINATION TO BE THE SOLE RESPONSIBILITY OF THE BUILDING/GENERAL CONTRACTOR -ALL 2X6 FRAME WALLS OVER 18'-0" IN HEIGHT MUST BE BUILT IN ACCORDANCE TO LOCAL AND GOV'T CODES TO ENSURE STRUCTURAL INTEGRITY FOR RESISTING WIND LOADS -APPLY POLYURETHANE SPRAY FOAM INSULATION TO ALL FACES AND FILL INSIDE OF H.S.S. THAT PENETRATE HEATING ENVELOPE DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:45:01 PM Carmel, IN 46032 1095 Laurelwood LOWER LEVEL FLOOR PLAN 5 STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET 1/4" = 1'-0" LOWER LEVEL FLOOR PLAN 2,811 heated SF project north true north DATE REV. BY DESCRIPTION 15 12 10 12 10 12 194.64 12 194.64 12 8 12 8 12 8 12 15 12 8 12 10 12 10 12 10 12 10 12 10 12 10 12 8 12 10 12 10 12 10 12 8 12 R15'-0 7/16" BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING METAL ROOFING ASPHALT ROOFING WITH LOOK OF BLUE/GREY SLATE ROOF THIN BRICK VENEER AT CHIMNEYS, TYP. LIMESTONE CASED OPENING AT PORTE COCHERE standard red brick siding, typ BRICK HEADER BRICK HEADER BRICK HEADER WINDOWS, PELLA ARCHITECT SERIES, IRON ORE EXT. CLADDING, TYP. solid cedar garage doors w/ similar style, no glass 14" TJI W/ 3/4" SUBFLOOR 14" TJI W/ 3/4" SUBFLOOR & 2x6 sill plate 10 12 10 12 15 12 15 12 MAIN LEVEL 0" UPPER LEVEL 11'-4 1/4" T.O. PL - UPPER LEVEL 20'-5 3/4" APPROX T.O. ROOF 33'-6 101/128" T.O. FOUNDATION -1'-4 1/4" T.O. PLATE 10'-1 1/2" 10 12 15 12 15:12 15:12 15:12 15:12 15:12 15 12 15 12 10 12 15 12 10:12 10:12 10:12 10:12 10:12 15:12 15 12 15 12 10 12 4'-10" HORSE WEATHERVANE ON CUPOLA 10:12 15:12 8:12 8:12 8:12 15:12 8:12 8:12 8:12 8:12 8:12 10 12 8 12 8 12 10 12 10 12 10 12 10 12 8 12 8 12 8 12 8 12 8 12 8 12 8 12 8 12 10 12 10 12 10 12 10 12 R15'-0 7/16" BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING METAL ROOFING 8:12 ASPHALT ROOFING WITH LOOK OF BLUE/GREY SLATE ROOF CEDAR SHAKE SIDING STAINED TO MATCH ROOFING FINISH CEDAR SHAKE SIDING STAINED TO MATCH ROOFING FINISH CEDAR SHAKE SIDING STAINED TO MATCH ROOFING FINISH THIN BRICK VENEER AT CHIMNEYS, TYP. LIMESTONE CASED OPENING AT PORTE COCHERE INSET CEDAR WOOD HEADER W/ RADIUS TOP TO MATCH SHUTTERS CEDAR SHUTTERS STAINED DARK IN SIMILAR HUE AS ROOF, DARKER SHADE, TYP. LIMESTONE SILL BRICK HEADER 1X4 CEDAR TRIM AND DORMER CEDAR SHAKES, STAINED SIMILAR TO ROOF FINISH BRICK HEADER 1X4 CEDAR TRIM AND DORMER CEDAR SHAKES, STAINED SIMILAR TO ROOF FINISH LIMESTONE SILL LIMESTONE SILL INCLUDE PLANTER BOX INCLUDE PLANTER BOX WINDOWS, PELLA ARCHITECT SERIES, IRON ORE EXT. CLADDING, TYP. THIN BRICK VENEER AT CHIMNEYS, TYP. 15 12 15:12 15:12 8 12 DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:44:59 PM Carmel, IN 46032 1095 Laurelwood SIDE ELEVATIONS 2 STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET · FLAT SOFFIT AT PERIMETER OF HOUSE UNLESS NOTED OTHERWISE. · VERIFY ALL WDW & DR ROUGH OPNGS W/ MFR SPECS. · LOCATE ALL PLUMBING STACKS BEYOND THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER CODE. · ROOF VENTS SHOWN FOR LOCATION PURPOSE ONLY. · NUMBER OF ROOF VENTS TO BE DETERMINED BY BUILDER. GENERAL NOTES: !! ATTENTION !! NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER TO COORDINATE THE INSTALLATION OF ALL WATER PROOFING METHODS NECESSARY TO PROVIDE A WATER TIGHT BUILDING ENVELOPE. REFER TO MFR. INSTALLATION RECOMMENDATION FOR ALL SELECTED WATERPROOFING MATERIALS, FLASHING, SEALERS AND AD-MIX COMPONENTS THE FRAMING PLANS REPRESENTED IN THESE DRAWINGS ARE INTENDED TO ESTABLISH PROPOSED FRAMING MEMBER LOCATIONS, FRAMING MEMBER DEPTH, POTENTIAL BEARING LOCATIONS AND ELEVATIONS, AND IS IN NO WAY INTENDED OR TO BE INTERPRETED AS STRUCTURAL ENGINEERED DRAWINGS. THE CONTRACTOR (BUILDER)SHALL ENSURE THAT THE STRUCTURE CONFORMS TO THOSE STRAINS, LOADS, CONNECTIONS, AND STABILITY. REFER TO PLAN DISCLAIMER LOCATED ON THIS SHEET FOR ADDITIONAL STIPULATIONS AND REQUIREMENTS. Framing PLAN DISCLAIMER ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER 1/4" = 1'-0" RIGHT ELEVATION 1/4" = 1'-0" LEFT ELEVATION DATE REV. BY DESCRIPTION 1'-4 1/4" 10'-1 1/2" 1'-2 3/4" 9'-1 1/2" STAINED GLASS WINDOW CUSTOM ORNATE, SOLID WOOD DOORS, DESIGN TBD ORNATE PROFILE LIMESTONE TRIM DETAIL AROUND DOOR + CASED OPENING HORSE WEATHERVANE ON CUPOLA 3'-1" 10:12 10:12 10:12 10:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8:12 8 12 8 12 8 12 15 12 8 12 8 12 8 12 10 12 8 12 15 12 R2'-11 3/4" R2'-6" R4'-6" R4'-11 3/4" R2'-6" R2'-6" R2'-6" R2'-11 3/4" R2'-6" R2'-6" R8'-7 3/16" R10'-0 15/16" R6'-0" R7'-6 1/2" R2'-6" R2'-6" BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING ASPHALTROOFING ROOFING WITH LOOK METAL OF BLUE/GREY SLATE ROOF ASPHALT ROOFING WITH LOOK OF BLUE/GREY SLATE ROOF 5" LIMESTONE TRIM, RAISED PROFILE LIMESTONE SILL LIMESTONE SILL LIMESTONE SILL LIMESTONE SILL WRAP LIMESTONE SIDING INTO ENTRY VESTIBULE, ALL WALLS OF INSET AREA CEDAR SHAKE SIDING AND CEDAR TRIM STAINED TO MATCH ROOFING FINISH CEDAR SHAKE SIDING AND CEDAR TRIM STAINED TO MATCH ROOFING FINISH THIN BRICK VENEER AT CHIMNEYS, TYP. standard red brick siding, typ INCLUDE PLANTER BOX SOLDIER COURSE, TYP. WINDOWS, PELLA ARCHITECT SERIES, IRON ORE EXT. CLADDING, TYP. 14" TJI W/ 3/4" SUBFLOOR 14" TJI W/ 3/4" SUBFLOOR & 2x6 sill plate 1x4 frieze board 1x6 frieze board 1X4 FRIEZE BOARD AT DORMERS 5" LIMESTONE TRIM, RAISED PROFILE 5" LIMESTONE TRIM, RAISED PROFILE 5" LIMESTONE TRIM, RAISED PROFILE 5" LIMESTONE TRIM, RAISED PROFILE INCLUDE PLANTER BOX 5" LIMESTONE TRIM, RAISED PROFILE MAIN LEVEL 0" UPPER LEVEL 11'-4 1/4" T.O. PL - UPPER LEVEL 20'-5 3/4" ACTUAL GRADE TO BE DETERMINED ON SITE VERIFY ACTUAL NUMBER OF STEPS AND HEIGHTS w/ FINAL GRADE, TYP APPROX T.O. ROOF 33'-6 101/128" T.O. FOUNDATION -1'-4 1/4" T.O. PLATE 10'-1 1/2" 10:12 10:12 10:12 10:12 10:12 15:12 10:12 10:12 10:12 10:12 10:12 15:12 15 12 10 12 10 12 10 12 15 12 15 15 12 12 15 12 15 12 15 12 10 12 standard red brick siding, typ composite, slate shingle roofing, medium grey, exact finish tbd WINDOWS, BLACK ENDURACLAD FINISH ON EXTERIOR, SIMULATED DIVIDED LIGHT, PELLA HORSE WEATHERVANE ON CUPOLA 3'-1 1/2" 3'-1" 10:12 10:12 10:12 8:12 8:12 8:12 3.5:12 8:12 8:12 8:12 8:12 8:12 10 12 8 12 15 12 15 12 15 12 15 12 10 12 15 12 10 12 10 12 10 12 10 12 15 12 10 12 8 12 8 12 8 12 8 12 8 12 8 12 8 12 R8'-1 23/32" R8'-4 1/4" R8'-1 23/32" R8'-10 15/32" BARREL VAULT - METAL ROOFING BARREL VAULT - METAL ROOFING METAL ROOFING ASPHALT ROOFING WITH LOOK OF BLUE/GREY SLATE ROOF BRICK HEADER BRICK HEADER BRICK HEADER BRICK HEADER BRICK HEADER BRICK HEADER BRICK HEADER LIMESTONESILL SILL LIMESTONESILL SILL LIMESTONE LIMESTONE BRICK SOLIDIER BRICK HEADER COURSE AROUND PERIMETER OF WIN. THIN BRICK VENEER AT CHIMNEYS, TYP. standard red brick siding, CAP HALF HT. WALLS W/ LIMESTONE CAP, typ LIMESTONE SILL LIMESTONE SILL WINDOWS, PELLA ARCHITECT SERIES, IRON ORE EXT. CLADDING, TYP. 15:12 10x10 WOOD COLUMNS, STAINED TO SUPPORT ROOF ABOVE, TYP. DRAWING NUMBER: TH 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 SCALE THIS DRAWING, IN FEET EMILY 736 HANOVER PL. SUITE #100F CARMEL, IN 46032 PH. 317.408.4853 FAX 317.257.7855 2/22/18 EMILY ARCH. CHANGE ORDER #1 3/16/18 EMILY PERMIT / BUILD SET 3/16/2018 2:44:54 PM Carmel, IN 46032 1095 Laurelwood FRONT & REAR ELEVATIONS 1 STOUGHTON RESIDENCE (Lot 61 - Laurelwood) 12/28/17 ARCHITECTURAL PERMIT-BUILD SET · FLAT SOFFIT AT PERIMETER OF HOUSE UNLESS NOTED OTHERWISE. · VERIFY ALL WDW & DR ROUGH OPNGS W/ MFR SPECS. · LOCATE ALL PLUMBING STACKS BEYOND THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER CODE. · ROOF VENTS SHOWN FOR LOCATION PURPOSE ONLY. · NUMBER OF ROOF VENTS TO BE DETERMINED BY BUILDER. GENERAL NOTES: !! ATTENTION !! NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER TO COORDINATE THE INSTALLATION OF ALL WATER PROOFING METHODS NECESSARY TO PROVIDE A WATER TIGHT BUILDING ENVELOPE. REFER TO MFR. INSTALLATION RECOMMENDATION FOR ALL SELECTED WATERPROOFING MATERIALS, FLASHING, SEALERS AND AD-MIX COMPONENTS THE FRAMING PLANS REPRESENTED IN THESE DRAWINGS ARE INTENDED TO ESTABLISH PROPOSED FRAMING MEMBER LOCATIONS, FRAMING MEMBER DEPTH, POTENTIAL BEARING LOCATIONS AND ELEVATIONS, AND IS IN NO WAY INTENDED OR TO BE INTERPRETED AS STRUCTURAL ENGINEERED DRAWINGS. THE CONTRACTOR (BUILDER)SHALL ENSURE THAT THE STRUCTURE CONFORMS TO THOSE STRAINS, LOADS, CONNECTIONS, AND STABILITY. REFER TO PLAN DISCLAIMER LOCATED ON THIS SHEET FOR ADDITIONAL STIPULATIONS AND REQUIREMENTS. Framing PLAN DISCLAIMER ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER 1/4" = 1'-0" FRONT ELEVATION 1/4" = 1'-0" REAR ELEVATION DATE REV. BY DESCRIPTION