HomeMy WebLinkAbout04110021 Building PlansC71 1/4" TEMPERED CLEAR GLASS CLEAR ANODIZED ALUM. SLIDING SASH TRANSACTION WINDOW w/ LOCK 8"44' ROUNDED EDGE PLASTIC LAMINATE ON PLYWOOD COUNTER w/ BRACKETS FFL 5ORROWED LITE 5L101 3 (4ELEVATION SCALE: 1 /2" =1' -0" A CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square 1" Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT As the authorized agent responsible for obtaining a permit or permits', I certify that these plans are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building ServicOOD nderst nd-that if it is determined that these plans are not identical, a STOP WORwi s d, as required under the Ordinances referenced below. Authoure Printed Name 'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zo ing Ordinance, Section 31.1 entitled "Violations and Penalties". i S:Permits /Forms/ Authen tSticker 11-01 Date REFLECTED CEILING PLAN SCALE: I/4 -I 0 1?1-dI 2 FLOOR PLAN SCALE: I/4"=1'-0" EXISTING WATER HEATER TO REMAIN —, I DEP 17'-4' 0 L EXISTING SCkLL v DOC*,' TO REMAIN EXISTING DOOR TO REMAIN EXISTING 200A --LEC. PANEIJ TO REM/,IN o - C1DEi IOL I T I ON PLAN SCALE: 114'1=11-011 EXITING MECH. UNI F TO REMAIN EXI'5TING FLUE THPU ROOF SN ������Q`�';si E po•y s 17a � 1 h10• 1 m STATE OF r ®�®sem ••tiNGIFNP:� A, . ®� .G C) 0 designed: SNP SKIN SENSE SALON / SPA TENNANT BUILDOUT checked: IFS 39 W MAIN STREET date: 10-01-04 CARMEL, INDIANA VERIFY CP'ITICAL DIMENSIONS WITHIN AND RELATED TO EXISTING BUILDING. DIMENSIONS AND CONDITIONS INDICATED WERE DETERMINED BY VISUAL SURVEY. DEMOLITION NOTES 1 REMOVE EXISTING CEILING AND GRID COMPLETE. EXISTING LIGHT FIXTURES SHALL BE PRESERVED FOR POSSIBLE REUSE. REMOVE ALL ELECTRICAL WIRE, CABLE, CONDUIT IN CEILING SERVING ANY TO -BE -DEMOLISHED EQUIPMENT. REMOVE EXISTING MECH. DUCTWORK, GRILLS TEC COMPLETE. 6> REMOVE DEPRESSION IN FLOOR. PREP FOR NEW FLOOR FINISH. REMOVE EXISTING WALL COMPLETE. INCLUDING ELEC., WOOD BASE AND CEILING MOLDING. REMOVE EXISTING FIXTURES AND CASEWORK. COMPLETE. CAP OFF UTILITIES AND PATCH WALLS / FLOOR FOR NEW FINISHES. EXISTING WALL FURRING (FRAMING AND SHEATHING) SHALL BE PATCHED AND REPAIRED AS REQUIRED. ALL FLOOR SURFACES SHALL BE LEVELED AND PREPED FOR NEW FLOOR FINISH. EXITING CARPET AND PAD SHALL BE REMOVED AND FLOOR PREPED FOR NEW CARPET. ALL EXISTING WOOD BASE, CEILING MOLD TO BE REMOVED. REMOVE EXISTING CLOSET DOOR AND FRAME COMPLETE FLAN NOTES I NEW 4'-0" BASE AND WALL CABINET w/ SINK. FURNISHED BY OWNER - INSTALLED BY GC. i2 30" PARTIAL HT. STUD WALL w/ GYP. BD. SHEATH FOR PLUMBING CHASE. j CAP w/ 5'-0"0-0" PLASTIC LAMINATE ON PLYWOOD COUNTER. 0 42" PARTIAL HT. STUD WALL w/ GYP. BD. SHEATH. CAP w/ 0-6"xl'-0" PLASTIC LAMINATE ON PLYWOOD COUNTER. 0 STUD WALL w/ GYP. BD. SHEATH. HVAC RETURN AIR DUCT TO CEILING REFLECTED CEILING PLAN NOTES PROVIDE 2'-0"x4'-0" ACOUSTICAL CEILING TILE SIMILAR TO USG RADAR WITH WHITE R" SUSPENDED CEILING GRID SIMILAR TO USG DONN X. --3-°-r DOOR SCHEDULE a TYPICAL DOOR LOUVERED BIFOLD DOOR AT CLOSET 102 I. ALL NEW DOORS TO BE 3'-0"x7'-0" PRE HUNG WOOD RESIDENTIAL TYPE PAINTABLE 6 PANEL DOORS. 2. PROVIDE LEVER TYPE, ANTIQUE BRASS FINISH DOOR HARDWARE WITH WALL MOUNTED DOOR STOPS 3. IN TOILET PROVIDE LEVER TYPE, ANTIQUE BRASS FINISH DOOR HARDWARE WITH PRIVACY LOCK'i AND WALL MOUNTED DOOR STOPS 4. ALL DOORS SHALL BE TRIMMED WITH PAINTED 4" WOOD TRIM. BOTH SIDES. WA i 1 4" WD. STUDS AT 16" O.C. WITH j 5/g" GYP. BD. EACH SIDES UP TO CEILING - PREP 4 PRIME READY FOR PAINT. (PAINT BY OWNER) O2 EXISTING WALL CONSTRUCTION. PATCH WALL SURFACE TO MATCH ADJACENT. O I L ET ROOM ACCESSORY SCSI ED U OI WALL MOUNTED GRAB BAR 1 1/2110 x! 36" LONG WITH SANITARY SAFETY I GRIP FINISH AND CONCEALED FASTENING n2 WALL MOUNTED GRAB BAR 1 1/2110 xi 4211 LONG WITH SANITARY SAFETY GRIP FINISH AND CONCEALED FASTENING O SURFACE MOUNTED TOILET PAPER HOLDER j' HERE CERTIFIED: vTHE SURFACE MOUNTED LIQUID SOAP DISPENSER t=ENI ACCEPTED ' THESE PANS HAVE E3 ; L R!lI ES Ti �E O 2'-8° W X 3'-011 MIRROR - CREPT. OF CCMt-a1UNi , r9 I t r �; SEP i 6ARNPi L r �,' ri•i:iTR `-�. t0� O PAPER TOWEL DISPENSER „r - r 1 yr,n _L TREY h,, ir_ . rt ate ; tTt t O7 ROBE HOOK �1; .�":�T Tom? ' FOCAL 's« 0 .l Y.. „� ii'i1 is � } REGULATIONS O;- r r O8 ADA TOILET FIXTURE BY GC I'TY OF CARMELI CL`Y TOWNSHIP, HIP, I t�+ANa C Oq ADA SINK FIXTURE BY GC ALL ACCESSMIES FURNIS14ED BY OWNER - INSTALLED BY GC scale: I sHIrr 1/4'1=1'-0" 0 4' B' I, A 2 GRAPHIC SCALE T FLOORS WAILS CEILINGS FC!No. ROOM NAME FLOORS BASE NORTH EAST SOUTH WEST CEILING CEILING HEIGHT REMARKS 1011 103-I0q ALL ROOMS SHEET VINYL 4" VINYL BASE PAINT PAINT PAINT PAINT 2x4 ACST 8'-2" EXISTING WATER HEATER TO REMAIN —, I DEP 17'-4' 0 L EXISTING SCkLL v DOC*,' TO REMAIN EXISTING DOOR TO REMAIN EXISTING 200A --LEC. PANEIJ TO REM/,IN o - C1DEi IOL I T I ON PLAN SCALE: 114'1=11-011 EXITING MECH. UNI F TO REMAIN EXI'5TING FLUE THPU ROOF SN ������Q`�';si E po•y s 17a � 1 h10• 1 m STATE OF r ®�®sem ••tiNGIFNP:� A, . ®� .G C) 0 designed: SNP SKIN SENSE SALON / SPA TENNANT BUILDOUT checked: IFS 39 W MAIN STREET date: 10-01-04 CARMEL, INDIANA VERIFY CP'ITICAL DIMENSIONS WITHIN AND RELATED TO EXISTING BUILDING. DIMENSIONS AND CONDITIONS INDICATED WERE DETERMINED BY VISUAL SURVEY. DEMOLITION NOTES 1 REMOVE EXISTING CEILING AND GRID COMPLETE. EXISTING LIGHT FIXTURES SHALL BE PRESERVED FOR POSSIBLE REUSE. REMOVE ALL ELECTRICAL WIRE, CABLE, CONDUIT IN CEILING SERVING ANY TO -BE -DEMOLISHED EQUIPMENT. REMOVE EXISTING MECH. DUCTWORK, GRILLS TEC COMPLETE. 6> REMOVE DEPRESSION IN FLOOR. PREP FOR NEW FLOOR FINISH. REMOVE EXISTING WALL COMPLETE. INCLUDING ELEC., WOOD BASE AND CEILING MOLDING. REMOVE EXISTING FIXTURES AND CASEWORK. COMPLETE. CAP OFF UTILITIES AND PATCH WALLS / FLOOR FOR NEW FINISHES. EXISTING WALL FURRING (FRAMING AND SHEATHING) SHALL BE PATCHED AND REPAIRED AS REQUIRED. ALL FLOOR SURFACES SHALL BE LEVELED AND PREPED FOR NEW FLOOR FINISH. EXITING CARPET AND PAD SHALL BE REMOVED AND FLOOR PREPED FOR NEW CARPET. ALL EXISTING WOOD BASE, CEILING MOLD TO BE REMOVED. REMOVE EXISTING CLOSET DOOR AND FRAME COMPLETE FLAN NOTES I NEW 4'-0" BASE AND WALL CABINET w/ SINK. FURNISHED BY OWNER - INSTALLED BY GC. i2 30" PARTIAL HT. STUD WALL w/ GYP. BD. SHEATH FOR PLUMBING CHASE. j CAP w/ 5'-0"0-0" PLASTIC LAMINATE ON PLYWOOD COUNTER. 0 42" PARTIAL HT. STUD WALL w/ GYP. BD. SHEATH. CAP w/ 0-6"xl'-0" PLASTIC LAMINATE ON PLYWOOD COUNTER. 0 STUD WALL w/ GYP. BD. SHEATH. HVAC RETURN AIR DUCT TO CEILING REFLECTED CEILING PLAN NOTES PROVIDE 2'-0"x4'-0" ACOUSTICAL CEILING TILE SIMILAR TO USG RADAR WITH WHITE R" SUSPENDED CEILING GRID SIMILAR TO USG DONN X. --3-°-r DOOR SCHEDULE a TYPICAL DOOR LOUVERED BIFOLD DOOR AT CLOSET 102 I. ALL NEW DOORS TO BE 3'-0"x7'-0" PRE HUNG WOOD RESIDENTIAL TYPE PAINTABLE 6 PANEL DOORS. 2. PROVIDE LEVER TYPE, ANTIQUE BRASS FINISH DOOR HARDWARE WITH WALL MOUNTED DOOR STOPS 3. IN TOILET PROVIDE LEVER TYPE, ANTIQUE BRASS FINISH DOOR HARDWARE WITH PRIVACY LOCK'i AND WALL MOUNTED DOOR STOPS 4. ALL DOORS SHALL BE TRIMMED WITH PAINTED 4" WOOD TRIM. BOTH SIDES. WA i 1 4" WD. STUDS AT 16" O.C. WITH j 5/g" GYP. BD. EACH SIDES UP TO CEILING - PREP 4 PRIME READY FOR PAINT. (PAINT BY OWNER) O2 EXISTING WALL CONSTRUCTION. PATCH WALL SURFACE TO MATCH ADJACENT. O I L ET ROOM ACCESSORY SCSI ED U OI WALL MOUNTED GRAB BAR 1 1/2110 x! 36" LONG WITH SANITARY SAFETY I GRIP FINISH AND CONCEALED FASTENING n2 WALL MOUNTED GRAB BAR 1 1/2110 xi 4211 LONG WITH SANITARY SAFETY GRIP FINISH AND CONCEALED FASTENING O SURFACE MOUNTED TOILET PAPER HOLDER j' HERE CERTIFIED: vTHE SURFACE MOUNTED LIQUID SOAP DISPENSER t=ENI ACCEPTED ' THESE PANS HAVE E3 ; L R!lI ES Ti �E O 2'-8° W X 3'-011 MIRROR - CREPT. OF CCMt-a1UNi , r9 I t r �; SEP i 6ARNPi L r �,' ri•i:iTR `-�. t0� O PAPER TOWEL DISPENSER „r - r 1 yr,n _L TREY h,, ir_ . rt ate ; tTt t O7 ROBE HOOK �1; .�":�T Tom? ' FOCAL 's« 0 .l Y.. „� ii'i1 is � } REGULATIONS O;- r r O8 ADA TOILET FIXTURE BY GC I'TY OF CARMELI CL`Y TOWNSHIP, HIP, I t�+ANa C Oq ADA SINK FIXTURE BY GC ALL ACCESSMIES FURNIS14ED BY OWNER - INSTALLED BY GC scale: I sHIrr 1/4'1=1'-0" 0 4' B' I, A 2 GRAPHIC SCALE T I. ALL WORK SHALL COMPLY WITH THE MOST RECENT REVISION OF ALL GOVERNING FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, AND CODES, INCLUDING BUT NOT LIMITED TO THE UNIFORM BUILDING CODE, UNIFORM PLUMBING CODE (IcR7 EDITION), WITH INDIANA AMENDMENCE AND ALL CODES ADOPTED BY REFERENCE BY THE INDIANA DEPARTMENT OF FIRE AND BUILDING SERVICES. 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF REGULATORY AGENCIES AND AUTHORITIES HAVING JURISDICTION, INCLUDING BUT NOT LIMITED TO LOCAL BUILDING INSPECTORS, OSHA, FM, AND SERVING UTILITIES. 3. ALL WORK SHALL COMPLY WITH STANDARDS REFERENCED IN THE SPECIFICATIONS AND ELSEWHERE ON THE DRAWINGS, INCLUDING BUT NOT LIMITED TO NFPA, AND RECOGNIZED INDUSTRY STANDARDS. MANUFACTURERS' INSTALLATION INSTRUCTIONS SHALL BE CONSIDERED A REFERENCED STANDARD. 4. DRAWINGS ARE SCHEMATIC IN NATURE. REFER TO THE SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS. 5. IF THE DRAWINGS, SPECIFICATIONS, CODES, REFERENCED STANDARDS, AND/OR REQUIREMENTS IMPOSED BY AUTHORITIES HAVING JURISDICTION ARE IN CONFLICT, THE CONTRACTOR SHALL BE LIABLE FOR MEETING THE MOST STRINGENT REQUIREMENT. (o. THE PC SHALL COOPERATE WITH OTHER TRADES TO PREVENT PROJECT DELAYS AND REWORK. 7. SPECIFIC MODEL NUMBERS LISTED ON DRAWINGS AND IN SPECIFICATIONS ARE BASIS OF DESIGN AND ARE LISTED FOR REFERENCE PURPOSES. OTHER MANUFACTURERS AND MODELS MAY BE ACCEPTABLE AS SET FORTH IN THE SPECIFICATIONS. THE CONTRACTOR 514ALL BE RESPONSIBLE FOR ALL ADDITIONAL WORK RESULTING FROM INSTALLATION OF EQUIPMENT NOT LISTED AS BASIS OF DESIGN. 8. CONTRACTOR SHALL CONFIRM THAT EQUIPMENT WILL FIT INTO THE SPACE PROVIDED WHILE ALLOWING ADEQUATE SERVICE AND OPERATIONAL CLEARANCES PRIOR TO INSTALLATION. 9. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT SHOWN ON THE DRAWINGS UNLESS NOTED OTHERWISE. 10. ALL EQUIPMENT SHALL BE COMPLETELY INSTALLED TESTED, ADJUSTED AND DEMONSTRATED TO BEI WORKING CONDITION PRIOR TO ACCEPTANCE BY THE OWNER. 11. THE CONTRACTOR SHALL PROVIDE A NON -PRO -RATED WARRANTY ON WORKMANSHIP, EQUIPMENT, AND MATERIALS FOR A PERIOD OF TWELVE (12) MONTHS AFTER THE DATE OF SUBSTANTIAL COMPLETION UNLESS ANOTHER WARRANTY PERIOD 15 SPECIFIED ELSEWHERE ON THE DRAWINGS OR IN THE SPECIFICATIONS. 14. COORDINATE ALL FLOOR OPENINGS, EXACT LOCATION AND SIZE OF ALL WALL, CEILING OR ROOF PENETRATIONS REQUIRED FOR PIPING WITH G.C. AND OTHER TRADES, GENERAL NOTES I. SEE SHEET MP2.1 FOR PLUMBING GENERAL NOTES, LEGEND OF SYMBOLS, AND ABBREVIATIONS. 2. SEE SHEET MP2.1 FOR SANITARY AND VENT SIZES. 3. ALL UNUSED EXISTING PLUMBING CONNECTIONS SHALL BE CAPPED OFF BEHIND DRYWALL SURFACES. 4. ALL PLUMBING SHALL BE ABOVE GRADE WHEREVER POSSIBLE. KEYED NOTES lO WATER CLOSET: CONNECT 4" SANITARY, 2" COLD WATER LINE AND 2" VENT LINE. Q LAVATORY: PROVIDE 1/2" COLD WATER, 1/2" HOT WATER, 1 1/4" VENT AND 1 1/2" SANITARY. Q RESIDENTIAL CLOTHES WASHER CONNECTION." HOT AND COLR WATER, 2" SANITARY AND 11" VENT. ® 4" SAN RISER TO CONNECT TO EXISTING SANITARY SYSTEM FIELD VERIFY FOR EXACT LOCATION AND INVERT. 0 CONNECT NEW I" CW PIPING TO EXISTING WATER SERVICE. © CONNECT 2 " VENT TO NEAREST EXISTING 2�' OR LARGER VENT LINE CAPABLE OF SERVING NEEW AND EXISTING FIXTURES PER CURRENT INDIANA PLUMBING CODE OR EXTEND 21" VENT UP AND PROVIDE 4" VT9. O CONNECT I" NOT WATER LINE TO EXISTING NOT WATER LINE AT EXISTING WATER NEATER. EXISTING GAS METER CLOSETS 7 itIQ's BREAKROt)M/ UTILITY T- it 108_1 I�LAV -1 I "HW4 I� CW \ I I 1n � 2 ,I TREATMENT O2 LAV -1 LAV -1 CW ' 'I I ' TREATMENT ' 304 Ii I I� I 2n I� r I� O LAV -1 CC� ' CC 5ULTA ION 103 t RECEPTION 101 WAITING 100 )�SCLAFE 0 0 Lu z J 4 z H N X Lu M CORRIDOR 300 MECH. CLOSET 102 70 WATER CLOSET - (WC- I) COUNTER STAINLESS STEEL SINK - (LAV -I)® WALL HUNG LAVATORY - (LAV -2) FO FIXTURE TYPE CW NW SAN VENT FLOOR DRAIN / / 2" / LAVATORY 1/2" 1/2" 1 1/4" 1 1/2" WATER CLOSET 1/2" / 4" 2" CLOTHES WASHER CONNECTION 1/2" 1/2" 2" I 1 1/2" FIXTURE TYPE WSFU DFU CW Hyl/Hyp EACH COMB. 5 LAVATORY 1 1 1.5 1 WATER CLOSET 5 / 5 5.0 WATER CLOSET 3 3 4 4.0 FIXTURE TYPE FLOOR DRAIN LAVATORY WATER CLOSET WASHER TOTALS TOTAL TOTAL TOTAL COUNT I WSFU I DFU PIPING SYMBOL LEGEND PIPE SYSTEMS EACH EACH 0 0 0 5 7.5 5 I 5 5 i 4 4 8 16.5 14 PIPING SYMBOL LEGEND PIPE SYSTEMS DIRECTION OF FLOW - - - DOMESTIC CITY WATER DOMESTIC HOT WATER SANITARY SEWER SANITARY VENT GAS._. SCALE: NTS ISER I501 IETRIC u V desiped: SNP checked: IFS date: 10-01-04 DRYER FLEX DUCT TO EXTERIOR WALL w/ VENT WALL CAP MECH. CLOSE - r o�oo>�RAN K SAFh%- � •®s, �Q No it 70 d o STATE OF i HVAC PLAN ��, /NpIA�A••:�,<�� 1 SCALE: 114"4-011 6®°d��l�CHI��G�aaa d�a.,3•�i:il SKIN SENSE SALON / SPA TENNANT BUILDOUT 39 W MAIN STREET CARMEL, INDIANA 1. ALL WORK SHALL COMPLY WITH THE MOST RECENT REVISION OF ALL GOVERNING FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, AND CODES, INCLUDING BUT NOT LIMITED TO THE INDIANA BUILDING CODE, INDIANA MECHANICAL CODE, INDIANA PLUMBING CODE, INDIANA ENERGY CONSERVATION CODE AND ALL CODES ADOPTED BY REFERENCE BY THE INDIANA DEPARTMENT OF FIRE AND BUILDING SERVICES. 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF REGULATORY AGENCIES AND AUTHORITIES HAVING JURISDICTION, INCLUDING BUT NOT LIMITED TO LOCAL BUILDING INSPECTORS, OSHA, FM, AND SERVING UTILITIES. 3. ALL WORK SHALL COMPLY WITH STANDARDS REFERENCED IN THE SPECIFICATIONS AND ELSEWHERE ON THE DRAWINGS, INCLUDING BUT NOT LIMITED TO NFPA, AND RECOGNIZED INDUSTRY STANDARDS. MANUFACTURERS' INSTALLATION INSTRUCTIONS SHALL BE CONSIDERED A REFERENCED STANDARD, 4. DRAWINGS ARE SCHEMATIC IN NATURE. REFER TO THE SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS. 5. IF THE DRAWINGS, SPECIFICATIONS, CODES, REFERENCED STANDARDS, AND/OR REQUIREMENTS IMPOSED BY AUTHORITIES HAVING JURISDICTION ARE IN CONFLICT, THE CONTRACTOR SHALL BE LIABLE FOR MEETING THE MOST STRINGENT REQUIREMENT. 6. THE MC SHALL COOPERATE WITH OTHER TRADES TO PREVENT PROJECT DELAYS AND REWORK. 7. SPECIFIC MODEL NUMBERS LISTED ON DRAWINGS AND IN SPECIFICATIONS ARE BA515 OF DESIGN AND ARE LISTED FOR REFERENCE PURPOSES. OTHER MANUFACTURERS AND MODELS MAY BE ACCEPTABLE AS SET FORTH IN THE SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ADDITIONAL WORK RESULTING FROM INSTALLATION OF EQUIPMENT NOT LISTED AS BASIS OF DESIGN. 8. CONTRACTOR SHALL CONFIRM THAT EQUIPMENT WILL FIT INTO THE SPACE PROVIDED WHILE ALLOWING ADEQUATE SERVICE AND OPERATIONAL CLEARANCES PRIOR TO INSTALLATION. 9. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT SHOWN ON THE DRAWINGS UNLESS NOTED OTHERWISE. 10. ALL EQUIPMENT SHALL BE COMPLETELY INSTALLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE IN WORKING CONDITION PRIOR TO ACCEPTANCE BY THE OWNER. 11. THE CONTRACTOR SHALL PROVIDE A NON -PRO -RATED WARRANTY ON WORKMANSHIP, EQUIPMENT, AND MATERIALS FOR A PERIOD OF TWELVE (12) MONTHS AFTER THE DATE OF SUBSTANTIAL COMPLETION UNLESS ANOTHER WARRANTY PERIOD IS SPECIFIED ELSEWHERE ON THE DRAWINGS OR IN THE SPECIFICATIONS. 12. PROVIDE VOLUME DAMPER AT EACH BRANCH DUCT SERVING A DIFFUSER OR GRILL, LOCATE DAMPER IN RIGID DUCT. 13. COORDINATE ACTUAL DUCT ROUTING WITH PIPING, LIGHTS AND BUILDING STRUCTURE. 14. COORDINATE ALL FLOOR OPENINGS WITH GENERAL CONTRACTOR 15. COORDINATE EXACT LOCATION AND SIZE OF ALL WALL, CEILING OR ROOF PENETRATIONS ,REQUIRED FOR DUCT OR MEC14ANICAL EQUIPMENT WITH OTHER TRADES. 16. FOR ALL ROUGH OPENINGS, OMIT DRYWALL TO PROVIDE OPENING IN WALL ABOVE CEILING PER SIZES SHOWN ON PLANS (EX. 120" X 24" R.O.). COVER OPENING ON ONE SIDE WITH 1/2" MESH , GALVANIZED HARDWARE CLOTH (STUDS SHALL EXTEND THROUGH OPENING TO DECK). LL ROUND FLEXIBLE DUCT CONNECTION CEILING GRILLE, EXHAUST, RETURN a OR TRANSFER THERMOSTAT 0 CONNECT ALL DIFFUSERS AND RETURNS TO EXISTING HVAC UNIT w.MIN 8" FLEX DUCT. ABOVE CEILING Ville: SHEET 1/4"=1'-0" 0 4' 8' ___-I M P 2 • GRAPHIC SCALE a a 0 I I I LIGHT FIXTURE SCHEDULE GENERAL NUTES : PLECTRICAL TYPE DESCRIPTION MANUFACTURER SYMBOL 2'X4' RECESSED FLUORESCENT STATIC TROFFER FOR RECESSING IN A SUSPENDED I. DAY-BRITE CAT. NO. 2 DP G 3 32-F5 12 120-1/21-EB-F32T8 WALL ACOUSTIC CEILING GRID WITH Al2 PATTERN, .125" NOMINAL THICKNESS VIRGIN ACRYLIC 2. HOLOP14ANE I MAGNETICHOLDER _..__ DOOR __..___.........._..__.._...._....___.._... LENS, BAKED -ON WHITE POWDER COATING, THREE (3) F32T8 TRI -PHOSPHOR LAMPS, 3. HUBBELL A ONE (1) ADVANCE CENTIUM OR MOTOROLA CLASS P, HPF, CBM CERTIFIED, 120V 4. LITHONIA MOTOR CONTROL CENTER ELECTRONIC BALLASTS AND U.L. LISTING. 5. MET'ALUX SMOKE DETECTOR (P -E W/ DUCT PROBE SUPPLY SIDE) INCANDESCENT FIX'T'URE 6. COLUMBIA MAIN DISTRIBUTION SWITCHBOARD EXIT LIGHTING UNIT, 6" RED LETTERS WITH FULL 3/4" LETTER STROKE EVENLY 1. DUAL LITE EXCALIBUR SERIES SMOKE DETECTOR (P -E W/ DUCT PROBE RETURN 51DE ILLUMINATED BY RED LIGHT EMITTING DIODES, BLACK BODY, BRUSHED ALUMINUM 2. EMERGI-LITE ELECTRICAL DISTRIBUTION PANEL50ARD FACE, 120V AC POWER SOURCE, SELF-DIAGNOSTIC TESTING, NICKLE-CADMIUM 3. HUBBELL INFRARED BEAM SMOKE DETECTOR BATTERY BACK-UP AND U.L. LISTING. NUMBER OF FACES AND MOUNTING A5 4. LITHONIA CAT NO. LE 5 1 R 120 ELN LIGHTING OR POWER PANEL AS NOTED REQUIRED, REFER TO DRAWINGS. 5. SURE-LITE5 I FIRE ALARM PULL STATION DOWNLIGHT .____.._..__...._..___..____.._......_..__........__.._.._..____..__....__-..____.._....__.._.._______.._..____.._............_........... .......... N.I.D. DOWNLIGHT H.I.D. POLE MTD. FLOODLIGHT W/No. of heads as indicated 6. PRESCOLITE PANEL AS NOTED ._____.___..------------- ------------------------------------ .___.... _...... ___.... ........___...... ....____.._________....__.._.... TRANSFORMER .......____ .............._..._.....___..__......_.._. DISCONNECT SWITCH -FUSED EXISTING FIXTURE DISCONNECT SWITCH - NON-FUSED C 0-0 ELECTRICAL SYMBOLS _ MOUNTING qp RR DESCRIPTION SYMBOL DESCRIPTION CEILING WALL FLOOR __ ____.._.._____________ _-------------__.-_-___ _ I MAGNETICHOLDER _..__ DOOR __..___.........._..__.._...._....___.._... ____ ®SD FLUORESCENT FIXTURE I SMOKE DETECTOR (PHOTO -ELECTRIC) MCC DD MOTOR CONTROL CENTER O Q SMOKE DETECTOR (P -E W/ DUCT PROBE SUPPLY SIDE) INCANDESCENT FIX'T'URE MDS MAIN DISTRIBUTION SWITCHBOARD Q Q SMOKE DETECTOR (P -E W/ DUCT PROBE RETURN 51DE H.I.D. FIXTURE © ELECTRICAL DISTRIBUTION PANEL50ARD INFRARED BEAM SMOKE DETECTOR FLUORESCENT DOWNLIGHT ` LIGHTING OR POWER PANEL AS NOTED po•INCANDESCENT _____..______..____..___.._.._...._......_ Q .............................._..___..____........___ I FIRE ALARM PULL STATION DOWNLIGHT .____.._..__...._..___..____.._......_..__........__.._.._..____..__....__-..____.._....__.._.._______.._..____.._............_........... .......... N.I.D. DOWNLIGHT H.I.D. POLE MTD. FLOODLIGHT W/No. of heads as indicated 6 ..... __............. ------- ET 30A.3P NEMA 3R Q320A FtiSE PANEL AS NOTED ._____.___..------------- ------------------------------------ .___.... _...... ___.... ........___...... ....____.._________....__.._.... TRANSFORMER .......____ .............._..._.....___..__......_.._. DISCONNECT SWITCH -FUSED lys0A.3P,NEMA 3R DISCONNECT SWITCH - NON-FUSED £ FIRE ALARM HORN / LIGHT COMBINATION 0-0 H.I.D. POLE LIGHT W/ No. of heads as indicated Q LIGHTING CONTACTOR ( € FIRE ALARM 5TR05E LIGHT RECI zsm+piv H.I.D. FLOODLIGHT ® CONTROL RELAY ................_...._-...._.._. _.._.., 1 FIRE INDICATING LIGHT - ROTATING BEACON ■ H.I.D. BOLLARD LIGHT 0 MAGNETIC MOTOR STARTER __. .. .. _..... ......_._.__......a»........_...._.............._._............._..........._...............__.................... ... € I FIRE CHIME / LIGHT COMBINATION ' ° $2P _ _ Lt'I A EXIT LIGHT - LINE INDICATES FACE ARROW INDICATES FACE WITH DIRECTION OF TRAVEL ALL EXIT LIGHTS TO BE TYPE " E "ENEMA SWITCH - SINGLE POLE LOWERCASE LETTER INDICATES FIXTURES/LAMPS CONTROLLED (TYPICAL) __.__._.._............___-.._ ....... _.. SWITCH - TWO POLE, SINGLE THROW 0j COMBINATION STARTER * DISC. 5W. 30q, 30.4E0V 1 m __........____..__..________..__..____..___..-.-.........._____.._____..__.______ 01 ......... _.... _..------ _.. _._ _.____...__..__ _._. 0jP CIRCUIT BREAKER ENCLOSURE CAPACITOR 51ZE AS NOTED ____....___-----_____.._-_....___-_______-_..__..__.__..__......_......_......._____..________.._..__..__...._.._.._..__ MANUAL STARTER W/ OVERLOADS _..____ _ _ _ _ .._.............__ .__ ..__..._ ._..--------- MANUAL STARTER W/ PILOTLIG14T PS $3 © SWITCH - THREE WAY ( REMOTE INDICATING ALARM LAMP EMERGENCY GENERATOR s $4 SWITCH - FOUR WAY ATS AUTOMATIC TRANSFER SWITCH $R $PL SWITCH WITH PILOT LIGHT - SINGLE POLE ��-'�.� CONDUIT -CONGEALED IN CEILING OR WALL $o 00 DIMMER SWITCH WATTAGE AS INDICATED �- CONDUIT -CONGEALED IN OR BELOW FLOOR ______..___________ ___....___.........._____.._._........_......_ $K _...._..__.....__......_..........._......__.._..____ $K3KEY .._................ .... $1• ......................_.._........__...._.._...._____ $M _ ..__. .... _.__..._ _ _._. KEY SWITCH - SINGLE POLE __________...___..___....___..........__....__ _.._......___....____.._......___..____........_......___.._.__.._....__.._.._....___.._..__...........__.._.._________...._________.........._ SWITCH - THREE WAY ...._ _-----... _..._ ._ ---.._.__...._-..W...-__• _..._-._._-.__._.._-.............. _.... _...__...... .... TIMER SWITCH __.._.._......______..__.._.._...._..___...___.._.._.._..__...... _.._---------- ............... _..________.._.............._............. ....... _.... SWITCH - MOMENTARY CONTACT .............._..__...._...._____..._...___..__ _ .. ._ ._ __.._._ .___ _ _ _ _._ .__ __ .._.._...._.._..____......____.._.._______..___......_....__......__.........._.._____..__..__ CONDUIT -UNDERGROUND _..___..._________.___________.___________.._.._.._..__.._...._..___..__.........._.._.._........_____..__..._..__.._...._....__. CONDUIT -EXPOSED _... __ . _.._......_.__...__........._..._........ _......... _....- ... _..._._. _... DIRECT BURIED CABLE ___.._._..__-----___ ______.__._______..--------.--.._---......._........____.._........_..__......_...._.........._....._.._ INDICATES HOME RUN M DUPLEX RECEPTACLE ��� INDICATES PHASE OR HOT CONDUCTOR DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER INDICATES GROUNDED OR NEUTRAL CONDUCTOR SINGLE RECEPTACLE MOUNTED ABOVE COUNTER INDICATES GROUNDING CONDUCTOR M DOUBLE DUPLEX RECEPTACLE INDICATES NUMBER OF CIRCUITS IN RUN ® _._.____......_. ® vs _._..._._._. - . __.__....._.... GFI ® _._._-.._ ._..._. SPECIAL RECEPTACLE OR OUTLET AS NOTED .............._.......... _..__..__.._.._.---__.._....____....__..____.._..__......__.._......__.... SAFETY RECEPTACLE _._____. __..._......____.__.___..____._..__._. __.. ___._...____..........._...__......__...__._....... WEATHERPROOF DUPLEX RECEPTACLE .................. .....__.._______.._......___....___..__.._..-..___..__...._.._.._..__..__..___ ��• ._._..__._..___..____.._ __.___._ _....._._._ ___.__...__ /��, INDICATES SWITCHED AND UNSWITCHED CIRCUITS CONDUIT TURNED UP CONDUIT TURNED DOWN ___._ __ _ CONDUIT STUBBED OUT AND CAPPED =0= EXP EXP MEXP EXPLOSION PROOF RECEPTACLE OR OUTLET D PUSHBUTTON STATION �GFI DUPLEX G.F.C.I. TYPE RECEPTACLE PUSHBUTTON STATION WITH PILOT LIGHT SIG 4PIG MIG ISOLATED GROUND RECEPTACLE TC TIME CLOCK MULTI -OUTLET STRIP - TYPE AS NOTED + ROUGH -IN t FINAL CONNECTION ® m (? ISI Q JUNCTION BOX "V MOTOR ___._ __.._..__....__..___ © .._........_...._...._....___...._ ..._.._........___..____..___........______......_.._............___...._.._........__.._....________.._....__..__.._.._...._ PULL BOX SIZE AS NOTED ...... ._........ _ .._..... _ ._. _ _ .__....._.. _ r ._..__...._......_ .............___ .......... ___..---___...._...._....____......_......__........_.._......_..___ ON ._._.._....._.._..--__...__ - _ _ __ ._..._.__ . __ _..___._ 00 _..__..._..__..__..._.._---_.........._......_.._._...._____......_ *-ill STEP DOWN OR CONTROL POWER TRANSFORMER __.__ __ ___ _ _ - __.. _._.... .__......_........ ..._.._.._...._.... _.... _..._. ELECTRIC DOOR OPERATOR ______.__---_______---------____..___-------------------.__---...._........_....____.._......_ ............................... GROUNDING ELECTRODE OR GROUND ROD • GROUND CONNECTION GROUNDING TRIANGLE - REFER TO DETAILS FOR SIZE FIRE ALARM SYMBOLS ®RR qp RR HEAT DETECTOR (RATE OF RISE) �� TERMINAL CABINET _..---------- j TERMINAL BACKBOARD -4'X WX 3/4" PLYWOOD DOOR HOLDER ROUGH -IN (IN DOOR CLOSER) 0135 IQ 135- ':. ! NEAT DETECTOR (FIXED TEMPERATURE) ____.._.._______...._..__.._...._.._...._......._................_____..__!__.._...._.._..___..__....___....___ _..___...._....______________»_»_..____._........_..____.____....__.._..__..____.._..____.._____..___..__---_---------------------------- SINGLE DATA OUTLET __ ____.._.._____________ _-------------__.-_-___ _ I MAGNETICHOLDER _..__ DOOR __..___.........._..__.._...._....___.._... ____ ®SD iQ SD I SMOKE DETECTOR (PHOTO -ELECTRIC) 'TELEPHONE AND DATA OUTLET DD ; DIGITAL DIALER { I OF - SMOKE DETECTOR (P -E W/ DUCT PROBE SUPPLY SIDE) FIRE ALARM REMOTE ANNUNCIATOR SMOKE DETECTOR (P -E W/ DUCT PROBE RETURN 51DE FAGA I I FIRE ALARM GRAPHIC REMOTE ANNUNCIATOR INFRARED BEAM SMOKE DETECTOR ITFA-C-P-1 I FIRE ALARM CONTROL PANEL ❑F I FIRE ALARM PULL STATION FAA I FIRE ALARM CONTROL PANEL AND ANNUNCIATOR QQ F F £ FIRE ALARM HORN / LIGHT COMBINATION Off I WATER FLOW SWITCH QQ F I I]4 F ( € FIRE ALARM 5TR05E LIGHT zsm+piv I P.I.V. _ . ____�.._____..__. --------- ..__......_.... ® ..__...._....__ £ Q ................_...._-...._.._. _.._.., 1 FIRE INDICATING LIGHT - ROTATING BEACON Qsg i SUPERVISORY VALVE SWITCH _._...._ .............._........b --._....................._.........__e_.................. e $ __. .. .. _..... ......_._.__......a»........_...._.............._._............._..........._...............__.................... ... € I FIRE CHIME / LIGHT COMBINATION _ _ Lt'I A .._....—.__-_ ; ALARM CHECK VALVE SWITCH CQ F ICQ F i ELECTRONIC "WOOP" PS 's PRE55URE SWITCH © Q ( REMOTE INDICATING ALARM LAMP s SPRINKLER ALARM BELL F ; FIRE ALARM BELL $R REMOTE RESET SWITCH TELECOMMUNICATION SYSTEM SYMBOLS I _.._....__....__..___..__.._...I....... -INt I Q ............................ _= I SINGLE TELEPHONE OUTLET £.......__.. I DUAL TELEPHONE OUTLET �� TERMINAL CABINET _..---------- j TERMINAL BACKBOARD -4'X WX 3/4" PLYWOOD Q SINGLE DATA OUTLET FLOOR MOUNTED EIA TYPE RACK WITH DOORS I DUAL DATA OUTLET 'TELEPHONE AND DATA OUTLET I WALL MOUNTED EIA TYPE RACK { I 2 �O1��1_17 ALAN SCALE =1'-0" III designed: SNP checked IFS date: 10-01-04 EXISTING 200 A PANEL MECH. CLOSET (1!FLAN SKIN SENSE SALON / SPA TENNANT BUILDOUT 39 W MAIN STREET CARMEL, INDIANA 1. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES, LOCAL ORDINANCES AND INDUSTRY STANDARDS. 2. NATIONAL ELECTRIC CODE (NEC) AND NATIONAL ELECTRICAL CONTRACTOR ASSOCIATION (NECA) INSTALLATION STANDARDS SHALL BE CONSIDERED MINIMUM STANDARDS. 3. ALL INSIDE CONDUIT SHALL BE ELECTRICAL METALLIC TUBING (EMT) EXCEPT WHERE OTHERWISE NOTED. 4. ALL OUTSIDE CONDUIT SHALL BE GALVANIZED RIGID STEEL CONDUIT EXCEPT WHERE OTHERWISE NOTED. 5. MINIMUM ELECTRICAL CONDUIT SIZE SHALL BE 3/4", OTHER CONDUIT 51ZES ARE NOTED ON CONTRACT DOCUMENTS. G. PROPERLY SUPPORT ALL CONDUITS AND JUNCTION BOXES. 7. MINIMUM CONDUCTOR SIZE SHALL BE NUMBER 12 AWG. OTHER CONDUCTOR SIZES ARE NOTED ON CONTRACT DOCUMENTS. S. CONDUCTOR INSULATION SHALL BE THW, THWN OR THHN RATED AT 600 VOLTS, 75 DEGREES C FOR DRY LOCATIONS AND 75 DEGREES C FOR WET LOCATIONS. 9. CONDUCTORS SHALL BE SPLICED IN BOXES ONLY. 10. MOUNT ALL CONDUITS TO BOTTOM OF STEEL I -BEAMS, PURLINS, BAR JOISTS, OR ON UN15TRUT CHANNEL AND THREADED RODS. II. CONDUIT FILL SHALL NOT DEVIATE FROM THAT SHOWN ON CONTRACT DOCUMENTS. 12. INSTALL CONDUIT AT LOCATIONS SHOWN ON CONTRACT DOCUMENTS. CONDUIT IN THE SAME AREA SHALL BE ROUTED TOGETHER IN A PARALLEL, ORDERLY MANNER. 13. CONTRACTOR SHALL SUPPLY ALL NECE55ARY HANGERS AND/OR MOUNTING ACCESSORIES FOR LIGHTING FIXTURES. 14. ALL FLUORESCENT LENSES SHALL BE 1007. VIRGIN ACRYLIC EXCEPT WHERE OTHERWISE NOTED. 15. INSTALL I" CONDUIT AT EACH TELEPHONE AND DATA OUTLET AND STUB -UP ABOVE CEILING UNLESS OTHERWISE NOTED. 16. INSTALL GROUND WIRE IN ALL CIRCUITS. scale: 1/4"=1'-0" 0 4' 8' GRAPHIC SCALE E2.1 a I r I f`